Home/Catalog/NATEKS-MIB

NATEKS-MIB

AI MIB Summary

The NATEKS-MIB module facilitates monitoring and management of NATEKS network devices, specifically providing access to statistical counters and enabling the reset of accumulated traffic or session metrics via the `statReset` object within the stats branch.

Added statReset to stats branch
Main OID:
nateks.1.3.6.1.4.1.4249
271
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

271 total
Object Name
nateksAdded statReset to stats branch
MODULE-IDENTITY
.1.3.6.1.4.1.4249
nateksTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.0
tlmStatusChangeA tlmStatusChange trap is sent when the value of an instance tlmStatus changes. It can be utilized by an NMS to trigger polls.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4249.0.1
alarmValueChangeA alarmValueChange trap is sent when alarm value changes. It can be utilized by an NMS to trigger polls.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4249.0.2
tftpStatusChangeThis trap is sent during the process of SNMP-initiated TFTP maintenance command (TFTP software download or configuration up/download) to report current execution status. In this case tftpLastOp shows the current operation, tftpLastOpTime indicates starting time of current operation, tftpTransferStatus indicates status of the transfer. If the command is denied, this trap is also sent with tftpTransferStatus value of busyByOther. In this case tftpLastOp indicates the operation that conflicted with the command.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4249.0.3
macFilterViolationThis trap is sent to indicate that MAC filter access violation has happened and specific security action will be performed. Variables: macFilterViolationsIfIndex, ifDescr - index and name of interface; macFilterViolationsMAC - violating MAC; macFilterConfigAction - action to be performed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4249.0.4
dInStateChangeThis trap is sent to indicate that input state has changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4249.0.5
dOutStateChangeThis trap is sent to indicate that output state has changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4249.0.6
nateksProducts
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1
megatrans3CLTU
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.1
orion2LTU
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.7
megatrans3CRGN
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.8
megatrans4LTU
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.11
megatrans4RGN
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.12
orion3LTU
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.22
orion3NTU
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.23
orion3repeater
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.24
miniFlex
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.1.26
nateksMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2
systemAlarmDevice alarm statero
Enumeration
.1.3.6.1.4.1.4249.2.1
systemResetWriting reset(1) to maintReset perform a restart of the device. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.2
common
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.3
modelModel name, for example MGS-3C-RGN. It is mandatory that this only contain printable ASCII characters.ro
DisplayString
.1.3.6.1.4.1.4249.2.3.1
idDevice ID, displayed in the main menu of the module. It is mandatory that this only contain printable ASCII characters.rw
DisplayString
.1.3.6.1.4.1.4249.2.3.2
hardwareVersionVersion of the device's hardware. For examle: 1.0ro
DisplayString
.1.3.6.1.4.1.4249.2.3.3
softwareVersionVersion of the device's main software and, optionally, versions of firmware loaded in DSL chipsets, etc. (if present). For examle: 3.5.0.5.9/5.0ro
DisplayString
.1.3.6.1.4.1.4249.2.3.4
softwareDateBuild date of the device's main software in MM.DD.YYYY format. Empty string, if build date is not maintained by devices software.ro
DisplayString
.1.3.6.1.4.1.4249.2.3.5
moduleTypeModule typero
Enumeration
.1.3.6.1.4.1.4249.2.3.6
subrackAddressAddress of the module in the FlexGain cassette. For modules that do not have such an address, a value of 0 is returned.ro
Integer32
.1.3.6.1.4.1.4249.2.3.7
errorCodeDevice-dependent error code. Normal value for errorCode is 0, i.e. device is fully operational. Any non-zero value indicates device hardware fault to management software.ro
Integer32
.1.3.6.1.4.1.4249.2.3.8
serialNumberDevice serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.3.9
config
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.4
configRWReading configRW results in reading the whole running config (as DUMP R in Megatrans 3C does). Writing configRW results in writing to startup config (as LOAD in Megatrans 3C does). This variable may be also used by devices, that do not maintain configValueTable and configGroupTable, to get/set their configuration.rw
OCTET STRING
.1.3.6.1.4.1.4249.2.4.1
configDefaultWriting integer value to configDefault applies default profile to the configuration. Values and contents of default profiles are device-dependent.rw
IntegerNumber
.1.3.6.1.4.1.4249.2.4.2
configSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.4.100
configNumberValuesNumber of configuration values in device's configuration.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.4.100.1
configValueTableA list of configuration values. The number of entries is given by the value of configSize.
SEQUENCE OF ConfigValueEntry
.1.3.6.1.4.1.4249.2.4.100.2
configValueEntryConfiguration item.
ConfigValueEntry
.1.3.6.1.4.1.4249.2.4.100.2.1
valueIdA unique index of configuration value. It is constant at least until main software of the module changes.
