ONEACCESS-OAM-MIB
AI MIB Summary
The ONEACCESS-OAM-MIB module facilitates the monitoring and management of OneAccess broadband aggregation gateways and DSLAMs via SNMP, specifically enabling the retrieval of Operations, Administration, and Maintenance (OAM) status indicators such as port states, link connectivity, and remote loopback diagnostics.
Contact updated
Main OID:
oacOamMIBModule.1.3.6.1.4.1.13191.1.100.673
54
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
54 total| Object Name |
|---|
oacOamMIBModuleContact updated MODULE-IDENTITY .1.3.6.1.4.1.13191.1.100.673 |
oacAtmOamStatObjects OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.2.2.1 |
oacAtmOamStatSwitch OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.2.2.1.1 |
oacAtmOamSwitchMaxConnectionsMaximum number of authorised OAM configured connectionsro Unsigned32 .1.3.6.1.4.1.13191.10.3.2.2.1.1.1 |
oacAtmOamSwitchSegLoopbackEnable segment loopback on this switchro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.1.2 |
oacAtmOamSwitchEndLoopbackEnable end to end loopback on this switchro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.1.3 |
oacAtmOamSwitchAisRdiEnableEnable Remote Defect Indication OAM cell generation
if an Alarm Indication Signal OAM cell is received, or if a
defect is detected on the switchro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.1.4 |
oacAtmOamSwitchSegmentContinuityCheckEnableEnable Segment Loss of Continuity cells defect on the pvc.
Enable generation of segment Continuity Check cells on the switch.ro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.1.5 |
oacAtmOamSwitchEndContinuityCheckEnableEnable End to End Loss of Continuity cells defect on the pvc.
Enable generation of End to End Continuity Check cells on the switch.ro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.1.6 |
oacAtmOamSwitchOamCellsReceivedNumber of received OAM cells on the switchro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.1.7 |
oacAtmOamSwitchOamCellsTransmittedNumber of transmitted OAM cells on the switchro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.1.8 |
oacAtmOamSwitchCurrentConnectionsCurrent number of OAM configured connectionsro Unsigned32 .1.3.6.1.4.1.13191.10.3.2.2.1.1.9 |
oacAtmOamVclTableAn index into the table oacAtmOamVclTable SEQUENCE OF OacAtmOamVclEntry .1.3.6.1.4.1.13191.10.3.2.2.1.2 |
oacAtmOamVclEntryAn index into the table oacAtmOamVclTable OacAtmOamVclEntry .1.3.6.1.4.1.13191.10.3.2.2.1.2.1 |
oacAtmOamVclPvcManageEnable OAM for Pvc managementro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.1 |
oacAtmOamVclSegmentLoopbackEnable segment loopback on this virtual channelro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.2 |
oacAtmOamVclEndLoopbackEnable end to end loopback on this virtual channelro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.3 |
oacAtmOamVclAisRdiEnableEnable Remote Defect Indication
OAM cell generation if an Alarm
Indication Signal OAM cell is received,
or if a defect is detected on the PVCro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.4 |
oacAtmOamVclSegmentContinuityCheckEnableEnable Segment Loss of Continuity
cells detect on the PVC.Enable generation of
Segment Continuity Check
cells on the PVC.ro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.5 |
oacAtmOamVclEndContinuityCheckEnableEnable End to End Loss of Continuity
cells detect on the PVC.Enable generation of
End to End Continuity Check
cells on the PVC.ro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.6 |
oacAtmOamVclLoopbackTxIntervalFrequency of OAM loopback cell
are generated on this virtual channelro Integer32 .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.7 |
oacAtmOamVclLoopbackTxRetryFrequencyFrequency of OAM loopback cell
are generated on this virtual channel,
when a change has occured, that is to
say either no reception of the last
loopback cell, or reception of the
last loopback cellro Integer32 .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.8 |
oacAtmOamVclLoopbackTxRetryUpCountCounter of consecutive received loopback cells,
before vcl is considered as being upro Integer32 .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.9 |
oacAtmOamVclLoopbackTxRetryDownCountCounter of consecutive non received loopback cells,
before vcl is considered as being downro Integer32 .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.10 |
oacAtmOamVclAlarmStateThis object indicates the current
alarm status of the VCL, when error monitoring
is activated on the VCL. Value indicates
the different alarm states tha the VCL can take.
