PRVT-OPR-LED-MANAGEMENT-MIB
AI MIB Summary
The PRVT-OPR-LED-MANAGEMENT-MIB enables SNMP-based remote control of the Operational (OPR) LED status indicators on supported network switches. This module facilitates physical device status verification and troubleshooting by allowing administrators to programmatically toggle or query the LED state without physical console access.
Initial version. This MIB will provied a way to control the status of the state OPR LED for certain switches
Main OID:
prvtOprLedMgmtMIB.1.3.6.1.4.1.738.1.5.110
5
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
5 total| Object Name |
|---|
prvtOprLedMgmtMIBInitial version. This MIB will provied a way to control the status of the state OPR LED for certain switches MODULE-IDENTITY .1.3.6.1.4.1.738.1.5.110 |
prvtOprLedMgmtObjects OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.110.1 |
prvtOprLedSatusAll possible led states. States red-stable and red-blinking can not be set. States amber-stable and amber-blinking green-blinking can be set only when the current state is green-stable. The object has read-write access and its default value is green-stablerw LedValues .1.3.6.1.4.1.738.1.5.110.1.1 |
prvtOprLedMgmtNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.110.2 |
prvtOprLedMgmtConformance OBJECT IDENTIFIER .1.3.6.1.4.1.738.1.5.110.3 |