Home/Catalog/PRVT-DRY-CONTACTS-MIB

PRVT-DRY-CONTACTS-MIB

AI MIB Summary

The PRVT-DRY-CONTACTS-MIB monitors the binary state (open/closed) of external dry-contact alarm inputs on network hardware to facilitate real-time notification of physical security or environmental events. It enables the translation of discrete contact closures into SNMP trap notifications for integration with centralized monitoring systems.

Initial version. This MIB provides external-alarm management and notifications
Main OID:
prvtDryContactsMIB.1.3.6.1.4.1.738.1.5.112
15
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

15 total
Object Name
prvtDryContactsMIBInitial version. This MIB provides external-alarm management and notifications
MODULE-IDENTITY
.1.3.6.1.4.1.738.1.5.112
dryContactsNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.738.1.5.112.0
stateChangedSend notification when operational status of the input changes
NOTIFICATION-TYPE
.1.3.6.1.4.1.738.1.5.112.0.1
dryContactsObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.738.1.5.112.1
cfgTableA table containing inputs configuration and statuses
SEQUENCE OF CfgEntry
.1.3.6.1.4.1.738.1.5.112.1.1
cfgEntrycfgEntry
CfgEntry
.1.3.6.1.4.1.738.1.5.112.1.1.1
prvtAlarmIDExternal and internal alarm index uniquely identifies this row. T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-contact sensor inputs and two dry-contact sensor outputs. An integer with supported range of values 1-6 for T5C-XG and 1-4 for T-Metro 200 ES. Index. Not-accessiblero
Integer32
.1.3.6.1.4.1.738.1.5.112.1.1.1.1
prvtSensorTypeSensor type. An enumeration with two values: input(1), output(2). T-Metro 200 ES platform has four dry-contacts sensor inputs. T5C-XG platform has four dry-contact sensor inputs and two dry-contact sensor outputs. Read-only.ro
Enumeration
.1.3.6.1.4.1.738.1.5.112.1.1.1.2
prvtNameName of alarm. An OCTET-STRING with max. 16 OCTETS. Default value null string. Read-writerw
OCTET STRING
.1.3.6.1.4.1.738.1.5.112.1.1.1.3
prvtDescriptionAlarm description. An OCTET-STRING with max. 64 OCTETS. Default value null string. Read-writerw
OCTET STRING
.1.3.6.1.4.1.738.1.5.112.1.1.1.4
prvtEnableStatusSenging alarms status. An enumeration with two values: enabled(1), disabled(2). Default value is disabled(2). Read-writerw
Enumeration
.1.3.6.1.4.1.738.1.5.112.1.1.1.5
prvtAlarmStatusAlarm status. An enumeration with two values: no-alarm(1), alarm(2). Default value is no-alarm(1). Read-only.ro
Enumeration
.1.3.6.1.4.1.738.1.5.112.1.1.1.6
prvtAlarmSeverityConfigured alarm severity. An enumeration with 4 values: info(1), minor(2), major(3) and critical(4). Default value is info(1). Read-writerw
Enumeration
.1.3.6.1.4.1.738.1.5.112.1.1.1.7
prvtPolarityConfigured polarity. An enumeration with 2 values: normally-opened(1), normally-closed(2). This object is only for T-Metro 200 ES platform. Default value is normally-opened(1). Read-writerw
Enumeration
.1.3.6.1.4.1.738.1.5.112.1.1.1.8
prvtLastChangeThe value of sysUpTime at the time of the last operational status change. TimeTicks. Read-onlyro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.738.1.5.112.1.1.1.9

More MIBs from BATM Advanced Communication

Browse all BATM Advanced CommunicationMIBs →
PRVT-QOS-MIB

SNMP MIB module

376 objects→
PRVT-HQOS-MIB

The PRVT-HQOS-MIB provides vendor-specific SNMP access to configure and monitor hierarchical Quality of Service (HQoS) parameters, including traffic class definitions, queue scheduling policies, and bandwidth allocation limits on network devices. This module enables granular control over packet prioritization, shaping, and policing mechanisms across multiple traffic levels to enforce service level agreements.

344 objects→
PRVT-MPLS-TE-MIB

The PRVT-MPLS-TE-MIB module enables the monitoring and management of MPLS Traffic Engineering Label Switched Paths (LSPs) by exposing RSVP-TE and Constraint-Based LDP tunnel attributes, including bandwidth reservations, explicit route objects, and LSP state transitions. It facilitates the collection of operational metrics such as tunnel setup status, resource utilization, and constraint violations to support network capacity planning and fault isolation within MPLS core infrastructures.

287 objects→
PRVT-ISIS-MIB

SNMP MIB module

251 objects→
PRVT-SWITCH-ACCESS-LIST-MIB

The PRVT-SWITCH-ACCESS-LIST-MIB module provides programmatic management of Layer 3 switch access control list (ACL) parameters, enabling the configuration and monitoring of packet filtering rules, rule ordering, and hit counters on private network switches.

230 objects→
PRVT-SWITCH-MIB

PRVT-SWITCH-MIB provides the management interface for private switch hardware parameters, enabling the monitoring of port states, traffic counters, and configuration attributes via SNMP. This module facilitates the collection of operational metrics required for switch performance analysis and fault isolation in private network environments.

216 objects→