TRANSMODE1100
AI MIB Summary
The TRANSMODE1100 MIB provides enterprise-specific management and monitoring capabilities for Transmode optical transport hardware, exposing vendor-defined metrics for interface status, optical signal parameters, and system health. This module enables network operators to track performance data and fault conditions specific to Transmode's 1100 series transmission equipment via SNMP.
This is the enterprise specific MIB for Transmode
Main OID:
transmode.1.3.6.1.4.1.11857
376
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
376 total| Object Name |
|---|
org OBJECT IDENTIFIER .1.3 |
dod OBJECT IDENTIFIER .1.3.6 |
internet OBJECT IDENTIFIER .1.3.6.1 |
private OBJECT IDENTIFIER .1.3.6.1.4 |
enterprises OBJECT IDENTIFIER .1.3.6.1.4.1 |
transmodeThis is the enterprise specific MIB for Transmode MODULE-IDENTITY .1.3.6.1.4.1.11857 |
system1100 OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1 |
trmAlarmHandling OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1 |
trmAlarmConfig OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1.1 |
trmAlarmGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1.1.1 |
trmAutoAcknowledgeIndicates if alarms should be automatically acknowledged or not. Can be on(1) or off(2).rw Enumeration .1.3.6.1.4.1.11857.1.1.1.1.1 |
trmClearAlarmLogUsed to delete all history alarms. To delete all history alarms, a SetRequest-PDU with a clear(1) value encoding is used.rw Enumeration .1.3.6.1.4.1.11857.1.1.1.1.2 |
trmTemperatureIndicates the temperature unit used in the system. Can be celsius(1) or farenheit(2).rw Enumeration .1.3.6.1.4.1.11857.1.1.1.1.3 |
trmAlarmTemperatureHighHigh temperature level. This parameter indicates at what level a High temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenheit is used.rw INTEGER (-32767 .. 32768 ) .1.3.6.1.4.1.11857.1.1.1.1.4 |
trmAlarmTemperatureHighHystHigh termperature hysteresis. This parameter is used together with trmAlarmTempemperatureHigh to decide when a High temperature alarm will cease. The alarm will cease at trmAlarmTemperatureHigh - trmAlarmTemperatureHighHyst. See trmTemperature if deg. Celsius or Farenheit is used.rw INTEGER (-32767 .. 32768 ) .1.3.6.1.4.1.11857.1.1.1.1.5 |
trmAlarmTemperatureLowLow temperature level. This parameter indicates at what level a Low temperature alarm will occur in the system. See trmTemperature if deg. Celsius or Farenheit is used.rw INTEGER (-32767 .. 32768 ) .1.3.6.1.4.1.11857.1.1.1.1.6 |
trmAlarmTemperatureLowHystLow termperature hysteresis. This parameter is used together with trmAlarmTemperatureLow to decide when a Low temperature alarm will cease. The alarm will cease at trmAlarmTemperatureLow - trmAlarmTemperatureLowHyst. See trmTemperature if deg. Celsius or Farenheit is used.rw INTEGER (-32767 .. 32768 ) .1.3.6.1.4.1.11857.1.1.1.1.7 |
trmPluginResetUsed to reset all the plug in units. To reset all units, a SetRequest-PDU with a reset(1) value encoding is used.rw Enumeration .1.3.6.1.4.1.11857.1.1.1.1.8 |
trmOpticalInputPowerHighPINLineOptical input power high alarm level for line interface PINs. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.9 |
trmOpticalInputPowerHighAPDLineOptical input power high alarm level for client interface APDs. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.10 |
trmOpticalInputPowerLowPINLineOptical input power low alarm level for client interface PINs. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.11 |
trmOpticalInputPowerLowAPDLineOptical input power low alarm level for client interface APDs. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.12 |
trmCascadeShows if Cascading is activated or not and is also used to enable/diasable Cascading. activate(1) means activated and deactivate(2) means not activated.rw CascadeMode .1.3.6.1.4.1.11857.1.1.1.1.13 |
trmCascadeStatusDisplays the current operating mode of the Cascading. Can be deactivated[1], initializing(2), ok(3) or failure(4).ro CascadeStatus .1.3.6.1.4.1.11857.1.1.1.1.14 |
trmOpticalInputPowerHighAPDLine2Optical input power high alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.15 |
trmOpticalInputPowerLowAPDLine2Optical input power low alarm level for client interface APDs. Applicable for 76xx/15 units(repeaters). Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.16 |
trmOpticalInputPowerHigh850ClientOptical input power high alarm level for 850 nm client interface. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.17 |
trmOpticalInputPowerHigh1310ClientOptical input power high alarm level for 1310 nm client interface. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.18 |
trmOpticalInputPowerLow850ClientOptical input power low alarm level for 850 nm client interface. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.19 |
trmOpticalInputPowerLow1310ClientOptical input power low alarm level for 1310 nm client interface. Value displayed and set is dBm/10.rw INTEGER .1.3.6.1.4.1.11857.1.1.1.1.20 |
trmAlarmSeverity OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1.1.2 |
trmAlarmSeverityTableA list of all type of alarms in the system. SEQUENCE OF TrmAlarmSeverityEntry .1.3.6.1.4.1.11857.1.1.1.2.1 |
trmAlarmSeverityEntryA set of parameters that describe a alarm. TrmAlarmSeverityEntry .1.3.6.1.4.1.11857.1.1.1.2.1.1 |
trmAlarmSeverityIdAn id that uniquely identifies an alarm. INTEGER (1 .. 2147483647 ) .1.3.6.1.4.1.11857.1.1.1.2.1.1.1 |
trmAlarmSeverityNameThe alarm name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.1.2.1.1.2 |
trmAlarmSeverityLevelIndicates the alarm severity. Can be set to critical (1) , major (2) , minor (3) , warning (4) or off(5)rw AlarmSeverity .1.3.6.1.4.1.11857.1.1.1.2.1.1.3 |
trmAlarmExternal OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1.1.3 |
trmAlarmExternalTableA list of all external alarms. SEQUENCE OF TrmAlarmExternalEntry .1.3.6.1.4.1.11857.1.1.1.3.1 |
trmAlarmExternalEntryA set of parameters that describe a external alarm. TrmAlarmExternalEntry .1.3.6.1.4.1.11857.1.1.1.3.1.1 |
trmAlarmExternalIdAn id that uniquely identifies an external alarm. 1 = External alarm 1, 2 = External alarm 2 and 3 = External alarm 3. INTEGER (1 .. 2147483647 ) .1.3.6.1.4.1.11857.1.1.1.3.1.1.1 |
trmAlarmExternalNameThe External alarm name. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.1.3.1.1.2 |
trmAlarmExternalLevelAlarm level that activates the alarm. Can be activelow (1) or activehigh (2).rw ExternalAlarmLevel .1.3.6.1.4.1.11857.1.1.1.3.1.1.3 |
trmAlarmLog OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1.2 |
trmAlarmLogTableA table of history alarms in the system. The number of entries are as many as there are acknowledged alarms in the system. SEQUENCE OF TrmAlarmLogEntry .1.3.6.1.4.1.11857.1.1.2.1 |
trmAlarmLogEntryA set of parameters that describe a history alarm. A row in this table can not be created or deleted by SNMP operations on columns of the table. TrmAlarmLogEntry .1.3.6.1.4.1.11857.1.1.2.1.1 |
trmAlarmLogIndexThe index for this alarm entry. INTEGER (1 .. 2147483647 ) .1.3.6.1.4.1.11857.1.1.2.1.1.1 |
