TIC-RMTI4-G9000-G2020-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
175
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
175 total| Object Name |
|---|
toshiba OBJECT IDENTIFIER .1.3.6.1.4.1.186 |
RFC1155-SMI Unknown .1.3.6.1.4.1.186 |
equ OBJECT IDENTIFIER .1.3.6.1.4.1.186.1 |
equUPS OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19 |
ticUPS OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2 |
rmti4 OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5 |
upsG9000-G2020 OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1 |
upsTrapFaultAlarm: One or more fault/status alarm(s) reported. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.1 |
upsTrapFaultClearAlarm Clear: One or more fault/status reported. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.2 |
upsTrapOnBatteryInfo: The UPS is on Battery Mode. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.3 |
upsTrapOnBatteryClearInfo Clear: The UPS is on Battery Mode. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.4 |
upsTrapBatteryLowWarning: Battery Low Voltage. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.5 |
upsTrapBatteryLowClearWarning Clear: Battery Low Voltage. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.6 |
upsTrapBatteryDepletedWarning: UPS contains depleted batteries, it will be unable to support critical loads. Shutdown excess equipment to reduce load. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.7 |
upsTrapBatteryDepletedClearWarning Clear: UPS contains depleted batteries, it will be unable to support critical loads. Shutdown excess equipment to reduce load.. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.8 |
upsTrapBatteryOverheatFault: Battery Overheat. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.9 |
upsTrapBatteryOverheatClearFault Clear: Battery Overheat. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.10 |
upsTrapBatteryVoltageAbnormalFault: Battery Voltage Abnormal. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.11 |
upsTrapBatteryVoltageAbnormalClearFault Clear: Battery Voltage Abnormal. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.12 |
upsTrapUPSOverheatFault: UPS Overheat, heatsinks temperature exceeds thermal settings. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.13 |
upsTrapUPSOverheatClearFault Clear: UPS Overheat, heatsinks temperature exceeds thermal settings. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.14 |
upsTrapPowerFailureInfo: Power Failure. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.15 |
upsTrapPowerFailureClearInfo Clear: PowerFailure. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.16 |
upsTrapUPSOverloadFault: UPS Overload (OL), the output load exceeds the rated current. Decrease load. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.17 |
upsTrapUPSOverloadClearFault Clear: UPS Overload (OL), the output load exceeds the rated current. Decrease load. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.18 |
upsTrapUserDefinedOverloadWarningWarning: The inverter output load % is greater than the user defined overload set point (default: 110%). TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.19 |
upsTrapUserDefinedOverloadWarningClearWarning Clear: The inverter output load % is greater than the user defined overload set point (default: 110%). TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.20 |
upsTrapOnBypassWarning:On Bypass. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.21 |
upsTrapOnBypassClearWarning Clear: On Bypass. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.22 |
upsTrapOutputOffInfo: The UPS output is off. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.23 |
upsTrapOutputOffClearInfo Clear: The UPS output is off. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.24 |
upsTrapAsyncOperationWarning: Inverter Synchronous. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.25 |
upsTrapAsyncOperationClearWarning Clear: Inverter Synchronous. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.26 |
upsTrapDCBusOverCurrentFault: DC Overcurrent (DCOC). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.27 |
upsTrapDCBusOverCurrentClearFault Clear: DC Overcurrent (DCOC). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.28 |
upsTrapDCBusOverVoltageFault: DC Overvoltage (DCOV). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.29 |
upsTrapDCBusOverVoltageClearFault Clear: DC Overvoltage (DCOV). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.30 |
