Home/Catalog/ONS15501-MIB

ONS15501-MIB

AI MIB Summary

The ONS15501-MIB module enables SNMP-based monitoring and management of Cisco ONS 15501 optical amplifier hardware, specifically tracking optical power levels, gain status, alarm conditions, and component health metrics.

The MIB definitions for ONS-15501 Optical Amplifier.
100
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

100 total
Object Name
synchronous
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869
synEmbLx
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11
ons15501MIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1869.11.11
ons15501Sys
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.1
ons15501SysDevFlash1ImageGives the name of the software programmed on flash bank one.ro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.1
ons15501SysDevFlash2ImageGives the name of the software programmed on flash bank two.ro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.2
ons15501SysDevFlash3ImageGives the name of the software programmed on flash bank three.ro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.3
ons15501SysSwDownloadUsed to control the image download to the flash banks. NOTE: Read on this attribute returns the last t/ftp command, without login/password. For s/w release 4.0 and above, the value read back includes the Kilo-Bytes downloaded for last download command. It is the size of file downloaded (in KB), if the download has completed. If a download is in progress this value would correspond to Kilo-Bytes successfully downloaded so far. For set the string syntax is one of the following a. abort - Aborts the current download b. ftp:<svr-IP>:<login>:<pass>:<path>:<fName>:<flash#>[:passive] - Download image using ftp c. tftp:<srvr-IP>:<fName>:<flashNo> - Download image using tftp where <svr-IP> - is t/ftp server name <login> - is login to be used for ftp (default anonymous) <pass> - password for the login name for ftp (default - no passwd - passwd is empty string) <path> - path to be given on ftp prompt for cd (default - skip cd command ) <fName> - name of the file to be downloaded and burnt to the flash - NO DEFAULTS - because the filename is used as distinguishing versions there are no defaults for this command. For TFTP Path information is part of the filename <flash#> - which flash has to be burnt [1|2|3] NOTE: Burn to active bank fails passive - if `passive` is specified, ftp is done using passive mode (provided for FTP download across firewall). NOTE: None of the fields should contain ':' within them, as it is used as field separator.rw
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.4
ons15501SysDevActiveImageShow currently active image's bank number. This may be different from ons15501SysConfiguredActiveImage, if a. The image on ons15501SysConfiguredActiveImage did not boot properly. b. User chose another bank during bootup, using the serial console port.ro
Gauge
.1.3.6.1.4.1.1869.11.11.1.5
ons15501SysDeviceManagerListA ',' separated list of managers that will receive the Traps. If a specific host should receive the traps sent from this unit, it should be added to the list using CLI. Up to 16 managers can be present in this list.ro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.6
ons15501SysSwDownloadStatusDenotes the FTP/TFTP status. Please refer to the description of Ons15501ImageDnLoadStatus for a list of supported valuesro
Ons15501ImageDnLoadStatus -- Rsyntax INTEGER { -- notInitiated(1), -- inProgress(2), -- failedUnknownErr(3), -- failedFileNotFound(4), -- failedAccessDenied(5), -- failedTimedOut(6), -- completedSuccessfully(7), -- failedInDownload(8), -- failedTimeoutInDownload(9), -- failedToConnectToServer(10), -- failedWhileWritingToFlash(11), -- failedIllegalOperation(12), -- failedFileExists(13), -- failedUnknownTransferId(14), -- failedUnknownUser(15) -- }
.1.3.6.1.4.1.1869.11.11.1.7
ons15501SysConfiguredImageSet/Show configured value for flash-bank number to be used on reboot. A set on this attribute will result in a reboot of the system. To restart the system, write back the same value as the one read from it (or from ons15501SysDevActiveImage).rw
Gauge
.1.3.6.1.4.1.1869.11.11.1.8
ons15501CLEICodeThis attribute represents the CLEI (Common Language Equipment Identifier) code for the ONS15501.ro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.9
ons15501PrimaryNTPThe IP address for the primary NTP server.rw
IpAddress
.1.3.6.1.4.1.1869.11.11.1.10
ons15501SecondaryNTPThe IP address for the secondary NTP server.rw
IpAddress
.1.3.6.1.4.1.1869.11.11.1.11
ons15501NTPAdminStatusThe configured administrative status for NTP.rw
Ons15501AdminStatus -- Rsyntax INTEGER { -- disabled(1), -- enabled(2) -- }