trmAlarmLogRackNumberThe rack number where the alarm occured.ro RackNumber .1.3.6.1.4.1.11857.1.1.2.1.1.2 |
trmAlarmLogSlotNumberThe slot number where the alarm occured.ro SlotNumber .1.3.6.1.4.1.11857.1.1.2.1.1.3 |
trmAlarmLogNameThe alarm description.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.2.1.1.4 |
trmAlarmLogSeverityThe alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4).ro PerceivedSeverity .1.3.6.1.4.1.11857.1.1.2.1.1.5 |
trmAlarmLogUnitThe type, version and index for the unit associated with the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.2.1.1.6 |
trmAlarmLogSerialNumberThe serial number for the unit associated with the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.2.1.1.7 |
trmAlarmLogActTimeThe time the alarm was generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.2.1.1.8 |
trmAlarmLogDeactTimeThe time the alarm was deactivated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.2.1.1.9 |
trmAlarmLogAckTimeThis time the alarm was acknowledged.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.2.1.1.10 |
trmAlarmLogAckUserThe user that acknowledged the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.2.1.1.11 |
trmAlarmActive OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1.3 |
trmAlarmActiveGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.1.3.1 |
trmAlarmActiveCounterIndicates the total number of active alarms in the system.ro INTEGER (-1 .. 32768 ) .1.3.6.1.4.1.11857.1.1.3.1.1 |
trmAlarmActiveAcknowledgeAllDeactAcknowledges all alarm that is not acknowledged and is deactivated. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used.rw AlarmAcknowledge .1.3.6.1.4.1.11857.1.1.3.1.2 |
trmAlarmActiveAcknowledgeAllAcknowledgedges all alarms that is not acknowledged. To acknowledge, a SetRequest-PDU with a yes(1) value encoding is used.rw AlarmAcknowledge .1.3.6.1.4.1.11857.1.1.3.1.3 |
trmAlarmActiveTableA table of active alarms in the system. With active alarm the meaning is a not acknowledged alarm. The number of entries are as many as there are not acknowledged alarms in the system. SEQUENCE OF TrmAlarmActiveEntry .1.3.6.1.4.1.11857.1.1.3.2 |
trmAlarmActiveEntryAn entry in the table of active alarms in the system. A row in this table can not be created or deleted by SNMP operations on columns of the table. TrmAlarmActiveEntry .1.3.6.1.4.1.11857.1.1.3.2.1 |
trmAlarmActiveIndexThe index for this alarm entry. INTEGER (1 .. 2147483647 ) .1.3.6.1.4.1.11857.1.1.3.2.1.1 |
trmAlarmActiveRackNumberThe rack number where the alarm occured.ro RackNumber .1.3.6.1.4.1.11857.1.1.3.2.1.2 |
trmAlarmActiveSlotNumberThe slot number where the alarm occured.ro SlotNumber .1.3.6.1.4.1.11857.1.1.3.2.1.3 |
trmAlarmActiveNameThe alarm descriptionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.3.2.1.4 |
trmAlarmActiveSeverityThe alarm severity. Can be indeterminate (0) , critical (1) , major (2) , minor (3) or warning (4).ro PerceivedSeverity .1.3.6.1.4.1.11857.1.1.3.2.1.5 |
trmAlarmActiveUnitThe type, version and index of the unit associated with the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.3.2.1.6 |
trmAlarmActiveSerialNumberThe serial number of the unit associated with the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.3.2.1.7 |
trmAlarmActiveActTimeThe time the alarm was generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.3.2.1.8 |
trmAlarmActiveDeactTimeThe time the alarm was deactivated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.1.3.2.1.9 |
trmAlarmActiveAcknowledgeThis oid is used to acknowledge a alarm. To acknowledge a alarm, a SetRequest-PDU with a acknowledge(1) value encoding is used.rw AlarmAcknowledge .1.3.6.1.4.1.11857.1.1.3.2.1.10 |
trmSubrack OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2 |
trmSubrackList OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.1 |
trmSubrackListTableA list of units present in the subrack(s). SEQUENCE OF TrmSubrackListEntry .1.3.6.1.4.1.11857.1.2.1.1 |
trmSubrackListEntryA set of parameters that describe a unit. TrmSubrackListEntry .1.3.6.1.4.1.11857.1.2.1.1.1 |
trmListRackNumberThis object indicates in what rack the unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.1.1.1.1 |
trmListSlotNumberThis object indicates in what slot the unit is situated in. Can be slot 1-12. SlotNumber .1.3.6.1.4.1.11857.1.2.1.1.1.2 |
trmListUnitPresentThis object indicates if the unit is present yes(1) or not no(2).ro Present .1.3.6.1.4.1.11857.1.2.1.1.1.3 |
trmListProductNumberThe Product number of the unit (XXYY/ZZ) where: Board type = XX Board version = YY Board index = ZZ.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.1.1.1.4 |
trmListProductDescriptionA product description of the unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.1.1.1.5 |
trmListHwRevisionThe hardware revision of the unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.1.1.1.6 |
trmListSerialNumberThe serial number of the unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.1.1.1.7 |
trmListManufacturingDateThe manufacturing date of the unit. Format is Year:Week.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.1.1.1.8 |
trmListSoftwareProdNoThe software product number of the software on this unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.1.1.1.9 |
trmListSwVersionRevision number of the software on this unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.1.1.1.10 |
trmSubrackUnits OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2 |
trm6001 OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.1 |
trm6001PM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.1.1 |
trm6001TableList of NMB(s). SEQUENCE OF Trm6001Entry .1.3.6.1.4.1.11857.1.2.2.1.1.1 |
trm6001EntryA set of parameters that describes an NMB Trm6001Entry .1.3.6.1.4.1.11857.1.2.2.1.1.1.1 |
trm6001RackNumberThe network management board rack number. RackNumber .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.1 |
trm6001SlotNumberThe network management board slot number. SlotNumberNmb .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.2 |
trm6001IPAddressThe network management board IP address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.3 |
trm6001MACAddressThe network management board MAC address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.4 |
trm6001TemperatureThe network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used.ro INTEGER (1 .. 2147483647 ) .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.5 |
trm6001UpTimeThe network management board up time.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.6 |
trm6001DateUsed to set the NMB date on format YYYY-MM-DD.rw TrmDate .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.7 |
trm6001TimeUsed to set the NMB time on format HH:MM:SS.rw TrmTime .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.8 |
trm6001SwResetUsed to reset the NMB unit. To reset the NMB unit, a SetRequest-PDU with a reset(1) value encoding is used.rw Enumeration .1.3.6.1.4.1.11857.1.2.2.1.1.1.1.9 |
