Home/Catalog/PERLE-MCR-MGT-MIB

PERLE-MCR-MGT-MIB

AI MIB Summary

The PERLE-MCR-MGT-MIB enables SNMP-based monitoring and configuration of Perle Managed Media Converters, specifically exposing interface status, link state transitions, port statistics, and device operational parameters. This module facilitates granular visibility into the physical layer connectivity and performance metrics of Perle's fiber-to-copper conversion hardware within enterprise network infrastructures.

The private MIB module for the Perle Managed Media Converters
Main OID:
mcrMGTMIB.1.3.6.1.4.1.1966.21.1.1
1856
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

1856 total
Object Name
perle
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966
productId
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.20
mediaConverter
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.20.1
mcrMGT
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.20.1.1
productMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21
mediaconverterMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1
mcrMGTMIBThe private MIB module for the Perle Managed Media Converters
MODULE-IDENTITY
.1.3.6.1.4.1.1966.21.1.1
mcrMGTMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.0
mcrMgtModuleInsertedTrap being sent indicates that a management module has been inserted int the chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.1
mcrMgtSystemBootTrap being sent indicates that the management module's system firmware is being booted up and has completed system initialization. In some case this alert will indicate a cold start like a user resetting the management module or warm start if the module automatically resets because of a detected crash.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.2
mcrMgtResetTrap being sent indicates that the management module has been manually reset via the reset button or one of the managers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.3
mcrMgtResetFactoryTrap being sent indicates that the management module has been manually reset to factory by holding the reset button for 3 or more seconds, or one of the managers. This means that any files downloaded to the management module will be erase and the management configuration file is reset back to the default configuration.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.4
mcrMgtEtheLinkUpTrap being sent indicates that the current link status of the Ethernet port on the management module is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.5
mcrMgtEtheLinkDownTrap being sent indicates that the current link status of the Ethernet port on the management module is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.6
mcrMgtConMonDSRSigChgTrap being sent indicates that monitor console DSR is configured and the status of one of these signal has changed on the console port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.7
mcrMgtAuthFailTrap being sent indicates that a user failed authentication via Telnet, SSH, WebManager, SNMP or the serial console.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.8
mcrMgtAuthSuccessTrap being sent indicates that a user failed authentication via Telnet, SSH, WebManager or the serial console.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.9
mcrMgtDateTimeChgTrap being sent indicates that the system date and/or time has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.10
mcrMgtSntpServFailTrap being sent indicates that SNTP is configured and the management module can not communicate with the configured SNTP server.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.11
mcrMgtSntpServRecTrap being sent indicates that the SNTP is configured and the management module has recovered communications with the configured SNTP server.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.12
mcrMgtSnmpTrapHostFailTrap being sent indicates that SNMP traps is and the management module can not communicate with the configured SNMP trap host. This trap will only be sent for SNMP trap hosts configured for 'Inform' type traps.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.13
mcrMgtSnmpTrapHostRecTrap being sent indicates that SNMP traps is and the management module has recovered communications with the configured SNMP trap host.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.14
mcrMgtEmailServFailTrap being sent indicates that an alert email server is configured and the management module can not communicate with the configured email server.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.15
mcrMgtEmailServRecTrap being sent indicates that an alert email server is configured and the management module has recovered communications with the configured email server.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.16
mcrMgtConfSavedFlashTrap being sent indicates that the configuration has been saved to flash on the management module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.17
mcrMgtIpAddrDynChgTrap being sent indicates that the system IP address has been dynamically changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.18
mcrMgtTftpUploadFailTrap being sent indicates that an attempt to transfer a file via TFTP, off the management module to a remote host has failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.19
mcrMgtTftpUploadSuccessTrap being sent indicates that an attempt to transfer a file via TFTP, off the management module to a remote host was successful.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.20
mcrMgtTftpDownloadFailTrap being sent indicates that an attempt to transfer a file via TFTP, from a remote host to the management module has failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.21
mcrMgtTftpDownloadSuccessTrap being sent indicates that an attempt to transfer a file via TFTP, from a remote host to the management module was successful.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.22
mcrMgtChassisMismatchTrap being sent indicates that the management module has been inserted into a chassis that does not match it's Backup media converter module configuration. Backup media module configurations will be reset to factory default.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.23
mcrChassisAddTrap being sent indicates that a new chassis as been added to the chain of chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.24
mcrChassisRemoveTrap being sent indicates that that a chassis has been removed from the chain of chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.25
mcrChassisResetTrap being sent indicates that the chassis back-plane has been manually reset by a user managing the unit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.26
mcrChassisTemperatureAlarmTrap being sent indicates that the chassis temperature has exceeded the configured high temperature threshold temperature.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.27
mcrChassisTemperatureRecoverTrap being sent indicates that the chassis temperature has recovered back to normal operating temperature.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.28
mcrChassisSlotPoweredOnTrap being sent indicates that the chassis slot has been powered off either manually or through the configured chassis slot power schedule.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.29
mcrChassisSlotPoweredOffTrap being sent indicates that the chassis slot has been powered on either manually or through the configured chassis slot power schedule.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.30
mcrChassisFailTrap being sent indicates that the management module has detected a failure condition in the chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.31
mcrChassisOkTrap being sent indicates that the chassis has recovered from a failure and is now operating normally.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.32
mcrPsmuInsertedTrap being sent indicates that a power supply has been inserted into the chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.33
mcrPsmuRemovedTrap being sent indicates that a power supply's has been removed from the chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.34
mcrPsmuPsuFailTrap being sent indicates that the power supply has failed it's self-test diagnostics.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.35
mcrPsmuPsuOkTrap being sent indicates that the power supply has passed it's self-test diagnostics.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.36
mcrPsmuPsuVoltageFailTrap being sent indicates that the voltage being supplied by the indicated power supply is insufficient.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.37
mcrPsmuPsuVoltageOkTrap being sent indicates that the voltage being supplied by the indicated power supply is now in the normal operating range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.38
mcrPsmuFanFailTrap being sent indicates that the fan has failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.39
mcrPsmuFanOkTrap being sent indicates that the fan currently operating normally.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.40
mcrMediaInsertedTrap being sent indicates that a media converter module has been inserted into the chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.42
mcrMediaRemovedTrap being sent indicates that a media converter module has been removed from the chassis.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.43
mcrMediaResetTrap being sent indicates that the media converter module has been manually reset by a user managing the unit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.44
mcrMediaLostCommunicationTrap being sent indicates that the management module can no longer communicate with the media converter module
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.45
mcrMediaRecovCommunicationTrap being sent indicates that the management module recovered communication with a media converter module
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.46
mcrMediaFailTrap being sent indicates that the media converter module has failed its self-test diagnostics
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.47
mcrMediaOkTrap being sent indicates that the media converter module has passed its self-test diagnostics
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.48
mcrMediaLinkUpTrap being sent indicates that the current link status of the Fiber or Copper port on the media converter module is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.49
mcrMediaLinkDownTrap being sent indicates that the current link status of the Fiber or Copper port on the media converter module is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.50
mcrMediaConfUpdateFailTrap being sent indicates that the configuration update on the media converter module has failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.51
mcrMediaConfUpdateSuccessTrap being sent indicates that the configuration update on the media converter module was successful. The media converter module configuration can be updated manually or automatically.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.52
mcrMediaConfMismatchTrap being sent indicates that a chassis slot is configured with Backup/Restore and the media converter module type configured for the slot does not match the media converter module type inserted into the slot.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.53
mcrMediaConfMismatchResolvTrap being sent indicates that a user has taken action to resolved media converter module configuration mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.54
mcrMediaFirmwareUpdateFailTrap being sent indicates that an attempt to update a media converter module's firmware has Failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.55
mcrMediaFirmwareUpdateSuccessTrap being sent indicates that an attempt to update a media converter module's firmware was successful.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.56
mcrSfpInsertedTrap being sent indicates that a SFP module has been inserted into a media converter module
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.57
mcrSfpRemovedTrap being sent indicates that a SFP module has been removed from a media converter module
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.58
mcrSfpHighTempWarnTrap being sent indicates that a SFP module's temperature has exceeded the high temperature warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.59
mcrSfpHighTempWarnRecovTrap being sent indicates that a SFP module's temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.60
mcrSfpHighTempAlarmTrap being sent indicates that a SFP module's temperature has exceeded the high temperature alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.61
mcrSfpHighTempAlarmRecovTrap being sent indicates that a SFP module's temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.62
mcrSfpLowTempWarnTrap being sent indicates that a SFP module's temperature has gone below the low temperature warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.63
mcrSfpLowTempWarnRecovTrap being sent indicates that a SFP module's temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.64
mcrSfpLowTempAlarmTrap being sent indicates that a SFP module's temperature has gone below the low temperature alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.65
mcrSfpLowTempAlarmRecovTrap being sent indicates that a SFP module's temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.66
mcrSfpHighVoltWarnTrap being sent indicates that a SFP module's voltage has exceeded the high voltage warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.67
mcrSfpHighVoltWarnRecovTrap being sent indicates that a SFP module's voltage has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.68
mcrSfpHighVoltAlarmTrap being sent indicates that a SFP module's voltage has exceeded the high voltage alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.69
mcrSfpHighVoltAlarmRecovTrap being sent indicates that a SFP module's voltage has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.70
mcrSfpLowVoltWarnTrap being sent indicates that a SFP module's voltage has gone below the low voltage warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.71
mcrSfpLowVoltWarnRecovTrap being sent indicates that a SFP module's voltage has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.72
mcrSfpLowVoltAlarmTrap being sent indicates that a SFP module's voltage has gone below the low voltage alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.73
mcrSfpLowVoltAlarmRecovTrap being sent indicates that a SFP module's voltage has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.74
mcrSfpHighTxBiasWarnTrap being sent indicates that a SFP module's TX Bias current has exceeded the high TX Bias current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.75
mcrSfpHighTxBiasWarnRecovTrap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.76
mcrSfpHighTxBiasAlarmTrap being sent indicates that a SFP module's TX Bias current has exceeded the high TX Bias current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.77
mcrSfpHighTxBiasAlarmRecovTrap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.78
mcrSfpLowTxBiasWarnTrap being sent indicates that a SFP module's TX Bias current has gone below the low Tx Bias current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.79
mcrSfpLowTxBiasWarnRecovTrap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.80
mcrSfpLowTxBiasAlarmTrap being sent indicates that a SFP module's TX Bias current has gone below the low Tx Bias current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.81
mcrSfpLowTxBiasAlarmRecovTrap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.82
mcrSfpHighTxPowerWarnTrap being sent indicates that a SFP module's TX power has exceeded the high TX power warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.83
mcrSfpHighTxPowerWarnRecovTrap being sent indicates that a SFP module's TX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.84
mcrSfpHighTxPowerAlarmTrap being sent indicates that a SFP module's TX power has exceeded the high TX power alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.85
mcrSfpHighTxPowerAlarmRecovTrap being sent indicates that a SFP module's TX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.86
mcrSfpLowTxPowerWarnTrap being sent indicates that a SFP module's TX power has gone below the low TX power warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.87
mcrSfpLowTxPowerWarnRecovTrap being sent indicates that a SFP module's TX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.88
mcrSfpLowTxPowerAlarmTrap being sent indicates that a SFP module's TX power has gone below the low TX power alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.89
mcrSfpLowTxPowerAlarmRecovTrap being sent indicates that a SFP module's TX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.90
mcrSfpHighRxPowerWarnTrap being sent indicates that a SFP module's RX power has exceeded the high RX power warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.91
mcrSfpHighRxPowerWarnRecovTrap being sent indicates that a SFP module's RX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.92
mcrSfpHighRxPowerAlarmTrap being sent indicates that a SFP module's RX power has exceeded the high RX power alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.93
mcrSfpHighRxPowerAlarmRecovTrap being sent indicates that a SFP module's RX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.94
mcrSfpLowRxPowerWarnTrap being sent indicates that a SFP module's RX power has gone below the low RX power warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.95
mcrSfpLowRxPowerWarnRecovTrap being sent indicates that a SFP module's RX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.96
mcrSfpLowRxPowerAlarmTrap being sent indicates that a SFP module's RX power has gone below the low RX power alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.97
mcrSfpLowRxPowerAlarmRecovTrap being sent indicates that a SFP module's RX power has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.98
mcrChassisCommTempSensorFailTrap being sent indicates that communication with the chassis temperature sensor has failed. The current chassis temperature reading will be unknown
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.99
mcrChassisCommTempSensorRecovTrap being sent indicates that communication with the chassis temperature sensor has recovered.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.100
mcrMediaDetectFailTrap being sent indicates that the indicated media card is being powered down due to the detection of a hardware failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.101
mcrMediaBadImageTrap being sent indicates that the CRC of the media converter module firmware is incorrect. This can be caused if there is no image on the module or the image is corrupt.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.102
mcrSfpLostCommTrap being sent indicates that the media converter module's microcode can no longer communicate with the SFP module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.103
mcrSfpRecovCommTrap being sent indicates that the media converter module's microcode had previously lost communication with, but has now regained communication with the SFP module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.104
mcrModuleNotSupportedTrap being sent indicates that the media converter module is not fully supported by the management module. Update the management module firmware to rectify this issue.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.105
mcrModuleFirmwareUpdateTrap being sent indicates that the media converter module firmware is being updated.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.106
mcrSfpPortShutdownTrap being sent indicates that the Sfp/Xfp port has been shutdown due to high temperature.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.107
mcrSfpPortShutdownRecovTrap being sent indicates that the Sfp/Xfp port shutdown has recovered.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.108
mcrXfpHighApdBiasWarnTrap being sent indicates that an XFP module's APD Bias Current has exceeded the high APD Bias warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.109
mcrXfpHighApdBiasWarnRecovTrap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.110
mcrXfpHighApdBiasAlarmTrap being sent indicates that an XFP module's APD Bias Current has exceeded the high APD Bias alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.111
mcrXfpHighApdBiasAlarmRecovTrap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.112
mcrXfpLowApdBiasWarnTrap being sent indicates that an XFP module's APD Bias Current has gone below the low APD Bias warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.113
mcrXfpLowApdBiasWarnRecovTrap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.114
mcrXfpLowApdBiasAlarmTrap being sent indicates that an XFP module's APD Bias Current has gone below the low APD Bias alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.115
mcrXfpLowApdBiasAlarmRecovTrap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.116
mcrXfpHighTecCurrentWarnTrap being sent indicates that an XFP module's TEC Current has exceeded the high TEC Current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.117
mcrXfpHighTecCurrentWarnRecovTrap being sent indicates that an XFP module's TEC Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.118
mcrXfpHighTecCurrentAlarmTrap being sent indicates that an XFP module's TEC Current has exceeded the high TEC Current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.119
mcrXfpHighTecCurrentAlarmRecovTrap being sent indicates that an XFP module's TEC Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.120
mcrXfpLowTecCurrentWarnTrap being sent indicates that an XFP module's TEC Current has gone below the low TEC Current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.121
mcrXfpLowTecCurrentWarnRecovTrap being sent indicates that an XFP module's TEC Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.122
mcrXfpLowTecCurrentAlarmTrap being sent indicates that an XFP module's TEC Current has gone below the low TEC Current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.123
mcrXfpLowTecCurrentAlarmRecovTrap being sent indicates that an XFP module's TEC Current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.124
mcrXfpHighLaserTempWarnTrap being sent indicates that an XFP module's Laser Temperature has exceeded the high Laser Temperature warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.125
mcrXfpHighLaserTempWarnRecovTrap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.126
mcrXfpHighLaserTempAlarmTrap being sent indicates that an XFP module's Laser Temperature has exceeded the high Laser Temperature alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.127
mcrXfpHighLaserTempAlarmRecovTrap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.128
mcrXfpLowLaserTempWarnTrap being sent indicates that an XFP module's Laser Temperature has gone below the low Laser Temperature warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.129
mcrXfpLowLaserTempWarnRecovTrap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.130
mcrXfpLowLaserTempAlarmTrap being sent indicates that an XFP module's Laser Temperature has gone below the low Laser Temperature alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.131
mcrXfpLowLaserTempAlarmRecovTrap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.132
mcrXfpHighLaserWavelengthWarnTrap being sent indicates that an XFP module's Laser Wavelength has exceeded the high Laser Wavelength warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.133
mcrXfpHighLaserWavelengthWarnRecovTrap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.134
mcrXfpHighLaserWavelengthAlarmTrap being sent indicates that an XFP module's Laser Wavelength has exceeded the high Laser Wavelength alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.135
mcrXfpHighLaserWavelengthAlarmRecovTrap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.136
mcrXfpLowLaserWavelengthWarnTrap being sent indicates that an XFP module's Laser Wavelength has gone below the low Laser Wavelength warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.137
mcrXfpLowLaserWavelengthWarnRecovTrap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.138
mcrXfpLowLaserWavelengthAlarmTrap being sent indicates that an XFP module's Laser Wavelength has gone below the low Laser Wavelength alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.139
mcrXfpLowLaserWavelengthAlarmRecovTrap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.140
mcrXfpHigh5VoltWarnTrap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.141
mcrXfpHigh5VoltWarnRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.142
mcrXfpHigh5VoltAlarmTrap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.143
mcrXfpHigh5VoltAlarmRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.144
mcrXfpLow5VoltWarnTrap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.145
mcrXfpLow5VoltWarnRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.146
mcrXfpLow5VoltAlarmTrap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.147
mcrXfpLow5VoltAlarmRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.148
mcrXfpHigh33VoltWarnTrap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.149
mcrXfpHigh33VoltWarnRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.150
mcrXfpHigh33VoltAlarmTrap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.151
mcrXfpHigh33VoltAlarmRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.152
mcrXfpLow33VoltWarnTrap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.153
mcrXfpLow33VoltWarnRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.154
mcrXfpLow33VoltAlarmTrap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.155
mcrXfpLow33VoltAlarmRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.156
mcrXfpHigh18VoltWarnTrap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.157
mcrXfpHigh18VoltWarnRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.158
mcrXfpHigh18VoltAlarmTrap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.159
mcrXfpHigh18VoltAlarmRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.160
mcrXfpLow18VoltWarnTrap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.161
mcrXfpLow18VoltWarnRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.162
mcrXfpLow18VoltAlarmTrap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.163
mcrXfpLow18VoltAlarmRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.164
mcrXfpHighM52VoltWarnTrap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.165
mcrXfpHighM52VoltWarnRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.166
mcrXfpHighM52VoltAlarmTrap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.167
mcrXfpHighM52VoltAlarmRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.168
mcrXfpLowM52VoltWarnTrap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.169
mcrXfpLowM52VoltWarnRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.170
mcrXfpLowM52VoltAlarmTrap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.171
mcrXfpLowM52VoltAlarmRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.172
mcrXfpHigh5VCurrentWarnTrap being sent indicates that an XFP module's +5v supply current has exceeded the high +5v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.173
mcrXfpHigh5VCurrentWarnRecovTrap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.174
mcrXfpHigh5VCurrentAlarmTrap being sent indicates that an XFP module's +5v supply current has exceeded the high +5v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.175
mcrXfpHigh5VCurrentAlarmRecovTrap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.176
mcrXfpLow5VCurrentWarnTrap being sent indicates that an XFP module's +5v supply current has gone below the low +5v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.177
mcrXfpLow5VCurrentWarnRecovTrap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.178
mcrXfpLow5VCurrentAlarmTrap being sent indicates that an XFP module's +5v supply current has gone below the low +5v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.179
mcrXfpLow5VCurrentAlarmRecovTrap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.180
mcrXfpHigh33VCurrentWarnTrap being sent indicates that an XFP module's +3.3v supply current has exceeded the high +3.3v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.181
mcrXfpHigh33VCurrentWarnRecovTrap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.182
mcrXfpHigh33VCurrentAlarmTrap being sent indicates that an XFP module's +3.3v supply current has exceeded the high +3.3v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.183
mcrXfpHigh33VCurrentAlarmRecovTrap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.184
mcrXfpLow33VCurrentWarnTrap being sent indicates that an XFP module's +3.3v supply current has gone below the low +3.3v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.185
mcrXfpLow33VCurrentWarnRecovTrap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.186
mcrXfpLow33VCurrentAlarmTrap being sent indicates that an XFP module's +3.3v supply current has gone below the low +3.3v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.187
mcrXfpLow33VCurrentAlarmRecovTrap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.188
mcrXfpHigh18VCurrentWarnTrap being sent indicates that an XFP module's +1.8v supply current has exceeded the high +1.8v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.189
mcrXfpHigh18VCurrentWarnRecovTrap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.190
mcrXfpHigh18VCurrentAlarmTrap being sent indicates that an XFP module's +1.8v supply current has exceeded the high +1.8v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.191
mcrXfpHigh18VCurrentAlarmRecovTrap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.192
mcrXfpLow18VCurrentWarnTrap being sent indicates that an XFP module's +1.8v supply current has gone below the low +1.8v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.193
mcrXfpLow18VCurrentWarnRecovTrap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.194
mcrXfpLow18VCurrentAlarmTrap being sent indicates that an XFP module's +1.8v supply current has gone below the low +1.8v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.195
mcrXfpLow18VCurrentAlarmRecovTrap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.196
mcrXfpHighM52VCurrentWarnTrap being sent indicates that an XFP module's -5.2v supply current has exceeded the high -5.2v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.197
mcrXfpHighM52VCurrentWarnRecovTrap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.198
mcrXfpHighM52VCurrentAlarmTrap being sent indicates that an XFP module's -5.2v supply current has exceeded the high -5.2v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.199
mcrXfpHighM52VCurrentAlarmRecovTrap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.200
mcrXfpLowM52VCurrentWarnTrap being sent indicates that an XFP module's -5.2v supply current has gone below the low -5.2v supply current warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.201
mcrXfpLowM52VCurrentWarnRecovTrap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.202
mcrXfpLowM52VCurrentAlarmTrap being sent indicates that an XFP module's -5.2v supply current has gone below the low -5.2v supply current alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.203
mcrXfpLowM52VCurrentAlarmRecovTrap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.204
mcrXfpHighVCC5WarnTrap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.205
mcrXfpHighVCC5WarnRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.206
mcrXfpHighVCC5AlarmTrap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.207
mcrXfpHighVCC5AlarmRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.208
mcrXfpLowVCC5WarnTrap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.209
mcrXfpLowVCC5WarnRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.210
mcrXfpLowVCC5AlarmTrap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.211
mcrXfpLowVCC5AlarmRecovTrap being sent indicates that an XFP module's +5v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.212
mcrXfpHighVCC3WarnTrap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.213
mcrXfpHighVCC3WarnRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.214
mcrXfpHighVCC3AlarmTrap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.215
mcrXfpHighVCC3AlarmRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.216
mcrXfpLowVCC3WarnTrap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.217
mcrXfpLowVCC3WarnRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.218
mcrXfpLowVCC3AlarmTrap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.219
mcrXfpLowVCC3AlarmRecovTrap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.220
mcrXfpHighVCC2WarnTrap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.221
mcrXfpHighVCC2WarnRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.222
mcrXfpHighVCC2AlarmTrap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.223
mcrXfpHighVCC2AlarmRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.224
mcrXfpLowVCC2WarnTrap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.225
mcrXfpLowVCC2WarnRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.226
mcrXfpLowVCC2AlarmTrap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.227
mcrXfpLowVCC2AlarmRecovTrap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.228
mcrXfpHighVEE5WarnTrap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.229
mcrXfpHighVEE5WarnRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.230
mcrXfpHighVEE5AlarmTrap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.231
mcrXfpHighVEE5AlarmRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.232
mcrXfpLowVEE5WarnTrap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply warning threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.233
mcrXfpLowVEE5WarnRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.234
mcrXfpLowVEE5AlarmTrap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply alarm threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.235
mcrXfpLowVEE5AlarmRecovTrap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.236
mcrSfpSpeedMismatchTrap being sent indicates that there is a speed mismatch between the two SFP modules installed in the media converter.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.237
mcrSfpSpeedMismatchRecovTrap being sent indicates that the speed mismatch between the two SFP modules has recovered.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.238
mcrXfpPowerExceededTrap being sent indicates that an XFP module's power requirements has exceeded card capacity.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.239
mcrXfpPowerExceededRecovTrap being sent indicates that the XFP excessive power alarm has recovered.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.240
mcrLinkTestErrorTrap being sent indicates that the link test running on the media converter has detected errors.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.241
mcrAlarmRelayEngagedTrap being sent indicates that the chassis alarm relay has engaged
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.242
mcrAlarmRelayDisengagedTrap being sent indicates that the chassis alarm relay has disengaged
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.243
mcrBandwidthLevelUpstreamLowTrap being sent indicates the media port is in a low upstream bandwidth condition. This happens when the bandwidth is below the configured threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.244
mcrBandwidthLevelUpstreamRecovTrap being sent indicates the media port has recovered from a low upstream bandwidth condition.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.245
mcrBandwidthLevelDownstreamLowTrap being sent indicates the media port is in a low downstream bandwidth condition. This happens when the bandwidth is below the configured threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.246
mcrBandwidthLevelDownstreamRecovTrap being sent indicates the media port has recovered from a low downstream bandwidth condition.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.247
mcrMediaRemoteResetTrap being sent indicates that the media converter module's peer has been manually reset by a user managing the unit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1966.21.1.1.0.248
mcrMGTMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1
mcrChassisGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1
mcrChassisTableTable of chassis diagnostic type information.
