NBS-SYSCOMM-MIB
Information Base for provisioning ip configuration of managed device.
Main OID:
nbsSyscommMib.1.3.6.1.4.1.629.214
16
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
16 total| Object Name |
|---|
nbsSyscommMibInformation Base for provisioning ip configuration of managed device. MODULE-IDENTITY .1.3.6.1.4.1.629.214 |
nbsSyscommInetGrpTCP/IP configuration of system management card OBJECT IDENTIFIER .1.3.6.1.4.1.629.214.3 |
nbsSyscommInetSlaacAddrThe IPv6 link-local address assigned by the Stateless Address Autoconfiguration process.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.3 |
nbsSyscommInetSlaacAddrPrefixThe prefix length of nbsSyscommInetSlaacAddr.ro InetAddressPrefixLength (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.5 |
nbsSyscommInetAddrAdminPersistent. User-desired IPv6 address. For IPv4, use the object nbsCmmcSysIpAddr[Admin]rw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.10 |
nbsSyscommInetAddrOperThe user-specified Ipv6 address actually in effect. For IPv4, please refer to the object nbsCmmcSysIpAddrOper.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.11 |
nbsSyscommInetAddrPrefixAdminThe prefix length of nbsSyscommInetAddrAdmin.rw InetAddressPrefixLength (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.22 |
nbsSyscommInetAddrPrefixOperThe prefix length of nbsSyscommInetAddrOper.ro InetAddressPrefixLength (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.23 |
nbsSyscommGateAddrAdminPersistent. Desired default IPv6 gateway. For IPv4, use the object nbsCmmcSysDefaultGateway[Admin].rw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.30 |
nbsSyscommGateAddrOperThe current IPv6 default gateway. For IPv4, please refer to nbsCmmcSysDefaultGatewayOper.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.3.31 |
nbsSyscommEventGrpObjects to be included in event notifications OBJECT IDENTIFIER .1.3.6.1.4.1.629.214.100 |
nbsSyscommEventsEvents related to system communications OBJECT IDENTIFIER .1.3.6.1.4.1.629.214.100.0 |
nbsSyscommInetCfgChangingSent when before the changes are actually applied. This is a warning to all SNMP Manager stations that the IP Address is changing, and they will soon lose contact with this device. This Notification's nbsCmmcSysTrapTblEntLevel is fatal(2). NOTIFICATION-TYPE .1.3.6.1.4.1.629.214.100.0.30 |
nbsSyscommInetCfgChangedSent after changes are complete and have been applied. This Notification's nbsCmmcSysTrapTblEntLevel is fatal(2). NOTIFICATION-TYPE .1.3.6.1.4.1.629.214.100.0.31 |
nbsSyscommInetAddrPriorThe value nbsSyscommInetAddrOper had before the last modificationro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.100.311 |
nbsSyscommGateAddrPriorThe value nbsSyscommGateAddrOper had before the last modificationro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.629.214.100.331 |