SYNC-RESEARCH-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for SYNC-RESEARCH-MIB.
398
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
398 total| Object Name |
|---|
syncResearch OBJECT IDENTIFIER .1.3.6.1.4.1.485 |
RFC1155-SMI Unknown .1.3.6.1.4.1.485 |
configChangedThis trap indicates that the configuration of
the unit has been changed. TRAP-TYPE .1.3.6.1.4.1.485.0.800 |
configErrorThis trap indicates that the activation of configuration
of the unit has resulted in an error. New configuration
has not been successfully activated. TRAP-TYPE .1.3.6.1.4.1.485.0.801 |
dumpExistsThis trap indicates that a memory core dump exists. TRAP-TYPE .1.3.6.1.4.1.485.0.802 |
dumpArchivedThis trap indicates that the memory dump file has been
archived. TRAP-TYPE .1.3.6.1.4.1.485.0.803 |
lineStatusChangedThis trap indicates that the indicated Line or Port has
changed state. It has either been enabled, failed or
disabled. TRAP-TYPE .1.3.6.1.4.1.485.0.804 |
lanStatusChangedThis trap indicates that the indicated LAN Port has
changed state. It has either been enabled, failed or
disabled. TRAP-TYPE .1.3.6.1.4.1.485.0.805 |
lineQuality TRAP-TYPE .1.3.6.1.4.1.485.0.806 |
puStatusChangedThis trap indicates that the indicated PU has
changed state. It has either been enabled, failed or
disabled. TRAP-TYPE .1.3.6.1.4.1.485.0.807 |
puConnectionStatusChangedNote this trap is obsolete. This trap indicates that the indicated PU has
changed connection state. Its connection has either been
established, disconnected, or rejected. TRAP-TYPE .1.3.6.1.4.1.485.0.808 |
netviewConnectionStatusChangedNote this trap is obsolete. This trap indicates that the NetView PU has
changed connection state. Its connection has either been
established, disconnected, or rejected. TRAP-TYPE .1.3.6.1.4.1.485.0.809 |
netviewAltConnectionStatusChangedNote this trap is obsolete. This trap indicates that the Alternate NetView PU has
changed connection state. Its connection has either been
established, disconnected, or rejected. TRAP-TYPE .1.3.6.1.4.1.485.0.810 |
puConnectionStatusUpThis trap indicates that the indicated PU has
changed connection state. Its connection had been established. TRAP-TYPE .1.3.6.1.4.1.485.0.811 |
puConnectionStatusDownThis trap indicates that the indicated PU has
changed connection state. Its connection has been disconnected.
If the indicated PU is not in session, the trap is generated only
if the clear code is different from the puLastClearCode. TRAP-TYPE .1.3.6.1.4.1.485.0.812 |
netviewConnectionStatusUpThis trap indicates that the indicated NetView PU has
changed connection state. Its connection has been established. TRAP-TYPE .1.3.6.1.4.1.485.0.813 |
netviewConnectionStatusDownThis trap indicates that the indicated NetView PU has
changed connection state. Its connection had been disconnected.
If the indicated PU is not in session, the trap is generated only
if the clear code is different from the netviewLastClearCode. TRAP-TYPE .1.3.6.1.4.1.485.0.814 |
netviewAltConnectionStatusUpThis trap indicates that the indicated Alternate
NetView PU has changed connection state. Its connection has been
established. TRAP-TYPE .1.3.6.1.4.1.485.0.815 |
netviewAltConnectionStatusDownThis trap indicates that the indicated Alternate
NetView PU has changed connection state. Its connection had been
disconnected. If the indicated PU is not in session, the trap is generated
only if the clear code is different from the netviewAltLastClearCode. TRAP-TYPE .1.3.6.1.4.1.485.0.816 |
syncResearchAgent OBJECT IDENTIFIER .1.3.6.1.4.1.485.1 |
syncProducts OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1 |
boundary OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.1 |
syncCN2R2b OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.1.1 |
syncFN2R2b OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.1.2 |
syncCN4R2b OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.1.3 |
syncFN4R2b OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.1.4 |
syncQN4R2b OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.1.5 |
centralSite OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.2 |
syncCN4R2c OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.2.1 |
syncFN4R2c OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.2.2 |
syncQN4R2c OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.1.2.3 |
oemProducts OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2 |
threeCom OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.1 |
linkConverter OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.1.1 |
cableTron OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.2 |
oemSNACXR2C OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.2.1 |
oemSNACXR2W OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.2.2 |
oemSNACMR2C OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.2.3 |
oemSNACMR2W OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.2.4 |
chipcom OBJECT IDENTIFIER .1.3.6.1.4.1.485.1.2.3 |
srCommTrapGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.2 |
commCountThe number of possible community name entries
in the table.ro INTEGER .1.3.6.1.4.1.485.2.1 |
commTableThis table houses the information for trivial
authentication and sending traps. SEQUENCE OF CommEntry .1.3.6.1.4.1.485.2.2 |
commEntryEach entry contains a community name and access code
for SNMP trivial authenticationm an enable/disable traps
options, as well as network and physical addressing
information for traps. CommEntry .1.3.6.1.4.1.485.2.2.1 |
commIndexA unique value for each community entry. Its value
ranges between 1 and commCount.ro INTEGER .1.3.6.1.4.1.485.2.2.1.1 |
commNameA community name that will be used to access MIB
objects within the device. Each community name is
associated with an access code of either NO_ACCESS, RO,
RW, or SU.rw OCTET STRING .1.3.6.1.4.1.485.2.2.1.2 |
commTrapThis object is checked to determine if traps should be
sent to the corresponding network address associated
with it.rw Enumeration .1.3.6.1.4.1.485.2.2.1.3 |
commIPAddrThe network address of the device that will receive
traps from the agent. This IP address also qualifies
who may use this community name to access MIB objects.
If this community name is use by some one with a
different IP address, an Authentication Trap will
be generated. If the IP address is set to 0.0.0.0,
anyone may use this address, however, traps will
not be sent since the address is invalid.rw IpAddress .1.3.6.1.4.1.485.2.2.1.4 |
commMACAddrThe physical address of the device receiving traps
from the agent.ro OCTET STRING .1.3.6.1.4.1.485.2.2.1.5 |
commAccessAccess code assiciated with the community name of the
same entry. noAccess indicates a community name with
zero privileges. ro has read-only access to MIB objects.
rw allows you to read and write MIB objects. SU (super-
user) gives you privileges to read and write any MIB
object. The community table itself can only be written
to with an access of SU as well as the setting of the
IP Address on a device.rw Enumeration .1.3.6.1.4.1.485.2.2.1.6 |
srNodeGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3 |
nodeUnitGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.1 |
unitControlGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.1.1 |
unitRestartSetting this variable to a value of 1 will
force the unit to restart. Setting this variable
to any other value will cause an SNMP error.
This variable always returns a value of 2.rw Enumeration .1.3.6.1.4.1.485.3.1.1.1 |
dumpOnRestartSetting this variable to a value of 1 will
force the unit to perform a dump on restart. Setting
this variable to a value of 2 will force it to not
to dump on restart.rw Enumeration .1.3.6.1.4.1.485.3.1.1.2 |
initiateInstallSetting this variable to a value of 1 will force
the unit to initiate an install process. This variable
always returns a value of 2.rw Enumeration .1.3.6.1.4.1.485.3.1.1.3 |
initializeStatsSetting this variable to a value of 1 will force
the unit to initialize (clear) all statistics kept
by the unit.
This variable always returns a value of 2.rw Enumeration .1.3.6.1.4.1.485.3.1.1.4 |
clearDumpSetting this variable to a value of 1 will
force the unit to clear a dump.
This variable always returns a value of 2.rw Enumeration .1.3.6.1.4.1.485.3.1.1.5 |
unitStatusGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.1.2 |
unitModelThis variable defines the base hardware model of
the unit:
A boundary platform is the 486 single board unit.
A LIC is the Central Site chassis card.ro Enumeration .1.3.6.1.4.1.485.3.1.2.1 |
softwareVersionThe current version number of the operating
software in xx.yyy where xx = major release,
yyy = revision.ro DisplayString .1.3.6.1.4.1.485.3.1.2.2 |
productTypeThe product type string returned is set in the
MS.SYS file and defines the product.ro DisplayString .1.3.6.1.4.1.485.3.1.2.3 |
maxPortNumberThe maximum number of ports this unit can
support (total number of serial access ports plus
total number of LAN ports).ro INTEGER .1.3.6.1.4.1.485.3.1.2.4 |
maxPUThe maximum number of PUs this unit can
support (total number that can be configured).ro INTEGER .1.3.6.1.4.1.485.3.1.2.5 |
maxSessionThe maximum number of sessions this unit can
support (total number that can be configured).ro INTEGER .1.3.6.1.4.1.485.3.1.2.6 |
maxDeviceThe maximum number of devices this unit can
support (total number that can be configured).ro INTEGER .1.3.6.1.4.1.485.3.1.2.7 |
msBoardTypeIndicates the type of serial I/O ports on
main board. It returns 1 if not expected.ro Enumeration .1.3.6.1.4.1.485.3.1.2.8 |
msExtBoardTypeIndicates the type of serial I/O ports on
extension board. It returns 1 if not present.ro Enumeration .1.3.6.1.4.1.485.3.1.2.9 |
dumpFileStatusIndicates the presence of a dump file.ro Enumeration .1.3.6.1.4.1.485.3.1.2.10 |
dumpFileNameThe dump file name.ro DisplayString .1.3.6.1.4.1.485.3.1.2.11 |
unitSerialNumberThe base unit serial number.ro DisplayString .1.3.6.1.4.1.485.3.1.2.12 |
expansionSerialNumberThe expansion board serial number.ro DisplayString .1.3.6.1.4.1.485.3.1.2.13 |
romVersionThe ROM version number.ro DisplayString .1.3.6.1.4.1.485.3.1.2.14 |
processorTypeThe base unit processor type.ro Enumeration .1.3.6.1.4.1.485.3.1.2.15 |
chassisSlotIf the unit is a blade in a chassis, then
this variable indicates the slot number. If
not applicable, a value of 99 will be returned.ro INTEGER .1.3.6.1.4.1.485.3.1.2.16 |
lastTrapSeqNumberThis entry contains the last sequence number of the
last trap generated by the unit. When this value
reaches its maximum, it then rolls back to 0.ro INTEGER .1.3.6.1.4.1.485.3.1.2.17 |
lastInstallErrCodeThis entry contains the status of last install.
