Home/Catalog/NIMBLE-TRAP-MIB

NIMBLE-TRAP-MIB

AI MIB Summary

The NIMBLE-TRAP-MIB defines the Structure of Management Information (SMI) for generating SNMPv2 traps from HPE Nimble Storage arrays to report critical hardware and software events, including disk failures, controller status changes, and capacity thresholds.

Alert SMI Information for Nimble
Main OID:
nimble_traps.1.3.6.1.4.1.37447.2
460
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

460 total
Object Name
nimble_trapsAlert SMI Information for Nimble
MODULE-IDENTITY
.1.3.6.1.4.1.37447.2
trapObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.37447.2.1
trapvariables
OBJECT IDENTIFIER
.1.3.6.1.4.1.37447.2.1.1
trapMsgMessage string. This is the full text of the alert message.ro
DisplayString
.1.3.6.1.4.1.37447.2.1.1.1
trapSeverityThe severity level of the trap (informational, warning, error, critical).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.37447.2.1.1.2
trapOriginatorNameThe array name that originated the trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.37447.2.1.1.3
trapOriginatorSerialNumberThe serial number of the array that originated the trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.37447.2.1.1.4
trapOriginatorGroupNameThe name of the group that originated the trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.37447.2.1.1.5
trapOriginatorGroupIDThe ID of the group that originated the trap.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.37447.2.1.1.6
trapTargetThe object for which this trap was generated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.37447.2.1.1.7
trapTargetTypeThe type of object for which this trap was generated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.37447.2.1.1.8
traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.37447.2.1.2
nimbleDsdRedEntry0101DeprecatedLow writable spaceobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.101
nimbleDsdSpaceRedExitWritable space reclaimed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.102
nimbleDsdSpaceCrit0103DeprecatedCritically low writable spaceobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.103
nimbleDsdSpaceUtilizationHighHigh system utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.104
nimbleDsdSpaceUtilizationOkSystem utilization OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.105
nimbleDsdSpaceUtilizationCritCritically high system utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.106
nimbleDsdSpaceRedEntry0107DeprecatedCritically low writable spaceobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.107
nimbleDsdSpaceCrit0110DeprecatedCritically low writable spaceobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.110
nimbleDsdSpaceRedEntryCritically low writable space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.111
nimbleDsdSpaceCritCritically low writable space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.112
nimbleCtrlrExceptionUnhandled controller exception
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2001
nimbleCtrlrTakeoverController takeover occurred
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2002
nimbleCtrlrStandbyAvailStandby controller available
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2003
nimbleCtrlrStandbyUnavailStandby controller not available
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2004
nimbleCtrlrExcessiveRestartsExcessive controller restarts detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2005
nimbleServiceRebootRestarting controller to recover service
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2006
nimbleUserRebootRebooting controller on user request
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2007
nimbleUserRebootFailedFailed to reboot controller per user request
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2008
nimbleUserHaltHalting controller on user request
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2009
nimbleUserHaltFailedFailed to halt controller per user request
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2010
nimbleCtrlrStandbyUnavailInfoStandby controller not available
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2011
nimbleCtrlrStandbyUnavailWarnStandby controller not available for an extended period
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2012
nimbleCtrlrExceptionWarnUnhandled controller exception
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2013
nimbleCtrlrExceptionCritUnhandled controller exception
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2014
nimbleCtrlrStandbyUnavailWarnTimeDeprecatedStandby controller not available for an extended periodobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2015
nimbleCtrlrStandbyUnavailWarnTimeStandby controller not available for an extended period
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2016
nimbleCtrlrTakeoverWarnController takeover occurred
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2017
nimbleCtrlrFailoverDeprecatedController failover occurredobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2018
nimbleCtrlrFailoverController failover occurred
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2019
nimbleServiceStartedService started
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2101
nimbleServiceDeadRestartService stopped unexpectedly
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2102
nimbleServiceDeadNoRestartService stopped unexpectedly
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2103
nimbleServiceCreateTunnelCreated secure tunnel to Nimble Storage support
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2104
nimbleServiceTerminateTunnelTunnel to Nimble Storage support has been terminated
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2105
nimbleServiceEssentialStoppedDeprecatedService stopped unexpectedlyobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2106
nimbleServiceEssentialStoppedService stopped unexpectedly
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2107
nimbleServiceEmailAlertFailedDeprecatedFailed to send alert e-mailobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2108
nimbleServiceEmailAlertFailedFailed to send alert e-mail
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.2109
nimbleTestDbgTest alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.5000
nimbleTestInfoTest alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.5001
nimbleTestErrTest alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.5002
nimbleTestNotTest alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.5003
nimbleTestNoteTest alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.5004
