ONS15501-MIB
AI MIB Summary
The ONS15501-MIB module enables SNMP-based monitoring and management of Cisco ONS 15501 optical amplifier hardware, specifically tracking optical power levels, gain status, alarm conditions, and component health metrics.
The MIB definitions for ONS-15501 Optical Amplifier.
100
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
100 total| Object Name |
|---|
synchronous OBJECT IDENTIFIER .1.3.6.1.4.1.1869 |
synEmbLx OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11 |
ons15501MIB OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1869.11.11 |
ons15501Sys OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.1 |
ons15501SysDevFlash1ImageGives the name of the software programmed on flash
bank one.ro DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.1 |
ons15501SysDevFlash2ImageGives the name of the software programmed on flash
bank two.ro DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.2 |
ons15501SysDevFlash3ImageGives the name of the software programmed on flash
bank three.ro DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.3 |
ons15501SysSwDownloadUsed to control the image download to the flash banks.
NOTE: Read on this attribute returns the last t/ftp command,
without login/password.
For s/w release 4.0 and above, the value read back
includes the Kilo-Bytes downloaded for last download
command.
It is the size of file downloaded (in KB), if the
download has completed. If a download is in progress
this value would correspond to Kilo-Bytes successfully
downloaded so far.
For set the string syntax is one of the following
a. abort
- Aborts the current download
b. ftp:<svr-IP>:<login>:<pass>:<path>:<fName>:<flash#>[:passive]
- Download image using ftp
c. tftp:<srvr-IP>:<fName>:<flashNo>
- Download image using tftp
where
<svr-IP> - is t/ftp server name
<login> - is login to be used for ftp (default anonymous)
<pass> - password for the login name for ftp
(default - no passwd - passwd is empty string)
<path> - path to be given on ftp prompt for cd
(default - skip cd command )
<fName> - name of the file to be downloaded and burnt
to the flash - NO DEFAULTS - because the
filename is used as distinguishing versions
there are no defaults for this command.
For TFTP Path information is part of the filename
<flash#> - which flash has to be burnt [1|2|3]
NOTE: Burn to active bank fails
passive - if `passive` is specified, ftp is done using
passive mode (provided for FTP download across
firewall).
NOTE: None of the fields should contain ':' within them, as
it is used as field separator.rw DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.4 |
ons15501SysDevActiveImageShow currently active image's bank number.
This may be different from ons15501SysConfiguredActiveImage,
if
a. The image on ons15501SysConfiguredActiveImage did not
boot properly.
b. User chose another bank during bootup, using the
serial console port.ro Gauge .1.3.6.1.4.1.1869.11.11.1.5 |
ons15501SysDeviceManagerListA ',' separated list of managers that will receive the
Traps.
If a specific host should receive the traps sent from this
unit, it should be added to the list using CLI.
Up to 16 managers can be present in this list.ro DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.6 |
ons15501SysSwDownloadStatusDenotes the FTP/TFTP status. Please refer to the description
of Ons15501ImageDnLoadStatus for a list of supported valuesro Ons15501ImageDnLoadStatus -- Rsyntax INTEGER { -- notInitiated(1), -- inProgress(2), -- failedUnknownErr(3), -- failedFileNotFound(4), -- failedAccessDenied(5), -- failedTimedOut(6), -- completedSuccessfully(7), -- failedInDownload(8), -- failedTimeoutInDownload(9), -- failedToConnectToServer(10), -- failedWhileWritingToFlash(11), -- failedIllegalOperation(12), -- failedFileExists(13), -- failedUnknownTransferId(14), -- failedUnknownUser(15) -- } .1.3.6.1.4.1.1869.11.11.1.7 |
ons15501SysConfiguredImageSet/Show configured value for flash-bank number to be used
on reboot.
A set on this attribute will result in a reboot of the system.
To restart the system, write back the same value as the
one read from it (or from ons15501SysDevActiveImage).rw Gauge .1.3.6.1.4.1.1869.11.11.1.8 |
ons15501CLEICodeThis attribute represents the CLEI (Common Language
Equipment Identifier) code for the ONS15501.ro DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.9 |
ons15501PrimaryNTPThe IP address for the primary NTP server.rw IpAddress .1.3.6.1.4.1.1869.11.11.1.10 |
ons15501SecondaryNTPThe IP address for the secondary NTP server.rw IpAddress .1.3.6.1.4.1.1869.11.11.1.11 |
ons15501NTPAdminStatusThe configured administrative status for NTP.rw Ons15501AdminStatus -- Rsyntax INTEGER { -- disabled(1), -- enabled(2) -- } .1.3.6.1.4.1.1869.11.11.1.12 |
ons15501NTPOperationalStatusThe operational status for NTP.ro Ons15501NTPStatus -- Rsyntax INTEGER { -- disabled(1), -- bothServersBad(2), -- usingPrimary(3), -- usingSecondary(4), -- unknown(5) -- } .1.3.6.1.4.1.1869.11.11.1.13 |
ons15501ActiveSoftwareVerThis attribute provides the active software version.
