Home/Catalog/REPEATER-MIB-2

REPEATER-MIB-2

AI MIB Summary

Standard SNMP MIB module defining data structures for REPEATER-MIB-2.

210
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

210 total
Object Name
IRM-OIDSThis object defines the board type for the Management board in the device. (eg. IRBM, IRM). See appendix A for values.ro
INTEGER
.1.3.6.1.4.1.52.1.1.1.1
deviceNameAn ASCII name of the device that this agent manages.rw
OCTET STRING
.1.3.6.1.4.1.52.1.1.1.2
deviceIPAddressThe Internet address of this device. Write access is granted only if SuperUser access is used.rw
NetworkAddress
.1.3.6.1.4.1.52.1.1.1.3
currentTimeThe current time of day as measured by the device in HHMMSS format.rw
OCTET STRING
.1.3.6.1.4.1.52.1.1.1.4
currentDateThe current date as measured by the device in MMDDYYYY format.rw
OCTET STRING
.1.3.6.1.4.1.52.1.1.1.5
mACAddressThe MAC (Ethernet) address of the MMAC. This can also be obtained from address translation MIB.ro
OCTET STRING
.1.3.6.1.4.1.52.1.1.1.6
soidMINIMMAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.1.2.3.1
soidMRXI
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.1.2.3.2
device
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.1
deviceMMACTypeIndicates the type of MMAC.ro
Enumeration
.1.3.6.1.4.1.52.1.2.1.1.2
deviceSlotsNumber of available slots in this device including the IRM slot.ro
Enumeration
.1.3.6.1.4.1.52.1.2.1.1.3
deviceOccupiedSlotsThe slots that contain MIM boards. This field is bit encoded (eg. If a bit is set then that board is present. For example, a value of 3 indicates that there are boards in the IRM slot and the first MIM slot.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.4
devicePortsOnA read will return the number of adminstratively ON ports for the device. A write of a 1 will administratively enable all the ports on the device, except for redundant ports.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.5
deviceTotalPortsThe total number of ports in the MMAC.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.6
deviceTotalPktsThe number of packets detected on all ports of this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.7
deviceTotalErrorsThe sum of all alignment, CRC, out-of-window collisions, runt, and giant errors detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.8
deviceTransmitCollsThe number of transmit collisions detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.9
deviceRecCollsThe number of receive collsions detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.10
deviceAlignsThe number of packets with alignment errors detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.11
deviceCRCsThe number of packets with bad CRC detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.12
deviceRuntsThe number of runt frames detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.13
deviceOOWCollsThe number of out-of-window collisions detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.14
deviceNoResourcesThe number of no resource condtions detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.15
deviceRecBytesThe number of bytes detected on the network by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.16
deviceGiantFramesThe number of longer than 1518 byte packets detected by this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.17
deviceRestartA read will return 0. A set of 0 will restart the device.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.18
deviceResetCountersA read will return 0. A set of 0 will reset all the counters for the device, boards and ports.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.19
deviceRedundantCtsThe number of redundant circuits available for use.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.20
deviceTimeBaseThe number of seconds used as the interval for performing all of the rate alarm checks. The minimum is 10 secs. There isn't a maximum.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.24
deviceResetRedundancyA read will return 0. A set of a 1 will reset redundancy for the entire box.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.25
deviceSrcAddrAgingTimeThe number of minutes that a source address is not detected before it is removed from the source address table. The minimum is 1 minute and the maximum is 1440 minutes (max minutes in a day).rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.26
deviceSrcAddrTrapsControls sending of source address related traps.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.1.27
deviceSrcAddrLockedA set of 2 will disable all ports that support link status but do not have link active, or is segmented. The first source address seen on each of the remaining enabled ports, that have the type of station, will be the only address allowed through that port. If any other address is seen the port will be disabled.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.1.28
