SLE-RED-MIB
The SLE-RED-MIB module monitors and manages active/standby redundancy states and failover events for SLE (Secure Link Edge) appliances. It provides visibility into the operational status of redundant control planes, enabling administrators to verify synchronization health and detect state transitions between primary and backup nodes.
Imported Objects
Objects
26 total| Object Name |
|---|
sleRedThis MIB contains information to support active/standby control redundancy. MODULE-IDENTITY .1.3.6.1.4.1.6296.101.22 |
sleRedBase OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.22.1 |
sleRedInfo OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.22.1.1 |
sleRedActiveBoardIndication of the actual service board identifier. Regardless of redundancy mode, it has actual service board id.ro SleRedBoardIdType .1.3.6.1.4.1.6296.101.22.1.1.1 |
sleRedModeIf two SFUs are installed in the system, it works as redundant mode. Otherwise, it works as standalone mode.ro SleRedModeType .1.3.6.1.4.1.6296.101.22.1.1.2 |
sleRedFaultCrashActionIf any software module is crashed, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.ro SleRedFaultActionType .1.3.6.1.4.1.6296.101.22.1.1.3 |
sleRedFaultTimeoutActionIf any software module doesn't respond for healthcheck messages for the certain time, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.ro SleRedFaultActionType .1.3.6.1.4.1.6296.101.22.1.1.4 |
sleRedFaultTimeoutHealthcheck timeout. If a software module doesn't respond for the given time, it is regarded as a timed-out module. (Unit: second, default is '5')ro INTEGER .1.3.6.1.4.1.6296.101.22.1.1.5 |
sleRedActivePrevStatePrevious state of active board.ro Enumeration .1.3.6.1.4.1.6296.101.22.1.1.6 |
sleRedActiveCurrStateCurrent state of active board.ro Enumeration .1.3.6.1.4.1.6296.101.22.1.1.7 |
sleRedControl OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.22.1.2 |
sleRedControlRequestSystem commands related to control redundancy function.rw Enumeration .1.3.6.1.4.1.6296.101.22.1.2.1 |
sleRedControlStatusThe status of a user command.ro SleControlStatusType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.22.1.2.2 |
sleRedControlTimerThe maximum wait time for the manager for a long running user command.rw Gauge32 .1.3.6.1.4.1.6296.101.22.1.2.3 |
sleRedControlTimeStampThe time stamp of the last command (end of command).ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.22.1.2.4 |
sleRedControlReqResultThe result of the last user command.ro SleControlRequestResultType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.22.1.2.5 |
sleRedControlReloadOSA mate board is reloaded with the given os. If 'default' is given, the board is reloaded with 'default' OS.rw SleRedReloadOSType .1.3.6.1.4.1.6296.101.22.1.2.6 |
sleRedControlFaultCrashActionIf any software module is crashed, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.rw SleRedFaultActionType .1.3.6.1.4.1.6296.101.22.1.2.7 |
sleRedControlFaultTimeoutActionIf any software module doesn't respond for healthcheck messages for the certain time, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.rw SleRedFaultActionType .1.3.6.1.4.1.6296.101.22.1.2.8 |
sleRedControlFaultTimeoutHealthcheck timeout. If a software module doesn't respond for the given time, it is regarded as a timed-out module. (Unit: second, default is '5')rw INTEGER .1.3.6.1.4.1.6296.101.22.1.2.9 |
sleRedNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.22.1.3 |
sleRedMateReloadRequestedA new active SFU indication NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.22.1.3.1 |
sleRedSwitchoverRequestedThe system redundancy mode has been changed. A standby board is pluged out or in. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.22.1.3.2 |
sleRedFaultMonitorChangedFault monitor configuration has been changed. NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.22.1.3.3 |
sleRedGroupDescription. Unknown .1.3.6.1.4.1.6296.101.22.2 |
sleRedNotificationGroupDescription. Unknown .1.3.6.1.4.1.6296.101.22.3 |
More MIBs from Dasan
Browse all DasanMIBs →SNMP MIB module
The SLE-FAULTMGMT-MIB module provides the SNMP interface for monitoring and managing alarm states, fault conditions, and logical entity health within SLE (Service Level Enforcement) network devices. It enables the retrieval of specific fault metrics, including alarm severity levels, timestamps, and the operational status of logical service entities to facilitate automated incident detection and remediation.
SNMP MIB module
Standard SNMP MIB module defining data structures for SLEV2-MULTICAST-MIB.
SNMP MIB module
SNMP MIB module