Home/Catalog/PRVT-SYNC-ETHERNET-MIB

PRVT-SYNC-ETHERNET-MIB

AI MIB Summary

The PRVT-SYNC-ETHERNET-MIB module enables the monitoring and management of Precision Time Protocol (PTP) and Synchronization Ethernet (SyncE) state variables, including clock quality, stratum levels, and synchronization status, on network interface cards and switches supporting IEEE 1588 and IEEE 802.1AS standards.

This is the MIB module to manage synchronization over ethernet.
Main OID:
prvtSyncEthernetMIB.1.3.6.1.4.1.738.1.5.170
62
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

62 total
Object Name
prvtSyncEthernetMIBThis is the MIB module to manage synchronization over ethernet.
MODULE-IDENTITY
.1.3.6.1.4.1.738.1.5.170
prvtSyncEthernetMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.738.1.5.170.0
syncEthernetInvalidESMCInvalid ESMC has been received.
NOTIFICATION-TYPE
.1.3.6.1.4.1.738.1.5.170.0.1
syncEthernetQualityLevelChangeCurrent value of syncEthernetClockSourceQuality has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.738.1.5.170.0.2
syncEthernetInvalidQualityLevelReceivedInvalid Quality level equals to QL-INVx has been received.
NOTIFICATION-TYPE
.1.3.6.1.4.1.738.1.5.170.0.3
syncEthernetDPLLReferenceChangeDPLL's reference clock changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.738.1.5.170.0.4
syncEthernetDPLLChangedSome of the DPLL's operational status changes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.738.1.5.170.0.5
syncEthernetDPLLLockFailedIf after new Reference selection the DPLL can't lock onto it, this will affect the Clock Source associated with that reference
NOTIFICATION-TYPE
.1.3.6.1.4.1.738.1.5.170.0.6
prvtSyncEthernetMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.738.1.5.170.1
syncEthernetHoldOffTimeTimeout value, in millisseconds, for the hold-off timer.rw
Integer32
.1.3.6.1.4.1.738.1.5.170.1.1
syncEthernetWaitToRestoreTimeTimeout value, in minutes, for the wait-to-restore timer.rw
Integer32
.1.3.6.1.4.1.738.1.5.170.1.2
syncEthernetG781OptionModeSpecify which G.781 option mode to operate in.rw
Enumeration
.1.3.6.1.4.1.738.1.5.170.1.3
syncEthernetClockSourceTableSource clock synchronization table.
SEQUENCE OF SyncEthernetClockSourceEntry
.1.3.6.1.4.1.738.1.5.170.1.10
syncEthernetClockSourceEntrySource clock synchronization entry.
SyncEthernetClockSourceEntry
.1.3.6.1.4.1.738.1.5.170.1.10.1
syncEthernetClockSourceRowStatusClock source synchronization table rowstatus.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.10.1.2
syncEthernetClockSourceAdminStatusEnable clock source.rw
Enumeration
.1.3.6.1.4.1.738.1.5.170.1.10.1.3
syncEthernetClockSourceEsmcEnable receiving ESMC messages (Synchronization Status Messages). Only applicable for BITS clock sources.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.10.1.4
syncEthernetClockSourceFrequencySpecify input frequency - N*8kHz Only applicable for BITS clock sources.rw
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.10.1.5
syncEthernetClockSourceQualitySpecify quality level In G781-option I mode, valid values are prs, ssuA, ssuB, dnu. In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov.rw
PrvtSyncEthernetQualityLevelType
.1.3.6.1.4.1.738.1.5.170.1.10.1.6
syncEthernetClockSourceQualityChangeNotifyEnable quality level change notificationsrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.10.1.7
syncEthernetClockSourceRecvQualityLevelThe received quality level value.ro
PrvtSyncEthernetQualityLevelType
.1.3.6.1.4.1.738.1.5.170.1.10.1.8
syncEthernetClockSourceLastRecvEsmcPduTimeTime elapsed since the last valid ESMC message receivedro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.10.1.9
syncEthernetClockSourceLastRecvEsmcErrorPduTimeTime elapsed since the last invalid ESMC message receivedro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.10.1.10
syncEthernetClockSourceLastRecvEsmcPduTypeLast received ESMC message typero
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.10.1.11
syncEthernetClockSourceLastRecvLastErrorLast error codero
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.10.1.12
syncEthernetClockSourceNumRecvEsmcPduTotal number of received ESMC messagesro
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.10.1.13
syncEthernetClockSourceNumDiscEsmcPduTotal number of discarded ESMC messagesro
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.10.1.14
syncEthernetClockSourceNumSignalFailTotal number of generated signal failure eventsro
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.10.1.15
