NSCRTV-ROOT
AI MIB Summary
Standard SNMP MIB module defining data structures for NSCRTV-ROOT.
154
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
154 total| Object Name |
|---|
nscrtvRoot OBJECT IDENTIFIER .1.3.6.1.4.1.17409 |
nscrtvHFCemsTree OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1 |
hfcColdStartHfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after the success of transponder sent registration. NOTIFICATION-TYPE .1.3.6.1.4.1.17409.1.0.0 |
hfcAlarmEventWhen detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the parameters only need to bind the alarm first three variables. NOTIFICATION-TYPE .1.3.6.1.4.1.17409.1.0.1 |
hfcWarmStartHfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after the completion of transponder sent registration. NOTIFICATION-TYPE .1.3.6.1.4.1.17409.1.0.2 |
propertyIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.1 |
analogPropertyTableAttribute Table simulation parameters SEQUENCE OF AnalogPropertyEntry .1.3.6.1.4.1.17409.1.1.1 |
analogPropertyEntryAttribute Table simulation parameters head. OID purpose as a table index,Its coding method is'lengthooOID'ooOID former two members'1.3'According to '1'and'3'respectively coding,Instead of ordinary OID encoding (0x2B). AnalogPropertyEntry .1.3.6.1.4.1.17409.1.1.1.1 |
analogParameterOIDindexro OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.1.1.1.1 |
alarmEnableAlarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning Bit 0: Alarm enable low Bit 1: Alarm enable low Bit 2: Alarm enable high Bit 3: Alarm enable high Bit 4 ~ 7 reservations should be 0 This object should be stored in nonvolatile memory.rw OCTET STRING .1.3.6.1.4.1.17409.1.1.1.1.2 |
analogAlarmStateThe parameters of the current state of alarm.ro Enumeration .1.3.6.1.4.1.17409.1.1.1.1.3 |
analogAlarmHIHIAlarm HIHI high threshold value. This object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.1.1.1.4 |
analogAlarmHIHI high alarm threshold value. This object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.1.1.1.5 |
analogAlarmLOLO low alarm threshold value. This object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.1.1.1.6 |
analogAlarmLOLOAlarm LOLO very low threshold value. This object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.1.1.1.7 |
analogAlarmDeadbandDead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm can be removed. This object should be stored in nonvolatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.1.1.1.8 |
discretePropertyTableDiscrete Attribute Table. SEQUENCE OF DiscretePropertyEntry .1.3.6.1.4.1.17409.1.1.2 |
discretePropertyEntryAttribute Table discrete head. OID coding methods with simulation attribute table DiscretePropertyEntry .1.3.6.1.4.1.17409.1.1.2.1 |
discreteParameterOIDAttribute Table discrete index 1: Parameters OID.ro OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.1.2.1.1 |
discreteAlarmValueAttribute Table discrete index 2: parameter values. When the equipment value of this parameter values, and so will be dealt with a warning.ro INTEGER .1.3.6.1.4.1.17409.1.1.2.1.2 |
discreteAlarmEnableWhen the alarm so that it can open the (2 or 3), this parameter allows for alarm processing. If the alarm so that it can shut down (1), alarm processing will be carried out. This object default values for the disable (1). This object should be stored in non-volatile memory.rw Enumeration .1.3.6.1.4.1.17409.1.1.2.1.3 |
discreteAlarmStateThe parameters of the current state of alarm.ro Enumeration .1.3.6.1.4.1.17409.1.1.2.1.4 |
currentAlarmTableThe current warning Table. SEQUENCE OF CurrentAlarmEntry .1.3.6.1.4.1.17409.1.1.3 |
currentAlarmEntryThe current warning Table Head. OID coding methods with simulation attribute table. CurrentAlarmEntry .1.3.6.1.4.1.17409.1.1.3.1 |
currentAlarmOIDNE, currently in a state of alarm parameters OID Index, and attribute the alarm in the table corresponding parameters OID.ro OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.1.3.1.1 |
currentAlarmStateWarning parameters of the current state of alarm.ro Enumeration .1.3.6.1.4.1.17409.1.1.3.1.2 |
currentAlarmValueAlarm parameter's value.ro INTEGER .1.3.6.1.4.1.17409.1.1.3.1.3 |
alarmsIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.2 |
