Home/Catalog/PLEXCOM-MIB

PLEXCOM-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

242
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

242 total
Object Name
plexcom
OBJECT IDENTIFIER
.1.3.6.1.4.1.465
RFC-1215
Unknown
.1.3.6.1.4.1.465
plxPanicMesgTrapThe plxPanicMesgTrap trap is generated when the agent resets for a reason other than a normal hardware reset or restart condition. The plxSysPanicMesg variable contains a textual explanation for the reset, as saved in non-volatile memory.
TRAP-TYPE
.1.3.6.1.4.1.465.0.4
plxGenericHubTrapThe generic hub trap is sent when one of several changes occurs in the status of the agent. There are three conditions which may cause this: the addition or deletion of a group (usually a module) from the agent (or chassis), in which case the plxGroupType variable is returned, and changes in the autopartition or link states of a given port, in which case the plxPortAutoPartState or plxPortLinkState variables are returned, respectively.
TRAP-TYPE
.1.3.6.1.4.1.465.0.5
plxSecurityViolationTrapThe security violation trap is sent when an alarm occurs in the agent that indicates a configured security provision has been violated. In conjunture with the plxIntruderControlTable, this trap is sent when an non-allowed intruder source address is detected on a port. In this case, the plxIcCurrentSourceAddress variable is returned indicating the violating address on the affected port.
TRAP-TYPE
.1.3.6.1.4.1.465.0.6
plxNode
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1
plxAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1
plxStBridgeagent
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.1
plxStBridgesnmpd
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.1.1
plxPlexcomHub8091
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.1.1.4
plxPlexcomHub8039
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.1.1.5
plxPlexcomHub8029
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.1.1.6
plxPlexcomHub8093
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.1.1.7
plxRepeaterAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2
plxPlexcom8025
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.1
plxPlexcom8025SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.1.1
plxPlexcom8025SXT
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.1.2
plxPlexcomH8025SXT
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.1.3
plxPlexcomH8025SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.1.4
plxPlexcomS8025SXT
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.1.5
plxPlexcomS8025SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.1.6
plxPlexcomPlexSTACK
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.2
plxPlexcom4000i
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.2.1
plxPlexcom4000iR
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.2.2.2
plxSwitchAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.3
plxPlexcom5108
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.1.3.1
plxModule
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2
plxModuleUnknown
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.1
plxModule8010
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.2
plxModule8011
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.3
plxModule8023A
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.4
plxModule8024A
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.5
plxModule8024T
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.6
plxModule8026A
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.7
plxModule8026T
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.8
plxModule8029M
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.9
plxModule8091M
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.10
plxModule8023
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.11
plxModule8031
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.13
plxModule8031A
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.14
plxModule8033
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.15
plxModule8034
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.16
plxModule8033A
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.17