deviceEnetBoardMapThe slots that contain Ethernet MIM boards. This field is bit encoded (e.g. If a bit is set then that board is present and is an Ethernet MIM.) For example, a value of 3 indicates that there are boards in the IRM slot and the first MIM slot and that these boards are Ethernet MIMs.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.29
deviceTokenRingBoardMapThe slots that contain Token Ring MIM boards. This field is bit encoded (e.g. If a bit is set then that board is present and is a Token Ring MIM.) For example, a value of 2 indicates that there is a board in the first slot and it is a Token Ring board.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.30
deviceFDDIBoardMapThe slots that contain FDDI MIM boards. This field is bit encoded (e.g. If a bit is set then that board is present and is a FDDI MIM.) For example, a value of 2 indicates that there is a board in the first slot and it is a FDDI board.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.31
deviceRestoreDefaultsA get will return 0. A set of 0 will restore all of battery backed RAM to factory defaults, with the execption of the IP address, the community table and the modem baud rate.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.32
deviceActiveUsersThe number of active users seen on this device.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.33
deviceBroadPktsThe sum of all of the broadcast packets detected on all ports of this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.48
deviceMultPktsThe sum of all of the multicast packets detected on all ports of this device.ro
Counter
.1.3.6.1.4.1.52.1.2.1.1.49
deviceThdPartyOccupiedSlotsThe slots that contain Third Party MIM boards. This field is bit encoded (eg. if a bit is set then that board is present and is a Third Party MIM.) For example, a value of 4 indicates that there is a board in the third MIM slot (slot 4) and that this board is a Third Party MIM.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.51
deviceImimOccupiedSlotsThe slots that contain IMIM boards. This field is bit encoded (eg. if a bit is set then that board is present and is an IMIM). For example, a value of 4 indicates that there is a board in the third MIM slot (slot 4) and that this board is an IMIM.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.1.52
deviceLinkTrapsControls sending of link related traps.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.1.54
deviceSegTrapsControls sending of seg related traps.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.1.55
ctIPDefaultFrameTypeDefines the default frame type that will be used by the device. A device will understand both frame types and will respond based upon the framing type that is learned for the given address. This object defines the type of framing that will be used if no framing is known, for example ARP requests. Setting a value of 8022snap(2) will result in framing 802.3 - 802.2 - IP packets being generated by default. Setting a value of ethernet(1) will result in framing ethernet IP packets by default.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.1.56
board
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.2
port
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.3
sourceAddr
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.7
sourceAddrBoardThe board number of the port that the supplied source address has been seen on.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.7.1
sourceAddrPortThe port number of the port that the supplied source address has been seen on.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.7.2
redundancy
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.8
redundancyPollIntervalThe number of seconds between polls for redundancy. The minimum is 0 and the maximum is 99.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.8.1
redundancyTestTodThe time of day at which the redundant circuits should be tested.rw
OCTET STRING
.1.3.6.1.4.1.52.1.2.1.8.2
redundancyPerformTestA read will return a 0. A set of a 1 will test the redundant circuits now.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.8.3
redundancyCircuitNameThe name of the indicated circuit.rw
OCTET STRING
.1.3.6.1.4.1.52.1.2.1.8.4
redundancyRetryCountThe number of unanswered polls allowed for the indicated circuit before the current connection is declared bad. The minimum is 0 the maximum is 16.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.8.5
redundancyNumBPsThe number of board/port combinations associated with the indicated circuit.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.8.6
redundancyCircuitBoardsThe boards associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circuit number followed by an index. The index has no other meaning than to be used as an index for the purposes of the GET NEXT operation.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.8.7
redundancyCircuitPortThe ports associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circuit number followed by an index. The index has no other meaning than to be used as an index for the purposes of the GET NEXT operation.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.8.8