nimbleTestWarnTest alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.5005
nimbleTestCritTest alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.5006
nimbleUpdateUnpackFailUnpacking update package failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6000
nimbleUpdateStartedSoftware update started
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6001
nimbleUpdateRevertReverting software to previous version
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6002
nimbleUpdateSuccessSuccessfully updated software
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6003
nimbleUpdateRollbackRolling back software
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6004
nimbleUpdatePrecheckFailUpdate package pre-check failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6005
nimbleUpdateFailMsgSoftware update failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6007
nimbleUpdateUnpackStartedUnpacking update package
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6008
nimbleUpdateUnpackDoneUnpacked update package
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6009
nimbleUpdateSwitchRootSoftware update reboot
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6010
nimbleUpdateDownloadFailedFailed to download software update package
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6011
nimbleUpdateFailTmpFsFullSoftware update failed. /tmp is full
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6012
nimbleUpdateFailScratchFsFullSoftware update failed. scratch space is full
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6013
nimbleUpdateFailVarFsFullSoftware update failed. /var is full
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6014
nimbleUpdateFailConfigFsFullSoftware update failed. Configuration space is full
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6015
nimbleUpdateFailUsbFsFullSoftware update failed. Recovery OS space is full
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6016
nimbleUpdatePkgNotFoundSoftware update package was not found
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6017
nimbleUpdatePkgWrongSigSoftware update package has wrong signature
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6018
nimbleUpdatePkgWrongCksumSoftware update package has wrong checksum
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6019
nimbleUpdateNetDegradeDeprecatedSoftware update precheck failed. Network connectivity will degrade after software updateobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6020
nimbleUpdateDisallowSoloDeprecatedSoftware update failed. Update cannot be applied while services cannot be failed over to other controllerobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6021
nimbleUpdateDisallowSoloSoftware update cannot be applied.
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6022
nimbleUpdateNetDegradeSoftware update precheck failed. Network connectivity will degrade after software update
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6023
nimbleUpdateRaidDegradeSoftware update precheck failed. RAID assembly failed on standby controller and prevents software update to proceed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6024
nimbleUpdateArrayUnreachableFailed to contact a member array during software update
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6501
nimbleUpdateArrayFailedFailed to update software on a member array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6502
nimbleUpdateArrayTimedOutSoftware update on a member array timed out
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.6503
nimbleArrayUnreachableDeprecatedA member array became unreachableobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10010
nimbleArrayReachableDeprecatedA member array became reachableobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10011
nimbleArrayUnreachableA member array is unreachable
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10012
nimbleArrayReachableA member array is reachable
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10013
nimbleUserClearedSysCacheCache cleared by user
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10101
nimbleVolSpcCurWarningUpVolume space usage over warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10200
nimbleVolSpcCurWarningDownVolume space usage below warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10201
nimbleVolSpcCurQuotaUpVolume space usage over quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10202
nimbleVolSpcCurQuotaDownVolume space usage below quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10203
nimbleVolSpcSnapWarningUpVolume snapshot space usage over warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10204
nimbleVolSpcSnapWarningDownVolume snapshot space usage below warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10205
nimbleVolSpcSnapQuotaUpVolume snapshot space usage over quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10206
nimbleVolSpcSnapQuotaDownVolume snapshot space usage below quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10207
nimbleGmVolSpcCurCritUpVolume space usage approaching quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10208
nimbleGmVolSpcCurCritDownVolume space usage below critical limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10209
nimbleGmSnapSpcCurCritUpVolume snapshot space usage approaching quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10210
nimbleGmSnapSpcCurCritDownVolume snapshot space usage below critical limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10211
nimbleGmVolSpcCurQuotaOfflineVolume being taken offline because it is above its quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10212
nimbleGmVolSpcCurQuotaSetThe quota for volume is being set to 100%% because it is above its current quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10213
nimbleGmVolSpcSnapQuotaOfflineVolume being taken offline because it is above its snapshot quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10214
nimbleGmVolSpcSnapQuotaSetThe snapshot quota for volume is being set to unlimited because it is above its snapshot quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10215
nimbleGmVolSpcCurReserveOfflineVolume being taken offline because it is above its reserve and system is out of free space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10216
nimbleGmVolSpcCurReserveSetVolume reserve is being set to zero because it is above its reserve and system is out of free space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10217
nimbleGmVolSpcSnapReserveOfflineVolume being taken offline because it is above its snapshot reserve and system is out of free space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10218
