MOXA-POE-BT-MIB
The MOXA-POE-BT-MIB module enables SNMP-based monitoring and management of Power over Ethernet (PoE) status and control parameters on Moxa network switches, specifically tracking per-port power consumption, injection states, and PoE budget utilization.
Imported Objects
Objects
70 total| Object Name |
|---|
moxa OBJECT IDENTIFIER .1.3.6.1.4.1.8691 |
poeThe MIB module defines Moxa PoE MODULE-IDENTITY .1.3.6.1.4.1.8691.608 |
mxPoeBt OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2 |
poeBtNotification OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2.0 |
poeBtNotifyPdPowerOnNotification indicates power output is on. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.1 |
poeBtNotifyPdPowerOffNotification indicates power output is off. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.2 |
poeBtNotifyLowInputVoltageNotification indicates input voltage is lower than 46 V. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.3 |
poeBtNotifyPdOverCurrentNotification indicates current is over power mode limitation. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.4 |
poeBtNotifyPdNoResponseNotification indicates check IP does not response to PD Failure Check. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.5 |
poeBtNotifyOverBudgetLimitNotification indicates power consumption is over budget. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.6 |
poeBtNotifyPdDetectionFailureNotification indicates PD detection fail due to invalid signature. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.7 |
poeBtNotifyNonPdOrPdShortCircuitNotification indicates Non-PD or PD short circuited. NOTIFICATION-TYPE .1.3.6.1.4.1.8691.608.2.0.8 |
poeBtConfiguration OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2.1 |
poeBtConfigGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2.1.1 |
poeBtConfigPowerOutputUsers configure power output to control PoE power output on or off.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.1.1.1 |
poeBtConfigAutoPowerCuttingUsers enable Auto Power Cutting make the lowest and the less port number port be cut if consumption over system budgetrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.1.1.2 |
poeBtConfigSystemPowerBudgetUsers configure system power budget to limit maximun available power for all PoE devices. Please refer to EPS abilities to configure this value.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.1.3 |
poeBtConfigPortTableA table contains general port configuration infomations. SEQUENCE OF PoeBtConfigPortEntry .1.3.6.1.4.1.8691.608.2.1.1.4 |
poeBtConfigPortEntryA table entry contains general port configuration infomations. PoeBtConfigPortEntry .1.3.6.1.4.1.8691.608.2.1.1.4.1 |
poeBtConfigPortIndexIndex of poeBtConfigPortTable.ro INTEGER .1.3.6.1.4.1.8691.608.2.1.1.4.1.1 |
poeBtConfigPortPowerOutputUsers configure port power output to control PoE power output on or off per ports.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.1.1.4.1.2 |
poeBtConfigOutputModeUsers configure output mode according to the type of PoE devices.rw Enumeration .1.3.6.1.4.1.8691.608.2.1.1.4.1.3 |
poeBtConfigPowerAllocationUsers configure power allocation to set power output limit per ports.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.1.4.1.4 |
poeBtConfigLegacyPdDetectionEnable Legacy PD Detection to loose PoE detection signature.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.1.1.4.1.5 |
poeBtConfigPriorityUsers configure priority to change Auto Cutting priority of portsrw Enumeration .1.3.6.1.4.1.8691.608.2.1.1.4.1.6 |
poeBtConfigPowerManagementModeUsers configure power management mode according to power usage of powered devices.rw Enumeration .1.3.6.1.4.1.8691.608.2.1.1.5 |
poeBtConfigFailureCheck OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2.1.2 |
poeBtConfigFcPortTableA table contains PD Failure Check port configuration infomations. SEQUENCE OF PoeBtConfigFcPortEntry .1.3.6.1.4.1.8691.608.2.1.2.1 |
poeBtConfigFcPortEntryA table entry contains PD Failure Check port configuration infomations. PoeBtConfigFcPortEntry .1.3.6.1.4.1.8691.608.2.1.2.1.1 |
poeBtConfigFcPortIndexIndex of poeBtConfigFcPortTable.ro INTEGER .1.3.6.1.4.1.8691.608.2.1.2.1.1.1 |
poeBtConfigFcEnableUsers configure PD Failure Check enabled to enable PD Failure Check on the port.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.1.2.1.1.2 |
poeBtConfigFcDeviceIpUsers configure check IP for PD Failure Check to check the IP periodically.rw IpAddress .1.3.6.1.4.1.8691.608.2.1.2.1.1.3 |
poeBtConfigFcNoResponseTimesUsers configure no response timeout to set action trigger threshold.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.2.1.1.4 |
poeBtConfigFcCheckFrequencyUsers configure check period to change IP check interval.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.2.1.1.5 |
poeBtConfigFcActionUsers configure action to set trigger action if fail times hits thresholdrw Enumeration .1.3.6.1.4.1.8691.608.2.1.2.1.1.6 |
poeBtConfigScheduling OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2.1.3 |
poeBtConfigScheRuleTableA table contains Scheduling rule configuration infomations. SEQUENCE OF PoeBtConfigScheRuleEntry .1.3.6.1.4.1.8691.608.2.1.3.1 |
poeBtConfigScheRuleEntryA table entry contains Scheduling rule configuration infomations. PoeBtConfigScheRuleEntry .1.3.6.1.4.1.8691.608.2.1.3.1.1 |
poeBtConfigRuleIndexIndex of poeBtConfigScheRuleTable.ro INTEGER .1.3.6.1.4.1.8691.608.2.1.3.1.1.1 |