If the last install was successful, 0 is returned,
9999 indicates installation is in progress,
otherwise an error code is returned.ro INTEGER .1.3.6.1.4.1.485.3.1.2.18 |
unitPartNumberThe base unit part number.ro DisplayString .1.3.6.1.4.1.485.3.1.2.19 |
expansionPartNumberThe expansion board part number.ro DisplayString .1.3.6.1.4.1.485.3.1.2.20 |
unitConfigGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.1.3 |
unitIdThis is the unit id. It consists of a 1 to 8 octet
right justified case-sensitive ASCII field which
uniquely identifies the unit.
This ID is displayed on the LCD display, all system
dumps, and any ASCII alarms.
The defalult value for this field is startup.ro DisplayString .1.3.6.1.4.1.485.3.1.3.1 |
nmsSerialSpeedThe async serial port speed for NMS console port.
The speed is expressed in bits per second (i.e.
9.6 Kbps is represented as 96 decimal).
Currently supported speeds are:
1200
2400
4800
9600
19200
Default speed is 9600 bits per second.ro Enumeration .1.3.6.1.4.1.485.3.1.3.2 |
serialPortLogoffTimerUnits are minutes. Default value is 0, indicating
that no timer is active.ro INTEGER .1.3.6.1.4.1.485.3.1.3.3 |
callRetryTimerThe call retry timer (a.k.a Session Retry Timer).
The number of seconds to wait before trying
to retry a failed LLC connection attempt.
Currently supported values are 2 - 999 seconds.
The default is 30 seconds.ro INTEGER .1.3.6.1.4.1.485.3.1.3.4 |
passwordThe unit's password.
This field indicates the system password used to
log into the unit for operating the NMS interface.
This field is a one to eight byte case-sensitive
left justified ASCII data field and may not be
left blank.
The default value is 'sri' (for Sync Research Inc.).rw DisplayString .1.3.6.1.4.1.485.3.1.3.5 |
configPasswordThe configuration password.
This field indicates the password used to
enter the configuration subsystem.
This field is a one to eight byte case-sensitive
left justified ASCII data field and may not be
left blank.
The default value is 'sri' (for Sync Research Inc.).rw DisplayString .1.3.6.1.4.1.485.3.1.3.6 |
dateTimeFieldThe date and time.
This field is stored as 6 bytes of BCD Data in the
following order:
Month: 0x01 - 0x12
Day: 0x01 - 0x31
Year: 0x00 - 0x99
Hour: 0x00 - 0x23
Minute: 0x00 - 0x59
Second: 0x00 - 0x59rw OCTET STRING .1.3.6.1.4.1.485.3.1.3.7 |
configIdThe configuration identifer.
This field is the configuration ID assigned
when a new configuration is activated for the
first time. It is assigned by the unit
automatically and is not user assignable.ro DisplayString .1.3.6.1.4.1.485.3.1.3.8 |
internalMacAddressEmbedded conversion node MAC address. Applicable
to Frame Node only.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.485.3.1.3.9 |
internalRingNumberEmbedded conversion node ring number. This should
be unique within the network. Applicable
to Frame Node only.ro INTEGER .1.3.6.1.4.1.485.3.1.3.10 |
internalBridgeNumberEmbedded conversion node bridge number. This
parameter is currently not used. Applicable
to Frame Node only.ro INTEGER .1.3.6.1.4.1.485.3.1.3.11 |
unitStatisticsGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.1.4 |
numberSamplesThe number of internal system level samples
performed. Samples are taken every 10th of a
second.ro Counter .1.3.6.1.4.1.485.3.1.4.1 |
systemBufferFreeCountsThe average number of system buffers free in
the system during the system sample period.
The number of available buffers varies by
system type and configuration. To determine
the maximum number of buffers for a given
configuration, view a sample when there is no
activity in the unit.
A heavily loaded unit will display a small number
of available buffers and low Processor Idle counts.ro INTEGER .1.3.6.1.4.1.485.3.1.4.2 |
cpuIdleSumCountsThe main processor average idle sum count.
This is the average number of times the idle counter
was incremented over the sampling period divided
by 1000. This is an absolute value of performance
as does not vary by performance.
A heavily loaded unit will display a small number
of available buffers and low Processor Idle counts.ro Counter .1.3.6.1.4.1.485.3.1.4.3 |
nodeNetViewPUGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.2 |
netViewPUStatusGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.2.1 |
netviewConnectionStatusThe status of the Primary Netview Connectionro Enumeration .1.3.6.1.4.1.485.3.2.1.1 |
netviewLastClearCodeA two octet field indicating the Last Clearing
Cause and Diagnostic Field of the last failed primary
NetView connection attempt (a.k.a. call attempt) or
Netview active connection (a.k.a. session).
For LLC type 2 connections the first octet (cause)
is always 0. The second octet (diagnostic)
indicates the reason for the last connection failure.
The second octet is set to 0 when a sucessful
call has been placed, or if no call has ever been
placed (e.g. PU never came up).
If the second octet is non-zero then it indicates
the reason for the connection attempt failure.
See current product documentation for list of possible
values.ro OCTET STRING .1.3.6.1.4.1.485.3.2.1.2 |
netviewAltConnectionStatusThe status of the alternate Netview Connectionro Enumeration .1.3.6.1.4.1.485.3.2.1.3 |
netviewAltLastClearCodeA two octet field indicating the Last Clearing
Cause and Diagnostic Field of the last failed alternate
NetView connection attempt (a.k.a. call attempt) or
Netview active connection (a.k.a. session).
For LLC type 2 connections the first octet (cause)
is always 0. The second octet (diagnostic)
indicates the reason for the last connection failure.
The second octet is set to 0 when a sucessful
call has been placed, or if no call has ever been
placed (e.g. PU never came up).
If the second octet is non-zero then it indicates
the reason for the connection attempt failure.
See current product documentation for list of possible
values.ro OCTET STRING .1.3.6.1.4.1.485.3.2.1.4 |
netviewConnectionAttemptCountThe number of connection attempts performed on the
Primary NetView PU. This count is set to zero at
startup, and after every loss of an estabished
session.ro Counter .1.3.6.1.4.1.485.3.2.1.5 |
netviewAltConnectionAttemptCountThe number of connection attempts performed on the
Alternate NetView PU. This count is set to zero at
startup, and after every loss of an estabished
session.ro Counter .1.3.6.1.4.1.485.3.2.1.6 |
netViewPUConfigGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.2.2 |
netviewPUXIDPrimary NetView PU XID.
This field indicates the XID data to be
sent to the host for establishing Netview Session.
This field is a maximum four byte hexadecimal
data field.
This field should be set to all zeroes if no
Netview session is to be established.
The default value is all zeroes.ro OCTET STRING .1.3.6.1.4.1.485.3.2.2.1 |
alternateNetviewPUXIDAlternate NetView PU XID.
This field indicates the XID data to be
sent to the host for establishing Netview Session.
This field is a maximum four byte hexadecimal
data field.
This field should be set to all zeroes if no
Netview session is to be established.
The default value is all zeroes.ro OCTET STRING .1.3.6.1.4.1.485.3.2.2.2 |
netviewConnectIDThe primary NetView PU connection ID.
The default value is 0.ro OCTET STRING .1.3.6.1.4.1.485.3.2.2.3 |
alternateNetviewConnectIDThe alternate NetView PU connection ID.
The default value is 0.ro OCTET STRING .1.3.6.1.4.1.485.3.2.2.4 |
netviewSpecialConnectThe primary NetView PU connection type.
The default value is originate.ro Enumeration .1.3.6.1.4.1.485.3.2.2.5 |
alternateNetviewSpecialConnectThe alternate NetView PU connection type.
The default value is originate.ro Enumeration .1.3.6.1.4.1.485.3.2.2.6 |
nodeBridgeGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.3 |
bridgeConfigGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.3.1 |
brEnableBridgingThis flag indicates if bridging is to be performed
on this unit.
The default value for this field is 'No'ro Enumeration .1.3.6.1.4.1.485.3.3.1.1 |
bridgePrioritySometimes referred to as the ROOT id. Determines the
priority component of the Bridge identifier used in
determining the Root Bridge for a spanning tree network.ro INTEGER .1.3.6.1.4.1.485.3.3.1.2 |
brMaxAgeThe time at which a configuration message is descarded.
Units are in seconds. Default value is 10 secondsro INTEGER .1.3.6.1.4.1.485.3.3.1.3 |
brHelloTimerThe time interval between issuing configuration
messages. Units are seconds. Default value is 2 secondsro INTEGER .1.3.6.1.4.1.485.3.3.1.4 |
brFilterIPXIf set to yes, all IPX frames are filtered (if
bridge is enabled). Default is Yes.ro Enumeration .1.3.6.1.4.1.485.3.3.1.5 |
brFilterIPIf set to yes, all IP frames are filtered (if bridging
is enabled). Default is Yes.ro Enumeration .1.3.6.1.4.1.485.3.3.1.6 |
brFilterNetBIOSIf set to yes, all NetBIOS frames are filtered
(if bridging is enabled). Default is Yes.ro Enumeration .1.3.6.1.4.1.485.3.3.1.7 |
brFilterLLC2If set to yes, all LAN attached SNA LLC2 frames are
filtered (if bridging is enabled). Default is Yes.ro Enumeration .1.3.6.1.4.1.485.3.3.1.8 |
brFilterSMANIf set to yes, all SyncManager LLC2 frames are
filtered (if bridging is enabled). Default is Yes.ro Enumeration .1.3.6.1.4.1.485.3.3.1.9 |
brForwardOtherIf set to yes, all other frames are forwarded (if
bridging is enabled). Default is No.ro Enumeration .1.3.6.1.4.1.485.3.3.1.10 |
brIPXtargetPortIf IPX filtering is set to no, then this parameter
defines a specific FR port to deliver IPX frames to.
Used in conjunction with brIPXtargetDLCI.
The valid range is 0 to 5. A value of 0 indicates that
the IPX target port/DLCI is not configured.
This field has the default value of 0.ro INTEGER .1.3.6.1.4.1.485.3.3.1.11 |
brIPXtargetDLCIIf IPX filtering is set to no, then this parameter
defines a specific FR DLCI to deliver IPX frames to.