IntegerIndex
.1.3.6.1.4.1.4249.2.4.100.2.1.1
valueGroupIndex of values' configuration group in the configGroupTable.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.4.100.2.1.2
valueNameA unique name of configuration value. It is constant at least until main software of the module changes. Usually, it remains constant through the lifecycle of the product.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.4.100.2.1.3
valueGroupNameName of values' configuration group.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.4.100.2.1.4
valueTypeValue type.ro
Enumeration
.1.3.6.1.4.1.4249.2.4.100.2.1.5
valueStatusChange status for a value. All values of valueType setNow(1) have unchanged(1) status. Status for values of valueType applyConfirm(2): Initially, all values have unchanged(1) status. When value is changed in new configuration, valueStatus is changed(2). When APPLY is made in respect of a value, valueStatus is applied(3). When CONFIRM is made for a value, valueStatus returns to unchanged(1). Status for values of type afterReset: If valueStartup is different from valueRunning, valueStatus is changed(2), otherwise unchanged(1).ro
Enumeration
.1.3.6.1.4.1.4249.2.4.100.2.1.6
valueStartupStartup value of configuration variable. Write operation changes valueStartup for values of valueType afterReset(3), valueRunning for values of valueType setNow(1), valueNew for values of valueType applyConfirm(2).rw
OCTET STRING
.1.3.6.1.4.1.4249.2.4.100.2.1.7
valueRunningRunning value of configuration variable. Write operation changes valueStartup for values of valueType afterReset(3), valueRunning for values of valueType setNow(1), valueNew for values of valueType applyConfirm(2).rw
OCTET STRING
.1.3.6.1.4.1.4249.2.4.100.2.1.8
valueNewNew value of configuration variable. Write operation changes valueStartup for values of valueType afterReset(3), valueRunning for values of valueType setNow(1), valueNew for values of valueType applyConfirm(2).rw
OCTET STRING
.1.3.6.1.4.1.4249.2.4.100.2.1.9
valueBackupBackup value of configuration variable.ro
OCTET STRING
.1.3.6.1.4.1.4249.2.4.100.2.1.10
configNumberGroupsNumber of configuration groups in device's configuration.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.4.100.3
configGroupTableA list of configuration values. The number of entries is given by the value of configSize.
SEQUENCE OF ConfigGroupEntry
.1.3.6.1.4.1.4249.2.4.100.4
configGroupEntryConfiguration group.
ConfigGroupEntry
.1.3.6.1.4.1.4249.2.4.100.4.1
groupIdA unique index of configuration group. It is constant at least until main software of the module changes.
IntegerIndex
.1.3.6.1.4.1.4249.2.4.100.4.1.1
groupNameName of configuration group. It is constant at least until main software of the module changes. Usually, it remains constant through the lifecycle of the product.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.4.100.4.1.2
groupTypeGroup type.ro
Enumeration
.1.3.6.1.4.1.4249.2.4.100.4.1.3
groupStatusChange status for a groupvalue. All groups of groupType setNow(1) have unchanged(1) status. Status for groups of groupType applyConfirm(2): Initially, all values have unchanged(1) status. When some of group values are changed in new configuration, groupStatus is changed(2). When APPLY is made for a group, groupStatus is applied(3). When CONFIRM is made for a group, groupStatus returns to unchanged(1). Status for groups of type afterReset: If startup values in the group are different from running values, groupStatus is changed(2), otherwise unchanged(1). Writing applied(3) to the groupStatus makes APPLY operation on a group. APPLY operation is allowed only for groups of groupType applyConfirm(2). Other write operations should report error.rw
Enumeration
.1.3.6.1.4.1.4249.2.4.100.4.1.4
configApplyAllWriting applyAll(1) to configApplyAll makes APPLY ALL operation. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.4.100.5
configConfirmWriting confirm(1) to configConfirm makes CONFIRM operation. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.4.100.6
configBackupWriting backup(1) to configBackup performs BACKUP operation. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.4.100.7
configRestoreWriting restore(1) to configRestore performs RESTORE operation. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.4.100.8
stats
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5
g826
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.1
g826NumberNumber of g826 statistics.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.1.1
g826TableA list of g826 statistics. Each consists of an interface index in interfaces table, statistics name and g826 statistics valuess.deprecated
SEQUENCE OF G826Entry
.1.3.6.1.4.1.4249.2.5.1.2
g826EntryG826 statistics.deprecated
G826Entry
.1.3.6.1.4.1.4249.2.5.1.2.1
g826IdA unique index of this g826 statistics. It is constant at least between device reboots.deprecated
IntegerIndex
.1.3.6.1.4.1.4249.2.5.1.2.1.1
g826IfIndexIndex of interface in interfaces table, this g826 statistics is for.rodeprecated
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.4249.2.5.1.2.1.2
g826NameName of the statistic, for example: E1-1-CRC4, E1-2-E-Bit.rodeprecated
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.1.2.1.3
g826EBNumber of errored blocks.rodeprecated
Gauge32
.1.3.6.1.4.1.4249.2.5.1.2.1.4
g826ESNumber of errored seconds.rodeprecated
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.2.1.5
g826SESNumber of severely errored seconds.rodeprecated
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.2.1.6
g826BBENumber of background block errors.rodeprecated
Gauge32
.1.3.6.1.4.1.4249.2.5.1.2.1.7
g826AvailableTimeAvailable time in seconds.rodeprecated
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.2.1.8
g826UnavailableTimeUnavailable time in seconds.rodeprecated
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.2.1.9
g826StatResetWriting reset(1) to g826StatReset restarts this g826 statistic. Read always returns readValue(2).rwdeprecated
Enumeration
.1.3.6.1.4.1.4249.2.5.1.2.1.10
g826ResetWriting reset(1) to g826Reset restarts all g826 statistics. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.5.1.3
ifG826TableA list of g826 statistics. Each consists of an interface index in interfaces table, statistics name and g826 statistics valuess.
