Home/Catalog/OPCD-SUPPORT-MIB-V2

OPCD-SUPPORT-MIB-V2

Opencode Support
Main OID:
opencode_systems.1.3.6.1.4.1.30374
56
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

56 total
Object Name
opencode_systemsOpencode Support
MODULE-IDENTITY
.1.3.6.1.4.1.30374
ocsupport
OBJECT IDENTIFIER
.1.3.6.1.4.1.30374.3
ocsupport_traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.30374.3.1
definitions
OBJECT IDENTIFIER
.1.3.6.1.4.1.30374.3.1.0
mcr_FANFan Failed!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.2
mcr_FAN_CanceledFan is OK!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.3
mcr_POWERPower Supply Failed!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.4
mcr_POWER_CanceledPower Supply is OK!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.5
mcr_TEMPERATURETemperature alarm!!Possible high temperature for zones on the server.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.6
mcr_TEMPERATURE_CanceledTemperature is in normal level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.7
mcr_HddFreeSpaceLow disk space!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.8
mcr_HddFreeSpace_CanceledCancel alarm for low disk space.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.9
mcr_MysqlServiceMysql Service is not accessible!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.10
mcr_MysqlService_CanceledMysql Service is accessible.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.11
mcr_DbFloatingIpUSSD DB Floating IP problem!! Possible floating ip down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.12
mcr_DbFloatingIp_CanceledFloating ip is accessible now.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.13
mcr_FailedEthNetwork(ethernet) interface Failure!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.14
mcr_FailedEth_CanceledFailed Network(ethernet) interface is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.15
mcr_UpsStatusProblem on ups system.Possible main power down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.16
mcr_UpsStatus_CanceledMain Power is up.Alarm is canceled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.17
mcr_SwitchConnectionNo connection to ethernet switch!! Possible network problem with switch.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.18
mcr_SwitchConnection_CanceledSwitch now is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.19
mcr_HddBayCheckHDD Drive Bay problem detected! Possible problem with failed disk or raid
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.20
mcr_HddBayCheck_CanceledHDD is ok.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.21
ss7LinkDownSS7 link down
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.22
ss7LinkDown_CanceledSS7 link/s is/are up now.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.23
ussdb_RunSlaveUssdbrowser was started on slave Node!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.24
ussdb_RunSlave_CanceledUssdbrowser is running in noramal mode now.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.25
ussdb_HeartbeatDownHeartbeat is down!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.26
ussdb_HeartbeatDown_CanceledHeartbeat is down!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.27
ussdb_ConnectionDownUSSD Browser floating IP is down on the Master Node!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.28
ussdb_ConnectionDown_CanceledUSSD Browser floating IP is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.29
ussdb_SwitchedUssdbrowser Master has been switched!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.30
ussdb_Switched_CanceledUssdbrowser Master has been switched - canceled!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.31
ussdb_AppDownUssdbrowser Application down!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.32
ussdb_AppDown_CanceledUssdbrowser Application is up-Canceled
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.33
ussdb_DbDownDatabase Down!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.34
ussdb_DbDown_CanceledDatabase is up!
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.35
mcr_DBbackupDB backup problem
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.36
mcr_DBbackup_CanceledDB backup problem alarm is canceled
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.37
voicetrunksVoice trunk Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.38
voicetrunks_CanceledVoice trunk Failure canceled
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.39
nodedownNode seems to be down
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.40
nodedown_CanceledNode seems to be up now.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.41
testTest alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.42
test_CanceledTest alarm canceled
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.43
mcr_MSA2012_ProblemMSA 2012 storage problem detected. Possible problems: 1.Hard disk failed. 2.Power supply failed. 3.Network connection failed. 4.Controller failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.44
mcr_MSA2012_Problem_CanceledMSA 2012 storage problem detected - canceled
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.45
mcr_TEMPERATURE_CUSTTemperature alarm!!Possible high temperature for zones on the server. To check the status execute commands hplog -t
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.46
mcr_TEMPERATURE_CUST_CanceledTemperature is in normal level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.47
mcr_DBReplicationReplication problem detected.Check status with command 'show slave status' from mysql cli for more information.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.48
mcr_DBReplication_CanceledReplication is working without problems.
NOTIFICATION-TYPE
.1.3.6.1.4.1.30374.3.1.0.49
vars
OBJECT IDENTIFIER
.1.3.6.1.4.1.30374.3.1.1
mcr_HostString containing hostname of fault node.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.30374.3.1.1.1
mcr_SeverityAlarm severity.ro
Enumeration
.1.3.6.1.4.1.30374.3.1.1.2
mcr_TextString containing text of the alarm.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.30374.3.1.1.3
OPCD-SUPPORT-MIB-V2 - SNMP MIB Reference | MIBs Explorer