Those alarms can be combined together.
The unknown state indicates that the
alarm status of this VCL cannot be determined.
cc_seg_loc(1),cc_ete_loc(2),
lb_seg_alarm(4),lb_ete_alarm(8),
ais_alarm(16),rdi_alarm(32),other(64)ro Integer32 .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.11 |
oacAtmOamVclAlarmStateLastChangeThe value of sysUpTime object at the time this VCL
entered its current alarm status. If the current state
was entered prior to the last re-initialization of the
agent, then this object contains a zero value.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.12 |
oacAtmOamVclAisRdiRetryDownCountNumber of consecutive OAM AIS/RDI cells received.
The range is 3 to 60. The default is 3.ro Integer32 .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.13 |
oacAtmOamVclAisRdiRetryUpTimerNumber of seconds with no OAM AIS/RDI cells received.
The range is 3 to 60 seconds . The default is 3 seconds.ro Integer32 .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.14 |
oacAtmOamVclPvcIntrusiveEnable OAM Intrusivity against Pvcro Enumeration .1.3.6.1.4.1.13191.10.3.2.2.1.2.1.15 |
oacAtmOamVclCountersTableAn index into table oacAtmOamVclCountersTable SEQUENCE OF OacAtmOamVclCountersEntry .1.3.6.1.4.1.13191.10.3.2.2.1.3 |
oacAtmOamVclCountersEntryAn index into table oacAtmOamVclCountersTable OacAtmOamVclCountersEntry .1.3.6.1.4.1.13191.10.3.2.2.1.3.1 |
oacAtmOamVclOamCellsReceivedNumber of received oam cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.1 |
oacAtmOamVclEndLoopbackInNumber of received non looped
end to end oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.2 |
oacAtmOamVclSegLoopbackInNumber of received non looped
segment oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.3 |
oacAtmOamVclEndLoopInNumber of received looped end
to end oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.4 |
oacAtmOamVclSegLoopInNumber of received looped segment
oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.5 |
oacAtmOamVclAisInNumber of received oam ais cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.6 |
oacAtmOamVclRdiInNumber of received oam rdi cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.7 |
oacAtmOamVclSegCCInNumber of received oam end to end continuity check cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.8 |
oacAtmOamVclEndCCInNumber of received oam segment continuity check cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.9 |
oacAtmOamVclOamCellsSentNumber of sent oam cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.10 |
oacAtmOamVclEndLoopbackOutNumber of sent non looped end to end oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.11 |
oacAtmOamVclSegLoopbackOutNumber of sent non looped segment oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.12 |
oacAtmOamVclEndLoopOutNumber of sent looped end to end oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.13 |
oacAtmOamVclSegLoopOutNumber of sent looped segment oam loopback cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.14 |
oacAtmOamVclAisOutNumber of sent oam ais cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.15 |
oacAtmOamVclRdiOutNumber of sent oam rdi cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.16 |
oacAtmOamVclSegCCOutNumber of sent oam end to end continuity check cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.17 |
oacAtmOamVclEndCCOutNumber of sent oam segment continuity check cellsro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.18 |
oacAtmOamVclOamCellsDroppedNumber of received oam cells that are ignored and droppedro Counter32 .1.3.6.1.4.1.13191.10.3.2.2.1.3.1.19 |
oacAtmOamStatNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.2.2.2 |
oacAtmOamStatConformance OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.2.2.3 |
oacAtmOamStatGroups OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.2.2.3.1 |
oacAtmOamStatCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.2.2.3.2 |