LC-PHYSICAL-ENTITIES-MIB
AI MIB Summary
The LC-PHYSICAL-ENTITIES-MIB enables SNMP-based monitoring of the physical hardware components, such as chassis slots, power supplies, and fans, for Lancast Managed network devices. It exposes standard physical layer attributes including status, temperature, and operational state to facilitate infrastructure health assessment and fault isolation.
This is the enterprise MIB definition file for the Physical Entities of Lancast Managed products. Copyright 1999 Lancast Inc.
Main OID:
physicalEntities.1.3.6.1.4.1.2745.1.2
139
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
139 total| Object Name |
|---|
tempStatusChangeThis trap will be sent when the temperature falls outside of the exceptable range. The values of chassisEntityIndex, chassisCurrentTemp and chassisMaxTemp will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.11 |
backPlaneFailureThis trap will be sent when there is a backplane failure. The value of modFirstSlot will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.12 |
powerSupply5vChangeThis trap will be sent when the voltage from the 5 volt power supply falls outside of the exceptable range. The values of powerSupplyEntityIndex, powerSupply5vCurrent, powerSupplyMin, powerSupply5vMax and powerSupplyUnitIdentifier will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.13 |
powerSupplyStatusChangeThis trap will be sent when a power supply is either turned on or off. The values of powerSupplyEntityIndex, powerSupplyStatus and powerSupplyUnitIdentifier will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.14 |
powerSupplyInsertionThis trap will be sent when a power supply is inserted. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUnitIdentifier will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.15 |
powerSupplyRemovalThis trap will be sent when a power supply is removed. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUnitIdentifier will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.16 |
chassisEntityResetThis trap is sent when a chassis is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.17 |
moduleEntityResetThis trap is sent when a module is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, modType, modFirstSlot and modNumSlotsOccupied will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.18 |
eportEntityResetThis trap is sent when a port is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, modType, modFirstSlot, modNumSlotsOccupied, and ePortParentRelPos will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.19 |
moduleInsertionThis trap is sent when a module is inserted to a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.20 |
moduleRemovalThis trap is sent when a module is removed from a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.21 |
unknownModuleThis trap is sent when a module is inserted and it's type cannot be determined. The values of modEntityIndex, modType, modFirstSlot, modNumSlotsOccupied will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.22 |
moduleFailureThis trap is sent when a module fails and thus is inaccessible. The value of modFirtSlot will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.23 |
ePortLinkStatusChangeThis trap is sent when there is a change in the link state of a port. The values of ePortLinkStatus, ePortIndex, modType, modFirstSlot, and modNumSlotsOccupied will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.24 |
ePortAdminChangeThis trap is sent when a user changes the admin state of a port from enable to disable or vice versa. The values of ePortAdminState ePortEntityIndex, modType, modFirstSlot, modNumSlotsOccupied, will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.25 |
rtwSwitchOverChangeThis trap is sent when a switchover from the primary to the secondary port and vice versa has occured. The values of rtwEntityIndex, rtwActivePort, modFirstSlot, modNumSlotsOccupied will be included in this traps varBind list. NOTIFICATION-TYPE .1.3.6.1.4.1.2745.1.0.26 |
physicalEntitiesThis is the enterprise MIB definition file for the Physical Entities of Lancast Managed products. Copyright 1999 Lancast Inc. MODULE-IDENTITY .1.3.6.1.4.1.2745.1.2 |
chassisGroup OBJECT IDENTIFIER .1.3.6.1.4.1.2745.1.2.2 |
chassisTableA table of relevent information pertaining to each chassis contained within this system. SEQUENCE OF ChassisTableEntry .1.3.6.1.4.1.2745.1.2.2.1 |
