NETWORK-TECHNOLOGIES-GLOBAL-REG
AI MIB Summary
Standard SNMP MIB module defining data structures for NETWORK-TECHNOLOGIES-GLOBAL-REG.
89
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
89 total| Object Name |
|---|
nti OBJECT IDENTIFIER .1.3.6.1.4.1.3699 |
products OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1 |
hardware OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1 |
enviromux_MINI OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3 |
monitoring OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1 |
temperatureSensor1 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.1 |
temperatureSensor1CurrentValueCurrent value of the temperature sensor connected to port 1 in tenths of degrees . This port is the right RJ-45 sensor port. The value is expressed in the units indicated in temperatureSensor1Unit. This object is only applicable if a temperature sensor is connected to port 1.ro DecimalPointValue .1.3.6.1.4.1.3699.1.1.3.1.1.1 |
temperatureSensor1AlertCurrent alert status of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a temperature sensor is connected to port 1.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.1.2 |
temperatureSensor2 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.2 |
temperatureSensor2CurrentValueCurrent value of the temperature sensor connected to port 2 in tenths of degrees . This port is the left RJ-45 sensor port. The value is expressed in the units indicated in temperatureSensor2Unit. This object is only applicable if a temperature sensor is connected to port 2.ro DecimalPointValue .1.3.6.1.4.1.3699.1.1.3.1.2.1 |
temperatureSensor2AlertCurrent alert status of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a temperature sensor is connected to port 2.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.2.2 |
humiditySensor1 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.3 |
humiditySensor1CurrentValueCurrent integer value in tenths of percents of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.ro DecimalPointValue .1.3.6.1.4.1.3699.1.1.3.1.3.1 |
humiditySensor1AlertCurrent alert status of the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. This object is only applicable if a humidity sensor is connected to port 1.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.3.2 |
humiditySensor2 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.4 |
humiditySensor2CurrentValueCurrent integer value in tenths of percents of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a humidity sensor is connected to port 2.ro DecimalPointValue .1.3.6.1.4.1.3699.1.1.3.1.4.1 |
humiditySensor2AlertCurrent alert status of the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. A value of 0 indicates that the sensor has not crossed either of its specified thresholds, while a value of 1 indicates that it has. his object is only applicable if a humidity sensor is connected to port 2.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.4.2 |
dryContact1 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.5 |
dryContact1StatusCurrent integer value of the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.5.1 |
dryContact1AlertCurrent alert status of the dry contact sensor connected to port 1. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 1.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.5.2 |
dryContact2 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.6 |
dryContact2StatusCurrent integer value of the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.6.1 |
dryContact2AlertCurrent alert status of the dry contact sensor connected to port 2. value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 2.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.6.2 |
dryContact3 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.7 |
dryContact3StatusCurrent integer value of the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.7.1 |
dryContact3AlertCurrent alert status of the dry contact sensor connected to port 3. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 3.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.7.2 |
dryContact4 OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.8 |
dryContact4StatusCurrent integer value of the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.8.1 |
dryContact4AlertCurrent alert status of the dry contact sensor connected to port 4. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a dry contact sensor is connected to port 4.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.8.2 |
waterSensor OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.1.9 |
waterStatusCurrent integer value of the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. The value corresponds directly with the value displayed on the summary page and the status page for this sensor. This object is only applicable if a water sensor is connected.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.9.1 |
waterAlertCurrent alert status of the water sensor. A value of 0 indicates that the sensor has not been set to its alert condition, while a value of 1 indicates that it has. This object is only applicable if a water sensor is connected.ro Enumeration .1.3.6.1.4.1.3699.1.1.3.1.9.2 |
administration OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2 |
hostSystem OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.1 |
sysNameSystem node name. This value corresponds directly with the Node Name field on the General configuration page under the ADMINISTRATION menu.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.1.1 |
sysLocationSystem node location. his value corresponds directly with the Node Location field on the General configuration page under the ADMINISTRATION menu.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.1.2 |
sysIPSystem IP address. This value corresponds directly with the IP address assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.1.3 |
sysMaskSystem Subnet Mask. This value corresponds directly with the Subnet Mask assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.1.4 |
sysGatewaySystem Default Gateway. This value corresponds directly with the Default Gateway assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.1.5 |
sysDNSSystem DNS server. This value corresponds directly with the DNS server assigned to the enviromux-MINI on the Network configuration page under the ADMINISTRATION menu.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.1.6 |
temperatureSensor1Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.2 |
temperatureSensor1NameCurrent name assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.2.1 |
temperatureSensor1UnitTemperature units for the value of the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. The unit may either be Fahrenheit or Celsius, and corresponds directly with the unit chosen on the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1 or 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.2.2 |
