Home/Catalog/MICROSEMI-PDSINE-MIB

MICROSEMI-PDSINE-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

64
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

64 total
Object Name
polPowerOverLan
MODULE-IDENTITY
.1.3.6.1.4.1.7428
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1
description
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1
sysObjectID
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1
midspanUnknown
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.1
midspan6portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.2
midspan6portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.3
midspan12portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.4
midspan12portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.5
midspan24portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.6
midspan24portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.7
midspan48portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.8
midspan48portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.9
midspan6portHPAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.10
midspan6portHPACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.11
midspan12portHPAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.12
midspan12portHPACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.13
midspanGigabit6portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.14
midspanGigabit12portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.15
midspanGigabit24portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.16
midspanHiPoEGigabit6portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.17
midspanHiPoEGigabit12portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.18
midspanHiPoEGigabit24portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.19
midspanHiPoEATGigabit6portAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.20
midspanHiPoEATGigabit12portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.21
midspanHiPoEATGigabit24portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.22
midspan4PairATGigabit6portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.23
midspan4PairATGigabit12portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.24
midspanHiPoEATGigabit6portDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.25
midspanHiPoEATGigabit12portDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.26
midspanHiPoEATGigabit24portDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.27
midspan4PairATGigabit24portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.28
midspanEEPoEGigabit24portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.29
midspanPoHGigabit6portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.30
midspanPoHGigabit12portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.31
midspanPoHGigabit24portACDC
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.1.1.32
pseDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.2
portObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.2.1
portTableA table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices. Values of all read-write objects in this table are persistent at restart/reboot.
SEQUENCE OF PortEntry
.1.3.6.1.4.1.7428.1.2.1.1
portEntryA set of objects that display and control the power characteristics of a power Ethernet PSE port.
PortEntry
.1.3.6.1.4.1.7428.1.2.1.1.1
portGroupIndexThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices.
Integer32
.1.3.6.1.4.1.7428.1.2.1.1.1.1
portIndexThis variable uniquely identifies the power Ethernet PSE port within group portGroupIndex to which the power Ethernet PSE entry is connected.
Integer32
.1.3.6.1.4.1.7428.1.2.1.1.1.2
portConsumptionPowerA read-only value indicates the measured usage power expressed in Watts for a specific portro
Gauge32 UNITS "Watt"
.1.3.6.1.4.1.7428.1.2.1.1.1.3
portMaxPowerRead/Write maximum power consumption that PD device may consume in Watts NOTE: 1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt 2. For Midspan 70xxG series, Max PD power consumption = 30Watt 3 .For Midspan 80xx series, this parameter is read-only !! 4. For Midspan 90xxG series, Max PD power consumption = 30/36Watt 5. For Midspan 95xxG series, Max PD power consumption = 60/72Watt (four pair) or 30/36Watt (two pair) 6. For Midspan 55xxG series, Max PD power consumption = 30/36Wattrw
Integer32
.1.3.6.1.4.1.7428.1.2.1.1.1.4
portTypeEnable/Disable Four-pair/EEPoE PoE Read : Applicable to all Midspan series Write: Applicable only to 95xxG/55xxG Midspan series twopair (1) Two-pair PoE port capable of providing up to 16.8Watt or 30-36Watt. fourpair (2) Four-pair/EEPoE-mode PoE port capable of providing up to 60-72Watt (95xxG) or 30-36W (55xxG).rw
Enumeration
.1.3.6.1.4.1.7428.1.2.1.1.1.5
mainObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.2.2
mainPseTableA table of objects that display and control attributes of the main PSE device.
SEQUENCE OF MainPseEntry
.1.3.6.1.4.1.7428.1.2.2.1
mainPseEntryA set of objects that display and control the Main PSE device.
MainPseEntry
.1.3.6.1.4.1.7428.1.2.2.1.1
mainGroupIndexThis variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices.
Integer32
.1.3.6.1.4.1.7428.1.2.2.1.1.1
mainVoltagePower Supply Voltage in Volt.ro
Gauge32
.1.3.6.1.4.1.7428.1.2.2.1.1.2
mainDetectionMethodRead/Write PD device detection method (802.3af / 802.3af+Legacy).rw
Enumeration
.1.3.6.1.4.1.7428.1.2.2.1.1.3
mainPowerUsageBudgetAllow external SNMP manager to limit maximum power that all PD's may consume Whenever total power consumption exceeds maximum power, Midspan may turn off automatically Low priority and High priority PSE ports. Percentage Value refers to Midspan maximum power.rw
Integer32
.1.3.6.1.4.1.7428.1.2.2.1.1.4
mainPSEMaxPowerMaximum power that Midspan can provide (Watt), after including power budget percentage limitation. Example: Midspan maximum power without power limit = 860Watt, and Power Limit = 50% mainPSEMaxPower = 430Wattro
Gauge32
.1.3.6.1.4.1.7428.1.2.2.1.1.5
highPowerLegacyPDSupportApplicable only for Midspan 90xxG series enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device). disable(2) - Power only 802.3at compliant devices. notsupported(3) - SNMP GET result for Midspan which doesn't support this featurerw
Enumeration
.1.3.6.1.4.1.7428.1.2.2.1.1.6
highPowerExtendedPortPowerApplicable only for Midspan 90xxG/55xxG series enable (1) - Extend maximum power to PD device beyond 802.3at specification. disable(2) - Maximum power to PD device per 802.3at specification. notsupported(3) - SNMP GET result for Midspan which doesn't support this featurerw
Enumeration
.1.3.6.1.4.1.7428.1.2.2.1.1.7
powerBackupStatusApplicable only for Midspan 90xxG/95xxG/55xxG series standalone - Midspan isn't connected to any power backup device powerbackupbyrps - Redundant power supply (RPS) backup Midspan device powerbackupbymidspan - Two Midspan devices backup each other incompatiblepowerbackupdevice - Midspan was connected to incompatible power backup device. For example RPS 430Watt to Midspan 950Wattro
Enumeration
.1.3.6.1.4.1.7428.1.2.2.1.1.8
internalPowerSourceStatusApplicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - Internal Power Source is OK fail(2) - Internal Power Source failurero
Enumeration
.1.3.6.1.4.1.7428.1.2.2.1.1.9
externalPowerSourceStatusApplicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - External Power Source is OK fail(2) - External Power Source failure notsupported(3) - SNMP GET result for Midspan which doesn't support this featurero
Enumeration
.1.3.6.1.4.1.7428.1.2.2.1.1.10
temperatureUnit temperature - Applicable only for Midspan 95xxG seriesro
INTEGER UNITS "Degree"
.1.3.6.1.4.1.7428.1.2.2.1.1.11
temperatureformatUnit temperature format - Applicable only for Midspan 95xxG series Celcius(1) - Report unit temperature in Celcius Fahrenheit(2) - Report unit temperature in Fahrenheit NotSupported(3) - No temperature sensor inside the Midspan unitrw
Enumeration
.1.3.6.1.4.1.7428.1.2.2.1.1.12
poeNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.7428.1.3
powerBackupStatusNotificationApplicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports power backup status change, and whenever incompatible power backup source is connected (as RPS 430Watt to Midspan 950Watt)
NOTIFICATION-TYPE
.1.3.6.1.4.1.7428.1.3.1
internalPowerSourceStatusNotificationApplicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports internal Power Source failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.7428.1.3.2
externalPowerSourceStatusNotificationApplicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports external Power Source failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.7428.1.3.3