ONEACCESS-MISC-CONFIG-MIB
The ONEACCESS-MISC-CONFIG-MIB module manages configuration parameters for OneAccess network access servers, specifically enforcing strict octet string length constraints to ensure data integrity during device provisioning. This module facilitates the validation of string-based configuration elements to prevent parsing errors and maintain stable device operation within the OneAccess infrastructure.
Imported Objects
Objects
51 total| Object Name |
|---|
oacMiscConfigMIBFixed the issues related to octet string range MODULE-IDENTITY .1.3.6.1.4.1.13191.1.100.2003 |
oacMiscConfig OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21 |
oacTelnetServerConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.1 |
oacTelnetServerBindInterfaceTableThis is for displaying all the users who are logged into device. SEQUENCE OF OacTelnetServerBindInterfaceEntry .1.3.6.1.4.1.13191.10.3.4.21.1.1 |
oacTelnetServerBindInterfaceEntryEach entry in the table is identified by the unique session id. OacTelnetServerBindInterfaceEntry .1.3.6.1.4.1.13191.10.3.4.21.1.1.1 |
oacTelnetServerBindInterfaceIndexThe interface index to which the Telnet server will bind.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.13191.10.3.4.21.1.1.1.1 |
oacTelnetServerBindInterfaceNameThe name of the interface to which the telnet server will bind.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.1.1.1.2 |
oacTelnetServerBindInterfaceRowStatusRow status for this entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.1.1.1.3 |
oacTelnetServerBindAclIt is possible to restrict access to telnet clients by using a list of addresses standing for the list of permitted source IP addresses.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.1.2 |
oacTelnetServerIdleTimeoutIf a connected telnet client is inactive during a certain time, it is disconnected. By default, any inactive telnet client is disconnected after 10 minutes.rw Unsigned32 UNITS "seconds" .1.3.6.1.4.1.13191.10.3.4.21.1.3 |
oacTelnetServerLogEnableRemote connections to the telnet server can be logged by enabling log enable.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.1.4 |
oacTelnetServerLogFileSizeBy default, the log file size is 8200 bytes.rw INTEGER .1.3.6.1.4.1.13191.10.3.4.21.1.5 |
oacSyslogServerConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.2 |
oacSyslogServerTableTable to configure remote syslog servers. SEQUENCE OF OacSyslogServerEntry .1.3.6.1.4.1.13191.10.3.4.21.2.1 |
oacSyslogServerEntryAn entry for a syslog server. OacSyslogServerEntry .1.3.6.1.4.1.13191.10.3.4.21.2.1.1 |
oacSyslogServerAddressThe remote syslog server IP address, or hostname.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.2.1.1.1 |
oacSyslogServerFacilityNumfacility number, ranging from 0 up to 23. Must be set according to the server configurationrw INTEGER .1.3.6.1.4.1.13191.10.3.4.21.2.1.1.2 |
oacSyslogServerInterfaceThe interface which this syslog client should used to send log messages to the configured remote syslog server.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.13191.10.3.4.21.2.1.1.3 |
oacSyslogServerRowStatusRow status for this entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.2.1.1.4 |
oacSyslogMaxServersmaximum number of syslog servers that can be configured.rw INTEGER .1.3.6.1.4.1.13191.10.3.4.21.2.2 |
oacSntpClientConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.3 |
oacSntpClientBroadcastEnableTo configure the SNTP client in broadcast mode to accept NTP packets from any NTP broadcast server.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.3.1 |
oacSntpRemoteServerTableTable to configure the SNTP client to request NTP packets from a specified NTP server SEQUENCE OF OacSntpRemoteServerEntry .1.3.6.1.4.1.13191.10.3.4.21.3.2 |
oacSntpRemoteServerEntryEntry for the remote sntp server. OacSntpRemoteServerEntry .1.3.6.1.4.1.13191.10.3.4.21.3.2.1 |
oacSntpRemoteServerAddressThe sntp remote server info.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.3.2.1.1 |
oacSntpRemoteServerInterfaceInterface thru which the client requests the ntp servers.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.13191.10.3.4.21.3.2.1.2 |
oacSntpRemoteServerRowStatusRow status for this entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.3.2.1.3 |
oacSntpClientPollIntervalThe duration between two requests sent to the NTP server when synchronized.rw Unsigned32 UNITS "seconds" .1.3.6.1.4.1.13191.10.3.4.21.3.3 |
oacBannerConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.4 |
