NBS-REDUNDANCY-MIB
The NBS-REDUNDANCY-MIB module enables the monitoring and configuration of high-availability redundancy protocols and state synchronization mechanisms within NBS network devices. It exposes specific metrics for failover status, active/standby pair health, and redundancy group operational states to ensure continuous service availability.
Imported Objects
Objects
31 total| Object Name |
|---|
nbsRedundancyMibInformation Base for redundancy settings. MODULE-IDENTITY .1.3.6.1.4.1.629.221 |
nbsRedundCfgGrpRedundancy settings OBJECT IDENTIFIER .1.3.6.1.4.1.629.221.1 |
nbsRedundCfgTableSizeThe number of entries in nbsRedundCfgTable.ro INTEGER .1.3.6.1.4.1.629.221.1.1 |
nbsRedundCfgTableThis table lists all ports that can be redundant group members. SEQUENCE OF NbsRedundCfgEntry .1.3.6.1.4.1.629.221.1.2 |
nbsRedundCfgEntryRedundancy status of a port. NbsRedundCfgEntry .1.3.6.1.4.1.629.221.1.2.1 |
nbsRedundCfgNdxUnique index of a redundant port. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.629.221.1.2.1.1 |
nbsRedundCfgPartnerNdxAdminAdministratively desired InterfaceIndex of the other port in this port's redundant pair.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.629.221.1.2.1.2 |
nbsRedundCfgPartnerNdxOperCurrent operational InterfaceIndex of the other port in this port's redundant pair.ro InterfaceIndex (IF-MIB) .1.3.6.1.4.1.629.221.1.2.1.3 |
nbsRedundCfgStatusAdminImpulse. Used to trigger an immediate switchover. Equivalent (aliased) to nbsCmmcPortSelectLink.rw Enumeration .1.3.6.1.4.1.629.221.1.2.1.10 |
nbsRedundCfgStatusOperActual redundancy status of this port.ro Enumeration .1.3.6.1.4.1.629.221.1.2.1.11 |
nbsRedundCfgPreferredAdminPersistent. Used to optionally indicate one port in a redundant pair should always be active if it has ifOperStatus up(1). Equivalent/aliased to nbsCmmcPortPreferred. Setting one port to preferActive(3) forces its redundant partner to preferNot(2). Setting a port to preferNot(2) has no effect on its redundant partner.rw Enumeration .1.3.6.1.4.1.629.221.1.2.1.20 |
nbsRedundCfgStandbyTxAdminPersistent. Desired transmitter state for this port when it is in standby. Equivalent/aliased to nbsCmmcPortRedundantTxMode. If this cannot be selected by the user, this should be notSupported(1). For 1+1 redundancy, use standbyHot(3). For 1:1 redundancy, use standbyCold(2).rw Enumeration .1.3.6.1.4.1.629.221.1.2.1.30 |
nbsRedundCfgStandbyTxTogglePersistent. Setting this to txToggle(3) allows a formerly active port that detects no signal to notify its remote partner that it is ready to transmit and connectivity is re-established between them. Enabling this feature may result in unnecessary switchovers and dropped traffic.rw Enumeration .1.3.6.1.4.1.629.221.1.2.1.40 |
nbsRedundCfgIfTypeAdminThis port's administratively desired typerw Enumeration .1.3.6.1.4.1.629.221.1.2.1.50 |
nbsRedundCfgIfTypeOperThis port's current operational typero Enumeration .1.3.6.1.4.1.629.221.1.2.1.51 |
nbsRedundCfgGroupNumberAdminThis port's administratively desired group.rw INTEGER .1.3.6.1.4.1.629.221.1.2.1.60 |
nbsRedundCfgGroupNumberOperThis port's current operational group.ro INTEGER .1.3.6.1.4.1.629.221.1.2.1.61 |
nbsRedundGroupCfgTableSizeThe number of entries in nbsRedundGroupCfgTable.ro INTEGER .1.3.6.1.4.1.629.221.1.3 |
nbsRedundGroupCfgTableThis table lists all ports in a redundant pair. SEQUENCE OF NbsRedundGroupCfgEntry .1.3.6.1.4.1.629.221.1.4 |
nbsRedundGroupCfgEntryRedundancy status of a port. NbsRedundGroupCfgEntry .1.3.6.1.4.1.629.221.1.4.1 |
nbsRedundGroupCfgNdxUnique index of a slot. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.629.221.1.4.1.1 |
nbsRedundGroupCfgNumberUnique index of a slot's group number. INTEGER .1.3.6.1.4.1.629.221.1.4.1.2 |
nbsRedundGroupCfgOperThis bitmask indicates this group's current operational port membership. Bit 0 is reserved.ro OCTET STRING .1.3.6.1.4.1.629.221.1.4.1.13 |
nbsRedundGroupCfgModeAdminThis group's administratively desired mode. For modeA, when a faulty condition occurs on one member, all the members in the group will take the same action concurrently. For modeB, only the faulty member will take action.rw Enumeration .1.3.6.1.4.1.629.221.1.4.1.15 |
nbsRedundGroupCfgModeOperThis group's current operational modero Enumeration .1.3.6.1.4.1.629.221.1.4.1.16 |
nbsRedundGroupCfgYcableAdminThis object is used to enable and disable Y-Cable redundancy on a group.rw Enumeration .1.3.6.1.4.1.629.221.1.4.1.20 |
nbsRedundGroupCfgYcableOperThis Ycable group's current operational status.ro Enumeration .1.3.6.1.4.1.629.221.1.4.1.21 |
nbsRedundGroupCfgRowStatusThis table RowStatus object to create, modify and delete the rowsrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.629.221.1.4.1.50 |
nbsRedundEventGrpRedundancy-related events OBJECT IDENTIFIER .1.3.6.1.4.1.629.221.100 |
nbsYcableTrapsY-cable Traps or Notifications OBJECT IDENTIFIER .1.3.6.1.4.1.629.221.100.0 |
nbsYcableTrapsStatusChangedSent when the nbsRedundCfgStatusOper of a port changes. This Notification should be of Severity INFO. NOTIFICATION-TYPE .1.3.6.1.4.1.629.221.100.0.10 |
More MIBs from Nbase
Browse all NbaseMIBs →SNMP MIB module
The NBS-COHERENT-MIB module enables monitoring of Coherent CFP (Common Form Factor Pluggable) optical transceiver parameters, including optical power levels, temperature, bias current, and voltage, on network interface cards supporting the Coherent CFP form factor.
Standard SNMP MIB module defining data structures for RT-CFG-MIB.
Standard SNMP MIB module defining data structures for NBASE-G1-MIB.
SNMP MIB module
The NBS-SLA-MIB module enables the monitoring and management of Service Level Agreement (SLA) performance metrics, such as latency, jitter, packet loss, and availability, for network services within NBS (Nortel Broadband Services) infrastructure. It facilitates the collection of SLA violation data and compliance status to support automated quality-of-service assurance and reporting.