SUPERMICRO-HEALTH-MIB
AI MIB Summary
The SUPERMICRO-HEALTH-MIB enables Supermicro server hardware monitoring via SNMP to track critical system health metrics including chassis intrusion status, fan speeds, voltage rails, and CPU temperature thresholds.
MIB module for monitoring health information
Main OID:
smHealthMIB.1.3.6.1.4.1.10876.2.1
20
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
20 total| Object Name |
|---|
smHealthMIBMIB module for monitoring health information MODULE-IDENTITY .1.3.6.1.4.1.10876.2.1 |
smHealthObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10876.2.1.1 |
smHealthMonitorTableA table of health monitoring entries. SEQUENCE OF SMHealthMonitorEntry .1.3.6.1.4.1.10876.2.1.1.1 |
smHealthMonitorEntryAn entry in the health monitoring table. Entries cannot be created or deleted via SNMP operations. SMHealthMonitorEntry .1.3.6.1.4.1.10876.2.1.1.1.1 |
smHealthMonitorIndexThe unique value which identifies this Monitor device. Integer32 .1.3.6.1.4.1.10876.2.1.1.1.1.1 |
smHealthMonitorNameA textual full name assigned to the Monitor device. This object is suitable for output to a human operator.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10876.2.1.1.1.1.2 |
smHealthMonitorTypeIdentifies this Monitor device type.ro SMHealthInfoTypes .1.3.6.1.4.1.10876.2.1.1.1.1.3 |
smHealthMonitorReadingIndicates the value from the Monitor device that are currently in use on the managed device. FAN reading is in unit of RPM, Voltage reading is in unit of mV, Temperture reading is in unit of degree Cro Integer32 .1.3.6.1.4.1.10876.2.1.1.1.1.4 |
smHealthMonitorHighLimitIndicates the value for the High limitation for the Monitor device that are currently in use on the managed device. Apply to Temperature and Voltage deivces only. Voltage limit is in unit of mV, Temperture limit is in unit of degree Crw Integer32 .1.3.6.1.4.1.10876.2.1.1.1.1.5 |
smHealthMonitorLowLimitIndicates the value for the Low limitation for the Monitor device that are currently in use on the managed device. FAN limit is in unit of RPM, Voltage limit is in unit of mV, Temperture limit is in unit of degree Crw Integer32 .1.3.6.1.4.1.10876.2.1.1.1.1.6 |
smHealthMonitorMaxReadingIndicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device. FAN reading is in unit of RPM, Voltage reading is in unit of mV, Temperture reading is in unit of degree Cro Integer32 .1.3.6.1.4.1.10876.2.1.1.1.1.7 |
smHealthMonitorMinReadingIndicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device. FAN reading is in unit of RPM, Voltage reading is in unit of mV, Temperture reading is in unit of degree Cro Integer32 .1.3.6.1.4.1.10876.2.1.1.1.1.8 |
smHealthMonitorDivisorIndicates the value for the Divisor for the Fan device that are currently in use on the managed device. Apply to Fan devices only.rw Integer32 .1.3.6.1.4.1.10876.2.1.1.1.1.9 |
smHealthMonitorMonitorIndicates the monitoring status for the Fan device that are currently in use on the managed device. 1 = monitor, 2=do not monitorrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.10876.2.1.1.1.1.10 |
smHealthNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.10876.2.1.2 |
smHealthConformance OBJECT IDENTIFIER .1.3.6.1.4.1.10876.2.1.3 |
smHealthCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.10876.2.1.3.1 |
smHealthComplianceThe compliance statement for entities which implement the Supermicro Health Monitoring MIB Unknown .1.3.6.1.4.1.10876.2.1.3.1.1 |
smHealthGroups OBJECT IDENTIFIER .1.3.6.1.4.1.10876.2.1.3.2 |
smHealthMonitorGroupA collection of objects providing Monitor devices. Unknown .1.3.6.1.4.1.10876.2.1.3.2.1 |