Used in conjunction with brIPXtargetPort.
If the value of brIPXtargetport is 0, then the value of
brIPXtargetDLCI is not significant.ro INTEGER .1.3.6.1.4.1.485.3.3.1.12 |
brIPtargetPortIf IP filtering is set to no, then this parameter
defines a specific FR port to deliver IP frames to.
Used in conjunction with brIPtargetDLCI.
The valid range is 0 to 5. A value of 0 indicates that
the IP target port/DLCI is not configured.
This field has the default value of 0.ro INTEGER .1.3.6.1.4.1.485.3.3.1.13 |
brIPtargetDLCIIf IP filtering is set to no, then this parameter
defines a specific FR DLCI to deliver IP frames to.
Used in conjunction with brIPtargetPort.
If the value of brIPtargetport is 0, then the value of
brIPtargetDLCI is not significant.ro INTEGER .1.3.6.1.4.1.485.3.3.1.14 |
brNetBIOStargetPortIf NetBIOS filtering is set to no, then this parameter
defines a specific FR port to deliver NetBIOS frames
to. Used in conjunction with brNetBIOStargetDLCI.
The valid range is 0 to 5. A value of 0 indicates that
the NetBIOS target port/DLCI is not configured.
This field has the default value of 0.ro INTEGER .1.3.6.1.4.1.485.3.3.1.15 |
brNetBIOStargetDLCIIf NetBIOS filtering is set to no, then this parameter
defines a specific FR DLCI to deliver NetBIOS frames
to. Used in conjunction with brNetBIOStargetPort.
If the value of brNetBIOStargetport is 0, then the
value of brNetBIOStargetDLCI is not significant.ro INTEGER .1.3.6.1.4.1.485.3.3.1.16 |
brLLC2targetPortIf SNA LLC2 filtering is set to no, then this parameter
defines a specific FR port to deliver LLC2 frames to.
Used in conjunction with brLLC2targetDLCI.
The valid range is 0 to 5. A value of 0 indicates that
the brLLC2targetport/brLLC2targetDLCI is not configured.
This field has the default value of 0.ro INTEGER .1.3.6.1.4.1.485.3.3.1.17 |
brLLC2targetDLCIIf SNA LLC2 filtering is set to no, then this parameter
defines a specific FR DLCI to deliver LLC2 frames to.
Used in conjunction with brLLC2targetPort.
If the value of brLLC2targetport is 0, then the value
of brLLC2targetDLCI is not significant.ro INTEGER .1.3.6.1.4.1.485.3.3.1.18 |
brOthertargetPortIf Other forwarding is set to yes, then this parameter
defines a specific FR port to deliver Other frames to.
Used in conjunction with brOthertargetDLCI.
The valid range is 0 to 5. The value 0 indicates that
the brOthertargetport/brOthertargetDLCI is not
configured.
This field has the default value of 0.ro INTEGER .1.3.6.1.4.1.485.3.3.1.19 |
brOthertargetDLCIIf Other forwarding is set to yes, then this parameter
defines a specific FR DLCI to deliver Other frames to.
Used in conjunction with brOthertargetPort.
If the value of brOthertargetport is 0, then the value
of brOthertargetDLCI is not significant.ro INTEGER .1.3.6.1.4.1.485.3.3.1.20 |
brSerialPriorityThis parameter defines the transmit priority for
Frame Relay of serial attached port traffic.ro Enumeration .1.3.6.1.4.1.485.3.3.1.21 |
brTerminatedLLC2PriorityThis parameter defines the transmit priority for
Frame Relay of terminated LLC2 traffic.ro Enumeration .1.3.6.1.4.1.485.3.3.1.22 |
brLLC2PriorityThis parameter defines the transmit priority for
Frame Relay of SNA LLC2 traffic.ro Enumeration .1.3.6.1.4.1.485.3.3.1.23 |
brIPXPriorityThis parameter defines the transmit priority for
Frame Relay of IPX traffic.ro Enumeration .1.3.6.1.4.1.485.3.3.1.24 |
brIPPriorityThis parameter defines the transmit priority for
Frame Relay of IP traffic.ro Enumeration .1.3.6.1.4.1.485.3.3.1.25 |
brNetBIOSPriorityThis parameter defines the transmit priority for
Frame Relay of NetBIOS traffic.ro Enumeration .1.3.6.1.4.1.485.3.3.1.26 |
brOtherPriorityThis parameter defines the transmit priority for
Frame Relay of other traffic.ro Enumeration .1.3.6.1.4.1.485.3.3.1.27 |
brHighPriorityBandwidthThis parameter defines the high priority bandwidth.
The sum of high, medium, and low priority bandwidth
cannot exceed 100.
Default value is 40.ro INTEGER .1.3.6.1.4.1.485.3.3.1.28 |
brMediumPriorityBandwidthThis parameter defines the medium priority bandwidth.
The sum of high, medium, and low priority bandwidth
cannot exceed 100.
Default value is 30.ro INTEGER .1.3.6.1.4.1.485.3.3.1.29 |
brLowPriorityBandwidthThis parameter defines the low priority bandwidth.
The sum of high, medium, and low priority bandwidth
cannot exceed 100.
Default value is 20.ro INTEGER .1.3.6.1.4.1.485.3.3.1.30 |
nodeLANGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.4 |
lanControlGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.4.1 |
lanControlTableA table for controlling LAN ports and obtaining
information. SEQUENCE OF LanControlEntry .1.3.6.1.4.1.485.3.4.1.1 |
lanControlEntryAn entry consisting of port information for a
particular LAN port. LanControlEntry .1.3.6.1.4.1.485.3.4.1.1.1 |
lanControlIndexThe number that uniquely identifies
this LAN port.
Currently only one LAN port per unit is supported.ro INTEGER .1.3.6.1.4.1.485.3.4.1.1.1.1 |
lanControlTypeThe LAN type.
Token-Ring ports run the IEEE 802.5 protocol.
Ethernet-type run the IEEE 802.3 and Ethernet
Version 2.
Other LAN protocols may be added in
the future.ro Enumeration .1.3.6.1.4.1.485.3.4.1.1.1.2 |
lanStatusThe status of the port.
To change status of a port an enable, enable all
or disable may be set.
Valid Return status are enable(d), disable(d),
or failed.
Commands:
An enable command will attempt to bring up the LAN.
An enable all command will perform the same function
as enable, since there are no sub elements on a LAN.
A disable command will disable the LAN.
Status:
Enable(d) indicates the LAN is enabled and running.
Disable(d) indicates the LAN has been disabled.
Failed indicates the LAN is enabled and not
Running.rw Enumeration .1.3.6.1.4.1.485.3.4.1.1.1.3 |
lanControlFailureCodeThis entry contains the failure codes if the
associated LAN interface is in the failed state.ro OCTET STRING .1.3.6.1.4.1.485.3.4.1.1.1.4 |
lanControlNAUNameThe NAU name of this port.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.4.1.1.1.5 |
lanTokenRingGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.4.2 |
lanPortTableA table of LAN information. SEQUENCE OF LanPortEntry .1.3.6.1.4.1.485.3.4.2.1 |
lanPortEntryAn entry consisting of port information for a
particular LAN port. LanPortEntry .1.3.6.1.4.1.485.3.4.2.1.1 |
lanPortIndexThe port number that uniquely identifies
this port.
Currently only one LANtoken ring port per unit is
supported with the port index = 1.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.1 |
lanPortTypeThe LAN port type.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.2 |
lanMACAddressThe user configured LANtoken ring MAC address.
If the address is set to 0 then the burned-in Address
is used. This field contains a user configured
address if any. If a user configured address
is desired, then it must be configured as
a valid individual, user defined - MAC address.
The address must be configured in the native
format convention used by the LAN port.
For token Ring LAN ports the address follows
User configured addresses must follow IEEE 802.5
IEEE 802.5 rules (most significant bit transmitted first)
and must be between 400000000000 and 7FFFFFFFFFFF
hexadecimal inclusive.
For Ethernet LAN ports the format is must
follow IEEE 802.3 rules.where the two least
significant bits of the first octet must be
zero. This means the first octet must be
in the set of numbers 0x00, 0x04, 0x08, ...
0xFC.....
The Default Value for this field is all zeroes.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.485.3.4.2.1.1.3 |
lanPROMMACAddressThe burned in MAC address.
This is the MAC address assigned by the factory
when the unit is shipped. If the User configured
address is set to 0, then this will be the address
used by the adapter for the source address field
for all frames sent by the LAN adapter.
The format ordering of bits is as defined in
IEEE 802.5. This ordering is where the Most
Significant Bit is transmitted first. This is
different from other protocols (e.g. 802.3) where
the least significant bit is transmitted first.
The representation of the MAC address is
in the format native for the LAN port.
Boundary platform Token-Ring LAN ports start with the
first six digits (three octects) equal to
0002F6 which indicates a Sync Research Token Ring
MAC address.
Boundary platform Ethernet LAN ports start with
the first six digits (three octects) equal to
to 00406F which indicates a Sync Research
Ethernet MAC address.
This field is not changable via any commands
and will always contain the manufactured
MAC address for the LAN port.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.485.3.4.2.1.1.4 |
lanSpeedThe LAN port speed in Megabits/second.
For Token-Ring boundary platforms, the speed is
changable via the front panel keypad and LCD menus,
and NMS console port.
For Token-Ring LIC the speed is changed
by a jumper on the back of the board (top
two pins = 4, bottom two pins = 16).
For Ethernet boundary platforms and LIC, the speed is
not configurable.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.5 |
lanT1TimerThe default LLC T1 timer value in seconds.
T1 should be greater than T2 and less than Ti.
Currently supported values are 1 to 25 seconds.
The default value for this field is 3 seconds.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.6 |
lanT2TimerThe default LLC T2 timer value in tenths of seconds.
If configured for 0 then the T2 timer is disabled
and an RR frame will be sent for every I frame
received.
Current supported values are 0 and 2-50.
T2 should be less than T1.
The default value for this field is 0 (disabled).ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.7 |
lanTiTimerThe default LLC Ti (inactivity) timer value
in seconds.
Ti should be greater than T1.
Currently supported values are 2 to 50 seconds.
The default value for this field is 30 seconds.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.8 |
lanRxWindowSizeThe default LLC receive window (N3) size.
