The LUMINOUS-SHELF-MIB provides SNMP management capabilities for Luminous optical shelf hardware, exposing metrics for shelf status, port states, and line card inventory. It enables the monitoring of physical layer components and environmental sensors specific to Luminous optical transport equipment.

The Luminous Shelf MIB contains Information related to the equipment contained in Luminous Shelf.
Main OID:
lumADMShelfMIB.1.3.6.1.4.1.4614.1.1
57
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

57 total
Object Name
luminous
OBJECT IDENTIFIER
.1.3.6.1.4.1.4614
lumADM
OBJECT IDENTIFIER
.1.3.6.1.4.1.4614.1
lumADMShelfMIBThe Luminous Shelf MIB contains Information related to the equipment contained in Luminous Shelf.
MODULE-IDENTITY
.1.3.6.1.4.1.4614.1.1
lumADMShelf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4614.1.1.1
lumNodeIdUsed to identify the node.ro
Integer32
.1.3.6.1.4.1.4614.1.1.1.1
lumShelfIdShelf IDro
OCTET STRING
.1.3.6.1.4.1.4614.1.1.1.2
lumNodeTypeA Central Office(CO) or Customer Premise Equipment(CPE). CO nodes act as timing sources for the ring.rw
Enumeration
.1.3.6.1.4.1.4614.1.1.1.3
lumShelfTypeLMS shelf type. This object may be used to identify Luminous shelves/nodes types.ro
LumShelfType (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.1.4
lumShelfHWVersionThe Shelf Hardware Version.ro
LumVersionString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.1.5
lumShelfSerialNumberLuminous assigned Shelf Serial Numberro
LumSerialNumString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.1.6
lumShelfCleiCodeThe CLEI code of the shelf.ro
LumCleiString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.1.7
lumShelfManufactureDateThe date this shelf has been manufactured.ro
LumManufactureString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.1.8
lumNodeStatusminorAlarm(2) indicates that no action is needed but some alarming event has happened. minorFailure(3) indicates that a fault has occured but does not persist. The action from the management may not be needed. criticalFailure(4) indicates that the shelf cannot function properly. The management action is recommended (can be even reset or, if mulfunctioning, be replace) to correct the problem. Otherwise the problem may persist. This field is only an indication to the management of the failure/alarm occured. The management may decide to discover the route cause of the problem by analizing MIB objects on this and other shelves.ro
Enumeration
.1.3.6.1.4.1.4614.1.1.1.9
lumShelfChangesNumber of shelf changes such as card inserts/removes, switchovers, downloads (i.e. ones resulting in traps) since the last reboot.ro
Counter32
.1.3.6.1.4.1.4614.1.1.1.10
lumShelfCommandreset (2) - resets the shelf.rw
Enumeration
.1.3.6.1.4.1.4614.1.1.1.11
lumPrimaryOptinetClockSourcePortifIndex of the port desired to be used as as a primary optinet clock source. Can be set on CO nodes only.rw
Integer32
.1.3.6.1.4.1.4614.1.1.1.12
lumSecondaryOptinetClockSourcePortifIndex of the port desired to be used as as a secondary optinet clock source. Can be set on CO nodes only.rw
Integer32
.1.3.6.1.4.1.4614.1.1.1.13
lumCurrentOptinetClockSourcePortThe current source of the optinet clock. primary(3), secondary(4) can be reported only on CO nodes, and indicate which clock source has been currently selected by this CO node. clockWise(5), counterClockWise(6) can be reported only on CPE nodes and indicate the ring direction to the closest CO node from where the clock source is taken. none(1) indicates that the clock source has not been chosen. internal(2) indicates a node using its internal oscillator for a clock source. The internal oscillator is an oven-controlled oscillator (OCXO) on the switch(ring) card.ro
Enumeration
.1.3.6.1.4.1.4614.1.1.1.14
lumShelfCurrentTimeThe current date and time on this shelf.ro
LumDateTimeString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.1.15
lumSyncTypeThis control the behaviour of the timing synchronisation for this node.rw
Enumeration
.1.3.6.1.4.1.4614.1.1.1.16
lumADMCard
OBJECT IDENTIFIER
.1.3.6.1.4.1.4614.1.1.2
lumADMCardTableLuminous Card Table.
SEQUENCE OF LumADMCardEntry
.1.3.6.1.4.1.4614.1.1.2.1
lumADMCardEntry.
