ONEACCESS-UPS-MIB

AI MIB Summary

ONEACCESS-UPS-MIB enables SNMP-based monitoring and management of OneAccess Uninterruptible Power Supply units, exposing critical operational metrics such as battery status, input/output voltage levels, load percentage, and remaining runtime.

The MIB module to describe Uninterruptible Power Supplies.
Main OID:
oacUpsMIB.1.3.6.1.4.1.13191.10.3.4.1225
11
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

11 total
Object Name
oacUpsMIBThe MIB module to describe Uninterruptible Power Supplies.
MODULE-IDENTITY
.1.3.6.1.4.1.13191.10.3.4.1225
oacUpsMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.13191.10.3.4.1225.1
oacUpsBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.13191.10.3.4.1225.1.1
oacUpsBatteryStatusThe indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).ro
Enumeration
.1.3.6.1.4.1.13191.10.3.4.1225.1.1.1
oacUpsAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.13191.10.3.4.1225.1.2
oacUpsAlarmsPresentThe present number of active alarm conditions.ro
Gauge32
.1.3.6.1.4.1.13191.10.3.4.1225.1.2.1
oacUpsAlarmDescrA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.ro
AutonomousType (SNMPv2-TC)
.1.3.6.1.4.1.13191.10.3.4.1225.1.2.2
oacUpsAlarmTimeThe value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.13191.10.3.4.1225.1.2.3
oacUpsTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.13191.10.3.4.1225.2
oacUpsTrapAlarmEntryAddedThis trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for upsAlarmOnBattery and upsAlarmTestInProgress.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13191.10.3.4.1225.2.0
oacUpsTrapAlarmEntryRemovedThis trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for upsAlarmTestInProgress.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13191.10.3.4.1225.2.1