SEQUENCE OF McrChassisEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.1
mcrChassisEntryEntries of the table, each relating to a separate chassis.
McrChassisEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1
mcrChassisIndexThis object identifies the chassis number.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.1
chassisModelNameThis object identifies the name of the chassis model. For the 2-slot chassis, this is the product model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.2
chassisModelDescThis object identifies a static description of the chassis.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.3
chassisSerialNumberThis object identifies the chassis serial number. For the 2-slot chassis, this is writeable (and user-defined). For other chassis, this is read-only (and reflects the chassis' actual serial number).rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.4
chassisBootloaderVersionThis object identifies the chassis bootloader version. (Not applicable to 2-slot chassis.)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.5
chassisFirmwareVersionThis object identifies the chassis firmware version. (Not applicable to 2-slot chassis.)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.6
chassisOutStandWarnAlarmsThis object identifies the number of outstanding warnings and alarms for this chassis. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarms. (Not applicable to 2-slot chassis.)ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.7
chassisDiagStatusThis object identifies the chassis self-test diagnostics result. It will return zero if it passed and non-zero error code if it failed. The following are possible non-zero error codes: 1 - Firmware download required 2 - Temperature sensor not functional (Not applicable to 2-slot chassis.)ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.8
chassisTemperatureThis object identifies the current temperature of the chassis. The temperature returned will be either Celsius or Fahrenheit based on your current regional display settings. If the temperature returned is -1 then a problem with the temperature sensor has occurred and the current temperature is unknown. (Not applicable to 2-slot chassis.)ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.9
chassisCfgHighTempThresholdThis object identifies the chassis temperature high threshold. If the chassis temperature exceeds this threshold then an alert will be generated. The value read/written will be either Celsius or Fahrenheit based on your current regional display settings. The valid range for this threshold is 0 to 70 degrees Celsius or 32 to 158 degrees Fahrenheit. (Not applicable to 2-slot chassis.)rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.10
chassisResetThis object allows the resetting of the chassis (all modules). Reading this object always returns 0.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.11
chassisCfgMgmtSlotFor the 2-slot chassis, this is the configured slot index of the management module. This value only needs to be changed if the management module is physically installed in slot 2, rather than slot 1. The management module should be restarted after changing this value.rw
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.1.1.12
mcrPsmuTableTable of PSMU (Power Supply Monitoring Unit) diagnostic type information. (Not applicable to 2-slot chassis.)
SEQUENCE OF McrPsmuEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.2
mcrPsmuEntryEntries of the table, each relating to a separate PSMU.
McrPsmuEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1
mcrPsmuIndexThis object identifies the PSMU bay as either A or B.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.2
mcrPsmuModelNameThis object identifies the PSMU model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.3
mcrPsmuModelDescThis object identifies a static description of the power supply model present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.4
mcrPsmuPsuSerialNumberThis object identifies the PSU serial number.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.5
mcrPsmuBootloaderVersionThis object identifies the PSMU bootloader version.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.6
mcrPsmuFirmwareVersionThis object identifies the PSMU firmware version.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.7
mcrPsmuOutStandWarnAlarmsThis object identifies the number of outstanding warnings and alarms for this chassis. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarmsro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.8
mcrPsmuPsuStatusThis object identifies if the PSMU power supply unit (PSU) status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.9
mcrPsmuPsuVoltageThis object identifies the current PSU voltage being supplied.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.10
mcrPsmuPsuPowerUsageThis object identifies power currently being supplied to the chassis, in milliwatts. A value of 0 indicate that the power supply is not in usero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.11
mcrPsmuFanStatusThis object identifies the fan status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.12
mcrPsmuFanSpeedThis object identifies the speed of the fan in RPM.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.2.1.13
mcrChassisSlotTableTable of chassis slot configuration, status and diagnostic type information.
SEQUENCE OF McrChassisSlotEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.3
mcrChassisSlotEntryEntries of the table, each relating to a separate slot in a chassis.
McrChassisSlotEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1
mcrChassisSlotIndexThis object identifies the chassis slot number.ro
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.2
mcrUserDefinedModuleNameThis object identifies the user defined name of the module inserted in the slot. The default name is the model name of the media converter modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.3
mcrModuleModelNameThis object identifies the model name of the module inserted in the slot.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.4
mcrUnManagedModuleSlotNameThis object identifies the user defined name for an unmanaged module inserted in the slot. Unmanaged modules include all perle C-1000, C-100, C-1110 and c-110 type modules.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.5
mcrModuleSerialNumberThis object identifies the serial number of the module inserted in the slot.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.6
mcrModuleBootloaderVersionThis object identifies the bootloader version of the module inserted in the slot.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.7
mcrModuleFirmwareVersionThis object identifies the firmware version of the module inserted in the slot.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.8
mcrModuleoOutStandWarnAlarmsThis object identifies the number of outstanding warnings and alarms for this module. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarmsro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.9
mcrModuleDiagStatusThis object identifies the module's self-test diagnostics result. It will return zero if it passed and non-zero error code if the module has failed.The following are possible non-zero error codes: 1 - Media converter module's PHY is not functional. 2 - Firmware download requiredro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.10
mcrModuleTypeInsertedThis object identifies the module type inserted for this chassis slot.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.11
mcrMediaConfigBackupRestoreThis object is applicable to media converter modules only. It identifies whether the media configuration will be automatically backed up to or restored from the management card's non-volatile memoryrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.12
mcrMediaBackedupModuleTypeThis object identifies the media converter module type of the configuration that was backed up for the slot on the management card's non-volatile memory when the mcrMediaConfigBackupRestore object was enabled.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.13
mcrChassisPwrUpSlotPwrStateThis object identifies the default power state of the slot when the chassis is initially powered up. The current power state of the slot can be manually changed by writing to mcrCurrentPowerState object or dynamically changed via slot power schedule configuration. (Not applicable to 2-slot chassis.)rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.14
mcrCurrentPowerStateWriting this object allows the current power state of the slot to be turned on or off. This object is not writable for management modules or the 2-slot chassis. Reading this object will return the current slot power state.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.15
mcrPowerScheduleEnableThis object is not applicable to management modules. It identifies if power schedule is enabled for the slot. (Not applicable to 2-slot chassis.)rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.16
mcrModuleResetThis object allows you to reset the module inserted in the slot.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.17
mcrModuleResetToFactoryThis object allows you to reset to factory the module inserted in the slot.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.18
mcrModuleModelDescThis object identifies a static description of the media converter module present in the slot.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.19
mcrModuleTypes
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4
cm1000Fixed
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1
cm1000FixedTableTable of CM-1000 type media converter module's status type information.
SEQUENCE OF Cm1000FixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1
cm1000FixedEntryEntries of the table, each relating to a separate CM-1000 type media converter module.
Cm1000FixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1
cm1000SlotIndexThe Slot number the CM-1000 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.2
cm1000ModelnameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.3
cm1000ModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.4
cm1000HwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.5
cm1000HwSw1FiberAutoNegMedia converter module's current switch setting for fiber Auto-Negotiation.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.6
cm1000HwSw2LinkModeMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.7
cm1000HwSw3FiberFaultAlertMedia converter module's current switch setting for Fiber Fault Alert.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.8
cm1000HwSw4DuplexMedia converter module's current switch setting for copper duplex.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.9
cm1000HwSw5PauseMedia converter module's current switch setting for copper pause (flow control).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.10
cm1000HwSw6LoopbackMedia converter module's current switch setting for fiber loopback mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.11
cm1000FiberLinkStatusMedia converter module's current fiber link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.12
cm1000FiberConnTypeMedia converter module's fiber port connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.13
cm1000FiberAutoNegStateMedia converter module's current fiber auto-negotiation state.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.14
cm1000FiberSpeedMedia converter module's fiber port speed in megabits per second.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.15
cm1000FiberDuplexIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.16
cm1000FiberPauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.17
cm1000FiberLPRFStatusMedia converter module's fiber Link Partner Remote Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.18
cm1000FiberReceiveStatusThis object identifies the status of whether light is being received on the fiber portrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.19
cm1000FiberLoopBackMedia converter module's current fiber loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.20
cm1000CopperLinkStatusMedia converter module's current copper link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.21
cm1000CopperConnTypeMedia converter module's copper connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.22
cm1000CopperAutoNegStateMedia converter module's current copper auto-negotiation state.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.23
cm1000CopperSpeedMedia converter module's copper port speed in megabits per second.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.24
cm1000CopperDuplexIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.25
cm1000CopperCrossOverIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.26
cm1000CopperPauseEnhIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.27
cm1000CopperLPRFStatusMedia converter module's copper Link Partner Remote Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.28
cm1000ConfigTableTable of CM-1000 type media converter module's configuration type information.
SEQUENCE OF Cm1000ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2
cm1000ConfigEntryEntries of the table, each relating to a separate CM-1000 type media converter module.
Cm1000ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1
cm1000ConfigSlotIndexThe Slot number the CM-1000 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.2
cm1000ConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.3
cm1000ConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.4
cm1000ConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.5
cm1000ConfigFiberFaultAlertThis object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.6
cm1000ConfigJumboPacketsThis object identifies the Jumbo Packet setting for the media converter module present in the chassis.rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.7
cm1000ConfigFiberPortNameThis object identifies a user definable name for the fiber port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.8
cm1000ConfigFiberPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.9
cm1000ConfigFiberAutoNegThis object identifies the wither fiber auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.10
cm1000ConfigCopperPortNameThis object identifies a user definable name for the copper port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.11
cm1000ConfigCopperPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.12
cm1000ConfigCopperDuplexThis object identifies the duplex settings for the copper port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.13
cm1000ConfigCopperPauseEnhThis object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.14
cm1000ConfigCopperLowPowerThis object identifies the copper low power setting for the media converter module present in the chassis.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.15
cm1000LedTableTable of CM-1000 type media converter module's LED status information.
SEQUENCE OF Cm1000LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3
cm1000LedEntryEntries of the table, each relating to a separate CM-1000 type media converter module.
Cm1000LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1
cm1000LedSlotIndexThe Slot number the CM-1000 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.2
cm1000LedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.3
cm1000LedLKFThis object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.4
cm1000LedLKCThis object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.5
cm100Fixed
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2
cm100FixedTableTable of CM-100 type media converter module's configuration and status type information.
SEQUENCE OF Cm100FixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1
cm100FixedEntryEntries of the table, each relating to a separate CM-1000 type media converter module.
Cm100FixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1
cm100SlotIndexThe Slot number the CM-100 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.2
cm100ModelNameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.3
cm100ModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.4
cm100HwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.5
cm100HwJmp6AutoMDIThis object identifies the media converter module's hardware Auto MDIX jumper settings.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.6
cm100HwSw1AutoNegotiationMedia converter module's current switch setting for fiber Auto-Negotiation.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.7
cm100HwSw2LinkModeMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.8
cm100HwSw3FarEndFaultMedia converter module's current switch setting for Far End Fault.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.9
cm100HwSw5PauseMedia converter module's current switch setting for copper pause (flow control).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.10
cm100HwSw6LoopbackMedia converter module's current switch setting for fiber loopback mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.11
cm100FiberLinkStatusMedia converter module's current fiber link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.12
cm100FiberConnTypeMedia converter module's fiber port connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.13
cm100FiberSpeedMedia converter module's fiber port speed in megabits per second.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.14
cm100FiberFarEndFaultMedia converter module's current fiber Far End Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.15
cm100FiberReceiveStatusThis object identifies the status of whether light is being received on the fiber portrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.16
cm100FiberLoopBackThis object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.17
cm100CopperLinkStatusMedia converter module's current copper link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.18
cm100CopperConnTypeMedia converter module's copper connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.19
cm100CopperAutoNegStateMedia converter module's current copper auto-negotiation state.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.20
cm100CopperSpeedThis object identifies the copper port speed in megabits per second.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.21
cm100CopperDuplexIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.22
cm100CopperCrossOverIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.23
cm100CopperPauseIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause (flow control) setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.24
cm100CopperLPRFStatusMedia converter module's copper Link Partner Remote Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.25
cm100ConfigTableTable of CM-100 type media converter module's configuration and status type information.
SEQUENCE OF Cm100ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2
cm100ConfigEntryEntries of the table, each relating to a separate CM-1000 type media converter module.
Cm100ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1
cm100ConfigSlotIndexThe Slot number the CM-1000 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.2
cm100ConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.3
cm100ConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.4
cm100ConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.5
cm100ConfigFiberFarEndFaultThis object identifies the fiber Far End Fault setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.6
cm100ConfigFiberPortNameThis object identifies a user definable name for the fiber port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.7
cm100ConfigFiberPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.8
cm100ConfigCopperPortNameThis object identifies a user definable name for the copper port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.9
cm100ConfigCopperPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.10
cm100ConfigCopperAutoNegotiationThis object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.11
cm100ConfigCopperCrossOverThis object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set torw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.12
cm100ConfigCopperPauseThis object identifies the copper's port pause (flow control) settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.13
cm100LedTableTable of CM-100 type media converter module's LED status information.
SEQUENCE OF Cm100LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3
cm100LedEntryEntries of the table, each relating to a separate CM-100 type media converter module.
Cm100LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1
cm100LedSlotIndexThe Slot number the CM-100 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.2
cm100LedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.3
cm100LedLKFThis object identifies the status of the link fiber (LKF) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.4
cm100LedLKCThis object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.5
cm1110RateConv
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3
cm1110RateConvTableTable of CM-1110 type media converter module's configuration and status type information.
SEQUENCE OF Cm1110RateConvEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1
cm1110RateConvEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
Cm1110RateConvEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1
cm1110SlotIndexThe Slot number the CM-1110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.2
cm1110ModelNameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.3
cm1110ModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.4
cm1110HwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.5
cm1110HwJmp6AutoMDIXThis object identifies the media converter module's hardware Auto MDIX jumper settings.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.6
cm1110HwSw1TpAutoNegotiationMedia converter module's current switch setting for copper Auto-Negotiation.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.7
cm1110HwSw2LinkModeMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.8
cm1110HwSw3FiberFaultAlertMedia converter module's current switch setting for Fiber Fault Alert.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.9
cm1110HwSw4TpDuplexMedia converter module's current switch setting for copper duplex.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.10
cm1110HwSw5TpSpeedMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.11
cm1110HwSw6FiberAutoNegotiationMedia converter module's current switch setting for fiber Auto-Ngotiation. This object is not applicable if there is a 100 Mbps SFP modules inserted.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.12
cm1110HwSw6FiberSfp100DuplexMedia converter module's current switch setting for fiber duplex if a 100 Mbps SFP module is inserted. Otherwise this object is not applicable.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.13
cm1110HwSw7LoopbackMedia converter module's current switch setting for fiber loopback mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.14
cm1110FiberLinkStatusMedia converter module's current fiber link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.15
cm1110FiberConnTypeMedia converter module's fiber port connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.16
cm1110FiberAutoNegStateMedia converter module's current fiber auto-negotiation state. This object is not applicable if the fiber connector type is a 100 Mbps SFP module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.17
cm1110FiberSpeedIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.18
cm1110FiberDuplexThis object identifies the current fiber port duplex state.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.19
cm1110FiberPauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.20
cm1110FiberLPRFStatusMedia converter module's fiber Link Partner Remote Fault status. This object is not applicable if there is a 100 Mbps SFP module inserted.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.21
cm1110FiberSfp100FarEndFaultMedia converter module's current fiber Far End Fault status if a 100 Mbps SFP module is inserted. Otherwise this object is not applicable.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.22
cm1110FiberReceiveStatusThis object identifies the status of whether light is being received on the fiber portrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.23
cm1110FiberLoopBackThis object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.24
cm1110CopperLinkStatusMedia converter module's current copper link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.25
cm1110CopperConnTypeMedia converter module's copper connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.26
cm1110CopperAutoNegStateMedia converter module's current copper auto-negotiation state.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.27
cm1110CopperSpeedIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.28
cm1110CopperDuplexIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.29
cm1110CopperCrossOverIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.30
cm1110CopperPauseEnhIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.31
cm1110CopperLPRFStatusMedia converter module's copper Link Partner Remote Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.32
cm1110CopperAutoSpeedDownshiftThis object identifies the status of the copper auto speed downshift feature. noDownshift indicates that an automatic downshift of the copper speed has not occurred.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.33
cm1110ConfigTableTable of CM-1110 type media converter module's configuration type information.