chassisTableEntryAn entry in the table, containing relevant information about a specific chassis contained within this system. ChassisTableEntry .1.3.6.1.4.1.2745.1.2.2.1.1 |
chassisEntityIndexA unique value, the entPhysicalIndex from the entity MIB, which identifies this chassis.ro Integer32 .1.3.6.1.4.1.2745.1.2.2.1.1.1 |
chassisDescriptionA textual string describing a chassis contained within this system.ro DisplayString .1.3.6.1.4.1.2745.1.2.2.1.1.2 |
chassisPartNumberA textual string of the part number assigned to this chassis.ro DisplayString .1.3.6.1.4.1.2745.1.2.2.1.1.3 |
chassisNumSlotsThe number of I/O slots that this chassis supports.ro Integer32 .1.3.6.1.4.1.2745.1.2.2.1.1.4 |
chassisCurrentTempThe temperature of this chassis measured in Celcius degrees. This object will be contained in the tempStatusChange trap,ro Integer32 .1.3.6.1.4.1.2745.1.2.2.1.1.5 |
chassisMaxTempThe maximum temperature for this chassis. If this temperature is exceeded failures may result. This object will be contained in the tempStatusChange Trap,ro Integer32 .1.3.6.1.4.1.2745.1.2.2.1.1.6 |
chassisResetThe trigger to reset this chassis. If the design of this chassis does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable.rw Enumeration .1.3.6.1.4.1.2745.1.2.2.1.1.7 |
lastEntityResetReasonThis object specifies the reason the last reset was applied. This object is included in the entityResetTrap pdu.ro Enumeration .1.3.6.1.4.1.2745.1.2.2.1.1.8 |
lastEntityResetIndexThis object specifies the physical entity index, entPhysicalIndex from the entity MIB, of the last entity that was reset. This object is included in the entityResetTrap pdu.ro Integer32 .1.3.6.1.4.1.2745.1.2.2.1.1.9 |
lastEntityResetTimeThis object specifies the time the last reset was applied to an entity. This object is included in the entityResetTrap pdu.ro DisplayString .1.3.6.1.4.1.2745.1.2.2.1.1.10 |
lastEntityResetTypeThis object specifies the type of entity that was last reset. The values are are a subset from the entity mib entPhysicalClass object.ro Enumeration .1.3.6.1.4.1.2745.1.2.2.1.1.11 |
backPlaneGroup OBJECT IDENTIFIER .1.3.6.1.4.1.2745.1.2.3 |
backPlaneTableA table of relevent information pertaining to a backplane contained within this system. SEQUENCE OF BackPlaneTableEntry .1.3.6.1.4.1.2745.1.2.3.1 |
backPlaneTableEntryAn entry in the table, containing relevant information about a specific backplane contained within this system. BackPlaneTableEntry .1.3.6.1.4.1.2745.1.2.3.1.1 |
backPlaneEntityIndexA unique value, the entPhysicalIndex from the entity MIB, that identifies a back plane for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.3.1.1.1 |
backPlaneDescriptionA textual string describing a backPlane contained within this system.ro DisplayString .1.3.6.1.4.1.2745.1.2.3.1.1.2 |
backPlanePartNumberA textual string of the part number of this back plane.ro DisplayString .1.3.6.1.4.1.2745.1.2.3.1.1.3 |
backPlaneSerialNumberA textual string of the serial number of this back plane.ro DisplayString .1.3.6.1.4.1.2745.1.2.3.1.1.4 |
backPlaneManufactureDateA textual string of the manufacture date of this back plane.ro DisplayString .1.3.6.1.4.1.2745.1.2.3.1.1.5 |
backPlaneHWRevisionNumberA textual string of the hardware revision date of this back plane.ro DisplayString .1.3.6.1.4.1.2745.1.2.3.1.1.6 |
powerSupplyGroup OBJECT IDENTIFIER .1.3.6.1.4.1.2745.1.2.4 |
powerSupplyTableA table of relevent information pertaining to a backplane contained within this system. SEQUENCE OF PowerSupplyTableEntry .1.3.6.1.4.1.2745.1.2.4.1 |
powerSupplyTableEntryAn entry in the table, containing relevant information about a specific backplane contained within this system. PowerSupplyTableEntry .1.3.6.1.4.1.2745.1.2.4.1.1 |
powerSupplyEntityIndexA unique value, the entPhysicalIndex from the entity MIB, that identifies a power supply for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.4.1.1.1 |
powerSupplyStatusThe on off state of this power supply.ro Enumeration .1.3.6.1.4.1.2745.1.2.4.1.1.2 |
powerSupplyTypeThe type of this power supply.ro Enumeration .1.3.6.1.4.1.2745.1.2.4.1.1.3 |
powerSupply5vCurrentThe actual voltage level of this 5 volt supply as measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.4.1.1.4 |
powerSupply5vMinThe minimum operating voltage level of this 5 volt supply, measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.4.1.1.5 |
powerSupply5vMaxThe maximum operating voltage level of this 5 volt supply, measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.4.1.1.6 |