.1.3.6.1.4.1.1869.11.11.1.12
ons15501NTPOperationalStatusThe operational status for NTP.ro
Ons15501NTPStatus -- Rsyntax INTEGER { -- disabled(1), -- bothServersBad(2), -- usingPrimary(3), -- usingSecondary(4), -- unknown(5) -- }
.1.3.6.1.4.1.1869.11.11.1.13
ons15501ActiveSoftwareVerThis attribute provides the active software version. This will be same as the entPhysicalSoftwareRev for the entry corresponding to the chassis.ro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.14
ons15501LastConfigChangeTimeThe value of sysUpTime when last configuration change was done. NMS may use this information to synchronize if some configuration has changed on the unit.ro
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.1869.11.11.1.15
ons15501InRemoteInfoUpdateTimeThis attribute gives the time-stamp when one or more of ons15501InRemoteChassisName, ons15501InRemotePortName, or ons15501InRemoteAgentIpAddr was changed. NMS may use this information to find the latest information if data from remote unit does not match that of this unit.ro
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.1869.11.11.1.16
ons15501InRemoteChassisNameManager initialized string value to identify the chassis associated with remote connection for optical input. ons15501InRemoteChassisName would be a ZERO length string if the input link is disabled. To disable the input link details set ons15501InRemoteChassisName to ZERO length string and ons15501InRemoteAgentIpAddr to 0.0.0.0.rw
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.17
ons15501InRemotePortNameManager initialized string value to identify the the port (on remote chassis) associated with remote connection for optical input. ons15501InRemotePortName would be a ZERO length string if the input link is disabled. To disable the input link details set ons15501InRemoteChassisName to ZERO length string and ons15501InRemoteAgentIpAddr to 0.0.0.0.rw
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.18
ons15501InRemoteAgentIpAddrManager initialized string value to identify the network address to be used to reach the SNMP agent entity containing information about the port and chassis providing optical input. ons15501InRemoteAgentIpAddr would be a 0.0.0.0 if the input link is disabled. To disable the input link entry set ons15501InRemoteChassisName to ZERO length string and ons15501InRemoteAgentIpAddr to 0.0.0.0.rw
IpAddress
.1.3.6.1.4.1.1869.11.11.1.19
ons15501OutRemoteInfoUpdateTimeThis attribute gives the time-stamp when one or more of ons15501OutRemoteChassisName, ons15501OutRemotePortName, or ons15501OutRemoteAgentIpAddr was changed. NMS may use this information to find the latest information if data from remote unit does not match that of this unit.ro
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.1869.11.11.1.20
ons15501OutRemoteChassisNameManager initialized string value to identify the chassis associated with remote connection for optical output. ons15501OutRemoteChassisName would be a ZERO length string if the output link is disabled. To disable the output link details set ons15501OutRemoteChassisName to ZERO length string and ons15501OutRemoteAgentIpAddr to 0.0.0.0.rw
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.21
ons15501OutRemotePortNameManager initialized string value to identify the the port (on remote chassis) associated with remote connection for optical output. ons15501OutRemotePortName would be a ZERO length string if the output link is disabled. To disable the output link details set ons15501OutRemoteChassisName to ZERO length string and ons15501OutRemoteAgentIpAddr to 0.0.0.0.rw
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.22
ons15501OutRemoteAgentIpAddrManager initialized string value to identify the network address to be used to reach the SNMP agent entity containing information about the port and chassis using optical output. ons15501OutRemoteAgentIpAddr would be a 0.0.0.0 if the output link is disabled. To disable the output link entry set ons15501OutRemoteChassisName to ZERO length string and ons15501OutRemoteAgentIpAddr to 0.0.0.0.rw
IpAddress
.1.3.6.1.4.1.1869.11.11.1.23
ons15501SysAlarmStatusProvides the highest severity alarm currently active.ro
Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- }
.1.3.6.1.4.1.1869.11.11.1.24
ons15501SysDateAndTimeThe date and time of the System. The write will not succeed if the administrative state for NTP (ons15501NTPAdminStatus) is 'enabled'. Setting this attribute will autmatically change values for ons15501TrapLogEntryDateAndTime and ons15501ActAlarmDateAndTime.rw
DateAndTime -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.1.25
ons15501Attr
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.2