upsTrapDCBusUnderVoltageFault: DC Undervoltage (DCUV). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.31 |
upsTrapDCBusUnderVoltageClearFault Clear: DC Undervoltage (DCUV). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.32 |
upsTrapDCBusImbalanceFault: DC Unbalance. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.33 |
upsTrapDCBusImbalanceClearFault Clear: DC Unbalance. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.34 |
upsTrapOutputUnderVoltageFault: Output Undervoltage. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.35 |
upsTrapOutputUnderVoltageClearFault Clear: Output Undervoltage. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.36 |
upsTrapOutputOverVoltageFault: Output Overvoltage (VLOV). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.37 |
upsTrapOutputOverVoltageClearFault Clear: Output Overvoltage (VLOV). Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.38 |
upsTrapInverterOverloadFault: UPS Overload, short time over-current has been detected during On-Line operation. Decrease Load. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.39 |
upsTrapInverterOverloadClearFault Clear: UPS Overload, short time over-current has been detected during On-Line operation. Decrease Load. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.40 |
upsTrapInverterOvercurrentFault: Inverter Overcurrent. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.41 |
upsTrapInverterOvercurrentClearFault Clear: Inverter Overcurrent. Contact your Toshiba authorized service center for examination. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.42 |
upsTrapRemotEyeCommErrorWarning: RemotEye UPS communication error. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.43 |
upsTrapRemotEyeCommErrorClearWarning Clear:RemotEye UPS communication error. TRAP-TYPE .1.3.6.1.4.1.186.1.19.2.5.1.0.44 |
upsIdent OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.1 |
upsIdentManufacturerThe name of the UPS manufacturer.ro DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.1.1 |
upsIdentTypeformThe UPS Model designation.ro DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.1.2 |
upsIdentUPSFirmwareVersionThe UPS firmware version.ro DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.1.3 |
upsIdentSysNameA string identifying the UPS. This object is
set by the administrator.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.1.4 |
upsIdentAttachedDevicesA string identifying the devices attached to the
output(s) of the UPS. This object is set by
the administrator.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.1.5 |
upsInput OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.2 |
upsInputNumOfPhasesNumber of input lines. This data is used by upsInputNumLines.ro NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.2.1 |
upsInputLLVoltageABThe input line to line voltage for AB in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.2.2 |
upsInputLLVoltageBCThe input line to line voltage for BC in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.2.3 |
upsInputLLVoltageCAThe input line to line voltage for CA in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.2.4 |
upsInputLLVoltagePercentABThe input line to line voltage percent for AB.ro NonNegativeInteger UNITS "Percentage" .1.3.6.1.4.1.186.1.19.2.5.1.2.5 |
upsInputLLVoltagePercentBCThe input line to line voltage percent for BC.ro NonNegativeInteger UNITS "Percentage" .1.3.6.1.4.1.186.1.19.2.5.1.2.6 |
upsInputLLVoltagePercentCAThe input line to line voltage percent for CA.ro NonNegativeInteger UNITS "Percentage" .1.3.6.1.4.1.186.1.19.2.5.1.2.7 |
upsInputCurrentPhaseAThe input phase current for Phase A.ro NonNegativeInteger UNITS "0.1 RMS Amps" .1.3.6.1.4.1.186.1.19.2.5.1.2.8 |
upsInputCurrentPhaseBThe input phase current unit for Phase B.ro NonNegativeInteger UNITS "0.1 RMS Amps" .1.3.6.1.4.1.186.1.19.2.5.1.2.9 |
upsInputCurrentPhaseCThe input phase current unit for Phase C.ro NonNegativeInteger UNITS "0.1 RMS Amps" .1.3.6.1.4.1.186.1.19.2.5.1.2.10 |
upsInputFrequencyThe input frequency unit 0.1 Hertz.ro NonNegativeInteger UNITS "0.1 Hertz" .1.3.6.1.4.1.186.1.19.2.5.1.2.11 |
upsInputActivePowerAThe magnitude of the present input true power for phase A.ro NonNegativeInteger UNITS "Watts" .1.3.6.1.4.1.186.1.19.2.5.1.2.12 |
upsInputActivePowerBThe magnitude of the present input true power for phase B.ro NonNegativeInteger UNITS "Watts" .1.3.6.1.4.1.186.1.19.2.5.1.2.13 |
upsInputActivePowerCThe magnitude of the present input true power for phase C.ro NonNegativeInteger UNITS "Watts" .1.3.6.1.4.1.186.1.19.2.5.1.2.14 |
