LEA-SMART-SPLITTER-MIB
AI MIB Summary
The LEA-SMART-SPLITTER-MIB facilitates the monitoring and configuration of LEA Smart Splitter hardware devices, specifically tracking optical splitter port status, signal attenuation levels, and active session counts within passive optical network (PON) infrastructures.
LEA Smart Splitter Management Information Base
Main OID:
leaSmartSplitter.1.3.6.1.4.1.14841.1.1
13
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
13 total| Object Name |
|---|
leaSmartSplitterLEA Smart Splitter Management Information Base MODULE-IDENTITY .1.3.6.1.4.1.14841.1.1 |
splitterRelay OBJECT IDENTIFIER .1.3.6.1.4.1.14841.1.1.1 |
relayActiveDurationDuration that a bypass relay is active in seconds. As a fail-safe mechanism, the relay will automatically return a line back to normal operational mode when this timer has expired. The same relay timer value will be used for every port.rw INTEGER .1.3.6.1.4.1.14841.1.1.1.1 |
numberOfActiveRelaysTotal count of active relays. The agent controls the number of active relays so that the maximum is not exceeded in order to keep power consumption down.ro INTEGER .1.3.6.1.4.1.14841.1.1.1.2 |
heartBeatThis parameter returns a simply acknowledge following a request from the manager.ro Enumeration .1.3.6.1.4.1.14841.1.1.1.3 |
relayTableTable of relay status SEQUENCE OF RelayTableEntry .1.3.6.1.4.1.14841.1.1.1.4 |
relayTableEntryA row describing a relay status RelayTableEntry .1.3.6.1.4.1.14841.1.1.1.4.1 |
relayIndexThe index of the table. Its value is (relaySlot-1)*24+relayPort Integer32 .1.3.6.1.4.1.14841.1.1.1.4.1.1 |
relaySlotThe slot being addressedro Enumeration .1.3.6.1.4.1.14841.1.1.1.4.1.2 |
relayPortThe port being addressedro Enumeration .1.3.6.1.4.1.14841.1.1.1.4.1.3 |
relayStatusThis parameter describes whether a particular POTS line is in a normal or closed loop condition. By setting this parameter, the manager can switch the relays in order to bypass the LPF (Low Pass Filter) for POTS closed loop testing (closed) or force a relay back to normal operation mode before the Relay Active Duration timer times out (normal)rw Enumeration .1.3.6.1.4.1.14841.1.1.1.4.1.4 |
relayResetAllThis parameter would allow the operator to force a relay back to normal operation for all ports.rw Enumeration .1.3.6.1.4.1.14841.1.1.1.5 |
relayChangeNotificationThis notification is sent to the manager after a line status (or relay) change. It takes three parameters : the slot (relaySlot) and port (relayPort) of the line, and its new status (relayStatus)ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.14841.1.1.1.6 |