plxModule8024FO
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.24
plxModule8039M
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.32
plxModule8039S
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.33
plxModule8026FO
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.34
plxModule8408
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.35
plxModule8400FO
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.36
plxModule8032-R
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.43
plxModule8032-1P
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.45
plxModule8032-2P
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.47
plxModule8032-4P
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.51
plxModule8032-6P
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.55
plxModule2008SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.56
plxModule8035
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.58
plxModule8035STP
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.59
plxModule8036
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.60
plxModule8023SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.70
plxModule8012SX-1
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.71
plxModule8012SX-6
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.72
plxModule8024SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.73
plxModule8027SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.74
plxModule8091SXM
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.75
plxModule8029SX-3M
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.76
plxModule8029SX-3S
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.77
plxModule8025SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.78
plxModule8025SXT
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.79
plxModuleH8025SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.81
plxModuleS8025SXT
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.82
plxModuleS8025SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.83
plxModule8408FO
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.84
plxModule8012SX-2
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.85
plxModule8012SX-4
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.86
plxModule8026SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.88
plxModule8035SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.89
plxModuleP8035SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.90
plxModule8093SXM
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.91
plxModule8093SXS
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.92
plxModule8039SXM
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.93
plxModule8039SXS
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.1.2.94
plxFilterTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.2
plxFtConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.2.1
plxFtMaxAgeMaximum age of a filter table entry before it is deleted from the table. The value is multiplied by plxFtAgeTime (update timer interval) to form the timer value in seconds.rw
INTEGER
.1.3.6.1.4.1.465.2.1.1
plxFtMaxRemoveWhen the filter table is full and new entries need to be made, the oldest plxFtMaxRemove number of entries are removed.rw
INTEGER
.1.3.6.1.4.1.465.2.1.2
plxFtMaxFilterSize of the filter table.ro
INTEGER
.1.3.6.1.4.1.465.2.1.3
plxFtAgeTimeFilter table age timer interval. The filter entry age is incremented every plxFtAgeTime seconds.rw
INTEGER
.1.3.6.1.4.1.465.2.1.4
plxFtMaxPermMax number of permanent filter table entries. Setting this value to zero clears all permanent and dynamic entries from the filter table. Any other set is ignored.rw
INTEGER
.1.3.6.1.4.1.465.2.1.5
plxFtForwMBcastEnable or disable forwarding of broadcasts and multicasts.rw
Enumeration
.1.3.6.1.4.1.465.2.1.6
plxFtSecureModeEnable or disable 'secure' mode. In 'secure' mode the bridge does not learn filter table entries dynamically.rw
Enumeration
.1.3.6.1.4.1.465.2.1.7
plxFtEntry
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.2.2
plxFtAgeFilter table entry age. Instance is a six element object identifier representing the MAC address.rw
INTEGER
.1.3.6.1.4.1.465.2.2.1
