Home/Catalog/SYNC-RESEARCH-MIB

SYNC-RESEARCH-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for SYNC-RESEARCH-MIB.

398
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

398 total
Object Name
syncResearch
OBJECT IDENTIFIER
.1.3.6.1.4.1.485
RFC1155-SMI
Unknown
.1.3.6.1.4.1.485
configChangedThis trap indicates that the configuration of the unit has been changed.
TRAP-TYPE
.1.3.6.1.4.1.485.0.800
configErrorThis trap indicates that the activation of configuration of the unit has resulted in an error. New configuration has not been successfully activated.
TRAP-TYPE
.1.3.6.1.4.1.485.0.801
dumpExistsThis trap indicates that a memory core dump exists.
TRAP-TYPE
.1.3.6.1.4.1.485.0.802
dumpArchivedThis trap indicates that the memory dump file has been archived.
TRAP-TYPE
.1.3.6.1.4.1.485.0.803
lineStatusChangedThis trap indicates that the indicated Line or Port has changed state. It has either been enabled, failed or disabled.
TRAP-TYPE
.1.3.6.1.4.1.485.0.804
lanStatusChangedThis trap indicates that the indicated LAN Port has changed state. It has either been enabled, failed or disabled.
TRAP-TYPE
.1.3.6.1.4.1.485.0.805
lineQuality
TRAP-TYPE
.1.3.6.1.4.1.485.0.806
puStatusChangedThis trap indicates that the indicated PU has changed state. It has either been enabled, failed or disabled.
TRAP-TYPE
.1.3.6.1.4.1.485.0.807
puConnectionStatusChangedNote this trap is obsolete. This trap indicates that the indicated PU has changed connection state. Its connection has either been established, disconnected, or rejected.
TRAP-TYPE
.1.3.6.1.4.1.485.0.808
netviewConnectionStatusChangedNote this trap is obsolete. This trap indicates that the NetView PU has changed connection state. Its connection has either been established, disconnected, or rejected.
TRAP-TYPE
.1.3.6.1.4.1.485.0.809
netviewAltConnectionStatusChangedNote this trap is obsolete. This trap indicates that the Alternate NetView PU has changed connection state. Its connection has either been established, disconnected, or rejected.
TRAP-TYPE
.1.3.6.1.4.1.485.0.810
puConnectionStatusUpThis trap indicates that the indicated PU has changed connection state. Its connection had been established.
TRAP-TYPE
.1.3.6.1.4.1.485.0.811
puConnectionStatusDownThis trap indicates that the indicated PU has changed connection state. Its connection has been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the puLastClearCode.
TRAP-TYPE
.1.3.6.1.4.1.485.0.812
netviewConnectionStatusUpThis trap indicates that the indicated NetView PU has changed connection state. Its connection has been established.
TRAP-TYPE
.1.3.6.1.4.1.485.0.813
netviewConnectionStatusDownThis trap indicates that the indicated NetView PU has changed connection state. Its connection had been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the netviewLastClearCode.
TRAP-TYPE
.1.3.6.1.4.1.485.0.814
netviewAltConnectionStatusUpThis trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection has been established.
TRAP-TYPE
.1.3.6.1.4.1.485.0.815
netviewAltConnectionStatusDownThis trap indicates that the indicated Alternate NetView PU has changed connection state. Its connection had been disconnected. If the indicated PU is not in session, the trap is generated only if the clear code is different from the netviewAltLastClearCode.
TRAP-TYPE
.1.3.6.1.4.1.485.0.816
syncResearchAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1
syncProducts
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1
boundary
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.1
syncCN2R2b
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.1.1
syncFN2R2b
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.1.2
syncCN4R2b
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.1.3
syncFN4R2b
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.1.4
syncQN4R2b
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.1.5
centralSite
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.2
syncCN4R2c
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.2.1
syncFN4R2c
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.2.2
syncQN4R2c
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.1.2.3
oemProducts
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2
threeCom
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.1
linkConverter
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.1.1
cableTron
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.2
oemSNACXR2C
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.2.1
oemSNACXR2W
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.2.2
oemSNACMR2C
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.2.3
oemSNACMR2W
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.2.4
chipcom
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.1.2.3
srCommTrapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.2
commCountThe number of possible community name entries in the table.ro
INTEGER
.1.3.6.1.4.1.485.2.1
commTableThis table houses the information for trivial authentication and sending traps.
SEQUENCE OF CommEntry
.1.3.6.1.4.1.485.2.2
commEntryEach entry contains a community name and access code for SNMP trivial authenticationm an enable/disable traps options, as well as network and physical addressing information for traps.
CommEntry
.1.3.6.1.4.1.485.2.2.1
commIndexA unique value for each community entry. Its value ranges between 1 and commCount.ro
INTEGER
.1.3.6.1.4.1.485.2.2.1.1
commNameA community name that will be used to access MIB objects within the device. Each community name is associated with an access code of either NO_ACCESS, RO, RW, or SU.rw
OCTET STRING
.1.3.6.1.4.1.485.2.2.1.2
commTrapThis object is checked to determine if traps should be sent to the corresponding network address associated with it.rw
Enumeration
.1.3.6.1.4.1.485.2.2.1.3
commIPAddrThe network address of the device that will receive traps from the agent. This IP address also qualifies who may use this community name to access MIB objects. If this community name is use by some one with a different IP address, an Authentication Trap will be generated. If the IP address is set to 0.0.0.0, anyone may use this address, however, traps will not be sent since the address is invalid.rw
IpAddress
.1.3.6.1.4.1.485.2.2.1.4
commMACAddrThe physical address of the device receiving traps from the agent.ro
OCTET STRING
.1.3.6.1.4.1.485.2.2.1.5
commAccessAccess code assiciated with the community name of the same entry. noAccess indicates a community name with zero privileges. ro has read-only access to MIB objects. rw allows you to read and write MIB objects. SU (super- user) gives you privileges to read and write any MIB object. The community table itself can only be written to with an access of SU as well as the setting of the IP Address on a device.rw
Enumeration
.1.3.6.1.4.1.485.2.2.1.6
srNodeGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3
nodeUnitGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.1
unitControlGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.1.1
unitRestartSetting this variable to a value of 1 will force the unit to restart. Setting this variable to any other value will cause an SNMP error. This variable always returns a value of 2.rw
Enumeration
.1.3.6.1.4.1.485.3.1.1.1
dumpOnRestartSetting this variable to a value of 1 will force the unit to perform a dump on restart. Setting this variable to a value of 2 will force it to not to dump on restart.rw
Enumeration
.1.3.6.1.4.1.485.3.1.1.2
initiateInstallSetting this variable to a value of 1 will force the unit to initiate an install process. This variable always returns a value of 2.rw
Enumeration
.1.3.6.1.4.1.485.3.1.1.3
initializeStatsSetting this variable to a value of 1 will force the unit to initialize (clear) all statistics kept by the unit. This variable always returns a value of 2.rw
Enumeration
.1.3.6.1.4.1.485.3.1.1.4
clearDumpSetting this variable to a value of 1 will force the unit to clear a dump. This variable always returns a value of 2.rw
Enumeration
.1.3.6.1.4.1.485.3.1.1.5
unitStatusGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.1.2
unitModelThis variable defines the base hardware model of the unit: A boundary platform is the 486 single board unit. A LIC is the Central Site chassis card.ro
Enumeration
.1.3.6.1.4.1.485.3.1.2.1
softwareVersionThe current version number of the operating software in xx.yyy where xx = major release, yyy = revision.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.2
productTypeThe product type string returned is set in the MS.SYS file and defines the product.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.3
