Home/Catalog/LEFTHAND-NETWORKS-NSM-STORAGE-MIB

LEFTHAND-NETWORKS-NSM-STORAGE-MIB

AI MIB Summary

The LEFTHAND-NETWORKS-NSM-STORAGE-MIB enables SNMP-based monitoring of HP StorageWorks P4000 (LeftHand) SAN storage arrays, exposing critical operational metrics including node health status, volume capacity utilization, I/O throughput statistics, and cluster membership states.

HP StorageWorks P4000 Storage Information
Main OID:
lhnNsmStorageModule.1.3.6.1.4.1.9804.2.1.5
76
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

76 total
Object Name
lhnNsmStorageModuleHP StorageWorks P4000 Storage Information
MODULE-IDENTITY
.1.3.6.1.4.1.9804.2.1.5
lhnNsmStorageModuleConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9804.2.1.5.1
lhnNsmStorageModuleCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9804.2.1.5.1.1
lefthandNetworksNsmStorageMibComplianceThe compliance statement.
Unknown
.1.3.6.1.4.1.9804.2.1.5.1.1.1
lhnNsmStorageModuleGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9804.2.1.5.1.2
lefthandNetworksNsmStorageGroupThe default group for all NSM Storage objects.
Unknown
.1.3.6.1.4.1.9804.2.1.5.1.2.1
lefthandNetworksNsmStorageGroupObsoleteThe group for all obsolete NSM Storage objects.obsolete
Unknown
.1.3.6.1.4.1.9804.2.1.5.1.2.2
storageDeviceCountThe number of storage devices.ro
Integer32
.1.3.6.1.4.1.9804.3.1.1.2.4.1
storageDeviceTableA table of storage devices for the NSM. The number of devices is given by storageDeviceCount.
SEQUENCE OF StorageDeviceEntry
.1.3.6.1.4.1.9804.3.1.1.2.4.2
storageDeviceEntryA row of storage device information.
StorageDeviceEntry
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1
storageDeviceIndexThe index for the storageDeviceTable table.
Unsigned32
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.1
storageDeviceModelThe device model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.2
storageDeviceClassThe device class describes the interface type and speed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.3
storageDeviceCapacityInBytesThe capacity of the device. Obsolete in SAN/iQ 8.5. Use 'storageDeviceCapacity'.roobsolete
CounterBasedGauge64 UNITS "Blocks (512 bytes)"
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.4
storageDeviceModeThe device mode. Posible modes are: active, inactive, hot spare, rebuilding, uninitialized, foreignro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.5
storageDeviceChainThe storage device chain. Obsolete in SAN/iQ 8.5.roobsolete
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.6
storageDeviceSerialNumberThe device serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.7
storageDeviceTemperatureThe device temperature.ro
Gauge32 UNITS "Celsius"
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.9
storageDeviceTemperatureCriticalThe value where the temperature becomes critical.ro
Integer32 UNITS "Celsius"
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.10
storageDeviceTemperatureLimitThe maximum temperature that can be tolerated.ro
Integer32 UNITS "Celsius"
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.11
storageDeviceTemperatureStatusThe device temperature status.ro
Enumeration
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.12
storageDeviceLabelThe the device bay/slot label.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.13
storageDeviceNameThe device name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.14
storageDeviceRaidDeviceThe RAID device LUN for the storage device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.15
storageDeviceFirmwareVersionThe device firmware version.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.16
storageDeviceSmartHealthThe device SMART health status. Possible values are: normal, marginal, faultyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.17
storageDeviceSmartHealthStatusThe device SMART health status.ro
Enumeration
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.18
storageDeviceCapacityThe capacity of the device.ro
Integer32 UNITS "MB"
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.19
storageDeviceHotRemovableThe hot removable status of the device.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.20
storageDeviceStateThe device (presence) state. Possible values are: on_and_secured, off_and_secured, off_or_removedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.90
storageDeviceStatusThe device status.ro
Enumeration
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.91
storageDeviceRowStatusThe table row status. Obsolete in SAN/iQ 8.5.roobsolete
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.99
storageRaidCountThe number of RAID devices (controllers).ro
Integer32
.1.3.6.1.4.1.9804.3.1.1.2.4.3
storageRaidTableA table of RAID devices (controllers) for the NSM. The number of devices is given by storageRaidCount.
SEQUENCE OF StorageRaidEntry
.1.3.6.1.4.1.9804.3.1.1.2.4.4
storageRaidEntryA row of RAID device (controller) information.
StorageRaidEntry
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1
storageRaidIndexThe index for the storageRAIDTable table.
Unsigned32
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.1