plxFtDispFilter table entry disposition. Instance is a six element object identifier representing the MAC address.rw
Enumeration
.1.3.6.1.4.1.465.2.2.2
plxInterfaceErrors
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.3
plxIfeInBusErrBus read errors (Ethernet chip error).ro
Counter
.1.3.6.1.4.1.465.3.1
plxIfeInShortPktShort frames received.ro
Counter
.1.3.6.1.4.1.465.3.2
plxIfeInAlgErrorFrames received with bad alignment.ro
Counter
.1.3.6.1.4.1.465.3.3
plxIfeInBadSizeFrames received with bad length.ro
Counter
.1.3.6.1.4.1.465.3.4
plxIfeInOverflowReceive buffer overflow errors.ro
Counter
.1.3.6.1.4.1.465.3.5
plxIfeInCRCErrFrames received with CRC errors.ro
Counter
.1.3.6.1.4.1.465.3.6
plxIfeOutCol16Frames discarded due to excess collisions.ro
Counter
.1.3.6.1.4.1.465.3.7
plxIfeOutColTransmit collisions.ro
Counter
.1.3.6.1.4.1.465.3.8
plxIfeOutShortPktShort packets transmitted (Ethernet chip error).ro
Counter
.1.3.6.1.4.1.465.3.9
plxIfeOutUnderflowTransmit buffer underflow.ro
Counter
.1.3.6.1.4.1.465.3.10
plxIfeOutBusErrBus write errors (Ethernet chip error).ro
Counter
.1.3.6.1.4.1.465.3.11
plxForwardCounters
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.4
plxFcInOctetsReceived bytes.ro
Counter
.1.3.6.1.4.1.465.4.1
plxFcInPktsReceived frames.ro
Counter
.1.3.6.1.4.1.465.4.2
plxFcInNUcastPktsReceived multicast and broadcast frames.ro
Counter
.1.3.6.1.4.1.465.4.3
plxFcForwOctetsForwarded bytes.ro
Counter
.1.3.6.1.4.1.465.4.4
plxFcForwPktsForward frames.ro
Counter
.1.3.6.1.4.1.465.4.5
plxFcFiltOctetsFiltered bytes.ro
Counter
.1.3.6.1.4.1.465.4.6
plxFcFiltPktsFiltered frames.ro
Counter
.1.3.6.1.4.1.465.4.7
plxSystemCounters
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.5
plxSysMemFreeAmount of memory free of a particular size. Instance is the memory block size.ro
Counter
.1.3.6.1.4.1.465.5.1
plxSysMemAllocFailNumber of times an allocation of a particular size was denied due to no buffers. Instance is the buffer size.ro
Counter
.1.3.6.1.4.1.465.5.2
plxSysMemTotAllocFailTotal number of memory allocation failures.ro
Counter
.1.3.6.1.4.1.465.5.3
plxSysMemFreeFailCount of deallocation failures due to inconsistent function arguments.ro
Counter
.1.3.6.1.4.1.465.5.4
plxSysMemAllocTooBigNumber of times a memory allocation was denied because the buffer size was too large.ro
Counter
.1.3.6.1.4.1.465.5.5
plxSysTimeToResetAmount of time (seconds) until the agent will reset. Setting this to any non-zero value will cause a reset.rw
Counter
.1.3.6.1.4.1.465.5.6
plxSysPanicMesgThe message printed on the console before the last system crash, or a probable cause of the last crash.ro
DisplayString
.1.3.6.1.4.1.465.5.7
plxSysResetCountNumber of times the device has been reset (not including power recycles).ro
Counter
.1.3.6.1.4.1.465.5.8
plxSysSoftwareVersionThe version of software currently functioning in the system.ro
DisplayString
.1.3.6.1.4.1.465.5.10
plxSpanningTree
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.6
plxStBridge
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.6.1
plxStBrNamePrintable bridge name.rw
OCTET STRING
.1.3.6.1.4.1.465.6.1.1
plxStBrIdentBridge identifier (8 bytes).rw
OCTET STRING
.1.3.6.1.4.1.465.6.1.2
plxStBrMaxAgeBridge default 802.1 Max Age parameter.rw
INTEGER
.1.3.6.1.4.1.465.6.1.3
plxStBrHelloTimeBridge default 802.1 Hello Time parameter.rw
INTEGER
.1.3.6.1.4.1.465.6.1.4
plxStBrForwDelayBridge default 802.1 Forward Delay parameter.rw
INTEGER
.1.3.6.1.4.1.465.6.1.5
plxStBrIsRootFlag indicating if the bridge is the root.ro
Enumeration
.1.3.6.1.4.1.465.6.1.6
plxStBrIsDesigFlag indicating if the bridge is designated for a LAN.ro
Enumeration
.1.3.6.1.4.1.465.6.1.7
plxStBrSpanAddrMAC address used by the Spanning Tree Protocol for sending and receiving Config and Topology change frames.ro
OCTET STRING
.1.3.6.1.4.1.465.6.1.8
plxStBrPriority802.1 Bridge Priority parameter.rw
INTEGER
.1.3.6.1.4.1.465.6.1.9
plxStBrSTPDisabledFlag used to enable or disable 802.1 Spanning Tree Protocol operation.rw
Enumeration
.1.3.6.1.4.1.465.6.1.10
plxStRoot
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.6.2
plxStRtIdentRoot 802.1 Bridge Identifier.ro
OCTET STRING
.1.3.6.1.4.1.465.6.2.1
plxStRtCostRoot path cost.ro
INTEGER