redundancyCircuitTypesThe type of each port associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circuit number followed by an index. The index has no other meaning than to be used as an index for the purposes of the GET NEXT operation.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.8.9
redundancyCircuitNumAddrThe number of addresses associated with the indicated circuit.ro
INTEGER
.1.3.6.1.4.1.52.1.2.1.8.10
redundancyCircuitMACAddrAddA get will return a null string. A set adds an ethernet address to the polling list for the indicated circuit.rw
OCTET STRING
.1.3.6.1.4.1.52.1.2.1.8.11
redundancyCircuitMACAddrDelA get will return a null string. A set deletes an ethernet address from the polling list for the indicated circuit.rw
OCTET STRING
.1.3.6.1.4.1.52.1.2.1.8.12
redundancyCircuitMACAddrDispThe ethernet addresses associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circuit number followed by an index. The index has no other meaning than to be used as an index for the purposes of the GET NEXT operation.ro
OCTET STRING
.1.3.6.1.4.1.52.1.2.1.8.13
redundancyCircuitEnableEnables and disables the indicated circuit.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.8.14
redundancyCircuitResetA get will return 0. A set of 1 will reset the indicated circuit, return all of the associated board and ports to NOT-USED, remove associated addresses from the polling list, reset the circuit name and retry count to default values.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.8.15
alarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9
devAlrm
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.1
devTraffic
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.1.1
devTrafficEnableEnable or disable the checking for device level traffic thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.1.1.1
devTrafficThresholdThe number of packets detected by the device within the device timebase that will cause a device traffic alarm trap to be sent. The minimum is 0. There isn't a maximum.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.1.1.2
devColls
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.1.2
devCollsEnableEnable or disable the checking for device level collision thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.1.2.1
devCollsThresholdThe number of collisions per good packet detected by the device within the device timebase that will cause a device collision alarm trap to be sent. The minimum is 1, the maximum is 15.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.1.2.2
devError
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.1.3
devErrorEnableEnable or disable the checking for device level error thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.1.3.1
devErrorThresholdThe percentage of errors per good packet detected by the device within the device timebase that will cause a device error alarm trap to be sent. The minimum is 1, the maximum is 100.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.1.3.2
devErrorSourceThe type of errors used for the device error alarm. The INTEGER is a bit encoded version of which errors to include in the error sum. The bits are encoded as follows: CRC_errors - Bit 0 - Least Significant Bit runts - Bit 1 OOW_colls - Bit 2 align_errs - Bit 3 No_resource - Bit 4 Giants - Bit 5rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.1.3.3
devBroad
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.1.4
devBroadEnableEnable the sending of device level broadcast traps.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.1.4.1
devBroadThresholdThe threshold of broadcast packets within the Devicetimebase that will cause a broadcast alarm.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.1.4.2
bdAlrm
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.2
bdTraffic
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.2.1
bdTrafficEnableEnable or disable the checking for board level traffic thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.1.1
bdTrafficThresholdThe number of packets detected by the specified board within the device timebase that will cause a board traffic alarm trap to be sent. The minimum is 0. There isn't a maximum.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.2.1.2
bdTrafficBdDisablePermits a board to be disabled on a traffic threshold getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.1.3
bdColls
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.2.2
bdCollsEnableEnable or disable the checking for board level collision thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.2.1
bdCollsThresholdThe number of collisions per good packet detected by the specified board within the device timebase that will cause a board collision alarm trap to be sent. The minimum is 1, the maximum is 15.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.2.2.2
bdCollsBdDisablePermits a board to be disabled on a collision threshold getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.2.3
bdError
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.2.3
bdErrorEnableEnable or disable the checking for board level error thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.3.1
