picaPrivateMib.1.3.6.1.4.1.35098
35
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
35 total| Object Name |
|---|
picaPrivateMibThe MIB module to manage Pica8's Pronto product. MODULE-IDENTITY .1.3.6.1.4.1.35098 |
hostStatusGroup OBJECT IDENTIFIER .1.3.6.1.4.1.35098.1 |
cpuUsageThe usage of CPU, the output format is integer.ro INTEGER .1.3.6.1.4.1.35098.1.1 |
totalPhyMemoryThe total physical memory size, the output format is string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.35098.1.2 |
usedPhyMemoryThe used physical memory size, the output format is string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.35098.1.3 |
freePhyMemoryThe free physical memory size, the output format is string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.35098.1.4 |
switchTemperatureThe temperature of switch, the output format is integer.ro INTEGER .1.3.6.1.4.1.35098.1.5 |
cpuTemperatureThe teperature of CPU, the output format is integer.ro INTEGER .1.3.6.1.4.1.35098.1.6 |
switchChipTemperatureThe teperature of switch chip, the output format is integer.ro INTEGER .1.3.6.1.4.1.35098.1.7 |
sfpstatusTableA list of sfp moudule status entries. SEQUENCE OF SfpstatusEntry .1.3.6.1.4.1.35098.1.8 |
sfpstatusEntryAn entry containing all sfp module stauts SfpstatusEntry .1.3.6.1.4.1.35098.1.8.1 |
sfpIndexThe port number of interface.ro INTEGER .1.3.6.1.4.1.35098.1.8.1.1 |
sfpVendorNameThe vendor name of sfp ransceiver transfer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.35098.1.8.1.2 |
sfpSerialNumberThe serial number of sfp ransceiver transfer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.35098.1.8.1.3 |
sfpTempThe temperature of sfp ransceiver transfer.ro Integer32 .1.3.6.1.4.1.35098.1.8.1.4 |
sfpVoltageThe voltage of sfp ransceiver transfer.ro Integer32 .1.3.6.1.4.1.35098.1.8.1.5 |
sfpBiasThe bias current of sfp ransceiver transfer.ro Integer32 .1.3.6.1.4.1.35098.1.8.1.6 |
sfpTxPowerThe Tx power of sfp ransceiver transfer(dBm).ro Integer32 .1.3.6.1.4.1.35098.1.8.1.7 |
sfpRxPowerThe Rx power of sfp ransceiver transfer(dBm).ro Integer32 .1.3.6.1.4.1.35098.1.8.1.8 |
sfpTypeThe type of sfp ransceiver transfer(dBm).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.35098.1.8.1.9 |
rpsustatusTableA list of Redundancy power supply unit(RPSU) status entries. SEQUENCE OF RpsustatusEntry .1.3.6.1.4.1.35098.1.9 |
rpsustatusEntryAn entry containing all Redundancy power supply unit(RPSU) stauts. RpsustatusEntry .1.3.6.1.4.1.35098.1.9.1 |
rpsuIndexThe Redundancy power supply unit(RPSU) number.ro INTEGER .1.3.6.1.4.1.35098.1.9.1.1 |
rpsuStatusThe status of Redundancy power supply unit(RPSU). 1: The Redundancy power supply unit(RPSU) is plugged in. 0: The Redundancy power supply unit(RPSU) is plugged out.ro INTEGER .1.3.6.1.4.1.35098.1.9.1.2 |
switchConfigGroup OBJECT IDENTIFIER .1.3.6.1.4.1.35098.2 |
tftpConfigFilePathIf the tftp path of defined config file is set, the configurations included in the config file are also applied meanwhile.rw OCTET STRING .1.3.6.1.4.1.35098.2.0 |
tftpBatchFilePathIf the tftp path of a command batch file is set, the present configurations will changed depending on the execution of the command in the batch file.rw OCTET STRING .1.3.6.1.4.1.35098.2.1 |
picaConformance OBJECT IDENTIFIER .1.3.6.1.4.1.35098.20 |
picaGroups OBJECT IDENTIFIER .1.3.6.1.4.1.35098.20.1 |
picaBasicGroupThese objects are required for pica private mib. Unknown .1.3.6.1.4.1.35098.20.1.1 |
picasfpGroupThese objects are required for pica private mib. Unknown .1.3.6.1.4.1.35098.20.1.2 |
picarpsuGroupThese objects are required for pica private mib. Unknown .1.3.6.1.4.1.35098.20.1.3 |
picaConfigGroupThese objects are required for pica private mib. Unknown .1.3.6.1.4.1.35098.20.1.4 |
picaCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.35098.20.2 |
picaComplianceThe compliance statement Unknown .1.3.6.1.4.1.35098.20.2.1 |