SYNOLOGY-UPS-MIB
AI MIB Summary
SYNOLOGY-UPS-MIB defines the SNMP objects for monitoring Synology NAS devices equipped with UPS modules, exposing real-time metrics such as battery charge percentage, remaining runtime, input/output voltage, and current UPS status states. This module enables centralized network management systems to track power supply health and trigger alerts for battery degradation or power loss events on Synology hardware.
Characteristics of the ups information
Main OID:
synoUPS.1.3.6.1.4.1.6574.4
159
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
159 total| Object Name |
|---|
synology OBJECT IDENTIFIER .1.3.6.1.4.1.6574 |
synoUPSCharacteristics of the ups information MODULE-IDENTITY .1.3.6.1.4.1.6574.4 |
upsDevice OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.1 |
upsDeviceModelDevice modelro DisplayString .1.3.6.1.4.1.6574.4.1.1 |
upsDeviceManufacturerDevice manufacturerro DisplayString .1.3.6.1.4.1.6574.4.1.2 |
upsDeviceSerialDevice serial number.ro DisplayString .1.3.6.1.4.1.6574.4.1.3 |
upsDeviceTypeDevice type (ups, pdu, scd, psu)ro DisplayString .1.3.6.1.4.1.6574.4.1.4 |
upsDeviceDescriptionDevice description.ro DisplayString .1.3.6.1.4.1.6574.4.1.5 |
upsDeviceContactDevice administrator name.ro DisplayString .1.3.6.1.4.1.6574.4.1.6 |
upsDeviceLocationDevice physical location.ro DisplayString .1.3.6.1.4.1.6574.4.1.7 |
upsDevicePartDevice part number.ro DisplayString .1.3.6.1.4.1.6574.4.1.8 |
upsDeviceMACAddrPhysical network address of the device.ro DisplayString .1.3.6.1.4.1.6574.4.1.9 |
upsInfo OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2 |
upsInfoStatusUPS status.ro DisplayString .1.3.6.1.4.1.6574.4.2.1 |
upsInfoAlarmUPS alarmsro DisplayString .1.3.6.1.4.1.6574.4.2.2 |
upsInfoTimeInternal UPS clock timero DisplayString .1.3.6.1.4.1.6574.4.2.3 |
upsInfoDateInternal UPS clock datero DisplayString .1.3.6.1.4.1.6574.4.2.4 |
upsInfoModelUPS modelro DisplayString .1.3.6.1.4.1.6574.4.2.5 |
upsInfoMfr OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.6 |
upsInfoMfrNameUPS manufacturerro DisplayString .1.3.6.1.4.1.6574.4.2.6.1 |
upsInfoMfrDateUPS manufacturing datero DisplayString .1.3.6.1.4.1.6574.4.2.6.2 |
upsInfoSerialUPS serial numberro DisplayString .1.3.6.1.4.1.6574.4.2.7 |
upsInfoVendorIDVendor ID for USB devicesro DisplayString .1.3.6.1.4.1.6574.4.2.8 |
upsInfoProductIDProduct ID for USB devicesro DisplayString .1.3.6.1.4.1.6574.4.2.9 |
upsInfoFirmware OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.10 |
upsInfoFirmwareNameUPS firmwarero DisplayString .1.3.6.1.4.1.6574.4.2.10.1 |
upsInfoFirmwareAuxAuxiliary device firmwarero DisplayString .1.3.6.1.4.1.6574.4.2.10.2 |
upsInfoTemperatureUPS temperature (degrees C)ro Float UNITS "degree C" .1.3.6.1.4.1.6574.4.2.11 |
upsInfoLoad OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.12 |
upsInfoLoadValueLoad on UPS (percent)ro Float UNITS "percentage" .1.3.6.1.4.1.6574.4.2.12.1 |
upsInfoLoadHighLoad when UPS switches to overload condition (OVER) (percent)ro Float UNITS "percentage" .1.3.6.1.4.1.6574.4.2.12.2 |
upsInfoIDUPS system identifierro DisplayString .1.3.6.1.4.1.6574.4.2.13 |
upsInfoDelay OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.14 |
upsInfoDelayStartInterval to wait before restarting the load (seconds)ro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.6574.4.2.14.1 |
upsInfoDelayRebootInterval to wait before rebooting the UPS (seconds)ro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.6574.4.2.14.2 |
upsInfoDelayShutdownInterval to wait after shutdown with delay command (seconds)ro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.6574.4.2.14.3 |
upsInfoTimer OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.15 |
upsInfoTimerStartTime before the load will be started (seconds)ro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.6574.4.2.15.1 |
upsInfoTimerRebootTime before the load will be rebooted (seconds)ro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.6574.4.2.15.2 |