This will be same as the entPhysicalSoftwareRev for
the entry corresponding to the chassis.ro DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.14 |
ons15501LastConfigChangeTimeThe value of sysUpTime when last configuration
change was done.
NMS may use this information to synchronize if
some configuration has changed on the unit.ro TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.1869.11.11.1.15 |
ons15501InRemoteInfoUpdateTimeThis attribute gives the time-stamp when one or more of
ons15501InRemoteChassisName, ons15501InRemotePortName,
or ons15501InRemoteAgentIpAddr was changed.
NMS may use this information to find the latest
information if data from remote unit does not match
that of this unit.ro TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.1869.11.11.1.16 |
ons15501InRemoteChassisNameManager initialized string value to identify the
chassis associated with remote connection for
optical input.
ons15501InRemoteChassisName would be a ZERO length
string if the input link is disabled.
To disable the input link details set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0.rw DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.17 |
ons15501InRemotePortNameManager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical input.
ons15501InRemotePortName would be a ZERO length
string if the input link is disabled.
To disable the input link details set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0.rw DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.18 |
ons15501InRemoteAgentIpAddrManager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
providing optical input.
ons15501InRemoteAgentIpAddr would be a 0.0.0.0
if the input link is disabled.
To disable the input link entry set
ons15501InRemoteChassisName to ZERO length string
and ons15501InRemoteAgentIpAddr to 0.0.0.0.rw IpAddress .1.3.6.1.4.1.1869.11.11.1.19 |
ons15501OutRemoteInfoUpdateTimeThis attribute gives the time-stamp when one or more of
ons15501OutRemoteChassisName, ons15501OutRemotePortName,
or ons15501OutRemoteAgentIpAddr was changed.
NMS may use this information to find the latest
information if data from remote unit does not match
that of this unit.ro TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.1869.11.11.1.20 |
ons15501OutRemoteChassisNameManager initialized string value to identify the
chassis associated with remote connection for
optical output.
ons15501OutRemoteChassisName would be a ZERO length
string if the output link is disabled.
To disable the output link details set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0.rw DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.21 |
ons15501OutRemotePortNameManager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical output.
ons15501OutRemotePortName would be a ZERO length
string if the output link is disabled.
To disable the output link details set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0.rw DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.22 |
ons15501OutRemoteAgentIpAddrManager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
using optical output.
ons15501OutRemoteAgentIpAddr would be a 0.0.0.0
if the output link is disabled.
To disable the output link entry set
ons15501OutRemoteChassisName to ZERO length string
and ons15501OutRemoteAgentIpAddr to 0.0.0.0.rw IpAddress .1.3.6.1.4.1.1869.11.11.1.23 |
ons15501SysAlarmStatusProvides the highest severity alarm currently active.ro Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- } .1.3.6.1.4.1.1869.11.11.1.24 |
ons15501SysDateAndTimeThe date and time of the System.
The write will not succeed if the administrative
state for NTP (ons15501NTPAdminStatus)
is 'enabled'.
Setting this attribute will autmatically change
values for ons15501TrapLogEntryDateAndTime and
ons15501ActAlarmDateAndTime.rw DateAndTime -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.1.25 |
ons15501Attr OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.2 |
ons15501InputOpticalPowerThe optical power being fed into the Amplifier.ro Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dBm .1.3.6.1.4.1.1869.11.11.2.1 |
ons15501InputOpticalPowerMeanMean value for input optical power.
If the input optical power falls below
the mean value by more than trigger
(see ons15501InputOpticalPowerTrigger) an alarm
is generated. The alarm is cleared when the
input optical power is back within 90% of trigger
from the mean.rw Ons15501TenthdB(-100..0) -- Rsyntax INTEGER(-100..0) -- Units -- dBm .1.3.6.1.4.1.1869.11.11.2.2 |
ons15501InputOpticalPowerTriggerTrigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
input optical power falls back within 90% of the
trigger value from the mean. Please also refer
to ons15501InputOpticalPowerMean above.rw Ons15501TenthdB .1.3.6.1.4.1.1869.11.11.2.3 |
ons15501OutputOpticalPowerThe measured value for raw optical power being
generated at the output of the Amplifier.ro Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dBm .1.3.6.1.4.1.1869.11.11.2.4 |
ons15501OutputSignalPowerThe optical signal power at the output of the Amplifier.