nimbleGmVolSpcSnapReserveSetVolume snapshot reserve is being set to zero because it is above its reserve and system is out of free space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10219
nimbleGmVolSpcCurWarningUpVolume space usage over warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10220
nimbleGmVolSpcCurWarningDownVolume space usage below warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10221
nimbleGmVolSpcCurQuotaUpVolume space usage is over the configured quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10222
nimbleGmVolSpcCurQuotaDownVolume space usage is now below the configured quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10223
nimbleGmVolSpcSnapWarningUpVolume snapshot space usage over warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10224
nimbleGmVolSpcSnapWarningDownVolume snapshot space usage below warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10225
nimbleGmVolSpcSnapQuotaUpVolume snapshot space usage over quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10226
nimbleGmVolSpcSnapQuotaDownVolume snapshot space usage below quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10227
nimbleVolAttrSyncDelayVolume attributes synchronization to arrays in the pool delayed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10228
nimbleGmPoolArrAssgnDeprecatedFailed to assign array to poolobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10229
nimbleGmPoolArrUnassgnDeprecatedFailed to unassign array from poolobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10230
nimbleGmVolSpcCurCritUpUnlimVolume space usage approaching quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10231
nimbleGmSnapSpcCurCritUpUnlimVolume snapshot space usage approaching quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10232
nimbleGmVolSpcReserveUpVolume space usage is above its reserve
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10233
nimbleGmVolSpcReserveDownVolume space usage is below its reserve
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10234
nimbleGmSnapSpcReserveUpVolume snapshot space usage is above its reserve
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10235
nimbleGmSnapSpcReserveDownVolume snapshot space usage is below its reserve
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10236
nimbleGmPoolMrgDeprecatedFailed to merge pools.obsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10240
nimbleVolAttrSyncSuccessVolume attributes synchronization to arrays in the pool succeeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10241
nimbleSnapAttrSyncDelaySnapshot attributes synchronization to arrays in the pool delayed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10242
nimbleSnapAttrSyncSuccessSnapshot attributes synchronization to arrays in the pool succeeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10243
nimbleGroupAttrSyncDelayConfiguration synchronization to array delayed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10244
nimbleGroupAttrSyncCompleteConfiguration synchronization completed for array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10245
nimbleGlCtrlrAttrSyncDelayDeprecatedGroup Leader Platform Configuration synchronization is delayedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10246
nimbleGlCtrlrAttrSyncCompleteDeprecatedGroup Leader Configuration synchronization completedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10247
nimbleGlCtrlrAttrSyncDelayConfiguration synchronization to array delayed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10248
nimbleGlCtrlrAttrSyncCompleteConfiguration synchronization completed for array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10249
nimbleVolMoveCompleteVolume completed move to destination pool
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10250
nimbleVolMoveAbortCompleteVolume completed aborting move to destination pool
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10251
nimbleGmPoolArrUnassgnCompleteDeprecatedCompleted unassign of array from poolobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10252
nimbleGmPoolArrUnassgnCompleteCompleted unassign of array from pool
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10253
nimbleGmPoolArrAssgnFailed to assign array to pool
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10256
nimbleGmPoolArrUnassgnFailed to unassign array from pool
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10257
nimbleGmPoolMrgFailed to merge pools.
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10260
nimbleGmVolSpcCurCritUpNonWritableVolume space usage approaching volume quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10261
nimbleGmVolSpcCurQuotaNonWritableVolume being set to non-writable because it is above its volume quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10262
nimbleGmSnapSpcCurCritUpNonWritableVolume snapshot space usage approaching snapshot quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10263
nimbleGmVolSpcSnapQuotaNonWritableVolume being set to non-writable because it is above its snapshot quota
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10264
nimbleGmVolSpcCurReserveNonWritableVolume being set to non-writable because it is above its reserve and system is out of free space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10265
nimbleGmVolSpcSnapReserveNonWritableVolume being set to non-writable because it is above its snapshot reserve and system is out of free space
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10266
nimbleSchedSnapSucceededDeprecatedScheduled snapshot succeededobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10300
nimbleSchedSnapFailedScheduled snapshot failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10301
nimbleSchedSnapSkippedExistsScheduled snapshot skipped
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10302
nimbleSchedSnapSkippedHandoverScheduled snapshot skipped
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10303
nimbleSchedSnapSucceededLagInfoDeprecatedScheduled snapshot succeededobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10304
nimbleSchedSnapFailedVmwareCredentialDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10305
nimbleSchedSnapFailedVmwareConnectionTimeoutDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10306
nimbleSchedSnapFailedVmwareConnectionRefusedDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10307
nimbleSchedSnapFailedVmwareConnectionResetDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10308
nimbleSchedSnapFailedVmwareConnectionNorouteDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10309