LumADMCardEntry
.1.3.6.1.4.1.4614.1.1.2.1.1
lumShelfPlaneEither front or back plane.ro
LumChassisPlane (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.1
lumSlotIDStarts with 1 for the both front plane and for the back plane. The second slot of the double-slot cards is reported as with lumCardType equal to none(1).ro
LumSlotNum (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.2
lumCardTypeThe type of a card in the slot. none(1)indicates that the card is either not present in the slot. present(38)indicates that the card is present but not responding. In order to pre-allocate a slot for a particular card type, an SNMP Manager must change the value of a lumCardType object instance from the value of none(1) to the desired value.rw
LumCardType (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.3
lumCardHWVersionThe version of the card's hardware.ro
LumVersionString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.4
lumCardSWVersionThe version of the card's software.ro
LumVersionString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.5
lumCardSerialNumberThe card's Serial Number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4614.1.1.2.1.1.6
lumCardCleiCodeThe cards CLEI code.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4614.1.1.2.1.1.7
lumCardLEDsEach byte is a LED. 1 - off; 2 - on;ro
OCTET STRING
.1.3.6.1.4.1.4614.1.1.2.1.1.8
lumCardOperStateThe Operational State indicates the current state of the cardro
LumCardOperState (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.9
lumCardAdminStateThis object indicates the state transition desired by the management. Below are the valid values that SNMP Manager can set, depending on lumCardType: lumCardType lumCardAdminState SET request =========== ============================= syscon(2) switchover(7) ring(3) switchover(7) t1(4) active(1), standby(2), outOfService(4), reset(6), switchover(7) ether(5) active(1), standby(2), outOfService(4), reset(6) Other values set by SNMP Manager for the cards above, or any value set for other cards will be rejected by SNMP Agent.rw
LumCardAdminState (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.10
lumCardFailureStateFailure state of the card.ro
LumCardFailureState (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.11
lumCardNumbOfPortsThe total number of ports on this card.ro
Unsigned32
.1.3.6.1.4.1.4614.1.1.2.1.1.12
lumCardVoltageThe current card voltage as measured by the voltage sensors.ro
Unsigned32
.1.3.6.1.4.1.4614.1.1.2.1.1.13
lumCardTemperatureThe current card temperature as measured by the temperature sensors.ro
Unsigned32
.1.3.6.1.4.1.4614.1.1.2.1.1.14
lumCardCPUtilizationThe cards main CPU utilization in percents. Its expected that this field may oscilate and should not be taken for granted. When CPU utilization reaches 100%, the card may have no spare CPU cycles to actually report it.ro
LumPercent (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.15
lumCardNVMemoryAvailableThe currently available to use part of the non-volatile memory.ro
Unsigned32
.1.3.6.1.4.1.4614.1.1.2.1.1.16
lumCardNVMemoryUsedThe currently unavailable part of the non-volatile memory.ro
Unsigned32
.1.3.6.1.4.1.4614.1.1.2.1.1.17
lumCardUpTimeTime of the last reboot relative to SYSCON sysUpTime.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.4614.1.1.2.1.1.18
lumStandbySlotThe slot number of the card that serves as a standby for this card. SNMP Manager must set a desired card to standby state before attempting to set lumStandbySlot object's instance to to the value of that's slot.rw
LumSlotNum (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.19
lumCardFlashImage1VerThe version number of the flash image #1.ro
LumVersionString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.20
lumCardFlashImage2VerThe version number of the flash image #2.ro
LumVersionString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.21
lumCardFlashImage3VerThe version number of the flash image #3.ro
LumVersionString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.22
lumCardFlashImage1StateThe state of the flash image #1.ro
LumImageState (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.23
lumCardFlashImage2StateThe state of the flash image #2.ro
LumImageState (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.24
lumCardFlashImage3StateThe version number of the flash image #3.ro
LumImageState (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.25
lumCardResetInProgressThe card reset indicator.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4614.1.1.2.1.1.26
lumCardPROMVersionThe version of the PROM on this card.ro
LumVersionString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.27
lumCardManufDateAndLocationThe date and location where the card has been manufactured.ro
LumManufactureString (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.28
lumCardCPULast2SecondsThe cards main CPU utilization during the last two seconds in percents multiplied by hundred.ro
LumPercent (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.29
lumCardCPULast1MinuteThe cards main CPU utilization during the last one minute in percents multiplied by hundred.ro
LumPercent (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.30
lumCardCPULast10MinutesThe cards main CPU utilization during the last ten minutes in percents multiplied by hundred.ro
LumPercent (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.31
lumCardTotalRAMMemoryThe total RAM memory on this card in bytes.ro
Unsigned32
.1.3.6.1.4.1.4614.1.1.2.1.1.32
lumCardRAMMemoryUsedThe RAM memory used on this card in bytes.ro
Unsigned32
.1.3.6.1.4.1.4614.1.1.2.1.1.33
lumCardBaseTypeThe base type of a card in the slot.ro
LumCardBaseType (LUMINOUS-TC-MIB)
.1.3.6.1.4.1.4614.1.1.2.1.1.34