The value of this attribute triggers the alarm, based on
mean value and trigger as defined by
ons15501OutputSignalPowerMean and
ons15501OutputSignalPowerTrigger.
This value is internally calculated using the following
formula.
ons15501OutputSignalPower = ons15501OpticalPowerGain +
ons15501InputOpticalPower
At very low ons15501InputOpticalPower (below -16 dBm),
the ons15501OutputSignalPower has significant difference
from ons15501OutputOpticalPower while at higher input
power (ons15501InputOpticalPower) they are closer.
Following graph captures the difference (for a 17 dBm
EDFA)
(dashes '-'/'_' denote optical output power
while dots '.' denote signal output power)
^
| .-
| .-
| .-
+5 dBm | .-
| .-
Optical | _.-
power / | _ -.
Signal |_ _ - .
power | .
| .
| .
-17 dBm +>
-29 dBm -10 dBm
Input Optical Powerro Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dBm .1.3.6.1.4.1.1869.11.11.2.5 |
ons15501OutputSignalPowerMeanMean value for output optical power.
If the output signal power falls below (or goes
above) the mean value by more than trigger
(see ons15501OutputSignalPowerTrigger) an alarm
is generated. The alarm is cleared when the
output optical power is back within 90% of trigger
from the mean.rw Ons15501TenthdB(-60..0) -- Rsyntax INTEGER(-60..0) -- Units -- dBm .1.3.6.1.4.1.1869.11.11.2.6 |
ons15501OutputSignalPowerTriggerTrigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
output signal power falls back within 90% of the
trigger value from the mean. Please also refer
to ons15501OutputSignalPowerMean above.rw Ons15501TenthdB .1.3.6.1.4.1.1869.11.11.2.7 |
ons15501ConfigOpticalGainThe configured value for power gain.rw Ons15501TenthdB .1.3.6.1.4.1.1869.11.11.2.8 |
ons15501OpticalPowerGainThe measured value for power gain.
This value does not include the amplification
noise that is significant for low input signals.ro Ons15501TenthdB -- Rsyntax INTEGER(-1000..500) -- Units -- dB .1.3.6.1.4.1.1869.11.11.2.9 |
ons15501GainTriggerThe gain deviation allowed from the configured gain
before an alarm is asserted. The alarm is not cleared,
until measured gain(ons15501OpticalPowerGain) is back
within 90% of ons15501GainTrigger from configured gain
(ons15501ConfigOpticalGain).rw Ons15501TenthdB .1.3.6.1.4.1.1869.11.11.2.10 |
ons15501PowerSupply1LevelThe voltage fed through power supply 1.
The value of the attribute is 10 times the
the value in volts.ro Ons15501TenthVolt -- Rsyntax INTEGER(-1000..0) -- Units -- volts .1.3.6.1.4.1.1869.11.11.2.11 |
ons15501PowerSupply2LevelThe voltage fed through power supply 2.
The value of the attribute is 10 times the
the value in volts.ro Ons15501TenthVolt -- Rsyntax INTEGER(-1000..0) -- Units -- volts .1.3.6.1.4.1.1869.11.11.2.12 |
ons15501LaserStatusGives the status of the laser pumps.ro Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- } .1.3.6.1.4.1.1869.11.11.2.13 |
ons15501DevAmbTempThe ambient temperature for the device.ro Ons15501TenthCentigrade -- Rsyntax INTEGER(-500..1000) -- Units -- degrees C .1.3.6.1.4.1.1869.11.11.2.14 |
ons15501DevAmbTempMeanMean value for temperature.
If the temperature falls below (or goes above) the
mean value by more than trigger level (see
ons15501DevAmbTempTrigger) an alarm is generated.
The alarm is cleared when the temperature is back
within 90% of trigger value, from the mean.rw Ons15501TenthCentigrade .1.3.6.1.4.1.1869.11.11.2.15 |
ons15501DevAmbTempTriggerPlease refer to ons15501DevAmbTempMean above.