.1.3.6.1.4.1.465.6.2.2
plxStRtPortRoot port number.ro
Enumeration
.1.3.6.1.4.1.465.6.2.3
plxStRtMaxAgeRoot 802.1 Max Age parameter.ro
INTEGER
.1.3.6.1.4.1.465.6.2.4
plxStRtHelloTimeRoot 802.1 Hello Time parameter.ro
INTEGER
.1.3.6.1.4.1.465.6.2.5
plxStRtForwDelayRoot 802.1 Forward Delay parameter.ro
INTEGER
.1.3.6.1.4.1.465.6.2.6
plxStPort
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.6.3
plxStPrtState802.1 Port State.rw
Enumeration
.1.3.6.1.4.1.465.6.3.1
plxStPrtCost802.1 Port cost parameter.ro
INTEGER
.1.3.6.1.4.1.465.6.3.2
plxStPrtIsDesigFlag indicating if this port is designated.ro
Enumeration
.1.3.6.1.4.1.465.6.3.3
plxStPrtIsRootFlag indicating if this is the root port.ro
Enumeration
.1.3.6.1.4.1.465.6.3.4
plxStPrtDesigRoot802.1 Bridge Identifier of the Designated Root for this port.ro
OCTET STRING
.1.3.6.1.4.1.465.6.3.5
plxStPrtDesigCostDesignated cost for this port.ro
INTEGER
.1.3.6.1.4.1.465.6.3.6
plxStPrtDesigBridgeDesignated bridge for this port.ro
OCTET STRING
.1.3.6.1.4.1.465.6.3.7
plxStPrtDesigPortDesignated port.ro
INTEGER
.1.3.6.1.4.1.465.6.3.8
plxStPrtPriorityPort priority.ro
INTEGER
.1.3.6.1.4.1.465.6.3.9
plxSpanTreeStats
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.6.4
plxStsTopoChangesTopology changes detected.ro
Counter
.1.3.6.1.4.1.465.6.4.1
plxStsConfigTimeoutConfiguration timeouts.ro
Counter
.1.3.6.1.4.1.465.6.4.2
plxStsPortDisableCount of port disables.ro
Counter
.1.3.6.1.4.1.465.6.4.3
plxStsPortEnableCount of port enables.ro
Counter
.1.3.6.1.4.1.465.6.4.4
plxStsInBadLen802.1 frames received with bad length.ro
Counter
.1.3.6.1.4.1.465.6.4.5
plxStsInUnknown802.1 frames received with bad frame type.ro
Counter
.1.3.6.1.4.1.465.6.4.6
plxStsIn8021Man802.1 Management frames received (discarded by bridge).ro
Counter
.1.3.6.1.4.1.465.6.4.7
plxStsInConfig802.1 Config frames received.ro
Counter
.1.3.6.1.4.1.465.6.4.8
plxStsInTopoChg802.1 Topology change notification frames received.ro
Counter
.1.3.6.1.4.1.465.6.4.9
plxStsOutConfig802.1 Config frames sent.ro
Counter
.1.3.6.1.4.1.465.6.4.10
plxStsOutTopoChg802.1 Topology change notification frames sent.ro
Counter
.1.3.6.1.4.1.465.6.4.11
plxFilterRange
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.7
plxFrNumRangeThe maximum number of filter range table entries when read (GET). Set to zero to delete all filter range table entries. A set with any other value is ignored.rw
INTEGER
.1.3.6.1.4.1.465.7.1
plxFrEntryFilter range table entry. Instance is the range table number (1 to plxFrNumRange). Each entry has the following format: uchar frLowDest[6]; /* low bound of destination */ uchar frLowSrc[6]; /* low bound of source */ ushort frLowType; /* low bound of type */ uchar frHighDest[6]; /* high bound of destination */ uchar frHighSrc[6]; /* high bound of source */ ushort frHighType; /* high bound of type */ uchar frflag; /* disposition flag */ unchar frfill; /* round up size */ The LowType and HighType are in network byte order (Motorola 68K). The flag is one of the bridge filter table disposition values.rw
OCTET STRING
.1.3.6.1.4.1.465.7.2
plxPlexcomProp
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.9
plxPlexAsyncPlexcom 8090 proprietary management frame. Instance is '0'. This info is available in published form by using the 'plxHub' variables.rw
OCTET STRING
.1.3.6.1.4.1.465.9.1
plxPlexStatStatus of Plexcom 8090 management module as deduced by response to poll. Instance is '0'.ro
Enumeration
.1.3.6.1.4.1.465.9.2
plxPlexBkBitsPlexcom 8091 proprietary management frame. Instance is '0'. This info is available in a decoded form by using the 'plxHub' variables. Structure for SET (size 104): #define MAX_SLOTS 13 #define SLOT_INFO_SIZE 8 char module_set_prop[MAX_SLOTS][SLOT_INFO_SIZE] Structure for GET (size 208): char module_set_prop[MAX_SLOTS][SLOT_INFO_SIZE] char module_get_prop[MAX_SLOTS][SLOT_INFO_SIZE] Contents of 'module_set_prop' and 'module_get_prop' is proprietary.rw
OCTET STRING
.1.3.6.1.4.1.465.9.3
plxPlexBkDefPlexcom module definition. Instance is module type, 'plxGroupType'.rw
OCTET STRING
.1.3.6.1.4.1.465.9.4
plxHub
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.10
plxHmBasicHubTableTable containing global info for a hub.