upsInfoTimerShutdownTime before the load will be shutdown (seconds)ro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.6574.4.2.15.3 |
upsInfoTest OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.16 |
upsInfoTestIntervalInterval between self testsro NonNegativeInteger UNITS "seconds" .1.3.6.1.4.1.6574.4.2.16.1 |
upsInfoTestResultResults of last self testro DisplayString .1.3.6.1.4.1.6574.4.2.16.2 |
upsInfoDisplayLanguageLanguage to use on front panelro DisplayString .1.3.6.1.4.1.6574.4.2.17 |
upsInfoContactsUPS external contact sensorsro DisplayString .1.3.6.1.4.1.6574.4.2.18 |
upsInfoEffciencyEfficiency of the UPS (ratio of the output current on the input current) (percent)ro NonNegativeInteger UNITS "percent" .1.3.6.1.4.1.6574.4.2.19 |
upsInfoPower OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.20 |
upsInfoPowerValueCurrent value of apparent power (Volt-Amps)ro Float UNITS "Volt-Amps" .1.3.6.1.4.1.6574.4.2.20.1 |
upsInfoPowerNominalNominal value of apparent power (Volt-Amps)ro Float UNITS "Volt-Amps" .1.3.6.1.4.1.6574.4.2.20.2 |
upsInfoRealPower OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.21 |
upsInfoRealPowerValueCurrent value of real power (Watts)ro Float UNITS "Watts" .1.3.6.1.4.1.6574.4.2.21.1 |
upsInfoRealPowerNominalNominal value of real power (Watts)ro Float UNITS "Watts" .1.3.6.1.4.1.6574.4.2.21.2 |
upsInfoBeeperStatusUPS beeper status (enabled, disabled or muted)ro DisplayString .1.3.6.1.4.1.6574.4.2.22 |
upsInfoTypeUPS typero DisplayString .1.3.6.1.4.1.6574.4.2.23 |
upsInfoWatchdogStatusUPS watchdog status (enabled or disabled)ro DisplayString .1.3.6.1.4.1.6574.4.2.24 |
upsInfoStart OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.2.25 |
upsInfoStartAutoUPS starts when mains is (re)appliedro DisplayString .1.3.6.1.4.1.6574.4.2.25.1 |
upsInfoStartBatteryAllow to start UPS from batteryro DisplayString .1.3.6.1.4.1.6574.4.2.25.2 |
upsInfoStartRebootUPS coldstarts from battery (enabled or disabled)ro DisplayString .1.3.6.1.4.1.6574.4.2.25.3 |
upsBattery OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.3 |
upsBatteryCharge OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.3.1 |
upsBatteryChargeValueBattery chargero Float UNITS "Percent" .1.3.6.1.4.1.6574.4.3.1.1 |
upsBatteryChargeLowRemaining battery level when UPS switches to LB (percent)ro Float UNITS "Percent" .1.3.6.1.4.1.6574.4.3.1.2 |
upsBatteryChargeRestartMinimum battery level for UPS restart after power-offro Float UNITS "Percent" .1.3.6.1.4.1.6574.4.3.1.3 |
upsBatteryChargeWarningBattery level when UPS switches to Warning state (percent)ro Float UNITS "Percent" .1.3.6.1.4.1.6574.4.3.1.4 |
upsBatteryVoltage OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.3.2 |
upsBatteryVoltageValueThe magnitude of the present battery voltage.ro Float UNITS "Volt DC" .1.3.6.1.4.1.6574.4.3.2.1 |
upsBatteryVoltageNominalNominal battery voltage.ro Float UNITS "Volt DC" .1.3.6.1.4.1.6574.4.3.2.2 |
upsBatteryVoltageLowMinimum battery voltage, that triggers FSD status .ro Float UNITS "Volt DC" .1.3.6.1.4.1.6574.4.3.2.3 |
upsBatteryVoltageHighMaximum battery voltage (Ie battery.charge = 100).ro Float UNITS "Volt DC" .1.3.6.1.4.1.6574.4.3.2.4 |
upsBatteryCapacityBattery capacity (Ah)ro Float UNITS "A" .1.3.6.1.4.1.6574.4.3.3 |
upsBatteryCurrentThe present battery current.ro Float UNITS "Amp DC" .1.3.6.1.4.1.6574.4.3.4 |
upsBatteryTemperatureThe ambient temperature at or near the UPS Battery casing.ro Float UNITS "degrees Centigrade" .1.3.6.1.4.1.6574.4.3.5 |
upsBatteryRuntime OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.3.6 |
upsBatteryRuntimeValueBattery runtime (seconds)ro NonNegativeInteger UNITS "Seconds" .1.3.6.1.4.1.6574.4.3.6.1 |
upsBatteryRuntimeLowRemaining battery runtime when UPS switches to LB (seconds)ro NonNegativeInteger UNITS "Seconds" .1.3.6.1.4.1.6574.4.3.6.2 |
