OPCD-SUPPORT-MIB-V2
Opencode Support
Main OID:
opencode_systems.1.3.6.1.4.1.30374
56
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
56 total| Object Name |
|---|
opencode_systemsOpencode Support MODULE-IDENTITY .1.3.6.1.4.1.30374 |
ocsupport OBJECT IDENTIFIER .1.3.6.1.4.1.30374.3 |
ocsupport_traps OBJECT IDENTIFIER .1.3.6.1.4.1.30374.3.1 |
definitions OBJECT IDENTIFIER .1.3.6.1.4.1.30374.3.1.0 |
mcr_FANFan Failed!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.2 |
mcr_FAN_CanceledFan is OK!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.3 |
mcr_POWERPower Supply Failed!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.4 |
mcr_POWER_CanceledPower Supply is OK!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.5 |
mcr_TEMPERATURETemperature alarm!!Possible high temperature for zones on the server. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.6 |
mcr_TEMPERATURE_CanceledTemperature is in normal level. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.7 |
mcr_HddFreeSpaceLow disk space!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.8 |
mcr_HddFreeSpace_CanceledCancel alarm for low disk space. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.9 |
mcr_MysqlServiceMysql Service is not accessible!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.10 |
mcr_MysqlService_CanceledMysql Service is accessible. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.11 |
mcr_DbFloatingIpUSSD DB Floating IP problem!! Possible floating ip down. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.12 |
mcr_DbFloatingIp_CanceledFloating ip is accessible now. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.13 |
mcr_FailedEthNetwork(ethernet) interface Failure!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.14 |
mcr_FailedEth_CanceledFailed Network(ethernet) interface is up. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.15 |
mcr_UpsStatusProblem on ups system.Possible main power down. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.16 |
mcr_UpsStatus_CanceledMain Power is up.Alarm is canceled. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.17 |
mcr_SwitchConnectionNo connection to ethernet switch!! Possible network problem with switch. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.18 |
mcr_SwitchConnection_CanceledSwitch now is up. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.19 |
mcr_HddBayCheckHDD Drive Bay problem detected! Possible problem with failed disk or raid NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.20 |
mcr_HddBayCheck_CanceledHDD is ok. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.21 |
ss7LinkDownSS7 link down NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.22 |
ss7LinkDown_CanceledSS7 link/s is/are up now. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.23 |
ussdb_RunSlaveUssdbrowser was started on slave Node! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.24 |
ussdb_RunSlave_CanceledUssdbrowser is running in noramal mode now. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.25 |
ussdb_HeartbeatDownHeartbeat is down! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.26 |
ussdb_HeartbeatDown_CanceledHeartbeat is down! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.27 |
ussdb_ConnectionDownUSSD Browser floating IP is down on the Master Node! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.28 |
ussdb_ConnectionDown_CanceledUSSD Browser floating IP is up. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.29 |
ussdb_SwitchedUssdbrowser Master has been switched!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.30 |
ussdb_Switched_CanceledUssdbrowser Master has been switched - canceled!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.31 |
ussdb_AppDownUssdbrowser Application down!! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.32 |
ussdb_AppDown_CanceledUssdbrowser Application is up-Canceled NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.33 |
ussdb_DbDownDatabase Down! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.34 |
ussdb_DbDown_CanceledDatabase is up! NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.35 |
mcr_DBbackupDB backup problem NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.36 |
mcr_DBbackup_CanceledDB backup problem alarm is canceled NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.37 |
voicetrunksVoice trunk Failure NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.38 |
voicetrunks_CanceledVoice trunk Failure canceled NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.39 |
nodedownNode seems to be down NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.40 |
nodedown_CanceledNode seems to be up now. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.41 |
testTest alarm NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.42 |
test_CanceledTest alarm canceled NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.43 |
mcr_MSA2012_ProblemMSA 2012 storage problem detected. Possible problems: 1.Hard disk failed. 2.Power supply failed. 3.Network connection failed. 4.Controller failed. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.44 |
mcr_MSA2012_Problem_CanceledMSA 2012 storage problem detected - canceled NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.45 |
mcr_TEMPERATURE_CUSTTemperature alarm!!Possible high temperature for zones on the server. To check the status execute commands hplog -t NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.46 |
mcr_TEMPERATURE_CUST_CanceledTemperature is in normal level. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.47 |
mcr_DBReplicationReplication problem detected.Check status with command 'show slave status' from mysql cli for more information. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.48 |
mcr_DBReplication_CanceledReplication is working without problems. NOTIFICATION-TYPE .1.3.6.1.4.1.30374.3.1.0.49 |
vars OBJECT IDENTIFIER .1.3.6.1.4.1.30374.3.1.1 |
mcr_HostString containing hostname of fault node.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30374.3.1.1.1 |
mcr_SeverityAlarm severity.ro Enumeration .1.3.6.1.4.1.30374.3.1.1.2 |
mcr_TextString containing text of the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30374.3.1.1.3 |