SEI-SMI
The Enterprise Number for System Engineering International
Main OID:
sei.1.3.6.1.4.1.20364
27
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
27 total| Object Name |
|---|
seiThe Enterprise Number for System Engineering International MODULE-IDENTITY .1.3.6.1.4.1.20364 |
juiceBoxAllocatedPowerThresholdReachedThis trap is sent when the Allocated Power is greater than the percentage
threshold set juiceBoxMainAllocatedPowerThreshold. TRAP-TYPE .1.3.6.1.4.1.20364.0.10 |
juiceBoxPortStatusChangeThis trap will be sent anytime the status of a Juice Box port
changes. TRAP-TYPE .1.3.6.1.4.1.20364.0.20 |
juiceBoxPse OBJECT IDENTIFIER .1.3.6.1.4.1.20364.1 |
juiceBoxObjects OBJECT IDENTIFIER .1.3.6.1.4.1.20364.1.1 |
juiceBoxPortTableA table of objects that display and control the power
characteristics of an individual port on a Juice Box
Midspan Power Hub. Values of all read-write objects in
this table are persistent at restart/reboot. SEQUENCE OF JuiceBoxPortEntry .1.3.6.1.4.1.20364.1.1.1 |
juiceBoxPortEntryA set of objects that display and control the power
characteristics of a Juice Box Midspan Power Hub port. JuiceBoxPortEntry .1.3.6.1.4.1.20364.1.1.1.1 |
juiceBoxPortIndexThis variable uniquely identifies the port within
the Juice Box Midspan Power Hub. Integer32 .1.3.6.1.4.1.20364.1.1.1.1.1 |
juiceBoxPortDetectionSettingDescribes the type of PD detection performed by the port.
A value of disabled(1) means that no PD detection is performed. If a port
currently delivering power is set to disabled(1), power will be removed
from the port.
A value of ieee802.3afonly(2) means only PDs with valid signatures
as defined by ieee 802.3af will be detected and powered.
A value of ieee8023afandlegacy(3) means that PDs with 802.3af and legacy
signatures will be detected and powered.
A value of forcedon(4) means the port is powered without regard to detection status.
A setting of forcedon(4) is not persistent and must be re-asserted after restart/rebootrw Enumeration .1.3.6.1.4.1.20364.1.1.1.1.2 |
juiceBoxPortMaxPowerDescribes the maximum power setting for the port in watts.
This setting is used by to calculate Allocated Power.
It is only used if the port is classified as Class 0 or Legacy.rw Enumeration .1.3.6.1.4.1.20364.1.1.1.1.3 |
juiceBoxPortDescriptionA manager will set the value of this variable to indicate
the type of powered device that is connected to the port.
The default value supplied by the agent if no value has
ever been set is PORT x where x is the port numberrw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.20364.1.1.1.1.4 |
juiceBoxPortStatusDescribes the status of the port.
A value of disabled(1) means that juiceBoxPortDetectionSetting for the port
is set to disabled. No PD detection will be performed.
A value of deliveringPower(2) means the port is delivering power within
operational parameters.
A value of startupFault(3) means that port failed to power up properly.
A value of overCurrentFault(4) means the port current was greater than the
350mA maximum value specified by IEEE 802.3af.
A value of short(5) means an short circuit was discovered during PD detection.
A value of open(6) means an open circuit was discovered during PD detection.
A value of rsignatureHi(7) means a resistance greater than the valid signature
specified by IEEE 802.3af was discovered during PD detection.
A value of rsignatureLow(8) means a resistance less than the valid signature
specified by IEEE 802.3af was discovered during PD detection.
A value of invalidDetect(9) means an invalid signature as
specified by IEEE 802.3af was discovered during PD detection.
A value of disconnect(10) means that the port current was less than the
10mA mininum value specified by IEEE 802.3af required to maintain power.
A value of powerup(12) means the port is in the process of being powered.
A value of overPowerWarning(13) means the port is delivering power greater
than the maximum value for its Class or the value set with juiceBoxPortMaxPower.
A value of overPowerFault(14) means the port was shut down because the power delivered
was at least 1 Watt greater than the maximum value for its Class or the value set
with juiceBoxPortMaxPower.