SEQUENCE OF Cm1110ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2
cm1110ConfigEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
Cm1110ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1
cm1110ConfigSlotIndexThe Slot number the CM-1110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.2
cm1110ConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.3
cm1110ConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.4
cm1110ConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.5
cm1110ConfigFiberFaultAlertThis object identifies the Fiber Fault Alert setting for the media module. For 100 Mbps SFP modules, this setting is always effectively enabled if Link Mode is set to smartLinkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.6
cm1110ConfigMaxPacketsSizeThis object identifies the media converter module's maximum packet size setting This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.7
cm1110ConfigFiberPortNameThis object identifies a user definable name for the fiber port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.8
cm1110ConfigFiberPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.9
cm1110ConfigFiberAutoNegotiationThis object identifies whether fiber auto-negotiation is enabled. This object does not apply if the fiber connector type is a 100 Mbps SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.10
cm1110ConfigFiberSfp100duplexIf the fiber connector type is SFP and it is a 100 Mbps fiber module then this object identifies the duplex setting for the 100 Mbps fiber port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.11
cm1110ConfigCopperPortNameThis object identifies a user definable name for the copper port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.12
cm1110ConfigCopperPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.13
cm1110ConfigCopperAutoNegotiationThis object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.14
cm1110ConfigCopperAutoNegAdv10HDXThis object controls whether or the copper port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.15
cm1110ConfigCopperAutoNegAdv10FDXThis object controls whether or the copper port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.16
cm1110ConfigCopperAutoNegAdv100HDXThis object controls whether or the copper port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.17
cm1110ConfigCopperAutoNegAdv100FDXThis object controls whether or the copper port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.18
cm1110ConfigCopperAutoNegAdv1000FDXThis object controls whether or the copper port advertises willingness to connect at 1000Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.19
cm1110ConfigCopperSpeedIf copper auto-negotiation is disabled then this object identifies the configured cooper speed. 1000 Mbps speed can only be auto negotiated. If copper auto-negotiation is enabled then this object is ignored. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.20
cm1110ConfigCopperDuplexIf copper auto-negotiation is disabled then this object identifies the duplex setting for 10 & 100 Mbps for the copper port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.21
cm1110ConfigCopperCrossOverThis object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set torw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.22
cm1110ConfigCopperPauseEnhThis object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.23
cm1110ConfigCopperAutoSpeedDownshiftThis object identifies the number of times the PHY attempts to establish a Gigabit link before the PHY downshift to the next highest speed. A value of 0 indicates the auto downshift is disabledrw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.24
cm1110ConfigCopper10BaseTDistanceWhen using cable exceeding 100 meters in 10BASE-T mode this feature should be set to extended(1).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.25
cm1110ConfigUnidirectionalEthernetRestrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.26
cm1110ConfigPriorityToEgressQueueMap0Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.27
cm1110ConfigPriorityToEgressQueueMap1Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.28
cm1110ConfigPriorityToEgressQueueMap2Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.29
cm1110ConfigPriorityToEgressQueueMap3Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.30
cm1110ConfigPriorityToEgressQueueMap4Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.31
cm1110ConfigPriorityToEgressQueueMap5Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.32
cm1110ConfigPriorityToEgressQueueMap6Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.33
cm1110ConfigPriorityToEgressQueueMap7Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.34
cm1110ConfigCopper8021pPriorityUse 802.1p tag priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.35
cm1110ConfigCopperIpTosPriorityUse IP TOS priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.36
cm1110ConfigCopperPriorityPrecedenceConfigure priority precedence. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.37
cm1110ConfigCopperCongestionPolicyConfigure priority congestion policy. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.38
cm1110ConfigCopperPriorityMap0Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.39
cm1110ConfigCopperPriorityMap1Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.40
cm1110ConfigCopperPriorityMap2Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.41
cm1110ConfigCopperPriorityMap3Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.42
cm1110ConfigCopperPriorityMap4Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.43
cm1110ConfigCopperPriorityMap5Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.44
cm1110ConfigCopperPriorityMap6Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.45
cm1110ConfigCopperPriorityMap7Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.46
cm1110ConfigCopperIngressLimitSet a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.47
cm1110ConfigCopperEgressLimitSet a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.48
cm1110ConfigCopperDiscardTaggedFramesEnable discarding of tagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.49
cm1110ConfigCopperDiscardUntaggedFramesEnable discarding of untagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.50
cm1110ConfigCopperDefaultVlanIdSet the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.51
cm1110ConfigCopperDefaultPrioritySet the default frame priority. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.52
cm1110ConfigCopperVlanTaggingActionSet the default tagging action. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.53
cm1110ConfigCopperFilterUnknownMulticastEnable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.54
cm1110ConfigCopperFilterUnknownUnicastEnable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.55
cm1110ConfigFiber8021pPriorityUse 802.1p tag priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.56
cm1110ConfigFiberIpTosPriorityUse IP TOS priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.57
cm1110ConfigFiberPriorityPrecedenceConfigure priority precedence. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.58
cm1110ConfigFiberCongestionPolicyConfigure priority congestion policy. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.59
cm1110ConfigFiberPriorityMap0Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.60
cm1110ConfigFiberPriorityMap1Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.61
cm1110ConfigFiberPriorityMap2Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.62
cm1110ConfigFiberPriorityMap3Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.63
cm1110ConfigFiberPriorityMap4Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.64
cm1110ConfigFiberPriorityMap5Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.65
cm1110ConfigFiberPriorityMap6Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.66
cm1110ConfigFiberPriorityMap7Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.67
cm1110ConfigFiberIngressLimitSet a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.68
cm1110ConfigFiberEgressLimitSet a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.69
cm1110ConfigFiberDiscardTaggedFramesEnable discarding of tagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.70
cm1110ConfigFiberDiscardUntaggedFramesEnable discarding of untagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.71
cm1110ConfigFiberDefaultVlanIdSet the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.72
cm1110ConfigFiberDefaultPrioritySet the default frame priority. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.73
cm1110ConfigFiberVlanTaggingActionSet the default tagging action. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.74
cm1110ConfigFiberFilterUnknownMulticastEnable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.75
cm1110ConfigFiberFilterUnknownUnicastEnable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.76
cm1110ConfigFiberSgmiiInterfaceThis object identifies whether fiber SGMII interface is enabled.rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.77
cm1110LedTableTable of CM-1110 type media converter module's LED status information.
SEQUENCE OF Cm1110LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3
cm1110LedEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
Cm1110LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1
cm1110LedSlotIndexThe Slot number the CM-1110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.2
cm1110LedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.3
cm1110LedFDFThis object identifies the status of the Full Duplex Fiber (FDF) LED on the media converter module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.4
cm1110LedLKFThis object identifies the status of the link fiber (LKF) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.5
cm1110LedCopperSpeedThis object identifies the status of the link copper speed (100/1000) LED on the management module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.6
cm1110LedFDCThis object identifies the status of the Full Duplex Copper (FDC) LED on the media converter module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.7
cm1110LedLKCThis object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.8
cm1110RateConvStatsTableTable of CM-1110 type media converter module's configuration and status type information.
SEQUENCE OF Cm1110RateConvStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4
cm1110RateConvStatsEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
Cm1110RateConvStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1
cm1110StatsSlotIndexThe Slot number the CM-1110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.2
cm1110MediaPortIndexMedia converter module port index indicating which media port the statistical counters are associated with.
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.3
cm1110PortInDiscardsA counter that counts the number of good, non-filtered frames that normally would have been forwarded, but could not due to lack of buffer space.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.4
cm1110PortInFilteredA counter that counts the number of good frames that were filtered due to ingress switch policy rules.ro
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.5
cm1110PortInGoodOctetsAn ingress counter that is the sum of lengths of all good Ethernet frames received on the media port.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.6
cm1110PortHCInGoodOctetsAn ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. This object is a 64-bit version of cm1110PortInGoodOctets.ro
Counter64
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.7
cm1110PortInBadOctetsAn ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port..ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.8
cm1110PortInUnicastsAn ingress counter that counts the number of good frames received that have a Unicast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.9
cm1110PortInBroadcastsAn ingress counter that counts the number of good frames received that have a Broadcast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.10
cm1110PortInMulticastsAn ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortInPauses or the cm1110PortInBroadcasts objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.11
cm1110PortInPausesAn ingress counter that counts the number of good frames reachieved that have a Pause destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.12
cm1110PortInUnderSizesAn ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.13
cm1110PortInFragmentsAn ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.14
cm1110PortInOversizesAn ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.15
cm1110PortInJabbersAn ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.16
cm1110PortInRxErrsAn ingress counter that counts the number of frames received with an RxErr signal from the PHY.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.17
cm1110PortInFcsErrsAn ingress counter that counts the number of frames received with a CRC error not counted in the cm1110PortInFragments, cm1110PortInFcsErr, or the cm1110PortInRxErr objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.18
cm1110PortPkts64OctetsA Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.19
cm1110PortPkts65to127OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.20
cm1110PortPkts128to255OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.21
cm1110PortPkts256to511OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.22
cm1110PortPkts512to1023OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.23
cm1110PortPkts1024toMaxOctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.24
cm1110PortOutOctetsAn Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.25
cm1110PortHCOutOctetsAn Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. This object is a 64-bit version of cm1110PortOutOctets.ro
Counter64
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.26
cm1110PortOutFilteredA counter that counts the number of good frames that were filtered due to egress switch policy rules.ro
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.27
cm1110PortOutUnicastsAn Egress counter that counts the number of good frames sent that have a Unicast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.28
cm1110PortOutBroadcastsAn Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.29
cm1110PortOutMulticastsAn Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortOutPauses or the cm1110PortOutBroadcasts objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.30
cm1110PortOutPausesAn Egress counter that counts the number of good frames reachieved that have a Pause destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.31
cm1110PortDeferredsAn Egress counter that counts the number of successfully transmitted frames that experienced no collisions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.32
cm1110PortCollisionsAn Egress counter that counts the number of collision events seen by the MAC not including those counted in cm1110PortSingles, cm1110PortMultiple , cm1110PortExcessives or cm1110PortLates objects. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.33
cm1110PortSinglesAn Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.34
cm1110PortMultiplesAn Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.35
cm1110PortExcessivesAn Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.36
cm1110PortLatesAn Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.37
cm1110PortOutFcsErrsAn Egress counter that counts the number frames transmitted with an invalid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.38
cm1110PortResetCountersAllows the resetting of all cm1110RateConvStats statistical counters for this port.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.39
cm1110RateConvAvctTableTable of CM-1110 type media converter module's
SEQUENCE OF Cm1110RateConvAvctEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5
cm1110RateConvAvctEntryEntries of the table, each relating to a separate fiber or copper port on the CM-1110 type media converter module.
Cm1110RateConvAvctEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1
cm1110AvctSlotIndexThe Slot number the CM-1110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.2
cm1110AvctStartSet this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.3
cm1110AvctStatusThis object identifies the state of the Advanced Virtual Cable Tester.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.4
cm1110AvctTxRxPair1ResultsTest result code returned from Virtual Cable Test of the Tx/Rx pair one.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.5
cm1110AvctTxRxPair1AmplitudeAmplitude of Tx/Rx pair one in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.6
cm1110AvctTxRxPair1DistanceDistance in meters to fault when test result codes for Tx/Rx pair one is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.7
cm1110AvctTxRxPair2ResultsTest result code returned from Virtual Cable Test of the Tx/Rx pair two.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.8
cm1110AvctTxRxPair2AmplitudeAmplitude of Tx/Rx pair two in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.9
cm1110AvctTxRxPair2DistanceDistance in meters to fault when test result codes for Tx/Rx pair two is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.10
cm1110AvctTxRxPair3ResultsTest result code returned from Virtual Cable Test of the Tx/Rx pair three.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.11
cm1110AvctTxRxPair3AmplitudeAmplitude of Tx/Rx pair three in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.12
cm1110AvctTxRxPair3DistanceDistance in meters to fault when test result codes for Tx/Rx pair three is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.13
cm1110AvctTxRxPair4ResultsTest result code returned from Virtual Cable Test of Tx/Rx pair four.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.14
cm1110AvctTxRxPair4AmplitudeAmplitude of Tx/Rx pair four in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.15
cm1110AvctTxRxPair4DistanceDistance in meters to fault when test result codes for Tx/Rx pair four is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.16
cm110RateConv
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4
cm110RateConvTableTable of CM-110 type media converter module's configuration and status type information.
SEQUENCE OF Cm110RateConvEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1
cm110RateConvEntryEntries of the table, each relating to a separate CM-110 type media converter module.
Cm110RateConvEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1
cm110SlotIndexThe Slot number the CM-110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.2
cm110ModelnameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.3
cm110ModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.4
cm110HwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.5
cm110HwJmp6AutoMDIXThis object identifies the media converter module's hardware Auto MDIX jumper settings.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.6
cm110HwSw1TpAutoNegotiationMedia converter module's current switch setting for copper auto-negotiation.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.7
cm110HwSw2LinkModeMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.8
cm110HwSw3FarEndFaultMedia converter module's current switch setting for Far End Fault.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.9
cm110HwSw4TpDuplexMedia converter module's current switch setting for copper duplex.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.10
cm110HwSw5TpSpeedMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.11
cm110HwSw6FiberDuplexMedia converter module's current switch setting for fiber duplex.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.12
cm110HwSw7LoopbackMedia converter module's current switch setting for fiber loopback mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.13
cm110FiberLinkStatusMedia converter module's current fiber link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.14
cm110FiberConnTypeMedia converter module's fiber port connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.15
cm110FiberSpeedMedia converter module's fiber port speed in megabits per second.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.16
cm110FiberFarEndFaultMedia converter module's current fiber Far End Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.17
cm110FiberReceiveStatusThis object identifies the status of whether light is being received on the fiber portrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.18
cm110FiberLoopBackThis object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.19
cm110CopperLinkStatusMedia converter module's current copper link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.20
cm110CopperConnTypeMedia converter module's copper connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.21
cm110CopperAutoNegStateMedia converter module's current copper auto-negotiation state.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.22
cm110CopperSpeedIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.23
cm110CopperDuplexIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.24
cm110CopperCrossOverIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.25
cm110CopperPauseIf copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause (flow control) setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.26
cm110CopperLPRFStatusMedia converter module's fiber Link Partner Remote Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.27
cm110ConfigTableTable of CM-110 type media converter module's configuration and status type information.
SEQUENCE OF Cm110ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2
cm110ConfigEntryEntries of the table, each relating to a separate CM-110 type media converter module.
Cm110ConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1
cm110ConfigSlotIndexThe Slot number the CM-110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.2
cm110ConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.3
cm110ConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.4
cm110ConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.5
cm110ConfigFiberFarEndFaultThis object identifies the Fiber Fault Alert setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.6
cm110ConfigMaxPacketSizeThis object identifies the media converter module's maximum packet size setting This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.7
cm110ConfigFiberPortNameThis object identifies a user definable name for the fiber port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.8
cm110ConfigFiberPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.9
cm110ConfigFiberDuplexThis object identifies the fiber port duplex setting.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.10
cm110ConfigCopperPortNameThis object identifies a user definable name for the copper port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.11
cm110ConfigCopperPortEnableThis object identifies whether the fiber port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.12
cm110ConfigCopperAutoNegotiationThis object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.13
cm110ConfigCopperAutoNegAdv10HDXThis object controls whether or the copper port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.14
cm110ConfigCopperAutoNegAdv10FDXThis object controls whether or the copper port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.15
cm110ConfigCopperAutoNegAdv100HDXThis object controls whether or the copper port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.16
cm110ConfigCopperAutoNegAdv100FDXThis object controls whether or the copper port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.17
cm110ConfigCopperSpeedThis object identifies the current copper speed in megabits per second. This object is ignored if auto-negotiation is enabled. This object is ignored if auto-negotiation is enabledrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.18
cm110ConfigCopperDuplexThis object identifies the copper duplex setting. This object is ignored if auto-negotiation is enabled This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.19
cm110ConfigCopperCrossOverThis object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set torw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.20
cm110ConfigCopperPauseThis object identifies the copper's pause (flow control) settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.21
cm110ConfigCopperExtendDistanceWhen using cable exceeding 100 meters, the 10BASE-T this feature should be enabled.rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.22
cm110ConfigUnidirectionalEthernetRestrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.23
cm110ConfigPriorityToEgressQueueMap0Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.24
cm110ConfigPriorityToEgressQueueMap1Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.25
cm110ConfigPriorityToEgressQueueMap2Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.26
cm110ConfigPriorityToEgressQueueMap3Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.27
cm110ConfigPriorityToEgressQueueMap4Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.28
cm110ConfigPriorityToEgressQueueMap5Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.29
cm110ConfigPriorityToEgressQueueMap6Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.30
cm110ConfigPriorityToEgressQueueMap7Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.31
cm110ConfigCopper8021pPriorityUse 802.1p tag priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.32
cm110ConfigCopperIpTosPriorityUse IP TOS priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.33
cm110ConfigCopperPriorityPrecedenceConfigure priority precedence. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.34
cm110ConfigCopperCongestionPolicyConfigure priority congestion policy. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.35
cm110ConfigCopperPriorityMap0Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.36
cm110ConfigCopperPriorityMap1Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.37
cm110ConfigCopperPriorityMap2Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.38
cm110ConfigCopperPriorityMap3Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.39
cm110ConfigCopperPriorityMap4Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.40
cm110ConfigCopperPriorityMap5Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.41
cm110ConfigCopperPriorityMap6Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.42
cm110ConfigCopperPriorityMap7Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.43
cm110ConfigCopperIngressLimitSet a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.44
cm110ConfigCopperEgressLimitSet a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.45
cm110ConfigCopperDiscardTaggedFramesEnable discarding of tagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.46
cm110ConfigCopperDiscardUntaggedFramesEnable discarding of untagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.47
cm110ConfigCopperDefaultVlanIdSet the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.48
cm110ConfigCopperDefaultPrioritySet the default frame priority. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.49
cm110ConfigCopperVlanTaggingActionSet the default tagging action. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.50
cm110ConfigCopperFilterUnknownMulticastEnable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.51
cm110ConfigCopperFilterUnknownUnicastEnable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.52
cm110ConfigFiber8021pPriorityUse 802.1p tag priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.53
cm110ConfigFiberIpTosPriorityUse IP TOS priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.54
cm110ConfigFiberPriorityPrecedenceConfigure priority precedence. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.55
cm110ConfigFiberCongestionPolicyConfigure priority congestion policy. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.56
cm110ConfigFiberPriorityMap0Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.57
cm110ConfigFiberPriorityMap1Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.58
cm110ConfigFiberPriorityMap2Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.59
cm110ConfigFiberPriorityMap3Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.60
cm110ConfigFiberPriorityMap4Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.61
cm110ConfigFiberPriorityMap5Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.62
cm110ConfigFiberPriorityMap6Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.63
cm110ConfigFiberPriorityMap7Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.64
cm110ConfigFiberIngressLimitSet a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.65
cm110ConfigFiberEgressLimitSet a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.66
cm110ConfigFiberDiscardTaggedFramesEnable discarding of tagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.67
cm110ConfigFiberDiscardUntaggedFramesEnable discarding of untagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.68
cm110ConfigFiberDefaultVlanIdSet the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.69
cm110ConfigFiberDefaultPrioritySet the default frame priority. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.70
cm110ConfigFiberVlanTaggingActionSet the default tagging action. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.71
cm110ConfigFiberFilterUnknownMulticastEnable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.72
cm110ConfigFiberFilterUnknownUnicastEnable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.73
cm110LedTableTable of CM-110 type media converter module's LED status information.
SEQUENCE OF Cm110LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3
cm110LedEntryEntries of the table, each relating to a separate CM-110 type media converter module.
Cm110LedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1
cm110LedSlotIndexThe Slot number the CM-110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.2
cm110LedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.3
cm110LedFDFThis object identifies the status of the Full Duplex Fiber (FDF) LED on the media converter module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.4
cm110LedLKFThis object identifies the status of the link fiber (LKF) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.5
cm110LedCopperSpeedThis object identifies the status of the link copper speed (100/1000) LED on the media converter module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.6
cm110LedFDCThis object identifies the status of the Full Duplex Copper (FDC) LED on the media converter module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.7
cm110LedLKCThis object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.8
cm110RateConvStatsTableTable of CM-110 media converter module's configuration and status type information.
SEQUENCE OF Cm110RateConvStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4
cm110RateConvStatsEntryEntries of the table, each relating to a separate CM-110 type media converter module.
Cm110RateConvStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1
cm110StatsSlotIndexThe Slot number the CM-110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.2
cm110MediaPortIndexMedia converter module port index indicating which media port the statistical counters are associated with.
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.3
cm110PortRxErrorsTotal number of bad frames received.ro
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.4
cm110PortTxCollisionsTotal number of TX collisions encountered.ro
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.5
cm110PortInFilteredA counter that counts the number of good frames that were filtered due to ingress switch policy rules.ro
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.6
cm110PortInGoodOctetsAn ingress counter that is the sum of lengths of all good Ethernet frames received on the media port.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.7
cm110PortInBadOctetsAn ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port..ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.8
cm110PortInUnicastsAn ingress counter that counts the number of good frames received that have a Unicast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.9
cm110PortInBroadcastsAn ingress counter that counts the number of good frames received that have a Broadcast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.10
cm110PortInMulticastsAn ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortInPauses or the cm1110PortInBroadcasts objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.11
cm110PortInPausesAn ingress counter that counts the number of good frames received that have a Pause destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.12
cm110PortInUnderSizesAn ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.13
cm110PortInFragmentsAn ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.14
cm110PortInOversizesAn ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the cm110ConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.15
cm110PortInJabbersAn ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the cm110ConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.16
cm110PortInMACRcvErrsAn ingress counter of the number of Rx errors on the receive side of the MACro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.17
cm110PortInFcsErrsAn ingress counter of the number of FCS Errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.18
cm110PortPkts64OctetsA Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.19
cm110PortPkts65to127OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.20
cm110PortPkts128to255OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.21
cm110PortPkts256to511OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.22
cm110PortPkts512to1023OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.23
cm110PortPkts1024toMaxOctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.24
cm110PortOutOctetsAn Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.25
cm110PortOutUnicastsAn Egress counter that counts the number of good frames sent that have a Unicast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.26
cm110PortOutBroadcastsAn Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.27
cm110PortOutMulticastsAn Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortOutPauses or the cm1110PortOutBroadcasts objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.28
cm110PortOutPausesAn Egress counter that counts the number of good frames received that have a Pause destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.29
cm110PortDeferredsAn Egress counter that counts the number of successfully transmitted frames that experienced no collsions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.30
cm110PortCollisionsAn Egress counter that counts the number of collision events seen by the MAC not including those counted in cm110PortSingles, cm110PortMultiple , cm1110PortExcessives or cm110PortLates objects. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.31
cm110PortSinglesAn Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.32
cm110PortMultiplesAn Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.33
cm110PortExcessivesAn Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.34
cm110PortLatesAn Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.35
cm110PortOutFcsErrsAn Egress counter that counts the number frames transmitted with an invalid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.36
cm110PortResetCountersAllows the resetting of all cm110RateConvStats statistical counters for this port.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.37
cm110RateConvVctTableTable of CM-110 type media converter module's
SEQUENCE OF Cm110RateConvVctEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5
cm110RateConvVctEntryEntries of the table, each relating to a separate fiber or copper port on the CM-110 type media converter module.