nimbleSchedSnapFailedVmwareConnectionSocketDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10310
nimbleSchedSnapFailedVmwareConnectionUnreachableDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10311
nimbleSchedSnapFailedVmwareDisabledDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10312
nimbleSchedSnapFailedVmwareObjectnfDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10313
nimbleSchedSnapFailedVmwarePermissionDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10314
nimbleSchedSnapFailedVmwareUkhostDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10315
nimbleSchedSnapFailedVmwareEncodingPlainDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10316
nimbleSchedSnapFailedVmwareNullDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10317
nimbleSchedSnapFailedVmwareDcnotfoundDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10318
nimbleSchedSnapFailedVmwareVolsnemptyDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10319
nimbleSchedSnapFailedVmwareUnknownDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10320
nimbleSchedSnapFailedVmwareBsizeDeprecatedScheduled snapshot succeeded with warningobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10321
nimbleSchedSnapSucceededScheduled snapshot succeeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10322
nimbleSchedSnapSucceededLagInfoScheduled snapshot succeeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10323
nimbleSchedSnapFailedVmwareDisabledDeprecatedTwoScheduled snapshot failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10324
nimbleSchedSnapFailedVmwareTimeoutDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10325
nimbleSchedSnapFailedVmwareSnapNameMaxLengthExceededDeprecatedScheduled snapshot failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10326
nimbleSchedSnapFallbackApplication synchronization failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10327
nimbleSchedSnapFailedVmwarePermissionPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10340
nimbleSchedSnapFailedVmwareObjectnfPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10341
nimbleSchedSnapFailedVmwareEncodingPlainPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10342
nimbleSchedSnapFailedVmwareNullPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10343
nimbleSchedSnapFailedVmwareDcnotfoundPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10344
nimbleSchedSnapFailedVmwareVolsnemptyPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10345
nimbleSchedSnapFailedVmwareUnknownPerVmDeprecatedFailed to synchronize with VMware vCenterobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10346
nimbleSchedSnapFailedVmwareBsizePerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10347
nimbleSchedSnapFailedVmwareDisabledPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10348
nimbleSchedSnapFailedVmwareTimeoutPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10349
nimbleSchedSnapFailedVmwareSnapNameMaxLengthExceededPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10350
nimbleSchedSnapFailedVmwareGuestToolsNotRunningPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10351
nimbleSchedSnapFailedVmwareInvalidVcenterFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10352
nimbleSchedSnapFailedVmwareBusyFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10353
nimbleSchedSnapFailedVssIncompatibleScheduled snapshot failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10354
nimbleSchedSnapFailedVmwareCredentialNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10355
nimbleSchedSnapFailedVmwareConnectionTimeoutNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10356
nimbleSchedSnapFailedVmwareConnectionRefusedNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10357
nimbleSchedSnapFailedVmwareConnectionResetNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10358
nimbleSchedSnapFailedVmwareConnectionNorouteNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10359
nimbleSchedSnapFailedVmwareConnectionSocketNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10360
nimbleSchedSnapFailedVmwareConnectionUnreachableNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10361
nimbleSchedSnapFailedVmwareUkhostNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10362
nimbleSchedSnapFailedVmwareConnectionUnknownNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10363
nimbleSchedSnapFailedVmwareTimeoutNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10364
nimbleSchedSnapFailedVmwareUnknownNwFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10365
nimbleSchedSnapFailedVmwareUnknownPerVmFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10366
nimbleSchedSnapFailedVmwareQuiescingVmFailedFailed to synchronize with VMware vCenter
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10367
nimbleGmSpaceReserveWarnUpUsed space above warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10401
nimbleGmSpaceReserveWarnDownUsed space below warning limits
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10402
nimbleGmSpaceReserveCritUpUsed space above critical level
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10403
nimbleGmSpaceReserveCritDownUsed space below critical limits
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10404
nimbleGmSpaceUtilizationOkArray space utilization OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10405
nimbleGmSpaceUtilizationInfoHigh array space utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10406
nimbleGmSpaceUtilizationHighHigh array space utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10407
nimbleGmSpaceUtilizationCritCritically high array space utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10408
nimbleGmPoolSpaceReserveWarnUpDeprecatedUsed space in the pool above warning limitobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10409
nimbleGmPoolSpaceReserveWarnDownDeprecatedUsed space in the pool below warning limitsobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10410
nimbleGmPoolSpaceReserveCritUpDeprecatedUsed space in the pool above critical levelobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10411
nimbleGmPoolSpaceReserveCritDownDeprecatedUsed space in the pool below critical limitsobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10412
nimbleGmPoolSpaceUtilizationOkDeprecatedPool space utilization OKobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10413
nimbleGmPoolSpaceUtilizationInfoDeprecatedHigh pool space utilizationobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10414
nimbleGmPoolSpaceUtilizationHighDeprecatedHigh pool space utilizationobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10415