alarmLogNumberOfEntriesAlarm record number of records in the table.ro INTEGER .1.3.6.1.4.1.17409.1.2.1 |
alarmLogLastIndexRecently a warning the index of the records.ro INTEGER .1.3.6.1.4.1.17409.1.2.2 |
alarmLogTableAlarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news. SEQUENCE OF AlarmLogEntry .1.3.6.1.4.1.17409.1.2.3 |
alarmLogEntryAlarm Sheet Head. AlarmLogEntry .1.3.6.1.4.1.17409.1.2.3.1 |
alarmLogIndexThe only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32,767, a record index of the re-starts at 1. Acting under the management of storage capacity can be the first choice to delete those records, the specific details in this not to achieve provisions.ro INTEGER .1.3.6.1.4.1.17409.1.2.3.1.1 |
alarmLogInformationAlarm record information, multi-byte strings, defined as follows: Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte) Byte 5: Alarm types (enumeration, definitions see behind) Byte 6: Alarm value after commonNeStatus Byte 7 ~ m: Alarm parameters object identifier (Basic Encoding Rules (ASN.1)) Byte n ~ z: Alarm parameter values (Basic Encoding Rules (ASN.1)) Alarm enumerated types: 1 NOMINAL 2 HIHI 3 HI 4 LO 5 LOLO 6 Discrete Major 7 Discrete Minorro OCTET STRING ( SIZE ( 17..255 ) ) .1.3.6.1.4.1.17409.1.2.3.1.2 |
alarmTextThis trap targets for the needs of information contained in a text field transponder information is achievable. The field contains the text of the object depends on the definition of alarm parameters, it is uncertain, This object can not access provisions. DisplayString (SNMPv2-TC) .1.3.6.1.4.1.17409.1.2.4 |
commonIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3 |
commonAdminGroup OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.1 |
commonNELogicalIDThe logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE. This target value should be stored in non-volatile memory.rw OCTET STRING .1.3.6.1.4.1.17409.1.3.1.1 |
commonNEVendorNE equipment manufacturers.ro DisplayString .1.3.6.1.4.1.17409.1.3.1.2 |
commonNEModelNumberNE equipment models.ro DisplayString .1.3.6.1.4.1.17409.1.3.1.3 |
commonNESerialNumberNE equipment serial numbers.ro DisplayString .1.3.6.1.4.1.17409.1.3.1.4 |
commonNEVendorInfoNE equipment suppliers other special designated information.ro DisplayString .1.3.6.1.4.1.17409.1.3.1.5 |
commonNEStatusWith 7.5.4 STATRESP PDU parameters in the corresponding Status Bit 0: CHNLRQST Bit 1: CNTNRM Bit 2: CNTCUR Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD1 Bit 6: RSVD2 Bit 7: RSVD3ro OCTET STRING .1.3.6.1.4.1.17409.1.3.1.6 |
commonResetWrite'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', had no effect on equipment.rw Enumeration .1.3.6.1.4.1.17409.1.3.1.7 |
commonAlarmDetectionControlThis object used to control the Alarm Detection NE.rw Enumeration .1.3.6.1.4.1.17409.1.3.1.8 |
commonNetworkAddressNE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the MAC order or through local vendors to set up Interface.ro NetworkAddress .1.3.6.1.4.1.17409.1.3.1.9 |
commonCheckCodeThis target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions. The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should have hfcColdStart hfcWarmStart traps. When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce or hfcWarmStart traps hfcColdStart.rw INTEGER .1.3.6.1.4.1.17409.1.3.1.10 |
commonTrapCommunityStringDefinition of Community Trap string. The default value is' public '. The value of this object should be stored in non-volatile memory.rw OCTET STRING .1.3.6.1.4.1.17409.1.3.1.11 |
commonTamperStatusThe safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised.ro Enumeration .1.3.6.1.4.1.17409.1.3.1.12 |
commonInternalTemperatureNE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table.ro INTEGER (-128..127) .1.3.6.1.4.1.17409.1.3.1.13 |
commonTimeNE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds).rw INTEGER .1.3.6.1.4.1.17409.1.3.1.14 |
commonVarBindingsThis object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number bundled.ro INTEGER .1.3.6.1.4.1.17409.1.3.1.15 |
commonResetCauseNE said the reasons for the recent reduction.ro Enumeration .1.3.6.1.4.1.17409.1.3.1.16 |
commonCraftStatusNE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface without affecting the state of its MAC interface functions; If we do not support the local interface, and its value is disconnected.ro Enumeration .1.3.6.1.4.1.17409.1.3.1.17 |