maxPortNumberThe maximum number of ports this unit can support (total number of serial access ports plus total number of LAN ports).ro
INTEGER
.1.3.6.1.4.1.485.3.1.2.4
maxPUThe maximum number of PUs this unit can support (total number that can be configured).ro
INTEGER
.1.3.6.1.4.1.485.3.1.2.5
maxSessionThe maximum number of sessions this unit can support (total number that can be configured).ro
INTEGER
.1.3.6.1.4.1.485.3.1.2.6
maxDeviceThe maximum number of devices this unit can support (total number that can be configured).ro
INTEGER
.1.3.6.1.4.1.485.3.1.2.7
msBoardTypeIndicates the type of serial I/O ports on main board. It returns 1 if not expected.ro
Enumeration
.1.3.6.1.4.1.485.3.1.2.8
msExtBoardTypeIndicates the type of serial I/O ports on extension board. It returns 1 if not present.ro
Enumeration
.1.3.6.1.4.1.485.3.1.2.9
dumpFileStatusIndicates the presence of a dump file.ro
Enumeration
.1.3.6.1.4.1.485.3.1.2.10
dumpFileNameThe dump file name.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.11
unitSerialNumberThe base unit serial number.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.12
expansionSerialNumberThe expansion board serial number.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.13
romVersionThe ROM version number.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.14
processorTypeThe base unit processor type.ro
Enumeration
.1.3.6.1.4.1.485.3.1.2.15
chassisSlotIf the unit is a blade in a chassis, then this variable indicates the slot number. If not applicable, a value of 99 will be returned.ro
INTEGER
.1.3.6.1.4.1.485.3.1.2.16
lastTrapSeqNumberThis entry contains the last sequence number of the last trap generated by the unit. When this value reaches its maximum, it then rolls back to 0.ro
INTEGER
.1.3.6.1.4.1.485.3.1.2.17
lastInstallErrCodeThis entry contains the status of last install. If the last install was successful, 0 is returned, 9999 indicates installation is in progress, otherwise an error code is returned.ro
INTEGER
.1.3.6.1.4.1.485.3.1.2.18
unitPartNumberThe base unit part number.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.19
expansionPartNumberThe expansion board part number.ro
DisplayString
.1.3.6.1.4.1.485.3.1.2.20
unitConfigGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.1.3
unitIdThis is the unit id. It consists of a 1 to 8 octet right justified case-sensitive ASCII field which uniquely identifies the unit. This ID is displayed on the LCD display, all system dumps, and any ASCII alarms. The defalult value for this field is startup.ro
DisplayString
.1.3.6.1.4.1.485.3.1.3.1
nmsSerialSpeedThe async serial port speed for NMS console port. The speed is expressed in bits per second (i.e. 9.6 Kbps is represented as 96 decimal). Currently supported speeds are: 1200 2400 4800 9600 19200 Default speed is 9600 bits per second.ro
Enumeration
.1.3.6.1.4.1.485.3.1.3.2
serialPortLogoffTimerUnits are minutes. Default value is 0, indicating that no timer is active.ro
INTEGER
.1.3.6.1.4.1.485.3.1.3.3
callRetryTimerThe call retry timer (a.k.a Session Retry Timer). The number of seconds to wait before trying to retry a failed LLC connection attempt. Currently supported values are 2 - 999 seconds. The default is 30 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.1.3.4
passwordThe unit's password. This field indicates the system password used to log into the unit for operating the NMS interface. This field is a one to eight byte case-sensitive left justified ASCII data field and may not be left blank. The default value is 'sri' (for Sync Research Inc.).rw
DisplayString
.1.3.6.1.4.1.485.3.1.3.5
configPasswordThe configuration password. This field indicates the password used to enter the configuration subsystem. This field is a one to eight byte case-sensitive left justified ASCII data field and may not be left blank. The default value is 'sri' (for Sync Research Inc.).rw
DisplayString
.1.3.6.1.4.1.485.3.1.3.6
dateTimeFieldThe date and time. This field is stored as 6 bytes of BCD Data in the following order: Month: 0x01 - 0x12 Day: 0x01 - 0x31 Year: 0x00 - 0x99 Hour: 0x00 - 0x23 Minute: 0x00 - 0x59 Second: 0x00 - 0x59rw
OCTET STRING
.1.3.6.1.4.1.485.3.1.3.7
configIdThe configuration identifer. This field is the configuration ID assigned when a new configuration is activated for the first time. It is assigned by the unit automatically and is not user assignable.ro
DisplayString
.1.3.6.1.4.1.485.3.1.3.8
internalMacAddressEmbedded conversion node MAC address. Applicable to Frame Node only.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.485.3.1.3.9
internalRingNumberEmbedded conversion node ring number. This should be unique within the network. Applicable to Frame Node only.ro
INTEGER
.1.3.6.1.4.1.485.3.1.3.10
internalBridgeNumberEmbedded conversion node bridge number. This parameter is currently not used. Applicable to Frame Node only.ro
INTEGER
.1.3.6.1.4.1.485.3.1.3.11
unitStatisticsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.1.4
numberSamplesThe number of internal system level samples performed. Samples are taken every 10th of a second.ro
Counter
.1.3.6.1.4.1.485.3.1.4.1
systemBufferFreeCountsThe average number of system buffers free in the system during the system sample period. The number of available buffers varies by system type and configuration. To determine the maximum number of buffers for a given configuration, view a sample when there is no activity in the unit. A heavily loaded unit will display a small number of available buffers and low Processor Idle counts.ro
INTEGER
.1.3.6.1.4.1.485.3.1.4.2
cpuIdleSumCountsThe main processor average idle sum count. This is the average number of times the idle counter was incremented over the sampling period divided by 1000. This is an absolute value of performance as does not vary by performance. A heavily loaded unit will display a small number of available buffers and low Processor Idle counts.ro
Counter
.1.3.6.1.4.1.485.3.1.4.3
nodeNetViewPUGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.2
netViewPUStatusGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.2.1
netviewConnectionStatusThe status of the Primary Netview Connectionro
Enumeration
.1.3.6.1.4.1.485.3.2.1.1
netviewLastClearCodeA two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed primary NetView connection attempt (a.k.a. call attempt) or Netview active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See current product documentation for list of possible values.ro
OCTET STRING
.1.3.6.1.4.1.485.3.2.1.2
netviewAltConnectionStatusThe status of the alternate Netview Connectionro
Enumeration
.1.3.6.1.4.1.485.3.2.1.3
netviewAltLastClearCodeA two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed alternate NetView connection attempt (a.k.a. call attempt) or Netview active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See current product documentation for list of possible values.ro
OCTET STRING
.1.3.6.1.4.1.485.3.2.1.4
netviewConnectionAttemptCountThe number of connection attempts performed on the Primary NetView PU. This count is set to zero at startup, and after every loss of an estabished session.ro
Counter
.1.3.6.1.4.1.485.3.2.1.5
netviewAltConnectionAttemptCountThe number of connection attempts performed on the Alternate NetView PU. This count is set to zero at startup, and after every loss of an estabished session.ro
Counter
.1.3.6.1.4.1.485.3.2.1.6
netViewPUConfigGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.2.2
netviewPUXIDPrimary NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadecimal data field. This field should be set to all zeroes if no Netview session is to be established. The default value is all zeroes.ro
OCTET STRING
.1.3.6.1.4.1.485.3.2.2.1
alternateNetviewPUXIDAlternate NetView PU XID. This field indicates the XID data to be sent to the host for establishing Netview Session. This field is a maximum four byte hexadecimal data field. This field should be set to all zeroes if no Netview session is to be established. The default value is all zeroes.ro
OCTET STRING
.1.3.6.1.4.1.485.3.2.2.2
netviewConnectIDThe primary NetView PU connection ID. The default value is 0.ro
OCTET STRING
.1.3.6.1.4.1.485.3.2.2.3
alternateNetviewConnectIDThe alternate NetView PU connection ID. The default value is 0.ro
OCTET STRING
.1.3.6.1.4.1.485.3.2.2.4
netviewSpecialConnectThe primary NetView PU connection type. The default value is originate.ro
Enumeration
.1.3.6.1.4.1.485.3.2.2.5
alternateNetviewSpecialConnectThe alternate NetView PU connection type. The default value is originate.ro