SEQUENCE OF IfG826Entry
.1.3.6.1.4.1.4249.2.5.1.4
ifG826EntryG826 statistics grouped by interface.
IfG826Entry
.1.3.6.1.4.1.4249.2.5.1.4.1
ifG826IdA unique index of this g826 statistics. It is constant at least between device reboots.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.1.4.1.1
ifG826IfIndexIndex of interface in interfaces table, this g826 statistics is for.
InterfaceIndex
.1.3.6.1.4.1.4249.2.5.1.4.1.2
ifG826NameName of the statistic, for example: E1-1-CRC4, E1-2-E-Bit.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.1.4.1.3
ifG826EBNumber of errored blocks.ro
Gauge32
.1.3.6.1.4.1.4249.2.5.1.4.1.4
ifG826ESNumber of errored seconds.ro
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.4.1.5
ifG826SESNumber of severely errored seconds.ro
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.4.1.6
ifG826BBENumber of background block errors.ro
Gauge32
.1.3.6.1.4.1.4249.2.5.1.4.1.7
ifG826AvailableTimeAvailable time in seconds.ro
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.4.1.8
ifG826UnavailableTimeUnavailable time in seconds.ro
Gauge32 UNITS "s"
.1.3.6.1.4.1.4249.2.5.1.4.1.9
ifG826StatResetWriting reset(1) to ifG826StatReset restarts this g826 statistic. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.5.1.4.1.10
alarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.2
alarmNumberNumber of alarms.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.2.1
alarmTableA list of alarms. Each consists of an interface index in interfaces table, alarm name, value and cutoff information.
SEQUENCE OF AlarmEntry
.1.3.6.1.4.1.4249.2.5.2.2
alarmEntryAlarms.
AlarmEntry
.1.3.6.1.4.1.4249.2.5.2.2.1
alarmIdA unique index of alarm. It is constant at least between device reboots.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.2.2.1.1
alarmIfIndexIndex of interface in interfaces table, which state this alarm indicates. Alarms, that do not have associated interfaces (for example, maintenance alarms), should have index of management interface as alarmIfIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.4249.2.5.2.2.1.2
alarmNameName of the alarm, for example: LOS-S, BER-H.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.2.2.1.3
alarmValueAlarm status.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.2.2.1.4
alarmCutoffAlarm cutoff status.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.2.2.1.5
alarmTypeAlarm type. If none of alarm types is applicable to this alarm, all bits are zero.ro
Bits
.1.3.6.1.4.1.4249.2.5.2.2.1.6
alarmDisplayTypeSimplified alarm type to be used in trap filtersro
Enumeration
.1.3.6.1.4.1.4249.2.5.2.2.1.7
alarmTrapEnableAlarm trap generation setup: changes in alarm state will cause trap generation when the alarmTrapEnable is true.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.2.3
ifAlarmTableA two-dimentional array of alarms. Alarms are grouped by interface number.
SEQUENCE OF IfAlarmEntry
.1.3.6.1.4.1.4249.2.5.2.4
ifAlarmEntryAlarms grouped by interface.
IfAlarmEntry
.1.3.6.1.4.1.4249.2.5.2.4.1
ifAlarmIdA unique index of alarm within interface. It is constant at least between device reboots.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.2.4.1.1
ifAlarmIfIndexIndex of interface in interfaces table, which state this alarm indicates. Alarms, that do not have associated interfaces (for example, maintenance alarms), should have index of management interface as alarmIfIndex.ro
InterfaceIndex
.1.3.6.1.4.1.4249.2.5.2.4.1.2
ifAlarmNameName of the alarm, for example: LOS-S, BER-H.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.2.4.1.3
ifAlarmValueAlarm status.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.2.4.1.4
ifAlarmCutoffAlarm cutoff status.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.2.4.1.5
ifAlarmTypeAlarm type. If none of alarm types is applicable to this alarm, all bits are zero.ro
Bits
.1.3.6.1.4.1.4249.2.5.2.4.1.6
ifAlarmDisplayTypeSimplified alarm type to be used in trap filtersro
Enumeration
.1.3.6.1.4.1.4249.2.5.2.4.1.7
tlm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.3
tlmNumberNumber of tlm contacts.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.3.1
tlmTableA list of tlms. Each consists of tlm name, setup and status information, and trap generation setup.
SEQUENCE OF TlmEntry
.1.3.6.1.4.1.4249.2.5.3.2
tlmEntryTLM
TlmEntry
.1.3.6.1.4.1.4249.2.5.3.2.1
tlmIdA unique index of TLM. It is constant at least between device reboots.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.3.2.1.1
tlmNameName of the TLM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.3.2.1.2
tlmStatusThe status of the TLM: on, off or detected.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.3.2.1.3
tlmLastStatusChangeThe time of last TLM status change, counted from system start.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.4249.2.5.3.2.1.4
tlmSetupTLM setup: normally open or normally closed. Writing to this variable will configure this TLM, if the device does support the write access to this variable.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.3.2.1.5
tlmTrapEnableTLM trap generation setup: changes in TLM status will cause trap generation when the tlmTrapEnable is true.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.3.2.1.6
tlmClearWriting reset(1) to tlmClear will clear the TLM history, and det state of all TLM indicators will become off state. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.5.3.3
dsl
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.4
dslChannelNumberNumber of dsl channels.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.4.1
dslUnitTypeThe type of the unit: line termination units (LTU) and network termination units (NTU) will have the modem(1) value. All types of regenerators have regenerator(2) value.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.2
dslChannelTableA list of DSL channels present on this device. Each consists of DSL index, ifIndex, setup and status information.
