Home/Catalog/T7511-MIB

T7511-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

61
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

61 total
Object Name
comet
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626
RFC1155-SMI
Unknown
.1.3.6.1.4.1.22626
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1
t7511
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1.2
readings
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1.2.1
temperatureTemperaturero
DisplayString
.1.3.6.1.4.1.22626.1.2.1.1
humidityHumidityro
DisplayString
.1.3.6.1.4.1.22626.1.2.1.2
computedValueComputed valuero
DisplayString
.1.3.6.1.4.1.22626.1.2.1.3
pressurePressurero
DisplayString
.1.3.6.1.4.1.22626.1.2.1.4
settings
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1.2.2
templowTemperature Limit Lowro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.1
temphighTemperature Limit Highro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.2
humiditylowHumidity Limit Lowro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.3
humidityhighHumidity Limit Highro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.4
cvlowComputed Value Limit Lowro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.5
cvhighComputed Value Limit Highro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.6
temptimeTemperature alaram delayro
INTEGER
.1.3.6.1.4.1.22626.1.2.2.7
humidityTimeHumidity alaram delayro
INTEGER
.1.3.6.1.4.1.22626.1.2.2.8
cvTimeComputed value alaram delayro
INTEGER
.1.3.6.1.4.1.22626.1.2.2.9
tempHystTemperature hysteresisro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.10
humidityHystHumidity hysteresisro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.11
cvHystComputed value hysteresisro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.12
presslowPressure Limit Lowro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.13
presshighPressure Limit Highro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.14
presstimePressure alaram delayro
INTEGER
.1.3.6.1.4.1.22626.1.2.2.15
pressureHystPressure hysteresisro
DisplayString
.1.3.6.1.4.1.22626.1.2.2.16
readingsint
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1.2.3
temperatureiTemperature *10ro
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.3.1
humidityiHumidity *10ro
INTEGER
.1.3.6.1.4.1.22626.1.2.3.2
cviComputed Value *10ro
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.3.3
pressureiPressure *10ro
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.3.4
settingsint
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1.2.4
templowiTemperature Limit Low *10rw
INTEGER
.1.3.6.1.4.1.22626.1.2.4.1
temphighiTemperature Limit High *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.2
humiditylowiHumidity Limit Low *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.3
humidityhighiHumidity Limit High *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.4
cvlowiComputed value Limit Low *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.5
cvhighiComputed value Limit High *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.6
temptimeiTemperature alaram delayrw
INTEGER
.1.3.6.1.4.1.22626.1.2.4.7
humidityTimeiHumidity alaram delayrw
INTEGER
.1.3.6.1.4.1.22626.1.2.4.8
cvTimeiComputed value alaram delayrw
INTEGER
.1.3.6.1.4.1.22626.1.2.4.9
tempHystiTemperature hysteresis *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.10
humidityHystiHumidity hysteresis *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.11
cvHystiComputed value hysteresis *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.12
presslowiPressure Limit Low *10rw
INTEGER
.1.3.6.1.4.1.22626.1.2.4.13
presshighiPressure Limit High *10rw
INTEGER
.1.3.6.1.4.1.22626.1.2.4.14
presstimeiPressure alaram delayrw
INTEGER
.1.3.6.1.4.1.22626.1.2.4.15
pressHystiPressure hysteresis *10rw
INTEGER(-2000..6000)
.1.3.6.1.4.1.22626.1.2.4.16
traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1.2.5
messageStringMessage giving more detailed information on alarms.ro
DisplayString
.1.3.6.1.4.1.22626.1.2.5.1
alarmTemperatureTemperature alarm 0 = temperature OK 1 = temperature too high 2 = temperature too lowro
INTEGER
.1.3.6.1.4.1.22626.1.2.5.2
alarmhumidityHumidity alarm 0 = humidity OK 1 = humidity too high 2 = humidity too lowro
INTEGER
.1.3.6.1.4.1.22626.1.2.5.3
alarmCvComputed value alarm 0 = Computed value OK 1 = Computed value too high 2 = Computed value too lowro
INTEGER
.1.3.6.1.4.1.22626.1.2.5.4
alarmPressurePressure alarm 0 = Computed value OK 1 = Computed value too high 2 = Computed value too lowro
INTEGER
.1.3.6.1.4.1.22626.1.2.5.5
tables
OBJECT IDENTIFIER
.1.3.6.1.4.1.22626.1.2.6
historyTableTable of the history values.
SEQUENCE OF HistoryEntry
.1.3.6.1.4.1.22626.1.2.6.1
historyEntryHistory values entries.
HistoryEntry
.1.3.6.1.4.1.22626.1.2.6.1.1
histtemperatureTemperature reading.ro
INTEGER
.1.3.6.1.4.1.22626.1.2.6.1.1.1
histhumidityHumidity reading.ro
INTEGER
.1.3.6.1.4.1.22626.1.2.6.1.1.2
histcomputedValueComputed value reading.ro
INTEGER
.1.3.6.1.4.1.22626.1.2.6.1.1.3
histpressurePressure reading.ro
INTEGER
.1.3.6.1.4.1.22626.1.2.6.1.1.4