upsBatteryRuntimeRestartMinimum battery runtime for UPS restart after power-off (seconds)ro NonNegativeInteger UNITS "Seconds" .1.3.6.1.4.1.6574.4.3.6.3 |
upsBatteryAlarmThresholdBattery alarm thresholdro DisplayString .1.3.6.1.4.1.6574.4.3.7 |
upsBatteryDateBattery change datero DisplayString .1.3.6.1.4.1.6574.4.3.8 |
upsBatteryMfrDateBattery manufacturing datero DisplayString .1.3.6.1.4.1.6574.4.3.9 |
upsBatteryPacksNumber of battery packsro NonNegativeInteger .1.3.6.1.4.1.6574.4.3.10 |
upsBatteryPacksBadNumber of bad battery packsro NonNegativeInteger .1.3.6.1.4.1.6574.4.3.11 |
upsBatteryTypeBattery chemistryro DisplayString .1.3.6.1.4.1.6574.4.3.12 |
upsBatteryProtectionPrevent deep discharge of batteryro DisplayString .1.3.6.1.4.1.6574.4.3.13 |
upsBatteryEnergySaveSwitch off when running on battery and no/low loadro DisplayString .1.3.6.1.4.1.6574.4.3.14 |
upsInput OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.4 |
upsInputVoltage OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.4.1 |
upsInputVoltageValueInput voltagero Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.1.1 |
upsInputVoltageMaxMaximum incoming voltage seenro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.1.2 |
upsInputVoltageMinMinimum incoming voltage seenro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.1.3 |
upsInputVoltageNominalNominal input voltagero Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.1.4 |
upsInputVoltageExtendExtended input voltage rangero DisplayString .1.3.6.1.4.1.6574.4.4.1.5 |
upsInputVoltageFaultInput voltage Faultro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.1.6 |
upsInputTransfer OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.4.2 |
upsInputTransferReasonReason for last transfer to batteryro DisplayString .1.3.6.1.4.1.6574.4.4.2.1 |
upsInputTransferLowLow voltage transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.2 |
upsInputTransferHighHigh voltage transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.3 |
upsInputTransferLowMinsmallest settable low voltage transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.4 |
upsInputTransferLowMaxgreatest settable low voltage transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.5 |
upsInputTransferHighMinsmallest settable high voltage transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.6 |
upsInputTransferHighMaxgreatest settable high voltage transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.7 |
upsInputTransferBoostLowLow voltage boosting transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.8 |
upsInputTransferBoostHighHigh voltage boosting transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.9 |
upsInputTransferTrimLowLow voltage trimming transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.10 |
upsInputTransferTrimHighHigh voltage trimming transfer pointro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.4.2.11 |
upsInputSensitivityInput power sensitivityro DisplayString .1.3.6.1.4.1.6574.4.4.3 |
upsInputQualityInput power qualityro DisplayString .1.3.6.1.4.1.6574.4.4.4 |
upsInputCurrent OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.4.5 |
upsInputCurrentValueInput current (A)ro Float UNITS "Amp" .1.3.6.1.4.1.6574.4.4.5.1 |
upsInputCurrentNominalNominal input current (A)ro Float UNITS "Amp" .1.3.6.1.4.1.6574.4.4.5.2 |
upsInputFrequency OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.4.6 |
upsInputFrequencyValueInput line frequency (Hz)ro Float UNITS "Hz" .1.3.6.1.4.1.6574.4.4.6.1 |
upsInputFrequencyNominalNominal input line frequency (Hz)ro Float UNITS "Hz" .1.3.6.1.4.1.6574.4.4.6.2 |
upsInputFrequencyLowInput line frequency low (Hz)ro Float UNITS "Hz" .1.3.6.1.4.1.6574.4.4.6.3 |
upsInputFrequencyHighInput line frequency high (Hz)ro Float UNITS "Hz" .1.3.6.1.4.1.6574.4.4.6.4 |
upsInputFrequencyExtendExtended input frequency rangero DisplayString .1.3.6.1.4.1.6574.4.4.6.5 |
upsOutput OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.5 |