Enumeration
.1.3.6.1.4.1.485.3.2.2.6
nodeBridgeGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.3
bridgeConfigGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.3.1
brEnableBridgingThis flag indicates if bridging is to be performed on this unit. The default value for this field is 'No'ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.1
bridgePrioritySometimes referred to as the ROOT id. Determines the priority component of the Bridge identifier used in determining the Root Bridge for a spanning tree network.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.2
brMaxAgeThe time at which a configuration message is descarded. Units are in seconds. Default value is 10 secondsro
INTEGER
.1.3.6.1.4.1.485.3.3.1.3
brHelloTimerThe time interval between issuing configuration messages. Units are seconds. Default value is 2 secondsro
INTEGER
.1.3.6.1.4.1.485.3.3.1.4
brFilterIPXIf set to yes, all IPX frames are filtered (if bridge is enabled). Default is Yes.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.5
brFilterIPIf set to yes, all IP frames are filtered (if bridging is enabled). Default is Yes.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.6
brFilterNetBIOSIf set to yes, all NetBIOS frames are filtered (if bridging is enabled). Default is Yes.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.7
brFilterLLC2If set to yes, all LAN attached SNA LLC2 frames are filtered (if bridging is enabled). Default is Yes.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.8
brFilterSMANIf set to yes, all SyncManager LLC2 frames are filtered (if bridging is enabled). Default is Yes.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.9
brForwardOtherIf set to yes, all other frames are forwarded (if bridging is enabled). Default is No.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.10
brIPXtargetPortIf IPX filtering is set to no, then this parameter defines a specific FR port to deliver IPX frames to. Used in conjunction with brIPXtargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the IPX target port/DLCI is not configured. This field has the default value of 0.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.11
brIPXtargetDLCIIf IPX filtering is set to no, then this parameter defines a specific FR DLCI to deliver IPX frames to. Used in conjunction with brIPXtargetPort. If the value of brIPXtargetport is 0, then the value of brIPXtargetDLCI is not significant.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.12
brIPtargetPortIf IP filtering is set to no, then this parameter defines a specific FR port to deliver IP frames to. Used in conjunction with brIPtargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the IP target port/DLCI is not configured. This field has the default value of 0.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.13
brIPtargetDLCIIf IP filtering is set to no, then this parameter defines a specific FR DLCI to deliver IP frames to. Used in conjunction with brIPtargetPort. If the value of brIPtargetport is 0, then the value of brIPtargetDLCI is not significant.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.14
brNetBIOStargetPortIf NetBIOS filtering is set to no, then this parameter defines a specific FR port to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetDLCI. The valid range is 0 to 5. A value of 0 indicates that the NetBIOS target port/DLCI is not configured. This field has the default value of 0.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.15
brNetBIOStargetDLCIIf NetBIOS filtering is set to no, then this parameter defines a specific FR DLCI to deliver NetBIOS frames to. Used in conjunction with brNetBIOStargetPort. If the value of brNetBIOStargetport is 0, then the value of brNetBIOStargetDLCI is not significant.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.16
brLLC2targetPortIf SNA LLC2 filtering is set to no, then this parameter defines a specific FR port to deliver LLC2 frames to. Used in conjunction with brLLC2targetDLCI. The valid range is 0 to 5. A value of 0 indicates that the brLLC2targetport/brLLC2targetDLCI is not configured. This field has the default value of 0.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.17
brLLC2targetDLCIIf SNA LLC2 filtering is set to no, then this parameter defines a specific FR DLCI to deliver LLC2 frames to. Used in conjunction with brLLC2targetPort. If the value of brLLC2targetport is 0, then the value of brLLC2targetDLCI is not significant.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.18
brOthertargetPortIf Other forwarding is set to yes, then this parameter defines a specific FR port to deliver Other frames to. Used in conjunction with brOthertargetDLCI. The valid range is 0 to 5. The value 0 indicates that the brOthertargetport/brOthertargetDLCI is not configured. This field has the default value of 0.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.19
brOthertargetDLCIIf Other forwarding is set to yes, then this parameter defines a specific FR DLCI to deliver Other frames to. Used in conjunction with brOthertargetPort. If the value of brOthertargetport is 0, then the value of brOthertargetDLCI is not significant.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.20
brSerialPriorityThis parameter defines the transmit priority for Frame Relay of serial attached port traffic.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.21
brTerminatedLLC2PriorityThis parameter defines the transmit priority for Frame Relay of terminated LLC2 traffic.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.22
brLLC2PriorityThis parameter defines the transmit priority for Frame Relay of SNA LLC2 traffic.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.23
brIPXPriorityThis parameter defines the transmit priority for Frame Relay of IPX traffic.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.24
brIPPriorityThis parameter defines the transmit priority for Frame Relay of IP traffic.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.25
brNetBIOSPriorityThis parameter defines the transmit priority for Frame Relay of NetBIOS traffic.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.26
brOtherPriorityThis parameter defines the transmit priority for Frame Relay of other traffic.ro
Enumeration
.1.3.6.1.4.1.485.3.3.1.27
brHighPriorityBandwidthThis parameter defines the high priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 40.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.28
brMediumPriorityBandwidthThis parameter defines the medium priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 30.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.29
brLowPriorityBandwidthThis parameter defines the low priority bandwidth. The sum of high, medium, and low priority bandwidth cannot exceed 100. Default value is 20.ro
INTEGER
.1.3.6.1.4.1.485.3.3.1.30
nodeLANGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.4
lanControlGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.4.1
lanControlTableA table for controlling LAN ports and obtaining information.
SEQUENCE OF LanControlEntry
.1.3.6.1.4.1.485.3.4.1.1
lanControlEntryAn entry consisting of port information for a particular LAN port.
LanControlEntry
.1.3.6.1.4.1.485.3.4.1.1.1
lanControlIndexThe number that uniquely identifies this LAN port. Currently only one LAN port per unit is supported.ro
INTEGER
.1.3.6.1.4.1.485.3.4.1.1.1.1
lanControlTypeThe LAN type. Token-Ring ports run the IEEE 802.5 protocol. Ethernet-type run the IEEE 802.3 and Ethernet Version 2. Other LAN protocols may be added in the future.ro
Enumeration
.1.3.6.1.4.1.485.3.4.1.1.1.2
lanStatusThe status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the LAN. An enable all command will perform the same function as enable, since there are no sub elements on a LAN. A disable command will disable the LAN. Status: Enable(d) indicates the LAN is enabled and running. Disable(d) indicates the LAN has been disabled. Failed indicates the LAN is enabled and not Running.rw
Enumeration
.1.3.6.1.4.1.485.3.4.1.1.1.3
lanControlFailureCodeThis entry contains the failure codes if the associated LAN interface is in the failed state.ro
OCTET STRING
.1.3.6.1.4.1.485.3.4.1.1.1.4
lanControlNAUNameThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.4.1.1.1.5
lanTokenRingGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.4.2
lanPortTableA table of LAN information.
SEQUENCE OF LanPortEntry
.1.3.6.1.4.1.485.3.4.2.1
lanPortEntryAn entry consisting of port information for a particular LAN port.