ons15501InputOpticalPowerThe optical power being fed into the Amplifier.ro
Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dBm
.1.3.6.1.4.1.1869.11.11.2.1
ons15501InputOpticalPowerMeanMean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputOpticalPowerTrigger) an alarm is generated. The alarm is cleared when the input optical power is back within 90% of trigger from the mean.rw
Ons15501TenthdB(-100..0) -- Rsyntax INTEGER(-100..0) -- Units -- dBm
.1.3.6.1.4.1.1869.11.11.2.2
ons15501InputOpticalPowerTriggerTrigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the input optical power falls back within 90% of the trigger value from the mean. Please also refer to ons15501InputOpticalPowerMean above.rw
Ons15501TenthdB
.1.3.6.1.4.1.1869.11.11.2.3
ons15501OutputOpticalPowerThe measured value for raw optical power being generated at the output of the Amplifier.ro
Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dBm
.1.3.6.1.4.1.1869.11.11.2.4
ons15501OutputSignalPowerThe optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm +> -29 dBm -10 dBm Input Optical Powerro
Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dBm
.1.3.6.1.4.1.1869.11.11.2.5
ons15501OutputSignalPowerMeanMean value for output optical power. If the output signal power falls below (or goes above) the mean value by more than trigger (see ons15501OutputSignalPowerTrigger) an alarm is generated. The alarm is cleared when the output optical power is back within 90% of trigger from the mean.rw
Ons15501TenthdB(-60..0) -- Rsyntax INTEGER(-60..0) -- Units -- dBm
.1.3.6.1.4.1.1869.11.11.2.6
ons15501OutputSignalPowerTriggerTrigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the output signal power falls back within 90% of the trigger value from the mean. Please also refer to ons15501OutputSignalPowerMean above.rw
Ons15501TenthdB
.1.3.6.1.4.1.1869.11.11.2.7
ons15501ConfigOpticalGainThe configured value for power gain.rw
Ons15501TenthdB
.1.3.6.1.4.1.1869.11.11.2.8
ons15501OpticalPowerGainThe measured value for power gain. This value does not include the amplification noise that is significant for low input signals.ro
Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dB
.1.3.6.1.4.1.1869.11.11.2.9
ons15501GainTriggerThe gain deviation allowed from the configured gain before an alarm is asserted. The alarm is not cleared, until measured gain(ons15501OpticalPowerGain) is back within 90% of ons15501GainTrigger from configured gain (ons15501ConfigOpticalGain).rw
Ons15501TenthdB
.1.3.6.1.4.1.1869.11.11.2.10
ons15501PowerSupply1LevelThe voltage fed through power supply 1. The value of the attribute is 10 times the the value in volts.ro
Ons15501TenthVolt -- Rsyntax INTEGER(-1000..0) -- Units -- volts
.1.3.6.1.4.1.1869.11.11.2.11
ons15501PowerSupply2LevelThe voltage fed through power supply 2. The value of the attribute is 10 times the the value in volts.ro
Ons15501TenthVolt -- Rsyntax INTEGER(-1000..0) -- Units -- volts
.1.3.6.1.4.1.1869.11.11.2.12
ons15501LaserStatusGives the status of the laser pumps.ro
Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- }
.1.3.6.1.4.1.1869.11.11.2.13
ons15501DevAmbTempThe ambient temperature for the device.ro
Ons15501TenthCentigrade -- Rsyntax INTEGER(-500..1000) -- Units -- degrees C
.1.3.6.1.4.1.1869.11.11.2.14
ons15501DevAmbTempMeanMean value for temperature. If the temperature falls below (or goes above) the mean value by more than trigger level (see ons15501DevAmbTempTrigger) an alarm is generated. The alarm is cleared when the temperature is back within 90% of trigger value, from the mean.rw
Ons15501TenthCentigrade
.1.3.6.1.4.1.1869.11.11.2.15
ons15501DevAmbTempTriggerPlease refer to ons15501DevAmbTempMean above. Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the temperature falls back within 90% of the value.rw
Ons15501TenthCentigrade
.1.3.6.1.4.1.1869.11.11.2.16
ons15501PowerSupply1StatusGives the status of power supply one.ro
Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- }
.1.3.6.1.4.1.1869.11.11.2.17
ons15501PowerSupply2StatusGives the status of power supply two.ro
Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- }
.1.3.6.1.4.1.1869.11.11.2.18
ons15501Alarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.3
ons15501LastTrapIndexThe value of ons15501TrapLogEntryIndex, used while logging the most recent trap. Goes back to 1, after reaching the max value. The trap log table is a circular list with the most recent entry at index given by this attribute. On restart of the unit, the value is reset to 1.ro
Gauge
.1.3.6.1.4.1.1869.11.11.3.1
ons15501TrapLogTableTable for last N traps (N = 100 in most cases). Please refer to ons15501LastTrapIndex for details on how this table is organized.