trm6001FM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.1.2 |
trm6001Traps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.1.2.0 |
trm6001TrapExternal1This trap is sent when a External 1 alarm is generated at the NMB 6001 unit. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.1.2.0.1 |
trm6001TrapExternal2This trap is sent when a External 2 alarm is generated at the NMB 6001 unit. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.1.2.0.2 |
trm6001TrapExternal3This trap is sent when a External 3 alarm is generated at the NMB 6001 unit. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.1.2.0.3 |
trm6001CascadeFailureThis trap is sent when a attempt to enable Cascading has failed or connection is lost with the cascading rack. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.1.2.0.4 |
trm9xxx OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.2 |
trm9xxxPM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.2.1 |
trm9xxxTableA list of power supply units in the subrack(s). SEQUENCE OF Trm9xxxEntry .1.3.6.1.4.1.11857.1.2.2.2.1.1 |
trm9xxxEntryA set of parameters that describe a power supply unit. Trm9xxxEntry .1.3.6.1.4.1.11857.1.2.2.2.1.1.1 |
trm9xxxRackNumberThis object indicates in what rack the power supply is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.2.1.1.1.1 |
trm9xxxSlotNumberThis object indicates in what slot number the power supply is situated in. Can be slot 10 or 11. SlotNumberPS .1.3.6.1.4.1.11857.1.2.2.2.1.1.1.2 |
trm9xxxPresentThis parameter indicates if the power supply is present or not. yes(1) means present and no(2) means not present.ro Present .1.3.6.1.4.1.11857.1.2.2.2.1.1.1.3 |
trm9xxxTypeThis parameter describes what kind of power supply this unit is. Power9048(2) means a power supply with input pover 48 VDC, Power9220(3) means 100-240 VAC. If the type is unknown this parameter is unknown(1).ro PowerType .1.3.6.1.4.1.11857.1.2.2.2.1.1.1.4 |
trm9xxxStatusThis parameter indicates the status of the power supply. off(1) means that the power supply not is operating and on(2) means that it is operating.ro PowerStatus .1.3.6.1.4.1.11857.1.2.2.2.1.1.1.5 |
trm9xxxFM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.2.2 |
trm9xxxTraps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.2.2.0 |
trm9xxxTrapFailureThis trap indicates that a fault was detected on a power supply or the input power is removed. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.2.2.0.1 |
trm9xxxTrapMissingThis trap is sent when a power supply is missing. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.2.2.0.2 |
trm75xx OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.3 |
trm75xxPM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.3.1 |
trm75xxTableA list of 70 & 75 units in the subrack(s). SEQUENCE OF Trm75xxEntry .1.3.6.1.4.1.11857.1.2.2.3.1.1 |
trm75xxEntryA set of parameters that describe a 70 or a 75 unit. Trm75xxEntry .1.3.6.1.4.1.11857.1.2.2.3.1.1.1 |
trm75xxRackNumberThis parameter indicates in what rack the unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.1 |
trm75xxSlotNumberThis parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8. BoardNumber .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.2 |
trm75xxRxLineThis parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.3 |
trm75xxEstProtLineThis parameter indicates the Estimated Protocol for the line interface input.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.4 |
trm75xxEstFibRateLineThis parameter indicates the Estimated Fiber Rate for the line interface input in Mbit/s.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.5 |
trm75xxTxLineThis parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.6 |
trm75xxTxModeThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF.rw TxMode75 .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.7 |
trm75xxWavelengthLineThis parameter indicates the nominal wavelength for the line interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.8 |
trm75xxRxClientThis parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.9 |
trm75xxEstProtClientThis parameter indicates the Estimated Protocol for the client interface input.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.10 |
trm75xxEstFibRateClientThis parameter indicates the Estimated Fiber Rate for the client interface input in Mbit/s.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.11 |
trm75xxTxClientThis parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.12 |
trm75xxTxModeClientThis object is obsolete and not used anymore.roobsolete TxMode75 .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.13 |
trm75xxIDStringClientThis parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.14 |
trm75xxIPAddressClientThis parameter indentifies the equipment(IP Address) connected to the client interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.15 |
trm75xxWavelengthClientThis parameter indicates the nominal wavelength for the client interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.16 |
trm75xxSpeedLimitThis parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm75xxTxMode is disabled(2). Speed Limit can be set in 3 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12.rw SpeedLimit75 .1.3.6.1.4.1.11857.1.2.2.3.1.1.1.17 |
trm75xxFM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.3.2 |
trm75xxTraps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.3.2.0 |
trm75xxTrapGlitchLineThis trap is sent when a unit experiences a split second optical input power glitch at the line interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.1 |
trm75xxTrapLopLineThis trap is sent when the optical input power is lost at the line interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.2 |
trm75xxTrapTxLineThis trap is sent when a unit fails to generate optical output power at Tx line interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.3 |
trm75xxTrapTxDisableLineThis trap is sent when the optical output power for the line interface is disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.4 |
trm75xxTrapGlitchClientThis trap is sent when a unit experiences a split second optical input power glitch at the client interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.5 |
trm75xxTrapLopClientThis trap is sent when the optical input power is lost at the client interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.6 |
trm75xxTrapTxClientThis trap is sent when a unit fails to generate optical output power at Tx client. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.7 |
trm75xxTrapTxDisableClientThis trap is sent when the optical output power for the client interface is disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.3.2.0.8 |
trm76xx OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.4 |
trm76xxPM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.4.1 |
trm76xxTableA list of 76YY/ZZ in the subrack(s). SEQUENCE OF Trm76xxEntry .1.3.6.1.4.1.11857.1.2.2.4.1.1 |
trm76xxEntryA set of parameters that describe the Subrack units Trm76xxEntry .1.3.6.1.4.1.11857.1.2.2.4.1.1.1 |