Note that this is not the same receive window as
defined in IEEE 802.2 LLC. This is N3 which is the
number of I frames received before an RR frame is
sent (defined as N3 in IEEE 802.2 LLC).
Current allowable values are 1-7.
The default value for this field is 7.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.9 |
lanTxWindowSizeThe defalut LLC transmit window size.
Current allowable values are 1-7.
The default value for this field is 7.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.10 |
lanMaxRetriesThe default LLC maximum number of retries (N2 value).
Current allowable values are 1-99.
The default value for this field is 3.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.11 |
lanRingNumber802.5 bridging parameter.
This variable returns a value of 0, if it is not
defined.
This value is not applicable to Ethernet.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.12 |
lanBridgeNumber802.5 bridging parameter.
The default value for this field is 1.
This value is not applicable to Ethernet.ro INTEGER .1.3.6.1.4.1.485.3.4.2.1.1.13 |
lanEthernetFrameFormatThe Ethernet frame format used on this LAN.
The default value for this field is 802.3.
Not used if Token Ring, and 1 is returned.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.14 |
lanSendLocalTestThis port's send local test option.
Identifies whether a test frame should be sent on the
local ring to discover a destination MAC address.
If all destinations for the unit are located on a
remote ring, setting this field to No allows the unit
to bypass discovery of a destination MAC address on
the local ring. If this field is set to 'No' then
the broadcastType field must be set to all routes or
single route broadcast.
If the any destination is on a local ring or unknown,
this parameter should be set to 'Yes'.
The default value for this field is 'Yes'.
Not used if Ethernet, and 1 is returned.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.15 |
lanBroadcastTypeThis port's broadcast type. Not used if Ethernet.
Types are: none, all-routes, and single-route.
Identifies the form of a broadcast test frame
sent to discover the route to a destination MAC
address.
If all destinations are located on the local ring,
this field may be set to 'None' to prevent a
broadcast search for a destination MAC address. If
set to 'None', then the sendLocalTest field must be
set to 'Yes'.
If set as 'All-routes', the unit will send an
All-routes broadcast TEST command frame and expect a
non-broadcast TEST response frame in return.
If set to Single-route, the unit will send a
Single-route broadcast TEST command frame and expect a
all-routes TEST response frame in return.
The default for this field is all routes broadcast.
Not used if Ethernet, and 1 is returned.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.16 |
lanIPAddressThis is the IP Address of this interface.ro IpAddress .1.3.6.1.4.1.485.3.4.2.1.1.17 |
lanNetworkMaskThis is the network mask to be used on this
interface.ro IpAddress .1.3.6.1.4.1.485.3.4.2.1.1.18 |
lanDefaultGatewayDefault gateway address to be used when sending
responses on this interface.ro IpAddress .1.3.6.1.4.1.485.3.4.2.1.1.19 |
lanNAUNameThe NAU name of this port.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.4.2.1.1.20 |
lanInterfaceTypeThis port's physical interface type. Only used if
Ethernet. The default for this field is utp.
Not used if Token Ring, and 1 is returned.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.21 |
lanIPEthernetFrameTypeThe IP Ethernet frame format used on this LAN for IP
frames. The default value for this field is 802.3.
Not used if Token Ring, and 1 is returned.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.22 |
lanInitStateThe initial state of the LAN port.
If configured for 'in-service', then the LAN port will
be brougt up automattically when the unit is powered
up.
If configured for 'out-of-service', the the LAN port
must be manually enabled by operator intervention (i.e.
enable command must be sent).
The default value is 'enabled'.ro Enumeration .1.3.6.1.4.1.485.3.4.2.1.1.23 |
nodeLineGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.5 |
lineControlGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.5.1 |
lineControlTableA table for controlling lines and obtaining
information. SEQUENCE OF LineControlEntry .1.3.6.1.4.1.485.3.5.1.1 |
lineControlEntryAn entry consisting of port information for a
particular port. LineControlEntry .1.3.6.1.4.1.485.3.5.1.1.1 |
lineControlIndexThe port number that uniquely identifies
this port.ro INTEGER .1.3.6.1.4.1.485.3.5.1.1.1.1 |
lineControlTypeThe port type.
TSDLC (Terminal SDLC) ports emulate a Host
and poll the downstream PUs (e.g. 3274 or 3174
SDLC/SNA controllers).
HSDLC ports (Host SDLC) ports emulate a line with
Terminal Controllers (PUs) and respond to polls
from the Host or upstream PU.
TBSC (Terminal Bisync) ports emulate a Host
and poll the downstream CUs (e.g. 3274 or ATM
Bisync controllers).
HBSC ports (Host Bisync) ports emulate a line with
Terminal Controllers (CUs) and respond to polls
from the Host or upstream CU.
Frame Relay ports support Frame Relay PVC.
Future line types (e.g. X.25) may be added here.ro Enumeration .1.3.6.1.4.1.485.3.5.1.1.1.2 |
lineStatusThe status of the port.
To change status of a port an enable, enable all
or disable may be set.
Valid Return status are enable(d), disable(d),
or failed.
Commands:
An enable command will attempt to bring up the line.
An enable all command will attempt to bring up
the line and any lower layer entities (e.g. PUs).
A disable command will disable the line.
Status:
Enable(d) indicates the line is enabled and running.
Disable(d) indicates the line has been disabled.
Failed indicates the line is enabled and not
Running.rw Enumeration .1.3.6.1.4.1.485.3.5.1.1.1.3 |
lineControlFailureCodeThis entry contains the failure codes if the
associated port interface is in the failed state.ro OCTET STRING .1.3.6.1.4.1.485.3.5.1.1.1.4 |
lineControlNAUNameThe NAU name of this port.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.5.1.1.1.5 |
linePhysicalGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.5.2 |
linePhysicalTableA table for obtaining physical signal status
information. SEQUENCE OF LinePhysicalEntry .1.3.6.1.4.1.485.3.5.2.1 |
linePhysicalEntryAn entry consisting of port information for a
particular port. LinePhysicalEntry .1.3.6.1.4.1.485.3.5.2.1.1 |
linePhysicalIndexThe port number that uniquely identifies
this port.ro INTEGER .1.3.6.1.4.1.485.3.5.2.1.1.1 |
linePhysicalTypeThe port type.
TSDLC (Terminal SDLC) ports emulate a Host
and poll the downstream PUs (e.g. 3274 or 3174
SDLC/SNA controllers).
HSDLC ports (Host SDLC) ports emulate a line with
Terminal Controllers (PUs) and respond to polls
from the Host or upstream PU.
TBSC (Terminal Bisync) ports emulate a Host
and poll the downstream CUs (e.g. 3274 or ATM
Bisync controllers).
HBSC ports (Host Bisync) ports emulate a line with
Terminal Controllers (CUs) and respond to polls
from the Host or upstream CU.
Frame Relay ports support Frame Relay PVC.ro Enumeration .1.3.6.1.4.1.485.3.5.2.1.1.2 |
lineEIAStatusA port's current control signal status.
All SDLC ports have the ability to read
the current status of RS-232 or equivalent
control signals.
The value returned is a 16 bit value where each
bit signifies a signal status where 1 means the
signal is active and 0 means the signal is inactive.
The value returned is a snapshot taken when the
command actually is sent to the driver software and
wherever possible actually goes out to the driver
or receiver control chips to get the value.
Currently defined bit values are as follows*:
128 : Data Terminal Ready 0x0080 RS-232 pin 20
64 : Data Set Ready 0x0040 RS-232 pin 6
32 : Clear to Send 0x0020 RS-232 pin 5
16 : Clear to Send Ext. 0x0010 RS-232 pin 11**
8 : Data Carrier Detect 0x0008 RS-232 pin 8
4 : Busy Out 0x0004 RS-232 pin 25
2 : Request to send 0x0002 RS-232 pin 4
1 : Ring Indicator 0x0001 RS-232 pin 22
Note*: Bit values higher than 128 are reserved for
future use.
Note**: Clear to Send External is extended (non-
standard) pin and reserved for future use
by Sync Research.ro INTEGER .1.3.6.1.4.1.485.3.5.2.1.1.3 |
lineQualityFrameCountThis entry contains the number of frames received.
For every 255 incoming frames, a trap is generated by
the unit if lineQualityCRCErrors or lineQualityAborts
exceeds 5. When this value reaches its maximum, it
then rolls back to 0. Applicable to SDLC only.ro Counter .1.3.6.1.4.1.485.3.5.2.1.1.4 |
lineQualityCRCErrorsThis entry contains the number of frames with CRC
errors. For every 255 incoming frames, a trap is
generated by the unit if lineQualityCRCErrors or
lineQualityAborts exceeds 5. Applicable to SDLC only.ro Counter .1.3.6.1.4.1.485.3.5.2.1.1.5 |
lineQualityAbortsThis entry contains the number of aborts received.
For every 255 incoming frames, a trap is generated
by the unit if lineQualityCRCErrors or
lineQualityAborts exceeds 5.
Applicable to SDLC only.ro Counter .1.3.6.1.4.1.485.3.5.2.1.1.6 |
lineSDLCGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.5.3 |
sdlcConfigTableA table of SDLC information. SEQUENCE OF SdlcConfigEntry .1.3.6.1.4.1.485.3.5.3.1 |
sdlcConfigEntryAn entry consisting of port information for a
particular SDLC port. SdlcConfigEntry .1.3.6.1.4.1.485.3.5.3.1.1 |
sdlcConfigPortIndexThe port number that uniquely identifies
this port.
Current supported SDLC numbers are 1-4.ro INTEGER .1.3.6.1.4.1.485.3.5.3.1.1.1 |
sdlcConfigTypeThe port type.
TSDLC (Terminal SDLC) ports emulate a Host
and poll the downstream PUs (e.g. 3274 or 3174
SDLC/SNA controllers).
HSDLC ports (Host SDLC) ports emulate a line with
Terminal Controllers (PUs) and respond to polls
from the Host or upstream PU.
Note that all ports must currently be defined as
the same time for a given unit (i.e. no mixing of
HSDLC and TSDLC ports is allowed).ro Enumeration .1.3.6.1.4.1.485.3.5.3.1.1.2 |
sdlcInitStateThe initial state of the SDLC port.
If configured for 'in-service', then the SDLC port will
be brougt up automattically when the unit is powered
up.