bdErrorThresholdThe percentage of errors per good packet detected by the specified board within the device timebase that will cause a board error alarm trap to be sent. The minimum is 1, the maximum is 100.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.2.3.2
bdErrorSourceThe type of errors used for the board error alarm. The INTEGER is a bit encoded version of which errors to include in the error sum. The bits are encoded as follows: CRC_errors - Bit 0 - Least Significant Bit runts - Bit 1 OOW_colls - Bit 2 align_errs - Bit 3 No_resource - Bit 4 Giants - Bit 5rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.2.3.3
bdErrorBdDisablePermits a board to be disabled on an error threshold getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.3.4
bdBroad
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.2.4
bdBroadEnableEnable the sending of board level broadcast traps for this board.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.4.1
bdBroadThresholdThe threshold of broadcast packets within the Devicetimebase that will cause a broadcast alarm.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.2.4.2
bdBroadDisablePermit a board to be disabled on a broadcast threshold alarm.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.2.4.3
portAlrm
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.3
portTraffic
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.3.1
portTrafficEnableEnable or disable the checking for port level traffic thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.1.1
portTrafficThresholdThe number of packets detected by the specified port within the device timebase that will cause a port traffic alarm trap to be sent. The minimum is 0. There isn't a maximum.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.3.1.2
portTrafficPortDisablePermits a port to be disabled on a traffic threshold getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.1.3
portColls
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.3.2
portCollsEnableEnable or disable the checking for port level collision thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.2.1
portCollsThresholdThe number of collisions per good packet detected by the specified port within the device timebase that will cause a port collision alarm trap to be sent. The minimum is 1, the maximum is 15.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.3.2.2
portCollsPortDisablePermits a port to be disabled on a collision threshold getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.2.3
portError
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.3.3
portErrorEnableEnable or disable the checking for port level error thresholds getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.3.1
portErrorThresholdThe percentage of errors per good packet detected by the specified port within the device timebase that will cause a port error alarm trap to be sent. The minimum is 1, the maximum is 100.rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.3.3.2
portErrorSourceThe type of errors used for the port error alarm. The INTEGER is a bit encoded version of which errors to include in the error sum. The bits are encoded as follows: CRC_errors - Bit 0 - Least Significant Bit runts - Bit 1 OOW_colls - Bit 2 align_errs - Bit 3 No_resource - Bit 4 Giants - Bit 5rw
INTEGER
.1.3.6.1.4.1.52.1.2.1.9.3.3.3
portErrorPortDisablePermits a port to be disabled on an error threshold getting exceeded.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.3.4
portBroad
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.1.9.3.4
portBroadEnableEnable the sending of port level broadcast alarms.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.4.1
portBroadThresholdThe threshold of broadcast packets within the Devicetimebase that will cause a broadcast alarm.rw
Counter
.1.3.6.1.4.1.52.1.2.1.9.3.4.2
portBroadDisablePermit a port to be disabled on a broadcast threshold alarm.rw
Enumeration
.1.3.6.1.4.1.52.1.2.1.9.3.4.3
rr2device
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.1
commonD
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.1.1
ethernetD
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.1.2
tokenRingD
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.1.3
deviceTRTokenRingPortsOnThe number of Token Ring Ports (i.e. station, Ring In and Ring Out ports) administratively ON for this device.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.1.3.1
deviceTRTotalTokenRingPortsThe total number of Token Ring Ports (i.e. station, Ring In and Ring Out ports) on this device.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.1.3.2
deviceTRTotalTokenRingRingPortsOnThe total number of Ring In and Ring Out ports (active) administratively ON for this device.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.1.3.3
deviceTRTotalTokenRingRingPortsThe total number of Ring In and Ring Out ports on this device.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.1.3.4
deviceTRTotalTokenRingRingsThe total number of (Token Ring) rings formed on this device.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.1.3.5