trm76xxRackNumberThis parameter indicates in what rack the unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.1 |
trm76xxSlotNumberThis parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. BoardNumber .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.2 |
trm76xxTemperatureThis parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.3 |
trm76xxCDRThis parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11) or gigabitEthernetx2(12). custom(3) can not be set, it just indicates if a custom protocol is set with oid trm76xxCustomFibRate.rw CDRMode .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.4 |
trm76xxCustomFibRateThis parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s.rw INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.5 |
trm76xxTxModeThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)rw TxMode76 .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.6 |
trm76xxLineLoopModeThis parameter is used to set the line loop mode. Can be set to normal(1) or looptest(2). normal(1): The line loop test function is off. looptest(2): Line is looped, RX=TX. (Normally, Loop test is only used for installation, test purpose or fault-location).rw LineLoopMode .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.7 |
trm76xxSwResetUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.rw Enumeration .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.8 |
trm76xxRxLineThis parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.9 |
trm76xxOpticalInPowLineThis parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.10 |
trm76xxSpeedLimitThis parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm76xxTxMode is disabled(2) or forcedon(3). Speed Limit can be set in 4 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. highLimit(4): All protocols above + Fibre channel & Gigabit Ethernet.rw SpeedLimit76 .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.11 |
trm76xxEstProtLineThis parameter indicates the Estimated Protocol for the line interface Rx.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.12 |
trm76xxEstFibRateLineThis parameter indicates the Estimated Fiber Rate for the line interface Rx in Mbit/s.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.13 |
trm76xxTxLineThis parameter indicates the status of the optical output power for the line interface. It corresponds to the line Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.14 |
trm76xxOpticalOutPowLineThis parameter indicates the optical output power for the line interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.15 |
trm76xxProdOutPowLineThis parameter indicates the production output power for the line interface. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 to show the production output power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.16 |
trm76xxLaserBiasCurLineThis parameter indicates the laser bias current for the line interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.17 |
trm76xxProdLaserBiasCurLineThis parameter indicates the production laser bias current for the line interface. Divide this value by 10 to show the laser bias current in mA.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.18 |
trm76xxWavelengthLineThis parameter indicates the nominal wavelength for the line interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.19 |
trm76xxRxClientThis parameter indicates the status of the optical input for the client interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.20 |
trm76xxEstProtClientThis parameter indicates the Estimated Protocol for the client interface Rx.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.21 |
trm76xxEstFibRateClientThis parameter indicates the Estimated Fiber Rate for the client interface Rx in Mbit/s.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.22 |
trm76xxTxClientThis parameter indicates the status of the optical output power for the client interface. It corresponds to the client Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.23 |
trm76xxIDStringClientThis parameter identifies the equipment(ID String) connected to the client interface. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.24 |
trm76xxIPAddressClientThis parameter indentifies the equipment(IP Address) connected to the client interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.25 |
trm76xxWavelengthClientThis parameter indicates the nominal wavelength for the client interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.26 |
trm76xxOpticalInPowClientThis parameter indicates the Optical input power for the client interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.27 |
trm76xxOpticalOutPowClientThis parameter indicates the optical output power for the client interface. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.28 |
trm76xxLaserBiasCurClientThis parameter indicates the laser bias current for the client interface. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.4.1.1.1.29 |
trm76xxFM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.4.2 |
trm76xxTraps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.4.2.0 |
trm76xxTrapCDRAutoModeRangeChangeLineThis trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used consider goto manual mode instead. This trap concerns the regeneration at the Tx line output. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.1 |
trm76xxTrapRxGlitchLineThis trap is sent when a unit experiences a split second optical input power glitch at the line interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.2 |
trm76xxTrapLopLineThis trap is sent when the optical input power is lost at the line interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.3 |
trm76xxTrapRxHighPowerLineThis trap is sent when the optical input power for line is higher than trmOpticalInputPowerHighPINLine or trmOpticalInputPowerHighAPDLine. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.4 |
trm76xxTrapRxLowPowerLineThis trap is sent when the optical input power for line is lower than trmOpticalInputPowerLowPINLine or trmOpticalInputPowerLowAPDLine. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.5 |
trm76xxTrapLoLLineThis trap is sent when the line Tx indicates loss of 3R synchronization. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.6 |
trm76xxTrapTxLineThis trap is sent when a unit fails to generate optical output power at Tx line. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.7 |
trm76xxTrapSFPFailureLineThis trap/alarm is not used in the system and is obsolete.obsolete NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.8 |
trm76xxTrapSFPMissingLineThis trap/alarm is not used in the system and is obsolete.obsolete NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.9 |
trm76xxTrapCDRAutoModeRangeChangeClientThis trap is sent when a client equipment might be using a protocol not specified for auto mode or it might have changed the protocol. If auto mode is used consider goto manual mode instead. This trap concerns the regeneration at the Tx client output. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.10 |