oacConfigBannerSeqTableThis table holds upto 40 banner messages. SEQUENCE OF OacConfigBannerSeqEntry .1.3.6.1.4.1.13191.10.3.4.21.4.1 |
oacConfigBannerSeqEntryEach entry will hold one banner string OacConfigBannerSeqEntry .1.3.6.1.4.1.13191.10.3.4.21.4.1.1 |
oacConfigBannerTypemotd is for the text displayed when attempting to log in, whereas exec is for the text displayed when logged in.rw Enumeration .1.3.6.1.4.1.13191.10.3.4.21.4.1.1.1 |
oacConfigBannerSequenceThe maximum number of strings that can be stored are 40.rw INTEGER .1.3.6.1.4.1.13191.10.3.4.21.4.1.1.2 |
oacConfigBannerStringbanner test is a set of string maximum upto 255 characters.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.4.1.1.3 |
oacConfigBannerSeqRowStatusThe row status of this entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.4.1.1.4 |
oacConfigMotdBannerbanner text without a sequence number displayed when attempting to login.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.4.2 |
oacConfigExecBannerbanner text without a sequence number displayed when logged in.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.4.3 |
oacDateAndTimeConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.5 |
oacMiscConfigDateAndTimeCurrent date and timerw DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.5.1 |
oacConfigClockDstTableEntry for day light saving this table SEQUENCE OF OacConfigClockDstEntry .1.3.6.1.4.1.13191.10.3.4.21.5.2 |
oacConfigClockDstEntryEntry for this table. OacConfigClockDstEntry .1.3.6.1.4.1.13191.10.3.4.21.5.2.1 |
oacClockDstNameoacClockDstName is an arbitrary string that can ease readability.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.5.2.1.1 |
oacClockDstSummerStartWeekdesignates the week when the summer time startsrw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.5.2.1.2 |
oacClockDstSummerStartDateSummer day light saving start daterw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.5.2.1.3 |
oacClockDstWinterStartWeekdesignates the week when the winter time startsrw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.5.2.1.4 |
oacClockDstWinterStartDateWinter day light saving start time.rw OCTET STRING .1.3.6.1.4.1.13191.10.3.4.21.5.2.1.5 |
oacClockDstRowStatusRowStatus for this entry.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.13191.10.3.4.21.5.2.1.6 |
oacMiscConfigConformance OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.6 |
oacMiscConfigGroups OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.6.1 |
oacMiscConfigGroupGroup of Misc Configuration objects. Unknown .1.3.6.1.4.1.13191.10.3.4.21.6.1.1 |
oacMiscCompls OBJECT IDENTIFIER .1.3.6.1.4.1.13191.10.3.4.21.6.2 |
More MIBs from OneAccess
Browse all OneAccessMIBs →The ONEACCESS-VOICE-MIB provides managed objects for monitoring and controlling voice service parameters, including call session states, codec configurations, and QoS metrics, on OneAccess network access devices.
The OA-QOS-MIB module facilitates the monitoring and management of Quality of Service (QoS) parameters, specifically tracking traffic classification policies, queue depths, and bandwidth allocation statistics on OA (Open Access) network infrastructure. It enables administrators to verify service level agreement (SLA) compliance by exposing real-time metrics on packet dropping rates, latency, and jitter across prioritized traffic flows.
The OneAccess-RoundTripTime-MIB provides vendor-specific SNMP objects for monitoring network latency and round-trip time metrics on OneAccess broadband aggregation and edge routers. This module enables the tracking of path delay performance to facilitate troubleshooting of service quality and network congestion issues.
ONEACCESS-GLOBAL-REG defines the hierarchical namespace structure for OneAccess product-specific and generic MIB modules, organizing device identification and registration data under the `oacRegistration` and `oacProductSpecific` branches to enable standardized SNMP management of OneAccess architecture devices.
The ONEACCESS-JITTER-MIB module enables monitoring of network jitter and latency metrics on OneAccess broadband aggregation and edge routers. It provides specific counters and gauges to track packet delay variation, facilitating performance analysis for real-time traffic services such as VoIP and video streaming.
The OA-ZBFW-STATUS-MIB provides SNMP access to real-time operational status indicators for OAC ZBFW (Zone-Based Firewall) appliances, specifically monitoring session states, interface link status, and firewall engine health metrics.