STORMSHIELD-HA-MIB
AI MIB Summary
The STORMSHIELD-HA-MIB facilitates the monitoring and management of High Availability cluster states, node synchronization, and failover events for Stormshield security appliances. It exposes specific metrics regarding cluster topology, active/standby status, and heartbeat connectivity to ensure continuous service availability.
stormshield HA cluster
Main OID:
snsHA.1.3.6.1.4.1.11256.1.11
38
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
38 total| Object Name |
|---|
snsHAstormshield HA cluster MODULE-IDENTITY .1.3.6.1.4.1.11256.1.11 |
IMPORTSstormshield HA cluster Unknown .1.3.6.1.4.1.11256.1.11 |
snsNbNodeNumber of firewalls in the HA clusterro Integer32 .1.3.6.1.4.1.11256.1.11.1 |
snsNbDeadNodeNumber of firewalls registered in the HA cluster but not replyingro Integer32 .1.3.6.1.4.1.11256.1.11.2 |
snsNbActiveNodeNumber of active firewallsro Integer32 .1.3.6.1.4.1.11256.1.11.3 |
snsNbHALinksNumber of ethernet links used for HA communicationro Integer32 .1.3.6.1.4.1.11256.1.11.5 |
snsNbFaultyHALinksNumber of faulty HA linksro Integer32 .1.3.6.1.4.1.11256.1.11.6 |
snsNodeTableFirewalls part of the HA cluster SEQUENCE OF SnsNode .1.3.6.1.4.1.11256.1.11.7 |
snsNodeHA node SnsNode .1.3.6.1.4.1.11256.1.11.7.1 |
snsNodeIndexIndex of each line in table Integer32 .1.3.6.1.4.1.11256.1.11.7.1.1 |
snsFwSerialFirewall serialro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.2 |
snsOnlineFirewall is onlinero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.3 |
snsModelFirewall modelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.4 |
snsVersionFirewall firmware versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.5 |
snsHALicenceHA Licencero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.6 |
snsHAQualityHA Qualityro Integer32 .1.3.6.1.4.1.11256.1.11.7.1.7 |
snsHAPriorityHA Priorityro Integer32 .1.3.6.1.4.1.11256.1.11.7.1.8 |
snsHAStatusForcedHA status forced (-2 : Unknown forced status,
-1 : No peer found, 0 : No forced status,
1 : Forced active, 2 : Forced passive)ro Integer32 .1.3.6.1.4.1.11256.1.11.7.1.9 |
snsHAActiveIs the firewall active ?ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.7.1.10 |
snsUptimeFirewall uptimero Integer32 .1.3.6.1.4.1.11256.1.11.7.1.11 |
snsHASyncStatusFirewall configuration synchronization status ?
(1: Synced, 0: Not synced, -1: Unknown / Error)ro Integer32 .1.3.6.1.4.1.11256.1.11.8 |
snsHAFwAdminRevisonFirewall Admin Revisionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.9 |
snsNodePowerSupplyTablePower supply status of Firewalls SEQUENCE OF SnsNodePowerSupplyEntry .1.3.6.1.4.1.11256.1.11.10 |
snsNodePowerSupplyEntryPower supply information SnsNodePowerSupplyEntry .1.3.6.1.4.1.11256.1.11.10.1 |
snsNodePowerSupplyIndexIndex of each line in table Integer32 .1.3.6.1.4.1.11256.1.11.10.1.1 |
snsNodePowerSupplyPoweredPower supply is powered by electricity ?ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.10.1.2 |
snsNodeDiskTableDisks status of Firewalls SEQUENCE OF SnsNodeDiskEntry .1.3.6.1.4.1.11256.1.11.11 |
snsNodeDiskEntryDisk information SnsNodeDiskEntry .1.3.6.1.4.1.11256.1.11.11.1 |
snsNodeDiskIndexIndex of each disk in table Integer32 .1.3.6.1.4.1.11256.1.11.11.1.1 |
snsNodeDiskNameMount point namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.2 |
snsNodeDiskSmartResultResult of the smart infos testsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.3 |
snsNodeDiskIsRaidIs the disk a member of a RAID arrayro Integer32 .1.3.6.1.4.1.11256.1.11.11.1.4 |
snsNodeDiskRaidStatusRAID Statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.5 |
snsNodeDiskPositionDisk Positionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11256.1.11.11.1.6 |
snsNodeCpuTableCpus status of Firewalls SEQUENCE OF SnsNodeCpuEntry .1.3.6.1.4.1.11256.1.11.12 |
snsNodeCpuEntryCPU information SnsNodeCpuEntry .1.3.6.1.4.1.11256.1.11.12.1 |
snsNodeCpuIndexIndex of each cpu in table Integer32 .1.3.6.1.4.1.11256.1.11.12.1.1 |
snsNodeCpuTempTemperature in Celsius degreero Integer32 .1.3.6.1.4.1.11256.1.11.12.1.2 |