LanPortEntry
.1.3.6.1.4.1.485.3.4.2.1.1
lanPortIndexThe port number that uniquely identifies this port. Currently only one LANtoken ring port per unit is supported with the port index = 1.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.1
lanPortTypeThe LAN port type.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.2
lanMACAddressThe user configured LANtoken ring MAC address. If the address is set to 0 then the burned-in Address is used. This field contains a user configured address if any. If a user configured address is desired, then it must be configured as a valid individual, user defined - MAC address. The address must be configured in the native format convention used by the LAN port. For token Ring LAN ports the address follows User configured addresses must follow IEEE 802.5 IEEE 802.5 rules (most significant bit transmitted first) and must be between 400000000000 and 7FFFFFFFFFFF hexadecimal inclusive. For Ethernet LAN ports the format is must follow IEEE 802.3 rules.where the two least significant bits of the first octet must be zero. This means the first octet must be in the set of numbers 0x00, 0x04, 0x08, ... 0xFC..... The Default Value for this field is all zeroes.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.485.3.4.2.1.1.3
lanPROMMACAddressThe burned in MAC address. This is the MAC address assigned by the factory when the unit is shipped. If the User configured address is set to 0, then this will be the address used by the adapter for the source address field for all frames sent by the LAN adapter. The format ordering of bits is as defined in IEEE 802.5. This ordering is where the Most Significant Bit is transmitted first. This is different from other protocols (e.g. 802.3) where the least significant bit is transmitted first. The representation of the MAC address is in the format native for the LAN port. Boundary platform Token-Ring LAN ports start with the first six digits (three octects) equal to 0002F6 which indicates a Sync Research Token Ring MAC address. Boundary platform Ethernet LAN ports start with the first six digits (three octects) equal to to 00406F which indicates a Sync Research Ethernet MAC address. This field is not changable via any commands and will always contain the manufactured MAC address for the LAN port.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.485.3.4.2.1.1.4
lanSpeedThe LAN port speed in Megabits/second. For Token-Ring boundary platforms, the speed is changable via the front panel keypad and LCD menus, and NMS console port. For Token-Ring LIC the speed is changed by a jumper on the back of the board (top two pins = 4, bottom two pins = 16). For Ethernet boundary platforms and LIC, the speed is not configurable.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.5
lanT1TimerThe default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for this field is 3 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.6
lanT2TimerThe default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received. Current supported values are 0 and 2-50. T2 should be less than T1. The default value for this field is 0 (disabled).ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.7
lanTiTimerThe default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for this field is 30 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.8
lanRxWindowSizeThe default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frames received before an RR frame is sent (defined as N3 in IEEE 802.2 LLC). Current allowable values are 1-7. The default value for this field is 7.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.9
lanTxWindowSizeThe defalut LLC transmit window size. Current allowable values are 1-7. The default value for this field is 7.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.10
lanMaxRetriesThe default LLC maximum number of retries (N2 value). Current allowable values are 1-99. The default value for this field is 3.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.11
lanRingNumber802.5 bridging parameter. This variable returns a value of 0, if it is not defined. This value is not applicable to Ethernet.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.12
lanBridgeNumber802.5 bridging parameter. The default value for this field is 1. This value is not applicable to Ethernet.ro
INTEGER
.1.3.6.1.4.1.485.3.4.2.1.1.13
lanEthernetFrameFormatThe Ethernet frame format used on this LAN. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.14
lanSendLocalTestThis port's send local test option. Identifies whether a test frame should be sent on the local ring to discover a destination MAC address. If all destinations for the unit are located on a remote ring, setting this field to No allows the unit to bypass discovery of a destination MAC address on the local ring. If this field is set to 'No' then the broadcastType field must be set to all routes or single route broadcast. If the any destination is on a local ring or unknown, this parameter should be set to 'Yes'. The default value for this field is 'Yes'. Not used if Ethernet, and 1 is returned.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.15
lanBroadcastTypeThis port's broadcast type. Not used if Ethernet. Types are: none, all-routes, and single-route. Identifies the form of a broadcast test frame sent to discover the route to a destination MAC address. If all destinations are located on the local ring, this field may be set to 'None' to prevent a broadcast search for a destination MAC address. If set to 'None', then the sendLocalTest field must be set to 'Yes'. If set as 'All-routes', the unit will send an All-routes broadcast TEST command frame and expect a non-broadcast TEST response frame in return. If set to Single-route, the unit will send a Single-route broadcast TEST command frame and expect a all-routes TEST response frame in return. The default for this field is all routes broadcast. Not used if Ethernet, and 1 is returned.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.16
lanIPAddressThis is the IP Address of this interface.ro
IpAddress
.1.3.6.1.4.1.485.3.4.2.1.1.17
lanNetworkMaskThis is the network mask to be used on this interface.ro
IpAddress
.1.3.6.1.4.1.485.3.4.2.1.1.18
lanDefaultGatewayDefault gateway address to be used when sending responses on this interface.ro
IpAddress
.1.3.6.1.4.1.485.3.4.2.1.1.19
lanNAUNameThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.4.2.1.1.20
lanInterfaceTypeThis port's physical interface type. Only used if Ethernet. The default for this field is utp. Not used if Token Ring, and 1 is returned.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.21
lanIPEthernetFrameTypeThe IP Ethernet frame format used on this LAN for IP frames. The default value for this field is 802.3. Not used if Token Ring, and 1 is returned.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.22
lanInitStateThe initial state of the LAN port. If configured for 'in-service', then the LAN port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the LAN port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'.ro
Enumeration
.1.3.6.1.4.1.485.3.4.2.1.1.23
nodeLineGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.5
lineControlGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.5.1
lineControlTableA table for controlling lines and obtaining information.
SEQUENCE OF LineControlEntry
.1.3.6.1.4.1.485.3.5.1.1
lineControlEntryAn entry consisting of port information for a particular port.
LineControlEntry
.1.3.6.1.4.1.485.3.5.1.1.1
lineControlIndexThe port number that uniquely identifies this port.ro
INTEGER
.1.3.6.1.4.1.485.3.5.1.1.1.1
lineControlTypeThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream CUs (e.g. 3274 or ATM Bisync controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host or upstream CU. Frame Relay ports support Frame Relay PVC. Future line types (e.g. X.25) may be added here.ro
Enumeration
.1.3.6.1.4.1.485.3.5.1.1.1.2
lineStatusThe status of the port. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the line. An enable all command will attempt to bring up the line and any lower layer entities (e.g. PUs). A disable command will disable the line. Status: Enable(d) indicates the line is enabled and running. Disable(d) indicates the line has been disabled. Failed indicates the line is enabled and not Running.rw
Enumeration
.1.3.6.1.4.1.485.3.5.1.1.1.3
lineControlFailureCodeThis entry contains the failure codes if the associated port interface is in the failed state.ro
OCTET STRING
.1.3.6.1.4.1.485.3.5.1.1.1.4
lineControlNAUNameThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.5.1.1.1.5
linePhysicalGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.5.2
linePhysicalTableA table for obtaining physical signal status information.
SEQUENCE OF LinePhysicalEntry
.1.3.6.1.4.1.485.3.5.2.1
linePhysicalEntryAn entry consisting of port information for a particular port.
LinePhysicalEntry
.1.3.6.1.4.1.485.3.5.2.1.1
linePhysicalIndexThe port number that uniquely identifies this port.ro
INTEGER
.1.3.6.1.4.1.485.3.5.2.1.1.1
linePhysicalTypeThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream CUs (e.g. 3274 or ATM Bisync controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host or upstream CU. Frame Relay ports support Frame Relay PVC.ro
Enumeration
.1.3.6.1.4.1.485.3.5.2.1.1.2
lineEIAStatusA port's current control signal status. All SDLC ports have the ability to read the current status of RS-232 or equivalent control signals. The value returned is a 16 bit value where each bit signifies a signal status where 1 means the signal is active and 0 means the signal is inactive. The value returned is a snapshot taken when the command actually is sent to the driver software and wherever possible actually goes out to the driver or receiver control chips to get the value. Currently defined bit values are as follows*: 128 : Data Terminal Ready 0x0080 RS-232 pin 20 64 : Data Set Ready 0x0040 RS-232 pin 6 32 : Clear to Send 0x0020 RS-232 pin 5 16 : Clear to Send Ext. 0x0010 RS-232 pin 11** 8 : Data Carrier Detect 0x0008 RS-232 pin 8 4 : Busy Out 0x0004 RS-232 pin 25 2 : Request to send 0x0002 RS-232 pin 4 1 : Ring Indicator 0x0001 RS-232 pin 22 Note*: Bit values higher than 128 are reserved for future use. Note**: Clear to Send External is extended (non- standard) pin and reserved for future use by Sync Research.ro
INTEGER
.1.3.6.1.4.1.485.3.5.2.1.1.3
lineQualityFrameCountThis entry contains the number of frames received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. When this value reaches its maximum, it then rolls back to 0. Applicable to SDLC only.ro
Counter
.1.3.6.1.4.1.485.3.5.2.1.1.4
lineQualityCRCErrorsThis entry contains the number of frames with CRC errors. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. Applicable to SDLC only.ro
Counter
.1.3.6.1.4.1.485.3.5.2.1.1.5
lineQualityAbortsThis entry contains the number of aborts received. For every 255 incoming frames, a trap is generated by the unit if lineQualityCRCErrors or lineQualityAborts exceeds 5. Applicable to SDLC only.ro
Counter
.1.3.6.1.4.1.485.3.5.2.1.1.6
lineSDLCGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.5.3
sdlcConfigTableA table of SDLC information.
SEQUENCE OF SdlcConfigEntry
.1.3.6.1.4.1.485.3.5.3.1
sdlcConfigEntryAn entry consisting of port information for a particular SDLC port.