If configured for 'out-of-service', the the SDLC port must
be manually enabled by operator intervention (i.e.
enable command must be sent).
The default value is 'enabled'.ro Enumeration .1.3.6.1.4.1.485.3.5.3.1.1.3 |
sdlcCarrierThis field indicates whether Carrier (a.k.a. CD or
DCD, RS-232 pin 8) is constant or switched for
DCE devices (internally clocked), or Request To
Send (a.k.a. RTS, RS-232 pin 4) is constant or
switched.
This parameter also affects SDLC flag generation.
If configured for constant then the line will
transmit flags in an idle (no data being sent) state.
If configured for switched then the line will
transmit all one bits (mark state).
The default value for this parameter is 'constant'.ro Enumeration .1.3.6.1.4.1.485.3.5.3.1.1.4 |
sdlcClockingClocking source for this port.
Setting 'internal' will cause the
port to emulate a physical DCE, and setting
external will cause the port to emulate a
physical DTE.
X21 External and Internal are used (with the
proper external adapter) to support X.21 Leased
Line operation for RS-422/RS-530 (25 pin balanced)
interfaces. X21 operation is not supported for
boards that operate RS-232 or V.35.
The default value for this field is 'external'.ro Enumeration .1.3.6.1.4.1.485.3.5.3.1.1.5 |
sdlcSpeedThe ports speed in bits per second.
The default value is 9600 bits per second.
Speeds higher than 19200 are not supported on
RS-232 ports units (must be V.35 or RS-422).ro INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640), -- speed128000(1280) -- } .1.3.6.1.4.1.485.3.5.3.1.1.6 |
sdlcPauseThis parameter defines the amount of time
between polls in 1/100 second (10 millisecond)
intervals. If set to zero then the port will
poll the PUs as fast as possible. The minimum
value for this parameter is 5 and the timer
has a resolution of 25 milliseconds.
The default value is 20 (.20 seconds).
This field is not applicable to Host port. It
returns a dummy value.ro INTEGER .1.3.6.1.4.1.485.3.5.3.1.1.7 |
sdlcNRZIThis parameter indicates whether the port is
configured for NRZI (yes) or NRZ (no) bit
encoding.
The default value is 'No' (NRZ encoding selected).ro Enumeration .1.3.6.1.4.1.485.3.5.3.1.1.8 |
sdlcT1TimerThe SDLC T1 timer value in 20ths of a second.
The default value is 20 (5 seconds).
This field is not applicable to Host ports. It
returns a dummy value.ro INTEGER .1.3.6.1.4.1.485.3.5.3.1.1.9 |
sdlcSlowPollTimerThe slow poll timer value in 20ths of a second.
The slow poll timer is the amount of time to wait
to contact (send SNRM) failed PUs.
The default value for this field is 600 (30 seconds).
This field is not applicable to Host ports. It
returns a dummy value.ro INTEGER .1.3.6.1.4.1.485.3.5.3.1.1.10 |
sdlcMaxRetriesThe maximum number of retries (N2 value) before
failing a PU.
The default value for this field is 3.
This field is not applicable to Host ports. It
returns a dummy value.ro INTEGER .1.3.6.1.4.1.485.3.5.3.1.1.11 |
sdlcNAUNameThe NAU name of this port.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.5.3.1.1.12 |
sdlcMultiFlagInsertionThis parameter indicates whether the port is
configured to send multiple interframe flags.
The default value is 'No' (single flags).ro Enumeration .1.3.6.1.4.1.485.3.5.3.1.1.13 |
sdlcStatsTableA table of SDLC information. SEQUENCE OF SdlcStatsEntry .1.3.6.1.4.1.485.3.5.3.2 |
sdlcStatsEntryAn entry consisting of port information for a
particular SDLC port. SdlcStatsEntry .1.3.6.1.4.1.485.3.5.3.2.1 |
sdlcStatsPortIndexThe port number that uniquely identifies
this SDLC port.
Current supported numbers on are 1-4.ro INTEGER .1.3.6.1.4.1.485.3.5.3.2.1.1 |
sdlcPortTypeThe port type.
TSDLC (Terminal SDLC) ports emulate a Host
and poll the downstream PUs (e.g. 3274 or 3174
SDLC/SNA controllers).
HSDLC ports (Host SDLC) ports emulate a line with
Terminal Controllers (PUs) and respond to polls
from the Host or upstream PU.ro Enumeration .1.3.6.1.4.1.485.3.5.3.2.1.2 |
sdlcInOctetsThe number of bytes received.ro Counter .1.3.6.1.4.1.485.3.5.3.2.1.3 |
sdlcOutOctetsThe number of bytes sent.ro Counter .1.3.6.1.4.1.485.3.5.3.2.1.4 |
sdlcInFramesThe number of I-frames received.ro Counter .1.3.6.1.4.1.485.3.5.3.2.1.5 |
sdlcOutFramesThe number of I-frames sent.ro Counter .1.3.6.1.4.1.485.3.5.3.2.1.6 |
sdlcOverrunsThe number of overruns.ro Counter .1.3.6.1.4.1.485.3.5.3.2.1.7 |
sdlcCRCErrorsThe number of CRC errors.ro Counter .1.3.6.1.4.1.485.3.5.3.2.1.8 |
sdlcRecvAbortsThe number of aborts received.ro Counter .1.3.6.1.4.1.485.3.5.3.2.1.9 |
lineBisyncGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.5.4 |
bisyncConfigTableA table of Bisync port information. SEQUENCE OF BisyncConfigEntry .1.3.6.1.4.1.485.3.5.4.1 |
bisyncConfigEntryAn entry consisting of port information for a
particular Bisync port. BisyncConfigEntry .1.3.6.1.4.1.485.3.5.4.1.1 |
bisyncConfigPortIndexThe port number that uniquely identifies
this port.
Current supported Bisync numbers are 1-4.ro INTEGER .1.3.6.1.4.1.485.3.5.4.1.1.1 |
bisyncConfigTypeThe port type.
TBSC (Terminal Bisync) ports emulate a Host
and polls the downstream controllers).
HBSC ports (Host Bisync) ports emulate a line with
Terminal Controllers (CUs) and respond to polls
from the Host.ro Enumeration .1.3.6.1.4.1.485.3.5.4.1.1.2 |
bisyncNAUNameThe NAU name of this port.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.5.4.1.1.3 |
bisyncInitStateThe initial state of the Bisync port.
If configured for 'in-service', then the Bisync port will
be brougt up automattically when the unit is powered
up.
If configured for 'out-of-service', then the Bisync port must
be manually enabled by operator intervention (i.e.
enable command must be sent).
The default value is 'enabled'.ro Enumeration .1.3.6.1.4.1.485.3.5.4.1.1.4 |
bisyncCarrierThis field indicates whether Carrier (a.k.a. CD or
DCD, RS-232 pin 8) is constant or switched for
DCE devices (internally clocked), or Request To
Send (a.k.a. RTS, RS-232 pin 4) is constant or
switched.
The default value for this parameter is 'constant'.ro Enumeration .1.3.6.1.4.1.485.3.5.4.1.1.5 |
bisyncClockingClocking source for this port.
Setting 'internal' will cause the
port to emulate a physical DCE, and setting
external will cause the port to emulate a
physical DTE.
X21 External and Internal are used (with the
proper external adapter) to support X.21 Leased
Line operation for RS-422/RS-530 (25 pin balanced)
interfaces. X21 operation is not supported for
boards that operate RS-232 or V.35.
The default value for this field is 'external'.ro Enumeration .1.3.6.1.4.1.485.3.5.4.1.1.6 |
bisyncSpeedThe ports speed in bits per second.
The default value is 9600 bits per second.
Speeds higher than 64000 are not supported.ro INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640) -- } .1.3.6.1.4.1.485.3.5.4.1.1.7 |
bisyncPauseThis parameter defines the amount of time
between polls in 1/100 second (10 millisecond)
intervals. If set to zero then the port will
poll the CUs as fast as possible. The minimum
value for this parameter is 5 and the timer
has a resolution of 25 milliseconds.
The default value is 20 (.20 seconds).
This field is not applicable to a Host port. It
returns a dummy value.ro INTEGER .1.3.6.1.4.1.485.3.5.4.1.1.8 |
bisyncReplyTimerThe time to wait for a response in seconds.
The default value for this field is 3 seconds.ro INTEGER .1.3.6.1.4.1.485.3.5.4.1.1.9 |
bisyncRetriesThe maximum number of retries (N2 value) before
failing a CU.
The default value for this field is 5.ro INTEGER .1.3.6.1.4.1.485.3.5.4.1.1.10 |
bisyncSlowpollTimerThe time to wait in seconds before attempting a
slowpoll.
The default value for this field is 30 seconds.ro INTEGER .1.3.6.1.4.1.485.3.5.4.1.1.11 |
bisyncSessTermThe type of session termination used. Only
applies to Host BSC ports.ro Enumeration .1.3.6.1.4.1.485.3.5.4.1.1.12 |
bisyncStatsTableA table of Bisync information. SEQUENCE OF BisyncStatsEntry .1.3.6.1.4.1.485.3.5.4.2 |
bisyncStatsEntryAn entry consisting of port information for a
particular Bisync port. BisyncStatsEntry .1.3.6.1.4.1.485.3.5.4.2.1 |
bisyncStatsPortIndexThe port number that uniquely identifies
this Bisync port.
Current supported numbers are 1-4.ro INTEGER .1.3.6.1.4.1.485.3.5.4.2.1.1 |
bisyncPortTypeThe port type.
TBSC (Terminal Bisync) ports emulate a Host
and poll the downstream controllers).