Cm110RateConvVctEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1
cm110VctSlotIndexThe Slot number the CM-1110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.2
cm110VctStartSet this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.3
cm110VctStatusThis object identifies the stat of the Advanced Virtual Cable Test.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.4
cm110VctTxPairResultsTest result code returned from Virtual Cable Test of the Tx pair.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.5
cm110VctTxPairAmplitudeAmplitude of Tx pair in Volts.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.6
cm110VctTxPairDistanceDistance in meters to fault when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.7
cm110VctRxPairResultsTest result code returned from Virtual Cable Test of the Rx pair.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.8
cm110VctRxPairAmplitudeAmplitude of Rx pair in Volts.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.9
cm110VctRxPairDistanceDistance in meters to fault when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.10
mcrMgt
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5
mcrMgtTableTable of MCR-MGT management module status type information.
SEQUENCE OF McrMgtEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1
mcrMgtEntryEntries of the table, each relating to a separate MCR-MGT type management module.
McrMgtEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1
mcrMgtSlotIndexThe Slot number the MCR-MGT module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.2
mcrMgtModelNameThis object identifies the model name of management module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.3
mcrMgtModelDescThis object identifies a static description of the management module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.4
mcrMgtFailSafeBootLoaderVerThis object identifies the fail-safe bootloader version of the management module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.5
mcrMgtUpTimeThis object identifies the time (in hundredths of a second) since the management module was last re-initialized.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.6
mcrMgtConsoleDSRThis object identifies the current status of the DSR signal, (active or inactive)ro
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.7
mcrMgtConfigTableTable of MCR-MGT management module Hardware configuration type information.
SEQUENCE OF McrMgtConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2
mcrMgtConfigEntryEntries of the table, each relating to a separate MCR-MGT type management module.
McrMgtConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1
mcrMgtConfigSlotIndexThe Slot number the MCR-MGT module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.2
mcrMgtConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.3
mcrMgtConfigEthSpeedDuplexDefine the Ethernet connection speed/duplex of the twisted pair interface.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.4
mcrMgtConfigEthCrossoverDefine the Ethernet connection crossover TX/RX Pair orientation of the twisted pair interface as auto(0), mdi(1) (straight through) or mdix(2) (crossed over).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.5
mcrMgtConfigConsolePortEnabledDetermines whether the management module's console port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.6
mcrMgtConfigConsoleSpeedSpecifies the baud rate of the console port; keep in mind that speed is affected by the length of the cable.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.7
mcrMgtConfigConsoleDataBitsSpecifies the number of bits in a byte.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.8
mcrMgtConfigConsoleParitySpecifies if you are using Even, Odd, or No parity on the console.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.9
mcrMgtConfigConsoleStopBitsSpecifies the number of stop bits that follow a byte.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.10
mcrMgtConfigConsoleFlowControlDefines whether the data flow is handled by the software (Soft), hardware (Hard), both or None.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.11
mcrMgtConfigConsoleMonitorDSRSpecifies whether the RS-232 signal DSR (Data Set Ready) should be monitored, for the console port. When DSR is monitored and the management module detects the DSR signal go inactive then the current console management session will be reset.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.12
mcrMgtLedTableTable of MCR-MGT management module LED information.
SEQUENCE OF McrMgtLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3
mcrMgtLedEntryEntries of the table, each relating to a separate MCR-MGT type management module.
McrMgtLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1
mcrMgtLedSlotIndexThe Slot number the MCR-MGT module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.2
mcrMgtLedPWRThis object identifies the status of the power (PWR) LED on the management module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to modulero
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.3
mcrMgtLedALMThis object identifies the status of the alarm (ALM) LED on the management module. Possible status values are: offNoAlarms(0) - Normal operating condition onRedAlarmsPresent(1) - System hardware or software alarms presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.4
mcrMgtLedLKCThis object identifies the status of the link copper (LKC) LED on the management module. Possible status values are: offLinkDown(0) - Copper link status is DOWN onGreenLinkUp(1) - Copper link status is UPro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.5
mcrMgtLedCopperSpeedThis object identifies the status of the link copper speed (100/1000) LED on the management module.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.6
mcrMgtEthStatsTableTable of MCR-MGT management module Ethernet status and statistics information.
SEQUENCE OF McrMgtEthStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4
mcrMgtEthStatsEntryAn entry in the Ethernet statistics table, each relating to an Ethernet interface.
McrMgtEthStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1
mgtEthSlotIndexThe Slot number the MCR-MGT module is currently inserted.
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.2
mgtEthStatsIfIndexThe Ethernet interface number.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.3
mgtEthStatsNameDisplays Ethernet interface name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.4
mgtEthStatsMacAddressDisplays the MAC address.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.5
mgtEthStatsStatusDisplays the Ethernet link status - down(0) or up(1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.6
mgtEthStatsSpeedDuplexCurrent status of the Ethernet connection speed/duplex twisted pair interface. When the management module does not know the pair speed/duplex, this variable has the value unknown(0).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.7
mgtEthStatsBroadcastThe management module's Ethernet Broadcast Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.8
mgtEthStatsDebugThe management module's Ethernet Debug Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.9
mgtEthStatsLoopbackThe management module's Ethernet Loopback Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.10
mgtEthStatsPointtoPointThe management module's Ethernet Point to Point Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.11
mgtEthStatsNoTrailersThe management module's Ethernet No Trailers Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.12
mgtEthStatsRunningThe management module's Ethernet Running Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.13
mgtEthStatsNoArpThe management module's Ethernet No Arp Protocol Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.14
mgtEthStatsPromiscuousThe management module's Ethernet Promiscuous Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.15
mgtEthStatsRxMulticastThe management module's Ethernet Receive all Multicast Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.16
mgtEthStatsMasterLoadBalancerThe management module's Ethernet Master Load Balancer Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.17
mgtEthStatsSlaveLoadBalancerThe management module's Ethernet Slave Load Balancer Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.18
mgtEthStatsMulticastThe management module's Ethernet Multicast Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.19
mgtEthStatsSetMediaThe management module's Ethernet Set Media Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.20
mgtEthStatsAutoMediaThe management module's Ethernet Auto Media Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.21
mgtEthStatsDynamicThe management module's Ethernet Dynamic Flags status.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.22
mgtEthStatsLocalAddressThe management module's Ethernet local IPv4 address.ro
IpAddress
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.23
mgtEthStatsSubnetMaskThe management module's Ethernet IPv4 subnet mask.ro
IpAddress
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.24
mgtEthStatsBroadcastAddressThe management module's Ethernet Broadcast address.ro
IpAddress
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.25
mgtEthStatsMtuThe management module's Ethernet MTU.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.26
mgtEthStatsTxQLenThe management module's Ethernet TX Queue Length.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.27
mgtEthStatsRxBytesThe management module's Ethernet RX Bytes count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.28
mgtEthStatsTxBytesThe management module's Ethernet TX Bytes count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.29
mgtEthStatsRxPacketsThe management module's Ethernet RX Packets count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.30
mgtEthStatsTxPacketsThe management module's Ethernet TX Packets count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.31
mgtEthStatsRxErrorsThe management module's Ethernet RX Packets Errors count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.32
mgtEthStatsTxPktErrorsThe management module's Ethernet TX Packets Errors count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.33
mgtEthStatsRxDroppedPktsThe management module's Ethernet RX Dropped packets count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.34
mgtEthStatsTxDroppedPktsThe management module's Ethernet TX Dropped packets count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.35
mgtEthStatsRxOverrunsThe management module's Ethernet RX Overruns countro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.36
mgtEthStatsTxOverrunsThe management module's Ethernet TX Overruns count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.37
mgtEthStatsRxFrameErrsThe management module's Ethernet RX Frame Errors count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.38
mgtEthStatsTxCarrierErrsThe management module's Ethernet TX Carrier Errors countro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.39
mgtEthStatsCollisionsThe management module's Ethernet Collisions count.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.40
cm1000mmFixed
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6
cm1000mmFixedTableTable of CM-1000MM type media converter module's status type information.
SEQUENCE OF Cm1000mmFixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1
cm1000mmFixedEntryEntries of the table, each relating to a separate CM-1000MM type media converter module.
Cm1000mmFixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1
cm1000mmSlotIndexThe Slot number the CM-1000MM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.2
cm1000mmModelnameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.3
cm1000mmModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.4
cm1000mmHwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.5
cm1000mmHwSw1FiberAutoNegMedia converter module's current switch setting for fiber Auto-Negotiation.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.6
cm1000mmHwSw2LinkModeMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.7
cm1000mmHwSw3FiberFaultAlertMedia converter module's current switch setting for Fiber Fault Alert.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.8
cm1000mmHwSw4Loopback1Media converter module's current switch setting for loopback (fiber port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.9
cm1000mmHwSw5Loopback2Media converter module's current switch setting for loopback (fiber port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.10
cm1000mmFiber1LinkStatusMedia converter module's current fiber link status (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.12
cm1000mmFiber1ConnTypeMedia converter module's fiber port connector type (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.13
cm1000mmFiber1AutoNegStateMedia converter module's current fiber auto-negotiation state (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.14
cm1000mmFiber1SpeedMedia converter module's fiber port speed in megabits per second (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.15
cm1000mmFiber1DuplexIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.16
cm1000mmFiber1PauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.17
cm1000mmFiber1LPRFStatusMedia converter module's fiber Link Partner Remote Fault status (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.18
cm1000mmFiber1ReceiveStatusThis object identifies the status of whether light is being received on the fiber port (port 1)rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.19
cm1000mmFiber2LinkStatusMedia converter module's current fiber link status (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.20
cm1000mmFiber2ConnTypeMedia converter module's fiber port connector type (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.21
cm1000mmFiber2AutoNegStateMedia converter module's current fiber auto-negotiation state (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.22
cm1000mmFiber2SpeedMedia converter module's fiber port speed in megabits per second (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.23
cm1000mmFiber2DuplexIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.24
cm1000mmFiber2PauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.25
cm1000mmFiber2LPRFStatusMedia converter module's fiber Link Partner Remote Fault status (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.26
cm1000mmFiber2ReceiveStatusThis object identifies the status of whether light is being received on the fiber port (port 2)rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.27
cm1000mmFiberLoopBackMedia converter module's current fiber loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.28
cm1000mmConfigTableTable of CM-1000MM type media converter module's configuration type information.
SEQUENCE OF Cm1000mmConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2
cm1000mmConfigEntryEntries of the table, each relating to a separate CM-1000MM type media converter module.
Cm1000mmConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1
cm1000mmConfigSlotIndexThe Slot number the CM-1000MM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.2
cm1000mmConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.3
cm1000mmConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.4
cm1000mmConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.5
cm1000mmConfigFiberFaultAlertThis object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.6
cm1000mmConfigJumboPacketsThis object identifies the Jumbo Packet setting for the media converter module present in the chassis.rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.7
cm1000mmConfigFiberAutoNegThis object identifies the wither fiber auto-negotiation is enabled for both ports. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.8
cm1000mmConfigFiber1PortNameThis object identifies a user definable name for the fiber port (port 1).rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.9
cm1000mmConfigFiber1PortEnableThis object identifies whether the fiber port is enabled (port 1).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.10
cm1000mmConfigFiber2PortNameThis object identifies a user definable name for the fiber port (port 2).rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.11
cm1000mmConfigFiber2PortEnableThis object identifies whether the fiber port is enabled (port 2).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.12
cm1000mmLedTableTable of CM-1000MM type media converter module's LED status information.
SEQUENCE OF Cm1000mmLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3
cm1000mmLedEntryEntries of the table, each relating to a separate CM-1000MM type media converter module.
Cm1000mmLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1
cm1000mmLedsSlotIndexThe Slot number the CM-1000 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.2
cm1000mmLedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.3
cm1000mmLedLK1This object identifies the status of the link fiber port 1 (LK1) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.4
cm1000mmLedLK2This object identifies the status of the link fiber port 2 (LK2) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.5
cm100mmFixed
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7
cm100mmFixedTableTable of CM-100MM type media converter module's configuration and status type information.
SEQUENCE OF Cm100mmFixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1
cm100mmFixedEntryEntries of the table, each relating to a separate CM-100MM type media converter module.
Cm100mmFixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1
cm100mmSlotIndexThe Slot number the CM-100MM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.2
cm100mmModelNameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.3
cm100mmModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.4
cm100mmHwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.5
cm100mmHwSw1LinkPassthroughMedia converter module's current switch setting for Link Passthrough.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.6
cm100mmHwSw2FarEndFaultMedia converter module's current switch setting for Far-End Fault.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.7
cm100mmHwSw3Loopback1Media converter module's current switch setting for Loopback (fiber port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.8
cm100mmHwSw4Loopback2Media converter module's current switch setting for Loopback (fiber port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.9
cm100mmFiber1LinkStatusMedia converter module's current fiber link status (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.12
cm100mmFiber1ConnTypeMedia converter module's fiber port connector type (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.13
cm100mmFiber1SpeedMedia converter module's fiber port speed in megabits per second (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.14
cm100mmFiber1FarEndFaultMedia converter module's current fiber Far End Fault status (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.15
cm100mmFiber1ReceiveStatusThis object identifies the status of whether light is being received on the fiber port (port 1)rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.16
cm100mmFiber2LinkStatusMedia converter module's current fiber link status (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.17
cm100mmFiber2ConnTypeMedia converter module's fiber port connector type (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.18
cm100mmFiber2SpeedMedia converter module's fiber port speed in megabits per second (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.19
cm100mmFiber2FarEndFaultMedia converter module's current fiber Far End Fault status (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.20
cm100mmFiber2ReceiveStatusThis object identifies the status of whether light is being received on the fiber port (port 2)rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.21
cm100mmFiberLoopBackThis object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.22
cm100mmConfigTableTable of CM-100MM type media converter module's configuration and status type information.
SEQUENCE OF Cm100mmConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2
cm100mmConfigEntryEntries of the table, each relating to a separate CM-100MM type media converter module.
Cm100mmConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1
cm100mmConfigSlotIndexThe Slot number the CM-100MM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.2
cm100mmConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.3
cm100mmConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.4
cm100mmConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.5
cm100mmConfigFiberFarEndFaultThis object identifies the fiber Far End Fault setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.6
cm100mmConfigFiber1PortNameThis object identifies a user definable name for the fiber port (port 1).rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.7
cm100mmConfigFiber1PortEnableThis object identifies whether the fiber port is enabled (port 2).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.8
cm100mmConfigFiber2PortNameThis object identifies a user definable name for the fiber port (port 2).rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.9
cm100mmConfigFiber2PortEnableThis object identifies whether the fiber port is enabled (port 2).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.10
cm100mmLedTableTable of CM-100MM type media converter module's LED status information.
SEQUENCE OF Cm100mmLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3
cm100mmLedEntryEntries of the table, each relating to a separate CM-100MM type media converter module.
Cm100mmLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1
cm100mmLedSlotIndexThe Slot number the CM-100MM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.2
cm100mmLedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.3
cm100mmLedLK1This object identifies the status of the link fiber port 1 (LK1) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.4
cm100mmLedLK2This object identifies the status of the link fiber port 2 (LK2) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.5
cm10gFixed
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8
cm10gFixedTableTable of CM-10G type media converter module's status type information.
SEQUENCE OF Cm10gFixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1
cm10gFixedEntryEntries of the table, each relating to a separate CM-10G type media converter module.
Cm10gFixedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1
cm10gSlotIndexThe Slot number the CM-10G type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.2
cm10gModelnameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.3
cm10gModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.4
cm10gHwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.5
cm10gHwSw1OperationModeMedia converter module's current switch setting for operation mode. Data mode is for normal data transmission.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.6
cm10gHwSw2LinkModeMedia converter module's current switch setting for Link Mode. If the Operation switch is set to Test, then this object indicates whether the port is in loopback or performing the build in link-test.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.7
cm10gHwSw3FiberFaultAlertMedia converter module's current switch setting for Fiber Fault Alert. If the Operation switch is set to Test, then this object indicates which port is in test modero
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.8
cm10gHwSw4Port1EdcModeThis oject indicates the current switch setting for EDC auto mode for port 1. This object only applies to SFP moudles.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.9
cm10gHwSw5Port2EdcModeThis oject indicates the current switch setting for EDC auto mode for port 2. This object only applies to SFP moudles.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.10
cm10gPort1LinkStatusMedia converter module's current fiber link status (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.11
cm10gPort1ConnTypeMedia converter module's fiber port connector type (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.12
cm10gPort1AutoNegStateMedia converter module's current fiber auto-negotiation state (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.13
cm10gPort1SpeedMedia converter module's fiber port speed in megabits per second (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.14
cm10gPort1DuplexIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.15
cm10gPort1PauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.16
cm10gPort1ReceiveStatusThis object identifies the status of whether light is being received on the fiber port (port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.17
cm10gPort2LinkStatusMedia converter module's current fiber link status (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.18
cm10gPort2ConnTypeMedia converter module's fiber port connector type (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.19
cm10gPort2AutoNegStateMedia converter module's current fiber auto-negotiation state (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.20
cm10gPort2SpeedMedia converter module's fiber port speed in megabits per second (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.21
cm10gPort2DuplexIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.22
cm10gPort2PauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.23
cm10gPort2ReceiveStatusThis object identifies the status of whether light is being received on the fiber port (port 2)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.24
cm10gPortLoopBackMedia converter module's current port loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.25
cm10gPortTestModeMedia converter module's current port test mode setting.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.26
cm10gConfigTableTable of CM-10G type media converter module's configuration type information.
SEQUENCE OF Cm10gConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2
cm10gConfigEntryEntries of the table, each relating to a separate CM-10G type media converter module.
Cm10gConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1
cm10gConfigSlotIndexThe Slot number the CM-10G type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.2
cm10gConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.3
cm10gConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.4
cm10gConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.5
cm10gConfigFiberFaultAlertThis object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.6
cm10gConfigFiberAutoNegThis object identifies the wither fiber auto-negotiation is enabled for both ports. This only applies if 1G SFP modules are in use. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.7
cm10gConfigPort1NameThis object identifies a user definable name for port 1.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.8
cm10gConfigPort1EnableThis object identifies whether port 1 is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.9
cm10gConfigPort1EdcModeThis object identifies the EDC mode for this port. This config option only applies for an SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.10
cm10gConfigPort1FecEnableThis object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.11
cm10gConfigPort1FecAmplitudeThis object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER(-128..127)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.12
cm10gConfigPort1FecPhaseThis object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER(-128..127)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.13
cm10gConfigPort1WavelengthEnableThis object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.14
cm10gConfigPort1WavelengthValueThis object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.15
cm10gConfigPort1ChannelEnableThis object identifies whether channel number fine tuning is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.16
cm10gConfigPort1ChannelNumberThis object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.17
cm10gConfigPort1TxDitherEnableThis object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.18
cm10gConfigPort1TxDitherValueThis object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.19
cm10gConfigPort2NameThis object identifies a user definable name for port 2.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.20
cm10gConfigPort2EnableThis object identifies whether port 2 is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.21
cm10gConfigPort2EdcModeThis object identifies the EDC mode for this port. This config option only applies for an SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.22
cm10gConfigPort2FecEnableThis object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.23
cm10gConfigPort2FecAmplitudeThis object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER(-128..127)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.24
cm10gConfigPort2FecPhaseThis object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER(-128..127)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.25
cm10gConfigPort2WavelengthEnableThis object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.26
cm10gConfigPort2WavelengthValueThis object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.27
cm10gConfigPort2ChannelEnableThis object identifies whether channel number fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.28
cm10gConfigPort2ChannelNumberThis object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.29
cm10gConfigPort2TxDitherEnableThis object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.30
cm10gConfigPort2TxDitherValueThis object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.31
cm10gLedTableTable of CM-10G type media converter module's LED status information.
SEQUENCE OF Cm10gLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3
cm10gLedEntryEntries of the table, each relating to a separate CM-10G type media converter module.
Cm10gLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1
cm10gLedsSlotIndexThe Slot number the CM-10G type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.2
cm10gLedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Loopback or Link-Test enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.3
cm10gLedLK1This object identifies the status of the port 1 link (LK1) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.4
cm10gLedLK2This object identifies the status of the port 2 link (LK2) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.5
exCM
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9
exCMTableTable of CM-1110 type media converter module's configuration and status type information.
