64 total| Object Name |
|---|
polPowerOverLan MODULE-IDENTITY .1.3.6.1.4.1.7428 |
products OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1 |
description OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1 |
sysObjectID OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1 |
midspanUnknown OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.1 |
midspan6portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.2 |
midspan6portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.3 |
midspan12portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.4 |
midspan12portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.5 |
midspan24portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.6 |
midspan24portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.7 |
midspan48portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.8 |
midspan48portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.9 |
midspan6portHPAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.10 |
midspan6portHPACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.11 |
midspan12portHPAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.12 |
midspan12portHPACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.13 |
midspanGigabit6portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.14 |
midspanGigabit12portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.15 |
midspanGigabit24portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.16 |
midspanHiPoEGigabit6portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.17 |
midspanHiPoEGigabit12portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.18 |
midspanHiPoEGigabit24portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.19 |
midspanHiPoEATGigabit6portAC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.20 |
midspanHiPoEATGigabit12portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.21 |
midspanHiPoEATGigabit24portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.22 |
midspan4PairATGigabit6portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.23 |
midspan4PairATGigabit12portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.24 |
midspanHiPoEATGigabit6portDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.25 |
midspanHiPoEATGigabit12portDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.26 |
midspanHiPoEATGigabit24portDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.27 |
midspan4PairATGigabit24portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.28 |
midspanEEPoEGigabit24portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.29 |
midspanPoHGigabit6portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.30 |
midspanPoHGigabit12portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.31 |
midspanPoHGigabit24portACDC OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.1.1.32 |
pseDevice OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.2 |
portObjects OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.2.1 |
portTableA table of objects that display and control the power
characteristics of power Ethernet ports on a Power Source
Entity (PSE) device. This group will be implemented in
managed power Ethernet switches and mid-span devices.
Values of all read-write objects in this table are
persistent at restart/reboot. SEQUENCE OF PortEntry .1.3.6.1.4.1.7428.1.2.1.1 |
portEntryA set of objects that display and control the power
characteristics of a power Ethernet PSE port. PortEntry .1.3.6.1.4.1.7428.1.2.1.1.1 |
portGroupIndexThis variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices. Integer32 .1.3.6.1.4.1.7428.1.2.1.1.1.1 |
portIndexThis variable uniquely identifies the power Ethernet PSE
port within group portGroupIndex to which the
power Ethernet PSE entry is connected. Integer32 .1.3.6.1.4.1.7428.1.2.1.1.1.2 |
portConsumptionPowerA read-only value indicates the measured usage power expressed in Watts for a specific portro Gauge32 UNITS "Watt" .1.3.6.1.4.1.7428.1.2.1.1.1.3 |
portMaxPowerRead/Write maximum power consumption that PD device may consume in Watts
NOTE:
1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt
2. For Midspan 70xxG series, Max PD power consumption = 30Watt
3 .For Midspan 80xx series, this parameter is read-only !!
4. For Midspan 90xxG series, Max PD power consumption = 30/36Watt
5. For Midspan 95xxG series, Max PD power consumption = 60/72Watt (four pair) or 30/36Watt (two pair)
6. For Midspan 55xxG series, Max PD power consumption = 30/36Wattrw Integer32 .1.3.6.1.4.1.7428.1.2.1.1.1.4 |
portTypeEnable/Disable Four-pair/EEPoE PoE
Read : Applicable to all Midspan series
Write: Applicable only to 95xxG/55xxG Midspan series
twopair (1) Two-pair PoE port capable of providing up to 16.8Watt or 30-36Watt.
fourpair (2) Four-pair/EEPoE-mode PoE port capable of providing up to 60-72Watt (95xxG) or 30-36W (55xxG).rw Enumeration .1.3.6.1.4.1.7428.1.2.1.1.1.5 |
mainObjects OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.2.2 |
mainPseTableA table of objects that display and control attributes
of the main PSE device. SEQUENCE OF MainPseEntry .1.3.6.1.4.1.7428.1.2.2.1 |
mainPseEntryA set of objects that display and control the Main PSE device. MainPseEntry .1.3.6.1.4.1.7428.1.2.2.1.1 |
mainGroupIndexThis variable uniquely identifies the group to which
power Ethernet PSE is connected. Group means (box in
the stack, module in a rack) and the value 1 MUST be
used for non-modular devices. Integer32 .1.3.6.1.4.1.7428.1.2.2.1.1.1 |
mainVoltagePower Supply Voltage in Volt.ro Gauge32 .1.3.6.1.4.1.7428.1.2.2.1.1.2 |
mainDetectionMethodRead/Write PD device detection method (802.3af / 802.3af+Legacy).rw Enumeration .1.3.6.1.4.1.7428.1.2.2.1.1.3 |
mainPowerUsageBudgetAllow external SNMP manager to limit maximum power that all PD's may consume
Whenever total power consumption exceeds maximum power, Midspan may turn off
automatically Low priority and High priority PSE ports.