SEQUENCE OF PlxHmBasicHubEntry
.1.3.6.1.4.1.465.10.1
plxHmBasicHubEntry
PlxHmBasicHubEntry
.1.3.6.1.4.1.465.10.1.1
plxHubBasicIDHub ID (MAC address of management port).ro
OCTET STRING
.1.3.6.1.4.1.465.10.1.1.1
plxHubGroupCapacityThe number of slots available in the hub.ro
INTEGER
.1.3.6.1.4.1.465.10.1.1.2
plxHubGroupMapA sequence of bytes defining which hub slots are populated with groups (cards or groups). The first byte of the sequence represents slot 1, the second byte slot 2, etc. A value of '1' indicates presence of a group and '0' indicates an absence.ro
OCTET STRING
.1.3.6.1.4.1.465.10.1.1.3
plxHubGroupCountThe number of groups currently active in the hub.ro
INTEGER
.1.3.6.1.4.1.465.10.1.1.4
plxHmBasicGroupTableA table of info for each hub module.
SEQUENCE OF PlxHmBasicGroupEntry
.1.3.6.1.4.1.465.10.2
plxHmBasicGroupEntry
PlxHmBasicGroupEntry
.1.3.6.1.4.1.465.10.2.1
plxGroupHubBasicIDHub identifier (MAC address of management port).ro
OCTET STRING
.1.3.6.1.4.1.465.10.2.1.1
plxGroupBasicIDGroup identifier (module or slot number). First (left/bottom) slot is 1.ro
Enumeration
.1.3.6.1.4.1.465.10.2.1.2
plxGroupNumberOfPortsNumber of ports in this group.ro
INTEGER
.1.3.6.1.4.1.465.10.2.1.3
plxGroupTypeGroup (module) type.ro
Enumeration
.1.3.6.1.4.1.465.10.2.1.4
plxGroupAutoPartStateA sequence of bytes defining the auto-partition state of each port. The first byte corresponds to port 1, the second byte to port 2, etc. The value of each element is of the same type as the 'plxPortAutoPartState' variable.ro
OCTET STRING
.1.3.6.1.4.1.465.10.2.1.5
plxGroupAdminStateA sequence of bytes defining the enable state of each port. The first byte corresponds to port 1, the second byte to port 2, etc. The value of each element is of the same type as the 'plxPortAdminState' variable.rw
OCTET STRING
.1.3.6.1.4.1.465.10.2.1.6
plxGroupCascadeConfigAn integer defining the configuration control of bussed cascade networks. For PlexNet SX products, this variable is only applicable to 23SX, 24SX, 27SX, etc. modules, and not the 91SX, 29SX, etc. modules. A value of '1' is returned for modules which don't support the variable. A '2' indicates local configuration, meaning the hardware switch has been set on the board to control the cascade network based on hardware switches, and to disallow setting of the cascade network by remote management. A value of '3' indicates remote configuration, meaning the hardware switch is set to allow remote configuration of the cascade networks.ro
Enumeration
.1.3.6.1.4.1.465.10.2.1.7
plxGroupCascadeNetworkA sequence of bytes defining the selected bussed cascade network. A value of '9' indicates no cascade network selected. This can be SET only on device types. A value of '1' through '4' indicates the selected cascade network. A value of '8' (SET only) is used to set the device to use its hardware switches to select the cascade network. For PlexNet 8091SX and 8029SX type modules, the first byte represents port 1's internal network and the second byte port 2's internal network. A value of '10' (hex a) is returned for any module which does not support bussed cascade networks.rw
OCTET STRING
.1.3.6.1.4.1.465.10.2.1.8
plxGroupLinkStateA sequence of bytes defining the link state of each port. The first byte corresponds to port 1, the second byte to port 2, etc. The value of each element is of the same type as the 'plxPortLinkState' variable.ro
OCTET STRING
.1.3.6.1.4.1.465.10.2.1.9
plxGroupLinkPartTrapEnableA sequence of bytes defining the enabling state for generation of link and partition change traps from each port. The first byte corresponds to port 1, the second byte to port 2, etc. A value of '2' indicates trap generation for the corresponding port is disabled and a value of '3' indicates enabled.rw
OCTET STRING
.1.3.6.1.4.1.465.10.2.1.10
plxGroupNetworkSegmentThe network segment that the corresponding group is currently operating on. This is the 'repeater' number used when accessing statistical information from the agent via other standard MIBs. The value '255' (hex ff) is returned if not applicable.ro
OCTET STRING
.1.3.6.1.4.1.465.10.2.1.11
plxGroupChassisNoThe number or id of the physical enclosure that the corresponding group is operating in. This variable maps a logical grouping of ports into a physical grouping. The value '1' is returned for systems in which all groups reside in the same physical enclosure.ro
INTEGER
.1.3.6.1.4.1.465.10.2.1.12
plxHmBasicPortTableA table of info for the ports within a hub module. The instance of each element is 'GroupID.PortID'. For example, the Admin State of port 3 of slot 2 is 'plxPortAdminState.2.3'.