SdlcConfigEntry
.1.3.6.1.4.1.485.3.5.3.1.1
sdlcConfigPortIndexThe port number that uniquely identifies this port. Current supported SDLC numbers are 1-4.ro
INTEGER
.1.3.6.1.4.1.485.3.5.3.1.1.1
sdlcConfigTypeThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU. Note that all ports must currently be defined as the same time for a given unit (i.e. no mixing of HSDLC and TSDLC ports is allowed).ro
Enumeration
.1.3.6.1.4.1.485.3.5.3.1.1.2
sdlcInitStateThe initial state of the SDLC port. If configured for 'in-service', then the SDLC port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.3.1.1.3
sdlcCarrierThis field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. RTS, RS-232 pin 4) is constant or switched. This parameter also affects SDLC flag generation. If configured for constant then the line will transmit flags in an idle (no data being sent) state. If configured for switched then the line will transmit all one bits (mark state). The default value for this parameter is 'constant'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.3.1.1.4
sdlcClockingClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.3.1.1.5
sdlcSpeedThe ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 ports units (must be V.35 or RS-422).ro
INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640), -- speed128000(1280) -- }
.1.3.6.1.4.1.485.3.5.3.1.1.6
sdlcPauseThis parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the PUs as fast as possible. The minimum value for this parameter is 5 and the timer has a resolution of 25 milliseconds. The default value is 20 (.20 seconds). This field is not applicable to Host port. It returns a dummy value.ro
INTEGER
.1.3.6.1.4.1.485.3.5.3.1.1.7
sdlcNRZIThis parameter indicates whether the port is configured for NRZI (yes) or NRZ (no) bit encoding. The default value is 'No' (NRZ encoding selected).ro
Enumeration
.1.3.6.1.4.1.485.3.5.3.1.1.8
sdlcT1TimerThe SDLC T1 timer value in 20ths of a second. The default value is 20 (5 seconds). This field is not applicable to Host ports. It returns a dummy value.ro
INTEGER
.1.3.6.1.4.1.485.3.5.3.1.1.9
sdlcSlowPollTimerThe slow poll timer value in 20ths of a second. The slow poll timer is the amount of time to wait to contact (send SNRM) failed PUs. The default value for this field is 600 (30 seconds). This field is not applicable to Host ports. It returns a dummy value.ro
INTEGER
.1.3.6.1.4.1.485.3.5.3.1.1.10
sdlcMaxRetriesThe maximum number of retries (N2 value) before failing a PU. The default value for this field is 3. This field is not applicable to Host ports. It returns a dummy value.ro
INTEGER
.1.3.6.1.4.1.485.3.5.3.1.1.11
sdlcNAUNameThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.5.3.1.1.12
sdlcMultiFlagInsertionThis parameter indicates whether the port is configured to send multiple interframe flags. The default value is 'No' (single flags).ro
Enumeration
.1.3.6.1.4.1.485.3.5.3.1.1.13
sdlcStatsTableA table of SDLC information.
SEQUENCE OF SdlcStatsEntry
.1.3.6.1.4.1.485.3.5.3.2
sdlcStatsEntryAn entry consisting of port information for a particular SDLC port.
SdlcStatsEntry
.1.3.6.1.4.1.485.3.5.3.2.1
sdlcStatsPortIndexThe port number that uniquely identifies this SDLC port. Current supported numbers on are 1-4.ro
INTEGER
.1.3.6.1.4.1.485.3.5.3.2.1.1
sdlcPortTypeThe port type. TSDLC (Terminal SDLC) ports emulate a Host and poll the downstream PUs (e.g. 3274 or 3174 SDLC/SNA controllers). HSDLC ports (Host SDLC) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU.ro
Enumeration
.1.3.6.1.4.1.485.3.5.3.2.1.2
sdlcInOctetsThe number of bytes received.ro
Counter
.1.3.6.1.4.1.485.3.5.3.2.1.3
sdlcOutOctetsThe number of bytes sent.ro
Counter
.1.3.6.1.4.1.485.3.5.3.2.1.4
sdlcInFramesThe number of I-frames received.ro
Counter
.1.3.6.1.4.1.485.3.5.3.2.1.5
sdlcOutFramesThe number of I-frames sent.ro
Counter
.1.3.6.1.4.1.485.3.5.3.2.1.6
sdlcOverrunsThe number of overruns.ro
Counter
.1.3.6.1.4.1.485.3.5.3.2.1.7
sdlcCRCErrorsThe number of CRC errors.ro
Counter
.1.3.6.1.4.1.485.3.5.3.2.1.8
sdlcRecvAbortsThe number of aborts received.ro
Counter
.1.3.6.1.4.1.485.3.5.3.2.1.9
lineBisyncGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.5.4
bisyncConfigTableA table of Bisync port information.
SEQUENCE OF BisyncConfigEntry
.1.3.6.1.4.1.485.3.5.4.1
bisyncConfigEntryAn entry consisting of port information for a particular Bisync port.
BisyncConfigEntry
.1.3.6.1.4.1.485.3.5.4.1.1
bisyncConfigPortIndexThe port number that uniquely identifies this port. Current supported Bisync numbers are 1-4.ro
INTEGER
.1.3.6.1.4.1.485.3.5.4.1.1.1
bisyncConfigTypeThe port type. TBSC (Terminal Bisync) ports emulate a Host and polls the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (CUs) and respond to polls from the Host.ro
Enumeration
.1.3.6.1.4.1.485.3.5.4.1.1.2
bisyncNAUNameThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.5.4.1.1.3
bisyncInitStateThe initial state of the Bisync port. If configured for 'in-service', then the Bisync port will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', then the Bisync port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.4.1.1.4
bisyncCarrierThis field indicates whether Carrier (a.k.a. CD or DCD, RS-232 pin 8) is constant or switched for DCE devices (internally clocked), or Request To Send (a.k.a. RTS, RS-232 pin 4) is constant or switched. The default value for this parameter is 'constant'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.4.1.1.5
bisyncClockingClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.4.1.1.6
bisyncSpeedThe ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 64000 are not supported.ro
INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640) -- }
.1.3.6.1.4.1.485.3.5.4.1.1.7
bisyncPauseThis parameter defines the amount of time between polls in 1/100 second (10 millisecond) intervals. If set to zero then the port will poll the CUs as fast as possible. The minimum value for this parameter is 5 and the timer has a resolution of 25 milliseconds. The default value is 20 (.20 seconds). This field is not applicable to a Host port. It returns a dummy value.ro
INTEGER
.1.3.6.1.4.1.485.3.5.4.1.1.8
bisyncReplyTimerThe time to wait for a response in seconds. The default value for this field is 3 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.5.4.1.1.9
bisyncRetriesThe maximum number of retries (N2 value) before failing a CU. The default value for this field is 5.ro
INTEGER
.1.3.6.1.4.1.485.3.5.4.1.1.10
bisyncSlowpollTimerThe time to wait in seconds before attempting a slowpoll. The default value for this field is 30 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.5.4.1.1.11
bisyncSessTermThe type of session termination used. Only applies to Host BSC ports.ro
Enumeration
.1.3.6.1.4.1.485.3.5.4.1.1.12
bisyncStatsTableA table of Bisync information.
SEQUENCE OF BisyncStatsEntry
.1.3.6.1.4.1.485.3.5.4.2
bisyncStatsEntryAn entry consisting of port information for a particular Bisync port.
BisyncStatsEntry
.1.3.6.1.4.1.485.3.5.4.2.1
bisyncStatsPortIndexThe port number that uniquely identifies this Bisync port. Current supported numbers are 1-4.ro
INTEGER
.1.3.6.1.4.1.485.3.5.4.2.1.1
bisyncPortTypeThe port type. TBSC (Terminal Bisync) ports emulate a Host and poll the downstream controllers). HBSC ports (Host Bisync) ports emulate a line with Terminal Controllers (PUs) and respond to polls from the Host or upstream PU.ro
Enumeration
.1.3.6.1.4.1.485.3.5.4.2.1.2
bisyncInOctetsThe number of bytes received.ro
Counter
.1.3.6.1.4.1.485.3.5.4.2.1.3
bisyncOutOctetsThe number of bytes sent.ro
Counter
.1.3.6.1.4.1.485.3.5.4.2.1.4
bisyncOverrunsThe number of receiver overruns.ro
Counter
.1.3.6.1.4.1.485.3.5.4.2.1.5
bisyncCRCErrorsThe number of receive frame CRC errors.ro
Counter
.1.3.6.1.4.1.485.3.5.4.2.1.6
bisyncRcvTimeoutThe number of receive timeout.ro
Counter
.1.3.6.1.4.1.485.3.5.4.2.1.7
bisyncXmtTimeoutThe number of transmit timeout.ro
Counter
.1.3.6.1.4.1.485.3.5.4.2.1.8
lineFrameRelayGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.5.5
frameRelayConfigTableA table of Sync product Frame Relay information.
SEQUENCE OF FrameRelayConfigEntry
.1.3.6.1.4.1.485.3.5.5.1
frameRelayConfigEntryAn entry consisting of port information for a particular Sync product Frame Relay port.
