PRVT-SYNC-ETHERNET-MIB
AI MIB Summary
The PRVT-SYNC-ETHERNET-MIB module enables the monitoring and management of Precision Time Protocol (PTP) and Synchronization Ethernet (SyncE) state variables, including clock quality, stratum levels, and synchronization status, on network interface cards and switches supporting IEEE 1588 and IEEE 802.1AS standards.
This is the MIB module to manage synchronization over ethernet.
Main OID:
prvtSyncEthernetMIB.1.3.6.1.4.1.738.1.5.170
62
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
62 total| Object Name |
|---|
prvtSyncEthernetMIBThis is the MIB module to manage synchronization over ethernet. MODULE-IDENTITY .1.3.6.1.4.1.738.1.5.170 |
prvtSyncEthernetMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.170.0 |
syncEthernetInvalidESMCInvalid ESMC has been received. NOTIFICATION-TYPE .1.3.6.1.4.1.738.1.5.170.0.1 |
syncEthernetQualityLevelChangeCurrent value of syncEthernetClockSourceQuality has been changed. NOTIFICATION-TYPE .1.3.6.1.4.1.738.1.5.170.0.2 |
syncEthernetInvalidQualityLevelReceivedInvalid Quality level equals to QL-INVx has been received. NOTIFICATION-TYPE .1.3.6.1.4.1.738.1.5.170.0.3 |
syncEthernetDPLLReferenceChangeDPLL's reference clock changed. NOTIFICATION-TYPE .1.3.6.1.4.1.738.1.5.170.0.4 |
syncEthernetDPLLChangedSome of the DPLL's operational status changes. NOTIFICATION-TYPE .1.3.6.1.4.1.738.1.5.170.0.5 |
syncEthernetDPLLLockFailedIf after new Reference selection the DPLL can't lock onto it, this will affect the Clock Source associated with that reference NOTIFICATION-TYPE .1.3.6.1.4.1.738.1.5.170.0.6 |
prvtSyncEthernetMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.170.1 |
syncEthernetHoldOffTimeTimeout value, in millisseconds, for the hold-off timer.rw Integer32 .1.3.6.1.4.1.738.1.5.170.1.1 |
syncEthernetWaitToRestoreTimeTimeout value, in minutes, for the wait-to-restore timer.rw Integer32 .1.3.6.1.4.1.738.1.5.170.1.2 |
syncEthernetG781OptionModeSpecify which G.781 option mode to operate in.rw Enumeration .1.3.6.1.4.1.738.1.5.170.1.3 |
syncEthernetClockSourceTableSource clock synchronization table. SEQUENCE OF SyncEthernetClockSourceEntry .1.3.6.1.4.1.738.1.5.170.1.10 |
syncEthernetClockSourceEntrySource clock synchronization entry. SyncEthernetClockSourceEntry .1.3.6.1.4.1.738.1.5.170.1.10.1 |
syncEthernetClockSourceRowStatusClock source synchronization table rowstatus.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.10.1.2 |
syncEthernetClockSourceAdminStatusEnable clock source.rw Enumeration .1.3.6.1.4.1.738.1.5.170.1.10.1.3 |
syncEthernetClockSourceEsmcEnable receiving ESMC messages (Synchronization Status Messages). Only applicable for BITS clock sources.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.10.1.4 |
syncEthernetClockSourceFrequencySpecify input frequency - N*8kHz Only applicable for BITS clock sources.rw Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.10.1.5 |
syncEthernetClockSourceQualitySpecify quality level In G781-option I mode, valid values are prs, ssuA, ssuB, dnu. In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov.rw PrvtSyncEthernetQualityLevelType .1.3.6.1.4.1.738.1.5.170.1.10.1.6 |
syncEthernetClockSourceQualityChangeNotifyEnable quality level change notificationsrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.10.1.7 |
syncEthernetClockSourceRecvQualityLevelThe received quality level value.ro PrvtSyncEthernetQualityLevelType .1.3.6.1.4.1.738.1.5.170.1.10.1.8 |
syncEthernetClockSourceLastRecvEsmcPduTimeTime elapsed since the last valid ESMC message receivedro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.10.1.9 |
syncEthernetClockSourceLastRecvEsmcErrorPduTimeTime elapsed since the last invalid ESMC message receivedro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.10.1.10 |
syncEthernetClockSourceLastRecvEsmcPduTypeLast received ESMC message typero Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.10.1.11 |
syncEthernetClockSourceLastRecvLastErrorLast error codero Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.10.1.12 |
syncEthernetClockSourceNumRecvEsmcPduTotal number of received ESMC messagesro Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.10.1.13 |
syncEthernetClockSourceNumDiscEsmcPduTotal number of discarded ESMC messagesro Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.10.1.14 |
syncEthernetClockSourceNumSignalFailTotal number of generated signal failure eventsro Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.10.1.15 |
syncEthernetClockSourceQualityInvalidNotifyEnable invalid quality notificationsrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.10.1.16 |