commonDeviceOIDThis OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc).ro OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.1.18 |
commonDeviceIdThe contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages.ro OCTET STRING .1.3.6.1.4.1.17409.1.3.1.19 |
commondownloadrw Enumeration .1.3.6.1.4.1.17409.1.3.1.20 |
commonAdminUseRf OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.2 |
commonMACGroup OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.2.1 |
commonMacAddress OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.2.1.1 |
commonPhysAddressNE MAC (physical) address.ro OCTET STRING .1.3.6.1.4.1.17409.1.3.2.1.1.1 |
commonMaxMulticastAddressesNE equipment to support the greatest number of multicast addresses.ro INTEGER .1.3.6.1.4.1.17409.1.3.2.1.1.2 |
commonMulticastAddressTableMulticast addresses Table, the value of this object should be stored in nonvolatile memory. SEQUENCE OF CommonMulticastAddressEntry .1.3.6.1.4.1.17409.1.3.2.1.1.3 |
commonMulticastAddressEntryMulticast addresses Table Head. CommonMulticastAddressEntry .1.3.6.1.4.1.17409.1.3.2.1.1.3.1 |
commonMulticastAddressIndexMulticast addresses Index.ro INTEGER .1.3.6.1.4.1.17409.1.3.2.1.1.3.1.1 |
commonMulticastAddressNumberMulticast addresses,I/Gbitrw OCTET STRING .1.3.6.1.4.1.17409.1.3.2.1.1.3.1.2 |
commonBackoffParams OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.2.1.2 |
commonBackoffPeriodBackoff algorithm benchmark time (ms), initialize the default value of 6 ms. The value of this object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.3.2.1.2.1 |
commonACKTimeoutWindowNE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms. The value of this object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.3.2.1.2.2 |
commonMaximumMACLayerRetriesNE data packets sent the greatest number of re-examination. Initialize the default value is 16. The value of this object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.3.2.1.2.3 |
commonMaxPayloadSizeFrom top to bottom line channel packet supported by the largest payload (payload) the length of.ro INTEGER .1.3.6.1.4.1.17409.1.3.2.1.2.4 |
commonBackoffMinimumExponentThe standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6. This value may not exceed commonBackoffMaximumValue value. The value of this object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.3.2.1.2.5 |
commonBackoffMaximumExponentThe body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15. This value shall be not less than commonBackoffMinimum value. The value of this object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.3.2.1.2.6 |
commonMacStats OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.2.1.3 |
commonForwardPathLOSEventsLOS downlink channel in the number of reset to 0.rw Counter .1.3.6.1.4.1.17409.1.3.2.1.3.1 |
commonForwardPathFramingErrorsDownlink Channel frames wrong number reset to 0.rw Counter .1.3.6.1.4.1.17409.1.3.2.1.3.2 |
commonForwardPathCRCErrorsCRC errors down the number of reset to 0.rw Counter .1.3.6.1.4.1.17409.1.3.2.1.3.3 |
commonInvalidMacCmdsInvalid MAC layer order wrong number reset to 0.rw Counter .1.3.6.1.4.1.17409.1.3.2.1.3.4 |
commonBackwardPathCollisionTimesUplink Packet collision frequency, reset to 0.rw Counter .1.3.6.1.4.1.17409.1.3.2.1.3.5 |
commonRfGroup OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.2.2 |
commonReturnPathFrequencyChannel uplink frequency units Hz. The value of this object should be stored in non-volatile memory.ro INTEGER .1.3.6.1.4.1.17409.1.3.2.2.1 |
commonForwardPathFrequencyDownlink frequency channel, flat Hz. The value of this object should be stored in non-volatile memory.ro INTEGER .1.3.6.1.4.1.17409.1.3.2.2.2 |
commonProvisionedReturnPowerLevelUpstream channel power levels and units for dBuV. When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value. The value of this object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.3.2.2.3 |
commonForwardPathReceiveLevelDownlink Channel receive power levels, units dBuV.ro INTEGER .1.3.6.1.4.1.17409.1.3.2.2.4 |
commonMaxReturnPowerThe largest upstream channel power levels and units for dBuV. The value of this object should be stored in non-volatile memory.rw INTEGER .1.3.6.1.4.1.17409.1.3.2.2.5 |