SEQUENCE OF ExCMEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1
exCMEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
ExCMEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1
exCMSlotIndexThe Slot number the CM-1110 type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.2
exCMModelNameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.3
exCMModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.4
exCMHwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.5
exCMHwSw1AutoLocalRemoteMedia converter module's current switch setting for VDSL role.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.6
exCMHwSw2RateMedia converter module's current switch setting for VDSL rate/reach.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.7
exCMHwSw3SymmetricAsymmetricMedia converter module's current switch setting for VDSL band plan.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.8
exCMHwSw4SnrRatioMedia converter module's current switch setting for VDSL signal-to-noise ratio.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.9
exCMHwSw5LoopbackMedia converter module's current switch setting for VDSL loopback.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.10
exCMHwSw6EthAutoNegMedia converter module's current switch setting for ethernet auto-negotiation.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.11
exCMHwSw7EthSpeedMedia converter module's current switch setting for ethernet speed (when auto-negotiation is disabled).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.12
exCMHwSw8EthDuplexMedia converter module's current switch setting for ethernet duplex (when auto-negotiation is disabled).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.13
exCMHwSw9LinkModeMedia converter module's current switch setting for link mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.14
exCMHwSw10InterlinkFaultFeedbackMedia converter module's current switch setting for interlink fault feedback.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.15
exCMVdslLinkStatusMedia converter module's current VDSL link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.16
exCMVdslConnTypeMedia converter module's VDSL port connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.17
exCMVdslLoopBackThis object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.18
exCMVdslRoleThis object identifies the VDSL port's current role.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.19
exCMVdslProfileThis object identifies the VDSL port's current profile. This value has no meaning when the VDSL role is remote.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.20
exCMVdslBitswappingThis object identifies the VDSL port's current bitswapping status. This value has no meaning when the VDSL role is remote.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.21
exCMVdslStatusAttainableDataRateUpThis object identifies the VDSL port's attainable data rate (upstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.22
exCMVdslStatusAttainableDataRateDownThis object identifies the VDSL port's attainable data rate (downstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.23
exCMVdslStatusActualDataRateUpThis object identifies the VDSL port's actual data rate (upstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.24
exCMVdslStatusActualDataRateDownThis object identifies the VDSL port's actual data rate (downstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.25
exCMVdslStatusPrevDataRateUpThis object identifies the VDSL port's previous data rate (upstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.26
exCMVdslStatusPrevDataRateDownThis object identifies the VDSL port's previous data rate (downstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.27
exCMVdslStatusActualSnrUpThis object identifies the VDSL port's actual signal-to-noise ratio (upstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.28
exCMVdslStatusActualSnrDownThis object identifies the VDSL port's actual signal-to-noise ratio (downstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.29
exCMVdslStatusActualSnrUs0This object identifies the VDSL port's actual signal-to-noise ratio (upstream 0) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.30
exCMVdslStatusActualSnrUs1This object identifies the VDSL port's actual signal-to-noise ratio (upstream 1) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.31
exCMVdslStatusActualSnrDs1This object identifies the VDSL port's actual signal-to-noise ratio (downstream 1) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.32
exCMVdslStatusActualSnrUs2This object identifies the VDSL port's actual signal-to-noise ratio (upstream 2) in 0.2 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.33
exCMVdslStatusActualSnrDs2This object identifies the VDSL port's actual signal-to-noise ratio (downstream 2) in 0.2 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.34
exCMVdslStatusActualSnrUs3This object identifies the VDSL port's actual signal-to-noise ratio (upstream 3) in 0.3 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.35
exCMVdslStatusActualSnrDs3This object identifies the VDSL port's actual signal-to-noise ratio (downstream 3) in 0.3 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.36
exCMVdslStatusActualSnrUs4This object identifies the VDSL port's actual signal-to-noise ratio (upstream 4) in 0.4 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.37
exCMVdslStatusActualSnrDs4This object identifies the VDSL port's actual signal-to-noise ratio (downstream 4) in 0.4 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.38
exCMVdslStatusActualSignalAttenuationUpThis object identifies the VDSL port's actual signal attenuation (upstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.39
exCMVdslStatusActualSignalAttenuationDownThis object identifies the VDSL port's actual signal attenuation (downstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.40
exCMVdslStatusActualSignalAttenuationUs0This object identifies the VDSL port's actual signal attenuation (upstream 0) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.41
exCMVdslStatusActualSignalAttenuationUs1This object identifies the VDSL port's actual signal attenuation (upstream 1) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.42
exCMVdslStatusActualSignalAttenuationDs1This object identifies the VDSL port's actual signal attenuation (downstream 1) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.43
exCMVdslStatusActualSignalAttenuationUs2This object identifies the VDSL port's actual signal attenuation (upstream 2) in 0.2 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.44
exCMVdslStatusActualSignalAttenuationDs2This object identifies the VDSL port's actual signal attenuation (downstream 2) in 0.2 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.45
exCMVdslStatusActualSignalAttenuationUs3This object identifies the VDSL port's actual signal attenuation (upstream 3) in 0.3 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.46
exCMVdslStatusActualSignalAttenuationDs3This object identifies the VDSL port's actual signal attenuation (downstream 3) in 0.3 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.47
exCMVdslStatusActualSignalAttenuationUs4This object identifies the VDSL port's actual signal attenuation (upstream 4) in 0.4 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.48
exCMVdslStatusActualSignalAttenuationDs4This object identifies the VDSL port's actual signal attenuation (downstream 4) in 0.4 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.49
exCMVdslStatusActualLineAttenuationUpThis object identifies the VDSL port's actual line attenuation (upstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.50
exCMVdslStatusActualLineAttenuationDownThis object identifies the VDSL port's actual line attenuation (downstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.51
exCMVdslStatusActualLineAttenuationUs0This object identifies the VDSL port's actual line attenuation (upstream 0) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.52
exCMVdslStatusActualLineAttenuationUs1This object identifies the VDSL port's actual line attenuation (upstream 1) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.53
exCMVdslStatusActualLineAttenuationDs1This object identifies the VDSL port's actual line attenuation (downstream 1) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.54
exCMVdslStatusActualLineAttenuationUs2This object identifies the VDSL port's actual line attenuation (upstream 2) in 0.2 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.55
exCMVdslStatusActualLineAttenuationDs2This object identifies the VDSL port's actual line attenuation (downstream 2) in 0.2 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.56
exCMVdslStatusActualLineAttenuationUs3This object identifies the VDSL port's actual line attenuation (upstream 3) in 0.3 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.57
exCMVdslStatusActualLineAttenuationDs3This object identifies the VDSL port's actual line attenuation (downstream 3) in 0.3 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.58
exCMVdslStatusActualLineAttenuationUs4This object identifies the VDSL port's actual line attenuation (upstream 4) in 0.4 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.59
exCMVdslStatusActualLineAttenuationDs4This object identifies the VDSL port's actual line attenuation (downstream 4) in 0.4 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.60
exCMVdslStatusActualInterleaveDelayUpThis object identifies the VDSL port's actual interleave delay (upstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.61
exCMVdslStatusActualInterleaveDelayDownThis object identifies the VDSL port's actual interleave delay (downstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.62
exCMVdslStatusActualInpUpThis object identifies the VDSL port's actual INP (impulse noise protection) (upstream).ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.63
exCMVdslStatusActualInpDownThis object identifies the VDSL port's actual INP (impulse noise protection) (downstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.64
exCMVdslStatusActualInterleavingDepthUpThis object identifies the VDSL port's actual interleaving depth (upstream).ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.65
exCMVdslStatusActualInterleavingDepthDownThis object identifies the VDSL port's actual interleaving depth (impulse noise protection) (downstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.66
exCMVdslStatusActualInterleavingBlockUpThis object identifies the VDSL port's actual interleaving block (upstream).ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.67
exCMVdslStatusActualInterleavingBlockDownThis object identifies the VDSL port's actual interleaving block (impulse noise protection) (downstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.68
exCMVdslStatusActualTransmitPowerUpThis object identifies the VDSL port's actual transmit power (upstream) in 0.1 dBm.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.69
exCMVdslStatusActualTransmitPowerDownThis object identifies the VDSL port's actual transmit power (downstream) in 0.1 dBm.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.70
exCMVdslStatusMaxDataRateUpThis object identifies the VDSL port's maximum data rate (upstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.71
exCMVdslStatusMaxDataRateDownThis object identifies the VDSL port's maximum data rate (downstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.72
exCMVdslStatusMinDataRateUpThis object identifies the VDSL port's minimum data rate (upstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.73
exCMVdslStatusMinDataRateDownThis object identifies the VDSL port's minimum data rate (downstream) in kbps.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.74
exCMVdslStatusTargetSnrUpThis object identifies the VDSL port's target signal-to-noise ratio (upstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.75
exCMVdslStatusTargetSnrDownThis object identifies the VDSL port's target signal-to-noise ratio (downstream) in 0.1 dB.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.76
exCMVdslStatusMaxInterleaveDelayUpThis object identifies the VDSL port's maximum interleave delay (upstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.77
exCMVdslStatusMaxInterleaveDelayDownThis object identifies the VDSL port's maximum interleave delay (downstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.78
exCMVdslStatusMinInpUpThis object identifies the VDSL port's minimum INP (impulse noise protection) (upstream).ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.79
exCMVdslStatusMinInpDownThis object identifies the VDSL port's minimum INP (impulse noise protection) (downstream) in ms.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.80
exCMVdslRemoteLoopbackWrite remoteLoopbackOff(1) or remoteLoopbackOn(2) to this object to set the loopback state of the remote VDSL peer. This object's value represents the last loopback command sent to the peer.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.81
exCMVdslRemoteResetWrite resetRemotePeer(1) to this object to reset the remote VDSL peer. This object's value has no meaningrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.82
exCMEthernetLinkStatusMedia converter module's current Ethernet link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.83
exCMEthernetConnTypeMedia converter module's Ethernet connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.84
exCMEthernetAutoNegStateMedia converter module's current Ethernet auto-negotiation state.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.85
exCMEthernetSpeedIf Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.86
exCMEthernetDuplexIf Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.87
exCMEthernetCrossOverIf Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.88
exCMEthernetPauseEnhIf Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.89
exCMEthernetLPRFStatusMedia converter module's Ethernet Link Partner Remote Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.90
exCMEthernetAutoSpeedDownshiftThis object identifies the status of the Ethernet auto speed downshift feature. noDownshift indicates that an automatic downshift of the Ethernet speed has not occurred.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.91
exCMEthernetMDIThis object identifies the Ethernet port's crossover status: MDI or MDI-X.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.92
exCMVdslFirmwareVersionThis object identifies the version of the VDSL firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.93
exCMVdslFirmwareDateThis object identifies the date of the VDSL firmwarero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.94
exCMVdslFirmwareDateStringThis object identifies the version of the VDSL firmware, in human-readable format.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.95
exCMConfigTableTable of CM-1110 type media converter module's configuration type information.
SEQUENCE OF ExCMConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2
exCMConfigEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
ExCMConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1
exCMConfigSlotIndexThe Slot number the ex-CM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.2
exCMConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.3
exCMConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.4
exCMConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.5
exCMConfigInterlinkFaultFeedbackThis object identifies the interlink fault feedback setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.6
exCMConfigVdslPortNameThis object identifies a user definable name for the VDSL port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.7
exCMConfigVdslPortEnableThis object identifies whether the VDSL port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.8
exCMConfigVdslProfileModeThis object specifies how the VDSL profile is selected. Auto: select through exCMConfigVdslRate and exCMConfigVdslSymmetry Manual: select through exCMConfigVdslProfile.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.9
exCMConfigVdslRoleThis object specifies the VDSL role: auto, local (CO), or remote (CPE).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.10
exCMConfigVdslRateThis object specifies the VDSL rate/reach.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.11
exCMConfigVdslSymmetryThis object specifies the VDSL band plan or symmetry.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.12
exCMConfigVdslProfileThis object specifies the VDSL profile.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.13
exCMConfigVdslOverrideProfileThis object specifies whether to override advanced VDSL profile settings (e.g exCMConfigVdslSignalToNoiseRatioUp).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.14
exCMConfigVdslSignalToNoiseRatioUpThis object represents the advanced VDSL profile setting signal-to-noise ratio (upstream) in 0.1 dB.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.15
exCMConfigVdslMinDataRateUpThis object represents the advanced VDSL profile setting minimum data rate (upstream) in kbps.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.16
exCMConfigVdslMaxDataRateUpThis object represents the advanced VDSL profile setting maximum data rate (upstream) in kbps.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.17
exCMConfigVdslMaxInterleaveDelayUpThis object represents the advanced VDSL profile setting maximum delay (upstream) in ms.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.18
exCMConfigVdslMinInpUpThis object represents the advanced VDSL profile setting minimum INP (impulse noise protection) (upstream).rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.19
exCMConfigVdslSignalToNoiseRatioDownThis object represents the advanced VDSL profile setting signal-to-noise ratio (downstream) in 0.1 dB.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.20
exCMConfigVdslMinDataRateDownThis object represents the advanced VDSL profile setting minimum data rate (downstream) in kbps.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.21
exCMConfigVdslMaxDataRateDownThis object represents the advanced VDSL profile setting maximum data rate (downstream) in kbps.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.22
exCMConfigVdslMaxInterleaveDelayDownThis object represents the advanced VDSL profile setting maximum delay (downstream) in ms.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.23
exCMConfigVdslMinInpDownThis object represents the advanced VDSL profile setting minimum INP (impulse noise protection) (downstream).rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.24
exCMConfigVdslBitswappingThis object represents the advanced VDSL profile setting bitswapping.rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.25
exCMConfigVdslLowBandwidthAlarmUpThis object represents the VDSL low bandwidth alarm threshold (upstream) in kbps.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.26
exCMConfigVdslLowBandwidthAlarmDownThis object represents the VDSL low bandwidth alarm threshold (downstream) in kbps.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.27
exCMConfigEthernetPortNameThis object identifies a user definable name for the ethernet port.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.28
exCMConfigEthernetPortEnableThis object identifies whether the VDSL port is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.29
exCMConfigEthernetAutoNegotiationThis object identifies the whether ethernet auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.30
exCMConfigEthernetAutoNegAdv10HDXThis object controls whether or the ethernet port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.31
exCMConfigEthernetAutoNegAdv10FDXThis object controls whether or the ethernet port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.32
exCMConfigEthernetAutoNegAdv100HDXThis object controls whether or the ethernet port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.33
exCMConfigEthernetAutoNegAdv100FDXThis object controls whether or the ethernet port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.34
exCMConfigEthernetAutoNegAdv1000FDXThis object controls whether or the ethernet port advertises willingness to connect at 1000Mbps, full duplex. This setting is ignored when auto-negotiation is disabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.35
exCMConfigEthernetSpeedIf ethernet auto-negotiation is disabled then this object identifies the configured cooper speed. 1000 Mbps speed can only be auto negotiated. If ethernet auto-negotiation is enabled then this object is ignored. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.36
exCMConfigEthernetDuplexIf ethernet auto-negotiation is disabled then this object identifies the duplex setting for 10 & 100 Mbps for the ethernet port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.37
exCMConfigEthernetCrossOverThis object identifies the ethernet MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set torw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.38
exCMConfigEthernetPauseEnhThis object identifies the ethernet pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.39
exCMConfigEthernetAutoSpeedDownshiftThis object identifies the number of times the PHY attempts to establish a Gigabit link before the PHY downshift to the next highest speed. A value of 0 indicates the auto downshift is disabledrw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.40
exCMConfigEthernet10BaseTDistanceWhen using cable exceeding 100 meters in 10BASE-T mode this feature should be set to extended(1).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.41
exCMConfigUnidirectionalEthernetRestrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.42
exCMConfigPriorityToEgressQueueMap0Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.43
exCMConfigPriorityToEgressQueueMap1Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.44
exCMConfigPriorityToEgressQueueMap2Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.45
exCMConfigPriorityToEgressQueueMap3Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.46
exCMConfigPriorityToEgressQueueMap4Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.47
exCMConfigPriorityToEgressQueueMap5Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.48
exCMConfigPriorityToEgressQueueMap6Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.49
exCMConfigPriorityToEgressQueueMap7Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.50
exCMConfigEthernet8021pPriorityUse 802.1p tag priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.51
exCMConfigEthernetIpTosPriorityUse IP TOS priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.52
exCMConfigEthernetPriorityPrecedenceConfigure priority precedence. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.53
exCMConfigEthernetCongestionPolicyConfigure priority congestion policy. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.54
exCMConfigEthernetPriorityMap0Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.55
exCMConfigEthernetPriorityMap1Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.56
exCMConfigEthernetPriorityMap2Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.57
exCMConfigEthernetPriorityMap3Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.58
exCMConfigEthernetPriorityMap4Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.59
exCMConfigEthernetPriorityMap5Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.60
exCMConfigEthernetPriorityMap6Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.61
exCMConfigEthernetPriorityMap7Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.62
exCMConfigEthernetIngressLimitSet a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.63
exCMConfigEthernetEgressLimitSet a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.64
exCMConfigEthernetDiscardTaggedFramesEnable discarding of tagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.65
exCMConfigEthernetDiscardUntaggedFramesEnable discarding of untagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.66
exCMConfigEthernetDefaultVlanIdSet the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.67
exCMConfigEthernetDefaultPrioritySet the default frame priority. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.68
exCMConfigEthernetVlanTaggingActionSet the default tagging action. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.69
exCMConfigEthernetFilterUnknownMulticastEnable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.70
exCMConfigEthernetFilterUnknownUnicastEnable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.71
exCMConfigVdsl8021pPriorityUse 802.1p tag priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.72
exCMConfigVdslIpTosPriorityUse IP TOS priority. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.73
exCMConfigVdslPriorityPrecedenceConfigure priority precedence. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.74
exCMConfigVdslCongestionPolicyConfigure priority congestion policy. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.75
exCMConfigVdslPriorityMap0Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.76
exCMConfigVdslPriorityMap1Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.77
exCMConfigVdslPriorityMap2Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.78
exCMConfigVdslPriorityMap3Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.79
exCMConfigVdslPriorityMap4Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.80
exCMConfigVdslPriorityMap5Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.81
exCMConfigVdslPriorityMap6Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.82
exCMConfigVdslPriorityMap7Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.83
exCMConfigVdslIngressLimitSet a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.84
exCMConfigVdslEgressLimitSet a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.85
exCMConfigVdslDiscardTaggedFramesEnable discarding of tagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.86
exCMConfigVdslDiscardUntaggedFramesEnable discarding of untagged frames. (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.87
exCMConfigVdslDefaultVlanIdSet the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.88
exCMConfigVdslDefaultPrioritySet the default frame priority. (This feature may require a media converter module firmware upgrade).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.89
exCMConfigVdslVlanTaggingActionSet the default tagging action. (This feature may require a media converter module firmware upgrade).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.90
exCMConfigVdslFilterUnknownMulticastEnable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.91
exCMConfigVdslFilterUnknownUnicastEnable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade).rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.92
exCMConfigVdslFastModeThis object represents the VDSL fast mode setting.rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.93
exCMLedTableTable of CM-1110 type media converter module's LED status information.
SEQUENCE OF ExCMLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3
exCMLedEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
ExCMLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1
exCMLedSlotIndexThe Slot number of the module
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.2
exCMLedILNKThis object identifies the status of the ILNK (InterLink) LED on the media converter module. Possible status values are: slowBlinkingGreen(1) - ILNK port is idle or handshaking fastBlinkingGreen(2) - ILNK port is training green(3) - ILNK port is upro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.3
exCMLedLOCThis object identifies the status of the Local (LOC) LED on the media converter module. When this LED is green, it indicates that the InterLink port's VDSL role is local.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.4
exCMLedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - InterLink loopback enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.5
exCMLedETHThis object identifies the status of the ETH (Ethernet) LED on the media converter module. Possible status values are: off(0) - ETH port is down slowBlinkingGreen(1) - ETH port is down, due to the VDSL port or peer copper ethernet port being down green(2) - ETH port is upro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.6
exCMLedRMTThis object identifies the status of the Remote (RMT) LED on the media converter module. When this LED is green, it indicates that the InterLink port's VDSL role is remote.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.7
exCMStatsTableTable of CM-1110 type media converter module's configuration and status type information.
SEQUENCE OF ExCMStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4
exCMStatsEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
ExCMStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1
exCMStatsSlotIndexThe Slot number the ex-1CM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.2
exCMMediaPortIndexMedia converter module port index indicating which media port the statistical counters are associated with.
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.3
exCMPortInDiscardsA counter that counts the number of good, non-filtered frames that normally would have been forwarded, but could not due to lack of buffer space.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.4
exCMPortInFilteredA counter that counts the number of good frames that were filtered due to ingress switch policy rules.ro
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.5
exCMPortInGoodOctetsAn ingress counter that is the sum of lengths of all good Ethernet frames received on the media port.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.6
exCMPortHCInGoodOctetsAn ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. This object is a 64-bit version of exCMPortInGoodOctets.ro
Counter64
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.7
exCMPortInBadOctetsAn ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port..ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.8
exCMPortInUnicastsAn ingress counter that counts the number of good frames received that have a Unicast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.9
exCMPortInBroadcastsAn ingress counter that counts the number of good frames received that have a Broadcast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.10
exCMPortInMulticastsAn ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the exCMPortInPauses or the exCMPortInBroadcasts objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.11
exCMPortInPausesAn ingress counter that counts the number of good frames reachieved that have a Pause destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.12
exCMPortInUnderSizesAn ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.13
exCMPortInFragmentsAn ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.14
exCMPortInOversizesAn ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the exCMConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.15
exCMPortInJabbersAn ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the exCMConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.16
exCMPortInRxErrsAn ingress counter that counts the number of frames received with an RxErr signal from the PHY.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.17
exCMPortInFcsErrsAn ingress counter that counts the number of frames received with a CRC error not counted in the exCMPortInFragments, exCMPortInFcsErr, or the exCMPortInRxErr objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.18
exCMPortPkts64OctetsA Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.19
exCMPortPkts65to127OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.20
exCMPortPkts128to255OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.21
exCMPortPkts256to511OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.22
exCMPortPkts512to1023OctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.23
exCMPortPkts1024toMaxOctetsA Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the exCMConfigMaxPacketsSize object.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.24
exCMPortOutOctetsAn Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.25
exCMPortHCOutOctetsAn Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. This object is a 64-bit version of exCMPortOutOctets.ro
Counter64
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.26
exCMPortOutFilteredA counter that counts the number of good frames that were filtered due to egress switch policy rules.ro
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.27
exCMPortOutUnicastsAn Egress counter that counts the number of good frames sent that have a Unicast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.28
exCMPortOutBroadcastsAn Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.29
exCMPortOutMulticastsAn Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the exCMPortOutPauses or the exCMPortOutBroadcasts objects.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.30
exCMPortOutPausesAn Egress counter that counts the number of good frames reachieved that have a Pause destination MAC address.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.31
exCMPortDeferredsAn Egress counter that counts the number of successfully transmitted frames that experienced no collisions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.32
exCMPortCollisionsAn Egress counter that counts the number of collision events seen by the MAC not including those counted in exCMPortSingles, exCMPortMultiple , exCMPortExcessives or exCMPortLates objects. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.33
exCMPortSinglesAn Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.34
exCMPortMultiplesAn Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.35
exCMPortExcessivesAn Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.36
exCMPortLatesAn Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.37
exCMPortOutFcsErrsAn Egress counter that counts the number frames transmitted with an invalid FCS.ro
Counter32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.38
exCMPortResetCountersAllows the resetting of all exCMStats statistical counters for this port.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.39
exCMVdslStatsTableTable of CM-1110 type media converter module's configuration and status type information.