SEQUENCE OF Ons15501TrapLogEntry
.1.3.6.1.4.1.1869.11.11.3.2
ons15501TrapLogEntryEntry for a trap
Ons15501TrapLogEntry
.1.3.6.1.4.1.1869.11.11.3.2.1
ons15501TrapLogEntryIndexindex field for this entry. Actual range at run time is ons15501TrapCounter to ons15501TrapCounter - N + 1 or 1 (whichever is higher)
Gauge
.1.3.6.1.4.1.1869.11.11.3.2.1.1
ons15501TrapLogEntryTrapTypeThe type of trap. See the definition of Ons15501TrapTypeEnumeration for possible values.ro
Ons15501TrapTypeEnumeration -- Rsyntax INTEGER { -- unacceptableAmbientTemperature(1), -- unacceptableElectricalPower(2), -- inputSignalPowerTooLow(3), -- unacceptableOutputSignalPower(4), -- embeddedControllerCommFailure(5), -- softwareUpgradeInitiated(6), -- softwareUpgradeFailed(7), -- softwareUpgradeCompleted(8), -- softwareRebootInitiated(9), -- softwareRolledBack(10), -- configurationChanged(11), -- unacceptableGain(12), -- laserPumpBad(13), -- eEPROMBad(14), -- unknown(32767) -- }
.1.3.6.1.4.1.1869.11.11.3.2.1.2
ons15501TrapLogEntryDirectionWhether the trap is being asserted or cleared. Please note that some traps don't have a direction. (e.g. configuration changed).ro
Ons15501TrapDirectionEnumeration -- Rsyntax INTEGER { -- dontCare(1), -- asserted(2), -- cleared(3) -- }
.1.3.6.1.4.1.1869.11.11.3.2.1.3
ons15501TrapLogEntryTimeStampThe value of sysUpTime when the entry was placed in the log.ro
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.1869.11.11.3.2.1.4
ons15501TrapLogEntryDateAndTimeThe local date and time at which the entry was placed in the log.ro
DateAndTime -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.3.2.1.5
ons15501TrapLogEntryPhyIndexProvides entPhysicalIndex value for the physical entity corresponding to the trap entry.ro
PhysicalIndex -- Rsyntax INTEGER
.1.3.6.1.4.1.1869.11.11.3.2.1.6
ons15501TrapLogEntrySeverityProvides the severity level corresponding to this trap entry.ro
Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- }
.1.3.6.1.4.1.1869.11.11.3.2.1.7
ons15501ActiveAlarmTableTable for currently active alarm conditions. This table is effectively the list of traps that have been asserted but not cleared.
SEQUENCE OF Ons15501ActiveAlarmEntry
.1.3.6.1.4.1.1869.11.11.3.3
ons15501ActiveAlarmEntryEntry for an active alarm condition. For each alarm condition present on the equipment, there would be an entry in the table.
Ons15501ActiveAlarmEntry
.1.3.6.1.4.1.1869.11.11.3.3.1
ons15501ActAlarmTypeIndex field for ons15501ActiveAlarmTable. Presence of an entry implies that the specific alarm type is active on the unit.