trm76xxTrapRxGlitchClientThis trap is sent when a unit experiences a split second optical input power glitch at the client interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.11 |
trm76xxTrapLopClientThis trap is sent when the optical input power is lost at the client interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.12 |
trm76xxTrapRxHighPowerClientThis trap/alarm is not used in the system and the object is obsolete.obsolete NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.13 |
trm76xxTrapRxLowPowerClientThis trap/alarm is not used in the system and the object is obsolete.obsolete NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.14 |
trm76xxTrapLoLClientThis trap is sent when the client Tx indicates loss of 3R synchronization. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.15 |
trm76xxTrapTxClientThis trap is sent when a unit fails to generate optical output power at Tx client. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.16 |
trm76xxTrapSFPFailureClientThis trap is sent when a unit have a client SFP transiever got a failure or a Bias temperature alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.17 |
trm76xxTrapSFPMissingClientThis trap is sent when a unit doesn't have a client SFP transiever. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.18 |
trm76xxTrapTxDisableThis trap is sent when the optical output power for both the line and client interface have been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.19 |
trm76xxTrapLaserDegradationLineThis trap is sent when there is a laser degradation on the line laser. This means that the laser bias current is raised to be able to keep the optical output from the laser. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.20 |
trm76xxTrapEyeQualityLineFor future use. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.21 |
trm76xxTrapEyeQualityClientFor future use. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.4.2.0.22 |
trm803x OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.5 |
trm803xPM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.5.1 |
trm803xTableA list of 803x units. SEQUENCE OF Trm803xEntry .1.3.6.1.4.1.11857.1.2.2.5.1.1 |
trm803xEntryA set of parameters that describe a 803x unit. Trm803xEntry .1.3.6.1.4.1.11857.1.2.2.5.1.1.1 |
trm803xRackNumberThis object indicates in what rack the 803x unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.5.1.1.1.1 |
trm803xSlotNumberThis object indicates in what slot number the 803x unitis situated in. Can only be slot 12. INTEGER .1.3.6.1.4.1.11857.1.2.2.5.1.1.1.2 |
trm803xMuxTypeThis parameter indicates what Mux type this is. Can be none(1), mux8030(2), mux8031(3), mux8032(4), mux8033(5) or mux8034(6).ro MuxType .1.3.6.1.4.1.11857.1.2.2.5.1.1.1.3 |
trm803xIDStringLineThis parameter identifies the equipment connected to the line interface. The ID string can be used to indentify a fiber pair/link. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.5.1.1.1.4 |
trm803xIPAddressLineThis parameter identifies the equipment connected to the line interface. The IP address can be used to indentify the corresponding NMB unit.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.5.1.1.1.5 |
trm2204 OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.6 |
trm2204PM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.6.1 |
trm2204TableA list of 2204 units. SEQUENCE OF Trm2204Entry .1.3.6.1.4.1.11857.1.2.2.6.1.1 |
trm2204EntryA set of parameters that describe a 2204 unit. Trm2204Entry .1.3.6.1.4.1.11857.1.2.2.6.1.1.1 |
trm2204RackNumberThis object indicates in what rack the 2204 unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.6.1.1.1.1 |
trm2204SlotNumberThis object indicates in what slot number the 2204 unitis situated in. Can be slot 1-8. INTEGER .1.3.6.1.4.1.11857.1.2.2.6.1.1.1.2 |
trm2204SecurityModeThis parameter indicates the security mode for the unit. It is also used to set the Security Mode for the unit. Can be activated(1) or deactivated(2).rw SecurityMode .1.3.6.1.4.1.11857.1.2.2.6.1.1.1.3 |
trm26xx OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.7 |
trm26xxPM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.7.1 |
trm26xxTableA list of 26xx units in the subrack(s). SEQUENCE OF Trm26xxEntry .1.3.6.1.4.1.11857.1.2.2.7.1.1 |
trm26xxEntryA set of parameters that describe a 26xx unit. Trm26xxEntry .1.3.6.1.4.1.11857.1.2.2.7.1.1.1 |
trm26xxRackNumberThis parameter indicates in what rack the unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.1 |
trm26xxSlotNumberThis parameter indicates in what slot number the unit is situated in. Can be slot 1 - 8. BoardNumber .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.2 |
trm26xxStatusThis parameter indicates the status of the optical input for the line interface. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.3 |
trm26xxTemperatureThe network management board temperature in deg. C or deg. F. See trmTemperature if deg. Celsius or Farenheit is used.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.4 |
trm26xxTxModeThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF.rw TxMode75 .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.5 |
trm26xxSwResetUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.rw Enumeration .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.6 |
trm26xxOpticalPowerPIN1ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.7 |
trm26xxOpticalPowerPIN2ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.8 |
trm26xxLogOpticalPowerro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.9 |
trm26xxTemperatureTEC1ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.10 |
trm26xxTemperatureTEC2ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.11 |
trm26xxVoltageTEC1ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.12 |
trm26xxVoltageTEC2roobsolete INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.13 |
trm26xxCurrentTEC1ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.14 |
trm26xxCurrentTEC2ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.15 |
trm26xxCurrentBIAS1ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.16 |
trm26xxCurrentBIAS2ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.17 |
trm26xxVoltageBIAS1ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.18 |
trm26xxVoltageBIAS2ro INTEGER .1.3.6.1.4.1.11857.1.2.2.7.1.1.1.19 |
trm26xxFM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.7.2 |
trm26xxTraps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.7.2.0 |
trm26xxTrapTEC1Faulty NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.7.2.0.1 |
trm26xxTrapTEC2Faulty NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.7.2.0.2 |
trm26xxTrapBIAS1Faulty NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.7.2.0.3 |
trm26xxTrapBIAS2Faulty NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.7.2.0.4 |
trm26xxTrapPIUTempShutdown NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.7.2.0.5 |
