phihong OBJECT IDENTIFIER .1.3.6.1.4.1.24852 |
poeProduct OBJECT IDENTIFIER .1.3.6.1.4.1.24852.2 |
poeProductsPartthe POE controller Part.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.24852.2.1 |
poeSystem OBJECT IDENTIFIER .1.3.6.1.4.1.24852.2.2 |
poeSystemActionHubResetReset the POE controller.rw Enumeration .1.3.6.1.4.1.24852.2.2.1 |
poeSystemActionHubRestoreFactoryDefaultRestore Factory Default to flash. resetpassword means when users forget the password,they can use this entry, and all of the snmp module parameters will be set to default values.rw Enumeration .1.3.6.1.4.1.24852.2.2.2 |
poeSystemActionHubSaveConfigurationSave the POE parameters to flashrw Enumeration .1.3.6.1.4.1.24852.2.2.3 |
poeSystemAllPortPowerEnableEnables power supply in all port. Setting this object at a value enable(2) enables power and detection mechanism for all port. Setting this object at a value disable(1) disables power for all port.rw Enumeration .1.3.6.1.4.1.24852.2.2.4 |
poeSystemHWVersionSystem hardware version for the Main boardro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.24852.2.2.6 |
poeSystemNumberOfChannelNumber of ports in the systemro INTEGER .1.3.6.1.4.1.24852.2.2.7 |
poeSystemProductPartNumberSystem Part Number for PowerHubro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.24852.2.2.8 |
poeSystemFirmwareVersionSystem firmware version for the POEro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.24852.2.2.10 |
poeSystemDescriptionSystem Description 10 charactersrw DisplayString .1.3.6.1.4.1.24852.2.2.11 |
poeSystemConsumptionPowerMeasured usage power expressed in Watts.ro INTEGER UNITS "Watts" .1.3.6.1.4.1.24852.2.2.12 |
poeSystemControlACPowerdescribes the maximum available power in Watts to be supplied by the AC backup source to this device.rw INTEGER UNITS "Watts" .1.3.6.1.4.1.24852.2.2.13 |
poeSystemControlDCPowerdescribes the maximum available power in Watts to be supplied by the DC backup source to this device.rw INTEGER UNITS "Watts" .1.3.6.1.4.1.24852.2.2.14 |
poeSystemControlBothPowerdescribes the maximum available power in Watts to be supplied by Both AC and DC backup source to this device.rw INTEGER UNITS "Watts" .1.3.6.1.4.1.24852.2.2.15 |
poeSystemParameters1st char:Knokoff enable,2nd char:AC Disconnect enable,3th char:Disable Power Managementrw DisplayString .1.3.6.1.4.1.24852.2.2.16 |
poeSystemSnmpVersionThe software version for the SNMP devicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.24852.2.2.17 |
poeSystemPerPortPowerEnableEnables power supply in all port. Setting this object at a value enable(2) enables power and detection mechanism for all port. Setting this object at a value disable(1) disables power for all port.rw DisplayString .1.3.6.1.4.1.24852.2.2.18 |
poeSystemStatusThe status of the POE.ro Enumeration .1.3.6.1.4.1.24852.2.2.19 |
poePortTable SEQUENCE OF PoePortEntry .1.3.6.1.4.1.24852.2.3 |
poePortEntryport entry containing data regarding a particular port PoePortEntry .1.3.6.1.4.1.24852.2.3.1 |
poePortIndexA unique value for each port.ro INTEGER .1.3.6.1.4.1.24852.2.3.1.1 |
poePortPowerEnableEnables power supply on this port. Setting this object at a value enable(2) enables power and detection mechanism for this port. Setting this object at a value disable(1) disables power for this port.rw Enumeration .1.3.6.1.4.1.24852.2.3.1.2 |
poePortControlMaxPowerThis command specifies the max power in [mWatts] to that port. IF you set this value it will take out this port from the auto mode. The value MUST be more then 0rw INTEGER UNITS "mWatts" .1.3.6.1.4.1.24852.2.3.1.3 |