Percentage Value refers to Midspan maximum power.rw Integer32 .1.3.6.1.4.1.7428.1.2.2.1.1.4 |
mainPSEMaxPowerMaximum power that Midspan can provide (Watt), after including power budget percentage limitation.
Example: Midspan maximum power without power limit = 860Watt, and Power Limit = 50%
mainPSEMaxPower = 430Wattro Gauge32 .1.3.6.1.4.1.7428.1.2.2.1.1.5 |
highPowerLegacyPDSupportApplicable only for Midspan 90xxG series
enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device).
disable(2) - Power only 802.3at compliant devices.
notsupported(3) - SNMP GET result for Midspan which doesn't support this featurerw Enumeration .1.3.6.1.4.1.7428.1.2.2.1.1.6 |
highPowerExtendedPortPowerApplicable only for Midspan 90xxG/55xxG series
enable (1) - Extend maximum power to PD device beyond 802.3at specification.
disable(2) - Maximum power to PD device per 802.3at specification.
notsupported(3) - SNMP GET result for Midspan which doesn't support this featurerw Enumeration .1.3.6.1.4.1.7428.1.2.2.1.1.7 |
powerBackupStatusApplicable only for Midspan 90xxG/95xxG/55xxG series
standalone - Midspan isn't connected to any power backup device
powerbackupbyrps - Redundant power supply (RPS) backup Midspan device
powerbackupbymidspan - Two Midspan devices backup each other
incompatiblepowerbackupdevice - Midspan was connected to incompatible power backup device.
For example RPS 430Watt to Midspan 950Wattro Enumeration .1.3.6.1.4.1.7428.1.2.2.1.1.8 |
internalPowerSourceStatusApplicable only for Midspan 90xxG/95xxG/55xxG series
ok(1) - Internal Power Source is OK
fail(2) - Internal Power Source failurero Enumeration .1.3.6.1.4.1.7428.1.2.2.1.1.9 |
externalPowerSourceStatusApplicable only for Midspan 90xxG/95xxG/55xxG series
ok(1) - External Power Source is OK
fail(2) - External Power Source failure
notsupported(3) - SNMP GET result for Midspan which doesn't support this featurero Enumeration .1.3.6.1.4.1.7428.1.2.2.1.1.10 |
temperatureUnit temperature - Applicable only for Midspan 95xxG seriesro INTEGER UNITS "Degree" .1.3.6.1.4.1.7428.1.2.2.1.1.11 |
temperatureformatUnit temperature format - Applicable only for Midspan 95xxG series
Celcius(1) - Report unit temperature in Celcius
Fahrenheit(2) - Report unit temperature in Fahrenheit
NotSupported(3) - No temperature sensor inside the Midspan unitrw Enumeration .1.3.6.1.4.1.7428.1.2.2.1.1.12 |
poeNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.7428.1.3 |
powerBackupStatusNotificationApplicable only for Midspan 90xxG/95xxG/55xxG series
This Notification reports power backup status change, and whenever incompatible
power backup source is connected (as RPS 430Watt to Midspan 950Watt) NOTIFICATION-TYPE .1.3.6.1.4.1.7428.1.3.1 |
internalPowerSourceStatusNotificationApplicable only for Midspan 90xxG/95xxG/55xxG series
This Notification reports internal Power Source failure NOTIFICATION-TYPE .1.3.6.1.4.1.7428.1.3.2 |
externalPowerSourceStatusNotificationApplicable only for Midspan 90xxG/95xxG/55xxG series
This Notification reports external Power Source failure NOTIFICATION-TYPE .1.3.6.1.4.1.7428.1.3.3 |