Home/Catalog/LINKB-OPT-FDDI-MIB-1-1-2

LINKB-OPT-FDDI-MIB-1-1-2

AI MIB Summary

Standard SNMP MIB module defining data structures for LINKB-OPT-FDDI-MIB-1-1-2.

69
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

69 total
Object Name
a3Com
OBJECT IDENTIFIER
.1.3.6.1.4.1.43
RFC1155-SMI
Unknown
.1.3.6.1.4.1.43
lb3gh
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.7
lb3ghOptFddi
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.7.2
lbOptSMTHoldConditionGenerated when fddiSMTHoldState (fddimibSMTHoldState) assumes the state holding-prm or holding-sec. This notification is a Condition in the Status Report Protocol (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.1
lbOptSMTPeerWrapConditionThis condition is active when fddiSMTPeerWrapFlag (fddimibSMTPeerWrapFlag) is set. This notification is a Condition in the Status Report Protocol (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.2
lbOptMACDuplicateAddressConditionThis condition is active when either fddiMACDA-Flag (fddimibMACDaFlag) or fddiMACUNDA-Flag (fddimibMACUnaDaFlag) is set. This event is handled as a Condition in the Status Report Protocol (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.3
lbOptMACFrameErrorConditionGenerated when the fddiMACFrameErrorRatio (fddimibMACFrameErrorRatio) is greater than or equal to fddiMACFrameErrorThreshold (fddimibMACFrameErrorThreshold). This event is handled as a Condition in the Status Report Protocol (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.4
lbOptMACNotCopiedConditionGenerated when the fddiMACNotCopiedRatio (fddimibMACNotCopiedRatio) is greater than or equal to the fddiMACNotCopiedThreshold (lbOptMACNotCopiedThreshold). This event is handled as a Condition in the Status Report Protocol (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.5
lbOptMACNeighborChangeEventGenerated when a change in a MAC's upstream neighbor address or downstream neighbor address is detected. (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.6
lbOptMACPathChangeEventThis event is generated when the value of the fddiMACCurrentPath (fddimibMACCurrentPath) changes. This event shall be supressed if the value changes from isolated to local or local to isolated (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.7
lbOptPORTLerConditionThis condition becomes active when the value of fddiPORTLer-Estimate (fddimibPORTLerEstimate) is less than or equal to fddiPORTLer-Alarm (fddimibPORTLerAlarm). This will be reported with the Status Report Frames (SRF) (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.8
lbOptPORTUndesiredConnAttemptEventGenerated when an undesired connection attempt has been made (see 5.2.4, 7.2.7, and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.9
lbOptPORTEBErrorConditionGenerated when the Elasticity Buffer Error-Ct (lbOptPORTEBErrorCt) increments. This is handled as a condition in the Status Report Protocol. It is generated when an increment occurs in the station's sampling period (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.10
lbOptPORTPathChangeEventThis event is generated when the value of the fddiPORTCurrentPath (lbOptPORTCurrentPath) changes. This event shall be surpressed if the value changes from isolated to local or local to isolated (see 7.2.7 and 8.3).
TRAP-TYPE
.1.3.6.1.4.1.43.7.2.0.11
lbOptSMT
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.7.2.1
lbOptSMTTableA list of optional SMT entries. The number of entries shall not exceed the value of snmpFddiSMTNumber.
SEQUENCE OF LbOptSMTEntry
.1.3.6.1.4.1.43.7.2.1.1
lbOptSMTEntryAn optional SMT entry containing information common to a given optional SMT.
LbOptSMTEntry
.1.3.6.1.4.1.43.7.2.1.1.1
lbOptSMTIndexA unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.ro
INTEGER
.1.3.6.1.4.1.43.7.2.1.1.1.1
lbOptSMTManufacturerOUIThe three octets of manufacturer data which make up the manufacturerOUI component.ro
OCTET STRING
.1.3.6.1.4.1.43.7.2.1.1.1.2
lbOptSMTManufacturerDataThe 29 octets of manufacturer data which make up the manufacturerData component.ro
OCTET STRING
.1.3.6.1.4.1.43.7.2.1.1.1.3
