Home/Catalog/MOXA-FIBER-CHECK-MIB

MOXA-FIBER-CHECK-MIB

AI MIB Summary

The MOXA-FIBER-CHECK-MIB enables SNMP-based monitoring of optical fiber link integrity and physical layer diagnostics on Moxa industrial networking devices. It tracks critical metrics such as fiber attenuation, optical power levels (Rx/Tx), and link status to detect physical layer faults or degradation in fiber optic connections.

The MIB module defines Moxa Fiber Check
Main OID:
mxFiberCheck.1.3.6.1.4.1.8691.603.5.3
33
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

33 total
Object Name
mxFiberCheckThe MIB module defines Moxa Fiber Check
MODULE-IDENTITY
.1.3.6.1.4.1.8691.603.5.3
fiberCheckNotification
OBJECT IDENTIFIER
.1.3.6.1.4.1.8691.603.5.3.0
fiberCheckNotifyFiberCheckWarningNotification indicates fiber check warning.
NOTIFICATION-TYPE
.1.3.6.1.4.1.8691.603.5.3.0.1
fiberCheckConfiguration
OBJECT IDENTIFIER
.1.3.6.1.4.1.8691.603.5.3.1
fiberCheckConfigGeneral
OBJECT IDENTIFIER
.1.3.6.1.4.1.8691.603.5.3.1.1
fiberCheckConfigPortTableThe Fiber Check table of general config function.
SEQUENCE OF FiberCheckConfigPortEntry
.1.3.6.1.4.1.8691.603.5.3.1.1.1
fiberCheckConfigPortEntryThe Fiber Check table entry of general config function.
FiberCheckConfigPortEntry
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1
fiberCheckConfigPortIndexThe fiber index of config function.ro
INTEGER
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.1
fiberCheckConfigModeUsers configure mode to define threshold by user.rw
Enumeration
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.2
fiberCheckConfigTemperatureWarnCUsers configure the high warning value of fiber temperature (Celsius) to determine which value issue the fiber check warning.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.3
fiberCheckConfigTemperatureWarnFUsers configure the high warning value of fiber temperature (Fahrenheit) to determine which value issue the fiber check warning.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.4
fiberCheckConfigTxPowerWarnHighUsers configure the high warning value of fiber tx power to determine which value issue the fiber check warning.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.5
fiberCheckConfigTxPowerWarnLowUsers configure the low warning value of fiber tx power to determine which value issue the fiber check warning.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.6
fiberCheckConfigRxPowerWarnHighUsers configure the high warning value of fiber rx power to determine which value issue the fiber check warning.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.7
fiberCheckConfigRxPowerWarnLowUsers configure the low warning value of fiber rx power to determine which value issue the fiber check warning.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.8
fiberCheckConfigResetToDefaultWriting true(1) to this object forces the system to reset this port's fiber check configuration to default. Any other operation on this object has no effect and it always returns false(2) when read.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.1.1.1.1.9
fiberCheckStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.8691.603.5.3.2
fiberCheckStatMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.8691.603.5.3.2.1
fiberCheckStatPortTableThe fiber check table.
SEQUENCE OF FiberCheckStatPortEntry
.1.3.6.1.4.1.8691.603.5.3.2.1.1
fiberCheckStatPortEntryThe fiber check table entry.
FiberCheckStatPortEntry
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1
fiberCheckStatPortIndexThe port index fiber module.ro
INTEGER
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.1
fiberCheckStatModelNameThe model name of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.2
fiberCheckStatSNThe serial number of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.3
fiberCheckStatWaveLengthThe wavelength of fiber module.ro
INTEGER
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.4
fiberCheckStatTemperatureCThe temperature(Celsius) of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.5
fiberCheckStatTemperatureFThe temperature(Fahrenheit) of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.6
fiberCheckStatVoltageThe voltage of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.7
fiberCheckStatTxPowerThe tx power of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.8
fiberCheckStatRxPowerThe rx power of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.9
fiberCheckStatTemperatureLimitCThe temperature(Celsius) warning limit of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.10
fiberCheckStatTemperatureLimitFThe temperature(Fahrenheit) warning limit of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.11
fiberCheckStatTxPowerLimitThe tx power warning limit of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.12
fiberCheckStatRxPowerLimitThe rx power warning limit of fiber module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.8691.603.5.3.2.1.1.1.13

More MIBs from Moxa Automation

Browse all Moxa AutomationMIBs →
MOXA-AWK4131A-MIB

The MOXA-AWK4131A-MIB module enables SNMP-based monitoring and management of the Moxa AWK-4131A series of wireless access points, specifically exposing device status, interface statistics, and RF performance metrics. This module facilitates the collection of operational data such as client association counts, signal strength, and hardware health indicators for network administration.

833 objects→
MOXA-IKS6728A-8POE-MIB

The MOXA-IKS6728A-8POE-MIB enables SNMP-based monitoring and management of the Moxa IKS-6728A-8POE managed industrial Ethernet switch, providing access to device status, port statistics, PoE power allocation metrics, and environmental sensor data.

772 objects→
MOXA-EDSG512EPoE-MIB

The MOXA-EDSG512EPoE-MIB module enables SNMP-based monitoring and management of Moxa EDS-G512E-PoE industrial Ethernet switches, specifically exposing device status, port statistics, PoE power allocation data, and environmental sensor readings.

763 objects→
MOXA-EDS528E-MIB

The MOXA-EDS528E-MIB module enables SNMP-based monitoring and management of Moxa EDS-528E managed Ethernet switches, providing access to device-specific operational metrics such as port status, traffic counters, temperature sensors, and power supply states.

728 objects→
MOXA-IKS6728A-MIB

The MOXA-IKS6728A-MIB enables SNMP-based monitoring and management of Moxa IKS-6728A industrial Ethernet switches, exposing device-specific operational metrics such as port status, traffic counters, temperature sensors, and power supply states. This module facilitates granular visibility into the health and performance of the IKS-6728A series within industrial automation networks.

723 objects→
MOXA-EDSP506E-MIB

The MOXA-EDSP506E-MIB enables SNMP-based monitoring and management of Moxa EDS-P506E series managed Ethernet switches, exposing device-specific operational metrics such as port status, traffic counters, temperature sensors, and power supply states.

714 objects→