nimbleGmPoolSpaceUtilizationCritDeprecatedCritically high pool space utilizationobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10416
nimbleGmPoolSpaceReserveWarnUpUsed space in the pool above warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10417
nimbleGmPoolSpaceReserveWarnDownUsed space in the pool below warning limits
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10418
nimbleGmPoolSpaceReserveCritUpUsed space in the pool above critical level
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10419
nimbleGmPoolSpaceReserveCritDownUsed space in the pool below critical limits
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10420
nimbleGmPoolSpaceUtilizationOkPool space utilization OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10421
nimbleGmPoolSpaceUtilizationInfoHigh pool space utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10422
nimbleGmPoolSpaceUtilizationHighHigh pool space utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10423
nimbleGmPoolSpaceUtilizationCritCritically high pool space utilization
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10424
nimbleLimitMaxOverObject count reached maximum limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10500
nimbleLimitMaxUnderObject count under maximum limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10501
nimbleLimitWarnOverObject count over warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10502
nimbleLimitWarnUnderObject count under warning limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.10503
nimbleReplSnapcollSucceededReplication succeeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11000
nimbleReplSnapcollDelayedInfoExcessive replication delay
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11001
nimbleReplSnapcollDelayedWarnExcessive replication delay
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11002
nimbleReplPartnerSyncFailPartner synchronization failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11003
nimbleReplBranchPinnedVolume replication stalled
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11004
nimbleReplHandoverCompletedVolume collection handover completed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11005
nimbleReplMultiArrayGroupReplication between multi-array scaleout group and pre-scaleout array is not supported
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11006
nimbleReplPartnerMisconfigurationReplication between a scaleout group and pre-scaleout array must be configured over the management network
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11007
nimbleReplSnapshotCorrectedDeprecatedReplication resynchronizedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11008
nimbleReplCbrRequestedDeprecatedResynchronization not supportedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11009
nimbleReplCbrNeededResynchronization not supported
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11010
nimbleReplSnapshotCorrectedDeprecated2Replication resynchronized
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11011
nimbleReplCbrRequestedDeprecated2Resynchronization not supported
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11012
nimbleReplPartnerAuthFailDeprecatedPartner authentication failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11013
nimbleReplSnapshotCorrectedReplicated snapshot resynchronized
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11014
nimbleReplCbrRequestedReplicated snapshot resynchronization not supported
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11015
nimbleReplPartnerAuthFailReplication partner authentication failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.11016
nimbleOvertempShutdownDeprecatedOvertemperature shutdownobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12000
nimbleCtrlrOvertempDeprecatedController overtemperatureobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12001
nimbleBackplaneOvertempDeprecatedBackplane over-temperatureobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12002
nimbleIscsiErroneousItorConnsiSCSI connections from initiator repeatedly closed by array due to improper target IP configuration
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12057
nimbleDiskFailedCritDeprecatedDisk failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12100
nimbleDiskFailedDeprecatedDisk failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12101
nimbleDiskAbsentDeprecatedDisk missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12102
nimbleDiskAddedDeprecatedDisk addedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12103
nimbleDiskRemovedDeprecatedDisk removedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12104
nimbleSsdFailedDeprecatedSSD failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12105
nimbleSsdAbsentDeprecatedSSD missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12106
nimbleSsdAddedDeprecatedSSD addedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12107
nimbleSsdRemovedDeprecatedSSD removedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12108
nimbleDiskInvalidLabelForeign disk detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12109
nimbleSsdInvalidLabelForeign SSD detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12110
nimbleDiskSizeMismatchDeprecatedInvalid disk size for this modelobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12111
nimbleHddFailedV2Disk failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12112
nimbleHddAbsentV2Disk missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12113
nimbleHddAddedV2Disk added
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12114
nimbleHddRemovedV2Disk removed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12115
nimbleSsdFailedV2SSD failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12116
nimbleSsdAbsentV2SSD missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12117
nimbleSsdAddedV2SSD added
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12118
nimbleSsdRemovedV2SSD removed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12119
nimbleSsdLastOneOnly one SSD drive left
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12120
nimbleHddFailedV3Disk failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12121
nimbleHddAddedV3Disk added
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12122
nimbleHddRemovedV3Disk removed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12123
nimbleSsdFailedV3SSD failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12124
nimbleSsdAddedV3SSD added
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12125
nimbleSsdRemovedV3SSD removed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12126