Trigger defines the max deviation allowed from the
mean, without an alarm being generated. Once an
alarm is generated, it is not cleared until the
temperature falls back within 90% of the value.rw Ons15501TenthCentigrade .1.3.6.1.4.1.1869.11.11.2.16 |
ons15501PowerSupply1StatusGives the status of power supply one.ro Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- } .1.3.6.1.4.1.1869.11.11.2.17 |
ons15501PowerSupply2StatusGives the status of power supply two.ro Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- } .1.3.6.1.4.1.1869.11.11.2.18 |
ons15501Alarms OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.3 |
ons15501LastTrapIndexThe value of ons15501TrapLogEntryIndex, used while logging
the most recent trap. Goes back to 1, after reaching
the max value.
The trap log table is a circular list with the most
recent entry at index given by this attribute.
On restart of the unit, the value is reset to 1.ro Gauge .1.3.6.1.4.1.1869.11.11.3.1 |
ons15501TrapLogTableTable for last N traps (N = 100 in most cases).
Please refer to ons15501LastTrapIndex for
details on how this table is organized. SEQUENCE OF Ons15501TrapLogEntry .1.3.6.1.4.1.1869.11.11.3.2 |
ons15501TrapLogEntryEntry for a trap Ons15501TrapLogEntry .1.3.6.1.4.1.1869.11.11.3.2.1 |
ons15501TrapLogEntryIndexindex field for this entry. Actual range at
run time is ons15501TrapCounter to
ons15501TrapCounter - N + 1 or 1
(whichever is higher) Gauge .1.3.6.1.4.1.1869.11.11.3.2.1.1 |
ons15501TrapLogEntryTrapTypeThe type of trap. See the definition
of Ons15501TrapTypeEnumeration for possible values.ro Ons15501TrapTypeEnumeration -- Rsyntax INTEGER { -- unacceptableAmbientTemperature(1), -- unacceptableElectricalPower(2), -- inputSignalPowerTooLow(3), -- unacceptableOutputSignalPower(4), -- embeddedControllerCommFailure(5), -- softwareUpgradeInitiated(6), -- softwareUpgradeFailed(7), -- softwareUpgradeCompleted(8), -- softwareRebootInitiated(9), -- softwareRolledBack(10), -- configurationChanged(11), -- unacceptableGain(12), -- laserPumpBad(13), -- eEPROMBad(14), -- unknown(32767) -- } .1.3.6.1.4.1.1869.11.11.3.2.1.2 |
ons15501TrapLogEntryDirectionWhether the trap is being asserted or cleared.
Please note that some traps don't have a direction.
(e.g. configuration changed).ro Ons15501TrapDirectionEnumeration -- Rsyntax INTEGER { -- dontCare(1), -- asserted(2), -- cleared(3) -- } .1.3.6.1.4.1.1869.11.11.3.2.1.3 |
ons15501TrapLogEntryTimeStampThe value of sysUpTime when the entry was placed in
the log.ro TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.1869.11.11.3.2.1.4 |
ons15501TrapLogEntryDateAndTimeThe local date and time at which the entry was placed in
the log.ro DateAndTime -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.3.2.1.5 |
ons15501TrapLogEntryPhyIndexProvides entPhysicalIndex value for the physical entity
corresponding to the trap entry.ro PhysicalIndex -- Rsyntax INTEGER .1.3.6.1.4.1.1869.11.11.3.2.1.6 |
ons15501TrapLogEntrySeverityProvides the severity level corresponding to this
trap entry.ro Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- } .1.3.6.1.4.1.1869.11.11.3.2.1.7 |
ons15501ActiveAlarmTableTable for currently active alarm conditions.
This table is effectively the list of traps
that have been asserted but not cleared. SEQUENCE OF Ons15501ActiveAlarmEntry .1.3.6.1.4.1.1869.11.11.3.3 |
ons15501ActiveAlarmEntryEntry for an active alarm condition.
For each alarm condition present on the
equipment, there would be an entry in
the table. Ons15501ActiveAlarmEntry .1.3.6.1.4.1.1869.11.11.3.3.1 |
ons15501ActAlarmTypeIndex field for ons15501ActiveAlarmTable.
