RIELLOMDU-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
43
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
43 total| Object Name |
|---|
mduMIB OBJECT IDENTIFIER .1.3.6.1.4.1.5491.11 |
RFC1213-MIB Unknown .1.3.6.1.4.1.5491.11 |
mduIdent OBJECT IDENTIFIER .1.3.6.1.4.1.5491.11.1 |
mduIdentManufacturerThe name of the mdu manufacturer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5491.11.1.1 |
mduIdentModelThe mdu Model designation.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5491.11.1.2 |
mduIdentSoftwareVersionThe mdu Software version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5491.11.1.3 |
mduIdentIOConfigurationThe mdu input/output configuration (1 for Mono/mono, 4 for Tri/tri).ro INTEGER .1.3.6.1.4.1.5491.11.1.4 |
mduIdentInputSocketsThe number of mdu input sockets.ro INTEGER .1.3.6.1.4.1.5491.11.1.5 |
mduIdentOutputSocketsThe number of mdu output sockets.ro INTEGER .1.3.6.1.4.1.5491.11.1.6 |
mduIdentNominalCurrentThe mdu nominal current (A).ro INTEGER .1.3.6.1.4.1.5491.11.1.7 |
mduIdentNominalVoltageThe mdu nominal voltage (V).ro INTEGER .1.3.6.1.4.1.5491.11.1.8 |
mduIdentNominalFrequencyThe mdu nominal frequency (0.1 Hz).ro INTEGER .1.3.6.1.4.1.5491.11.1.9 |
mduStatus OBJECT IDENTIFIER .1.3.6.1.4.1.5491.11.2 |
mduLineAFrequencyThe frequency of source A (0.1 Hz).ro INTEGER .1.3.6.1.4.1.5491.11.2.1 |
mduLineAVoltageThe voltage of source 1 (V).ro INTEGER .1.3.6.1.4.1.5491.11.2.2 |
mduLineACurrentThe current of line A (0.1 A).ro INTEGER .1.3.6.1.4.1.5491.11.2.3 |
mduOutputA list of output table entries. SEQUENCE OF MduOutputSockets .1.3.6.1.4.1.5491.11.2.4 |
mduOutputSocketsAn entry containing information applicable to a
particular output line. MduOutputSockets .1.3.6.1.4.1.5491.11.2.4.1 |
mduOutputLineIndexThe line identifier. INTEGER .1.3.6.1.4.1.5491.11.2.4.1.1 |
mduOutputCurrentOutput current (0.1 A)ro INTEGER .1.3.6.1.4.1.5491.11.2.4.1.2 |
mduOutputDisabled1->line active, 2->line deactivatedro Enumeration .1.3.6.1.4.1.5491.11.2.4.1.3 |
mduOutputOverload1->line ok, 2->line deactivated for overloadro INTEGER .1.3.6.1.4.1.5491.11.2.4.1.4 |
mduOutputStatus0=OFF
1=ON
2= Shutdown active (when a CS or a CR command is received but shutdown is not yet been executed and the 'Imminent time' is not reached)
3= Shutdown imminent (S01 to S08 code)
4= Restore active (when after that a CR command is received and the shutdown has been acted but the restore delay time is not expired)
5= Overload alarm (F01 to F08 code)
6= Locked: OFF for overload (L01 to L08 code)ro Enumeration .1.3.6.1.4.1.5491.11.2.4.1.5 |
mduLowInputVoltage1= yes, 0= no.ro INTEGER .1.3.6.1.4.1.5491.11.2.5 |
mduHighInputVoltage1= yes, 0= no.ro INTEGER .1.3.6.1.4.1.5491.11.2.6 |
mduLowInputCurrent1= yes, 0= no.ro INTEGER .1.3.6.1.4.1.5491.11.2.7 |
mduHighInputCurrent1= yes, 0= no.ro INTEGER .1.3.6.1.4.1.5491.11.2.8 |
mduPowerFailAux11= yes, 0= no.ro INTEGER .1.3.6.1.4.1.5491.11.2.9 |
mduPowerFailAux21= yes, 0= no.ro INTEGER .1.3.6.1.4.1.5491.11.2.10 |
mduManualBypass1= on manual bypass, 0= no.ro INTEGER .1.3.6.1.4.1.5491.11.2.11 |
mduTemperatureThe temperature (oC).ro INTEGER .1.3.6.1.4.1.5491.11.2.12 |
mduCommand OBJECT IDENTIFIER .1.3.6.1.4.1.5491.11.3 |
mduCommandCodeThis object determines the nature of the action to be
taken at the time when the countdown of the
mduShutdownDelay and mduRestoreDelay objects reaches zero.
Setting this object to shutdown(1) indicates that
the specified sockets mduOutputSocketApplyCommand will yurn off.
Setting this object to restore(2) indicates that the specified output
sockets will turn on.
command delete(3) will delete the applied command, test panel will perform
a test of LCD panel and audible alarmrw Enumeration .1.3.6.1.4.1.5491.11.3.1 |
mduShutdownDelaySetting this object will shutdown (i.e., turn off)
either the MDU output socket by the value of mduCommandCode
at the time of shutdown after the indicated number of seconds.
Setting this object to 0 will cause the shutdown to occur
immediatelyrw INTEGER .1.3.6.1.4.1.5491.11.3.2 |
mduRestoreDelayThe restore delay.rw INTEGER .1.3.6.1.4.1.5491.11.3.3 |
mduOutputSocketApplyCommandSpecify the socket to apply the command, the value 0 apply to all sockets.rw INTEGER .1.3.6.1.4.1.5491.11.3.4 |
mduCommandResultThe command result, refer to the follow codes:
0+mduCommandCode Command in progress
256+mduCommandCode Wrong Command code
512+mduCommandCode Command is not handled
768+mduCommandCode Parameter out of range
3584+mduCommandCode Command sent to MDU
3840+mduCommandCode Command executedro INTEGER .1.3.6.1.4.1.5491.11.3.5 |
mduTraps OBJECT IDENTIFIER .1.3.6.1.4.1.5491.11.4 |
mduNormalThis trap is sent when MDU is on normal status TRAP-TYPE .1.3.6.1.4.1.5491.11.4.0.1 |
mduAnomalyThis trap is sent when MDU is has some anomaly and is resent every minute TRAP-TYPE .1.3.6.1.4.1.5491.11.4.0.2 |
mduFaultThis trap is sent when MDU is has some fault and is resent every minute TRAP-TYPE .1.3.6.1.4.1.5491.11.4.0.3 |
mduLockThis trap is sent when MDU is locked and is resent every minute TRAP-TYPE .1.3.6.1.4.1.5491.11.4.0.4 |
mduManualBypassEnabledThis trap is sent when MDU is on manual bypass and is resent every minute TRAP-TYPE .1.3.6.1.4.1.5491.11.4.0.5 |