The ThreeParMIB module enables SNMP-based monitoring of HP 3PAR storage array hardware and software states, exposing critical metrics such as system health, volume status, controller redundancy, disk drive conditions, and performance counters. This interface allows management platforms to retrieve real-time operational data and trap notifications for proactive fault detection and capacity planning within the storage infrastructure.

This file specifies management information interface for all HP 3PAR's products. This information is normally used by any management software that utilizes SNMP as management standard. The SNMP agent inside the device provides the specified information.
Main OID:
threepar.1.3.6.1.4.1.12925
17
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

17 total
Object Name
threeparThis file specifies management information interface for all HP 3PAR's products. This information is normally used by any management software that utilizes SNMP as management standard. The SNMP agent inside the device provides the specified information.
MODULE-IDENTITY
.1.3.6.1.4.1.12925
inservInServ product
OBJECT IDENTIFIER
.1.3.6.1.4.1.12925.1
inservAgentCapsInServ agent profile
OBJECT IDENTIFIER
.1.3.6.1.4.1.12925.1.4
inservAgentCapabilityHP 3PAR agent capability. Please note that the HP 3PAR agent supports snmpObsoleteGroup in SNMPv2-MIB instead of snmpGroup.
Unknown
.1.3.6.1.4.1.12925.1.4.1
alertTableContains critical information in notifications sent to SNMP managers. This information is translated from alerts generated by the system.
SEQUENCE OF AlertEntry
.1.3.6.1.4.1.12925.1.7
alertEntryRow Description
AlertEntry
.1.3.6.1.4.1.12925.1.7.1
indexIndex to access entries in alert table. However, the table is empty most of the time because the entry is deleted after sending the trapro
Integer32 (1)
.1.3.6.1.4.1.12925.1.7.1.1
severitySeverity of the alert. The enumeration is borrowed from Common Information Model (CIM): 0 - fatal: indicates an error occurred, but it's too late to take any actions; 1 - critical: an action is needed immediately and scope of the error is broad; 2 - major: an action is needed, the situation is serious; 3 - minor: an action is needed, but the situation is not serious; 4 - degraded/warning: the user decides whether to take an action; 5 - informational: indicates state change or status change, but it's not an error; 6 - debug: information that are logged for later analysis.ro
Enumeration
.1.3.6.1.4.1.12925.1.7.1.2
timeOccurredThe local time and date when the alert occurred. The format is 'DDD mmm dd hh:mm:ss ZZZ yyyy'. Where: DDD= day of the week (Sun, Mon, ,,,), mmm= month (Jan, Feb, Mar ...), dd= date, hh: hour, mm: minute, ss= second, ZZZ: time zone, yyyy: year.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.12925.1.7.1.3
nodeIDThe node the alert was posted on. The node number starts from 0. The maximum number of node is 32.ro
Unsigned32 ( 0 .. 31 )
.1.3.6.1.4.1.12925.1.7.1.4
componentThe component which the event applies to; for example, power supply, SCSI disk, BIOS, cage etc...ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.12925.1.7.1.5
detailsAdditional detailed description of the alert. The detail may include things like disk number, cage number the alert applies to.ro
ThreeparLongDisplayString
.1.3.6.1.4.1.12925.1.7.1.6
idUnique ID that identifies the instance of an alert. This is a unique number that is generated each time an alert is generated by the system.ro
Unsigned32 ( 1 .. 4294967295 )
.1.3.6.1.4.1.12925.1.7.1.7
messageCodeMessage code is assigned to a particular event type, and is encoded as a 32-bit number in the following way: The MSB 8 bits are reserved. The next 8 bits represent a particular subsystem or component. The LSB 16 bits are the keycode id within the subsystem. For example, Remote Copy Target Down event has a subsystem ID of 37 (remote copy subsystem), and a keycode ID of 1, thus the message code for this event = ((37 << 16) | 1) = 0x250001 = 2424833. This is shown as 'Message Code' in the CLI 'showalert' display, and also shows up in the Alerts Details Pane in the GUI.ro
Unsigned32 ( 65537 .. 4294967295 )
.1.3.6.1.4.1.12925.1.7.1.8
stateThis provides information about the state of the alert. new - new alert generated by the system acknowledged - an administrator has acknowledged the alert but may or may not have fixed it, depending on whether remedial action is necessary fixed - remedial action has been taken to fix the alert condition removed - the alert has been removed autofixed - the system has taken action to automatically resolve the alert condition.ro
Enumeration
.1.3.6.1.4.1.12925.1.7.1.9
serialNumberThe serial-number of the HP 3PAR InServ systemro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.12925.1.7.1.10
alertNotifyAlert notification contains details about an event that may affect system operations and performance. The details include all columns defined in alertTable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.12925.1.8