syncEthernetClockSourceEsmcInvalidNotifyEnable invalid ESMC notificationsrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.10.1.17 |
syncEthernetClockOutputTableOutput clock synchronization table. SEQUENCE OF SyncEthernetClockOutputEntry .1.3.6.1.4.1.738.1.5.170.1.12 |
syncEthernetClockOutputEntryOutput clock synchronization entry. SyncEthernetClockOutputEntry .1.3.6.1.4.1.738.1.5.170.1.12.1 |
syncEthernetClockOutputRowStatussyncEthernetClockOutput table rowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.12.1.2 |
syncEthernetClockOutputEsmcEnable sending ESMC messages Only applicable for BITS clock outputs.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.12.1.3 |
syncEthernetClockOutputFrequencySpecify output frequency - N*8kHz Only applicable for BITS clock outputs.rw Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.12.1.4 |
syncEthernetClockOutputDpllAssign output clock to DPLL Only applicable for BITS clock outputs. Must be set to the syncEthernetDpllModuleId value of an existing row in syncEthernetDpllTable.rw Integer32 .1.3.6.1.4.1.738.1.5.170.1.12.1.5 |
syncEthernetClockOutputQualityLevelLast quality level value sentro PrvtSyncEthernetQualityLevelType .1.3.6.1.4.1.738.1.5.170.1.12.1.6 |
syncEthernetClockOutputLastQualityLevelChangeTime elapsed since the last quality level changero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.12.1.7 |
syncEthernetClockOutputMsgEventLast ESMC message type sentro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.12.1.8 |
syncEthernetClockOutputNumTransmittedEsmcPduTotal number of ESMC messages sentro Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.12.1.9 |
syncEthernetClockOutputNumTransmittedEventEsmcPduTotal number of ESMC messages sentro Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.12.1.10 |
syncEthernetDpllTableSynchronization DPLL table SEQUENCE OF SyncEthernetDpllEntry .1.3.6.1.4.1.738.1.5.170.1.14 |
syncEthernetDpllEntrySynchronization DPLL entry SyncEthernetDpllEntry .1.3.6.1.4.1.738.1.5.170.1.14.1 |
syncEthernetDpllModuleIdSynchronization DPLL module index Integer32 .1.3.6.1.4.1.738.1.5.170.1.14.1.1 |
syncEthernetDpllRowStatusSynchronization DPLL rowstatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.14.1.2 |
syncEthernetDpllAdminStatusAdministrative status of the DPLLrw Enumeration .1.3.6.1.4.1.738.1.5.170.1.14.1.3 |
syncEthernetDpllReferenceSelectionSpecify reference selection moderw Enumeration .1.3.6.1.4.1.738.1.5.170.1.14.1.4 |
syncEthernetDpllEnableQualityLevelEnable reference selection based on quality level Only applicable when syncEthernetDpllReferenceSelection equals g781.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.14.1.5 |
syncEthernetDpllStatusChangeNotifyEnable DPLL status change notificationsrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.14.1.6 |
syncEthernetDpllReferenceChangeNotifyEnable reference clock change notificationsrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.14.1.7 |
syncEthernetDpllStatusDPLL operational statusro Enumeration .1.3.6.1.4.1.738.1.5.170.1.14.1.8 |
syncEthernetDpllStatusLastChangeTime since last DPLL status changero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.14.1.9 |
syncEthernetDpllSystemQualityLevelSystem quality levelro PrvtSyncEthernetQualityLevelType .1.3.6.1.4.1.738.1.5.170.1.14.1.10 |
syncEthernetDpllSystemQualityLevelLastChangeTime since last system quality level changero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.14.1.11 |
syncEthernetDpllSelectedReferenceClockThe selected reference clock sourcero OCTET STRING .1.3.6.1.4.1.738.1.5.170.1.14.1.12 |
syncEthernetDpllSelectedReferenceClockChangeTime since last reference clock changero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.14.1.13 |
syncEthernetDpllClkRefTableSynchronization DPLL clock reference table SEQUENCE OF SyncEthernetDpllClkRefEntry .1.3.6.1.4.1.738.1.5.170.1.16 |
syncEthernetDpllClkRefEntrySynchronization DPLL clock reference entry SyncEthernetDpllClkRefEntry .1.3.6.1.4.1.738.1.5.170.1.16.1 |
syncEthernetDpllClkRefRowStatusSynchronization DPLL clock reference rowstatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.16.1.2 |
syncEthernetDpllClkRefPrioritySpecify reference clock priorityrw Unsigned32 .1.3.6.1.4.1.738.1.5.170.1.16.1.3 |
syncEthernetDpllClkRefLockOutLock reference clockrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.738.1.5.170.1.16.1.4 |
syncEthernetDpllClkRefFailStatusDPLL reference clock statusro Integer32 .1.3.6.1.4.1.738.1.5.170.1.16.1.5 |