SEQUENCE OF DslChannelEntry
.1.3.6.1.4.1.4249.2.5.4.3
dslChannelEntryDSL channel
DslChannelEntry
.1.3.6.1.4.1.4249.2.5.4.3.1
dslChannelIdA unique index of the DSL channel. It is constant for a given model.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.3.1.1
dslChannelIfIndexIndex in interfaces table of this DSL channel.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.4249.2.5.4.3.1.2
dslChannelModeThe activation mode of this channel: either it is Master (xU-C) or Slave (xU-R).ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.3
dslChannelStandardThe G.Shdsl mode this channel is working in.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.4
dslChannelClockReferenceThe G.Shdsl clock mode this channel is working in.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.5
dslChannelLineCodeConfigThe configured line code of this channel.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.6
dslChannelPSDConfigThe configured PSD mask (annex) of this channel.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.7
dslChannelBaserateConfigThe configured base data rate (in 64kbit/s units) of this channel. 0 means auto.ro
Integer32
.1.3.6.1.4.1.4249.2.5.4.3.1.8
dslChannelStatusThe activation status of this DSL channel.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.9
dslChannelLineCodeCurrent working line code of this channel. If the link is down, this item has notAvailable(0) value.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.10
dslChannelPSDCurrent working PSD mask (annex) of this channel. If the link is down, this item has notAvailable(0) value.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.11
dslChannelBaserateCurrent working base data rate (in 64kbit/s units) of this channel. If the link is down, this item has 0 value.ro
Integer32
.1.3.6.1.4.1.4249.2.5.4.3.1.12
dslChannelLineRateCurrent working line rate in kbit/s of this channel. If the link is down, this item has 0 value.ro
Integer32
.1.3.6.1.4.1.4249.2.5.4.3.1.13
dslChannelPayloadRateCurrent working payload rate in kbit/s of this channel. If the link is down, this item has 0 value.ro
Integer32
.1.3.6.1.4.1.4249.2.5.4.3.1.14
dslChannelNMRCurrent noise margin rate for the DSL channel in dB.ro
Integer32 UNITS "dB"
.1.3.6.1.4.1.4249.2.5.4.3.1.15
dslChannelPowerBackoffCurrent power backoff of the local side of the DSL channel in dB.ro
Integer32 UNITS "dB"
.1.3.6.1.4.1.4249.2.5.4.3.1.16
dslChannelFarEndPowerBackoffCurrent far end power backoff of the DSL channel in dB.ro
Integer32 UNITS "dB"
.1.3.6.1.4.1.4249.2.5.4.3.1.17
dslChannelLoopAttenuationCurrent loop attenuation of the DSL channel in dB.ro
Integer32 UNITS "dB"
.1.3.6.1.4.1.4249.2.5.4.3.1.18
dslChannelEOCNumberThe EOC number of the unit in this DSL link. xtuC 1 xtuR 2 repeater N=1..max N+2ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.3.1.19
dslChannelRegeneratorNumberThe number of regenerators in the link. This unit is not present on regenerators.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.4.3.1.20
dslChannelRemotePowerThe remote power status of the channel. This item is not present on regenerators. On devices without remote powering capability it is present and always shows off(2). on(1) means the remote power is turned on in configuration and remote power in turned on. off(2) means the remote power is turned off in configuration or remote power capability is not present in the device. alarm(3) means remote power is turned off for a certain amount of time because overcurrent protection has triggered or AC/DC leakage threshold was met.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.3.1.21
dslChannelRemotePowerVoltageRemote power voltage configuration for the channel. This item is not present on regenerators. On devices without remote powering capability it is present and always shows 0. If remote power is turned off for this channel in configuration, 0 is read from this item. If remote power is turned on for this channel in configuration, remote power nominal voltage is read from this item regardless of error status (it may be off due to overcurrent etc). This item appeared in MIB v0.9 and some devices may not support it.ro
Integer32
.1.3.6.1.4.1.4249.2.5.4.3.1.22
dslGroupNumberThe number of multiwire groups.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.4.4
dslGroupTableThis table contains information on multipair and 4-wire goups of DSL channels.
