SLE-AM-MIB
AI MIB Summary
The SLE-AM-MIB module facilitates the monitoring and management of alarm states, severity levels, and event notifications within the Alcatel-Lucent (now Nokia) Service Level Enforcement (SLE) platform. It enables network operators to retrieve real-time alarm data for troubleshooting service disruptions and maintaining system availability through standard SNMP queries.
This MIB contains all needed informations about Alarm Manager.
Main OID:
sleAlarmMgr.1.3.6.1.4.1.6296.101.15
107
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
107 total| Object Name |
|---|
sleAlarmMgrThis MIB contains all needed informations about Alarm Manager. MODULE-IDENTITY .1.3.6.1.4.1.6296.101.15 |
sleAMAlarmTrapNeIduse for NE idendification when alarm(or event) trap system MAC addressro OCTET STRING .1.3.6.1.4.1.6296.101.15.1 |
sleAMConfigBase OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.2 |
sleAMConfigTableThis table is the class Master Alarm table. It gets populated when system init is done. And it contains all the class alarms supported for the device SEQUENCE OF SleAMConfigEntry .1.3.6.1.4.1.6296.101.15.2.1 |
sleAMConfigEntry SleAMConfigEntry .1.3.6.1.4.1.6296.101.15.2.1.1 |
sleAMConfigAlarmClassIdClass ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-clientro AMAlarmClassId .1.3.6.1.4.1.6296.101.15.2.1.1.1 |
sleAMConfigAlarmIdAlarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-clientro AMAlarmId .1.3.6.1.4.1.6296.101.15.2.1.1.2 |
sleAMConfigAlarmNameAlarm Name stringrw OCTET STRING .1.3.6.1.4.1.6296.101.15.2.1.1.3 |
sleAMConfigAlarmSeverityAlarm severity: The default severity is pre-defined by each Alarm manager clients critical(1), major(2), minor(3), warning(4), intermediate(5),ro AMAlarmSeverity .1.3.6.1.4.1.6296.101.15.2.1.1.4 |
sleAMConfigAlarmEnableStateAlarm Trap State. Based on the trap state, the alarm will be notified to NMS. If the TRAP STATE is enabled then the alarm will be notified else wont be notified. enable (1) disabe (0)ro AMTrapState .1.3.6.1.4.1.6296.101.15.2.1.1.5 |
sleAMConfigAlarmRaiseGuardTimeAlarm raise Soaking time. When any alarm is raised, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)ro AMAlarmGuardTime .1.3.6.1.4.1.6296.101.15.2.1.1.6 |
sleAMConfigAlarmClearGuardTimeAlarm clear Soaking time. When any alarm is cleared, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)ro AMAlarmGuardTime .1.3.6.1.4.1.6296.101.15.2.1.1.7 |
sleAMConfigAlarmLedAlarm led configuration. Determinde led operate or not, when alarms occur. off(0): led not operate on(1) : led operaterw Enumeration .1.3.6.1.4.1.6296.101.15.2.1.1.8 |
sleAMConfigSpecificIdAlarm Configuration specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmIDrw Integer32 .1.3.6.1.4.1.6296.101.15.2.1.1.9 |
sleAMConfigControl OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.2.2 |
sleAMConfigControlRequestThe configuration commands, and user can configure functions via setting this entry as proper value.rw Enumeration .1.3.6.1.4.1.6296.101.15.2.2.1 |
sleAMConfigControlStatusstatus of user command. User have to check this value as .busy. or .idle. before do setRequest.ro SleControlStatusType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.2.2.2 |
sleAMConfigControlTimerthe wait-time until setRequest end. In case of short-time command, this value is 0rw Gauge32 .1.3.6.1.4.1.6296.101.15.2.2.3 |
sleAMConfigControlTimeStampthe time stamp of the last command. (don.t care)ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.15.2.2.4 |
sleAMConfigControlReqResultResult of the last command.ro SleControlRequestResultType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.2.2.5 |
sleAMConfigControlAlarmClassIdAlarm Manager Class IDrw AMAlarmClassId .1.3.6.1.4.1.6296.101.15.2.2.6 |
sleAMConfigControlAlarmIdAlarm Manager Alarm Indexrw AMAlarmId .1.3.6.1.4.1.6296.101.15.2.2.7 |
sleAMConfigControlSeverityAlarm Class Severity critical(1), major(2), minor(3), warning(4), ignore(5), default(6)rw AMAlarmSeverity .1.3.6.1.4.1.6296.101.15.2.2.8 |
