OPENGEAR-UPS-MIB
The OPENGEAR-UPS-MIB enables SNMP-based monitoring of OpenGear console server integrated UPS units, exposing critical power metrics such as battery status, input voltage, output load, and remaining runtime to facilitate remote power management and failover alerting.
Imported Objects
Objects
17 total| Object Name |
|---|
ogNetUpsMibOpengear UPS status MIB MODULE-IDENTITY .1.3.6.1.4.1.25049.10.16 |
ogNetUpsMibNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.25049.10.16.2 |
ognupsMibNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.25049.10.16.2.0 |
ognupsEventOccurredThe notification sent when a UPS status event occurs NOTIFICATION-TYPE .1.3.6.1.4.1.25049.10.16.2.0.200 |
ogNetUpsMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.25049.10.16.3 |
ogNetUpsMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.25049.10.16.3.1 |
ogNetUpsMibComplianceThe compliance statement for entities which implement the Opengear sensor MIB. Unknown .1.3.6.1.4.1.25049.10.16.3.1.1 |
ogNetUpsMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.25049.10.16.3.2 |
ogNetUpsMibGroupA collection of objects providing the sensor MIB capability. Unknown .1.3.6.1.4.1.25049.10.16.3.2.1 |
ognupsNotificationsGroupA collection of notification(s) for sensor system. Unknown .1.3.6.1.4.1.25049.10.16.3.2.2 |
ogNetUpsMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.25049.10.16.10 |
ognupsEvent OBJECT IDENTIFIER .1.3.6.1.4.1.25049.10.16.10.1 |
ognupsEventTableA table of serial signal events generated by this device. SEQUENCE OF OgNUpsEventEntry .1.3.6.1.4.1.25049.10.16.10.1.1 |
ognupsEventEntryA console connection event occuring at this device. Each entry is indexed by a message index. OgNUpsEventEntry .1.3.6.1.4.1.25049.10.16.10.1.1.1 |
ognupsEventIndexA monotonically increasing integer for the sole purpose of indexing messages. When it reaches the maximum value the agent flushes the table and wraps the value back to 1. Integer32 .1.3.6.1.4.1.25049.10.16.10.1.1.1.1 |
ognupsEventNameThe name of the UPS pertaining to the status eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25049.10.16.10.1.1.1.10 |
ognupsEventTypeThe type of status eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.25049.10.16.10.1.1.1.11 |
More MIBs from Opengear
Browse all OpengearMIBs →The OG-STATUSv2-MIB provides extended status and alerting capabilities for Opengear remote console and management appliances, specifically monitoring device health states, serial port session availability, and system event thresholds.
Standard SNMP MIB module defining data structures for OGTRAPv2-MIB.
The OG-OMTELEM-MIB facilitates SNMP-based telemetry collection for Opengear Operation Manager hardware, specifically exposing real-time operational metrics such as device temperature, fan status, power supply health, and serial port session activity. This module enables centralized monitoring of remote management server environmental conditions and connectivity states to support infrastructure availability and hardware fault detection.
The OG-STATUS-MIB provides SNMP access to legacy Opengear console server hardware status indicators and alert conditions, specifically monitoring device availability, port states, and system health events for remote management infrastructure.
Standard SNMP MIB module defining data structures for OGTRAP-MIB.
The OG-CM-STATUS-MIB enables SNMP-based monitoring of Opengear console server connection states, tracking active serial sessions, port availability, and link status for remote management infrastructure.