commonAdminUseEthernet OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.3 |
commonAgentGroup OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.3.1 |
commonAgentBootWayStarting Method Actingrw Enumeration .1.3.6.1.4.1.17409.1.3.3.1.1 |
commonAgentResetActing Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had no effect on.rw Enumeration .1.3.6.1.4.1.17409.1.3.3.1.2 |
commonAgentMaxTrapsActing detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values.rw INTEGER .1.3.6.1.4.1.17409.1.3.3.1.3 |
commonAgentTrapMinIntervalActing TRAP send the minimum spacing units for s.rw INTEGER .1.3.6.1.4.1.17409.1.3.3.1.4 |
commonAgentTrapMaxIntervalActing TRAP send the largest spacing units for s.rw INTEGER .1.3.6.1.4.1.17409.1.3.3.1.5 |
commonTrapAckThe variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the variables in alarmLogInformation MIB and the same warning. Agents received after the adoption of alarmLogInformation management can clearly know the host response is a warning which Trap information, thereby stop the alarm information re the Trap.rw OCTET STRING ( SIZE ( 17..255 ) ) .1.3.6.1.4.1.17409.1.3.3.1.6 |
commonAgentTrapTableActing Information Table TRAP. SEQUENCE OF CommonAgentTrapEntry .1.3.6.1.4.1.17409.1.3.3.1.7 |
commonAgentTrapEntryActing Head TRAP Information Table. CommonAgentTrapEntry .1.3.6.1.4.1.17409.1.3.3.1.7.1 |
commonAgentTrapIndexTRAP Table Index.ro INTEGER .1.3.6.1.4.1.17409.1.3.3.1.7.1.1 |
commonAgentTrapIPWhen the purpose of the TRAP host's IP address.rw IpAddress .1.3.6.1.4.1.17409.1.3.3.1.7.1.2 |
commonAgentTrapCommunitySend the Community string TRAP.rw DisplayString .1.3.6.1.4.1.17409.1.3.3.1.7.1.3 |
commonAgentTrapStatusIt said the opening of the TRAP.rw Enumeration .1.3.6.1.4.1.17409.1.3.3.1.7.1.4 |
commonDeviceGroup OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.3.2 |
commonDeviceNumThe agent said that the current management is the number of devices.rw INTEGER .1.3.6.1.4.1.17409.1.3.3.2.1 |
commonDeviceInfoTableActing is currently public information management equipment List. SEQUENCE OF CommonDeviceInfoEntry .1.3.6.1.4.1.17409.1.3.3.2.2 |
commonDeviceInfoEntryActing is currently public information management equipment list Table Head. CommonDeviceInfoEntry .1.3.6.1.4.1.17409.1.3.3.2.2.1 |
commonDeviceSlotActing is currently under the management of the equipment list of public information table Index.ro INTEGER .1.3.6.1.4.1.17409.1.3.3.2.2.1.1 |
commonDevicesIDDesignated equipment manufacturers logo.ro OCTET STRING .1.3.6.1.4.1.17409.1.3.3.2.2.1.2 |
commonDeviceVendorEquipment manufacturers.ro DisplayString .1.3.6.1.4.1.17409.1.3.3.2.2.1.3 |
commonDeviceModelNumberEquipment Model.ro DisplayString .1.3.6.1.4.1.17409.1.3.3.2.2.1.4 |
commonDeviceSerialNumberThe string of equipment.ro DisplayString .1.3.6.1.4.1.17409.1.3.3.2.2.1.5 |
commonDeviceVendorInfoEquipment suppliers of other special designated information.ro DisplayString .1.3.6.1.4.1.17409.1.3.3.2.2.1.6 |
commonDeviceStatusThe state equipment Bit 0: RSVD0 Bit 1: RSVD1 Bit 2: RSVD2 Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD5 Bit 6: RSVD6 Bit 7: RSVD7ro OCTET STRING .1.3.6.1.4.1.17409.1.3.3.2.2.1.7 |
commonDeviceResetWrite'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', had no effect on equipment.rw Enumeration .1.3.6.1.4.1.17409.1.3.3.2.2.1.8 |
commonDeviceAlarmDetectionControlThis object used to control equipment Alarm Detection.rw Enumeration .1.3.6.1.4.1.17409.1.3.3.2.2.1.9 |
commonDeviceMACAddressEquipment MAC address.ro NetworkAddress .1.3.6.1.4.1.17409.1.3.3.2.2.1.10 |
commonDeviceTamperStatusReport of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised.ro Enumeration .1.3.6.1.4.1.17409.1.3.3.2.2.1.11 |
commonDeviceInternalTemperatureEquipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table.ro INTEGER (-128..127) .1.3.6.1.4.1.17409.1.3.3.2.2.1.12 |
commonDeviceResetCauseEquipment that the reasons for the recent reduction.ro Enumeration .1.3.6.1.4.1.17409.1.3.3.2.2.1.13 |
commonDeviceCraftStatusThis object interface that local equipment (such as RS232 or RS485 interface) state.ro Enumeration .1.3.6.1.4.1.17409.1.3.3.2.2.1.14 |
commonDevicesOIDGoals identifier string, point to a concrete realization of the equipment.ro OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.3.3.2.2.1.15 |