upsOutputVoltage OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.5.1 |
upsOutputVoltageValueOutput voltage (V)ro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.5.1.1 |
upsOutputVoltageNominalNominal output voltage (V)ro Float UNITS "Volts" .1.3.6.1.4.1.6574.4.5.1.2 |
upsOutputFrequency OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.5.2 |
upsOutputFrequencyValueOutput frequency (Hz)ro Float UNITS "Hz" .1.3.6.1.4.1.6574.4.5.2.1 |
upsOutputFrequencyNominalNominal output frequency (Hz)ro Float UNITS "Hz" .1.3.6.1.4.1.6574.4.5.2.2 |
upsOutputCurrent OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.5.3 |
upsOutputCurrentValueOutput current (A)ro Float UNITS "Amp" .1.3.6.1.4.1.6574.4.5.3.1 |
upsOutputCurrentNominalNominal output current (A)ro Float UNITS "Amp" .1.3.6.1.4.1.6574.4.5.3.2 |
upsAmbient OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.6 |
upsAmbientTemperature OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.6.1 |
upsAmbientTemperatureValueAmbient temperature (degrees C)ro Float UNITS "degrees Centigrade" .1.3.6.1.4.1.6574.4.6.1.1 |
upsAmbientTemperatureAlarmTemperature alarm (enabled/disabled)ro DisplayString .1.3.6.1.4.1.6574.4.6.1.2 |
upsAmbientTemperatureHighTemperature threshold high (degrees C)ro Float UNITS "degrees Centigrade" .1.3.6.1.4.1.6574.4.6.1.3 |
upsAmbientTemperatureLowTemperature threshold low (degrees C)ro Float UNITS "degrees Centigrade" .1.3.6.1.4.1.6574.4.6.1.4 |
upsAmbientTemperatureMaxMaximum temperature seen (degrees C)ro Float UNITS "degrees Centigrade" .1.3.6.1.4.1.6574.4.6.1.5 |
upsAmbientTemperatureMinMinimum temperature seen (degrees C)ro Float UNITS "degrees Centigrade" .1.3.6.1.4.1.6574.4.6.1.6 |
upsAmbientHumidity OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.6.2 |
upsAmbientHumidityValueAmbient relative humidity (percent)ro Float UNITS "percent" .1.3.6.1.4.1.6574.4.6.2.1 |
upsAmbientHumidityAlarmRelative humidity alarm (enabled/disabled)ro DisplayString .1.3.6.1.4.1.6574.4.6.2.2 |
upsAmbientHumidityHighRelative humidity threshold high (percent)ro Float UNITS "percent" .1.3.6.1.4.1.6574.4.6.2.3 |
upsAmbientHumidityLowRelative humidity threshold low (percent)ro Float UNITS "percent" .1.3.6.1.4.1.6574.4.6.2.4 |
upsAmbientHumidityMaxMaximum relative humidity seen (percent)ro Float UNITS "percent" .1.3.6.1.4.1.6574.4.6.2.5 |
upsAmbientHumidityMinMinimum relative humidity seen (percent)ro Float UNITS "percent" .1.3.6.1.4.1.6574.4.6.2.6 |
upsDriver OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.7 |
upsDriverNameDriver namero DisplayString .1.3.6.1.4.1.6574.4.7.1 |
upsDriverVersionDriver version (NUT release)ro DisplayString .1.3.6.1.4.1.6574.4.7.2 |
upsDriverVersionDataDriver version dataro DisplayString .1.3.6.1.4.1.6574.4.7.3 |
upsDriverVersionInternalInternal driver version (if tracked separately)ro DisplayString .1.3.6.1.4.1.6574.4.7.4 |
upsDriverPollIntervalPoll interval setup in configuration filero Integer32 UNITS "second" .1.3.6.1.4.1.6574.4.7.5 |
upsDriverPortPort setup in configuration filero DisplayString .1.3.6.1.4.1.6574.4.7.6 |
upsDriverPollFrequencyPoll frequencyro Integer32 .1.3.6.1.4.1.6574.4.7.7 |
upsDriverProductIDProduct IDro DisplayString .1.3.6.1.4.1.6574.4.7.8 |
upsDriverSnmpVersionSnmp versionro DisplayString .1.3.6.1.4.1.6574.4.7.9 |
upsServer OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.8 |
upsServerInfoServer informationro DisplayString .1.3.6.1.4.1.6574.4.8.1 |
upsServerVersionServer versionro DisplayString .1.3.6.1.4.1.6574.4.8.2 |
upsConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.9 |
upsCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.9.1 |
upsComplianceThe compliance statement for synoSystem entities which implement the SYNOLOGY SYSTEM MIB. Unknown .1.3.6.1.4.1.6574.4.9.1.1 |
upsGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6574.4.9.2 |
upsGroupA collection of objects providing basic information of an synology ups entity. Unknown .1.3.6.1.4.1.6574.4.9.2.1 |