ULAF2-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for ULAF2-MIB.
71
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
71 total| Object Name |
|---|
siemensCH OBJECT IDENTIFIER .1.3.6.1.4.1.1887 |
RFC1213-MIB Unknown .1.3.6.1.4.1.1887 |
lineintegrator OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1 |
ulaf2 OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1 |
proxyAgent OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.1 |
proxyAgtVers2 OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.1.2 |
agtSystem OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.1.2.1 |
agtSWVersionContains software version of Proxy Subagent.ro DisplayString .1.3.6.1.4.1.1887.1.1.1.2.1.1 |
agtDateLastPortChangeContains time when the connected device or the type of link of a device
equipment has changed.(Link Up and Down traps).ro INTEGER .1.3.6.1.4.1.1887.1.1.1.2.1.2 |
agtProxyFeatureFlagContains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed devicero OCTET STRING .1.3.6.1.4.1.1887.1.1.1.2.1.3 |
agtProxyAciSupportedIdentifies this device as Ulaf+ OMI SNMP towards
Access Integrator. Always returns 'FullAciSupport'ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1887.1.1.1.2.1.4 |
agtSerialPort OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.1.2.2 |
agtPortNumberThis object contains the number of available serial portsro INTEGER .1.3.6.1.4.1.1887.1.1.1.2.2.1 |
agtPortTable SEQUENCE OF AgtPortEntry .1.3.6.1.4.1.1887.1.1.1.2.2.2 |
agtPortEntry AgtPortEntry .1.3.6.1.4.1.1887.1.1.1.2.2.2.1 |
agtPortIndexThis object corresponds to the port number. Ports are
enumarated beginning with one.ro INTEGER .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.1 |
agtPortNameContains name of device filero DisplayString .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.2 |
agtPortConnectedThis object tells the agent, if the appropriate serial port
is used or not.rw Enumeration .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.3 |
agtConnectedDeviceThis object contains the name of the connected device (e.g OMIBG).ro DisplayString .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.4 |
agtPortTypeThis object describes if the port is a local RS232 serial port,
a locally installed serial port card or the port is a remote
port of a port serverro Enumeration .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.5 |
agtPortTypeNumberThis object contains the number of the serial port of the
appropriate port type defined in agtPortType.ro INTEGER .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.6 |
agtPortServerNameThis object contains a name to identify the port serverro DisplayString .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.7 |
agtPortStateThis variable shows in which reconnection state a port is.
The first two states refer to local serial ports or to
PortServer ports using the Digi RealPort drivers, the last
three states refer to PortServer ports using the
proprietory method of LineIntegrator.
1 UnopenedSerial Serial port, not opened
2 OpenedSerial Serial port, opened
3 ConnectingRemote Remote port, waiting for connection
4 OpenedRemote Remote port, opened
5 FailedRemote Remote port, connection failed
6 Disabled Port is disabled
7 Invalid Port entry is invalid (configuration file problem)
254 Unknown Unknown valuero Enumeration .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.8 |
agtPortDeviceFamilyThis variable shows which device family will be tried during
the auto-discovery phase.
1 Ulaf2 Ulaf-2 Devices (OMI, NAG) will be discovered
2 UlafPlus Ulaf+ Devices (OMI, XTU) will be discovered
3 Ulaf2AndPlus Ulaf-2 and Ulaf+ devices will be discovered
254 Unknown Unknown valuero Enumeration .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.9 |
agtPortTryingDeviceThis variable shows which device is currently being tried on the port.
If no answer is received during 5 seconds, the next device will be tried
1 Disabled The port has been disabled, no device will be tried
2 Invalid The port is invalid, no device will be tried
3 None No device is being tried at the moment
4 Omi Trying Ulaf-2 OMI
5 Nag Trying Ulaf-2 NAG Desktop
6 OmiPlus Trying Ulaf+ OMI
7 DesktopPlus Trying Ulaf+ Desktop
254 Unknown Unknown valuero Enumeration .1.3.6.1.4.1.1887.1.1.1.2.2.2.1.10 |
agtAlarmCountGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.1.2.3 |
agtAlarmCountThis object counts the number of Alarm traps
sent by this proxy since the last time the
variable has been read.ro INTEGER .1.3.6.1.4.1.1887.1.1.1.2.3.1 |
agtPortServerResetThis variable cannot be read (it returns unknown if read)
If reset(1) is written to it, the proxy tries to reset all
DigiInternational PortServers. It does not reset any other
manufacturer's port servers.
This step can be necessary, if a router between the proxy
and a PortServer has crashed and the PortServer keeps open
a stale connection to which the proxy can no longer connect.
Do not use this feature manually but use the option in the
LineIntegrator Menu in HP OpenView NNM.rw Enumeration .1.3.6.1.4.1.1887.1.1.1.2.4 |
device OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.3 |
deviceVers2 OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.3.2 |
deviceSystem OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.3.2.1 |
deviceSystemTable SEQUENCE OF DeviceSystemEntry .1.3.6.1.4.1.1887.1.1.3.2.1.1 |
deviceSystemEntry DeviceSystemEntry .1.3.6.1.4.1.1887.1.1.3.2.1.1.1 |
deviceSystemPortIndexThis object addresses the port of the proxy agent.ro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.1.1.1.1 |
deviceLinkNumberThis object contains the maximum number of supported line cardsro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.1.1.1.2 |
deviceSWVersionContains software version of device.ro DisplayString .1.3.6.1.4.1.1887.1.1.3.2.1.1.1.3 |
deviceExtAlarmThis object contains the external alarm of the OMI equipment.ro Enumeration .1.3.6.1.4.1.1887.1.1.3.2.1.1.1.4 |
deviceDateLastLinkChangeThis object contains the absolute date and time when the type
of link has changed its configuration.