SEQUENCE OF PlxHmBasicPortEntry
.1.3.6.1.4.1.465.10.3
plxHmBasicPortEntry
PlxHmBasicPortEntry
.1.3.6.1.4.1.465.10.3.1
plxPortHubBasicIDHub identifier (MAC address of management port).ro
OCTET STRING
.1.3.6.1.4.1.465.10.3.1.1
plxPortGroupBasicIDGroup identifier (module or slot number). First slot is 1.ro
Enumeration
.1.3.6.1.4.1.465.10.3.1.2
plxPortBasicIDPort identifier (number). First port is the leftmost or topmost port of a card and is number 1.ro
Enumeration
.1.3.6.1.4.1.465.10.3.1.3
plxPortMauTypePort physical interface type.ro
Enumeration
.1.3.6.1.4.1.465.10.3.1.4
plxPortAdminStatePort enable state.rw
Enumeration
.1.3.6.1.4.1.465.10.3.1.5
plxPortAutoPartStatePort auto-partition state.ro
Enumeration
.1.3.6.1.4.1.465.10.3.1.6
plxPortLinkStatePort link state.ro
Enumeration
.1.3.6.1.4.1.465.10.3.1.7
plxSystemAdmin
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.11
plxSysAdmCommunityTableA table of SNMP community name entries allowing different levels of SNMP access. A maximum of 5 entries are allowed.
SEQUENCE OF PlxSysAdmCommunityEntry
.1.3.6.1.4.1.465.11.1
plxSysAdmCommunityEntryAn entry in the SNMP community table.
PlxSysAdmCommunityEntry
.1.3.6.1.4.1.465.11.1.1
plxCommunityIndexA unique index for this community table entry.ro
INTEGER
.1.3.6.1.4.1.465.11.1.1.1
plxCommunityNameThe community name to which this entry grants access. This string must be unique among the community names defined in all entries of this table. A community name entry does not become effective until the corresponding plxCommunityAccess variable is set to a value other than invalid(100).rw
DisplayString
.1.3.6.1.4.1.465.11.1.1.2
plxCommunityAccessThe access level for the community name. This variable must be set to a value of readOnly(1), readWrite(2), or superUser(3) for the corresponding plxCommunityName variable in the table to be valid. A value of readOnly(1) allows 'GET' only privleges on all MIB objects except the community table. A value of readWrite(2) allows 'GET' and 'SET' privleges on all MIB objects except the community table. A value of superUser(3) allows 'GET' and 'SET' privleges on all MIB objects including the community table. The value invalid(100) is returned for invalid table entries. A 'SET' with this value clears the entry from the table.rw
Enumeration
.1.3.6.1.4.1.465.11.1.1.3
plxSysAdmDownload
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.11.2
plxDownloadFileNameName of the file to download via the network to Flash.rw
DisplayString
.1.3.6.1.4.1.465.11.2.1
plxDownloadServerAddressThe IP address of the server that contains the file to download.rw
DisplayString
.1.3.6.1.4.1.465.11.2.2
plxDownloadActionSetting this object to download(2) initiates a download of system software. The variables plxDownloadServerAddress and plxDownloadFileName must be first set before starting a download. The agent will return the value download(2) when a download is currently in progress. Setting this object to noDownload(1) has no effect. The agent will return this value unless a download is in progress.rw
Enumeration
.1.3.6.1.4.1.465.11.2.3
plxDownloadStatusThe status of the last download performed. The value downloadSuccess(1) indicates a successful download, and that the device is operating from the downloaded firmware. noDownloadOccurred(2) is returned if no firmware download has yet been performed. If Flash EPROM is not present on the board or is bad, badFlash(3) is returned. The value badServerAddress(4) indicates the IP address of the server configured by the plxDownloadServerAddress variable is bad. badFile(5) indicates the downloaded file had a bad checksum or is corrupt. The value downloadInProgress(14) indicates that a download is currently being performed. The remaining values indicate a TFTP protocol specific failure during the most recent download, and are the error codes defined in RFC 783, offset by six.ro
Enumeration
.1.3.6.1.4.1.465.11.2.4
plxSysAdmTrapTable
SEQUENCE OF PlxSysAdmTrapEntry
.1.3.6.1.4.1.465.11.3
plxSysAdmTrapEntry
PlxSysAdmTrapEntry
.1.3.6.1.4.1.465.11.3.1
plxTrapIndexThis object identifies the entry within the trap table.ro