HBSC ports (Host Bisync) ports emulate a line with
Terminal Controllers (PUs) and respond to polls
from the Host or upstream PU.ro Enumeration .1.3.6.1.4.1.485.3.5.4.2.1.2 |
bisyncInOctetsThe number of bytes received.ro Counter .1.3.6.1.4.1.485.3.5.4.2.1.3 |
bisyncOutOctetsThe number of bytes sent.ro Counter .1.3.6.1.4.1.485.3.5.4.2.1.4 |
bisyncOverrunsThe number of receiver overruns.ro Counter .1.3.6.1.4.1.485.3.5.4.2.1.5 |
bisyncCRCErrorsThe number of receive frame CRC errors.ro Counter .1.3.6.1.4.1.485.3.5.4.2.1.6 |
bisyncRcvTimeoutThe number of receive timeout.ro Counter .1.3.6.1.4.1.485.3.5.4.2.1.7 |
bisyncXmtTimeoutThe number of transmit timeout.ro Counter .1.3.6.1.4.1.485.3.5.4.2.1.8 |
lineFrameRelayGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.5.5 |
frameRelayConfigTableA table of Sync product Frame Relay information. SEQUENCE OF FrameRelayConfigEntry .1.3.6.1.4.1.485.3.5.5.1 |
frameRelayConfigEntryAn entry consisting of port information for a
particular Sync product Frame Relay port. FrameRelayConfigEntry .1.3.6.1.4.1.485.3.5.5.1.1 |
frameRelayConfigPortIndexThe port number that uniquely identifies
this port.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.1 |
frameRelayPortTypeThe Frame Relay port type.ro Enumeration .1.3.6.1.4.1.485.3.5.5.1.1.2 |
frameRelayInitStateThe initial state of the Frame Relay port.
If configured for 'in-service', then the Frame Relay port will
be brougt up automatically when the unit is powered
up.
If configured for 'out-of-service', then the Frame Relay port must
be manually enabled by operator intervention (i.e.
enable command must be sent).
The default value is 'enabled'.ro Enumeration .1.3.6.1.4.1.485.3.5.5.1.1.3 |
frameRelayClockingClocking source for this port.
Setting 'internal' will cause the
port to emulate a physical DCE, and setting
external will cause the port to emulate a
physical DTE.
X21 External and Internal are used (with the
proper external adapter) to support X.21 Leased
Line operation for RS-422/RS-530 (25 pin balanced)
interfaces. X21 operation is not supported for
boards that operate RS-232 or V.35.
The default value for this field is 'external'.ro Enumeration .1.3.6.1.4.1.485.3.5.5.1.1.4 |
frameRelaySpeedThe ports speed in bits per second.
The default value is 9600 bits per second.
Speeds higher than 19200 are not supported on
RS-232 port Sync products (must be V.35 or RS-422).ro INTEGER -- { -- speed1200(12), -- speed2000(20), -- speed2400(24), -- speed3600(36), -- speed4800(48), -- speed7200(72), -- speed9600(96), -- speed14400(144), -- speed19200(192), -- speed28800(288), -- speed48000(480), -- speed56000(560), -- speed64000(640), -- speed128000(1280), -- speed256000(2560) -- } .1.3.6.1.4.1.485.3.5.5.1.1.5 |
frameRelayLocalManagementProtocolThe ports management protocol type.
Annex D = ANSI T1.617 Annex D
LMI = Frame Relay Manufacturers LMI
The default value is Annex D.ro Enumeration .1.3.6.1.4.1.485.3.5.5.1.1.6 |
frameRelayLinkPollingTimerMeasured in seconds, intervals of 5
T391 - Annex D
nT1 - LMI
The default value for this field is 5 seconds.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.7 |
frameRelayFullStatusPollingCountThe number of polls that a full status poll is
issued.
N391 - Annex D
nT1 - LMI
The default value for this field is 6.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.8 |
frameRelayT1TimerThe default LLC T1 timer value in seconds.
T1 should be greater than T2 and less than Ti.
Currently supported values are 1 to 25 seconds.
The default value for this field is 3 seconds.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.9 |
frameRelayT2TimerThe default LLC T2 timer value in tenths of seconds.
If configured for 0 then the T2 timer is disabled
and an RR frame will be sent for every I frame
received.
Current supported values are 0 and 2-50.
T2 should be less than T1.
The default value for this field is 0 (disabled).ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.10 |
frameRelayTiTimerThe default LLC Ti (inactivity) timer value
in seconds.
Ti should be greater than T1.
Currently supported values are 2 to 50 seconds.
The default value for this field is 30 seconds.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.11 |
frameRelayRxWindowSizeThe default LLC receive window (N3) size.
Note that this is not the same receive window as
defined in IEEE 802.2 LLC. This is N3 which is the
number of I frames received before an RR frame is
sent (defined as N3 in IEEE 802.2 LLC).
Current allowable values are 1-7.
The default value for this field is 7.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.12 |
frameRelayTxWindowSizeThe defalut LLC transmit window size.
Current allowable values are 1-7.
The default value for this field is 7.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.13 |
frameRelayMaxRetriesThe default LLC maximum number of retries (N2 value).
The default value for this field is 15.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.14 |
frameRelayNAUNameThe NAU name of this port.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.5.5.1.1.15 |
frameRelayVirtualMACAddressThe F/R WAN is treated as a token ring. This address is
used for communication with other bridges in the
network.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.485.3.5.5.1.1.16 |
frameRelayVirtualRingNumberThe F/R WAN is treated as a token ring. This is the ring
number for the F/R network to which the port is attached.
It must be a unique ring number in the network.
The default value for this field is 1.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.17 |
frameRelayVirtualBridgeNumberThe F/R WAN is treated as a token ring. This variable only
has significance if more than 1 F/R port is configured.
The default value for this field is 1.ro INTEGER .1.3.6.1.4.1.485.3.5.5.1.1.18 |
frameRelayIPAddressThis is the IP Address of this interface.ro IpAddress .1.3.6.1.4.1.485.3.5.5.1.1.19 |
frameRelayNetworkMaskThis is the network mask to be used on this
interface.ro IpAddress .1.3.6.1.4.1.485.3.5.5.1.1.20 |
frameRelayDefaultGatewayAddressDefault gateway address to be used when sending
responses on this interface.ro IpAddress .1.3.6.1.4.1.485.3.5.5.1.1.21 |
frameRelayStatsTableA table of Frame Relay information. SEQUENCE OF FrameRelayStatsEntry .1.3.6.1.4.1.485.3.5.5.2 |
frameRelayStatsEntryAn entry consisting of port information for a
particular Frame Relay port. FrameRelayStatsEntry .1.3.6.1.4.1.485.3.5.5.2.1 |
frameRelayStatsPortIndexThe port number that uniquely identifies
this Frame Relay port.ro INTEGER .1.3.6.1.4.1.485.3.5.5.2.1.1 |
frameRelayInOctetsThe number of bytes received inclusive
of all valid bytes in the frame relay
frame except for the CRC field (frame
relay header included).ro Counter .1.3.6.1.4.1.485.3.5.5.2.1.2 |
frameRelayOutOctetsThe number of bytes transmitted inclusive
of all bytes in the frame relay
frame except for the CRC field (frame
relay header included).ro Counter .1.3.6.1.4.1.485.3.5.5.2.1.3 |
frameRelaySampleDurationThe sample duration in seconds for
Frame Relay Statistics for this port.ro INTEGER .1.3.6.1.4.1.485.3.5.5.2.1.4 |
frameRelayOverrunsThe number of receiver overruns.ro Counter .1.3.6.1.4.1.485.3.5.5.2.1.5 |
frameRelayCRCErrorsThe number of received CRC errors.ro Counter .1.3.6.1.4.1.485.3.5.5.2.1.6 |
frameRelayRecvAbortsThe number of received frame aborts
received.ro Counter .1.3.6.1.4.1.485.3.5.5.2.1.7 |
nodePUGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.6 |
puControlGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.6.1 |
puControlTableA table for controlling lines and obtaining
information. SEQUENCE OF PuControlEntry .1.3.6.1.4.1.485.3.6.1.1 |
puControlEntryAn entry consisting of PU information for a
particular port. PuControlEntry .1.3.6.1.4.1.485.3.6.1.1.1 |
puControlLineIndexThe port number that has a given PU.ro INTEGER .1.3.6.1.4.1.485.3.6.1.1.1.1 |
puControlPUAddressThe PU address in the range of 0x01 to 0xfe.ro OCTET STRING .1.3.6.1.4.1.485.3.6.1.1.1.2 |
puStatusThe status of the PU.
To change status of a port an enable, enable all
or disable may be set.
Valid Return status are enable(d), disable(d),
or failed.
Commands:
An enable command will attempt to bring up the PU.
An enable all command will attempt to bring up
the line and any lower layer entities (e.g. PUs).
A disable command will disable the PU.
Status:
Enable(d) indicates the PU is enabled and running.
Disable(d) indicates the PU has been disabled.
Failed indicates the PU is enabled and not
Running.rw Enumeration .1.3.6.1.4.1.485.3.6.1.1.1.3 |
puConnectionStatusThe status of the LLC type 2 Connection for this
SDLC PU.ro Enumeration .1.3.6.1.4.1.485.3.6.1.1.1.4 |
puLastClearCodeA two octet field indicating the Last Clearing
Cause and Diagnostic Field of the last failed
connection attempt (a.k.a. call attempt) or
active connection (a.k.a. session).
For LLC type 2 connections the first octet (cause)
is always 0. The second octet (diagnostic)
indicates the reason for the last connection failure.
The second octet is set to 0 when a sucessful
call has been placed, or if no call has ever been
placed (e.g. PU never came up).
If the second octet is non-zero then it indicates
the reason for the connection attempt failure.
See User's Guide for informationro OCTET STRING .1.3.6.1.4.1.485.3.6.1.1.1.5 |
puControlFailureCodeThis entry contains the failure codes if the
associated PU is in the failed state.ro OCTET STRING .1.3.6.1.4.1.485.3.6.1.1.1.6 |
puControlNAUNameThe NAU name of this PU.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.6.1.1.1.7 |
puConnectionAttemptCountThe number of connection attempts performed. This
count is set to zero at startup, and after every
loss of an estabished session.ro Counter .1.3.6.1.4.1.485.3.6.1.1.1.8 |
puSDLCGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.6.2 |
sdlcPuConfigTableA list of PU entries. SEQUENCE OF SdlcPuConfigEntry .1.3.6.1.4.1.485.3.6.2.1 |
sdlcPuConfigEntryThis entry contains information about
a given PU. The entry is indexed by the
port number and the PU number. SdlcPuConfigEntry .1.3.6.1.4.1.485.3.6.2.1.1 |
sdlcPuConfigLineIndexThe port number for which the line (CU)is configured
(first level).ro INTEGER .1.3.6.1.4.1.485.3.6.2.1.1.1 |
sdlcPuConfigAddressThe PU address in the range of 0x00 to 0xfe.ro OCTET STRING .1.3.6.1.4.1.485.3.6.2.1.1.2 |
sdlcPuNAUNameThe NAU name of this PU.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.6.2.1.1.3 |
sdlcPuInitialStateThe initial state of the PU.