sleAMConfigControlEnableStateAlarm Trap State. Based on the trap state, the alarm will be notified to NMS. If the TRAP STATE is enabled then the alarm will be notified else wont be notified. enable (1) disabe (0)rw AMTrapState .1.3.6.1.4.1.6296.101.15.2.2.9 |
sleAMConfigControlRaiseGuardTimeAlarm Raise Soaking time. When any alarm is raised, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)rw AMAlarmGuardTime .1.3.6.1.4.1.6296.101.15.2.2.10 |
sleAMConfigControlClearGuardTimeAlarm clear Soaking time. When any alarm is cleared, this attribute specifies how much time the alarm should be soaked before notifying to Alarm manager range:1 ~ 30, (if '0', no soaking time)rw AMAlarmGuardTime .1.3.6.1.4.1.6296.101.15.2.2.11 |
sleAMConfigControlLedAlarm led configuration. Determinde led operate or not, when alarms occur. off(0): led not operate on(1) : led operaterw Integer32 .1.3.6.1.4.1.6296.101.15.2.2.12 |
sleAMConfigNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.2.3 |
sleAMConfigSeverityChangedNotification for Alarm severity change NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.2.3.1 |
sleAMConfigEnableStateChangedNotification for Class Trap State change NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.2.3.2 |
sleAMConfigRaiseGuardTimeChangedNotification for Raise Soak time change NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.2.3.3 |
sleAMConfigClearGuardTimeChangedNotification for Clear Soak time change NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.2.3.4 |
sleAMConfigLedChangedNotification for Alarm led configuration change NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.2.3.5 |
sleAMCurrentBase OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.3 |
sleAMCurrentTableThis table contains the current active alarms for the Alarm Class. Each Row in this table gets populated when any Alarm is raised SEQUENCE OF SleAMCurrentEntry .1.3.6.1.4.1.6296.101.15.3.1 |
sleAMCurrentEntry SleAMCurrentEntry .1.3.6.1.4.1.6296.101.15.3.1.1 |
sleAMCurrentSeqIdalarm sequence id key of current alarm table it generated by alarm-manager automaticallyro Unsigned32 .1.3.6.1.4.1.6296.101.15.3.1.1.1 |
sleAMCurrentAlarmSourcealarm location infomation |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location valuero AMAlarmSrc .1.3.6.1.4.1.6296.101.15.3.1.1.2 |
sleAMCurrentAlarmClassIdClass ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-clientro AMAlarmClassId .1.3.6.1.4.1.6296.101.15.3.1.1.3 |
sleAMCurrentAlarmIdAlarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-clientro AMAlarmId .1.3.6.1.4.1.6296.101.15.3.1.1.4 |
sleAMCurrentAlarmStatusCurrent Alarm State: raised (1), masked(2)ro AlarmStatus .1.3.6.1.4.1.6296.101.15.3.1.1.5 |
sleAMCurrentAlarmSeverityCurrent Alarm Severity: critical(1), major(2), minor(3), warning(4)ro AMAlarmSeverity .1.3.6.1.4.1.6296.101.15.3.1.1.6 |
sleAMCurrentAlarmReasonreasion stringro AMAlarmReason .1.3.6.1.4.1.6296.101.15.3.1.1.7 |
sleAMCurrentTimeAndDateCurrent Alarm Time and Datero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.15.3.1.1.8 |
sleAMCurrentSpecificIdCurrent Alarm specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmIDrw INTEGER .1.3.6.1.4.1.6296.101.15.3.1.1.9 |
sleAMCurrentControl OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.3.2 |
sleAMCurrentControlRequestThe configuration commands, and user can configure functions via setting this entry as proper value. 1: all current alarm clear 2: current alarm clear by SeqId 3: current alarm clear by Source(location)rw Enumeration .1.3.6.1.4.1.6296.101.15.3.2.1 |
sleAMCurrentControlStatusstatus of user command. User have to check this value as .busy. or .idle. before do setRequest.ro SleControlStatusType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.3.2.2 |
sleAMCurrentControlTimerthe wait-time until setRequest end. In case of short-time command, this value is 0rw Gauge32 .1.3.6.1.4.1.6296.101.15.3.2.3 |