poePortDescriptionPort Description 10 charactersrw DisplayString .1.3.6.1.4.1.24852.2.3.1.6 |
poePortDetectionStatusPort Detection, show the detection status of each portro Enumeration .1.3.6.1.4.1.24852.2.3.1.7 |
poePortPowerClassificationsPort Power Classifications, show the classification of each portro Enumeration .1.3.6.1.4.1.24852.2.3.1.8 |
poePortPowerDetectionControlPort Power Detection Control, enable or disable the Power Limit for Managementrw Enumeration .1.3.6.1.4.1.24852.2.3.1.9 |
poePortPowerPriorityPort Power Priority, show the priority of each portrw Enumeration .1.3.6.1.4.1.24852.2.3.1.10 |
poePortPowerPort Actual Power (in mWattes).ro INTEGER UNITS "mWattes" .1.3.6.1.4.1.24852.2.3.1.11 |
poePortVoltagePort Voltage (in dVoltage).ro DisplayString UNITS "dVoltage" .1.3.6.1.4.1.24852.2.3.1.12 |
poePortCurrentPort Current (in mAmps).ro INTEGER UNITS "mAmps" .1.3.6.1.4.1.24852.2.3.1.13 |
poePortResistancePort Resistance (in ohms).ro INTEGER UNITS "ohms" .1.3.6.1.4.1.24852.2.3.1.14 |
poePortFlags1st char:classification(0-3),2nd char:Port bypass detection enable,3th char:Port bypass classifiation enable,4th cahr:Port bypass powerup enable,5th char:Port bypass sampling enable.ro DisplayString .1.3.6.1.4.1.24852.2.3.1.15 |
poePortBypassFlags1st char:Port bypass detection enable,2nd char:Port bypass classifiation enable,3th cahr:Port bypass powerup enable,4th char:Port bypass sampling enable.rw DisplayString .1.3.6.1.4.1.24852.2.3.1.16 |
poePortUseClassificationforPowerLimitUse Port classification for power limit , enable or disable the Port classification for power limit.rw Enumeration .1.3.6.1.4.1.24852.2.3.1.17 |
poePortLegacyDetectionUse Port legacy detection , enable or disable the Port legacy detection.rw Enumeration .1.3.6.1.4.1.24852.2.3.1.18 |
poeTrapsControlTableA table of objects that display and control the Traps on a PSM device. SEQUENCE OF PoeTrapsControlEntry .1.3.6.1.4.1.24852.2.4 |
poeTrapsControlEntryA set of objects that control the Trap events. PoeTrapsControlEntry .1.3.6.1.4.1.24852.2.4.1 |
poeTrapsControlGroupIndexThis variable uniquely identifies the group. INTEGER .1.3.6.1.4.1.24852.2.4.1.1 |
poeTrapsControlEnableEnable Traps from Agentrw Enumeration .1.3.6.1.4.1.24852.2.4.1.2 |
poeTraps OBJECT IDENTIFIER .1.3.6.1.4.1.24852.2.5 |
poePortHWFailTrapThis trap indicate UV0v failure /UV0v Spike failure /Device A2d failure. NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.1 |
poePortPeakOverCurrentTrapThis trap indicate peak over current failure. NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.2 |
poePortOverloadTrapThis trap indicate overload failure. If you put at least 400mA on the output, you will see if your traps work NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.3 |
poePortDiscoveryFailTrapThis trap indicate Discovery failure/ Discovery VA2 failure/Discovery RA2 failure/Sample Discovery A2d Failure. NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.4 |
poePortClassificationFailTrapThis trap indicate Class Violation failure/ Classification A2d failure. NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.5 |
poePortDisconnectTrapThis trap indicate port is disconnected. NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.6 |
poePortVoltageFailTrapThis trap indicate if PSM Port is no voltage failure. NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.7 |
poeSystemOverheatTrapThis trap indicate if PSM is overheat. NOTIFICATION-TYPE .1.3.6.1.4.1.24852.2.5.8 |