FrameRelayConfigEntry
.1.3.6.1.4.1.485.3.5.5.1.1
frameRelayConfigPortIndexThe port number that uniquely identifies this port.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.1
frameRelayPortTypeThe Frame Relay port type.ro
Enumeration
.1.3.6.1.4.1.485.3.5.5.1.1.2
frameRelayInitStateThe initial state of the Frame Relay port. If configured for 'in-service', then the Frame Relay port will be brougt up automatically when the unit is powered up. If configured for 'out-of-service', then the Frame Relay port must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'enabled'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.5.1.1.3
frameRelayClockingClocking source for this port. Setting 'internal' will cause the port to emulate a physical DCE, and setting external will cause the port to emulate a physical DTE. X21 External and Internal are used (with the proper external adapter) to support X.21 Leased Line operation for RS-422/RS-530 (25 pin balanced) interfaces. X21 operation is not supported for boards that operate RS-232 or V.35. The default value for this field is 'external'.ro
Enumeration
.1.3.6.1.4.1.485.3.5.5.1.1.4
frameRelaySpeedThe ports speed in bits per second. The default value is 9600 bits per second. Speeds higher than 19200 are not supported on RS-232 port Sync products (must be V.35 or RS-422).ro
INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640), -- speed128000(1280), -- speed256000(2560) -- }
.1.3.6.1.4.1.485.3.5.5.1.1.5
frameRelayLocalManagementProtocolThe ports management protocol type. Annex D = ANSI T1.617 Annex D LMI = Frame Relay Manufacturers LMI The default value is Annex D.ro
Enumeration
.1.3.6.1.4.1.485.3.5.5.1.1.6
frameRelayLinkPollingTimerMeasured in seconds, intervals of 5 T391 - Annex D nT1 - LMI The default value for this field is 5 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.7
frameRelayFullStatusPollingCountThe number of polls that a full status poll is issued. N391 - Annex D nT1 - LMI The default value for this field is 6.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.8
frameRelayT1TimerThe default LLC T1 timer value in seconds. T1 should be greater than T2 and less than Ti. Currently supported values are 1 to 25 seconds. The default value for this field is 3 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.9
frameRelayT2TimerThe default LLC T2 timer value in tenths of seconds. If configured for 0 then the T2 timer is disabled and an RR frame will be sent for every I frame received. Current supported values are 0 and 2-50. T2 should be less than T1. The default value for this field is 0 (disabled).ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.10
frameRelayTiTimerThe default LLC Ti (inactivity) timer value in seconds. Ti should be greater than T1. Currently supported values are 2 to 50 seconds. The default value for this field is 30 seconds.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.11
frameRelayRxWindowSizeThe default LLC receive window (N3) size. Note that this is not the same receive window as defined in IEEE 802.2 LLC. This is N3 which is the number of I frames received before an RR frame is sent (defined as N3 in IEEE 802.2 LLC). Current allowable values are 1-7. The default value for this field is 7.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.12
frameRelayTxWindowSizeThe defalut LLC transmit window size. Current allowable values are 1-7. The default value for this field is 7.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.13
frameRelayMaxRetriesThe default LLC maximum number of retries (N2 value). The default value for this field is 15.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.14
frameRelayNAUNameThe NAU name of this port. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.5.5.1.1.15
frameRelayVirtualMACAddressThe F/R WAN is treated as a token ring. This address is used for communication with other bridges in the network.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.485.3.5.5.1.1.16
frameRelayVirtualRingNumberThe F/R WAN is treated as a token ring. This is the ring number for the F/R network to which the port is attached. It must be a unique ring number in the network. The default value for this field is 1.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.17
frameRelayVirtualBridgeNumberThe F/R WAN is treated as a token ring. This variable only has significance if more than 1 F/R port is configured. The default value for this field is 1.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.1.1.18
frameRelayIPAddressThis is the IP Address of this interface.ro
IpAddress
.1.3.6.1.4.1.485.3.5.5.1.1.19
frameRelayNetworkMaskThis is the network mask to be used on this interface.ro
IpAddress
.1.3.6.1.4.1.485.3.5.5.1.1.20
frameRelayDefaultGatewayAddressDefault gateway address to be used when sending responses on this interface.ro
IpAddress
.1.3.6.1.4.1.485.3.5.5.1.1.21
frameRelayStatsTableA table of Frame Relay information.
SEQUENCE OF FrameRelayStatsEntry
.1.3.6.1.4.1.485.3.5.5.2
frameRelayStatsEntryAn entry consisting of port information for a particular Frame Relay port.
FrameRelayStatsEntry
.1.3.6.1.4.1.485.3.5.5.2.1
frameRelayStatsPortIndexThe port number that uniquely identifies this Frame Relay port.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.2.1.1
frameRelayInOctetsThe number of bytes received inclusive of all valid bytes in the frame relay frame except for the CRC field (frame relay header included).ro
Counter
.1.3.6.1.4.1.485.3.5.5.2.1.2
frameRelayOutOctetsThe number of bytes transmitted inclusive of all bytes in the frame relay frame except for the CRC field (frame relay header included).ro
Counter
.1.3.6.1.4.1.485.3.5.5.2.1.3
frameRelaySampleDurationThe sample duration in seconds for Frame Relay Statistics for this port.ro
INTEGER
.1.3.6.1.4.1.485.3.5.5.2.1.4
frameRelayOverrunsThe number of receiver overruns.ro
Counter
.1.3.6.1.4.1.485.3.5.5.2.1.5
frameRelayCRCErrorsThe number of received CRC errors.ro
Counter
.1.3.6.1.4.1.485.3.5.5.2.1.6
frameRelayRecvAbortsThe number of received frame aborts received.ro
Counter
.1.3.6.1.4.1.485.3.5.5.2.1.7
nodePUGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.6
puControlGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.6.1
puControlTableA table for controlling lines and obtaining information.
SEQUENCE OF PuControlEntry
.1.3.6.1.4.1.485.3.6.1.1
puControlEntryAn entry consisting of PU information for a particular port.
PuControlEntry
.1.3.6.1.4.1.485.3.6.1.1.1
puControlLineIndexThe port number that has a given PU.ro
INTEGER
.1.3.6.1.4.1.485.3.6.1.1.1.1
puControlPUAddressThe PU address in the range of 0x01 to 0xfe.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.1.1.1.2
puStatusThe status of the PU. To change status of a port an enable, enable all or disable may be set. Valid Return status are enable(d), disable(d), or failed. Commands: An enable command will attempt to bring up the PU. An enable all command will attempt to bring up the line and any lower layer entities (e.g. PUs). A disable command will disable the PU. Status: Enable(d) indicates the PU is enabled and running. Disable(d) indicates the PU has been disabled. Failed indicates the PU is enabled and not Running.rw
Enumeration
.1.3.6.1.4.1.485.3.6.1.1.1.3
puConnectionStatusThe status of the LLC type 2 Connection for this SDLC PU.ro
Enumeration
.1.3.6.1.4.1.485.3.6.1.1.1.4
puLastClearCodeA two octet field indicating the Last Clearing Cause and Diagnostic Field of the last failed connection attempt (a.k.a. call attempt) or active connection (a.k.a. session). For LLC type 2 connections the first octet (cause) is always 0. The second octet (diagnostic) indicates the reason for the last connection failure. The second octet is set to 0 when a sucessful call has been placed, or if no call has ever been placed (e.g. PU never came up). If the second octet is non-zero then it indicates the reason for the connection attempt failure. See User's Guide for informationro
OCTET STRING
.1.3.6.1.4.1.485.3.6.1.1.1.5
puControlFailureCodeThis entry contains the failure codes if the associated PU is in the failed state.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.1.1.1.6
puControlNAUNameThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.6.1.1.1.7
puConnectionAttemptCountThe number of connection attempts performed. This count is set to zero at startup, and after every loss of an estabished session.ro
Counter
.1.3.6.1.4.1.485.3.6.1.1.1.8
puSDLCGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.6.2
sdlcPuConfigTableA list of PU entries.