sleAMCurrentControlTimeStampthe time stamp of the last command. (don.t care)ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.15.3.2.4 |
sleAMCurrentControlReqResultResult of the last command.ro SleControlRequestResultType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.3.2.5 |
sleAMCurrentControlSeqIdcurrent alarmControl Sequence ID.(0, all mcurrent alarm cleared) Valid only if the sleAMHistoryControlRequest value is set to 2(alarmHistoryClearBySeqId).rw Unsigned32 .1.3.6.1.4.1.6296.101.15.3.2.6 |
sleAMCurrentControlSourcecurrent alarm clear location infomation |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location valuerw AMAlarmSrc .1.3.6.1.4.1.6296.101.15.3.2.7 |
sleAMCurrentNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.3.3 |
sleAMCurrentAlarmClearedNotification for current alarm clear NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.3.3.1 |
sleAlarmTrapAlarmNotify Alarm Raise/Clear TRAPS to NMS for each entry in the Table NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.3.3.2 |
sleAlarmTrapEventNotify Event Occur TRAPS to NMS for each entry in the Table NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.3.3.3 |
sleAMHistoryBase OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.4 |
sleAMHistoryTableThis Table is used to for keeping the Alarm History SEQUENCE OF SleAMHistoryEntry .1.3.6.1.4.1.6296.101.15.4.1 |
sleAMHistoryEntry SleAMHistoryEntry .1.3.6.1.4.1.6296.101.15.4.1.1 |
sleAMHistorySeqIdAlarm History Sequence ID. This sequence Id is maintained based on the TRAP sent.ro Unsigned32 .1.3.6.1.4.1.6296.101.15.4.1.1.1 |
sleAMHistoryAlarmSource|type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location valuero AMAlarmSrc .1.3.6.1.4.1.6296.101.15.4.1.1.2 |
sleAMHistoryAlarmClassIdClass ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-clientro AMAlarmClassId .1.3.6.1.4.1.6296.101.15.4.1.1.3 |
sleAMHistoryAlarmIdHistory Alarm ID Alarm ID starts from 1 to 65535 for the system. And these IDs are defined by alarm-clientro AMAlarmId .1.3.6.1.4.1.6296.101.15.4.1.1.4 |
sleAMHistoryAlarmStatusHistory Alarm State: cleared (0), raised (1), masked(2)ro AlarmStatus .1.3.6.1.4.1.6296.101.15.4.1.1.5 |
sleAMHistoryAlarmSeverityHistory alarm Severity critical(1), major(2), minor(3), warning(4)ro AMAlarmSeverity .1.3.6.1.4.1.6296.101.15.4.1.1.6 |
sleAMHistoryAlarmReasonHistory alarm Reason stringrw AMAlarmReason .1.3.6.1.4.1.6296.101.15.4.1.1.7 |
sleAMHistoryAlarmTimeDateHistory Alarm Time and Datero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.15.4.1.1.8 |
sleAMHistorySpecificIdAlarm History specific ID(4bytes) classId and alarmID are combinded with a specificID * 1st,2nd Bytes - ClassId * 3rd,4th bytes - alarmIDrw Integer32 .1.3.6.1.4.1.6296.101.15.4.1.1.9 |
sleAMHistoryControl OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.4.2 |
sleAMHistoryControlRequestThe configuration commands, and user can configure functions via setting this entry as proper value. clearAlarmHistory : clears the alarms from the History Table 1: all alarm history clear 2: alarm history clear by SeqId 3: alarm history clear by Source(location)rw Enumeration .1.3.6.1.4.1.6296.101.15.4.2.1 |
sleAMHistoryControlStatusstatus of user command. User have to check this value as .busy. or .idle. before do setRequest.ro SleControlStatusType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.4.2.2 |
sleAMHistoryControlTimerthe wait-time until setRequest end. In case of short-time command, this value is 0rw Gauge32 .1.3.6.1.4.1.6296.101.15.4.2.3 |
sleAMHistoryControlTimeStampthe time stamp of the last command. (don.t care)ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.15.4.2.4 |
sleAMHistoryControlReqResultResult of the last command.ro SleControlRequestResultType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.4.2.5 |
sleAMHistoryControSeqIdAlarm History Control Sequence ID. Specify cleared history alarm ID (0, all alarm history cleared)rw Unsigned32 .1.3.6.1.4.1.6296.101.15.4.2.6 |