INTEGER
.1.3.6.1.4.1.465.11.3.1.1
plxTrapStandardEnableEnable or disable generation of standard traps for this entry.rw
Enumeration
.1.3.6.1.4.1.465.11.3.1.4
plxTrapPlexcomEnableEnable or disable Plexcom specific trap generation for this entry.rw
Enumeration
.1.3.6.1.4.1.465.11.3.1.5
plxTrapRepeaterEnableEnable or disable Repeater MIB specific trap generation for this entry.rw
Enumeration
.1.3.6.1.4.1.465.11.3.1.6
plxTrapNovellEnableEnable or disable Novell HMI MIB specific trap generation for this entry.rw
Enumeration
.1.3.6.1.4.1.465.11.3.1.7
plxSysAdmMibControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.11.4
plxMcZeroStatCountersZero statistical counters maintained by the managed device. This zeros the port- and network-level performance stats maintained in all MIBs supported by the device. The variable should be set to 'zeroCounters' to clear statistical entries. A value of 'noZero' is returned when this variable is read.rw
Enumeration
.1.3.6.1.4.1.465.11.4.1
plxMcNetworkSelectRptrMibSelect the 'repeater number' that the information in the Repeater MIB on the managed device represents. This variable is used for agents which manage multiple repeaters.rw
INTEGER
.1.3.6.1.4.1.465.11.4.2
plxMcNetworkSelectRmonMibSelect the 'repeater number' that the information in the RMON MIB on the managed device represents. This variable is used for agents which manage multiple repeaters.rw
INTEGER
.1.3.6.1.4.1.465.11.4.3
plxSecurity
OBJECT IDENTIFIER
.1.3.6.1.4.1.465.12
plxIntruderControlGroupTableA table of parameters for configuring software-controlled intruder detection for groups of ports.
SEQUENCE OF PlxIntruderControlGroupEntry
.1.3.6.1.4.1.465.12.1
plxIntruderControlGroupEntryAn entry in the intruder detection group table.
PlxIntruderControlGroupEntry
.1.3.6.1.4.1.465.12.1.1
plxIcGroupGroupIndexA unique group index for which this intruder control table entry represents.ro
INTEGER
.1.3.6.1.4.1.465.12.1.1.1
plxIcGroupAuthorizationTypeThe authorization level of the intruder detection on the corresponding group of ports. If set to singleUser(2) (the initial default), alarms will be triggered when more than one source address is detected on a given port. If set to noUser(1), no users are allowed on any port, and an alarm will be triggered if any traffic is generated on a port.rw
Enumeration
.1.3.6.1.4.1.465.12.1.1.2
plxIcGroupAlarmActionThe action to be taken when an alarm occurs on any port in the corresponding group. If this variable is set to trapOnly(2), the initial default, an SNMP trap will be generated when an intruder detect alarm occurs. If set to disableOnly(3), the port will be disabled when an alarm occurs. If set to trapAndDisable(4), both a trap will be generated and the port will be disabled. If set to none(1), no action will be taken.rw
Enumeration
.1.3.6.1.4.1.465.12.1.1.3
plxIcGroupAuthorizedAddressModeThe method by which the plxIcAuthorizedSourceAddress variable for the corresponding port should be configured. If this variable is set to autoLearn(1), the initial default, the allowed single source address on the port will be configured automatically by the address of the next valid packet on that port. If set to useAuthorized(2), the address as configured by an SNMP SET operation on the plxIcAuthorizedSourceAddress variable will be used.rw
Enumeration
.1.3.6.1.4.1.465.12.1.1.4
plxIcGroupDetectionStatusThe current status of the intruder detection on the corresponding port. The initial default for all ports is inactive(1), meaning that intruder detection is not active on the port. If set to active(2), intruder detection is enabled, and this value will then also be returned for an SNMP GET operation. If an alarm is generated, this variable will take on the value triggered(3). A set with the value active(2) will clear the triggered condition back to active. Intruder detection on the port is effectively still active in the triggered condition. The value triggered(3) is illegal for a SET operation.rw
Enumeration
.1.3.6.1.4.1.465.12.1.1.5
plxIntruderControlTableA table of parameters for configuring software-controlled intruder detection.