upsInputTotalActivePowerThe magnitude of the total input true power.ro NonNegativeInteger UNITS "Watts" .1.3.6.1.4.1.186.1.19.2.5.1.2.15 |
upsInputRatedLLVoltageThe input line to line rated voltage in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.2.16 |
upsOutput OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.3 |
upsOutputSourceThe present source of output power. The enumeration
none(2) indicates that there is no source of output
power (and therefore no output power), for example,
the system has opened the output breaker.ro Enumeration .1.3.6.1.4.1.186.1.19.2.5.1.3.1 |
upsOutputNumOfPhasesThe number of output lines utilized in this device.ro NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.3.2 |
upsOutputLLVoltageABThe output line to line voltage for AB in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.3.3 |
upsOutputLLVoltageBCThe output line to line voltage for BC in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.3.4 |
upsOutputLLVoltageCAThe output line to line voltage for CA in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.3.5 |
upsOutputCurrentPhaseAThe Output phase current for phase A in amps.ro NonNegativeInteger UNITS "RMS Amps" .1.3.6.1.4.1.186.1.19.2.5.1.3.6 |
upsOutputCurrentPhaseBThe Output phase current for phase B in amps.ro NonNegativeInteger UNITS "RMS Amps" .1.3.6.1.4.1.186.1.19.2.5.1.3.7 |
upsOutputCurrentPhaseCThe Output phase current for phase C in amps.ro NonNegativeInteger UNITS "RMS Amps" .1.3.6.1.4.1.186.1.19.2.5.1.3.8 |
upsOutputFrequencyThe Output Frequency for phase A in 1/10 of HZ.ro NonNegativeInteger UNITS "0.1 Hertz" .1.3.6.1.4.1.186.1.19.2.5.1.3.9 |
upsOutputCurrentPercentAThe output current for phase A in percent.ro INTEGER UNITS "PERCENT" .1.3.6.1.4.1.186.1.19.2.5.1.3.10 |
upsOutputCurrentPercentBThe output current for phase B in percent.ro INTEGER UNITS "PERCENT" .1.3.6.1.4.1.186.1.19.2.5.1.3.11 |
upsOutputCurrentPercentCThe output current for phase C in percent.ro INTEGER UNITS "PERCENT" .1.3.6.1.4.1.186.1.19.2.5.1.3.12 |
upsOutputTotalActivePowerThe output active power.ro NonNegativeInteger UNITS "kWatts" .1.3.6.1.4.1.186.1.19.2.5.1.3.13 |
upsOutputTotalActivePowerPercentThe output active power in percent.ro NonNegativeInteger UNITS "percentage" .1.3.6.1.4.1.186.1.19.2.5.1.3.14 |
upsOutputPowerFactorThe UPS output power factor.ro NonNegativeInteger UNITS "0.01" .1.3.6.1.4.1.186.1.19.2.5.1.3.15 |
upsOutputRatedActivePowerThe output rated active power for the UPS.ro NonNegativeInteger UNITS "Watts" .1.3.6.1.4.1.186.1.19.2.5.1.3.16 |
upsOutputRatedApparentPowerThe output rated apparent power for the UPS.ro NonNegativeInteger UNITS "VA" .1.3.6.1.4.1.186.1.19.2.5.1.3.17 |
upsOutputRatedLLVoltageThe output rated line to line voltage for the UPS.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.3.18 |
upsBypass OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.4 |
upsBypassNumOfPhasesThe number of bypass lines utilized.ro NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.4.1 |
upsBypassLLVoltageABThe Bypass line to line voltage for AB in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.4.2 |
upsBypassLLVoltageBCThe Bypass line to line voltage for BC in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.4.3 |
upsBypassLLVoltageCAThe Bypass line to line voltage for CA in RMS volts.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.4.4 |
upsBypassFrequencyThe Bypass frequency in 0.1 Hertz.ro NonNegativeInteger UNITS "0.1 Hertz" .1.3.6.1.4.1.186.1.19.2.5.1.4.5 |
upsBattery OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.5 |
upsBatteryStatusThe indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run time sufficient to handle the load. A value of batteryLow indicates the battery level is low. Continued operation in battery mode will deplate batteries. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output). A value of batteryDischarging indicates UPS system is in Battery power.ro Enumeration .1.3.6.1.4.1.186.1.19.2.5.1.5.1 |
upsElapsedTimeOnBatteryPowerIf the unit is on battery power, the elapsed time
since the UPS on battery power, or the
time since the network management subsystem was last
restarted, whichever is less. Zero shall be returned
if the unit is not on battery power.ro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.186.1.19.2.5.1.5.2 |
upsEstimatedBatteryRuntimeAn estimate of the time to battery charge depletion
under the present load conditions if the utility power
is off and remains off, or if it were to be lost and