sleAMHistoryControSourcealarm history clear location infomation Valid only if the sleAMHistoryControlRequest value is set to 3(alarmHistoryClearBySource). |type|length|value|type|length|value|.... type (1-byte) : alarm location type length(1-byte) : alarm location value length value (length-bytes) : alarm location valuerw AMAlarmSrc .1.3.6.1.4.1.6296.101.15.4.2.7 |
sleAMHistoryNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.4.3 |
sleAMHistoryAlarmClearedNotification for History Class cleared NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.4.3.1 |
sleAMAcoBase OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.5 |
sleAMAcoInfoEntry OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.5.1 |
sleAMAcoInfoACO control configuration acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut.ro AMAlarmAco .1.3.6.1.4.1.6296.101.15.5.1.1 |
sleAMAcoControl OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.5.2 |
sleAMAcoControlRequestThe configuration commands, and user can configure functions via setting this entry as proper value.rw Enumeration .1.3.6.1.4.1.6296.101.15.5.2.1 |
sleAMAcogControlStatusstatus of user command. User have to check this value as .busy. or .idle. before do setRequest.ro SleControlStatusType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.5.2.2 |
sleAMAcoControlTimerthe wait-time until setRequest end. In case of short-time command, this value is 0rw Gauge32 .1.3.6.1.4.1.6296.101.15.5.2.3 |
sleAMAcoControlTimeStampthe time stamp of the last command. (don.t care)ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.15.5.2.4 |
sleAMAcoControlReqResultResult of the last command.ro SleControlRequestResultType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.5.2.5 |
sleAMAcoControlSetACO control acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut.rw AMAlarmAco .1.3.6.1.4.1.6296.101.15.5.2.6 |
sleAMAcoNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.5.3 |
sleAMAcoChangedNotification for Alarm ACO configuration change NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.5.3.1 |
sleAMLedBase OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.6 |
sleAMLedTableThis table contains the LED status and configuration. SEQUENCE OF SleAMLedEntry .1.3.6.1.4.1.6296.101.15.6.1 |
sleAMLedEntry SleAMLedEntry .1.3.6.1.4.1.6296.101.15.6.1.1 |
sleAMLedSeverityLED Alarm Severity critical(1), major(2), minor(3),rw Enumeration .1.3.6.1.4.1.6296.101.15.6.1.1.1 |
sleAMLedSetACO control configuration acoOff(1) : buzzer operation enable. acoOn(2) : buzzer operation disable. acoOpr(3) : current buzzer cut.rw AMAlarmLed .1.3.6.1.4.1.6296.101.15.6.1.1.2 |
sleAMLedCountalarm count of the associated ledrw Integer32 .1.3.6.1.4.1.6296.101.15.6.1.1.3 |
sleAMLedControl OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.6.2 |
sleAMLedControlRequestThe configuration commands, and user can configure functions via setting this entry as proper value.rw Enumeration .1.3.6.1.4.1.6296.101.15.6.2.1 |
sleAMLedControlStatusstatus of user command. User have to check this value as .busy. or .idle. before do setRequest.ro SleControlStatusType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.6.2.2 |
sleAMLedControlTimerthe wait-time until setRequest end. In case of short-time command, this value is 0rw Gauge32 .1.3.6.1.4.1.6296.101.15.6.2.3 |
sleAMLedControlTimeStampthe time stamp of the last command. (don.t care)ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6296.101.15.6.2.4 |
sleAMLedControlReqResultResult of the last command.ro SleControlRequestResultType (SLE-TC-MIB) .1.3.6.1.4.1.6296.101.15.6.2.5 |
sleAMLedControlSeverityLED Alarm Severity critical(1), major(2), minor(3),rw Enumeration .1.3.6.1.4.1.6296.101.15.6.2.6 |
sleAMLedControlSetLED control configuration ledOff(1) : LED operation disable. ledOn(2) : LED operation enable. ledOpr(3) : current LED off.rw AMAlarmLed .1.3.6.1.4.1.6296.101.15.6.2.7 |
sleAMLedNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6296.101.15.6.3 |
sleAMLedChangedNotification for LED configuration change NOTIFICATION-TYPE .1.3.6.1.4.1.6296.101.15.6.3.1 |