If configured for 'in-service', then the SDLC PU will
be brougt up automattically when the unit is powered
up.
If configured for 'out-of-service', the the SDLC PU must
be manually enabled by operator intervention (i.e.
enable command must be sent).
The default value is 'in-service'.ro Enumeration .1.3.6.1.4.1.485.3.6.2.1.1.4 |
sdlcPuXIDThe XID value for this PU.
The XID is used to identify the PU during the LLC
connection process to the remote Host or Gateway.
If the field is configured to 0 then the unit
will solicit the XID from the downstream PU
and send the XID data received from SDLC to the XID
data sent for the LLC connection process.
If not sent to 0, then the unit will insert the
data configured in the LLC sent to the host
during the LLC connection process on behalf of
the CU.
For incoming LLC connections on Sync Research
products this field is parsed to route the
connection to the proper PU.
The default value for this field is all zeroes
(solicit XID from PU).ro OCTET STRING .1.3.6.1.4.1.485.3.6.2.1.1.5 |
sdlcPuTypeThe SNA PU type.
1 = PU type 1
2 = PU type 2
3 = PU type 2.1
4 = PU type 4 (not supported, reserved)
5 = PU type 5 (not supported, reserved)
This parameter defaults to a value of 2.ro Enumeration .1.3.6.1.4.1.485.3.6.2.1.1.6 |
sdlcPuGroupPollAddressThe PU's group address in the range of 0x01 to 0xfe.
setting this value to 0 will disable the group poll
feature for polling this and other PUs in a group.
The default value for this field is 0.ro OCTET STRING .1.3.6.1.4.1.485.3.6.2.1.1.7 |
sdlcPuConnectionIDThis entry defines the Connection ID
to a corresponding entry in the mapping table.
The default value for this field is all zeroes.ro OCTET STRING .1.3.6.1.4.1.485.3.6.2.1.1.8 |
sdlcPuMAXOUTThis entry defines the maximum number of outstanding
I frames that the PU will allow.
This field is applicable to TSDLC only.ro INTEGER .1.3.6.1.4.1.485.3.6.2.1.1.9 |
sdlcPuConnectTypeThe SNA PU Connection type.ro Enumeration .1.3.6.1.4.1.485.3.6.2.1.1.10 |
sdlcPuStatsTableA list of PU statistics entries. SEQUENCE OF SdlcPuStatsEntry .1.3.6.1.4.1.485.3.6.2.2 |
sdlcPuStatsEntryThis entry contains information about
a given PU. The entry is indexed by the
port number and the PU number. SdlcPuStatsEntry .1.3.6.1.4.1.485.3.6.2.2.1 |
sdlcPuStatsLineIndexThe port number for which PU is configured on.ro INTEGER .1.3.6.1.4.1.485.3.6.2.2.1.1 |
sdlcPuStatsAddressThe PU address in the range of 0x00 to 0xfe.ro OCTET STRING .1.3.6.1.4.1.485.3.6.2.2.1.2 |
sdlcPuInIFramesThe number of I frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.3 |
sdlcPuOutIFramesThe number of I frames trasnmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.4 |
sdlcPuInRRFramesThe number of RR frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.5 |
sdlcPuOutRRFramesThe number of RR frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.6 |
sdlcPuInRNRFramesThe number of RNR frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.7 |
sdlcPuOutRNRFramesThe number of RNR frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.8 |
sdlcPuInXIDFramesThe number of XID frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.9 |
sdlcPuOutXIDFramesThe number of XID frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.10 |
sdlcPuInTESTFramesThe number of TEST frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.11 |
sdlcPuOutTESTFramesThe number of TEST frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.12 |
sdlcPuInSNRMFramesThe number of SNRM frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.13 |
sdlcPuOutSNRMFramesThe number of SNRM frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.14 |
sdlcPuInDISCFramesThe number of DISC frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.15 |
sdlcPuOutDISCFramesThe number of DISC frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.16 |
sdlcPuInDMFramesThe number of DM frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.17 |
sdlcPuOutDMFramesThe number of DM frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.18 |
sdlcPuInUAFramesThe number of UA frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.19 |
sdlcPuOutUAFramesThe number of UA frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.20 |
sdlcPuInFRMRFramesThe number of FRMR frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.21 |
sdlcPuOutFRMRFramesThe number of FRMR frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.22 |
sdlcPuInRDFramesThe number of RD frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.23 |
sdlcPuOutRDFramesThe number of RD frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.24 |
sdlcPuInUIFramesThe number of UI frames received on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.25 |
sdlcPuOutUIFramesThe number of UI frames transmitted on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.26 |
sdlcPuReTxIFramesThe number of re-transmitted I frames on this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.27 |
sdlcPuPollResponseTimeoutsThe number of PU Poll Response timeouts for this PU.ro Counter .1.3.6.1.4.1.485.3.6.2.2.1.28 |
puBisyncGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.6.3 |
bisyncPuConfigTableA list of Bisync CU entries. SEQUENCE OF BisyncPuConfigEntry .1.3.6.1.4.1.485.3.6.3.1 |
bisyncPuConfigEntryThis entry contains information about
a given PU. The entry is indexed by the
port number and the PU number. BisyncPuConfigEntry .1.3.6.1.4.1.485.3.6.3.1.1 |
bisyncPuConfigLineIndexThe port number for which PU is configured on.ro INTEGER .1.3.6.1.4.1.485.3.6.3.1.1.1 |
bisyncPuConfigAddressThe PU address in the range of 0x00 to 0xfe.ro OCTET STRING .1.3.6.1.4.1.485.3.6.3.1.1.2 |
bisyncPuNAUNameThe NAU name of this PU.
The default value for this field is all blank
(filled with ASCII space 0x20 characters).ro DisplayString .1.3.6.1.4.1.485.3.6.3.1.1.3 |
bisyncPuInitialStateThe initial state of the PU.
If configured for 'in-service', then the SDLC PU will
be brougt up automattically when the unit is powered
up.
If configured for 'out-of-service', the the SDLC PU must
be manually enabled by operator intervention (i.e.
enable command must be sent).
The default value is 'in-service'.ro Enumeration .1.3.6.1.4.1.485.3.6.3.1.1.4 |
bisyncPuXIDThe XID value for this PU.
The XID is used to identify the PU during the LLC
connection process to the remote Host or Gateway.
The unit will insert the
data configured in the LLC XID sent to the host
during the LLC connection process on behalf of
the CU.
For bisync control units, this field is required
as bisync cannot solicit an XID.
For incoming LLC connections on Sync Research
products this field is parsed to route the
connection to the proper PU.
The default value for this field is all zeroes.ro OCTET STRING .1.3.6.1.4.1.485.3.6.3.1.1.5 |
bisyncPuTargetHostTypeThe Target Host type.
1 = SNA host type
2 = Bisync host type
This field specifies the target host type for TBSC
and is applicable to BSC-to-SNA conversion only.
This parameter defaults to a value of 2.ro Enumeration .1.3.6.1.4.1.485.3.6.3.1.1.6 |
bisyncPuMaxDataThis entry defines the SNA frame size which is
the sum of SNA data and SNA header. This value must
match the MAXData configured for SNA host and is
applicable to BSC-to-SNA conversion only.
The default value is 521. The valid range is 265,
521, 777, 1033, 1289.ro INTEGER .1.3.6.1.4.1.485.3.6.3.1.1.7 |
bisyncPuConnectionIDThis entry defines the Connection ID
to a corresponding entry in the mapping table.
The default value for this field is all zeroes.ro OCTET STRING .1.3.6.1.4.1.485.3.6.3.1.1.8 |
bisyncPuConnectTypeThe Bisync PU Connection type.ro Enumeration .1.3.6.1.4.1.485.3.6.3.1.1.9 |
bisyncPuStatsTableA list of PU statistics entries. SEQUENCE OF BisyncPuStatsEntry .1.3.6.1.4.1.485.3.6.3.2 |
bisyncPuStatsEntryThis entry contains information about
a given PU. The entry is indexed by the
port number and the PU number. BisyncPuStatsEntry .1.3.6.1.4.1.485.3.6.3.2.1 |
bisyncPuStatsLineIndexThe port number for which PU is configured on.ro INTEGER .1.3.6.1.4.1.485.3.6.3.2.1.1 |
bisyncPuStatsAddressThe PU address in the range of 0x00 to 0xfe.ro OCTET STRING .1.3.6.1.4.1.485.3.6.3.2.1.2 |
bisyncPuInTransactionsThe number of PU Poll Response timeouts for this PU.ro Counter .1.3.6.1.4.1.485.3.6.3.2.1.3 |
bisyncPuOutTransactionsThe number of PU Poll Response timeouts for this PU.ro Counter .1.3.6.1.4.1.485.3.6.3.2.1.4 |
bisyncPuSlowPollsThe number of PU slow polls for this PU.ro Counter .1.3.6.1.4.1.485.3.6.3.2.1.5 |
bisyncPuPollsThe number of PU Polls for this PU.ro Counter .1.3.6.1.4.1.485.3.6.3.2.1.6 |
puMappingGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.6.4 |
mappingPuConfigTableA list of PU mapping entries. SEQUENCE OF MappingPuConfigEntry .1.3.6.1.4.1.485.3.6.4.1 |
mappingPuConfigEntryThis entry contains information about a given
mapping PU. Each entry includes MAC/SAP
information for a source PU and a similar
information for the partner (mapped) PU.
Depending upon whether the PU is LAN-attached,
SDLC-attached or Frame Relay-attached, one
or more fields may not apply. Some fields,
for example, mappingPuNAU, mappingPuXID,
mappingPuConnectID are common to both end
points. The entry is indexed by the port
number and the PU number. MappingPuConfigEntry .1.3.6.1.4.1.485.3.6.4.1.1 |
mappingPuConfigLineIndexThe port number for which PU is associated with.
Port number 99 is a special value which is used to
indicate NetView PU.ro INTEGER .1.3.6.1.4.1.485.3.6.4.1.1.1 |
mappingPuConfigAddressThe PU address in the range of 0x01 to 0xfe.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.2 |
mappingPuSourceSAPThe LLC source SAP value for this PU.