remain off.ro PositiveInteger UNITS "minutes" .1.3.6.1.4.1.186.1.19.2.5.1.5.3 |
upsBatteryVoltageThe battery voltage DC.ro NonNegativeInteger UNITS "Volt DC" .1.3.6.1.4.1.186.1.19.2.5.1.5.4 |
upsBatteryVoltagePercentBattery voltage in percent.ro NonNegativeInteger UNITS "percentage" .1.3.6.1.4.1.186.1.19.2.5.1.5.5 |
upsBatteryEstimatedChargeAn estimate of the charge to battery charge depletion
under the present load conditions if the utility power
is off and remains off, or if it were to be lost and
remain off.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.5.6 |
upsBatteryDischargeCurrentThe present battery discharge Current in percent.ro Integer32 UNITS "percentage" .1.3.6.1.4.1.186.1.19.2.5.1.5.7 |
upsBatteryChargeCurrentThe present battery charge Current in percent.ro Integer32 UNITS "percentage" .1.3.6.1.4.1.186.1.19.2.5.1.5.8 |
upsBatteryModelThe Battery manufacturer.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.5.9 |
upsBatteryInSeriesThe Battery rated holding time in minutes.rw NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.5.10 |
upsBatteryNumStringsThe Battery rated holding time in minutes.rw NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.5.11 |
upsBatteryRatedAmpereHourThe Battery rated holding time in minutes.rw NonNegativeInteger UNITS "Ampere Hour" .1.3.6.1.4.1.186.1.19.2.5.1.5.12 |
upsBatteryRatedBackupTimeThe Battery rated holding time in minutes.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.5.13 |
upsBatteryInstallationDateThe battery install date.ro DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.5.14 |
upsAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.6 |
upsAlarmsPresentThe present number of active alarm conditions.ro Gauge32 .1.3.6.1.4.1.186.1.19.2.5.1.6.1 |
upsAlarmTableA list of alarm table entries. The table contains
zero, one, or many rows at any moment, depending upon
the number of alarm conditions in effect. The table
is initially empty at agent startup. The agent
creates a row in the table each time a condition is
detected and deletes that row when that condition no
longer pertains. The agent creates the first row with
upsAlarmId equal to 1, and increments the value of
upsAlarmId each time a new row is created, wrapping to
the first free value greater than or equal to 1 when
the maximum value of upsAlarmId would otherwise be
exceeded. Consequently, after multiple operations,
the table may become sparse, e.g., containing entries
for rows 95, 100, 101, and 203 and the entries should
not be assumed to be in chronological order because
upsAlarmId might have wrapped.
Alarms are named by an OBJECT IDENTIFIER,
upsAlarmDescr, to allow a single table to
reflect well known alarms plus alarms defined by a
particular implementation, i.e., as documented in the
private enterprise MIB definition for the device. No
two rows will have the same value of upsAlarmDescr,
since alarms define conditions. In order to meet this
requirement, care should be taken in the definition of
alarm conditions to insure that a system cannot enter
the same condition multiple times simultaneously.
The number of rows in the table at any given time is
reflected by the value of upsAlarmsPresent. SEQUENCE OF UpsAlarmEntry .1.3.6.1.4.1.186.1.19.2.5.1.6.2 |
upsAlarmEntryAn entry containing information applicable to a
particular alarm. UpsAlarmEntry .1.3.6.1.4.1.186.1.19.2.5.1.6.2.1 |
upsAlarmIdA unique identifier for an alarm condition. This
value must remain constant. PositiveInteger .1.3.6.1.4.1.186.1.19.2.5.1.6.2.1.1 |
upsAlarmDescrA reference to an alarm description object. The
object referenced should not be accessible, but rather
be used to provide a unique description of the alarm
condition.ro AutonomousType (SNMPv2-TC) .1.3.6.1.4.1.186.1.19.2.5.1.6.2.1.2 |
upsAlarmTimeThe value of sysUpTime when the alarm condition was
detected. If the alarm condition was detected at the
time of agent startup and presumably existed before
agent startup, the value of upsAlarmTime shall equal 0.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.186.1.19.2.5.1.6.2.1.3 |
upsWellKnownAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.6.3 |
upsAlarmFaultFault: A UPS fault/Alarm condition exists.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.1 |
upsAlarmOnBatteryInfo: The UPS is on Battery mode; it is supplying output power from its batteries.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.2 |