lbOptSMTHoldStateThis variable indicates the current state of the Hold function. The value 'not-holding' is the default and initial value. The value must be set to 'not-holding' as part of Active_Actions and when the conditions causing 'holding-prm' or 'holding-sec' are no longer true. The value 'holding-prm' must be set when the condition (notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail | TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is satisfied in state PC8:ACTIVE for the A Port. The value 'holding-sec' must be set when the condition (notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail | TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is satisfied in state PC8:ACTIVE for the B Port.ro
Enumeration
.1.3.6.1.4.1.43.7.2.1.1.1.4
lbOptSMTSetCountThis variable is composed of a count incremented in response to a Set operation on the MIB, and the time of the change, however only the count is reported here (refer to ANSI SMT 8.4.1).ro
INTEGER
.1.3.6.1.4.1.43.7.2.1.1.1.5
lbOptSMTLastSetStationIdThe Station ID of the station that effected the last change in the FDDI MIB.ro
FddiSMTStationIdType
.1.3.6.1.4.1.43.7.2.1.1.1.6
lbOptMAC
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.7.2.2
lbOptMACBridgeFunctionTableA list of MAC bridge function entries.
SEQUENCE OF LbOptMACBridgeFunctionEntry
.1.3.6.1.4.1.43.7.2.2.1
lbOptMACBridgeFunctionEntryBridge function information for a given MAC within a given SMT.
LbOptMACBridgeFunctionEntry
.1.3.6.1.4.1.43.7.2.2.1.1
lbOptMACBridgeFunctionSMTIndexA unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.ro
INTEGER
.1.3.6.1.4.1.43.7.2.2.1.1.1
lbOptMACBridgeFunctionMACIndexIndex variable for uniquely identifying the MAC object instances.ro
INTEGER
.1.3.6.1.4.1.43.7.2.2.1.1.2
lbOptMACBridgeFunctionsIndicates the MAC's optional bridging functions. The Value -1 is used to indicate that bridging is not supported by this MAC. The value is a sum. This value initially takes the value zero, then for each function present, 2 raised to a power is added to the sum. The powers are according to the following table: Function Power tb 0 sr 1 srt 2ro
INTEGER (-1..7)
.1.3.6.1.4.1.43.7.2.2.1.1.3
lbOptMACTPriTableA list of MAC T-Pri entries.
SEQUENCE OF LbOptMACTPriEntry
.1.3.6.1.4.1.43.7.2.2.2
lbOptMACTPriEntryA collection of T-Pri information for a given MAC within a given SMT.
LbOptMACTPriEntry
.1.3.6.1.4.1.43.7.2.2.2.1
lbOptMACTPriSMTIndexA unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.ro
INTEGER
.1.3.6.1.4.1.43.7.2.2.2.1.1
lbOptMACTPriMACIndexIndex variable for uniquely identifying the MAC object instances.ro
INTEGER
.1.3.6.1.4.1.43.7.2.2.2.1.2
lbOptMACTPri0This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units.ro
FddiTimeNano
.1.3.6.1.4.1.43.7.2.2.2.1.3
lbOptMACTPri1This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units.ro
FddiTimeNano
.1.3.6.1.4.1.43.7.2.2.2.1.4
lbOptMACTPri2This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units.ro
FddiTimeNano
.1.3.6.1.4.1.43.7.2.2.2.1.5
lbOptMACTPri3This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units.ro
FddiTimeNano
.1.3.6.1.4.1.43.7.2.2.2.1.6
lbOptMACTPri4This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units.ro
FddiTimeNano
.1.3.6.1.4.1.43.7.2.2.2.1.7
lbOptMACTPri5This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units.ro
FddiTimeNano
.1.3.6.1.4.1.43.7.2.2.2.1.8
lbOptMACTPri6This attribute is an unsigned twos-complement T_pri threshold as described in the MAC standard converted to non-twos-complement form and reported in 1 ns units.ro
FddiTimeNano
.1.3.6.1.4.1.43.7.2.2.2.1.9
lbOptPATH
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.7.2.3
lbOptPATHRingTableA list of PATH ring entries.
SEQUENCE OF LbOptPATHRingEntry
.1.3.6.1.4.1.43.7.2.3.1
lbOptPATHRingEntryRing latency, trace status, and T-Rmode information for a given PATH within a given SMT.
LbOptPATHRingEntry
.1.3.6.1.4.1.43.7.2.3.1.1
lbOptPATHRingSMTIndexA unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.ro
INTEGER
.1.3.6.1.4.1.43.7.2.3.1.1.1