storageRaidDeviceNameThe RAID device (controller) name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.2
storageRaidLevelThe RAID level.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.3
storageRaidDiskCountThe number of storage devices this RAID device (controller) has.ro
Integer32
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.4
storageRaidSpareDiskCountThe number of spare disks the RAID (controller) has.roobsolete
Integer32
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.5
storageRaidSuperBlockThe RAID device (controller) spare super block status. Obsolete in SAN/iQ 8.5.roobsolete
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.6
storageRaidChunkSizeThe RAID device (controller) chunk size. Obsolete in SAN/iQ 8.5.roobsolete
Integer32 UNITS "Kbytes"
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.7
storageRaidDisksThe RAID device (controller) disk list.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.8
storageRaidDeviceThe LUN for the RAID device (controller).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.9
storageRaidDeviceCapacityThe capacity of the RAID device (controller.)ro
Integer32 UNITS "MB"
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.10
storageRaidDeviceParityInitStateThe RAID device (controller) parity initilization status. Possible values: normal, rebuilding, degradedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.11
storageRaidRebuildPercentThe RAID device (controller) rebuild percent complete.ro
Gauge32 UNITS "%"
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.12
storageRaidRebuildTimeThe RAID device (controller) rebuild time remaining.ro
Gauge32 UNITS "minutes"
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.13
storageRaidDeviceStateThe RAID device (controller) state. Possible values are: normal, rebuilding, degradedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.90
storageRaidDeviceStatusThe RAID device (Controller) status.ro
Enumeration
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.91
storageRaidDeviceRowStatusThe table row status. Obsolete in SAN/iQ 8.5.roobsolete
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.4.1.99
storageRaidDescriptionA description of the RAID configuration.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.5
storageRaidModeThe RAID mode.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.7
storageRaidCapacityThe capacity available for SAN storage.ro
Integer32 UNITS "MB"
.1.3.6.1.4.1.9804.3.1.1.2.4.8
storageRaidStatusThe RAID status.ro
Enumeration
.1.3.6.1.4.1.9804.3.1.1.2.4.11
storageRaidStateThe system RAID state. Possible values are: normal, rebuilding, degradedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.12
storageRaidMinimumSpeedThe minimum RAID rebuild speed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.13
storageRaidMaximumSpeedThe maximum RAID rebuild speed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.14
storageRaidParityInitStateThe RAID parity initilization status. Obsolete in SAN/iQ 8.5. Replaced with storageRaidDeviceParityInitState.roobsolete
Enumeration
.1.3.6.1.4.1.9804.3.1.1.2.4.15
storageRaidStatsIOsReadA counter of IO read operations on the NSM.ro
Counter64 UNITS "operations"
.1.3.6.1.4.1.9804.3.1.1.2.4.16
storageRaidStatsIOsWriteA counter of IO write operations on the NSM.ro
Counter64 UNITS "operations"
.1.3.6.1.4.1.9804.3.1.1.2.4.17
storageRaidStatsKbytesReadThe number of kB read from the NSM.ro
Counter64 UNITS "kB"
.1.3.6.1.4.1.9804.3.1.1.2.4.19
storageRaidStatsKbytesWriteThe number of kB written to the NSM.ro
Counter64 UNITS "kB"
.1.3.6.1.4.1.9804.3.1.1.2.4.20
storageRaidStatsQDepthTotalThe number of pending read and write operations on the NSM.ro
Gauge32 UNITS "operations"
.1.3.6.1.4.1.9804.3.1.1.2.4.22
storageRaidStatsIoLatencyReadThe total time spent waiting for read operations to complete on the NSM.ro
Counter64 UNITS "ms"
.1.3.6.1.4.1.9804.3.1.1.2.4.23
storageRaidStatsIoLatencyWriteThe total time spent waiting for write operations to complete on the NSM.ro
Counter64 UNITS "ms"
.1.3.6.1.4.1.9804.3.1.1.2.4.24
storageOsRaidCountThe number of OS RAID devices.ro
Integer32
.1.3.6.1.4.1.9804.3.1.1.2.4.50
storageOsRaidTableA table of OS RAID devices in the system. The number of entries is given by storageOsRaidCount.
SEQUENCE OF StorageOsRaidEntry
.1.3.6.1.4.1.9804.3.1.1.2.4.51
storageOsRaidEntryA row of OS RAID device information.
StorageOsRaidEntry
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1
storageOsRaidIndexThe index for the storageOsRaidTable table.
Unsigned32
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1.1
storageOsRaidNameThe OS RAID name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1.2
storageOsRaidDeviceThe LUN for the OS RAID.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1.3
storageOsRaidModeThe OS RAID mode.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1.4
storageOsRaidSizeThe OS RAID size.ro
Integer32 UNITS "MB"
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1.5
storageOsRaidStateThe OS RAID state.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1.90
storageOsRaidRowStatusThe table row status. Obsolete in SAN/iQ 8.5.roobsolete
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9804.3.1.1.2.4.51.1.99

