LUMINOUS-SHELF-MIB
AI MIB Summary
The LUMINOUS-SHELF-MIB provides SNMP management capabilities for Luminous optical shelf hardware, exposing metrics for shelf status, port states, and line card inventory. It enables the monitoring of physical layer components and environmental sensors specific to Luminous optical transport equipment.
The Luminous Shelf MIB contains Information related to the equipment contained in Luminous Shelf.
Main OID:
lumADMShelfMIB.1.3.6.1.4.1.4614.1.1
57
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
57 total| Object Name |
|---|
luminous OBJECT IDENTIFIER .1.3.6.1.4.1.4614 |
lumADM OBJECT IDENTIFIER .1.3.6.1.4.1.4614.1 |
lumADMShelfMIBThe Luminous Shelf MIB contains
Information related to the
equipment contained in Luminous
Shelf. MODULE-IDENTITY .1.3.6.1.4.1.4614.1.1 |
lumADMShelf OBJECT IDENTIFIER .1.3.6.1.4.1.4614.1.1.1 |
lumNodeIdUsed to identify the node.ro Integer32 .1.3.6.1.4.1.4614.1.1.1.1 |
lumShelfIdShelf IDro OCTET STRING .1.3.6.1.4.1.4614.1.1.1.2 |
lumNodeTypeA Central Office(CO) or Customer Premise Equipment(CPE).
CO nodes act as timing sources for the ring.rw Enumeration .1.3.6.1.4.1.4614.1.1.1.3 |
lumShelfTypeLMS shelf type. This object may be used
to identify Luminous shelves/nodes types.ro LumShelfType (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.1.4 |
lumShelfHWVersionThe Shelf Hardware Version.ro LumVersionString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.1.5 |
lumShelfSerialNumberLuminous assigned Shelf Serial Numberro LumSerialNumString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.1.6 |
lumShelfCleiCodeThe CLEI code of the shelf.ro LumCleiString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.1.7 |
lumShelfManufactureDateThe date this shelf has been manufactured.ro LumManufactureString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.1.8 |
lumNodeStatusminorAlarm(2) indicates that no action is
needed but some alarming event has happened.
minorFailure(3) indicates that a fault has
occured but does not persist. The action
from the management may not be needed.
criticalFailure(4) indicates that
the shelf cannot function properly.
The management action is recommended
(can be even reset or, if mulfunctioning,
be replace) to correct the problem.
Otherwise the problem may persist.
This field is only an indication to the
management of the failure/alarm occured.
The management may decide to discover the
route cause of the problem by analizing
MIB objects on this and other shelves.ro Enumeration .1.3.6.1.4.1.4614.1.1.1.9 |
lumShelfChangesNumber of shelf changes such
as card inserts/removes, switchovers,
downloads (i.e. ones resulting
in traps) since the last reboot.ro Counter32 .1.3.6.1.4.1.4614.1.1.1.10 |
lumShelfCommandreset (2) - resets the shelf.rw Enumeration .1.3.6.1.4.1.4614.1.1.1.11 |
lumPrimaryOptinetClockSourcePortifIndex of the port desired to be used as as a primary
optinet clock source. Can be set on CO nodes only.rw Integer32 .1.3.6.1.4.1.4614.1.1.1.12 |
lumSecondaryOptinetClockSourcePortifIndex of the port desired to be used as as a secondary
optinet clock source. Can be set on CO nodes only.rw Integer32 .1.3.6.1.4.1.4614.1.1.1.13 |
lumCurrentOptinetClockSourcePortThe current source of the optinet clock.
primary(3),
secondary(4)
can be reported only on CO nodes, and indicate
which clock source has been currently selected
by this CO node.
clockWise(5),
counterClockWise(6)
can be reported only on CPE nodes and indicate
the ring direction to the closest CO node from
where the clock source is taken.
none(1)
indicates that the clock source has not been chosen.
internal(2)
indicates a node using its internal oscillator
for a clock source. The internal oscillator is
an oven-controlled oscillator (OCXO)
on the switch(ring) card.ro Enumeration .1.3.6.1.4.1.4614.1.1.1.14 |
lumShelfCurrentTimeThe current date and time on this shelf.ro LumDateTimeString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.1.15 |
lumSyncTypeThis control the behaviour of the timing synchronisation for
this node.rw Enumeration .1.3.6.1.4.1.4614.1.1.1.16 |
lumADMCard OBJECT IDENTIFIER .1.3.6.1.4.1.4614.1.1.2 |
lumADMCardTableLuminous Card Table. SEQUENCE OF LumADMCardEntry .1.3.6.1.4.1.4614.1.1.2.1 |
lumADMCardEntry. LumADMCardEntry .1.3.6.1.4.1.4614.1.1.2.1.1 |
lumShelfPlaneEither front or back plane.ro LumChassisPlane (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.1 |
lumSlotIDStarts with 1 for the both front plane
and for the back plane. The second
slot of the double-slot cards is
reported as with lumCardType equal to
none(1).ro LumSlotNum (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.2 |
lumCardTypeThe type of a card in the slot.
none(1)indicates that
the card is either not present
in the slot.
present(38)indicates that
the card is present but not
responding.
