SLE-MPLS-TP-PRO-IF-MIB
Copyright (c) 2012 IETF Trust and the persons identified as the document authors. All rights reserved. This MIB module contains generic object definitions for MPLS Traffic Engineering in transport networks.
Main OID:
sleMplsTpNode.1.3.6.1.4.1.6296.101.16.13
15
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
15 total| Object Name |
|---|
sleMplsSLE MPLS. OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.16 |
sleMplsTpNodeCopyright (c) 2012 IETF Trust and the persons identified as the document authors. All rights reserved. This MIB module contains generic object definitions for MPLS Traffic Engineering in transport networks. MODULE-IDENTITY .1.3.6.1.4.1.6296.101.16.13 |
sleMplsTpProIf OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.16.13.2 |
sleMplsTpProIfInfoTable SEQUENCE OF SleMplsTpProIfInfoEntry .1.3.6.1.4.1.6296.101.16.13.2.1 |
sleMplsTpProIfInfoEntry SleMplsTpProIfInfoEntry .1.3.6.1.4.1.6296.101.16.13.2.1.1 |
sleMplsTPProIfInfoIfIndexThis object is used in accommodating the bigger size Global_Node_ID and/or ICC with lower size LSR identifier in order to index the mplsTunnelTable. The Local Identifier is configured between 1 and 16777215, as valid IP address range starts from 16777216(01.00.00.00). This range is chosen to identify the mplsTunnelTable's Ingress/Egress LSR-id is IP address or Local identifier, if the configured range is not IP address, administrator is expected to retrieve the complete information (Global_Node_ID or ICC) from mplsTunnelExtNodeConfigTable. This way, existing mplsTunnelTable is reused for bidirectional tunnel extensions for MPLS based transport networks. This Local Identifier allows the administrator to assign a unique identifier to map Global_Node_ID and/or ICC. Unsigned32 .1.3.6.1.4.1.6296.101.16.13.2.1.1.1 |
sleMplsTPProIfInfoIpAddrro IpAddress .1.3.6.1.4.1.6296.101.16.13.2.1.1.2 |
sleMplsTpProIfControl OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.16.13.2.2 |
sleMplsTpProIfControlRequestThis object holds the possible read-write columns that can be modified in the TunnelExtNodeConfigTable table. For each read-write column of TunnelExtNodeConfigTable table, a Set Operation control value is added in this object.rw Enumeration .1.3.6.1.4.1.6296.101.16.13.2.2.1 |
sleMplsTpProIfControlStatusThis object displays the status of the configuration done.ro SleControlStatusType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.16.13.2.2.2 |
sleMplsTpProIfControlTimerThis object is based on the SLE style where a timer is configured for every control table.rw Gauge32 .1.3.6.1.4.1.6296.101.16.13.2.2.3 |
sleMplsTpProIfControlTimestampThis object specifies the time at which the configuration is done.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.16.13.2.2.4 |
sleMplsTpProIfControlReqResultThe standard result of the SET operation is stored here.ro SleControlRequestResultType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.16.13.2.2.5 |
sleMplsTpProIfControlIfIndexrw Unsigned32 .1.3.6.1.4.1.6296.101.16.13.2.2.6 |
sleMplsTpProIfControlIpAddrThis object indicates the Global Operator Identifier.rw IpAddress .1.3.6.1.4.1.6296.101.16.13.2.2.7 |