nimbleDiskSizeMismatchV2Invalid disk size for this shelf
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12127
nimbleSsdSizeMismatchV2Invalid SSD size for this shelf
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12128
nimbleHddFailedAfsDeprecatedDisk not supported on All Flash Shelfobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12129
nimbleHddFailedAfsDisk not supported on All-Flash Shelf
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12130
nimbleIpIfDownIP interface down
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12200
nimbleIpIfUpIP interface up
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12201
nimbleIpIfGroupUnavailDeprecatedGroup IP interface unavailableobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12202
nimbleIpIfDataUnavailDeprecatedAll Data IP interfaces unavailableobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12203
nimbleIpIfCantFailoverDeprecatedIP connectivity lostobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12204
nimbleSubnetNicMigrationDeprecatedMigrating subnet NIC configurationobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12205
nimbleSubnetNicMissingDeprecatedNIC for subnet missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12206
nimbleIpNicMigrationDeprecatedMigrating IP NIC configurationobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12207
nimbleIpNicMissingDeprecatedNIC for IP missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12208
nimbleRouteNicMigrationDeprecatedMigrating route NIC configurationobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12209
nimbleRouteNicMissingDeprecatedNIC for route missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12210
nimbleIpIfFailoverStandby controller has better network connectivity. Failing services over to standby controller
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12211
nimbleIpDupFoundDuplicate IP Address Detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12212
nimbleIpIfDiscoveryUnavailDeprecatedDiscovery IP interface unavailableobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12213
nimbleIpIfTargetUnavailDeprecatedTarget IP interfaces unavailableobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12214
nimbleIpIfGroupUnavailLink down for Group IP interface(s)
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12215
nimbleIpIfDiscoveryUnavailLink down for Discovery IP interface(s)
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12216
nimbleIpIfTargetUnavailLink down for Target IP interface(s)
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12217
nimbleIpIfDataUnavailLink down for Data IP interface(s)
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12218
nimbleIpIfIscsiDataUnavailLink down for iSCSI Data IP interface(s)
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12219
nimbleIpIfClusterDataUnavailLink down for cluster Data IP interface(s)
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12220
nimbleUnresponsiveNicDetectedUnresponsive NIC Port Detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12221
nimbleIpIfCantFailoverDeprecated2IP connectivity lost
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12222
nimbleIpIfCantFailoverNetwork connectivity lost
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12223
nimbleSensorLinearWarnSensor: Alert raised
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12301
nimbleSensorLinearClearSensor: Alert cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12302
nimbleSensorBoolWarnSensor: Alert raised
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12303
nimbleSensorBoolClearSensor: Alert cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12304
nimbleSensorDoesNotExistSensor: is missing?:
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12305
nimbleNvramBattDisabledNVRAM battery is disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12306
nimbleNvramBattDisabledCritNVRAM batteries are disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12307
nimbleNvramBattOkNVRAM battery is OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12308
nimbleTempSensorHighDepSystem temperature is warmobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12310
nimbleTempSensorLowDepSystem temperature is coldobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12311
nimbleTempSensorOkDepSystem temperature is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12312
nimbleTempSensorMissingDepTemperature sensor failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12313
nimbleTempSensorOperationalDepTemperature sensor is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12314
nimbleFanSensorHighDepFan in high speedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12315
nimbleFanSensorLowDepFan in low speedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12316
nimbleFanSensorOkDepFan is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12317
nimbleFanSensorStoppedDepFan stoppedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12318
nimbleFanSensorMissingDepFan missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12319
nimblePwrSupplySensorFailDepPower supply failobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12320
nimblePwrSupplySensorMissingDepPower supply missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12321
nimblePwrSupplySensorOkDepPower supply is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12322
nimbleTempSensorHighDep2System temperature is warmobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12323
nimbleTempSensorLowDep2System temperature is coldobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12324
nimbleTempSensorOkDep2System temperature is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12325
nimbleTempSensorMissingDep2Temperature sensor failedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12326
nimbleTempSensorOperationalDep2Temperature sensor is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12327
nimbleFanSensorHighDep2Fan in high speedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12328
nimbleFanSensorLowDep2Fan in low speedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12329
nimbleFanSensorOkDep2Fan is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12330
nimbleFanSensorStoppedDep2Fan stoppedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12331
nimbleFanSensorMissingDep2Fan missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12332
nimblePwrSupplySensorFailDep2Power supply failobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12333
nimblePwrSupplySensorMissingDep2Power supply missingobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12334
