STORMSHIELD-HA-MIB
The STORMSHIELD-HA-MIB facilitates the monitoring and management of High Availability cluster states, node synchronization, and failover events for Stormshield security appliances. It exposes specific metrics regarding cluster topology, active/standby status, and heartbeat connectivity to ensure continuous service availability.
Imported Objects
Objects
38 total| Object Name |
|---|
snsHAstormshield HA cluster MODULE-IDENTITY .1.3.6.1.4.1.11256.1.11 |
IMPORTSstormshield HA cluster Unknown .1.3.6.1.4.1.11256.1.11 |
snsNbNodeNumber of firewalls in the HA clusterro Integer32 .1.3.6.1.4.1.11256.1.11.1 |
snsNbDeadNodeNumber of firewalls registered in the HA cluster but not replyingro Integer32 .1.3.6.1.4.1.11256.1.11.2 |
snsNbActiveNodeNumber of active firewallsro Integer32 .1.3.6.1.4.1.11256.1.11.3 |
snsNbHALinksNumber of ethernet links used for HA communicationro Integer32 .1.3.6.1.4.1.11256.1.11.5 |
snsNbFaultyHALinksNumber of faulty HA linksro Integer32 .1.3.6.1.4.1.11256.1.11.6 |
snsNodeTableFirewalls part of the HA cluster SEQUENCE OF SnsNode .1.3.6.1.4.1.11256.1.11.7 |
snsNodeHA node SnsNode .1.3.6.1.4.1.11256.1.11.7.1 |
snsNodeIndexIndex of each line in table Integer32 .1.3.6.1.4.1.11256.1.11.7.1.1 |
snsFwSerialFirewall serialro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.2 |
snsOnlineFirewall is onlinero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.3 |
snsModelFirewall modelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.4 |
snsVersionFirewall firmware versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.5 |
snsHALicenceHA Licencero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.6 |
snsHAQualityHA Qualityro Integer32 .1.3.6.1.4.1.11256.1.11.7.1.7 |
snsHAPriorityHA Priorityro Integer32 .1.3.6.1.4.1.11256.1.11.7.1.8 |
snsHAStatusForcedHA status forced (-2 : Unknown forced status,
-1 : No peer found, 0 : No forced status,
1 : Forced active, 2 : Forced passive)ro Integer32 .1.3.6.1.4.1.11256.1.11.7.1.9 |
snsHAActiveIs the firewall active ?ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.10 |
snsUptimeFirewall uptimero Integer32 .1.3.6.1.4.1.11256.1.11.7.1.11 |
snsHASyncStatusFirewall configuration synchronization status ?
(1: Synced, 0: Not synced, -1: Unknown / Error)ro Integer32 .1.3.6.1.4.1.11256.1.11.8 |
snsHAFwAdminRevisonFirewall Admin Revisionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.9 |
snsNodePowerSupplyTablePower supply status of Firewalls SEQUENCE OF SnsNodePowerSupplyEntry .1.3.6.1.4.1.11256.1.11.10 |
snsNodePowerSupplyEntryPower supply information SnsNodePowerSupplyEntry .1.3.6.1.4.1.11256.1.11.10.1 |
snsNodePowerSupplyIndexIndex of each line in table Integer32 .1.3.6.1.4.1.11256.1.11.10.1.1 |
snsNodePowerSupplyPoweredPower supply is powered by electricity ?ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.10.1.2 |
snsNodeDiskTableDisks status of Firewalls SEQUENCE OF SnsNodeDiskEntry .1.3.6.1.4.1.11256.1.11.11 |
snsNodeDiskEntryDisk information SnsNodeDiskEntry .1.3.6.1.4.1.11256.1.11.11.1 |
snsNodeDiskIndexIndex of each disk in table Integer32 .1.3.6.1.4.1.11256.1.11.11.1.1 |
snsNodeDiskNameMount point namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.2 |
snsNodeDiskSmartResultResult of the smart infos testsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.3 |
snsNodeDiskIsRaidIs the disk a member of a RAID arrayro Integer32 .1.3.6.1.4.1.11256.1.11.11.1.4 |
snsNodeDiskRaidStatusRAID Statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.5 |
snsNodeDiskPositionDisk Positionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.6 |
snsNodeCpuTableCpus status of Firewalls SEQUENCE OF SnsNodeCpuEntry .1.3.6.1.4.1.11256.1.11.12 |
snsNodeCpuEntryCPU information SnsNodeCpuEntry .1.3.6.1.4.1.11256.1.11.12.1 |
snsNodeCpuIndexIndex of each cpu in table Integer32 .1.3.6.1.4.1.11256.1.11.12.1.1 |
snsNodeCpuTempTemperature in Celsius degreero Integer32 .1.3.6.1.4.1.11256.1.11.12.1.2 |
More MIBs from Netasq
Browse all NetasqMIBs →The STORMSHIELD-ASQ-STATS-MIB provides SNMP access to real-time performance counters and statistical data for Stormshield Application Security Gateway (ASQ) appliances, specifically tracking application-layer traffic volumes, session states, and protocol-specific anomaly metrics. This module enables network operations to monitor ASQ throughput, connection rates, and security event logs for capacity planning and intrusion detection analysis.
The STORMSHIELD-IF-MIB provides SNMP access to interface-level statistics and operational states for Stormshield network security appliances, including firewall and UTM devices. It enables the monitoring of standard interface metrics such as octet counts, packet rates, error counters, and link status to facilitate traffic analysis and fault detection.
Standard SNMP MIB module defining data structures for NETASQ-IF-MIB.
The STORMSHIELD-MODEL-MIB exposes the specific hardware model identifier of Stormshield network security appliances to facilitate device inventory management and automated configuration validation. This module enables monitoring systems to distinguish between distinct firewall or gateway variants for accurate policy application and firmware compatibility checks.
SNMP MIB module
This deprecated module provided SNMP trap definitions for Stormshield firewall and security gateway alarm events, including intrusion detection alerts, interface status changes, and system resource thresholds. Its functionality has been superseded by current MIBs within the Stormshield ecosystem, rendering it obsolete for active monitoring deployments.