Presence of an entry implies that the specific
alarm type is active on the unit. Ons15501TrapTypeEnumeration -- Rsyntax INTEGER { -- unacceptableAmbientTemperature(1), -- unacceptableElectricalPower(2), -- inputSignalPowerTooLow(3), -- unacceptableOutputSignalPower(4), -- embeddedControllerCommFailure(5), -- softwareUpgradeInitiated(6), -- softwareUpgradeFailed(7), -- softwareUpgradeCompleted(8), -- softwareRebootInitiated(9), -- softwareRolledBack(10), -- configurationChanged(11), -- unacceptableGain(12), -- laserPumpBad(13), -- eEPROMBad(14), -- unknown(32767) -- } .1.3.6.1.4.1.1869.11.11.3.3.1.1 |
ons15501ActAlarmTimeStampThe time since when the alarm is active.ro TimeStamp -- Rsyntax TimeTicks .1.3.6.1.4.1.1869.11.11.3.3.1.2 |
ons15501ActAlarmDateAndTimeThe local date and time since when the alarm is activero DateAndTime -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.3.3.1.3 |
ons15501ActAlarmPhyIndexProvides entPhysicalIndex value for the physical entity
corresponding to the alarm entry.ro PhysicalIndex -- Rsyntax INTEGER .1.3.6.1.4.1.1869.11.11.3.3.1.4 |
ons15501ActAlarmSeverityProvides the severity level corresponding to this
alarm entry.ro Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- } .1.3.6.1.4.1.1869.11.11.3.3.1.5 |
ons15501TrapDescriptionTableTable for mapping the Ons15501TrapTypeEnumeration
values to their textual information. SEQUENCE OF Ons15501TrapDescriptionEntry .1.3.6.1.4.1.1869.11.11.3.4 |
ons15501TrapDescriptionEntryEntry for textual information about traps. Ons15501TrapDescriptionEntry .1.3.6.1.4.1.1869.11.11.3.4.1 |
ons15501TrapTypeValueIndex field for this entry. Ons15501TrapTypeEnumeration -- Rsyntax INTEGER { -- unacceptableAmbientTemperature(1), -- unacceptableElectricalPower(2), -- inputSignalPowerTooLow(3), -- unacceptableOutputSignalPower(4), -- embeddedControllerCommFailure(5), -- softwareUpgradeInitiated(6), -- softwareUpgradeFailed(7), -- softwareUpgradeCompleted(8), -- softwareRebootInitiated(9), -- softwareRolledBack(10), -- configurationChanged(11), -- unacceptableGain(12), -- laserPumpBad(13), -- eEPROMBad(14), -- unknown(32767) -- } .1.3.6.1.4.1.1869.11.11.3.4.1.1 |
ons15501TrapDescriptionThe textual information corresponding to the
ons15501TrapTypeValue.ro DisplayString -- Rsyntax OCTET STRING .1.3.6.1.4.1.1869.11.11.3.4.1.2 |
ons15501TrapSeverityProvides the default severity level corresponding
to the ons15501TrapTypeValue.ro Ons15501AlarmStatus -- Rsyntax INTEGER { -- critical(1), -- major(2), -- minor(3), -- info(4), -- noAlarm(5) -- } .1.3.6.1.4.1.1869.11.11.3.4.1.3 |
ons15501Notification OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.4 |
ons15501NotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.4.0 |
ons15501GenericNotificationTrapThis notification is generated whenever a bitmap change is
observed on any of the monitored equipment, or when a change
has to be notified. TRAP-TYPE .1.3.6.1.4.1.1869.11.11.4.0.1 |
ons15501OIDs OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5 |
ons15501OIDSystem OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.1 |
ons15501OIDEntity OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.2 |
ons15501OIDChasiss OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.2.1 |
ons15501OIDInPort OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.2.2 |
ons15501OIDOutPort OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.2.3 |
ons15501OIDPowerSupply OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.2.4 |
ons15501OIDChassisAC OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.2.5 |
ons15501OIDPowerSupplyAC OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.2.6 |
ons15501OIDSystemAC OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.5.3 |
ons15501MIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6 |
ons15501MIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.1 |
ons15501FinalCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.1.1 |
ons15501Rel4Compliance OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.1.2 |
ons15501MIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2 |
ons15501SysInfoGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.1 |
ons15501TrapLogGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.2 |
ons15501ActiveAlarmGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.3 |
ons15501TrapDescriptionGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.4 |
ons15501FinalAttrGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.5 |
ons15501FinalNotificationsGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.6 |
ons15501CoreAttrGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.7 |
ons15501PowerSupplyStatusGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.8 |
ons15501PowerSupplyLevelGroup OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.9 |
ons15501SysInfoGroup2 OBJECT IDENTIFIER .1.3.6.1.4.1.1869.11.11.6.2.10 |