upsAlarmBatteryLowWarning: The battery level is low. It has dropped to less than 90% of its nominal value. Continued operation in Battery Mode will deplete Batteries and result in UPS output shut down. Reduce critical load to increase battery runtime.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.3 |
upsAlarmBatteryDepletedWarning: UPS contains depleted batteries, it will be unable to support critical loads. Shut down excess equipment to reduce Load.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.4 |
upsAlarmBatteryOverheatFault: Detection of over temperature at the batteries.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.5 |
upsAlarmBatteryVoltageAbnormalFault: Battery voltage is abnormality.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.6 |
upsAlarmUPSOverheatFault: The UPS is overheating (warning is given when the internal temperature reaches and exceeds 50?C rise @ 40?C ambient). Check to see if the ambient temperature is abnormally high (40?C or more). If so, turn on air conditioning. Also, check ventilation fan at the back of the UPS for operation or obstructions. Otherwise, shut down the UPS and contact your Toshiba authorized service center.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.7 |
upsAlarmPowerFailureInfo: Power Failure.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.8 |
upsAlarmUPSOverloadFault: The UPS is overloaded. UPS will switch to bypass operation or shut down if no action is taken. Shut down excess equipment to reduce Load.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.9 |
upsAlarmUserDefinedOverloadWarningWarning: The inverter output load % is greater than the user defined overload set point (default: 110%).ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.10 |
upsAlarmOnBypassWarning: The UPS is in Stop (Bypass) mode.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.11 |
upsAlarmOutputOffInfo: The UPS output is off.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.12 |
upsAlarmAsyncOperationWarning: Async Operationro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.13 |
upsAlarmDCBusOverCurrentFault: UPS is reporting a DC bus overcurrent condition. Contact your Toshiba authorized service center for examination of a DCOC fault.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.14 |
upsAlarmDCBusOverVoltageFault: UPS is reporting a DC bus overvoltage condition. Contact your Toshiba authorized service center for examination of a DCOV fault.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.15 |
upsAlarmDCBusUnderVoltageFault: UPS is reporting a DC bus undervoltage condition. Contact your
Toshiba authorized service center for examination of a DCUV fault.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.16 |
upsAlarmDCBusImbalancedFault: The DC imbalanced alarm detection.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.17 |
upsAlarmOutputUnderVoltageFault: UPS is reporting an output undervoltage condition. Contact your Toshiba authorized service center for examination of a INVUV fault.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.18 |
upsAlarmOutputOverVoltageFault: UPS is reporting an output overvoltage condition. Contact your
Toshiba authorized service center for examination of a INVOV fault.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.19 |
upsAlarmInverterOverloadFault: Short time over-current has been detected.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.20 |
upsAlarmInverterOvercurrentFault: Detection of inverter overcurrent.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.21 |
upsAlarmRemotEyeCommErrorWarning: Communication error between the RemotEye 4 and the UPS.ro INTEGER .1.3.6.1.4.1.186.1.19.2.5.1.6.3.22 |
upsConfig OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.7 |
upsConfigModelIDStringUPS Model ID string. This string contains codes for the UPS series,input voltage, output voltage, output VA, and addition option.ro DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.7.1 |
upsConfigUPSFirmwareVersionThe G9000 software version.ro DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.7.2 |
upsConfigInputNumOfPhasesNumber of input lines. This data is used by upsInputNumLines.ro NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.7.3 |
upsConfigRatedInputFrequencyThe nominal input frequency. On those systems which
support read-write access to this object, if there is
an attempt to set this variable to a value that is not
supported, the request must be rejected and the agent
shall respond with an appropriate error message, i.e.,