In order to pre-allocate a slot
for a particular card type, an
SNMP Manager must change the value
of a lumCardType object instance
from the value of none(1) to the
desired value.rw LumCardType (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.3 |
lumCardHWVersionThe version of the card's hardware.ro LumVersionString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.4 |
lumCardSWVersionThe version of the card's software.ro LumVersionString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.5 |
lumCardSerialNumberThe card's Serial Number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4614.1.1.2.1.1.6 |
lumCardCleiCodeThe cards CLEI code.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4614.1.1.2.1.1.7 |
lumCardLEDsEach byte is a LED. 1 - off; 2 - on;ro OCTET STRING .1.3.6.1.4.1.4614.1.1.2.1.1.8 |
lumCardOperStateThe Operational State indicates the
current state of the cardro LumCardOperState (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.9 |
lumCardAdminStateThis object indicates the state transition
desired by the management.
Below are the valid values that SNMP Manager
can set, depending on lumCardType:
lumCardType lumCardAdminState SET request
=========== =============================
syscon(2) switchover(7)
ring(3) switchover(7)
t1(4) active(1), standby(2),
outOfService(4), reset(6),
switchover(7)
ether(5) active(1), standby(2),
outOfService(4), reset(6)
Other values set by SNMP Manager for the
cards above, or any value set for other cards
will be rejected by SNMP Agent.rw LumCardAdminState (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.10 |
lumCardFailureStateFailure state of the card.ro LumCardFailureState (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.11 |
lumCardNumbOfPortsThe total number of ports on this card.ro Unsigned32 .1.3.6.1.4.1.4614.1.1.2.1.1.12 |
lumCardVoltageThe current card voltage as
measured by the voltage sensors.ro Unsigned32 .1.3.6.1.4.1.4614.1.1.2.1.1.13 |
lumCardTemperatureThe current card temperature as
measured by the temperature sensors.ro Unsigned32 .1.3.6.1.4.1.4614.1.1.2.1.1.14 |
lumCardCPUtilizationThe cards main CPU utilization in percents.
Its expected that this field may oscilate
and should not be taken for granted.
When CPU utilization reaches 100%, the
card may have no spare CPU cycles to
actually report it.ro LumPercent (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.15 |
lumCardNVMemoryAvailableThe currently available to use
part of the non-volatile memory.ro Unsigned32 .1.3.6.1.4.1.4614.1.1.2.1.1.16 |
lumCardNVMemoryUsedThe currently unavailable
part of the non-volatile memory.ro Unsigned32 .1.3.6.1.4.1.4614.1.1.2.1.1.17 |
lumCardUpTimeTime of the last reboot relative
to SYSCON sysUpTime.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.4614.1.1.2.1.1.18 |
lumStandbySlotThe slot number of the card that
serves as a standby for this
card. SNMP Manager must set a
desired card to standby state before
attempting to set lumStandbySlot
object's instance to to the
value of that's slot.rw LumSlotNum (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.19 |
lumCardFlashImage1VerThe version number of the flash image #1.ro LumVersionString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.20 |
lumCardFlashImage2VerThe version number of the flash image #2.ro LumVersionString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.21 |
lumCardFlashImage3VerThe version number of the flash image #3.ro LumVersionString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.22 |
lumCardFlashImage1StateThe state of the flash image #1.ro LumImageState (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.23 |
lumCardFlashImage2StateThe state of the flash image #2.ro LumImageState (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.24 |
lumCardFlashImage3StateThe version number of the flash image #3.ro LumImageState (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.25 |
lumCardResetInProgressThe card reset indicator.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4614.1.1.2.1.1.26 |
lumCardPROMVersionThe version of the PROM on this card.ro LumVersionString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.27 |
lumCardManufDateAndLocationThe date and location where the
card has been manufactured.ro LumManufactureString (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.28 |
lumCardCPULast2SecondsThe cards main CPU utilization during the last
two seconds in percents multiplied by hundred.ro LumPercent (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.29 |
lumCardCPULast1MinuteThe cards main CPU utilization during the last
one minute in percents multiplied by hundred.ro LumPercent (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.30 |
lumCardCPULast10MinutesThe cards main CPU utilization during the last
ten minutes in percents multiplied by hundred.ro LumPercent (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.31 |
lumCardTotalRAMMemoryThe total RAM memory on this card in bytes.ro Unsigned32 .1.3.6.1.4.1.4614.1.1.2.1.1.32 |
lumCardRAMMemoryUsedThe RAM memory used on this card in bytes.ro Unsigned32 .1.3.6.1.4.1.4614.1.1.2.1.1.33 |
lumCardBaseTypeThe base type of a card in the slot.ro LumCardBaseType (LUMINOUS-TC-MIB) .1.3.6.1.4.1.4614.1.1.2.1.1.34 |