Home/Catalog/RNX-UPDU-MIB

RNX-UPDU-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for RNX-UPDU-MIB.

UPDU MIB
Main OID:
rnx.1.3.6.1.4.1.55108
59
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

59 total
Object Name
rnxUPDU MIB
MODULE-IDENTITY
.1.3.6.1.4.1.55108
upduMib
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1
upduInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1.1
upduInfoPartNumberPart numberro
OCTET STRING
.1.3.6.1.4.1.55108.1.1.1
upduInfoSerialNumberSerial numberro
Integer32
.1.3.6.1.4.1.55108.1.1.2
upduInfoLotNumberLot numberro
OCTET STRING
.1.3.6.1.4.1.55108.1.1.3
upduInventory
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1.2
upduModuleTableA list of module entries.
SEQUENCE OF UpduModuleEntry
.1.3.6.1.4.1.55108.1.2.1
upduModuleEntryAn entry containing information for a particular module.
UpduModuleEntry
.1.3.6.1.4.1.55108.1.2.1.1
upduModuleIndexModule index.
Integer32
.1.3.6.1.4.1.55108.1.2.1.1.1
upduModuleTypeModule type: tells what type of module it is.ro
Enumeration
.1.3.6.1.4.1.55108.1.2.1.1.2
upduModulePartNumberPart numberro
OCTET STRING
.1.3.6.1.4.1.55108.1.2.1.1.3
upduModuleSerialNumberModule serial number.ro
Integer32
.1.3.6.1.4.1.55108.1.2.1.1.4
upduModuleLotNumberModule lot number.ro
OCTET STRING
.1.3.6.1.4.1.55108.1.2.1.1.5
upduMeasurements
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1.3
upduMeterTableHolds information about each Power module.
SEQUENCE OF UpduMeterEntry
.1.3.6.1.4.1.55108.1.3.1
upduMeterEntryAn entry provides a power data
UpduMeterEntry
.1.3.6.1.4.1.55108.1.3.1.1
upduMeterIndexNumber of the meter on the Module.
Integer32
.1.3.6.1.4.1.55108.1.3.1.1.1
upduMeterNameMeter name.ro
OCTET STRING
.1.3.6.1.4.1.55108.1.3.1.1.2
upduMeterTypeMeter type: Tell if the meter is per-phase, per PDU, per module or for a single outlet or outlet group. For pduTotalCalc, phaseTotalCalc, moduleTotalCalc, the total is calculated (sum of the measurements of the underlying objects). For the other totals, it is measured.ro
Enumeration
.1.3.6.1.4.1.55108.1.3.1.1.3
upduMeterEnergyPPositive active energy in watt hours.ro
WattHours UNITS "Wh"
.1.3.6.1.4.1.55108.1.3.1.1.4
upduMeterEnergyR1Reactive energy from quadrant R1 in volt-ampere reactives hours.ro
VoltAmpereReactiveHours UNITS "varh"
.1.3.6.1.4.1.55108.1.3.1.1.5
upduMeterEnergyR4Reactive energy from quadrant R4 in volt-ampere reactives hours.ro
VoltAmpereReactiveHours UNITS "varh"
.1.3.6.1.4.1.55108.1.3.1.1.6
upduMeterPowerPActive power at a given instant.ro
Watts UNITS "W"
.1.3.6.1.4.1.55108.1.3.1.1.7
upduMeterPowerQReactive power at a given instant.ro
VoltAmpereReactives UNITS "var"
.1.3.6.1.4.1.55108.1.3.1.1.8
upduMeterPowerSApparent power at a given instant.ro
VoltAmperes UNITS "VA"
.1.3.6.1.4.1.55108.1.3.1.1.9
upduMeterUrmsRMS voltage at a given instant.ro
MilliVolts UNITS "mV"
.1.3.6.1.4.1.55108.1.3.1.1.10
upduMeterIrmsRMS current at a given instant.ro
MilliAmperes UNITS "mA"
.1.3.6.1.4.1.55108.1.3.1.1.11
upduMeterSystemNameSystem-defined object name.ro
OCTET STRING
.1.3.6.1.4.1.55108.1.3.1.1.12
upduMeterCustomNameUser-configured unique object name. Write access has to be explicitly enabled in the UPDU configuration (see SNMP options).rw
OCTET STRING
.1.3.6.1.4.1.55108.1.3.1.1.13