poeBtConfigScheNameRule namerw DisplayString .1.3.6.1.4.1.8691.608.2.1.3.1.1.2 |
poeBtConfigScheEnableUsers enable rule to make the rule valid.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.1.3.1.1.3 |
poeBtConfigScheStartDateYearUsers configure year of rule start date.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.3.1.1.4 |
poeBtConfigScheStartDateMonthUsers configure month of rule start date.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.3.1.1.5 |
poeBtConfigScheStartDateDayUsers configure day of rule state date.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.3.1.1.6 |
poeBtConfigScheStartTimeHourUsers configure hour of rule start time.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.3.1.1.7 |
poeBtConfigScheStartTimeMinUsers configure minute of rule start time.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.3.1.1.8 |
poeBtConfigScheEndTimeHourUsers configure hour of rule end time.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.3.1.1.9 |
poeBtConfigScheEndTimeMinUsers configure minute of rule end time.rw Integer32 .1.3.6.1.4.1.8691.608.2.1.3.1.1.10 |
poeBtConfigScheRepeatOnUsers configure the rule repeat on which days.rw OCTET STRING .1.3.6.1.4.1.8691.608.2.1.3.1.1.11 |
poeBtConfigScheAppliedPortsUsers configure the rule also applied on which ports.rw OCTET STRING .1.3.6.1.4.1.8691.608.2.1.3.1.1.12 |
poeBtConfigScheRowStatusThe status column used for creating, modifying, and deleting entries of poeBtConfigScheRuleTablerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.1.3.1.1.13 |
poeBtStatus OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2.2 |
poeBtStatMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.8691.608.2.2.1 |
poeBtStatMaxInputPowerPoE total input power.ro Integer32 .1.3.6.1.4.1.8691.608.2.2.1.1 |
poeBtStatActualPowerPoE actual input power from power supply.ro Integer32 .1.3.6.1.4.1.8691.608.2.2.1.2 |
poeBtStatBudgetLimitPoE power budget.ro Integer32 .1.3.6.1.4.1.8691.608.2.2.1.3 |
poeBtStatConsumedPowerPoE current total consumption.ro Integer32 .1.3.6.1.4.1.8691.608.2.2.1.4 |
poeBtStatRemainingAvailablePowerPoE remaining power.ro Integer32 .1.3.6.1.4.1.8691.608.2.2.1.5 |
poeBtStatPortTableA table contains port status infomations. SEQUENCE OF PoeBtStatPortEntry .1.3.6.1.4.1.8691.608.2.2.1.6 |
poeBtStatPortEntryA table entry contains port status infomations. PoeBtStatPortEntry .1.3.6.1.4.1.8691.608.2.2.1.6.1 |
poeBtStatPortIndexPort index.ro INTEGER .1.3.6.1.4.1.8691.608.2.2.1.6.1.1 |
poeBtStatPowerOutputPower output of the port.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.2.1.6.1.2 |
poeBtStatClassificationPD classification of the port. class0(0), class1(1), class2(2), class3(3), class4(4), class5(5), class6(6), class7(7), class8(8), unknown(10), overCurrent(11)ro OCTET STRING .1.3.6.1.4.1.8691.608.2.2.1.6.1.3 |
poeBtStatCurrentPD current of the port.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.2.1.6.1.4 |
poeBtStatVoltagePD voltage of the port.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.2.1.6.1.5 |
poeBtStatConsumptionPD consumption of the port.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.8691.608.2.2.1.6.1.6 |
poeBtStatDeviceTypePD device type of the port.ro Enumeration .1.3.6.1.4.1.8691.608.2.2.1.6.1.7 |
poeBtStatConfigSuggestionConfiguration suggestion of the port.ro Enumeration .1.3.6.1.4.1.8691.608.2.2.1.6.1.8 |
poeBtStatPdFailureCheckStatusPD Failure Check operating status.ro Enumeration .1.3.6.1.4.1.8691.608.2.2.1.6.1.9 |
poeBtStatAllocatedPowerPoE current total budget.ro INTEGER .1.3.6.1.4.1.8691.608.2.2.1.7 |
More MIBs from Moxa Automation
Browse all Moxa AutomationMIBs →The MOXA-AWK4131A-MIB module enables SNMP-based monitoring and management of the Moxa AWK-4131A series of wireless access points, specifically exposing device status, interface statistics, and RF performance metrics. This module facilitates the collection of operational data such as client association counts, signal strength, and hardware health indicators for network administration.
The MOXA-IKS6728A-8POE-MIB enables SNMP-based monitoring and management of the Moxa IKS-6728A-8POE managed industrial Ethernet switch, providing access to device status, port statistics, PoE power allocation metrics, and environmental sensor data.
The MOXA-EDSG512EPoE-MIB module enables SNMP-based monitoring and management of Moxa EDS-G512E-PoE industrial Ethernet switches, specifically exposing device status, port statistics, PoE power allocation data, and environmental sensor readings.
The MOXA-EDS528E-MIB module enables SNMP-based monitoring and management of Moxa EDS-528E managed Ethernet switches, providing access to device-specific operational metrics such as port status, traffic counters, temperature sensors, and power supply states.
The MOXA-IKS6728A-MIB enables SNMP-based monitoring and management of Moxa IKS-6728A industrial Ethernet switches, exposing device-specific operational metrics such as port status, traffic counters, temperature sensors, and power supply states. This module facilitates granular visibility into the health and performance of the IKS-6728A series within industrial automation networks.
The MOXA-EDSP506E-MIB enables SNMP-based monitoring and management of Moxa EDS-P506E series managed Ethernet switches, exposing device-specific operational metrics such as port status, traffic counters, temperature sensors, and power supply states.