SEQUENCE OF SdlcPuConfigEntry
.1.3.6.1.4.1.485.3.6.2.1
sdlcPuConfigEntryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
SdlcPuConfigEntry
.1.3.6.1.4.1.485.3.6.2.1.1
sdlcPuConfigLineIndexThe port number for which the line (CU)is configured (first level).ro
INTEGER
.1.3.6.1.4.1.485.3.6.2.1.1.1
sdlcPuConfigAddressThe PU address in the range of 0x00 to 0xfe.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.2.1.1.2
sdlcPuNAUNameThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.6.2.1.1.3
sdlcPuInitialStateThe initial state of the PU. If configured for 'in-service', then the SDLC PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'.ro
Enumeration
.1.3.6.1.4.1.485.3.6.2.1.1.4
sdlcPuXIDThe XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. If the field is configured to 0 then the unit will solicit the XID from the downstream PU and send the XID data received from SDLC to the XID data sent for the LLC connection process. If not sent to 0, then the unit will insert the data configured in the LLC sent to the host during the LLC connection process on behalf of the CU. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The default value for this field is all zeroes (solicit XID from PU).ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.2.1.1.5
sdlcPuTypeThe SNA PU type. 1 = PU type 1 2 = PU type 2 3 = PU type 2.1 4 = PU type 4 (not supported, reserved) 5 = PU type 5 (not supported, reserved) This parameter defaults to a value of 2.ro
Enumeration
.1.3.6.1.4.1.485.3.6.2.1.1.6
sdlcPuGroupPollAddressThe PU's group address in the range of 0x01 to 0xfe. setting this value to 0 will disable the group poll feature for polling this and other PUs in a group. The default value for this field is 0.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.2.1.1.7
sdlcPuConnectionIDThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.2.1.1.8
sdlcPuMAXOUTThis entry defines the maximum number of outstanding I frames that the PU will allow. This field is applicable to TSDLC only.ro
INTEGER
.1.3.6.1.4.1.485.3.6.2.1.1.9
sdlcPuConnectTypeThe SNA PU Connection type.ro
Enumeration
.1.3.6.1.4.1.485.3.6.2.1.1.10
sdlcPuStatsTableA list of PU statistics entries.
SEQUENCE OF SdlcPuStatsEntry
.1.3.6.1.4.1.485.3.6.2.2
sdlcPuStatsEntryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
SdlcPuStatsEntry
.1.3.6.1.4.1.485.3.6.2.2.1
sdlcPuStatsLineIndexThe port number for which PU is configured on.ro
INTEGER
.1.3.6.1.4.1.485.3.6.2.2.1.1
sdlcPuStatsAddressThe PU address in the range of 0x00 to 0xfe.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.2.2.1.2
sdlcPuInIFramesThe number of I frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.3
sdlcPuOutIFramesThe number of I frames trasnmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.4
sdlcPuInRRFramesThe number of RR frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.5
sdlcPuOutRRFramesThe number of RR frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.6
sdlcPuInRNRFramesThe number of RNR frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.7
sdlcPuOutRNRFramesThe number of RNR frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.8
sdlcPuInXIDFramesThe number of XID frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.9
sdlcPuOutXIDFramesThe number of XID frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.10
sdlcPuInTESTFramesThe number of TEST frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.11
sdlcPuOutTESTFramesThe number of TEST frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.12
sdlcPuInSNRMFramesThe number of SNRM frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.13
sdlcPuOutSNRMFramesThe number of SNRM frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.14
sdlcPuInDISCFramesThe number of DISC frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.15
sdlcPuOutDISCFramesThe number of DISC frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.16
sdlcPuInDMFramesThe number of DM frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.17
sdlcPuOutDMFramesThe number of DM frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.18
sdlcPuInUAFramesThe number of UA frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.19
sdlcPuOutUAFramesThe number of UA frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.20
sdlcPuInFRMRFramesThe number of FRMR frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.21
sdlcPuOutFRMRFramesThe number of FRMR frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.22
sdlcPuInRDFramesThe number of RD frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.23
sdlcPuOutRDFramesThe number of RD frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.24
sdlcPuInUIFramesThe number of UI frames received on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.25
sdlcPuOutUIFramesThe number of UI frames transmitted on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.26
sdlcPuReTxIFramesThe number of re-transmitted I frames on this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.27
sdlcPuPollResponseTimeoutsThe number of PU Poll Response timeouts for this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.2.2.1.28
puBisyncGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.6.3
bisyncPuConfigTableA list of Bisync CU entries.
SEQUENCE OF BisyncPuConfigEntry
.1.3.6.1.4.1.485.3.6.3.1
bisyncPuConfigEntryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
BisyncPuConfigEntry
.1.3.6.1.4.1.485.3.6.3.1.1
bisyncPuConfigLineIndexThe port number for which PU is configured on.ro
INTEGER
.1.3.6.1.4.1.485.3.6.3.1.1.1
bisyncPuConfigAddressThe PU address in the range of 0x00 to 0xfe.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.3.1.1.2
bisyncPuNAUNameThe NAU name of this PU. The default value for this field is all blank (filled with ASCII space 0x20 characters).ro
DisplayString
.1.3.6.1.4.1.485.3.6.3.1.1.3
bisyncPuInitialStateThe initial state of the PU. If configured for 'in-service', then the SDLC PU will be brougt up automattically when the unit is powered up. If configured for 'out-of-service', the the SDLC PU must be manually enabled by operator intervention (i.e. enable command must be sent). The default value is 'in-service'.ro
Enumeration
.1.3.6.1.4.1.485.3.6.3.1.1.4
bisyncPuXIDThe XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. The unit will insert the data configured in the LLC XID sent to the host during the LLC connection process on behalf of the CU. For bisync control units, this field is required as bisync cannot solicit an XID. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The default value for this field is all zeroes.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.3.1.1.5
bisyncPuTargetHostTypeThe Target Host type. 1 = SNA host type 2 = Bisync host type This field specifies the target host type for TBSC and is applicable to BSC-to-SNA conversion only. This parameter defaults to a value of 2.ro
Enumeration
.1.3.6.1.4.1.485.3.6.3.1.1.6
bisyncPuMaxDataThis entry defines the SNA frame size which is the sum of SNA data and SNA header. This value must match the MAXData configured for SNA host and is applicable to BSC-to-SNA conversion only. The default value is 521. The valid range is 265, 521, 777, 1033, 1289.ro
INTEGER
.1.3.6.1.4.1.485.3.6.3.1.1.7
bisyncPuConnectionIDThis entry defines the Connection ID to a corresponding entry in the mapping table. The default value for this field is all zeroes.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.3.1.1.8
bisyncPuConnectTypeThe Bisync PU Connection type.ro
Enumeration
.1.3.6.1.4.1.485.3.6.3.1.1.9
bisyncPuStatsTableA list of PU statistics entries.
SEQUENCE OF BisyncPuStatsEntry
.1.3.6.1.4.1.485.3.6.3.2
bisyncPuStatsEntryThis entry contains information about a given PU. The entry is indexed by the port number and the PU number.
BisyncPuStatsEntry
.1.3.6.1.4.1.485.3.6.3.2.1
bisyncPuStatsLineIndexThe port number for which PU is configured on.ro
INTEGER
.1.3.6.1.4.1.485.3.6.3.2.1.1
bisyncPuStatsAddressThe PU address in the range of 0x00 to 0xfe.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.3.2.1.2
bisyncPuInTransactionsThe number of PU Poll Response timeouts for this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.3.2.1.3
bisyncPuOutTransactionsThe number of PU Poll Response timeouts for this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.3.2.1.4
bisyncPuSlowPollsThe number of PU slow polls for this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.3.2.1.5
bisyncPuPollsThe number of PU Polls for this PU.ro
Counter
.1.3.6.1.4.1.485.3.6.3.2.1.6
puMappingGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.6.4
mappingPuConfigTableA list of PU mapping entries.
SEQUENCE OF MappingPuConfigEntry
.1.3.6.1.4.1.485.3.6.4.1
mappingPuConfigEntryThis entry contains information about a given mapping PU. Each entry includes MAC/SAP information for a source PU and a similar information for the partner (mapped) PU. Depending upon whether the PU is LAN-attached, SDLC-attached or Frame Relay-attached, one or more fields may not apply. Some fields, for example, mappingPuNAU, mappingPuXID, mappingPuConnectID are common to both end points. The entry is indexed by the port number and the PU number.