trm26xxTrapOpticalLinkdown NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.7.2.0.6 |
trm26xxTrapTxDisableThis trap is sent when the amplifier has been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.7.2.0.7 |
trm25xx OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.8 |
trm25xxPM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.8.1 |
trm25xxTableA list of 25xx in the subrack(s). SEQUENCE OF Trm25xxEntry .1.3.6.1.4.1.11857.1.2.2.8.1.1 |
trm25xxEntryA set of parameters that describe the Subrack units Trm25xxEntry .1.3.6.1.4.1.11857.1.2.2.8.1.1.1 |
trm25xxRackNumberThis parameter indicates in what rack the unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.1 |
trm25xxSlotNumberThis parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. BoardNumber .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.2 |
trm25xxWorkingLineStatusThis parameter indicates the Working Line status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.3 |
trm25xxProtectingLineStatusThis parameter indicates the Protecting Line status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.4 |
trm25xxTemperatureThis parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.5 |
trm25xxSwResetUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.rw Enumeration .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.6 |
trm25xxRxLineThis parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.7 |
trm25xxOpticalInPowLineThis parameter indicates the Optical input power for the line Subrack. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.8 |
trm25xxSpeedLimitThis parameter indicates the speed limit set for this unit and is used to set a new speed limit. It generates an alarm and disables Line and Client Tx if the Client bitrate is higher than a predefined protocol. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if trm25xxTxMode is disabled(2) or forcedon(3). Speed Limit can be set in 4 modes to allow different protocols: noLimit(1): Any protocol is allowed. lowLimit(2): 100Base-FX, STM1/OC3, ESCON & Video 270Mb. mediumLimit(3): All protocols above + STM4/OC-12. highLimit(4): All protocols above + Fibre channel & Gigabit Ethernet.rw SpeedLimit76 .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.9 |
trm25xxEstProtLineThis parameter indicates the Estimated Protocol for the line Subrack input.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.10 |
trm25xxEstFibRateLineThis parameter indicates the Estimated Fiber Rate for the line Subrack input in Mbit/s.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.11 |
trm25xxTxLineThis parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.12 |
trm25xxOpticalOutPowLineThis parameter indicates the optical output power for the line Subrack. If data not is available yet this parameter is -1(-0.1 dBm). If this parameter is -100 (-10 dBm) the output power is equal too or less than -100 (-10 dBm). Divide this value by 10 to show the optical output power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.13 |
trm25xxProdOutPowLineThis parameter indicates the production output power for the line Subrack. If data not is valid yet this parameter is -1 (-0.1 dBm). Divide this value by 10 to show the production output power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.14 |
trm25xxLaserBiasCurLineThis parameter indicates the laser bias current for the line Subrack. If this parameter is 5450(545 mA) the laser bias current is more or equal to 545 mA. Divide this value by 10 to show the laser bias current in mA.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.15 |
trm25xxProdLaserBiasCurLineThis parameter indicates the production laser bias current for the line Subrack. Divide this value by 10 to show the laser bias current in mA.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.16 |
trm25xxCDRThis parameter indicates the working mode of the CDR clock recovery circuit. Can be auto3R(1), bypass2R(2), custom(3),fddiOR100Base-FX(4), stm1orOC-3(5), video270Mbps(6), stm4orOC-12(7), gigabitEthernet(8), fibreChannel(9), fibreChannelx2(10), stm16orOC-48(11) or gigabitEthernetx2(12). custom(3) can not be set, it just indicates if a custom protocol is set with oid trm25xxCustomFibRate.rw CDRMode .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.17 |
trm25xxCustomFibRateThis parameter is used to set the working mode of the CDR clock recovery circuit(Custom mode). Custom mode can be set between 30000 and 2700000 Kbit/s.rw INTEGER .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.18 |
trm25xxTxModeThis parameter indicates the mode of the optical transmitter for line and client TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)rw TxMode76 .1.3.6.1.4.1.11857.1.2.2.8.1.1.1.19 |
trm25xxFM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.8.2 |
trm25xxTraps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.8.2.0 |
trm25xxTrapWorkingLineFailureThis trap is sent when the Working Line goes down. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.8.2.0.1 |
trm25xxTrapProtectingLineFailureThis trap is sent when the Protecting Line goes down. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.8.2.0.2 |
trm25xxTrapWorkingAndProtectingLineFailureThis trap is sent when both the Working and Protecting Line goes down. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.8.2.0.3 |
trm53005500 OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.9 |
trm53005500PM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.9.1 |
trm53005500TableA list of all 5300/01 and 5500/01 units in the subrack(s). SEQUENCE OF Trm53005500Entry .1.3.6.1.4.1.11857.1.2.2.9.1.1 |
trm53005500EntryA set of parameters that describe a 5300/01 or 5500/01 unit. Trm53005500Entry .1.3.6.1.4.1.11857.1.2.2.9.1.1.1 |
trm53005500RackNumberThis parameter indicates in what rack the unit is situated in. RackNumber .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.1 |
trm53005500SlotNumberThis parameter indicates in what slot number the unit is situated in. Can be any of slot 1 - 8. BoardNumber .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.2 |
trm53005500TemperatureThis parameter indicates the temperature measured by the unit in deg. C or deg. F. See trmSubrackConfigTemp if deg. Celsius or Farenheit is used.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.3 |
trm53005500SwResetUsed to reset the unit. To reset the unit, a SetRequest-PDU with a reset(1) value encoding is used.rw Enumeration .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.4 |
trm53005500WavelengthLineThis parameter indicates the nominal wavelength for the line interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.5 |
trm53005500RxLineThis parameter indicates the status of the optical input for the line Subrack. It corresponds to the client Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.6 |
trm53005500OpticalInPowLineThis parameter indicates the Optical input power for the line interface. When the Optical input power is to low to measure this parameter is -500 (-50 dBm). If the Optical output power is to high to measure this parameter is -20 (-2 dBm). If this parameter is invalid -1 (-0.1 dBm) is returned. Divide this value by 10 to show optical input power in dBm.ro INTEGER .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.7 |