nimblePwrSupplySensorOkDep2Power supply is okobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12335
nimbleTempSensorHighDeprecatedDep2System temperature is warmobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12336
nimbleTempSensorLowSystem temperature is cold
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12337
nimbleTempSensorOkSystem temperature is OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12338
nimbleTempSensorMissingTemperature sensor failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12339
nimbleTempSensorOperationalTemperature sensor is OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12340
nimbleFanSensorHighFan is at high speed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12341
nimbleFanSensorLowFan is at low speed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12342
nimbleFanSensorOkFan is OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12343
nimbleFanSensorStoppedFan stopped
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12344
nimbleFanSensorMissingFan missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12345
nimblePwrSupplySensorFailPower supply fail
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12346
nimblePwrSupplySensorMissingPower supply missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12347
nimblePwrSupplySensorOkPower supply is OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12348
nimbleRaidDegradedRAID array degraded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12400
nimbleRaidRebuildStartRAID array rebuild started
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12401
nimbleRaidRebuildDoneRAID array rebuild is done
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12402
nimbleRaidRebuildFailReadRAID array rebuild failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12403
nimbleRaidRebuildFailRAID array rebuild failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12404
nimbleRaidDisksMissingDisks missing from RAID array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12405
nimbleRaidSpareDisk marked as spare
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12406
nimbleRaidAssemblyFailedCould not assemble RAID array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12407
nimbleRaidDegradedV2RAID array degraded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12408
nimbleRaidRebuildStartV2RAID array rebuild started
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12409
nimbleRaidRebuildDoneV2RAID array rebuild is done
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12410
nimbleRaidRebuildFailReadV2RAID array rebuild failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12411
nimbleRaidRebuildFailV2RAID array rebuild failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12412
nimbleRaidDisksMissingV2Disks missing from RAID array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12413
nimbleRaidSpareV2Disk marked as spare
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12414
nimbleRaidAssemblyFailedV2Could not assemble RAID array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12415
nimbleRaidRebuildScheduledV2RAID array rebuild scheduled
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12416
nimbleRaidRebuildStopV2RAID array rebuild stopped
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12417
nimbleIscsiMultiInitiatorDeprecatedMulti initiator loginobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12500
nimbleIscsiConnHardLimitDeprecated1Too many iscsi connections
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12501
nimbleIscsiUnalignedOpsDeprecatedToo many unaligned iscsi reads/writesobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12502
nimbleIscsiMultiInitiatorMulti initiator login
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12503
nimbleIscsiConnHardLimitDeprecated2Too many iSCSI connections
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12504
nimbleIscsiUnalignedOpsToo many unaligned iSCSI reads/writes
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12505
nimbleIscsiConnHardLimitToo many iSCSI connections
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12506
nimbleNvramBattChargingNVRAM battery is charging
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12601
nimbleNvramBattChargedNVRAM battery has finished charging
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12602
nimbleNvramFpgaVersionNVRAM version is incompatible
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12603
nimbleNvramMbeDeprecatedNVRAM card multi-bit error (MBE) detectedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12604
nimbleNvramSbeDeprecatedNVRAM card single-bit error (SBE) detectedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12605
nimbleNvramMbeNVRAM card non-correctable multi-bit error (MBE) detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12606
nimbleNvramSbeNVRAM card correctable single-bit error (SBE) detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12607
nimbleNvdimmReservedBlocksWarnNVDIMM reserved flash blocks reached the upper threshold
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12608
nimbleNvdimmReservedBlocksCritNVDIMM reserved flash blocks reached the lower threshold
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12609
nimbleNvdimmUltracapDischargedDeprecatedNVDIMM ultracap cacapcitance dischargedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12610
nimbleNvdimmUltracapDischargedNVDIMM ultracap capacitance discharged
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12612
nimbleNvramMissingNVRAM module missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12613
nimbleShelfCtrlrSideShelf controller connected to wrong side of host controller
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12701
nimbleShelfSesErrShelf SES device not ready
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12702
nimbleShelfDiskCountNot enough disk in shelf
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12704
nimbleShelfInvalidEepromSystem cannot read shelf serial number
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12705
nimbleShelfWrongSasPortDeprecatedSAS cable connected to wrong portobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12706
nimbleShelfSasExpErrSAS expander error
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12708
nimbleShelfCtrlrLoopShelf SAS loop detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12709
nimbleShelfMissingShelf appear only on one side of host controllers
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12710
nimbleShelfOrderShelf controller connection order mismatched
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12711
nimbleShelfSesMshipErrDeprecatedCannot access shelf SES deviceobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12712