commonDeviceAcctEquipment that the accumulated work time, units of s.ro Counter .1.3.6.1.4.1.17409.1.3.3.2.2.1.16 |
commonDeviceNameEquipment Name.ro DisplayString .1.3.6.1.4.1.17409.1.3.3.2.2.1.17 |
commonDeviceMFDDate of production equipment.ro DisplayString .1.3.6.1.4.1.17409.1.3.3.2.2.1.18 |
commonDeviceFWFirmware information equipment.ro DisplayString .1.3.6.1.4.1.17409.1.3.3.2.2.1.19 |
tvmodIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.4 |
qammodIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.5 |
otdIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.6 |
otxIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.7 |
uporIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.8 |
dorIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.9 |
fnIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.10 |
oaIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.11 |
oaVendorOIDThis object provides manufacturers of optical amplifier MIB expansion. Without the expansion, this should be targeting at the optical amplifier nodes oaIdent.ro OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.11.1 |
oaOutputOpticalPowerThe output optical power units to 0.1 dBm, the object attributes required to register an entry MIB.ro INTEGER ( 0..65535 ) .1.3.6.1.4.1.17409.1.11.2 |
oaInputOpticalPowerInput optical power units to 0.1 dBm, the object attributes required to register an entry MIB.ro INTEGER ( -128..127 ) .1.3.6.1.4.1.17409.1.11.3 |
oaPumpTableEDFA laser pump Information Table. SEQUENCE OF OaPumpEntry .1.3.6.1.4.1.17409.1.11.4 |
oaPumpEntryEach laser-pumped optical amplifier Information Table Head. OaPumpEntry .1.3.6.1.4.1.17409.1.11.4.1 |
oaPumpIndexLaser-pumped optical amplifier index value.ro INTEGER .1.3.6.1.4.1.17409.1.11.4.1.1 |
oaPumpBIASThe pump laser bias current, flat mA, this attribute MIB objects require an entry in the register.ro INTEGER ( 0..65535 ) .1.3.6.1.4.1.17409.1.11.4.1.2 |
oaPumpTECCurrent laser pump refrigeration unit is 0.01 A, this attribute MIB objects require an entry in the register.ro INTEGER ( -32768..32767 ) .1.3.6.1.4.1.17409.1.11.4.1.3 |
oaPumpTempLaser pump temperature, units of 0.10 C, this attribute MIB objects require an entry in the register.ro INTEGER ( 0..32768 ) .1.3.6.1.4.1.17409.1.11.4.1.4 |
oaNumberDCPowerSupplyThe number of internal DC power supply, 0 expressed transponder does not support this function.ro INTEGER ( 0..16 ) .1.3.6.1.4.1.17409.1.11.5 |
oaDCPowerSupplyModePower supply mode: load sharing, standby switching or an independent power supply.ro Enumeration .1.3.6.1.4.1.17409.1.11.6 |
oaDCPowerTableDC Power Information Table. SEQUENCE OF OaDCPowerEntry .1.3.6.1.4.1.17409.1.11.7 |
oaDCPowerEntryDC Power Information Table Head. OaDCPowerEntry .1.3.6.1.4.1.17409.1.11.7.1 |
oaDCPowerIndexDC Power Index.ro INTEGER .1.3.6.1.4.1.17409.1.11.7.1.1 |
oaDCPowerVoltageSupply voltage, the unit is 0.1 V. This attribute MIB objects require an entry in the register.ro INTEGER ( -32768..32767 ) .1.3.6.1.4.1.17409.1.11.7.1.2 |
oaDCPowerCurrentElectricity power supply unit is 0.01 A. This attribute MIB objects require an entry in the register.ro INTEGER ( 0..65535 ) .1.3.6.1.4.1.17409.1.11.7.1.3 |
oaDCPowerNameIndicate the name of the power supply, for example: 24 V DC power supply. This field value by the user, should at least be marked with a number of power supply voltage and distinguish between each other. When the object of this table have a warning, that this object should be put into the name of alarmText hfcAlarmEvent traps in the target.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.17409.1.11.7.1.4 |
oaOutputOpticalPowerSetThe output optical power control ,units to 0.1 dBmrw INTEGER ( 0..65535 ) .1.3.6.1.4.1.17409.1.11.11 |
oaGainSetunits to 0.1 dBrw INTEGER ( 0..65535 ) .1.3.6.1.4.1.17409.1.11.12 |
powerSupplyStatusAReturns the operating status of power supply A.ro Enumeration .1.3.6.1.4.1.17409.1.11.32 |
powerSupplyStatusBReturns the operating status of power supply B.ro Enumeration .1.3.6.1.4.1.17409.1.11.33 |
addIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.12 |
cacIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.13 |
lineIdent OBJECT IDENTIFIER .1.3.6.1.4.1.17409.1.14 |