Typically the source SAP will vary for each PU.
This is due to the fact that most Sync products are
configured to always call the same remote
Token-Ring Host or Gateway for all connections
configured. This means that all the Destination
SAP (usually set to 4) and Destination MAC addresses
are the same, so the Source SAP field must be set
to a unique value in order to uniquely identify
the LLC connection to the Host. (SNA does not allow
multiplexing of PUs on one LLC connection. Each
PU must have its own LLC Type 2 connection.)
This field must be set to a range between 04 and
E8 hexadecimal and it must be evenly divisible by
4 (802.2 LLC rules for user assigned SAPs).
This field is not applicable in all cases, if not it
returns a dummy value.
This parameter defaults to a value of 4.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.3 |
mappingPuDestinationSAPThe LLC Destination SAP value for this PU.
For SNA typically the destination is almost
always SAP 4. However both Host Front Ends
(e.g. 3745) or Gateways (e.g. 3174) allow SAPs
to be configured for any value betwee 0x04 and
0xEC as long as the SAP ID is a user assignable
individual SAP ID (any value evenly divisable
by 4).
This field is not applicable to all cases. If not it
returns a dummy value.
This parameter defaults to a value of 4.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.4 |
mappingPuDestinationMACThe LAN Destination MAC address used in
the LLC Type 2 connection for this PU.
The Token-Ring format for this field is a 6 octet
(48 bit) field represented in IEEE 802.5 format where
the first bit transmitted is the most significant bit.
The destination MAC must also be an 'Individual'
address. Therefore valid addresses are between
000000000001 and 7FFFFFFFFFFF (an address of all
zeroes is not supported).
The Ethernet format for this field is a 6 octet
(48 bit) field represented in IEEE 802.3 format where
the first bit transmitted is the least significant bit.
The destination MAC must also be an 'Individual'
address. Therefore valid addresses must start
with the least significant bit equal to 0. In other
words, the first two digits must be in the set
of 0x00, 0x02, 0x04, ... 0xFE (an address of all
12 digits equal to zeroes is not supported).
This field is not applicable to all cases. If not it
returns a dummy value.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.485.3.6.4.1.1.5 |
mappingPuPartnerConfigLineIndexThe port number for the partner PU associated with
source PU. Port number 99 is a special value which
is used to indicate NetView PU.ro INTEGER .1.3.6.1.4.1.485.3.6.4.1.1.6 |
mappingPuPartnerConfigAddressThe PU address of the partner PU in the range of
0x01 to 0xfe.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.7 |
mappingPuPartnerSourceSAPThe LLC source SAP value for a partner PU.
Typically the source SAP will vary for each PU.
This is due to the fact that most Sync products are
configured to always call the same remote
Token-Ring Host or Gateway for all connections
configured. This means that all the Destination
SAP (usually set to 4) and Destination MAC addresses
are the same, so the Source SAP field must be set
to a unique value in order to uniquely identify
the LLC connection to the Host. (SNA does not allow
multiplexing of PUs on one LLC connection. Each
PU must have its own LLC Type 2 connection.)
This field must be set to a range between 04 and
E8 hexadecimal and it must be evenly divisible by
4 (802.2 LLC rules for user assigned SAPs).
This field is not applicable in all cases, if not it
returns a dummy value.
This parameter defaults to a value of 4.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.8 |
mappingPuPartnerDestSAPThe LLC Destination SAP value for the partner PU.
For SNA typically the destination is almost
always SAP 4. However both Host Front Ends
(e.g. 3745) or Gateways (e.g. 3174) allow SAPs
to be configured for any value betwee 0x04 and
0xEC as long as the SAP ID is a user assignable
individual SAP ID (any value evenly divisable
by 4).
This field is not applicable to all cases. It
returns a dummy value.
This parameter defaults to a value of 4.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.9 |
mappingPuPartnerDestMACThe LAN Destination MAC address used in
the LLC Type 2 connection for the partner PU.
The Token-Ring format for this field is a 6 octet
(48 bit) field represented in IEEE 802.5 format where
the first bit transmitted is the most significant bit.
The destination MAC must also be an 'Individual'
address. Therefore valid addresses are between
000000000001 and 7FFFFFFFFFFF (an address of all
zeroes is not supported).
The Ethernet format for this field is a 6 octet
(48 bit) field represented in IEEE 802.3 format where
the first bit transmitted is the least significant bit.
The destination MAC must also be an 'Individual'
address. Therefore valid addresses must start
with the least significant bit equal to 0. In other
words, the first two digits must be in the set
of 0x00, 0x02, 0x04, ... 0xFE (an address of all
12 digits equal to zeroes is not supported).
This field is not applicable to all cases. If not it
returns a dummy value.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.485.3.6.4.1.1.10 |
mappingPuNAUThe NAU Name. The NAU name is same for both the
source PU and the partner PU. It represents one
physical PU in a network.ro DisplayString .1.3.6.1.4.1.485.3.6.4.1.1.11 |
mappingPuConnectIDThe connection ID. This must match a connection ID
of an access line PU or another mapping PU Connection
ID.
The connnection ID is 0 if there is no mapping.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.12 |
mappingPuXIDThe XID value for this PU.
The XID is used to identify the PU during the LLC
connection process to the remote Host or Gateway.
For incoming LLC connections on Sync Research
products this field is parsed to route the
connection to the proper PU.
The XID is same for both the source PU and the partner
PU. It represents one physical PU in a network.
The default value for this field is all zeroes.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.13 |
mappingPuDirectDLCIThe Frame Relay DLCI used in
the LLC Type 2 connection for this PU.
The Frame Relay format for this field is a 2
octet (16 bit) field represented in BCD format.
A valid DLCI would be from 0001 to 1023 (0000 is
reserved for AnnexD management. 1023 is reserved for
LMI mangement.).
This value is applicable to Frame Relay-attached PU
only. The field corresponds to a source port or a
partner port depending upon whether the source PU is
a Frame Relay-attached PU or the partner PU is
Frame Relay-attached PU. For Frame Relay-attached PU
if this value is not configured, 0 is returned.ro OCTET STRING .1.3.6.1.4.1.485.3.6.4.1.1.14 |
nodeDeviceGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.7 |
deviceControlGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.7.1 |
deviceControlTableA table for controlling devices and obtaining
information. SEQUENCE OF DeviceControlEntry .1.3.6.1.4.1.485.3.7.1.1 |
deviceControlEntryAn entry consisting of device information for a
particular device. DeviceControlEntry .1.3.6.1.4.1.485.3.7.1.1.1 |
deviceControlIndexThe number that uniquely identifies
this device.ro INTEGER .1.3.6.1.4.1.485.3.7.1.1.1.1 |
deviceControlCUIndexThe CU index for this device.ro INTEGER .1.3.6.1.4.1.485.3.7.1.1.1.2 |
deviceControlAddressThe device address.ro OCTET STRING .1.3.6.1.4.1.485.3.7.1.1.1.3 |
deviceStatusThe status of the device.
To change (write) status of a device, enable, disable,
restart or enable all may be set.
Valid Return (read) status are enable(d), disable(d),
or failed (d).
Commands:
An enable command will attempt to bring up the device.
An enable all command will perform the same function
as enable, since there are no sub elements on a device.
A disable command will disable the device.
Status:
Enable(d) indicates the device is enabled and running.
Disable(d) indicates the device has been disabled.
Failed (d) indicates the device is enabled and not
Running.rw Enumeration .1.3.6.1.4.1.485.3.7.1.1.1.4 |
deviceControlFailureCodeThis entry contains the failure codes if the
associated device is in the failed state.ro OCTET STRING .1.3.6.1.4.1.485.3.7.1.1.1.5 |
deviceBSCGroup OBJECT IDENTIFIER .1.3.6.1.4.1.485.3.7.2 |
deviceConfigTableA list of device entries. SEQUENCE OF DeviceConfigEntry .1.3.6.1.4.1.485.3.7.2.1 |
deviceConfigEntryThis entry contains information about
a given device. The entry is indexed by the
port number, CU index, and device. DeviceConfigEntry .1.3.6.1.4.1.485.3.7.2.1.1 |
deviceConfigLineIndexThe port number for which the line (CU)is configured
(line level).ro INTEGER .1.3.6.1.4.1.485.3.7.2.1.1.1 |
deviceConfigCUIndexThe CU index which this device is configured on
(CU level).ro INTEGER .1.3.6.1.4.1.485.3.7.2.1.1.2 |
deviceConfigAddressThe device address in the legal range of BSC poll
addresses (device level).ro OCTET STRING .1.3.6.1.4.1.485.3.7.2.1.1.3 |
deviceConfigTypeThe device type. The default value is crt.ro Enumeration .1.3.6.1.4.1.485.3.7.2.1.1.4 |
deviceStatsTableA table of device statistics information. SEQUENCE OF DeviceStatsEntry .1.3.6.1.4.1.485.3.7.2.2 |
deviceStatsEntryThis entry contains information about
a given device. The entry is indexed by the
port number, CU index, and device. DeviceStatsEntry .1.3.6.1.4.1.485.3.7.2.2.1 |
bscDeviceLineIndexThe port number for which the line (CU)is configured
(line level).ro INTEGER .1.3.6.1.4.1.485.3.7.2.2.1.1 |
bscDeviceCUIndexThe CU index which this device is configured on
(CU level).ro INTEGER .1.3.6.1.4.1.485.3.7.2.2.1.2 |
bscDeviceAddressThe device address in the legal range of BSC poll
addresses (device level).ro OCTET STRING .1.3.6.1.4.1.485.3.7.2.2.1.3 |
bscDeviceInTransactionsThe number of device receiving transactions.ro Counter .1.3.6.1.4.1.485.3.7.2.2.1.4 |
bscDeviceOutTransactionsThe number of device transmitting transactions.ro Counter .1.3.6.1.4.1.485.3.7.2.2.1.5 |
bscDeviceSumCountThe device sum count.ro Counter .1.3.6.1.4.1.485.3.7.2.2.1.6 |
bscDeviceResponseDelaySumThe device sum count.ro Counter .1.3.6.1.4.1.485.3.7.2.2.1.7 |
bscDeviceResponseDelaySqSumThe device sum count.ro Counter .1.3.6.1.4.1.485.3.7.2.2.1.8 |