lbOptPATHRingPATHIndexIndex variable for uniquely identifying the primary, secondary and local PATH object instances. Local PATH object instances are represented with integer values 3 to 255.ro
INTEGER
.1.3.6.1.4.1.43.7.2.3.1.1.2
lbOptPATHRingLatencyGives the total accumulated latency of the ring associated with this path. May be measured directly by the station or calculated by a management station. Values of this object are reported in 1 ns units.rw
FddiTimeNano
.1.3.6.1.4.1.43.7.2.3.1.1.3
lbOptPATHTraceStatusThis attribute indicates the current trace status of the path. The value is a sum which represents all of the trace status information which applies. This value initially takes the value zero, then for each condition which applies, 2 raised to a power is added to the sum. the powers are according to the following table: TraceStatus Power traceinitiated 0 tracepropragated 1 traceterminated 2 tracetimeout 3ro
INTEGER
.1.3.6.1.4.1.43.7.2.3.1.1.4
lbOptPATHT-RmodeUsed by RMT to limit the duration of restricted dialogs on a path. This object is reported in 1 ns units.rw
FddiTimeNano
.1.3.6.1.4.1.43.7.2.3.1.1.5
lbOptPATHSbaTableA list of PATH Sba entries.
SEQUENCE OF LbOptPATHSbaEntry
.1.3.6.1.4.1.43.7.2.3.2
lbOptPATHSbaEntrySba information for a given PATH within a given SMT.
LbOptPATHSbaEntry
.1.3.6.1.4.1.43.7.2.3.2.1
lbOptPATHSbaSMTIndexA unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.ro
INTEGER
.1.3.6.1.4.1.43.7.2.3.2.1.1
lbOptPATHSbaPATHIndexIndex variable for uniquely identifying the primary, secondary and local PATH object instances. Local PATH object instances are represented with integer values 3 to 255.ro
INTEGER
.1.3.6.1.4.1.43.7.2.3.2.1.2
lbOptPATHSbaPayloadThe payload portion of the Synchronous Bandwidth Allocation for thi path. This value represents the maximum number of bytes of data allocated for transmission per 125 microseconds.rw
INTEGER
.1.3.6.1.4.1.43.7.2.3.2.1.3
lbOptPATHSbaOverheadThe overhead portion of the Synchronous Bandwith Allocation for this path. This value repersents the maximum number of bytes overhead (token capture, frame header, etc.) used pre negotiated Target Token Rotation Time (T_neg).rw
INTEGER
.1.3.6.1.4.1.43.7.2.3.2.1.4
lbOptPATHSbaAvailableThis value is the maximum Synchronous Bandwith available for a path in bytes per second.rw
INTEGER
.1.3.6.1.4.1.43.7.2.3.2.1.5
lbOptPORT
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.7.2.4
lbOptPORTTableA list of optional PORT entries.
SEQUENCE OF LbOptPORTEntry
.1.3.6.1.4.1.43.7.2.4.1
lbOptPORTEntryMAC loop time and EB error count information for a given PORT within a given SMT.
LbOptPORTEntry
.1.3.6.1.4.1.43.7.2.4.1.1
lbOptPORTSMTIndexA unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.ro
INTEGER
.1.3.6.1.4.1.43.7.2.4.1.1.1
lbOptPORTIndexIndex variable for uniquely identifying the PORT object instances.ro
INTEGER
.1.3.6.1.4.1.43.7.2.4.1.1.2
lbOptPORTMACLoopTimeThis attribute controls the value used for T_Next(9) (see 9.4.4.2.3). This object is reported in 1 ns units.rw
FddiTimeNano
.1.3.6.1.4.1.43.7.2.4.1.1.3
lbOptPORTEBErrorCtA count that should as closely as possible match the times an Elasticity Buffer Error has occurred while in active line state.ro
Counter
.1.3.6.1.4.1.43.7.2.4.1.1.4
lbOptPORTLSTableA list of optional PORT line state entries.
SEQUENCE OF LbOptPORTLSEntry
.1.3.6.1.4.1.43.7.2.4.2
lbOptPORTLSEntryMaintenance line state and PC line state information for a given PORT within a given SMT.
LbOptPORTLSEntry
.1.3.6.1.4.1.43.7.2.4.2.1
lbOptPORTLSSMTIndexA unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.ro
INTEGER
.1.3.6.1.4.1.43.7.2.4.2.1.1
lbOptPORTLSPORTIndexIndex variable for uniquely identifying the PORT object instances.ro
INTEGER
.1.3.6.1.4.1.43.7.2.4.2.1.2
lbOptPORTMaintLSThe PORT Maintenance Line State specifies the line state (Maint_LS) to be transmitted when the PCM state machine for the port is in state PC9 Maint.rw
Enumeration
.1.3.6.1.4.1.43.7.2.4.2.1.3
lbOptPORTPCLSThis attribute indicates the line state (PC_LS) received by the port.ro
Enumeration
.1.3.6.1.4.1.43.7.2.4.2.1.4
LINKB-OPT-FDDI-MIB-1-1-2 - SNMP MIB Reference | MIBs Explorer