trm53005500TxLineThis parameter indicates the status of the optical output power for the line Subrack. It corresponds to the line Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.8 |
trm53005500TxModeLineThis parameter indicates the mode of the optical transmitter for line TX. Can be set to normal(1) or disabled(2). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF.rw TxMode75 .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.9 |
trm53005500WavelengthClient1This parameter indicates the nominal wavelength for the client 1 interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.10 |
trm53005500RxClient1This parameter indicates the status of the optical input for the client 1 interface. It corresponds to the client 1 Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.11 |
trm53005500CDRClient1This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4).rw CDR55Mode .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.12 |
trm53005500TxClient1This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.13 |
trm53005500TxModeClient1This parameter indicates the mode of the optical transmitter for client 1 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)rw TxMode76 .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.14 |
trm53005500IDStringClient1This parameter identifies the equipment(ID String) connected to the client 1 interface. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.15 |
trm53005500IPAddressClient1This parameter indentifies the equipment(IP Address) connected to the client 1 interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.16 |
trm53005500WavelengthClient2This parameter indicates the nominal wavelength for the client 2 interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.17 |
trm53005500RxClient2This parameter indicates the status of the optical input for the client 2 interface. It corresponds to the client 2 Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.18 |
trm53005500CDRClient2This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4).rw CDR55Mode .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.19 |
trm53005500TxClient2This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.20 |
trm53005500TxModeClient2This parameter indicates the mode of the optical transmitter for client 2 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)rw TxMode76 .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.21 |
trm53005500IDStringClient2This parameter identifies the equipment(ID String) connected to the client 2 interface. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.22 |
trm53005500IPAddressClient2This parameter indentifies the equipment(IP Address) connected to the client 2 interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.23 |
trm53005500WavelengthClient3This parameter indicates the nominal wavelength for the client 3 interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.24 |
trm53005500RxClient3This parameter indicates the status of the optical input for the client 3 interface. It corresponds to the client 3 Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.25 |
trm53005500CDRClient3This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4).rw CDR55Mode .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.26 |
trm53005500TxClient3This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.27 |
trm53005500TxModeClient3This parameter indicates the mode of the optical transmitter for client 3 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)rw TxMode76 .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.28 |
trm53005500IDStringClient3This parameter identifies the equipment(ID String) connected to the client 3 interface. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.29 |
trm53005500IPAddressClient3This parameter indentifies the equipment(IP Address) connected to the client 3 interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.30 |
trm53005500WavelengthClient4This parameter indicates the nominal wavelength for the client 4 interface transiever.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.31 |
trm53005500RxClient4This parameter indicates the status of the optical input for the client 4 interface. It corresponds to the client 4 Rx LED status of the unit. Can be Receiving or Not receiving.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.32 |
trm53005500CDRClient4This parameter indicates the working mode of the CDR clock recovery circuit and is used to change working mode. Only setable for unit 5500/01. Can be ESCON(1), stm1orOC-3(2), fddiOR100Base-FX(3), or syncClock16MHz(4).rw CDR55Mode .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.33 |
trm53005500TxClient4This parameter indicates the status of the optical output power. It corresponds to the Tx LED status of the unit. Can be on or off.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.34 |
trm53005500TxModeClient4This parameter indicates the mode of the optical transmitter for client 4 TX. Can be set to normal(1), disabled(2) or forcedon(3). normal (1): Optical output when receiving signal. disabled(2): Optical output is OFF. forcedon(3): Optical output is ON. (Normally, forcedon(3) is used for test purpose only)rw TxMode76 .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.35 |
trm53005500IDStringClient4This parameter identifies the equipment(ID String) connected to the client 4 interface. Maximum number of characters is 20.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.36 |
trm53005500IPAddressClient4This parameter indentifies the equipment(IP Address) connected to the client 4 interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11857.1.2.2.9.1.1.1.37 |
trm53005500FM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.9.2 |
trm53005500Traps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.2.9.2.0 |
trm53005500TrapRxLinkdownLineThis trap is sent when the Line Rx signal is out of sync or has been lost. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.1 |
trm53005500TrapExternalsyncFailureLineThis trap is sent when the Line external sync signal is lost or is out of sync. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.2 |
trm53005500TrapSfpMissingLineThis trap is sent when the Line SFP transiever not is mounted. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.3 |
trm53005500TrapSfpBadTypeLineThis trap is sent when a invalid Line SFP is used. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.4 |
trm53005500TrapSfpFaultyLineThis trap is sent when the Line SFP is faulty. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.5 |
trm53005500TrapRxGlitchLineThis trap is sent when a unit experiences a split second optical input power glitch at the Line interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.6 |