deviceTRTotalTokenRingBoardsThe total number of Token Ring MIMs in the MMAC.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.1.3.6
deviceTRTokenRingBoardMapThe slots that contain Token Ring MIM boards. This field is bit encoded (e.g. If a bit is set then that board is present and is a Token Ring MIM.) For example, a value of 2 indicates that there is a board in the first slot and it is a Token Ring board.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.1.3.7
network
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.2
rr2board
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.3
commonB
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.3.1
boardIndexThe slot number of this board.ro
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.1.1
boardNameThe name of the board. This field will only contain printable ASCII characters.rw
OCTET STRING
.1.3.6.1.4.1.52.1.2.2.3.1.2
boardTypeThe type of the MIM. (eg. FOT, TPT, etc). See appendix A for encoding.ro
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.1.3
boardTotalPortsTotal number of ports supported on this board.ro
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.1.4
boardPortsOnA read will return the number of adminstratively ON ports for the board. A write of a 2 will administratively enable all the ports on the board, except for redundant ports.rw
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.1.6
boardActiveUsersThe number of active users seen on this board.ro
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.1.8
ethernetB
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.3.2
boardTotalPktsThe number of packets detected on all ports of this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.1
boardTotalErrorsThe sum of all alignment, CRC, out-of-window collisions, runt, and giant errors detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.2
boardTransCollsThe number of transmit collisions detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.3
boardRecCollsThe number of receive collsions detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.4
boardAlignsThe number of packets with alignment errors detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.5
boardCRCsThe number of packets with bad CRC detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.6
boardRuntsThe number of runt frames detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.7
boardOOWCollsThe number of out-of-window collisions detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.8
boardNoResourcesThe number of no resource condtions detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.9
boardRecBytesThe number of bytes detected on the network by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.10
boardGiantsThe number of longer than 1518 byte packets detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.11
boardBroadPktsThe number broadcast packets detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.26
boardMultPktsThe number multicast packets detected by this board.ro
Counter
.1.3.6.1.4.1.52.1.2.2.3.2.27
tokenRingB
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.3.3
boardTotalRingPortsThe total number of ring ports on this board. Currently, zero or two.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.3.1
boardTotalStationPortsThe total number of station ports on this board.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.3.2
boardModeStatusThe board mode.rwdeprecated
Enumeration
.1.3.6.1.4.1.52.1.2.2.3.3.3
boardTotalRingPortsOnThe number of administartively ON ring ports on this board.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.3.4
boardTotalStationPortsOnThe number of administartively ON station ports on this board.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.3.5
boardSpeedThe board speed.rwdeprecated
Enumeration
.1.3.6.1.4.1.52.1.2.2.3.3.6
boardRingSpeedFaultData speed of station mismatches configuration speed of board. Board is automatically bypassed.rodeprecated
Enumeration
.1.3.6.1.4.1.52.1.2.2.3.3.7
boardFirstRingPortThe port number of the first ring port.rodeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.3.3.9
fddiB
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.3.4
rr2port
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.4
commonP
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.4.1
portIndexThe number of this port relative to the board it is on.ro
INTEGER
.1.3.6.1.4.1.52.1.2.2.4.1.1
portMediaTypeThe type of the port. (eg. FOT, TPT, etc). See appendix A for values.ro
INTEGER
.1.3.6.1.4.1.52.1.2.2.4.1.2
portAdminStateThe administrative status of this port.rw
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.1.3
portSourceAddrA source address that has been seen on this port.ro
OCTET STRING
.1.3.6.1.4.1.52.1.2.2.4.1.4
portActiveUsersThe number of active users seen on this port.ro
INTEGER
.1.3.6.1.4.1.52.1.2.2.4.1.6
ethernetP
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.4.2