temperatureSensor1LowThresholdLow threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.2.3 |
temperatureSensor1HighThresholdHigh threshold assigned to the temperature sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.2.4 |
temperatureSensor2Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.3 |
temperatureSensor2NameCurrent name assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.3.1 |
temperatureSensor2UnitTemperature units for the value of the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. The unit may either be Fahrenheit or Celsius, and corresponds directly with the unit chosen on the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 1 or 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.3.2 |
temperatureSensor2LowThresholdLow threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.3.3 |
temperatureSensor2HighThresholdHigh threshold assigned to the temperature sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a temperature sensor is connected to port 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.3.4 |
humiditySensor1Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.4 |
humiditySensor1NameCurrent name assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.4.1 |
humiditySensor1LowThresholdLow threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.4.2 |
humiditySensor1HighThresholdHigh threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.4.3 |
humiditySensor2Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.5 |
humiditySensor2NameCurrent name assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.5.1 |
humiditySensor2LowThresholdLow threshold assigned to the humidity sensor connected to port 2. This port is the left RJ-45 sensor port. This value corresponds directly with the low threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.5.2 |
humiditySensor2HighThresholdHigh threshold assigned to the humidity sensor connected to port 1. This port is the right RJ-45 sensor port. This value corresponds directly with the high threshold value entered in the configuration page for this sensor. This object is only applicable if a humidity sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.5.3 |
dryContact1Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.6 |
dryContact1NameCurrent name assigned to the dry contact sensor connected to port 1. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.6.1 |
dryContact1AlertStatusStatus which generates an alert condition for the dry contact sensor connected to port 1. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 1.rw Enumeration .1.3.6.1.4.1.3699.1.1.3.2.6.2 |
dryContact2Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.7 |
dryContact2NameCurrent name assigned to the dry contact sensor connected to port 2. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.7.1 |
dryContact2AlertStatusStatus which generates an alert condition for the dry contact sensor connected to port 2. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 2.rw Enumeration .1.3.6.1.4.1.3699.1.1.3.2.7.2 |
dryContact3Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.8 |
dryContact3NameCurrent name assigned to the dry contact sensor connected to port 3. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.8.1 |
dryContact3AlertStatusStatus which generates an alert condition for the dry contact sensor connected to port 3. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 3.rw Enumeration .1.3.6.1.4.1.3699.1.1.3.2.8.2 |
dryContact4Adm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.9 |
dryContact4NameCurrent name assigned to the dry contact sensor connected to port 4. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.9.1 |
dryContact4AlertStatusStatus which generates an alert condition for the dry contact sensor connected to port 4. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a dry contact sensor is connected to port 4.rw Enumeration .1.3.6.1.4.1.3699.1.1.3.2.9.2 |
waterSensorAdm OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.2.10 |
waterNameCurrent name assigned to the water sensor. This value corresponds directly with the name entered in the configuration page for this sensor. This object is only applicable if a water sensor is connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.2.10.1 |
waterAlertStatusStatus which generates an alert condition for the water sensor. A value of 0 represents OPEN, and a value of 1 represents CLOSED. This value corresponds directly with the Alert When value entered in the configuration page for this sensor. This object is only applicable if a water sensor is connected.rw Enumeration .1.3.6.1.4.1.3699.1.1.3.2.10.2 |
versionCode versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3699.1.1.3.3 |
envTraps OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.3.100 |
temperatureSensor1TrapTrap for alert from temperature sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.1 |
temperatureSensor2TrapTrap for alert from temperature sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.2 |
humiditySensor1TrapTrap for alert from humidity sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.3 |
humiditySensor2TrapTrap for alert from humidity sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.4 |
dryContactSensor1TrapTrap for alert from dry contact sensor connected to port 1. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.5 |
dryContactSensor2TrapTrap for alert from dry contact sensor connected to port 2. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.6 |
dryContactSensor3TrapTrap for alert from dry contact sensor connected to port 3. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.7 |
dryContactSensor4TrapTrap for alert from dry contact sensor connected to port 4. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.8 |
waterSensor1TrapTrap for alert from water sensor. Received if this sensor is configured to send SNMP traps using the Configuration page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.9 |
logTrapTrap generated when a log entry is created. Received if log entries are configured to be sent as SNMP traps using the Log Methods page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.100 |
overflowTrapTrap generated when has reached 90% capacity. Received if log overflow alerts are enabled and are configured to be sent as SNMP traps using the Log Overflow page, and SNMP is enabled on the Network configuration page under the ADMINISTRATION menu. NOTIFICATION-TYPE .1.3.6.1.4.1.3699.1.1.3.100.101 |
otherProduct OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.1.200 |
software OBJECT IDENTIFIER .1.3.6.1.4.1.3699.1.2 |
experimental OBJECT IDENTIFIER .1.3.6.1.4.1.3699.2 |