SEQUENCE OF DslGroupEntry
.1.3.6.1.4.1.4249.2.5.4.5
dslGroupEntryDSL multipair of 4-wire group
DslGroupEntry
.1.3.6.1.4.1.4249.2.5.4.5.1
dslGroupIdA unique index of the DSL channel group. It is constant between changes of unit configuration.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.5.1.1
dslGroupTypeThe type of channel grouping. type4wire(1) represent 4-wire method of channel aggregation. type2pair(2)-type4pair(4) represent the M-pair method of channel aggregation.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.4.5.1.2
dslGroupMainChannelThis is the dslChannelId of the main channel in the multipair or 4-wire group. The configuration for all channels in the group is taken from the main channel. Only the main channel is mentioned in regenerator pairs when regenerator is working in multipair mode.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.5.1.3
dslGroupChannel1The first channel in the sequence of dslChannelId's of the channels in the multipair or 4-wire group. The main channel is mentioned amongst others.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.5.1.4
dslGroupChannel2The second channel in the sequence of dslChannelId's of the channels in the multipair or 4-wire group. The main channel is mentioned amongst others.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.5.1.5
dslGroupChannel3The third channel in the sequence of dslChannelId's of the channels in the multipair or 4-wire group. The main channel is mentioned amongst others. Only present for 3-pair and 4-pair groups.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.5.1.6
dslGroupChannel4The fourth channel in the sequence of dslChannelId's of the channels in the multipair or 4-wire group. The main channel is mentioned amongst others. Only present for 4-pair groups.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.5.1.7
dslRegenerationChannelsThe number of regenerator channels working in this device.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.4.6
dslRegenerationTableThis table is a list of regenerator channels working in this device. Devices that do not have regenerator functions do not need to implement this table.
SEQUENCE OF DslRegenerationEntry
.1.3.6.1.4.1.4249.2.5.4.7
dslRegenerationEntryRegeneration channel
DslRegenerationEntry
.1.3.6.1.4.1.4249.2.5.4.7.1
dslRegenerationIdA unique index of the DSL regeneration channel. It is constant between configuration changes.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.7.1.1
dslRegenerationSide1This is the dslChannelId of side 1 of the regeneration channel.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.7.1.2
dslRegenerationSide2This is the dslChannelId of side 2 of the regeneration channel.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.5.4.7.1.3
indication
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.5
indicationLedNumberNumber of LED indicators the device has.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.5.1
indicationLedTableA list LED indicators. Each consists of an LED index, textual description, populated/not populated status, current color and blinking rate.
SEQUENCE OF IndicationLedEntry
.1.3.6.1.4.1.4249.2.5.5.2
indicationLedEntryLED inidicators.
IndicationLedEntry
.1.3.6.1.4.1.4249.2.5.5.2.1
indicationLedIdA unique index of the LED indicator. It is constant between different models of one device family.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.5.2.1.1
indicationLedDescriptionDescription of LED indicator. May include name on the front/back panel of the device and/or place of the LED.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.5.2.1.2
indicationLedStateThe state of a LED. If the LED is not present, it's state is not-populated. If it is not lit, it's state is OFF. If it is lit, then a color is reported.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.5.2.1.3
indicationLedFlashIf the LED is switching on and off at a constant rate, shows how is it blinking. Values from 1 to 14 represent a bit mask, where each bit shows, if the LED is lit during corresponding quarter of second: bit 0 - first quarter, bit 1 - second etc. If the LED is lit constantly, returns 'constant(15)'.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.5.2.1.4
temperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.6
temperatureSensorNumberNumber of the temperature sensors the device has.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.6.1
temperatureSensorTableA list temperature sensors. First sensor in the list should always be the sensor that can be considered as 'Board temperature' sensor. For each sensor there is an identifier, description and the temperature value in 1/1000 of the Celcium degree.
SEQUENCE OF TemperatureSensorEntry
.1.3.6.1.4.1.4249.2.5.6.2
temperatureSensorEntryTemperature sensors.
TemperatureSensorEntry
.1.3.6.1.4.1.4249.2.5.6.2.1
temperatureSensorIdA unique index of the temperature sensor. It is constant between different models of one device family.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.6.2.1.1
temperatureSensorDescriptionDescription of the temperature sensor. Should describe, where temperature is measured.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.6.2.1.2
temperatureSensorValueThe temperature value in 1/1000 of the Celcium degree. For example, 25000 = 25C, -10500 = -10.5C.ro
IntegerMillis UNITS "C"
.1.3.6.1.4.1.4249.2.5.6.2.1.3
time
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.7
timeSourceNumberNumber of device's UTC time sources.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.7.1
timeSourceTableTable of UTC time sources present on device. Examples are UTC, satellite (GNSS) etc.
SEQUENCE OF TimeSourceEntry
.1.3.6.1.4.1.4249.2.5.7.2
timeSourceEntryTime source.
TimeSourceEntry
.1.3.6.1.4.1.4249.2.5.7.2.1
timeSourceIdA unique index of the time source. It is constant between reconfigurations of a device.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.7.2.1.1
timeSourceNameName of the time source. For example: NTP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.7.2.1.2
timeSourceStratumClock source stratum as it is defined in NTP.ro
Integer32
.1.3.6.1.4.1.4249.2.5.7.2.1.3
timeSourceValueUTC time as reported by this source. If source is not ready (no connection to server or no signal), zero-length octet string is returned.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.7.2.1.4
timeZoneDisplacement, in minutes, of local time relative to UTC. For example, 240 is UTC+04:00 (Moscow Time), -480 is UTC-08:00 (Pacific Standard Time).rw
Integer32 (-1440..1440)
.1.3.6.1.4.1.4249.2.5.7.3
localPower
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.8
powerSourceNumberNumber of device's local power sources.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.8.1
powerSourceTableTable of local power sources available to the device, listed in priority order.
SEQUENCE OF PowerSourceEntry
.1.3.6.1.4.1.4249.2.5.8.2
powerSourceEntryPower source.
