Home/Catalog/SLE-RED-MIB

SLE-RED-MIB

AI MIB Summary

The SLE-RED-MIB module monitors and manages active/standby redundancy states and failover events for SLE (Secure Link Edge) appliances. It provides visibility into the operational status of redundant control planes, enabling administrators to verify synchronization health and detect state transitions between primary and backup nodes.

This MIB contains information to support active/standby control redundancy.
Main OID:
sleRed.1.3.6.1.4.1.6296.101.22
26
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

26 total
Object Name
sleRedThis MIB contains information to support active/standby control redundancy.
MODULE-IDENTITY
.1.3.6.1.4.1.6296.101.22
sleRedBase
OBJECT IDENTIFIER
.1.3.6.1.4.1.6296.101.22.1
sleRedInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.6296.101.22.1.1
sleRedActiveBoardIndication of the actual service board identifier. Regardless of redundancy mode, it has actual service board id.ro
SleRedBoardIdType
.1.3.6.1.4.1.6296.101.22.1.1.1
sleRedModeIf two SFUs are installed in the system, it works as redundant mode. Otherwise, it works as standalone mode.ro
SleRedModeType
.1.3.6.1.4.1.6296.101.22.1.1.2
sleRedFaultCrashActionIf any software module is crashed, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.ro
SleRedFaultActionType
.1.3.6.1.4.1.6296.101.22.1.1.3
sleRedFaultTimeoutActionIf any software module doesn't respond for healthcheck messages for the certain time, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.ro
SleRedFaultActionType
.1.3.6.1.4.1.6296.101.22.1.1.4
sleRedFaultTimeoutHealthcheck timeout. If a software module doesn't respond for the given time, it is regarded as a timed-out module. (Unit: second, default is '5')ro
INTEGER
.1.3.6.1.4.1.6296.101.22.1.1.5
sleRedActivePrevStatePrevious state of active board.ro
Enumeration
.1.3.6.1.4.1.6296.101.22.1.1.6
sleRedActiveCurrStateCurrent state of active board.ro
Enumeration
.1.3.6.1.4.1.6296.101.22.1.1.7
sleRedControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.6296.101.22.1.2
sleRedControlRequestSystem commands related to control redundancy function.rw
Enumeration
.1.3.6.1.4.1.6296.101.22.1.2.1
sleRedControlStatusThe status of a user command.ro
SleControlStatusType (SLE-TC-MIB)
.1.3.6.1.4.1.6296.101.22.1.2.2
sleRedControlTimerThe maximum wait time for the manager for a long running user command.rw
Gauge32
.1.3.6.1.4.1.6296.101.22.1.2.3
sleRedControlTimeStampThe time stamp of the last command (end of command).ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.6296.101.22.1.2.4
sleRedControlReqResultThe result of the last user command.ro
SleControlRequestResultType (SLE-TC-MIB)
.1.3.6.1.4.1.6296.101.22.1.2.5
sleRedControlReloadOSA mate board is reloaded with the given os. If 'default' is given, the board is reloaded with 'default' OS.rw
SleRedReloadOSType
.1.3.6.1.4.1.6296.101.22.1.2.6
sleRedControlFaultCrashActionIf any software module is crashed, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.rw
SleRedFaultActionType
.1.3.6.1.4.1.6296.101.22.1.2.7
sleRedControlFaultTimeoutActionIf any software module doesn't respond for healthcheck messages for the certain time, the given action is taken. For 'switchover' action, if the board is active and a standby board is available, 'switchover' is carried out. If a standby board is not available, just warning message is left. If it is a standby board, 'reset' is carried out.rw
SleRedFaultActionType
.1.3.6.1.4.1.6296.101.22.1.2.8
sleRedControlFaultTimeoutHealthcheck timeout. If a software module doesn't respond for the given time, it is regarded as a timed-out module. (Unit: second, default is '5')rw
INTEGER
.1.3.6.1.4.1.6296.101.22.1.2.9
sleRedNotification
OBJECT IDENTIFIER
.1.3.6.1.4.1.6296.101.22.1.3
sleRedMateReloadRequestedA new active SFU indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.6296.101.22.1.3.1
sleRedSwitchoverRequestedThe system redundancy mode has been changed. A standby board is pluged out or in.
NOTIFICATION-TYPE
.1.3.6.1.4.1.6296.101.22.1.3.2
sleRedFaultMonitorChangedFault monitor configuration has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.6296.101.22.1.3.3
sleRedGroupDescription.
Unknown
.1.3.6.1.4.1.6296.101.22.2
sleRedNotificationGroupDescription.
Unknown
.1.3.6.1.4.1.6296.101.22.3
SLE-RED-MIB - SNMP MIB Reference | MIBs Explorer