SEQUENCE OF ExCMVdslStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5
exCMVdslStatsEntryEntries of the table, each relating to a separate CM-1110 type media converter module.
ExCMVdslStatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1
exCMVdslStatsSlotIndexThe Slot number the ex-1CM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.2
exCMVdslStatsMediaPortIndexMedia converter module port index indicating which media port the statistical counters are associated with.
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.3
exCMVdslStatsTimePeriodMedia converter module port index indicating which media port the statistical counters are associated with.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.4
exCMVdslStatsFullInitLocalThe VDSL port's fully initialized (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.5
exCMVdslStatsCodeViolationLocalThe VDSL port's code violation (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.6
exCMVdslStatsCorrectedLocalThe VDSL port's corrected (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.7
exCMVdslStatsFecSecsLocalThe VDSL port's forward error correction seconds (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.8
exCMVdslStatsErroredSecsLocalThe VDSL port's errored seconds (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.9
exCMVdslStatsSeverelyErroredSecsLocalThe VDSL port's severely errored seconds (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.10
exCMVdslStatsLossOfSignalSecsLocalThe VDSL port's loss of signal seconds (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.11
exCMVdslStatsUnavailableSecsLocalThe VDSL port's unavailable seconds (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.12
exCMVdslStatsTimeElapsedLocalThe VDSL port's elapsed time in seconds (local) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.13
exCMVdslStatsFullInitRemoteThe VDSL port's fully initialized (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.14
exCMVdslStatsCodeViolationRemoteThe VDSL port's code violation (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.15
exCMVdslStatsCorrectedRemoteThe VDSL port's corrected (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.16
exCMVdslStatsFecSecsRemoteThe VDSL port's forward error correction seconds (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.17
exCMVdslStatsErroredSecsRemoteThe VDSL port's errored seconds (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.18
exCMVdslStatsSeverelyErroredSecsRemoteThe VDSL port's severely errored seconds (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.19
exCMVdslStatsLossOfSignalSecsRemoteThe VDSL port's loss of signal seconds (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.20
exCMVdslStatsUnavailableSecsRemoteThe VDSL port's unavailable seconds (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.21
exCMVdslStatsTimeElapsedRemoteThe VDSL port's elapsed time in seconds (remote) count.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.22
exCMAvctTableTable of ex-CM media converter modules.
SEQUENCE OF ExCMAvctEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6
exCMAvctEntryEntries of the table, each relating to a copper Ethernet port on the eX-CM type media converter module.
ExCMAvctEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1
exCMAvctSlotIndexThe Slot number the eX-CM type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.2
exCMAvctStartSet this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.3
exCMAvctStatusThis object identifies the state of the Advanced Virtual Cable Tester.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.4
exCMAvctTxRxPair1ResultsTest result code returned from Virtual Cable Test of the Tx/Rx pair one.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.5
exCMAvctTxRxPair1AmplitudeAmplitude of Tx/Rx pair one in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.6
exCMAvctTxRxPair1DistanceDistance in meters to fault when test result codes for Tx/Rx pair one is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.7
exCMAvctTxRxPair2ResultsTest result code returned from Virtual Cable Test of the Tx/Rx pair two.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.8
exCMAvctTxRxPair2AmplitudeAmplitude of Tx/Rx pair two in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.9
exCMAvctTxRxPair2DistanceDistance in meters to fault when test result codes for Tx/Rx pair two is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.10
exCMAvctTxRxPair3ResultsTest result code returned from Virtual Cable Test of the Tx/Rx pair three.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.11
exCMAvctTxRxPair3AmplitudeAmplitude of Tx/Rx pair three in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.12
exCMAvctTxRxPair3DistanceDistance in meters to fault when test result codes for Tx/Rx pair three is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.13
exCMAvctTxRxPair4ResultsTest result code returned from Virtual Cable Test of Tx/Rx pair four.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.14
exCMAvctTxRxPair4AmplitudeAmplitude of Tx/Rx pair four in millivolts when test result codes is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.15
exCMAvctTxRxPair4DistanceDistance in meters to fault when test result codes for Tx/Rx pair four is short or open.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.16
cm10gt
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10
cm10gtTableTable of CM-10G type media converter module's status type information.
SEQUENCE OF Cm10gtEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1
cm10gtEntryEntries of the table, each relating to a separate CM-10G type media converter module.
Cm10gtEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1
cm10gtSlotIndexThe Slot number the CM-10G type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.2
cm10gtModelnameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.3
cm10gtModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.4
cm10gtHwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.5
cm10gtHwSw1OperationModeMedia converter module's current switch setting for operation mode. Data mode is for normal data transmission.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.6
cm10gtHwSw2LinkModeMedia converter module's current switch setting for Link Mode. If the Operation switch is set to Test, then this object indicates whether the port is in loopback or performing the build in link-test.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.7
cm10gtHwSw3FiberFaultAlertMedia converter module's current switch setting for Fiber Fault Alert. If the Operation switch is set to Test, then this object indicates which port is in test modero
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.8
cm10gtHwSw4EnergyEfficentEthernetThis object indicates the current switch setting for Energy Efficient Ethernet on port 2.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.9
cm10gtHwSw5UnusedThis object indicates the current switch setting for dip switch 5, which is unused.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.10
cm10gtPort1LinkStatusMedia converter module's current fiber link status (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.11
cm10gtPort1ConnTypeMedia converter module's fiber port connector type (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.12
cm10gtPort1AutoNegStateMedia converter module's current fiber auto-negotiation state (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.13
cm10gtPort1SpeedMedia converter module's fiber port speed in megabits per second (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.14
cm10gtPort1DuplexIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.15
cm10gtPort1PauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.16
cm10gtPort1ReceiveStatusThis object identifies the status of whether light is being received on the fiber port (port 1)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.17
cm10gtPort1LPRFStatusMedia converter module's Link Partner Remote Fault status (port 1). This object only applies to SFP modules running at 1G, with auto-negotiation enabled.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.18
cm10gtPort2LinkStatusMedia converter module's current fiber link status (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.19
cm10gtPort2ConnTypeMedia converter module's fiber port connector type (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.20
cm10gtPort2AutoNegStateMedia converter module's current fiber auto-negotiation state (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.21
cm10gtPort2SpeedMedia converter module's fiber port speed in megabits per second (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.22
cm10gtPort2DuplexIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.23
cm10gtPort2PauseEnhIf fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2)ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.24
cm10gtPort2LPRFStatusMedia converter module's copper Link Partner Remote Fault status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.25
cm10gtPortLoopBackMedia converter module's current port loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.26
cm10gtPortTestModeMedia converter module's current port test mode setting.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.27
cm10gtConfigTableTable of CM-10G type media converter module's configuration type information.
SEQUENCE OF Cm10gtConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2
cm10gtConfigEntryEntries of the table, each relating to a separate CM-10G type media converter module.
Cm10gtConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1
cm10gtConfigSlotIndexThe Slot number the CM-10G type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.2
cm10gtConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.3
cm10gtConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.4
cm10gtConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.5
cm10gtConfigFiberFaultAlertThis object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.6
cm10gtConfigFiberAutoNegThis object identifies the wither fiber auto-negotiation is enabled for both ports. This only applies if 1G SFP modules are in use. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.7
cm10gtConfigPort1NameThis object identifies a user definable name for port 1.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.8
cm10gtConfigPort1EnableThis object identifies whether port 1 is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.9
cm10gtConfigPort1FecEnableThis object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.10
cm10gtConfigPort1FecAmplitudeThis object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER(-128..127)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.11
cm10gtConfigPort1FecPhaseThis object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER(-128..127)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.12
cm10gtConfigPort1WavelengthEnableThis object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.13
cm10gtConfigPort1WavelengthValueThis object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.14
cm10gtConfigPort1ChannelEnableThis object identifies whether channel number fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.15
cm10gtConfigPort1ChannelNumberThis object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.16
cm10gtConfigPort1TxDitherEnableThis object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.17
cm10gtConfigPort1TxDitherValueThis object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.18
cm10gtConfigPort2NameThis object identifies a user definable name for port 2.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.19
cm10gtConfigPort2EnableThis object identifies whether port 2 is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.20
cm10gtConfigPort2CopperDuplexThis object identifies the duplex settings for the copper port.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.21
cm10gtConfigPort2CopperPauseEnhThis object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.22
cm10gtConfigPort2CopperEnergyEfficientEthernetThis object identifies the copper Energy-Efficient Ethernet setting for the media converter module present in the chassis.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.23
cm10gtLedTableTable of CM-10G type media converter module's LED status information.
SEQUENCE OF Cm10gtLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3
cm10gtLedEntryEntries of the table, each relating to a separate CM-10G type media converter module.
Cm10gtLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1
cm10gtLedsSlotIndexThe Slot number the CM-10G type module is currently insertedro
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.2
cm10gtLedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Loopback or Link-Test enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.3
cm10gtLedLK1This object identifies the status of the port 1 link (LK1) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.4
cm10gtLedLK2This object identifies the status of the port 2 link (LK2) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.5
cm4gpt
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11
cm4gptTableTable of CM-4GPT type media converter module's status type information.
SEQUENCE OF Cm4gptEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1
cm4gptEntryEntries of the table, each relating to a separate CM-4GPT type media converter module.
Cm4gptEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1
cm4gptSlotIndexThe Slot number the CM-4GPT type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.2
cm4gptModelnameThis object identifies the model of media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.3
cm4gptModelDescThis object identifies a static description of the media converter module present in the chassisro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.4
cm4gptHwJmp5ConfigModeThis object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.5
cm4gptHwSw1LinkModeMedia converter module's current switch setting for Link Mode.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.6
cm4gptHwSw2FiberFaultAlertMedia converter module's current switch setting for Fiber Fault Alert.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.7
cm4gptHwSw3RateSelectMedia converter module's current switch setting for Rate Select.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.8
cm4gptHwSw4UnusedThis object indicates the current switch setting for the 4th, unused switch.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.9
cm4gptPort1LinkStatusMedia converter module's current fiber link status (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.10
cm4gptPort1ConnTypeMedia converter module's fiber port connector type (port 1).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.11
cm4gptPort2LinkStatusMedia converter module's current fiber link status (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.12
cm4gptPort2ConnTypeMedia converter module's fiber port connector type (port 2).ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.13
cm4gptConfigTableTable of CM-4GPT type media converter module's configuration type information.
SEQUENCE OF Cm4gptConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2
cm4gptConfigEntryEntries of the table, each relating to a separate CM-4GPT type media converter module.
Cm4gptConfigEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1
cm4gptConfigSlotIndexThe Slot number the CM-4GPT type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.2
cm4gptConfigStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.3
cm4gptConfigModuleNameThis object identifies a user configurable name for the media converter module present in the chassis.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.4
cm4gptConfigLinkModeThis object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.5
cm4gptConfigFiberFaultAlertThis object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.6
cm4gptConfigRateSelectThis object identifies the Rate Select setting for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.7
cm4gptConfigPort1NameThis object identifies a user definable name for port 1.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.8
cm4gptConfigPort1EnableThis object identifies whether port 1 is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.9
cm4gptConfigPort2NameThis object identifies a user definable name for port 2.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.10
cm4gptConfigPort2EnableThis object identifies whether port 2 is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.11
cm4gptLedTableTable of CM-4GPT type media converter module's LED status information.
SEQUENCE OF Cm4gptLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3
cm4gptLedEntryEntries of the table, each relating to a separate CM-4GPT type media converter module.
Cm4gptLedEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1
cm4gptLedsSlotIndexThe Slot number the CM-4GPT type module is currently inserted
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.2
cm4gptLedPWRThis object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Loopback or Link-Test enabledro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.3
cm4gptLedLK1This object identifies the status of the port 1 link (LK1) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.4
cm4gptLedLK2This object identifies the status of the port 2 link (LK2) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link presentro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.5
mcrSfpDmiModuleTableTable of SFP Diagnostic Monitoring Interface information for Optical Transceivers
SEQUENCE OF McrSfpDmiModuleEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.5
mcrSfpDmiModuleEntryEntries of the table, each relating to a separate SFP module.
McrSfpDmiModuleEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1
sfpDmiSlotIndexThe Slot number of the media converter module containing this SFP/XFP
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.2
sfpDmiMediaPortIndexMedia converter module port index.
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.3
sfpDmiStatusThis object identifies the status of the SFP module. If sfpCommFailed bit is set then the rest of the data in this entry is invalidro
Bits
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.4
sfpDmiConnectorTypeThis object identifies the SFP DMI connector type.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.5
sfpDmiNominalBitRateThis object identifies the SFP DMI nominal bit rate of fiber interface, in megabits per second.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.6
sfpDmiLinkReach9125This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 9 micron (125 micron jacket) single-mode fiber.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.7
sfpDmiLinkReach50125This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 50 micron (125 micron jacket) multi-mode fiber.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.8
sfpDmiLinkReach625125This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 62.5 micron (125 micron jacket) multi-mode fiber.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.9
sfpDmiFiberWaveLengthThis object identifies the wavelength of the fiber interface's optical transceiver, in nanometers.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.10
sfpDmiCurrentTempStateThis object identifies the current alarm status for SFP DMI internally measured temperature.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.11
sfpDmiRealTimeTempThis object identifies the SFP DMI real time temperature. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.12
sfpDmiHighTempWarnThis object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.13
sfpDmiHighTempAlarmThis object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.14
sfpDmiLowTempWarnThis object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.15
sfpDmiLowTempAlarmThis object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.16
sfpDmiCurrentVoltStateThis object identifies current alarm status for SFP DMI internally measured voltage.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.17
sfpDmiRealTimeVoltThis object identifies the SFP DMI real time voltage in Volts.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.18
sfpDmiHighVoltWarnThis object identifies the SFP DMI high voltage warning threshold in Voltsro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.19
sfpDmiHighVoltAlarmThis object identifies the SFP DMI high voltage warning threshold in Voltsro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.20
sfpDmiLowVoltWarnThis object identifies the SFP DMI high voltage warning threshold in Voltsro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.21
sfpDmiLowVoltAlarmThis object identifies the SFP DMI high voltage warning threshold in Voltsro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.22
sfpDmiCurrentTxBiasStateThis object identifies current alarm status for SFP DMI internally measured transmit bias current in milliamps.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.23
sfpDmiRealTimeTxBiasThis object identifies the SFP DMI high TX Bias current in milliamps.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.24
sfpDmiHighTxBiasWarnThis object identifies the SFP DMI high TX Bias current warning threshold in milliamps.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.25
sfpDmiHighTxBiasAlarmThis object identifies the SFP DMI high TX Bias current alarm threshold in milliamps.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.26
sfpDmiLowTxBiasWarnThis object identifies the SFP DMI low TX Bias current warning threshold in milliamps.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.27
sfpDmiLowTxBiasAlarmThis object identifies the SFP DMI low TX Bias current alarm threshold in milliamps.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.28
sfpDmiCurrentTxPowerStateThis object identifies current alarm status for SFP DMI internally measured transmit power.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.29
sfpDmiRealTimeTxPowerThis object identifies the SFP DMI real time TX output power. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.30
sfpDmiHighTxPowerWarnThis object identifies the SFP DMI high TX output power warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.31
sfpDmiHighTxPowerAlarmThis object identifies the SFP DMI high TX output power alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.32
sfpDmiLowTxPowerWarnThis object identifies the SFP DMI low TX output power warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.33
sfpDmiLowTxPowerAlarmThis object identifies the SFP DMI low TX output power alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.34
sfpDmiCurrentRxPowerStateThis object identifies current alarm status for SFP DMI internally measured receive power.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.35
sfpDmiRealTimeRxPowerThis object identifies the SFP DMI real time RX received optical power. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.36
sfpDmiHighRxPowerWarnThis object identifies the SFP DMI high RX received optical warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.37
sfpDmiHighRxPowerAlarmThis object identifies the SFP DMI high RX received optical alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.38
sfpDmiLowRxPowerWarnThis object identifies the SFP DMI low RX received optical warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.39
sfpDmiLowRxPowerAlarmThis object identifies the SFP DMI low RX received optical alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.40
sfpDmiStatus2This object identifies the status of the SFP module. If sfpCommFailed value is set then the rest of the data in this entry is invalid 0x80 - sfpModuleInserted 0x40 - sfpCommFailed 0x20 - sfpDmiSupportedro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.41
sfpDmiVendorSerialNumberThis object identifies the SFP DMI serial number.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.42
sfpDmiVendorNameThis object identifies the SFP DMI serial number.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.43
sfpDmiVendorPartNumberThis object identifies the SFP DMI serial number.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.44
xfpDmiAux1TypeThis object identifies the type of value that is being measured by the Auxillary 1 registers on the XFPro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.45
xfpDmiAux1StateThis object identifies current alarm status for the XFP Aux1 registersro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.46
xfpDmiRealTimeAux1This object identifies the XFP DMI real time values for the Aux1 registersro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.47
xfpDmiHighAux1WarnThis object identifies the XFP DMI high warning threshold for Aux1ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.48
xfpDmiHighAux1AlarmThis object identifies the XFP DMI alarm alarm threshold for Aux1ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.49
xfpDmiLowAux1WarnThis object identifies the XFP DMI low warning threshold for Aux1ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.50
xfpDmiLowAux1AlarmThis object identifies the XFP DMI low alarm threshold for Aux1ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.51
xfpDmiAux2TypeThis object identifies the type of value that is being measured by the Auxillary 1 registers on the XFPro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.52
xfpDmiAux2StateThis object identifies current alarm status for the XFP Aux2 registersro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.53
xfpDmiRealTimeAux2This object identifies the SFP DMI real time values for the Aux2 registersro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.54
xfpDmiHighAux2WarnThis object identifies the XFP DMI high warning threshold for Aux2ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.55
xfpDmiHighAux2AlarmThis object identifies the XFP DMI alarm alarm threshold for Aux2ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.56
xfpDmiLowAux2WarnThis object identifies the XFP DMI low warning threshold for Aux2ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.57
xfpDmiLowAux2AlarmThis object identifies the XFP DMI low alarm threshold for Aux2ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.58
xfpDmiMinBitRateThis object specifies the XFP minimum bit rate.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.59
xfpDmiMaxBitRateThis object specifies the XFP maximum bit rate.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.60
xfpDmiReachEBW50125This object specifies the link length that is supported by the fiber transceiver using extended bandwidth 50 micron core (125 micron jacket) multimode fiberro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.61
sfpDmiReachCopperThis object identifies the maximum length in meters that is supported by the SFP/XFP interface using copper cable.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.1.5.1.62
mcrAlarmsWarningsTableTable of outstanding alarms and warnings.
SEQUENCE OF McrAlarmsWarningsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.6
mcrAlarmsWarningsEntryEntries of the table, each relating to a separate alarm or warning.
McrAlarmsWarningsEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1
alarmWarnSequenceIndexThis object identifies the sequence in which the alarms or warnings were generated. Gaps in the sequence numbers are normal.
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.2
alarmWarnTypeThis object identifies the alert/Trap number associated with this alarm/warning.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.3
alarmWarnSeverityThis object identifies the severity level of the alarm/warning. Value will be one of the top three levels.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.4
alarmWarnFlagsThis object identifies the flags defining the alarm/warning. 0x00000002 - chassis type alert 0x00000004 - Power Supply Monitoring Unit type alert 0x00000008 - PSMU power supply type alert 0x00000010 - PSMU fan type alert 0x00000020 - Management module type alert 0x00000040 - Media converter module type alert 0x00000080 - Media converter module SFP module type alert.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.5
alarmWarnChassisNumThis object identifies the chassis number associated with this alarm/warning.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.6
alarmWarnDeviceNumThis object identifies the Hardware slot/bay location of the hardware associated with this alarm or warning. - 0 indicates alarm/warning occurred on the chassis backplane. - If AlarmWarnFlags indicates a power supply then this value the power supply bay number. - Otherwise it is the chassis slot number.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.7
alarmWarnTimeStampThis object identifies the time stamp of when the alarm/warning was reported. (in seconds since the Epoch, defined as 0:00:00 UTC on the morning of January 1, 1970), that the alert was reported on the MCR-MGT.)ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.8
alarmWarnMessageThis object identifies the alarm/warning message string which will contain any values of bound variables.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.9
alarmWarnPortNumThis object identifies the location of the media port associated with this alarm or warning.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.6.1.10
mcrMediaPortTableTable of general port status information.