PowerSourceEntry
.1.3.6.1.4.1.4249.2.5.8.2.1
powerSourceIdA unique index of the power source.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.8.2.1.1
powerSourceNameName of the power source. For example: 48V-a.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.8.2.1.2
powerSourceNominalVoltageNominal voltage of the power source.ro
Integer32 UNITS "V"
.1.3.6.1.4.1.4249.2.5.8.2.1.3
powerSourceStatusAvailability status of this power source.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.8.2.1.4
sfpDDM
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.9
sfpDDMNumberNumber of the sfp modules the device has.ro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.9.1
sfpDDMTableTable of DDM values read from SFP
SEQUENCE OF SfpDDMEntry
.1.3.6.1.4.1.4249.2.5.9.2
sfpDDMEntrySFP Digital diagnostics monitoring
SfpDDMEntry
.1.3.6.1.4.1.4249.2.5.9.2.1
sfpDDMIdAn Index of DDM value
IntegerIndex
.1.3.6.1.4.1.4249.2.5.9.2.1.1
sfpDDMTemperatureInternally measured transceiver temperature in range from -128C to +128C.ro
IntegerMillis(-128000..128000) UNITS "C"
.1.3.6.1.4.1.4249.2.5.9.2.1.2
sfpDDMSupplyVoltageInternally measured transceiver supply voltage in range from 0 to +6.5535 Volts.ro
IntegerMillis
.1.3.6.1.4.1.4249.2.5.9.2.1.3
sfpDDMTxBiasCurrentMeasured TX bias current in range from 0 to 131.0 mAro
IntegerWithDecimal
.1.3.6.1.4.1.4249.2.5.9.2.1.4
sfpDDMTxOutputmWMeasured TX output power in range from 0 to 6.5535 mWro
SfpPowerMilliWatt
.1.3.6.1.4.1.4249.2.5.9.2.1.5
sfpDDMTxOutputdBmMeasured TX output power in range from -40 to +8.2 dBmro
IntegerWithDecimal(-400..82) UNITS "dBm"
.1.3.6.1.4.1.4249.2.5.9.2.1.6
sfpDDMRxInputmWMeasured RX received optical power from 0 to 6.5535 mW.ro
SfpPowerMilliWatt
.1.3.6.1.4.1.4249.2.5.9.2.1.7
sfpDDMRxInputdBmMeasured RX received optical power from -40 to +8.2 dBm.ro
IntegerWithDecimal(-400..82) UNITS "dBm"
.1.3.6.1.4.1.4249.2.5.9.2.1.8
sfpDDMMediaTypeThis object returns sfpMedia type. when module is not mounted return value is unknown (3)ro
Enumeration
.1.3.6.1.4.1.4249.2.5.9.2.1.9
sfpDDMPresenceThis object indicates if specified SFP interface plugged or not present (1) indicates that SFP interface is plugged. absent (2) indicates that SFP interface is unplugged.ro
Enumeration
.1.3.6.1.4.1.4249.2.5.9.2.1.10
sfpDDMIfIndexIndex of interface in interfaces table, which state this SFP interface represents.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.4249.2.5.9.2.1.11
io
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.10
ioDIn
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.10.1
ioDInNumberNumber of digital inputs the device hasro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.10.1.1
ioDInTableDiscrete input table represents all discrete (digital) inputs present and configured in the device, including voltage inputs, dry contact inputs and any other.
SEQUENCE OF IoDInEntry
.1.3.6.1.4.1.4249.2.5.10.1.2
ioDInEntryDiscrete (digital) input
IoDInEntry
.1.3.6.1.4.1.4249.2.5.10.1.2.1
dInIdA unique index of discrete input. It should remain constant through any reconfiguration and reboot of the device.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.10.1.2.1.1
dInNameDiscrete input name, typically - connector marking.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.10.1.2.1.2
dInStateDiscrete input state. For voltage input values are high(3) or low(4). For npn or dry contact input it is open(1) or closed(2).ro
Enumeration
.1.3.6.1.4.1.4249.2.5.10.1.2.1.3
dInNormalStateNormal discrete input state. If it is any(5), then input is considered informative, else it is has normal (normally open or normally closed) and alarm state.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.10.1.2.1.4
dInAlarmSeveritydInAlarmSeverity allows systemAlarm variable to be triggered by the state of the input. Setting its to no(1) means that systemAlarm is not triggered; setting its to nonurgent(2) or urgent(3) will trigger the systemAlarm if dInState is not equal to dInNormalState.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.10.1.2.1.5
dInDescriptionUser configurable description: input purpose, meaning, net.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.10.1.2.1.6
dInTrapEnableIf true(1), trap will be sent on each change of dInState. If false(2), no traps will be sentrw
Enumeration
.1.3.6.1.4.1.4249.2.5.10.1.2.1.7
ioDOut
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.5.10.2
ioDOutNumberNumber of digital outputs the device hasro
IntegerNumber
.1.3.6.1.4.1.4249.2.5.10.2.1
ioDOutTableDiscrete output table represents all discrete outputs present and configured in the device, including relay outputs, voltage outputs, and any other.
SEQUENCE OF IoDOutEntry
.1.3.6.1.4.1.4249.2.5.10.2.2
ioDOutEntryDiscrete output
IoDOutEntry
.1.3.6.1.4.1.4249.2.5.10.2.2.1
dOutIdA unique index of discrete output. It should remain constant through any reconfiguration and reboot of the device.