nimbleShelfFailoverController failover due to shelf problem
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12713
nimbleShelfNewShelfNew Shelf detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12714
nimbleShelfDisconnectShelf is disconnected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12715
nimbleShelfChassisSwapShelf chassis swap detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12716
nimbleShelfLocIdOverLimitShelf daisy chain too long
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12717
nimbleShelfActivatedDeprecatedNew shelf is activatedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12718
nimbleShelfReconnectConnection to shelf is restored
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12719
nimbleShelfSasLinkDisabledDeprecatedSAS link disabledobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12720
nimbleShelfDiskSasLinkErrDeprecatedExcessive link error on diskobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12721
nimbleShelfWrongSasPortDeprecated2SAS cable connected to wrong port
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12730
nimbleShelfSesMshipErrDeprecated2Cannot access shelf SES device
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12731
nimbleShelfSasLinkDisabledSAS link disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12732
nimbleShelfDiskSasLinkErrExcessive link error on disk
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12733
nimbleShelfWrongSasPortSAS cable connected to wrong port
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12734
nimbleShelfSesMshipErrDeprecated3Cannot access shelf SES device
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12735
nimbleShelfSesMshipErrDeprecated4Cannot access shelf SES device
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12736
nimbleShelfActivatedV2DeprecatedNew shelf is activatedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12737
nimbleShelfSesMshipErrCannot access shelf SES device
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12738
nimbleShelfActivatedV2New shelf activated
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12739
nimblePhysMemMismatchPhysical memory detected is less than installed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.12901
nimbleVolSysLimitWarnEnterTotal number of volumes approaching system limit
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13101
nimbleVolSysLimitWarnExitTotal number of volumes below warning threshold
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13102
nimbleGmTakeoverSuccessDeprecatedDeprecatedGroup Leader role takeover succeededobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13501
nimbleGmTakeoverRejectByArrayDeprecatedGroup Leader role takeover has been rejected by a member arrayobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13502
nimbleGmTakeoverRejectByArrayGroup Leader role takeover has been rejected by a member array
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13503
nimbleGmTakeoverSuccessDeprecatedGroup Leader role takeover succeededobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13504
nimbleGmTakeoverSuccessGroup Leader role take over succeeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13505
nimbleGmMigrateFailureGroup Leader role migrate failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13506
nimbleGmGrpMrgDoneGroup merge completed successfully
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13601
nimbleGmGrpQscFailFailed to stop services on source group for group merge
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13602
nimbleGmGrpMrgRollbackDoneCompleted rollback of group merge operation
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13603
nimbleGmGrpMrgReassFailGroup merge operation is not complete on some arrays
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13604
nimbleGmGrpMrgDbFailFailed to merge configuration from source group
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13605
nimbleGmBinMigContAbortDeprecatedData Migration is getting delayed because of continuous restartsobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13701
nimbleGmBinMigContAbortData migration is delayed because of repeated restarts
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.13702
nimbleCsmodelChangedCS-Model changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14000
nimbleCsmodelUnknownCS-Model unknown
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14001
nimbleTempSensorHighDeprecatedThe system temperature is beginning to exceed the allowable operating temperature. If it continues to exceed allowed operating temperatureobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14002
nimbleOvertempShutdownDeprecated2Controller shutdown occurred due to excessive temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14003
nimbleCtrlrOvertempController exceeds allowable operating temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14004
nimbleBackplaneOvertempBackplane exceeds allowable operating temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14005
nimbleTempSensorHighDeprecated2System temperature is too high.
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14006
nimbleTempSensorCrithighDeprecatedSystem temperature continues to be high.obsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14007
nimblePwrSupplySensorCallsupportDeprecatedPower supply down revisionedobsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14008
nimbleOvertempShutdownController shutdown occurred due to excessive temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14009
nimblePwrSupplySensorCallsupportPower supply down revisioned
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14010
nimbleTempSensorHighArray temperature is too high
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14011
nimbleTempSensorCrithighArray temperature continues to be high
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14012
nimbleUpdateUnknownFirmwareAn unknown firmware version was detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14200
nimbleFcLinkUpFibre Channel link up
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14400
nimbleFcLinkDownFibre Channel link down
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14401
nimbleFcLinkNotConnectedFibre Channel link not connected
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14402
nimbleEventPurgingOldest events removed from the system
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14700
nimbleEventWarnOverEvents count reached warning threshold
NOTIFICATION-TYPE
.1.3.6.1.4.1.37447.2.1.2.14701
NIMBLE-TRAP-MIB - SNMP MIB Reference | MIBs Explorer