More MIBs from LeftHand

Browse all LeftHandMIBs →
LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB

The LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB monitors the operational status, node health, and quorum states of HP StorageWorks P4000 (LeftHand) SAN cluster groups via SNMP. It provides visibility into critical cluster metrics including node membership, service availability, and failover conditions to ensure storage array redundancy and data integrity.

312 objects→
LEFTHAND-NETWORKS-NUS-COMMON-CLUSTERING-MIB

The LEFTHAND-NETWORKS-NUS-COMMON-CLUSTERING-MIB provides SNMP access to cluster state variables, node synchronization status, and failover metrics for LeftHand Networks (HPE StoreVirtual) NSM devices. It enables monitoring of cluster membership, quorum health, and replication consistency to ensure high availability within the storage virtualization environment.

146 objects→
LEFTHAND-NETWORKS-NSM-INFO-MIB

LEFTHAND-NETWORKS-NSM-INFO-MIB provides SNMP access to operational status, configuration parameters, and performance counters for HP StorageWorks P4000 (LeftHand) SAN storage arrays. This module enables the monitoring of cluster health, node availability, volume states, and storage subsystem metrics essential for infrastructure management.

141 objects→
LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB

The LEFTHAND-NETWORKS-NSM-NOTIFICATION-MIB defines SNMP trap and inform message structures for HP StorageWorks P4000 SAN arrays to alert management systems on critical storage subsystem events. These notifications specifically convey state changes and fault conditions, such as controller failures, volume status transitions, and hardware component alerts, enabling automated incident response for the P4000 storage environment.

103 objects→
LEFTHAND-NETWORKS-NSM-SECURITY-MIB

The LEFTHAND-NETWORKS-NSM-SECURITY-MIB monitors security-related events, access control states, and authentication logs on HP StorageWorks P4000 (LeftHand) SAN storage arrays. It provides SNMP-trappable data for auditing user access attempts, policy violations, and system security status within the LeftHand Storage Management environment.

55 objects→
LEFTHAND-NETWORKS-NUS-COMMON-SECURITY-MIB

The LEFTHAND-NETWORKS-NUS-COMMON-SECURITY-MIB module enables monitoring and management of security-related attributes, including authentication states, access control lists, and audit logs, specifically for Left Hand Networks (now part of HP) NUS storage appliances. It facilitates the retrieval of SNMP-trap notifications and variable bindings related to security policy enforcement and system integrity checks within the NUS storage environment.

49 objects→