portTopologyTypeThe topological type of the port. Station referring to a port that has seen 1 or 0 addresses. Trunk referring to a port that has seen more than 1 address.ro
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.2.1
portLinkStatusThe state of the link signal for this portro
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.2.2
portStatusThe hardware status of the port.ro
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.2.3
portTotalPktsThe number of packets detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.4
portTotalErrorsThe sum of all alignment, CRC, out-of-window collisions, runt, and giant errors detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.5
portTransmitCollsThe number of transmit collisions detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.6
portRecCollsThe number of receive collsions detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.7
portAlignsThe number of packets with alignment errors detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.8
portCRCsThe number of packets with bad CRC detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.9
portRuntsThe number of runt frames detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.10
portOOWCollsThe number of out-of-window collisions detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.11
portNoResourcesThe number of no resource condtions detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.12
portRecBytesThe number of bytes detected on the network by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.13
portGiantFramesThe number of longer than 1518 byte packets detected by this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.14
portRedundCrtThe redundant circuit with which this port is associated.rw
INTEGER
.1.3.6.1.4.1.52.1.2.2.4.2.15
portRedundTypeThe type of port this port is in the redundant circuit.rw
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.2.16
portRedundStatusThe current state of this port in the redundant circuit.rw
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.2.17
portForceTrunkTypeThis variable forces a port to be a trunk port.rw
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.2.18
portBroadPktsThe sum of broadcast packets detected on this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.33
portMultPktsThe sum of multicast packets detected on this port.ro
Counter
.1.3.6.1.4.1.52.1.2.2.4.2.34
tokenRingP
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.4.3
stationP
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.4.3.1
stationPortLinkStatusWhen station is supplying phantom current the Link Signal is active. When there is no phantom current the Link Signal is inactive.rodeprecated
Enumeration
.1.3.6.1.4.1.52.1.2.2.4.3.1.1
stationPortLinkStateTimeThe amount of time (in seconds) elapsed since the station port last changed state. A write of 0 will reset the elapsed time.rwdeprecated
INTEGER
.1.3.6.1.4.1.52.1.2.2.4.3.1.2
ringP
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.4.3.2
fddiP
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.4.4
repeaterTables
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.2.2.5
fnb
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.6.1.1
fnbConnectedLeftThe Connected Left board (board n + 1) has the following states: Detached == 1 (Management (only management) detached, read/write). Attached == 2 (Management/AutoMode attached, read/write). Faulted == 3 (Management/AutoMode tried to attach but failed read ONLY).rw
INTEGER
.1.3.6.1.4.1.52.1.6.1.1.1
fnbConnectedRightThe Connected Right board (board n - 1) has the following states: Detached == 1 (Management (only management) detached, read/write). Attached == 2 (Management/AutoMode attached, read/write). Faulted == 3 (Management/AutoMode tried to attach but failed read ONLY).rw
INTEGER
.1.3.6.1.4.1.52.1.6.1.1.2
fnbBoardBypassStateOff == 1 (NOT bypassed). On == 2 (bypassed).rw
INTEGER
.1.3.6.1.4.1.52.1.6.1.1.3
audibleAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.1.6.1.2
audibleAlarmEnableAllows/disallows the audible alarm to be sounded when a situation occurs that the alarm should be sounded.rw
Enumeration
.1.3.6.1.4.1.52.1.6.1.2.1
audibleAlarmOffTurn off a sounding alarm. A read will tell you if the alarm is on or not. A write will stop a sounding alarm.rw
Enumeration
.1.3.6.1.4.1.52.1.6.1.2.2
productRev1
OBJECT IDENTIFIER
.1.3.6.1.4.1.412.2.3.5.1.3.1
target
OBJECT IDENTIFIER
.1.3.6.1.4.1.412.2.3.5.1.3.1.1
targetRevisionThe revision of the target board.ro
INTEGER
.1.3.6.1.4.1.412.2.3.5.1.3.1.1.1
targetPortAssociationControls how the front panel ports are associated with the bridge or the repeater. The valid values are: Value AUI Port Fiber Port 0 Bridge Redundant 1 Redundant Bridge 2 Bridge Repeater 3 Repeater Bridge 4 Redundant Repeater 5 Repeater Redundant Note: only values 0 and 1 are valid for rev 2 boards and before. Note: only values 4 and 5 are valid for the IRM2.rw
INTEGER
.1.3.6.1.4.1.412.2.3.5.1.3.1.1.2
soidIRMSNMP
OBJECT IDENTIFIER
.1.3.6.1.4.1.3375.2.1.3.2.1
soidIRBM
OBJECT IDENTIFIER
.1.3.6.1.4.1.3375.2.1.3.2.2
soidIRM2
OBJECT IDENTIFIER
.1.3.6.1.4.1.3375.2.1.3.2.3