syncEthernetClockSourceQualityInvalidNotifyEnable invalid quality notificationsrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.10.1.16
syncEthernetClockSourceEsmcInvalidNotifyEnable invalid ESMC notificationsrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.10.1.17
syncEthernetClockOutputTableOutput clock synchronization table.
SEQUENCE OF SyncEthernetClockOutputEntry
.1.3.6.1.4.1.738.1.5.170.1.12
syncEthernetClockOutputEntryOutput clock synchronization entry.
SyncEthernetClockOutputEntry
.1.3.6.1.4.1.738.1.5.170.1.12.1
syncEthernetClockOutputRowStatussyncEthernetClockOutput table rowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.12.1.2
syncEthernetClockOutputEsmcEnable sending ESMC messages Only applicable for BITS clock outputs.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.12.1.3
syncEthernetClockOutputFrequencySpecify output frequency - N*8kHz Only applicable for BITS clock outputs.rw
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.12.1.4
syncEthernetClockOutputDpllAssign output clock to DPLL Only applicable for BITS clock outputs. Must be set to the syncEthernetDpllModuleId value of an existing row in syncEthernetDpllTable.rw
Integer32
.1.3.6.1.4.1.738.1.5.170.1.12.1.5
syncEthernetClockOutputQualityLevelLast quality level value sentro
PrvtSyncEthernetQualityLevelType
.1.3.6.1.4.1.738.1.5.170.1.12.1.6
syncEthernetClockOutputLastQualityLevelChangeTime elapsed since the last quality level changero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.12.1.7
syncEthernetClockOutputMsgEventLast ESMC message type sentro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.12.1.8
syncEthernetClockOutputNumTransmittedEsmcPduTotal number of ESMC messages sentro
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.12.1.9
syncEthernetClockOutputNumTransmittedEventEsmcPduTotal number of ESMC messages sentro
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.12.1.10
syncEthernetDpllTableSynchronization DPLL table
SEQUENCE OF SyncEthernetDpllEntry
.1.3.6.1.4.1.738.1.5.170.1.14
syncEthernetDpllEntrySynchronization DPLL entry
SyncEthernetDpllEntry
.1.3.6.1.4.1.738.1.5.170.1.14.1
syncEthernetDpllModuleIdSynchronization DPLL module index
Integer32
.1.3.6.1.4.1.738.1.5.170.1.14.1.1
syncEthernetDpllRowStatusSynchronization DPLL rowstatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.14.1.2
syncEthernetDpllAdminStatusAdministrative status of the DPLLrw
Enumeration
.1.3.6.1.4.1.738.1.5.170.1.14.1.3
syncEthernetDpllReferenceSelectionSpecify reference selection moderw
Enumeration
.1.3.6.1.4.1.738.1.5.170.1.14.1.4
syncEthernetDpllEnableQualityLevelEnable reference selection based on quality level Only applicable when syncEthernetDpllReferenceSelection equals g781.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.14.1.5
syncEthernetDpllStatusChangeNotifyEnable DPLL status change notificationsrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.14.1.6
syncEthernetDpllReferenceChangeNotifyEnable reference clock change notificationsrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.14.1.7
syncEthernetDpllStatusDPLL operational statusro
Enumeration
.1.3.6.1.4.1.738.1.5.170.1.14.1.8
syncEthernetDpllStatusLastChangeTime since last DPLL status changero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.14.1.9
syncEthernetDpllSystemQualityLevelSystem quality levelro
PrvtSyncEthernetQualityLevelType
.1.3.6.1.4.1.738.1.5.170.1.14.1.10
syncEthernetDpllSystemQualityLevelLastChangeTime since last system quality level changero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.14.1.11
syncEthernetDpllSelectedReferenceClockThe selected reference clock sourcero
OCTET STRING
.1.3.6.1.4.1.738.1.5.170.1.14.1.12
syncEthernetDpllSelectedReferenceClockChangeTime since last reference clock changero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.14.1.13
syncEthernetDpllClkRefTableSynchronization DPLL clock reference table
SEQUENCE OF SyncEthernetDpllClkRefEntry
.1.3.6.1.4.1.738.1.5.170.1.16
syncEthernetDpllClkRefEntrySynchronization DPLL clock reference entry
SyncEthernetDpllClkRefEntry
.1.3.6.1.4.1.738.1.5.170.1.16.1
syncEthernetDpllClkRefRowStatusSynchronization DPLL clock reference rowstatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.16.1.2
syncEthernetDpllClkRefPrioritySpecify reference clock priorityrw
Unsigned32
.1.3.6.1.4.1.738.1.5.170.1.16.1.3
syncEthernetDpllClkRefLockOutLock reference clockrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.738.1.5.170.1.16.1.4
syncEthernetDpllClkRefFailStatusDPLL reference clock statusro
Integer32
.1.3.6.1.4.1.738.1.5.170.1.16.1.5
PRVT-SYNC-ETHERNET-MIB - SNMP MIB Reference | MIBs Explorer