SEQUENCE OF McrMediaPortEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.7
mcrMediaPortEntryEntries of the table, each relating to a separate media converter module port.
McrMediaPortEntry
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1
mediaPortSlotIndexSlot number for the media converter module containing this port.
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.2
mediaPortPortIndexPort number on media card. Valid values are 1 to the highest number of ports available on a media card. There are usually two ports
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.3
moduleModelThis object identifies the model name of the module containing this port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.4
portNameThis object identifies the name configured for this port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.5
portEnableThis object indicates whether the port has been enabled.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.6
portTypeThe type of port (copper, fiber, etc.) .ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.7
portLinkStatusThe port's current link status.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.8
portConnTypeThe port's connector typero
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.9
portAutoNegStateThe port's auto-negotiation statero
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.10
portSpeedIf the port auto-negotiation state is complete then this object indicates the ports current auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignoredro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.11
portDuplexIf port auto-negotiation state is complete then this object indicates the media converter module's current auto-negotiated duplex setting for this port. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.12
portPauseIf port auto-negotiation state is complete then this object indicates the media converter module's current auto-negotiated pause setting for this port. If auto-negotiation is not complete then the value returned should be ignored.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.13
portRemoteStatusThis port's Link Partner Remote Fault status or Far End Fault statusro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.14
portMediaTypeThe type of port (copper, fiber, etc.) .ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.15
portPhysicalProtocolThe physical networking protocol used by the port.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.1.7.1.16
mcrManagementGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2
mgtNetworkGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.1
systemGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1
systemStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.1
systemNameThe name of the system management module.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.2
systemDomainNameThe domain name of the management module.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.3
systemIpAddressThe management module's unique IPv4 network IP address. If you are using the management module in an IPv6 network, this field can be left blank.rw
IpAddress
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.4
systemSubnetBitsThe number of bits in the subnet mask. For example, a subnet mask of 255.255.0.0 has 16 subnet/prefix bits. Valid values are 0-32. The default is 0. When the value is 0, the correct value is determined based on the class of the IP Address.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.5
systemDHCPUpdateDNSIf enabled, the DNS system will be updated after the management module gets the IP address via DHCP.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.6
systemAutoObtainDNSIf on, the DNS server IP address will be obtained automatically automatically via DHCP.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.7
systemAutoObtainGWIf enabled, the default gateway IP address will be get automatically via DHCP.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.8
systemDomainPrefixThe domain prefix for primary Ethernet interface of the management module.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.9
systemTFTPRetryThe number of times the management module will attempt to transfer (using TFTP) a file to/from a host. Default is 5. A value of 0 (zero) means that the management module will not attempt a retry should TFTP fail.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.10
systemTFTPTimeOutThe time, in seconds, that the management module will wait for a successful transmit or receipt of TFTP packets before retrying a TFTP transfer. Default is 3 seconds.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.1.1.11
gatewayTableTable of configured gateway.
SEQUENCE OF GatewayEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2
gatewayEntryEntries of the table, each relating to a separate configured gateway.
GatewayEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1
gatewayIndexgatewayIndex
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.1
gatewayStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.2
gatewayHostYou can specify up to twenty hosts to act as gateways in your network. Each gateway host must be defined in the management module host table.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.3
gatewayTypeSpecify the type of gateway: Default-A gateway which provides general access beyond your local network. Host-A gateway reserved for accessing a specific host external to your local network. Network-A gateway reserved for accessing a specific network external to your local network.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.4
gatewayIpAddressWhen the gateway is a Host or Network gateway, you must specify the IP address of the target host machine/network.rw
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.5
gatewaySubnetBitsWhen the gateway is a Network gateway, you must specify the subnet/prefix bits for that network. If the IP address is IPv4, then the Subnet/Prefix Bits range is 0-32. If the IP address is IPv6, then the Subnet/Prefix Bits range is 0-128.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.6
gatewayInterfaceThe interface that the management module is going to use to access the Remote Host.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.7
hostTableThe hosts Group table.
SEQUENCE OF HostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.3
hostEntryAn entry in the host table, each relating to a separate host.
HostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1
hostIndexThe table entry number for this host.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.1
hostStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.2
hostNameThe host name used for this host entry. To delete an entry, blank out this field. If blank, this entry is currently unused.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.3
hostIpAddrThe host IP address used for this entry.rw
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.4
hostFqdnThe host full qualified domain name for the host entry. If blank, this entry is currently unused.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.5
dnsTableTable of DNS hosts
SEQUENCE OF DnsEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.4
dnsEntryEntries of the table, each relating to a separate DNS host.
DnsEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1
dnsIndexDNS host index
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.1
dnsStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.2
dnsIpAddressYou can specify the IP addresses for up to two DNS (Domain Name Servers) hosts in your network. The first DNS entry in the list is the primary DNS and the second DNS entry is the secondary server.rw
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.3
dnsActiveActivates/deactivates a DNS entry.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.4
dynamicDNSGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5
dynamicDNSStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.1
dynamicDNSEnable/disable dynamic DNS.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.2
dynamicDNSHostnameHost name.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.3
dynamicDNSUserNameUser name.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.4
dynamicDNSPasswordThis object identifies the dynamic DNS password. Reading of this object will always return a blank stringrw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.5
dynamicDNSSystemTypeSystem type.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.6
dynamicDNSWildCardSpecifies whether to add a alias such as * to your registered host name.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.7
dynamicDNSConnectionMethodSpecifies how the management module is going to connection to the DynDNS.org server.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.8
dynamicDNSSSLVerifyPeerCertificateEnable this option when you want the Validation Criteria to match the Peer Certificate for authentication to pass. If you enable this option, you need to download an SSL/TLS certificate authority (CA) list file to the management module. Any values that are entered in the validation criteria must match the peer certificate for an SSL connection; any fields left blank will not be validated against the peer certificate.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.9
dynamicDNSSSLCountryA two character country code; for example, US.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.10
dynamicDNSSSLStateProvUp to a 128 character entry for the state/province; for example, IL.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.11
dynamicDNSSSLLocalityUp to a 128 character entry for the location; for example, a city.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.12
dynamicDNSSSLOrganisationUp to a 64 character entry for the organization; for example, Accounting.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.13
dynamicDNSSSLOrganisationUnitUp to a 64 character entry for the unit in the organization; for example, Payroll.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.14
dynamicDNSSSLCommonNameUp to a 64 character entry for common name; for example, the host name or fully qualified domain name.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.15
dynamicDNSSSLEmailUp to a 64 character entry for an email address; for example, acct@anycompany.com.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.16
dynamicDNSStatusStringDynamic DNS statisticsro
OCTET STRING
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.17
dynamicDNSSSLCipherTableSSL Cipher.
SEQUENCE OF DynamicDNSSSLCipherEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18
dynamicDNSSSLCipherEntryAn entry in the dynamicDNSSSLCipherTable, each relating to a cipher entry.
DynamicDNSSSLCipherEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1
dynamicDNSSSLCipherPriorityThe cipher priority. 1- highest 5 - lowest.
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.1
dynamicDNSSSLCipherStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.2
dynamicDNSSSLCipherEncryptionSSL Encryption. None is not allowed for priority 1. Any will use the first encryption format that can be negotiated. The default is any.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.3
dynamicDNSSSLCipherKeySizeMinThe minimum key size value that will be used for the specified encryption type. The default is 40.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.4
dynamicDNSSSLCipherKeySizeMaxThe maximum key size value that will be used for the specified encryption type. The default is 256.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.5
dynamicDNSSSLCipherKeyExchangeThe type of key to exchange for the encryption format: Any-Any key exchange that is valid is used (this does not, however, include ADH keys). RSA-This is an RSA key exchange using an RSA key and certificate. EDHRSA-This is an EDH key exchange using an RSA key and certificate. EDHDSS-This is an EDH key exchange using a DSA key and certificate. ADH-This is an anonymous key exchange which does not require a private key or certificate. Choose this key if you do not want to authenticate the peer device, but you want the data encrypted on the SSL/TLS connection. The default is Any.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.6
dynamicDNSSSLCipherHMACSelect the key-hashing for message authentication method for your encryption type: Any, MD5, or SHA1. The default is Any.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.7
ipv6Group
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6
ipv6ServicesGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1
ipv6serviceStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.1
serviceAutoDiscoveryWhen on, the management module will send out a Router Solicitation message. If a Router Advertisement message is received, the management module will configure the IPv6 address(es) and configuration parameters based on the information contained in the advertisement. If no Router Advertisement message is received, the management module will attempt to connect to a DHCPv6 server to obtain IPv6 addresses and other configuration parameters. Default on.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.2
serviceDHCPv6When on, requests IPv6 address(es) and configuration information from the DHCPv6 server. Default off.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.3
serviceDHCPv6IPAddressesWhen on, the management module will accept IPv6 address(es) from the DHCPv6 server.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.4
serviceDHCPv6NetworkPrefixWhen on, the management module will accept the network prefix from the DHCPv6 server.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.5
serviceDHCPv6AutoObtainDNSIf on, the DNS server IP address will be obtained automatically automatically via DHCP.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.6
ipv6AddressTableIPv6 custom address table.
SEQUENCE OF Ipv6AddressEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2
ipv6AddressEntryIPv6 custom entry.
Ipv6AddressEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1
ipv6AddressIndexCustom IPv6 address index.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.1
ipv6AddressStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.2
ipv6AddressAddrEither enter a network prefix that the Device Server will use to derive an IPv6 address using the Device Server's MAC address (must turn ipv6AddressAuto1 on) or enter a specific IPv6 address.rw
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.3
ipv6AddressPrefixBitsThe IPv6 prefix bits of either the network or IPv6 address.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.4
ipv6AddressAutoWhen on, the management module will derive an IPv6 address from the entered network prefix and the management module's MAC address.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.5
ipv6AddressSendAdvertiseWhen on, the management module will include the IPv6 address in router advertisements.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.6
interfacev6StatsTableThe interface IPv6 Group table.
SEQUENCE OF Interfacev6StatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3
interfacev6StatsEntryAn entry in the interface IPv6 table
Interfacev6StatsEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1
interfacev6IndexThe IPv6 interface index.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.1
interfacev6NameThe IPv6 interface name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.2
interfacev6AddressThe IPv6 interface IP address.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.3
interfacev6PrefixBitsThe IPv6 interface Prefix bitsro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.4
interfacev6ScopeThe IPv6 interface scope.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.5
ipv6TunnelTableIPv6 tunnel table.
SEQUENCE OF Ipv6TunnelEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4
ipv6TunnelEntryIPv6 tunnel entry.
Ipv6TunnelEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1
ipv6TunnelIndexThe IPv6 tunnel index.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.1
ipv6TunnelStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.2
ipv6TunnelNameThe name of the IPv6 tunnel. Maximum 16 alphanumeric characters.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.3
ipv6TunnelModeThe method or protocol that is used to create the IPv6 tunnel. o Manual-When specified, the management module will manually create the IPv6 tunnel to the specified Remote Host through the specified Interface. o ip6to4-When specified, the MCR-MGT will broadcast to the multicast address 192.88.99.1 through the specified Interface. When the closest ip6to4 router responds, it will create the IPv6 tunnel, encapsulating and decapsulating IPv6 traffic sent to and from the management module. o Teredo-When specified, the Teredo protocol encapsulates the IPv6 packet as an IPv4 UDP message, allowing it to pass through most network address translator (NAT) boxes and create an IPv6 tunnel to the specified Remote Host (a Teredo server) through the specified Interface. Default is Manual.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.4
ipv6TunnelRemoteHostThe IPv4 host that can access the IPv6 network when the Mode is Manual. The Teredo server when the Mode is Teredo.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.5
mgtAccessGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2
mgtAcessServicesGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1
accessServicesStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.1
accessServicesSessInactTimeoutThe amount of time, in seconds, that the management session inactivity timer will run. When the timer expires, becuase no activity on the management session within the specified time, the management module will reset the management session. A value of 0 (zero), means that the inactivity timer will not expire (the session is open permanently, or until the user logs out).rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.2
accessServiceHTTPDTurn on/off the HTTPD Servicerw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.3
accessServiceHTTPSDTurn on/off the HTTPSD Servicerw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.4
accessServiceTelnetDTurn on/off the TelnetD Servicerw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.5
acessServiceSSHDTurn on/off the SSHD Servicerw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.6
acessServiceSnmpDTurn on/off the SnmpD Servicerw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.7
acessServiceSetIPTurn on/off the SetIP Servicerw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.8
acessIncomingPingsAllow incoming ping requests.rw
EnableDisableValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.1.9
webManagerGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2.2
webManagerStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.2.1
httpsPassphraseThis object identifies the HTTPS SSL certificate passphrase. Reading of this object will always return a blank stringrw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.2.2
sshServerGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3
sshServerStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.1
sshServerAuthRSAWhen a client SSH session requests RSA authentication, the management module's SSH server will authenticate the user via RSA.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.2
sshServerAuthDSAWhen a client SSH session requests DSA authentication, the management module's SSH server will authenticate the user via DSArw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.3
sshServerAuthKeyboardThe user types in a password for authentication.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.4
sshServerAuthPasswordThe user types in a password for authentication.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.5
sshServerCipher3DesThe management module SSH server's 3DES encryption is enable/disabled.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.6
sshServerCipherBlowfishThe management module SSH server's Blowfish encryption is enabled/disabled.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.7
sshServerCipherCipherAESThe management module SSH server's AES encryption is enabled/disabledrw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.8
sshServerCipherCASTThe management module SSH server's CAST encryption is enabled/disabledrw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.9
sshServerCipherArcfourThe management module SSH server's Arcfour encryption is enabled/disabled.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.10
sshServerVerboseDisplays debug messages on the terminal.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.11
sshServerCompressionRequests compression of all data. Compression is desirable on slow connections, but will only slow down things on fast networks.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.12
sshServerSSH1Enable/Disable SSH-1 on the server.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.3.13
snmpAgentGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4
snmpAgentStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.1
snmpContactThe name and contract information of the person who manages this SMNP node.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.2
snmpLocationThe physical location of the SNMP node.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.3
snmpCommunityTableTable of SNMP communities configured for the MCR-MGT agent
SEQUENCE OF SnmpCommunityEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4
snmpCommunityEntryEntries of the table, each relating to a separate SNMP community definition
SnmpCommunityEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1
snmpCommunityIndexThe MCR-MGT agent community index
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.1
snmpCommunityStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.2
snmpCommunityNameA name that will be sent to the management module from an SNMP manager. This name will define the permissions of the manager.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.3
snmpCommunityIpAddressThe IP address of the SNMP manager that will send requests to the management module. If the address is 0.0.0.0, any SNMP manager with the Community Name can access the management module.rw
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.4
snmpCommunityPermissionPermits the management module to respond to SNMP requests by: None -There is no response to requests from SNMP. Readonly -Responds only to Read requests from SNMP. Readwrite -Responds to both Read and Write requests from SNMP.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.5
snmpV3ReadOnlyUser
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5
snmpV3ReadOnlyStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.1
snmpV3ReadOnlyUserNameSNMP v3 read-only user name. This SNMP v3 user will have read-only S SNMP access permissions.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.2
snmpV3ReadOnlySecurityLevelSpecifies the SNMP v3 read-only user security level.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.3
snmpV3ReadOnlyAuthAlgorithmSpecifies the SNMP v3 read-only user authentication method.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.4
snmpV3ReadOnlyAuthPasswdSpecifies the SNMP v3 read-only user authentication password.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.5
snmpV3ReadOnlyPrivacyAlgorithmSpecifies the SNMP v3 read-only user privacy algorithm.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.6
snmpV3ReadOnlyPrivacyPasswdSpecifies the SNMP v3 read-only user privacy password.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.7
snmpV3ReadWriteUser
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6
snmpV3ReadWriteStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.1
snmpV3ReadWriteUserNameSpecifies the SNMP v3 read-write user name. This SNMP v3 user will have read-write SNMP access permissions.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.2
snmpV3ReadWriteSecurityLevelSpecifies the SNMP v3 read-write user security level.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.3
snmpV3ReadWriteAuthAlgorithmSpecifies the SNMP v3 read-write user authentication method.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.4
snmpV3ReadWriteAuthPasswdSpecifies the SNMP v3 read-write user authentication password.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.5
snmpV3ReadWritePrivacyAlgorithmSpecifies the SNMP v3 read-write user privacy algorithm.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.6
snmpV3ReadWritePrivacyPasswdSpecifies the SNMP v3 read-write user privacy password.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.7
authorizedHostGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5
authHostsStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.1
authHostOnlyDetermines whether only authorized hosts are allowed to access the management module. If set to yes then the management module will only respond to, and allow access to and from, the IP or MAC addresses of hosts configured in the authorized IP and MAC hosts tables.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.2
authIpHostTableThe hosts Group table.
SEQUENCE OF AuthIpHostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3
authIpHostEntryAn entry in the AuthIpHostTable, each relating to a IP host.
AuthIpHostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1
authHostIpIndexThe table entry number for this host.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.1
authHostIpStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.2
authHostIpAddrThe host IP address used for this entry.rw
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.3
authHostIpDescrThe host IP entry description.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.4
authMacHostTableThe hosts Group table.
SEQUENCE OF AuthMacHostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4
authMacHostEntryAn entry in the AuthIpHostTable, each relating to a host.
AuthMacHostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1
authHostMacIndexThe table entry number for this host.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.1
authHostMacStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.2
authHostMacAddrThe host MAC address used for this entry.rw
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.3
authHostMacDescrThe host MAC address entry description.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.4
mgtAlertGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.3
alertLocalEventGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.3.1
localEventLogStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.3.1.1
localEventLogEnabledDetermines whether alert events are logged to the internal local event log.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.3.1.2
localEventLogAlertLevelChoose the alert level that will trigger a local event being stored in the local event log. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a local event message.rw
AlertSeverityLevel
.1.3.6.1.4.1.1966.21.1.1.1.2.3.1.3
localEventLogClearWriting a yes(1) to this object will clear the local event log on the management module. Reading of this object will always return 0rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.3.1.4
alertSyslogGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.3.2
syslogStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.3.2.1
syslogEnabledDetermines whether syslog is enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.3.2.2
syslogSeverityLevelChoose the severity level that will trigger a syslog message: Emergency, Alert, Critical, Error, Warning, Notice, Info, Debug When you select a severity level, all the levels that appear above it in the list will also trigger a syslog message. For example, if you select Error, all Error, Critical, Alert, and Emergency events will generate a syslog message. NOTE: In addition to alert events, syslog message will also be generated for several non-alert system eventsrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.2.3
syslogPrimaryHostThe first preconfigured host that the management module will attempt to send system log messages to; messages will be displayed on the host's monitor.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.2.4
syslogSecondaryHostIf the management module cannot communicate with the primary host, then the management module will attempt to send system log messages to this preconfigured host; messages will be displayed on the host's monitor.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.2.5
alertSnmpTrapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3
snmpTrapStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.1
snmpTrapEnabledDetermines whether SNMP Traps are enabled.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.2
snmpTrapAlertLevelChoose the alert level that will trigger a SNMP trap message to be sent if SNMP traps is enabled. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a SNMP trap message.rw
AlertSeverityLevel
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.3
snmpTrapHostTableTable of SNMP Trap Hosts information.
SEQUENCE OF SnmpTrapHostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4
snmpTrapHostEntryEntries of the table, each relating to a separate SNMP trap host.
SnmpTrapHostEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1
snmpTrapHostIndexThis object identifies the SNMP trap host index.ro
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.1
snmpTrapHostStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.2
snmpTrapHostIpAddressDefines the hosts (by IP address) that will receive trap messages generated by the management module.rw
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.3
snmpTrapHostUdpPortDefines the UDP port number the SNMP trap host will listen on to receive trap messages generated by the management module.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.4
snmpTrapHostVersionDefines the SNMP version of the traps sent to this host. If snmpTrapV3 is selected then the SNMP trap v3 userrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.5
snmpTrapHostTypeIf set to snmpInform(1) the management module will send traps via an INFORM-PDU, expecting a response from the trap host, retransmitting if required. Otherwise it will send them via a TRAP-PDU or TRAP2-PDU. This object is ignored for for SNMP v1rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.6
snmpTrapHostCommunityAn arbitrary trap community name. This object is ignored for SNMP v3rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.7
snmpTrapHostEnableIf set to No, the management module will not use this table entry to send traps.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.8
snmpV3TrapUser
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5
snmpV3TrapUserStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.1
snmpV3TrapUserUserNameSNMP trap v3 user name. This user will be used for every SNMP trap host that is using snmpTrapHostVersion of snmpTrapV3(2)rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.2
snmpV3TrapUserSecurityLevelSNMP trap v3 user security level.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.3
snmpV3TrapUserAuthAlgorithmSNMP trap v3 user authentication method.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.4
snmpV3TrapUserAuthPasswdSNMP trap v3 user authentication password.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.5
snmpV3TrapUserPrivacyAlgorithmSNMP trap v3 user privacy algorithm.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.6
snmpV3TrapUserPrivacyPasswdSNMP trap v3 user privacy password.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.7
snmpTrapGlbHostTimeoutDefines the timeout in miliseconds between retries of sending the SNMP INFORM-PDU if no response is received for the trap host.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.6
snmpTapGlobHostRetriesDefines the number of retries to send the SNMP INFORM-PDU trap if no response is received from the trap host.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.7
snmpV3LocalEngineIDAn SNMPv3 engine ID used by the MCR-MGT for identification when sending SNMP v3 traps.ro
SnmpEngineID (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.8
snmpV3LocalEngineIDTextSuffixThis configured text is used to build the suffix of the SNMPv3 engine IDrw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.9
snmpTrapVarsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10
mgtAccessMethodDefines the management protocol used to access the management modulero
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.1
remoteMgtIpAddressDefines the remote IP address accessing the management modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.2
remoteTftpHostDefines the remote TFTP server IP address or host name performing the TFP file transferro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.3
remoteTftpFileNameDefines the remote TFTP file namero
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.4
networkIpAddressDefines the IP address assigned to the management modulero
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.5
mcrMediaPortNumThis object identifies the media converter module port number.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.6
mcrMediaPortDescrA description of the media port that consists of the user defined media port name, followed by the system name for the port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.7
eventSeverityLevelThe severity level of the event that generated this trap.ro
AlertSeverityLevel
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.8
xfpDmiRealTimeAuxThis object identifies the XFP DMI real time values for one of the auxillary register sets.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.9
xfpDmiHighAuxWarnThis object identifies the XFP DMI high warning threshold for one of the auxillary register sets.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.10
xfpDmiHighAuxAlarmThis object identifies the XFP DMI alarm alarm threshold for one of the auxillary register sets.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.11
xfpDmiLowAuxWarnThis object identifies the XFP DMI low warning threshold for one of the auxillary register sets.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.12
xfpDmiLowAuxAlarmThis object identifies the XFP DMI low alarm threshold for one of the auxillary register sets.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.13
mcrModuleSubTypeInsertedThis object identifies the module sub-type inserted in the slot.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.14
mcrMediaBackedupModuleSubTypeThis object identifies the module sub-type of the backup configuration.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.15
mcrMediaPortBandwidthThis object identifies the media converter module port's current bandwith in kbps.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.16
mcrMediaPortBandwidthThresholdThis object identifies the media converter module port's bandwith threshold in kbps.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.17
alertEmailGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4
emailStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.1
emailEnabledDetermines whether or not email notification is turned on. Default is Off.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.2
emailAlertLevelChoose the alert level that will trigger a email message to be sent if alert email is enabled. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a email message.rw
AlertSeverityLevel
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.3
emailToAn email address or list of email addresses that will receive the email notification.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.4
emailFromThis field can contain an email address that might identify the management module name or some other value.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.5
emailSMTPHostThe SMTP host (email server) that will process the email notification request. This can be either a host name defined in the management module host table or the SMTP host IP address.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.6
emailReplyThe email address to whom all replies to the email notification should go.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.7
emailSubjectA text string, which can contain spaces, that will display in the Subject field of the email notification.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.8
emailSMTPUsernameThe user name for the SMTP server, if the server requires authentication.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.9
emailSMTPPasswordThe password for the SMTP server, if the server requires authentication.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.10
emailSMTPEncryptionThe encryption method for the SMTP server.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.11
emailSMTPValidatePeerCertificateValidate peer SSL/TLS certificate, when SSL or TLS encryption is used.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.12
emailSMTPTcpPortThe TCP port used for communicating with the SMTP server. For no encryption or TLS encryption, use port 25. For SSL encryption, use port 465.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.13
emailSMTPDomainThe domain for NTLM authentication with the SMTP server, if applicable.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.3.4.14
mgtUsersGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.4
mgtUsersStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.1
mgtUsersByPassLoginEnabledIndicates whether by pass login is enabled. When enable users will be automatically login as admin user. The will not be prompted for a user ID or password when accessing the management module.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.2
mgtUsersPrimaryAuthMethodThe first authentication method that the management module attempts. Some type of authentication must be done by the management module.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.4.3
mgtUsersSecondaryAuthMethodIf the Primary Authentication Method fails, the next authentication method that the management module attempts. You can choose to use authentication methods in combination. For example, you can specify the Primary Authentication Method as Local and the Secondary Authentication Method as RADIUS. Therefore, some users can be defined in the Device Server (Local) others in RADIUS.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.4.4
mgtUsersAlwaysAttemptSecondIf enabled, the secondary authentication method will always be used.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.5
localUserAccountsTableTable of locally defined user information
SEQUENCE OF LocalUserAccountsEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.4.6
localUserAccountsEntryEntries of the table, each relating to separate user defined locally.
LocalUserAccountsEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1
userIndexThe table entry number for this user.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.1
userStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.2
userNameThe user name. To delete a user, set this field to blank. If blank, this entry is currently unused.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.3
userPasswordThe password for the local user.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.4
userLevelAdmin: Total access to the management module. More than one admin user account can exist, but we recommend that you only have one. operator: Full read only access to configuration and limited control commandsrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.5
localUsersStatusTableTable of locally defined user information
SEQUENCE OF LocalUsersStatusEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7
localUsersStatusEntryEntries of the table, each relating to separate user defined locally.
LocalUsersStatusEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1
userStatusIndexThe table entry number for this user status.
GenericTableIndex
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.1
userStatusNameThe user name. To delete a user, set this field to blank. If blank, this entry is currently unused.ro
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.2
userStatusMgtAccessTypeDefines the management protocol used to access the management module
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.3
userStatusRemoteIPAddressThis object specifies the remote IP address user management session.ro
Ipv4v6Address
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.4
userStatusStartTimeThis object identifies the date and time that the current user's management session started.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.5
userStatusLevelAdmin: Total access to the management module. More than one admin user account can exist, but we recommend that you only have one. operator: Full read only access to configuration and limited control commandsro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.6
radiusGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8
radiusStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.1
radiusPrimaryAuthHostPrimary Radius Authentication Hostrw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.2
radiusSecondaryAuthHostSecondary Radius Authentication Hostrw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.3
radiusAuthenticationPortThe port that the RADIUS host listens to for authentication requests. The default port is 1812.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.4
radiusAccountingRadius Accountingrw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.5
radiusPrimaryAcctHostName of the primary RADIUS authentication host.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.6
radiusSecondaryAcctHostName of the secondary RADIUS authentication host.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.7
radiusAccountingPortThe port that the RADIUS host listens to for accounting requests. The default port is 1813.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.8
radiusAcctAuthRadius Accounting Authenticatorrw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.9
radiusRetryLimitThe number of times the management module tries to connect to the RADIUS server before erroring out. Valid values are 0-255. The default is 5.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.10
radiusTimeoutThe time, in seconds, that the management module waits to receive a reply after sending out a request to a RADIUS accounting or authentication host. If no reply is received before the timeout period expires, the management module will retry the same host up to and including the number of retry attempts. Valid values are 1-255. The default is 3 seconds.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.11
radiusNasIdentifierThe NAS identifier name. To delete this , set this field to blank.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.12
radiusNasIpAddressWhen on, the NAS Identifier obtains ipv4 address automatically. Default is on.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.13
radiusNasSpecifyIpAddressSpecify the unique IPv4 address that NAS Identifier will userw
IpAddress
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.14
radiusNasIpv6AddressWhen on, the NAS Identifier obtains ipv6 address automatically. Default is on.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.15
radiusNasSpecifyIpv6AddressSpecify the unique IPv6 address that NAS Identifier will userw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.4.8.16
kerberosGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.4.9
kerberosStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.9.1
kerberosRealmThe Kerberos realm is the Kerberos host domain name, in upper-case letters.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.9.2
kerberosDomainThe name of a host running the KDC (Key Distribution Center) for the specified realm. The host name that you specify must either be defined in the management module's host Table before the last reboot or be resolved by DNS.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.9.3
kerberosPortThe port that the Kerberos server listens to for authentication requests. If no port is specified, the default port 88 is used.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.9.4
ldapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10
ldapStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.1
ldapHostThe name or IP address of the LDAP host. If you use a host name, that host must either have been defined in the management module's Host Table before the last reboot or be resolved by DNS. If you are using TLS, you must enter the same string you used to create the LDAP certificate.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.2
ldapPortThe port that the LDAP host listens to for authentication requests. The default port is 389.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.3
ldapBaseThe domain component (dc) that is the starting point for the search for user authentication.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.4
ldapEnableTLSEnables/disables the Transport Layer Security (TLS) with the LDAP host.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.5
ldapTLSPortSpecify the port number that LDAP will use for TLS. The default is port 636.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.6
ldapUIDLDAP user attribute. e.g. uid (OpenLDAP) sAMAccountName (Active Directory) The default is 'uid'.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.7
ldapPasswordEncryptionLDAP password encryption method.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.8
ldapClientAuthLDAP client authentication.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.9
ldapClientNameLDAP client name. Identifies the unit to the LDAP server, when client authentication is .rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.10
ldapClientAppendBaseAppend base to LDAP client name.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.11
ldapClientPasswordLDAP client password. Identifies the unit to the LDAP server, when client authentication is .rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.10.12
tacacsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11
tacacsStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.1
tacacsPrimaryHostThe primary TACACS+ host that is used for authentication.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.2
tacacsSecondaryHostThe secondary TACACS+ host that is used for authentication, should the primary TACACS+ host fail to respond.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.3
tacacsPortThe port number that TACACS+ listens to for authentication requests. The default port number is 49.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.4
tacacsAccountingEnable/Disable TACACS+ accountingrw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.5
tacacsAccountingPrimaryHostThe primary TACACS+ accounting host that is used for.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.6
tacacsAccountingSecondaryHostThe secondary TACACS+ accounting host that is used for , should the primary TACACS+ host fail to respond.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.7
tacacsAccountingPortThe port number that TACACS+ listens to for accounting requests. The default port number is 49.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.8
tacacsAuthorizationEnable/Disable TACACS+ authorizationrw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.9
tacacsAlternateServiceNamesEnable alternate service names for TACACS+.rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.11.10
securidGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.4.12
securidStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.12.1
securidMasterHostThe first SecurID server that is tried for user authentication.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.12.2
securidSlaveHostIf the first SecurID server does not respond to an authentication request, this is the next SecurID server that is tried for user authentication.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.12.3
securidPortThe port number that SecurID listens to for authentication requests. The default port number is 5500.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.4.12.4
securidTypeYou can specify either SDI or DES encryption for SecurID server communication. The default is SDI encryption.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.4.12.5
securidLegacyIf you are running SecurID 3.x or 4.x, you need to run in Legacy Mode. If you are running SecurID 5.x or above, do not select Legacy Mode.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.4.12.6
nisGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.4.13
nisStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.4.13.1
nisDomainThe NIS domain name.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.13.2
nisPrimaryHostThe primary NIS host that is used for authentication.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.13.3
nisSecondaryHostThe secondary NIS host that is used for authentication, should the primary NIS host fail to respond.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.4.13.4
mgtDateTimeGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.5
mgtDateTimeStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.5.1
systemDateThe system date. Format dd/mm/yyyy.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.5.2
systemTimeThe system time (local time). Format hh:mm:ss.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.5.3
systemDateTimeAndOffsetThis read only object identifies the current system date, time and GMT offset. The date and time will be displayed in the regional time format configured.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.5.4
timeZoneListEnableWhen the time zone list is enabled then the time zone being use is the one selected form the predefined list of time zones. If not enabled then the customTimeZoneGroup will define the time zone being usedrw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.5.5
selectionFromTimeZoneListThis object identifies the predefined time zone selected. This time zone will be used if timeZoneListEnable object is set to yes. configured.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.6
timeZoneAdjustForDSTThis object identifies if the time will be adjusted for DST (Daylight Savings Time) or not.rw
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.5.7
customTimeZoneGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8
customTimeZoneStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.1
timeZoneNameThe name of the time zone when using standard time.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.2
timeOffsetThe offset of summer time from standard time in minutes.rw
Integer32(-720..840)
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.3
timeSummerNameThe name of the time zone when using summer time.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.4
timeSummerOffsetThe offset of summer time from standard time in minutes.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.5
timeSummerModeYou can configure the summer time to take effect: None-No summer time change. Fixed-The summer time change goes into effect at the specified time every year. For example, April 15 at 1:00 pm. Recurring-The summer time changes goes into effect every year at same relative time. For example, on the third week in April on a Tuesday at 1:00 pm.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.6
timeSummerRecStartMonthThe recurring summer time start month.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.7
timeSummerRecStartWeekThe recurring summer time start week.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.8
timeSummerRecStartDayThe recurring summer time start day.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.9
timeSummerRecStartHourThe recurring summer time start hour.rw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.10
timeSummerRecStartMinThe recurring summer time start minuterw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.11
timeSummerRecEndMonthThe recurring summer time end month.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.12
timeSummerRecEndWeekThe recurring summer time end week.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.13
timeSummerRecEndDayThe recurring summer time end day.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.14
timeSummerRecEndHourThe recurring summer time end hourrw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.15
timeSummerRecEndMinThe recurring summer time end minuterw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.16
timeSummerFixStartMonthThe fixed summer time start monthrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.17
timeSummerFixStartDayThe fixed summer time start dayrw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.18
timeSummerFixStartHourThe fixed summer time start hourrw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.19
timeSummerFixStartMinuteThe fixed summer time start minuterw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.20
timeSummerFixEndMonthThe fixed summer time End monthrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.21
timeSummerFixEndDayThe fixed summer time End dayrw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.22
timeSummerFixEndHourThe fixed summer time End hourrw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.23
timeSummerFixEndMinuteThe fixed summer time End minuterw
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.8.24
networkTimeGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9
timeStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.1
timeSntpModeThe SNTP client mode. Valid modes are Disabled, Unicast, Multicast or Anycastrw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.2
timeSntpVersionThe sntp client version.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.3
timeSntpHost1The first remote SNTP host name that the device server communicates with.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.4
timeSntpHost2The second remote SNTP host name that the device server communicates with.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.5
sntpStatGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6
sntpStatAddressThe address of the remote SNMP host that updated the time.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.1
sntpStatLastUpdateThe time of the last update.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.2
sntpStatLeapIndicatorThe leap year indicator.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.3
sntpStatVersionThe SNTP version.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.4
sntpStatModeThe current SNTP modero
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.5
sntpStatStratumThe SNTP stratum.ro
Integer32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.6
sntpStatRefIdThe SNTP reference ID.ro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.7
sntpStatOffsetThe SNTP offsetro
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.8
timeSntpServerAuthenticationSpecifies whether to authenticate with the ntp time server.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.7
timeSntpKeyIDSpecifies the key ID to use for host 1 during server authentication.rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.8
timeSntpKeyID2Specifies the key ID to use for host 2 during server authentication.rw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.2.5.9.9
mgtFilesGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.6
mgtBootFilesGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.6.1
bootFileStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.6.1.1
fileFirmwareHostThe host name or IP address of the server that contains the firmware file. If you use a host name, it must exist in the management module's host table or be resolved by DNS.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.6.1.2
fileFirmwareNameThe path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the update software for the management module that will be loaded when the management module is rebooted.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.6.1.3
fileConfigurationHostThe host name or IP address of the server that contains the configuration file. If you use a host name, it must exist in the management module's host table or be resolved by DNS.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.6.1.4
fileConfigurationNameThe path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the new configuration file for the Device Server that will be loaded when the management module is rebooted.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.6.1.5
mgtfirmwareUpdatesGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2
firmwareUpdateStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.1
firmwareUpdateAutoEnable automatic updates of installed media converter modules from firmware bundle on management module..rw
OnOffValue
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.2
firmwareUpdateBundleVersionCm100This object identifies the bundled firmware version for CM-100 modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.3
firmwareUpdateBundleVersionCm110This object identifies the bundled firmware version for CM-110 modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.4
firmwareUpdateBundleVersionCm1000OrCm1000SfpThis object identifies the bundled firmware version for CM-1000 or CM-1000-SFP modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.5
firmwareUpdateBundleVersionCm1110This object identifies the bundled firmware version for CM-1110 modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.6
firmwareUpdateBundleVersionCm1110SfpThis object identifies the bundled firmware version for CM-1110-SFP modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.7
firmwareUpdateBundleVersionCm100mmThis object identifies the bundled firmware version for CM-100MM modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.8
firmwareUpdateBundleVersionCm1000mmThis object identifies the bundled firmware version for CM-1000MM modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.9
firmwareUpdateBundleVersionCm10gThis object identifies the bundled firmware version for CM-10G modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.1966.21.1.1.1.2.6.2.10
nettxfrTableTable of snmp file transfer sessions.
SEQUENCE OF NettxfrEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3
nettxfrEntryEntries of the table, each relating to a SNMP file transfer session.
NettxfrEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1
nettxfrSessionIDThis indicates if the net transfer is to be loaded to the management module or saved from the management module.
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.1
nettxfrStatusThis field indicates the status of the nettxfr process. A value of start(1) should be written to this field to start the nettxfr process with the specified parameters in the rest of this group.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.2
nettxfrDirectionThis indicates if the net transfer is to be loaded to the management module or saved from the management module.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.3
nettxfrFileTypeThis indicates the type of file to be transfered to/from the management module.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.4
nettxfrFileHostThe host name or IP address of the server that contains the file to be transfered to/from the management module.. If you use a host name, it must exist in the management module's host table or be resolved by DNS.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.5
nettxfrFileNameThe path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the file to be transfered to/from the management module.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.6
nettxfrMCSlotNumberSpecifies the slot number of the Media Converter Module to which the firmware will be transfered.rw
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.7
nettxfrUserNameSpecifies the user login name who owns the ssh public key that is to be transfered to the management module.rw
DisplayString
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.8
nettxfrSSHKeyTypeSpecifies the authentication method used by the ssh-server public key that is to be transfered to/from the management modulerw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.9
nettxfrSSLTypeSpecifies the type of SSL file to be transfered to the management module. These files are needed if you are using the secure version of the WebManager (HTTPS), or LDAP authentication with TLS.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.10
nettxfrSessionInUseSpecifies whether this net transfer session entry is in use. If a manager tries to write a 1 to this field and the session is already in use, then an error is returned.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.11
nettxfrTftpPortSpecifies a UDP port number for the TFTP host server. Default is 69.rw
Unsigned32
.1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.12
mgtAdminGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.7
adminFunctionPerform a specific function on the management module. If you want to save all the changes that have been submitted to the management module, you need to expand the adminGroup container folder and SET the adminFunction to 1 to write to FLASH. To make the configuration changes take effect, SET the adminFunction to 3 to reboot the management module.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.7.1
adminLastFunctionThe last function requestedro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.7.2
adminStatusThe status of the last function performed.ro
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.7.3
adminbootReasonThe reason(s) why the management module last rebooted.ro
Bits
.1.3.6.1.4.1.1966.21.1.1.1.2.7.4
adminDiagFileAvailableThis object indicates that a diagnostic file is available.ro
YesNoValue
.1.3.6.1.4.1.1966.21.1.1.1.2.7.5
mgtDisplayFormatGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.8
displayFormatStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.8.1
cfgTemperatureUnitsThis object identifies the units to display any internally measured temperature. The units can be Celsius or Fahrenheit.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.8.2
cfgSfpPowerUnitsThis object identifies the units to display any SFP DMI internally measured transmit/receive power. The units can be milliwatts (mW) or Decibel milliwatts (dBm).rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.8.3
cfgTimeFormatThis object identifies the format to display the time.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.8.4
cfgDateFormatThis object identifies the format to display date.rw
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.8.5
mgtChassisCfgGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.1.2.9
mgtChassisSlotPowerScheduleTableTable of power schedule configuration for chassis slots. (Not applicable to 2-slot chassis.)
SEQUENCE OF MgtChassisSlotPowerScheduleEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1
mgtChassisSlotPowerScheduleEntryEntries of the table, each relating to a separate slot in a chassis.
MgtChassisSlotPowerScheduleEntry
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1
powerSchedSlotIndexThis object identifies the chassis slot number.
SlotNumber
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.2
powerSchedDayOfWeekThis object identifies the day of the week.
Enumeration
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.3
powerSchedConifgStatusWhen you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded.rw
ContainerStatus
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.4
powerSchedOnHourThis object identifies the hour (0-23) of the day to schedule a power on of the chassis slotrw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.5
powerSchedOnMinuteThis object identifies the minute (0-59) of the hour to schedule a power on of the chassis slotrw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.6
powerSchedOffHourThis object identifies the hour (0-23) of the day to schedule a power off of the chassis slotrw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.7
powerSchedOffMinuteThis object identifies the minute (0-59) of the hour to schedule a power off of the chassis slotrw
INTEGER
.1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.8
mcrMGTMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.2
mcrMGTMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.2.1
mcrMGTMIBComplianceThe compliance statement for mcrMGT which implement the Perle Managed Media Converters MIB.
Unknown
.1.3.6.1.4.1.1966.21.1.1.2.1.1
mcrMGTMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.1966.21.1.1.2.2
mcrMGTMIBChassisGroupThe group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters chassis.
Unknown
.1.3.6.1.4.1.1966.21.1.1.2.2.1
mcrMGTMIBMediaGroupThe group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters media converter modules
Unknown
.1.3.6.1.4.1.1966.21.1.1.2.2.2
mcrMGTMIBMgtGroupThe group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters media converter modules
Unknown
.1.3.6.1.4.1.1966.21.1.1.2.2.3
mcrMGTMIBNotificationsGroupThe group of notifications (traps) which is implemented for the Perle Managed Media Converters.
Unknown
.1.3.6.1.4.1.1966.21.1.1.2.2.4