IntegerIndex
.1.3.6.1.4.1.4249.2.5.10.2.2.1.1
dOutNameDiscrete output name, typically - connector marking.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.10.2.2.1.2
dOutStateDiscrete output state. For voltage output values are high(3) or low(4). For open-drain, npn, relay coil output (and other) it is active(1) or inactive(2). active(1) : coil energized, open-drain or npn output conducting current. inactive(2): coil de-energized, open-drain or npn output not conducting.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.10.2.2.1.3
dOutNormalStateNormal discrete output state. If it is any(5), then input is considered informative, else it is has normal (normally open or normally closed) and alarm state.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.10.2.2.1.4
dOutAlarmSeveritydOutAlarmSeverity allows systemAlarm variable to trigger the state of the output. Setting its to no(1) means that systemAlarm will not trigger; setting its to nonurgent(2) or urgent(3) will trigger the output by changing the dOutState to the opposite of dOutNormalState.rw
Enumeration
.1.3.6.1.4.1.4249.2.5.10.2.2.1.5
dOutDescriptionUser configurable description: output purpose, connected load, net.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.5.10.2.2.1.6
dOutTrapEnableIf true(1), trap will be sent on each change of dOutState. If false(2), no traps will be sentrw
Enumeration
.1.3.6.1.4.1.4249.2.5.10.2.2.1.7
statResetWriting reset(1) perform a device statistics reset. All device statistics should be re-initialized. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.5.11
maintenance
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.6
tftp
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.6.1
tftpServerIPThe IP address of the server from which the file is loaded. This value is not stored between device reboots and should be set before each TFTP operation.rw
IpAddress
.1.3.6.1.4.1.4249.2.6.1.1
tftpSoftFileNameThe remote filename for firmware upgrade. This value is not stored between device reboots and should be set before each TFTP operation.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.6.1.2
tftpConfFileNameThe remote filename for the up and download the startup-config. This value is not stored between device reboots and should be set before each TFTP operation.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.6.1.3
tftpConnectionTimeoutTime the device will wait for reply from TFTP server, during connection and while transferring a block of data. While waiting, the device will retransmit it's request each 8 seconds (typically). Thus it is reasonable to set the timeout to a multiple of 8 seconds. If during tftpConnectionTimeout device will not get a responce from the server, current TFTP operation will be retried several times (set by tftpNumRetries) before ending with and error.rw
Integer32
.1.3.6.1.4.1.4249.2.6.1.4
tftpNumRetriesNumber of times the device will retry to connect and perform requested operation (firmware download, configuration up/download) before stopping with error status.rw
Integer32
.1.3.6.1.4.1.4249.2.6.1.5
tftpTransCmdThis object, when read, always returns readValue(2). Setting this object will initiate following actions: swDownload(3) Download the firmware from TFTP server, filename on the server is specified by tftpSoftFileName. configDownload(4) Download the startup-config from the TFTP server, filename on the server is specified by tftpConfFileName. configUpLoad(5) Download the startup-config to the TFTP-Server, filename on the server is specified by tftpConfFileName. allDownload(6) Download the startup-config and firmware from the TFTP server. sdSwUpload(9) Upload software from main flash to SD card sdSwDownload(10) Download software from SD card sdConfigUpload(11) Upload the startup-config from main flash to SD card sdConfigDownload(12) Download the startup-config from SD card sdLoaderUpload(13) Upload bootloader from main flash to SD card sdLoaderDownload(14) Download bootloader from SD card sdCreateSnapshot(15) Upload Software, Loader and startup-config to SD card. Create filesystem if necesary noOp(1) Cancel all running SNMP-initiated TFTP operations. TFTP server IP address is configured by tftpServerIP variable. If device does not perform any other maintenance operations, the command will be executed, otherwise it will be denied. In case of command execution: The value of tftpLastOp will change to the value of the command. tftpTransferStatus will reflect transfer progress (connecting- transferringData-endedOk/error). Current timestamp will be saved into tftpLastOpTime variable. During the execution a series of tftpStatusChange is sent. In case of denial: tftpLastOp and tftpTransferStatus will not be affected. Current timestamp is also not saved into tftpLastOpTime variable. By quering tftpLastOpTime before and after setting the tftpTransCmd one can find out if the command was denied. Current operation that caused the denial can be queried by tftpLastOp. tftpStatusChange with tftpTransferStatus value of busyByOther is sent.rw
Enumeration
.1.3.6.1.4.1.4249.2.6.1.6
tftpLastOpThis object returns the last executed maintenance operation, regardless was it successful or not. It reports following actions: noOp(1) No maintenance operations were requested since last restart of the device. tftpSwDownload(3) Software download initiated from SNMP. tftpConfigDownload(4) Startup-config download initiated from SNMP. tftpConfigUpload(5) Startup-config upload initiated from SNMP. otherSwDownload(6) Software download, either TFTP or any other way, not initiated from SNMP. otherConfigDownload(7) Startup-config download, either TFTP or any other way, not initiated from SNMP. otherConfigUpload(8) Startup-config upload, either TFTP or any other way, not initiated from SNMP. sdSwUpload(9) Upload software from main flash to SD card sdSwDownload(10) Download software from SD card sdConfigUpload(11) Upload the startup-config from main flash to SD card sdConfigDownload(12) Download the startup-config from SD card sdLoaderUpload(13) Upload bootloader from main flash to SD card sdLoaderDownload(14) Download bootloader from SD card sdCreateSnapshot(15) Upload Software, Loader and startup-config to SD card. Create filesystem if necesaryro