badValue for SNMPv1, or inconsistentValue for SNMPv2.ro NonNegativeInteger UNITS "0.1 Hertz" .1.3.6.1.4.1.186.1.19.2.5.1.7.4 |
upsConfigRatedInputLLVoltageThe magnitude of the nominal input voltage. On those
systems which support read-write access to this
object, if there is an attempt to set this variable to
a value that is not supported, the request must be
rejected and the agent shall respond with an
appropriate error message, i.e., badValue for SNMPv1,
or inconsistentValue for SNMPv2.rw NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.7.5 |
upsConfigRatedInputPowerFactorUNITS are in hundredths. For 0.95 = 95.ro PositiveInteger UNITS "0.01" .1.3.6.1.4.1.186.1.19.2.5.1.7.6 |
upsConfigOutputNumOfPhasesNumber of output lines. This data is used by upsOutputNumLines.ro NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.7.7 |
upsConfigRatedOutputFrequencyThe nominal output frequency. On those systems which
support read-write access to this object, if there is
an attempt to set this variable to a value that is not
supported, the request must be rejected and the agent
shall respond with an appropriate error message, i.e.,
bad Value for SNMPv1, or inconsistent Value for SNMPv2.ro NonNegativeInteger UNITS "0.1 Hertz" .1.3.6.1.4.1.186.1.19.2.5.1.7.8 |
upsConfigRatedOutputLLVoltageThe magnitude of the nominal output voltage. On
those systems which support read-write access to this
object, if there is an attempt to set this variable to
a value that is not supported, the request must be
rejected and the agent shall respond with an
appropriate error message, i.e., bad Value for SNMPv1,
or inconsistent Value for SNMPv2.rw NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.186.1.19.2.5.1.7.9 |
upsConfigRatedOutputApperentPowerThe magnitude of the nominal Volt-Amp rating.ro NonNegativeInteger UNITS "Volt-Amps" .1.3.6.1.4.1.186.1.19.2.5.1.7.10 |
upsConfigRatedOutputActivePowerThe magnitude of the nominal true power rating.ro NonNegativeInteger UNITS "KWatts" .1.3.6.1.4.1.186.1.19.2.5.1.7.11 |
upsConfigRatedOutputPowerFactorUNITS are in hundredths. For 0.70 = 70.ro NonNegativeInteger UNITS "0.01" .1.3.6.1.4.1.186.1.19.2.5.1.7.12 |
upsConfigBypassNumOfPhasesThe number of bypass lines utilized.ro NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.7.13 |
upsConfigLowVoltageTransferPointThe minimum input line voltage allowed before the UPS
system transfers to battery backup.rw NonNegativeInteger UNITS "percentage" .1.3.6.1.4.1.186.1.19.2.5.1.7.14 |
upsConfigHighVoltageTransferPointThe maximum line voltage allowed before the UPS
system transfers to battery backup.rw NonNegativeInteger UNITS "percentage" .1.3.6.1.4.1.186.1.19.2.5.1.7.15 |
upsConfigBatteryInSeriesThe number of batteries in each string connected in series.rw NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.7.16 |
upsConfigBatteryNumStringsThe number of parallel battery strings.rw NonNegativeInteger .1.3.6.1.4.1.186.1.19.2.5.1.7.17 |
upsConfigRatedBatteryVoltageRated voltage of a single battery.rw NonNegativeInteger UNITS "Volts DC" .1.3.6.1.4.1.186.1.19.2.5.1.7.18 |
upsConfigRatedBatteryAmpereHourThe rated battery in ampere hour.rw INTEGER UNITS "Ahr" .1.3.6.1.4.1.186.1.19.2.5.1.7.19 |
upsConfigBatteryModelThe manufacturer of the battery.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.7.20 |
upsConfigBatteryRatedBackupTimeThe rated duration batteries can hold when unit is in backup mode with full load.rw NonNegativeInteger UNITS "minutes" .1.3.6.1.4.1.186.1.19.2.5.1.7.21 |
upsConfigUserDefinedOverloadSetPointThe maximum output load % defined by the user.rw INTEGER UNITS "%" .1.3.6.1.4.1.186.1.19.2.5.1.7.22 |
upsConfigBatteryInstallationDateThe battery install date.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.7.23 |
upsConfigSysNameA string identifying the UPS. This object is
set by the administrator.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.7.24 |
upsConfigAttachedDevicesA string identifying the devices attached to the
output(s) of the UPS. This object is set by
the administrator.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.7.25 |
upsConfigPasswordPassword.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.7.26 |
upsTime OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.8 |
upsTimeRealDatePresent date: year-month-date-day of the week.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.8.1 |
upsTimeRealTimePresent time (military format): hour-minute-second. For example,2:00pm would be 14:00:00.rw DisplayString .1.3.6.1.4.1.186.1.19.2.5.1.8.2 |
upsTrap OBJECT IDENTIFIER .1.3.6.1.4.1.186.1.19.2.5.1.9 |