Ons15501TrapTypeEnumeration -- Rsyntax INTEGER { -- unacceptableAmbientTemperature(1), -- unacceptableElectricalPower(2), -- inputSignalPowerTooLow(3), -- unacceptableOutputSignalPower(4), -- embeddedControllerCommFailure(5), -- softwareUpgradeInitiated(6), -- softwareUpgradeFailed(7), -- softwareUpgradeCompleted(8), -- softwareRebootInitiated(9), -- softwareRolledBack(10), -- configurationChanged(11), -- unacceptableGain(12), -- laserPumpBad(13), -- eEPROMBad(14), -- unknown(32767) -- }
.1.3.6.1.4.1.1869.11.11.3.3.1.1
ons15501ActAlarmTimeStampThe time since when the alarm is active.ro
TimeStamp -- Rsyntax TimeTicks
.1.3.6.1.4.1.1869.11.11.3.3.1.2
ons15501ActAlarmDateAndTimeThe local date and time since when the alarm is activero
DateAndTime -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.3.3.1.3
ons15501ActAlarmPhyIndexProvides entPhysicalIndex value for the physical entity corresponding to the alarm entry.ro
PhysicalIndex -- Rsyntax INTEGER
.1.3.6.1.4.1.1869.11.11.3.3.1.4
ons15501ActAlarmSeverityProvides the severity level corresponding to this alarm entry.ro
Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- }
.1.3.6.1.4.1.1869.11.11.3.3.1.5
ons15501TrapDescriptionTableTable for mapping the Ons15501TrapTypeEnumeration values to their textual information.
SEQUENCE OF Ons15501TrapDescriptionEntry
.1.3.6.1.4.1.1869.11.11.3.4
ons15501TrapDescriptionEntryEntry for textual information about traps.
Ons15501TrapDescriptionEntry
.1.3.6.1.4.1.1869.11.11.3.4.1
ons15501TrapTypeValueIndex field for this entry.
Ons15501TrapTypeEnumeration -- Rsyntax INTEGER { -- unacceptableAmbientTemperature(1), -- unacceptableElectricalPower(2), -- inputSignalPowerTooLow(3), -- unacceptableOutputSignalPower(4), -- embeddedControllerCommFailure(5), -- softwareUpgradeInitiated(6), -- softwareUpgradeFailed(7), -- softwareUpgradeCompleted(8), -- softwareRebootInitiated(9), -- softwareRolledBack(10), -- configurationChanged(11), -- unacceptableGain(12), -- laserPumpBad(13), -- eEPROMBad(14), -- unknown(32767) -- }
.1.3.6.1.4.1.1869.11.11.3.4.1.1
ons15501TrapDescriptionThe textual information corresponding to the ons15501TrapTypeValue.ro
DisplayString -- Rsyntax OCTET STRING
.1.3.6.1.4.1.1869.11.11.3.4.1.2
ons15501TrapSeverityProvides the default severity level corresponding to the ons15501TrapTypeValue.ro
Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- }
.1.3.6.1.4.1.1869.11.11.3.4.1.3
ons15501Notification
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.4
ons15501NotificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.4.0
ons15501GenericNotificationTrapThis notification is generated whenever a bitmap change is observed on any of the monitored equipment, or when a change has to be notified.
TRAP-TYPE
.1.3.6.1.4.1.1869.11.11.4.0.1
ons15501OIDs
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5
ons15501OIDSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.1
ons15501OIDEntity
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.2
ons15501OIDChasiss
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.2.1
ons15501OIDInPort
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.2.2
ons15501OIDOutPort
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.2.3
ons15501OIDPowerSupply
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.2.4
ons15501OIDChassisAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.2.5
ons15501OIDPowerSupplyAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.2.6
ons15501OIDSystemAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.5.3
ons15501MIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6
ons15501MIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.1
ons15501FinalCompliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.1.1
ons15501Rel4Compliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.1.2
ons15501MIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2
ons15501SysInfoGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.1
ons15501TrapLogGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.2
ons15501ActiveAlarmGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.3
ons15501TrapDescriptionGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.4
ons15501FinalAttrGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.5
ons15501FinalNotificationsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.6
ons15501CoreAttrGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.7
ons15501PowerSupplyStatusGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.8
ons15501PowerSupplyLevelGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.9
ons15501SysInfoGroup2
OBJECT IDENTIFIER
.1.3.6.1.4.1.1869.11.11.6.2.10
ONS15501-MIB - SNMP MIB Reference | MIBs Explorer