upduMeterDescriptionUser-configured description. Write access has to be explicitly enabled in the UPDU configuration (see SNMP options).rw
OCTET STRING
.1.3.6.1.4.1.55108.1.3.1.1.14
upduMeterDataQualityDescribes the measurement data quality: ok if all is well and measurements are up to date, expired when measurements are not updated and represent the last known measurement, noData when no measurements of that meter are available (e.g. because of a missing license). When noData, 0 is returned for all measurement values.ro
Enumeration
.1.3.6.1.4.1.55108.1.3.1.1.15
upduSensorTableHolds information about sensors connected to the PDU.
SEQUENCE OF UpduSensorEntry
.1.3.6.1.4.1.55108.1.3.2
upduSensorEntryHolds the information related to one specific sensor.
UpduSensorEntry
.1.3.6.1.4.1.55108.1.3.2.1
upduSensorPortSensor port number.
Integer32
.1.3.6.1.4.1.55108.1.3.2.1.1
upduSensorPortNameSensor port name as printed on the front plate.ro
OCTET STRING
.1.3.6.1.4.1.55108.1.3.2.1.2
upduSensorTypeSensor type.ro
Enumeration
.1.3.6.1.4.1.55108.1.3.2.1.3
upduSensorTemperatureCelsiusTemperature in tenth degrees.ro
TenthDegreesCelsius UNITS "deg-C/10"
.1.3.6.1.4.1.55108.1.3.2.1.4
upduSensorHumidityRelative humidity in per mil. Set to 0 for temperature only sensor.ro
Permil UNITS "/1000"
.1.3.6.1.4.1.55108.1.3.2.1.5
upduRcmTableHolds information about embedded residual current monitors.
SEQUENCE OF UpduRcmEntry
.1.3.6.1.4.1.55108.1.3.3
upduRcmEntryAn entry provides Residual current data
UpduRcmEntry
.1.3.6.1.4.1.55108.1.3.3.1
upduRcmIndexRCM index.
Integer32
.1.3.6.1.4.1.55108.1.3.3.1.1
upduRcmNameRCM name.ro
OCTET STRING
.1.3.6.1.4.1.55108.1.3.3.1.2
upduRcmCurrentRmsRMS residual current.ro
TenthMilliAmperes UNITS "mA/10"
.1.3.6.1.4.1.55108.1.3.3.1.3
upduRcmCurrentDcDC residual current.ro
TenthMilliAmperes UNITS "mA/10"
.1.3.6.1.4.1.55108.1.3.3.1.4
upduRcmSensorQualityRCM sensor healthro
Enumeration
.1.3.6.1.4.1.55108.1.3.3.1.5
upduControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1.4
upduRelayTableHolds Relay state.
SEQUENCE OF UpduRelayEntry
.1.3.6.1.4.1.55108.1.4.1
upduRelayEntryAn entry provides the status for a relay.
UpduRelayEntry
.1.3.6.1.4.1.55108.1.4.1.1
upduRelayIndexRelay index.
Integer32
.1.3.6.1.4.1.55108.1.4.1.1.1
upduRelayMeterNamesComma-separated list of meter names this relay controls.ro
OCTET STRING
.1.3.6.1.4.1.55108.1.4.1.1.2
upduRelayAdminStatusDefines the desired state of the relay.rw
Enumeration
.1.3.6.1.4.1.55108.1.4.1.1.3
upduRelayOperStatusDefines the operational state of the relay.ro
Enumeration
.1.3.6.1.4.1.55108.1.4.1.1.4
upduRelayConditionGives the relay condition. Ok if the desired state corresponds to the operational state, failed if it differs and unknown if the operational state is not known.ro
Enumeration
.1.3.6.1.4.1.55108.1.4.1.1.5
upduConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1.5
upduMibCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1.5.1
upduMibComplianceThe compliance statement for SNMP entities which implement the RNX-UPDU-MIB.
Unknown
.1.3.6.1.4.1.55108.1.5.1.1
upduMibGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.55108.1.5.2
upduMibGroupRev1rev 1
Unknown
.1.3.6.1.4.1.55108.1.5.2.1
RNX-UPDU-MIB - SNMP MIB Reference | MIBs Explorer