A value of insufficientPower(15) means the port could not be powered because
there is insuffiecent power capability remaining to fully power the port.ro Enumeration .1.3.6.1.4.1.20364.1.1.1.1.5 |
juiceBoxPortClassificationsClassification is a way to identify a Powered Device according to
its power consumption.
The meaning of the classification labels is defined in the
IEEE specification.
This variable is valid only while a PD is being powered,
that is, while the attribute juiceBoxPortStatus is reporting
the enumeration deliveringPower or overpowerWarning.ro Enumeration .1.3.6.1.4.1.20364.1.1.1.1.6 |
juiceBoxPortPowerDeliveredMeasured usage power of port expressed in milliWatts.
This variable is valid only while a PD is being powered,
that is, while the attribute juiceBoxPortStatus is reporting
the enumeration deliveringPower or overPowerWarning.
If an overPowerFault has occured on the port, the power level that
caused the fault is indicatedro Gauge32 UNITS "milliWatts" .1.3.6.1.4.1.20364.1.1.1.1.7 |
juiceBoxMainObjects OBJECT IDENTIFIER .1.3.6.1.4.1.20364.1.1.2 |
juiceBoxMainSystemVoltageMeasured system voltage in millivolts .ro Gauge32 UNITS "milliVolts" .1.3.6.1.4.1.20364.1.1.2.1 |
juiceBoxMainTemperatureMeasured internal temperature in degrees C.ro Gauge32 UNITS "degrees C" .1.3.6.1.4.1.20364.1.1.2.2 |
juiceBoxMainPowerAvailableThe nominal power of the JuiceBox expressed in Watts.ro Gauge32 .1.3.6.1.4.1.20364.1.1.2.3 |
juiceBoxMainPowerDeliveredTotal Power Delivered to the PDs.ro Gauge32 UNITS "Watts" .1.3.6.1.4.1.20364.1.1.2.4 |
juiceBoxMainAllocatedPowerTotal Power Allocated to the PDs. This value is calculated base
on the Classification of the PDs powered by the Juice Box. If the PD
classified as Class 0 or Legacy, the juiceBoxPortMaxPower setting for
the port is used.ro Gauge32 UNITS "Watts" .1.3.6.1.4.1.20364.1.1.2.5 |
juiceBoxMainAllocatedPowerThresholdThe usage threshold expressed in percents for
comparing the alocated power and initiating
an alarm (trap) if the threshold is exceeded.rw Integer32 .1.3.6.1.4.1.20364.1.1.2.6 |
juiceBoxMainTrapDestinationIPAddrA read/write IP address. This is the address to which
the agent sends traps. The value is initialized as 0.0.0.0.
Traps will not be sent until a new value is enteredrw IpAddress .1.3.6.1.4.1.20364.1.1.2.7 |
juiceBoxMainTrapReXmitPeriodThe period of time in seconds after which a trap will be
re-transmitted if the fault condition is still presentrw Integer32 .1.3.6.1.4.1.20364.1.1.2.8 |
juiceBoxMainGlobalPortDetectionSettingSets the PortDetectionSetting for all the Juice Box ports to the
selected value.
Describes the type of PD detection performed by the port.
A value of disabled(1) means that no PD detection is performed. If a port
currently delivering power is set to disabled(1), power will be removed
from the port.
A value of ieee802.3afonly(2) means only PDs with valid signatures
as defined by ieee 802.3af will be detected and powered.
A value of ieee8023afandlegacy(3) means that PDs with 802.3af and legacy
signatures will be detected and powered.
A value of forcedon(4) means the port is powered without regard to detection status.
A setting of forcedon(4) is not persistent and must be re-asserted after restart/rebootrw Enumeration .1.3.6.1.4.1.20364.1.1.2.9 |
juiceBoxMainGlobalPortMaxPowerUsed to set PortMaxPower for all ports to the same value.
Describes the maximum power setting for the port in watts.
This setting is used by to calculate Allocated Power.
It is only used if the port is classified as Class 0 or Legacy.rw Enumeration .1.3.6.1.4.1.20364.1.1.2.10 |
juiceBoxMainNetworkControllerFirmwareFirmware Version of the JuiceBox Network Controller.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.20364.1.1.2.11 |
juiceBoxMainSystemControllerFirmwareFirmware Version of the JuiceBox SystemController.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.20364.1.1.2.12 |