Enumeration
.1.3.6.1.4.1.4249.2.6.1.7
tftpTransferStatusStatus of SNMP-initiated TFTP transfer. Results: noOp(1) Default, no TFTP operation was in progress. connecting(2) Device is connecting to the server specified by tftpServerIP. transferringData(3) TFTP data transfer is in progress. endedOk(4) TFTP transfer ended with success. error(5) TFTP data transfer ended with an Error, (e.g. server timeout or remote filename not found). Check TFTP server log file for details. busyByOther(6) This value can never be read directly from the MIB tree. It is used only in tftpStatusChange to notify that device is bysy with other maintenance operation and the request for another operation was denied. If tftpLastOp is tftpSwDownload(3), tftpConfigDownload(4) or tftpConfigUpload(5), this variable shows the status of exactly that operation. Transfers initiated by other means (for example CLI command TFTP operation or normal software download), do not change this variable. This way one can get full status of SNMP-initiated up/download without interference.ro
Enumeration
.1.3.6.1.4.1.4249.2.6.1.8
tftpLastOpTimeThe time in timeticks when last maintenance operation (TFTP software download or configuration up/download) was executed from SNMP by setting tftpTransCmd. If operation execution was denied, this variable is not affected. By comparing tftpLastOpTime before and after tftpTransCmd setting one can find out if the command was successful or denied.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.4249.2.6.1.9
tftpSoftConfirmWriting softConfirm(1) to tftpSoftConfirm will confirm previously uploaded firmware. Read always returns readValue(2).rw
Enumeration
.1.3.6.1.4.1.4249.2.6.1.10
tftpProtocolVersionAllows protocol selection between tftp(1), ftp(2) and sftp(3) for up/download. This value is not stored between device reboots and should be set before each operation.rw
Enumeration
.1.3.6.1.4.1.4249.2.6.1.11
tftpServerUserNameThe Username for Server access. This value is not stored between device reboots and should be set before each operation.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.6.1.12
tftpServerUserPassThe User Password for Server access. This value is not stored between device reboots and should be set before each operation.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.6.1.13
tftpServerPortNumberThe port number for accessing FTP or SFTP server. This value is not stored between device reboots and should be set before each operation.rw
Integer32
.1.3.6.1.4.1.4249.2.6.1.14
nateksSecurity
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.7
macFilter
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.7.1
macFilterConfigTableTable representing MAC-based filter configuration of network interfaces.
SEQUENCE OF MacFilterConfigEntry
.1.3.6.1.4.1.4249.2.7.1.1
macFilterConfigEntryMAC-based filter configuration of one interface
MacFilterConfigEntry
.1.3.6.1.4.1.4249.2.7.1.1.1
macFilterConfigIfIndexIndex in interfaces table of the configured interface.
IntegerIndex
.1.3.6.1.4.1.4249.2.7.1.1.1.1
macFilterConfigStatusIndicates, whether filtering is on(1) or off(2).ro
Enumeration
.1.3.6.1.4.1.4249.2.7.1.1.1.2
macFilterConfigActionSecurity action when non-permitted frame is received: filter - just drop the frame; indicate - drop the frame and send trap; block - drop the frame, send trap and permanently block the interface.ro
Enumeration
.1.3.6.1.4.1.4249.2.7.1.1.1.3
macFilterWhitelistTableWhite list of allowed MAC addresses.
SEQUENCE OF MacFilterWhitelistEntry
.1.3.6.1.4.1.4249.2.7.1.2
macFilterWhitelistEntryWhite list
MacFilterWhitelistEntry
.1.3.6.1.4.1.4249.2.7.1.2.1
macFilterWhitelistIndexIndex in whitelist table.
IntegerIndex
.1.3.6.1.4.1.4249.2.7.1.2.1.1
macFilterWhitelistIfIndexIfIndex of the related interface.
IntegerIndex
.1.3.6.1.4.1.4249.2.7.1.2.1.2
macFilterWhitelistMACPermitted MAC addressro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.7.1.2.1.3
macFilterViolationsTableList of several last MAC address security violations.
SEQUENCE OF MacFilterViolationsEntry
.1.3.6.1.4.1.4249.2.7.1.3
macFilterViolationsEntryViolations list
MacFilterViolationsEntry
.1.3.6.1.4.1.4249.2.7.1.3.1
macFilterViolationsIndexIndex in violations table.
IntegerIndex
.1.3.6.1.4.1.4249.2.7.1.3.1.1
macFilterViolationsIfIndexIfIndex of the related interface.ro
IntegerIndex
.1.3.6.1.4.1.4249.2.7.1.3.1.2
macFilterViolationsMACViolating MAC addressro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.4249.2.7.1.3.1.3
macFilterViolationsTimestampTimestamp of last time an action was taken against security violation performed by this MAC address on this interface. Measured in 1/100s of second from the last start of the unit - same as sysUpTime.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.4249.2.7.1.3.1.4
nateksDev
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.2.8
nateksMibInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.3
nateksMIBGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.3.1
nateksMIBCompliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.4249.3.2
NATEKS-MIB - SNMP MIB Reference | MIBs Explorer