trm53005500TrapTxGlitchLineThis trap is sent when a unit experiences a split second optical transmission glitch at the Line interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.7 |
trm53005500TrapTxDisabledLineThis trap is sent when the optical output power for the line interface have been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.8 |
trm53005500TrapRxLinkDownClient1This trap is sent when the Client 1 Rx signal is out of sync or has been lost. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.9 |
trm53005500TrapTxOutOfSyncClient1This trap is sent when the Client 1 tx output signal is outside the selected frequencey range. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.10 |
trm53005500TrapSfpMissingClient1This trap is sent when the Client 1 SFP transiever not is mounted. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.11 |
trm53005500TrapSfpBadTypeClient1This trap is sent when a unsupported Client 1 SFP is used. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.12 |
trm53005500TrapSfpFaultyClient1This trap is sent when the Client 1 SFP is faulty. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.13 |
trm53005500TrapTxGlitchClient1This trap is sent when a unit experiences a split second optical transmission glitch at the Client 1 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.14 |
trm53005500TrapRxGlitchClient1This trap is sent when a unit experiences a split second optical input power glitch at the Client 1 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.15 |
trm53005500TrapTxDisabledClient1This trap is sent when the optical output power for the client 1 interface have been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.16 |
trm53005500TrapRxLinkDownClient2This trap is sent when the Client 2 Rx signal is out of sync or has been lost. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.17 |
trm53005500TrapTxOutOfSyncClient2This trap is sent when the Client 2 tx output signal is outside the selected frequencey range. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.18 |
trm53005500TrapSfpMissingClient2This trap is sent when the Client 2 SFP transiever not is mounted. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.19 |
trm53005500TrapSfpBadTypeClient2This trap is sent when a unsupported Client 2 SFP is used. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.20 |
trm53005500TrapSfpFaultyClient2This trap is sent when the Client 2 SFP is faulty. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.21 |
trm53005500TrapTxGlitchClient2This trap is sent when a unit experiences a split second optical transmission glitch at the Client 2 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.22 |
trm53005500TrapRxGlitchClient2This trap is sent when a unit experiences a split second optical input power glitch at the Client 2 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.23 |
trm53005500TrapTxDisabledClient2This trap is sent when the optical output power for the client 2 interface have been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.24 |
trm53005500TrapRxLinkDownClient3This trap is sent when the Client 3 Rx signal is out of sync or has been lost. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.25 |
trm53005500TrapTxOutOfSyncClient3This trap is sent when the Client 3 tx output signal is outside the selected frequencey range. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.26 |
trm53005500TrapSfpMissingClient3This trap is sent when the Client 3 SFP transiever not is mounted. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.27 |
trm53005500TrapSfpBadTypeClient3This trap is sent when a unsupported Client 3 SFP is used. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.28 |
trm53005500TrapSfpFaultyClient3This trap is sent when the Client 3 SFP is faulty. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.29 |
trm53005500TrapTxGlitchClient3This trap is sent when a unit experiences a split second optical transmission glitch at the Client 3 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.30 |
trm53005500TrapRxGlitchClient3This trap is sent when a unit experiences a split second optical input power glitch at the Client 3 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.31 |
trm53005500TrapTxDisabledClient3This trap is sent when the optical output power for the client 3 interface have been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.32 |
trm53005500TrapRxLinkDownClient4This trap is sent when the Client 4 Rx signal is out of sync or has been lost. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.33 |
trm53005500TrapTxOutOfSyncClient4This trap is sent when the Client 4 tx output signal is outside the selected frequencey range. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.34 |
trm53005500TrapSfpMissingClient4This trap is sent when the Client 4 SFP transiever not is mounted. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.35 |
trm53005500TrapSfpBadTypeClient4This trap is sent when a unsupported Client 4 SFP is used. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.36 |
trm53005500TrapSfpFaultyClient4This trap is sent when the Client 4 SFP is faulty. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.37 |
trm53005500TrapTxGlitchClient4This trap is sent when a unit experiences a split second optical transmission glitch at the Client 4 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.38 |
trm53005500TrapRxGlitchClient4This trap is sent when a unit experiences a split second optical input power glitch at the Client 4 interface. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.39 |
trm53005500TrapTxDisabledClient4This trap is sent when the optical output power for the client 4 interface have been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.40 |
trm53005500TrapHwFailureThis trap is sent when the unit got a hardware failure. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.2.9.2.0.41 |
trmSubrackFM OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.3 |
trmSubrackTraps OBJECT IDENTIFIER .1.3.6.1.4.1.11857.1.2.3.0 |
trmTrapBmiLostThis trap is sent when communication with a unit is lost. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.3.0.1 |
trmTrapBmiErrorThis trap is sent when a internal BMI error occur. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.3.0.2 |
trmTrapHighTempThis trap is sent when a high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.3.0.3 |
trmTrapLowTempThis trap is sent when a low temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.3.0.4 |
trmTrapVeryHighTempThis trap is sent when a very high temperature alarm occurs on the NMB 6001 unit or a unit with temperature measurement. NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.3.0.5 |
trmTrapSpeedLimitExceededThis trap is sent if the Client bitrate is higher than a predefined protocol. When the alarm is activated Line and Client Tx is disabled. The alarm is ceased and Tx is enabled again at a lower value (hysteresis). Speed Limit is deactivated if Tx mode for the unit is disabled(2) or forcedon(3) NOTIFICATION-TYPE .1.3.6.1.4.1.11857.1.2.3.0.6 |