MappingPuConfigEntry
.1.3.6.1.4.1.485.3.6.4.1.1
mappingPuConfigLineIndexThe port number for which PU is associated with. Port number 99 is a special value which is used to indicate NetView PU.ro
INTEGER
.1.3.6.1.4.1.485.3.6.4.1.1.1
mappingPuConfigAddressThe PU address in the range of 0x01 to 0xfe.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.2
mappingPuSourceSAPThe LLC source SAP value for this PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.3
mappingPuDestinationSAPThe LLC Destination SAP value for this PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. If not it returns a dummy value. This parameter defaults to a value of 4.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.4
mappingPuDestinationMACThe LAN Destination MAC address used in the LLC Type 2 connection for this PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.485.3.6.4.1.1.5
mappingPuPartnerConfigLineIndexThe port number for the partner PU associated with source PU. Port number 99 is a special value which is used to indicate NetView PU.ro
INTEGER
.1.3.6.1.4.1.485.3.6.4.1.1.6
mappingPuPartnerConfigAddressThe PU address of the partner PU in the range of 0x01 to 0xfe.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.7
mappingPuPartnerSourceSAPThe LLC source SAP value for a partner PU. Typically the source SAP will vary for each PU. This is due to the fact that most Sync products are configured to always call the same remote Token-Ring Host or Gateway for all connections configured. This means that all the Destination SAP (usually set to 4) and Destination MAC addresses are the same, so the Source SAP field must be set to a unique value in order to uniquely identify the LLC connection to the Host. (SNA does not allow multiplexing of PUs on one LLC connection. Each PU must have its own LLC Type 2 connection.) This field must be set to a range between 04 and E8 hexadecimal and it must be evenly divisible by 4 (802.2 LLC rules for user assigned SAPs). This field is not applicable in all cases, if not it returns a dummy value. This parameter defaults to a value of 4.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.8
mappingPuPartnerDestSAPThe LLC Destination SAP value for the partner PU. For SNA typically the destination is almost always SAP 4. However both Host Front Ends (e.g. 3745) or Gateways (e.g. 3174) allow SAPs to be configured for any value betwee 0x04 and 0xEC as long as the SAP ID is a user assignable individual SAP ID (any value evenly divisable by 4). This field is not applicable to all cases. It returns a dummy value. This parameter defaults to a value of 4.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.9
mappingPuPartnerDestMACThe LAN Destination MAC address used in the LLC Type 2 connection for the partner PU. The Token-Ring format for this field is a 6 octet (48 bit) field represented in IEEE 802.5 format where the first bit transmitted is the most significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses are between 000000000001 and 7FFFFFFFFFFF (an address of all zeroes is not supported). The Ethernet format for this field is a 6 octet (48 bit) field represented in IEEE 802.3 format where the first bit transmitted is the least significant bit. The destination MAC must also be an 'Individual' address. Therefore valid addresses must start with the least significant bit equal to 0. In other words, the first two digits must be in the set of 0x00, 0x02, 0x04, ... 0xFE (an address of all 12 digits equal to zeroes is not supported). This field is not applicable to all cases. If not it returns a dummy value.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.485.3.6.4.1.1.10
mappingPuNAUThe NAU Name. The NAU name is same for both the source PU and the partner PU. It represents one physical PU in a network.ro
DisplayString
.1.3.6.1.4.1.485.3.6.4.1.1.11
mappingPuConnectIDThe connection ID. This must match a connection ID of an access line PU or another mapping PU Connection ID. The connnection ID is 0 if there is no mapping.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.12
mappingPuXIDThe XID value for this PU. The XID is used to identify the PU during the LLC connection process to the remote Host or Gateway. For incoming LLC connections on Sync Research products this field is parsed to route the connection to the proper PU. The XID is same for both the source PU and the partner PU. It represents one physical PU in a network. The default value for this field is all zeroes.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.13
mappingPuDirectDLCIThe Frame Relay DLCI used in the LLC Type 2 connection for this PU. The Frame Relay format for this field is a 2 octet (16 bit) field represented in BCD format. A valid DLCI would be from 0001 to 1023 (0000 is reserved for AnnexD management. 1023 is reserved for LMI mangement.). This value is applicable to Frame Relay-attached PU only. The field corresponds to a source port or a partner port depending upon whether the source PU is a Frame Relay-attached PU or the partner PU is Frame Relay-attached PU. For Frame Relay-attached PU if this value is not configured, 0 is returned.ro
OCTET STRING
.1.3.6.1.4.1.485.3.6.4.1.1.14
nodeDeviceGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.7
deviceControlGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.7.1
deviceControlTableA table for controlling devices and obtaining information.
SEQUENCE OF DeviceControlEntry
.1.3.6.1.4.1.485.3.7.1.1
deviceControlEntryAn entry consisting of device information for a particular device.
DeviceControlEntry
.1.3.6.1.4.1.485.3.7.1.1.1
deviceControlIndexThe number that uniquely identifies this device.ro
INTEGER
.1.3.6.1.4.1.485.3.7.1.1.1.1
deviceControlCUIndexThe CU index for this device.ro
INTEGER
.1.3.6.1.4.1.485.3.7.1.1.1.2
deviceControlAddressThe device address.ro
OCTET STRING
.1.3.6.1.4.1.485.3.7.1.1.1.3
deviceStatusThe status of the device. To change (write) status of a device, enable, disable, restart or enable all may be set. Valid Return (read) status are enable(d), disable(d), or failed (d). Commands: An enable command will attempt to bring up the device. An enable all command will perform the same function as enable, since there are no sub elements on a device. A disable command will disable the device. Status: Enable(d) indicates the device is enabled and running. Disable(d) indicates the device has been disabled. Failed (d) indicates the device is enabled and not Running.rw
Enumeration
.1.3.6.1.4.1.485.3.7.1.1.1.4
deviceControlFailureCodeThis entry contains the failure codes if the associated device is in the failed state.ro
OCTET STRING
.1.3.6.1.4.1.485.3.7.1.1.1.5
deviceBSCGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.485.3.7.2
deviceConfigTableA list of device entries.
SEQUENCE OF DeviceConfigEntry
.1.3.6.1.4.1.485.3.7.2.1
deviceConfigEntryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
DeviceConfigEntry
.1.3.6.1.4.1.485.3.7.2.1.1
deviceConfigLineIndexThe port number for which the line (CU)is configured (line level).ro
INTEGER
.1.3.6.1.4.1.485.3.7.2.1.1.1
deviceConfigCUIndexThe CU index which this device is configured on (CU level).ro
INTEGER
.1.3.6.1.4.1.485.3.7.2.1.1.2
deviceConfigAddressThe device address in the legal range of BSC poll addresses (device level).ro
OCTET STRING
.1.3.6.1.4.1.485.3.7.2.1.1.3
deviceConfigTypeThe device type. The default value is crt.ro
Enumeration
.1.3.6.1.4.1.485.3.7.2.1.1.4
deviceStatsTableA table of device statistics information.
SEQUENCE OF DeviceStatsEntry
.1.3.6.1.4.1.485.3.7.2.2
deviceStatsEntryThis entry contains information about a given device. The entry is indexed by the port number, CU index, and device.
DeviceStatsEntry
.1.3.6.1.4.1.485.3.7.2.2.1
bscDeviceLineIndexThe port number for which the line (CU)is configured (line level).ro
INTEGER
.1.3.6.1.4.1.485.3.7.2.2.1.1
bscDeviceCUIndexThe CU index which this device is configured on (CU level).ro
INTEGER
.1.3.6.1.4.1.485.3.7.2.2.1.2
bscDeviceAddressThe device address in the legal range of BSC poll addresses (device level).ro
OCTET STRING
.1.3.6.1.4.1.485.3.7.2.2.1.3
bscDeviceInTransactionsThe number of device receiving transactions.ro
Counter
.1.3.6.1.4.1.485.3.7.2.2.1.4
bscDeviceOutTransactionsThe number of device transmitting transactions.ro
Counter
.1.3.6.1.4.1.485.3.7.2.2.1.5
bscDeviceSumCountThe device sum count.ro
Counter
.1.3.6.1.4.1.485.3.7.2.2.1.6
bscDeviceResponseDelaySumThe device sum count.ro
Counter
.1.3.6.1.4.1.485.3.7.2.2.1.7
bscDeviceResponseDelaySqSumThe device sum count.ro
Counter
.1.3.6.1.4.1.485.3.7.2.2.1.8
SYNC-RESEARCH-MIB - SNMP MIB Reference | MIBs Explorer