(e.g. removing a line card).
(Link Up and Link Down Traps)ro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.1.1.1.5 |
deviceOmiFeatureFlagContains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed devicero OCTET STRING .1.3.6.1.4.1.1887.1.1.3.2.1.1.1.6 |
deviceLinks OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.3.2.2 |
deviceLinkTable SEQUENCE OF DeviceLinkEntry .1.3.6.1.4.1.1887.1.1.3.2.2.1 |
deviceLinkEntry DeviceLinkEntry .1.3.6.1.4.1.1887.1.1.3.2.2.1.1 |
devicePortIndexThis object addresses the port of the proxy agent.ro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.1 |
deviceLinkIndexThis object addresses the links.ro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.2 |
deviceLinkNameThis object contains the name of the inserted line card.
If no line card exists, the name is Unknown.ro DisplayString .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.3 |
deviceLinkAlarmThis object contains the collected alarms
It is used to convert alarm notifications
to SNMP traps.
Bits 0,1 and 2 are used for the Alarm Summary
Bit 5 is used to signify a loop state change of Ulaf-2 Desktop devices
Bit Alarm Description
0 UA Urgent alarm
1 NUA Non urgent alarm
2 AIS Alarm indication signal
3 unused
4 unused
5 loopback change (Ulaf-2)ro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.4 |
deviceLinkLocalLtNtIndicates whether the management system is connected to
an LT or an NT device.
1 LT Device is configured as LT
2 NT Device is configured as NT (NT local)
254 unknown value
255 unsupported variable for addressed devicero Enumeration .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.5 |
deviceLinkLocalIdContains the Firmware ID of the local device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.6 |
deviceLinkFarIdContains the Firmware ID of the far device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.7 |
deviceLinkNumReg1Indicates how many regenerators were detected in HDSL path 1.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported valuero Enumeration .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.8 |
deviceLinkNumReg2Indicates how many regenerators were detected in HDSL path 1.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported valuero Enumeration .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.9 |
deviceLinkLocalModulesGives a short summary of which modules are installed in the local
device. This variable is bit coded as follows:
Bit 0 G.703 Interface installed
Bit 1 Data Interface installed
Bit 2 Alarm Module installed
Bit 3 Clock Module installed
Bit 4 Debug Module installed
Bit 5 Rps Module installed
Bit 6 unknown value (ignore bits 0-5)
Bit 7 unsupported value (ignore bits 0-5)ro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.10 |
deviceLinkFarModulesGives a short summary of which modules are installed in the far
device. This variable is bit coded as follows:
Bit 0 G.703 Interface installed
Bit 1 Data Interface installed
Bit 2 Alarm Module installed
Bit 3 Clock Module installed
Bit 4 Debug Module installed
Bit 5 Rps Module installed
Bit 6 unknown value (ignore bits 0-5)
Bit 7 unsupported value (ignore bits 0-5)ro INTEGER .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.11 |
deviceLinkLocalHwFabDataContains the Mainboard fabrication data of the local device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.12 |
deviceLinkFarHwFabDataContains the Mainboard fabrication data of the far device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.13 |
deviceLinkLocalG703FabDataContains the G703 Module fabrication data of the local device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.14 |
deviceLinkLocalDataFabDataContains the Data Module fabrication data of the local device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.15 |
deviceLinkLocalFeatureFlagContains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed devicero OCTET STRING .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.16 |
deviceLinkFarFeatureFlagContains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed devicero OCTET STRING .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.17 |
deviceLinkFarFeatureFlagStateIndicates the state and validity of deviceLinkFarFeatureFlag.
1 Ok The values of farFeatureFlag is valid
2 TooEarly The variable was read before the LT could determine the farFeatureFlag values
3 Legacy The far device is an Ulaf-2 device and has no feature flag
254 unknown values
255 unsupported variable for addressed devicero Enumeration .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.18 |
deviceLinkSruFeatureFlagContains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed devicero OCTET STRING .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.19 |
deviceLinkNumReg3Indicates how many regenerators were detected in xDSL path 3.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported valuero Enumeration .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.20 |
deviceLinkNumReg4Indicates how many regenerators were detected in xDSL path 4.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported valuero Enumeration .1.3.6.1.4.1.1887.1.1.3.2.2.1.1.21 |
links OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.4 |
linksVers2 OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.4.2 |
link OBJECT IDENTIFIER .1.3.6.1.4.1.1887.1.1.4.2.1 |
linkConfigTable SEQUENCE OF LinkConfigEntry .1.3.6.1.4.1.1887.1.1.4.2.1.1 |
linkConfigEntry LinkConfigEntry .1.3.6.1.4.1.1887.1.1.4.2.1.1.1 |
linkConfigPortIndexThis object addresses the port number of the proxy agentro INTEGER .1.3.6.1.4.1.1887.1.1.4.2.1.1.1.1 |
linkConfigIndexThis object addresses the line card number of the OMI
equipment.ro INTEGER .1.3.6.1.4.1.1887.1.1.4.2.1.1.1.2 |
performanceThis object defines if the performance management is running
or notrw Enumeration .1.3.6.1.4.1.1887.1.1.4.2.1.1.1.4 |