SEQUENCE OF PlxIntruderControlEntry
.1.3.6.1.4.1.465.12.2
plxIntruderControlEntryAn entry in the intruder detection table.
PlxIntruderControlEntry
.1.3.6.1.4.1.465.12.2.1
plxIcGroupIndexA unique group index for which this intruder control table entry represents.ro
INTEGER
.1.3.6.1.4.1.465.12.2.1.1
plxIcPortIndexA unique port index for which this intruder control table entry represents.ro
INTEGER
.1.3.6.1.4.1.465.12.2.1.2
plxIcAuthorizationTypeThe authorization level of the intruder detection on the corresponding port. If set to singleUser(2) (the initial default), an alarm will be triggered when more than one source address is detected on the port. If set to noUser(1), no users are allowed on the port, and an alarm will be triggered if any traffic is generated on the port.rw
Enumeration
.1.3.6.1.4.1.465.12.2.1.3
plxIcAlarmActionThe action to be taken when an alarm occurs on the corresponding port. If this variable is set to trapOnly(2), the initial default, an SNMP trap will be generated when an intruder detect alarm occurs. If set to disableOnly(3), the port will be disabled when an alarm occurs. If set to trapAndDisable(4), both a trap will be generated and the port will be disabled. If set to none(1), no action will be taken.rw
Enumeration
.1.3.6.1.4.1.465.12.2.1.4
plxIcAuthorizedAddressModeThe method by which the plxIcAuthorizedSourceAddress variable for the corresponding port should be configured. If this variable is set to autoLearn(1), the initial default, the allowed single source address on the port will be configured automatically by the address of the next valid packet on that port. If set to useAuthorized(2), the address as configured by an SNMP SET operation on the plxIcAuthorizedSourceAddress variable will be used.rw
Enumeration
.1.3.6.1.4.1.465.12.2.1.5
plxIcAuthorizedSourceAddressThe current authorized source address allowed by intruder detection on the corresponding port. This variable is only valid if the plxIcAuthorizationType variable for the port is singleUser(2). This variable must be configured if the plxIcAuthorizedAddressMode variable is set to useAuthorized. If plxIcAuthorizedAddressMode is set to autoLearn, the authorized source address will be automatically configured to be the source address of the last valid packet that was generated from the port (or the next valid packet if the port has had no traffic) after setting the plxIcDetectionStatus variable to active(2).rw
OCTET STRING
.1.3.6.1.4.1.465.12.2.1.6
plxIcCurrentSourceAddressThe source address of the last valid packet that was generated on the corresponding port. If an alarm was generated on the port and the port was disabled based on the setting of plxIcAlarmAction, this variable will contain the source address of the intruding device.ro
OCTET STRING
.1.3.6.1.4.1.465.12.2.1.7
plxIcDetectionStatusThe current status of the intruder detection on the corresponding port. The initial default for all ports is inactive(1), meaning that intruder detection is not active on the port. If set to active(2), intruder detection is enabled, and this value will then also be returned for an SNMP GET operation. If an alarm is generated, this variable will take on the value triggered(3). A set with the value active(2) will clear the triggered condition back to active. Intruder detection on the port is effectively still active in the triggered condition. The value triggered(3) is illegal for a SET operation.rw
Enumeration
.1.3.6.1.4.1.465.12.2.1.8
PLEXCOM-MIB - SNMP MIB Reference | MIBs Explorer