powerSupplyUnitIdentifierThe identifier of this supply.ro Enumeration .1.3.6.1.4.1.2745.1.2.4.1.1.7 |
modulesGroup OBJECT IDENTIFIER .1.3.6.1.4.1.2745.1.2.5 |
moduleTableA table of common information relevent to modules within this system. SEQUENCE OF ModuleTableEntry .1.3.6.1.4.1.2745.1.2.5.1 |
moduleTableEntryAn entry in the common module information table. ModuleTableEntry .1.3.6.1.4.1.2745.1.2.5.1.1 |
modEntityIndexA unique value, entPhysicalIndex from the entity MIB, that identifies a module for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.1.1.1 |
modAdminStateThe desired state of up or down of this module. If the design of this module does not include the abiltiy to control this module then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then up and down are the valid states that a user can set this object to.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.1.1.2 |
modOperStatusThe current operational (up/down) state of this module.ro Enumeration .1.3.6.1.4.1.2745.1.2.5.1.1.3 |
modTypeThe type of module resident in this system.ro Enumeration .1.3.6.1.4.1.2745.1.2.5.1.1.4 |
modDescriptionA textual description of this type of module.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.1.1.5 |
modNameA user defined name for this module.rw DisplayString .1.3.6.1.4.1.2745.1.2.5.1.1.6 |
modPartNumberA textual string identifying the part number of this module.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.1.1.7 |
modSerialNumberA textual string identifying the serieal number of this module.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.1.1.8 |
modManufactureDateA textual string identifying the date that this module was manufactured.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.1.1.9 |
modDiagnosticTestStatusA textual string indicating the status of the last diagnostic test performed on this module including the date and time.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.1.1.10 |
modHWRevisionNumberA textual string identifying the hardware revision number of this module.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.1.1.11 |
modNumPortsThe number of ports conntained within this module.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.1.1.12 |
modFirstSlotThe first slot which is the leftmost slot that this module physically resides in.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.1.1.13 |
modNumSlotsOccupiedThe total number of slots that this module physically occupies.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.1.1.14 |
modResetThe trigger to reset this module. If the design of this module does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.1.1.15 |
mgmntTableA table of information common to management modules within this system. SEQUENCE OF MgmntTableEntry .1.3.6.1.4.1.2745.1.2.5.2 |
mgmntTableEntryAn entry in the managment module information table. MgmntTableEntry .1.3.6.1.4.1.2745.1.2.5.2.1 |
mgmntEntityIndexA unique value, the entPhysicalIndex from the entity MIB, that identifies a managemnt module for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.1 |
mgmntBootImageNameA textual description of the name of the Boot image.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.2.1.2 |
mgmntBootImageVersionA textual description of the version of the Boot image The vesion will include the time and date of the build.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.2.1.3 |
mgmntCoreImageNameA textual description of the name of the Core image.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.2.1.4 |
mgmntCoreImageVersionA textual description of the version of the Core image The vesion will include the time and date of the build.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.2.1.5 |
mgmntAppImageNameA textual description of the name of the Application (personality) image.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.2.1.6 |
mgmntAppImageVersionA textual description of the version of the Application (personality) image. The vesion will include the time and date of the build.ro DisplayString .1.3.6.1.4.1.2745.1.2.5.2.1.7 |
mgmntRamMemorySizeThe size of RAM memory measured in number of bytes.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.8 |
mgmntFlashMemorySizeThe size of Flash memory measured in number of bytes.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.9 |
mgmntNVRamMemorySizeThe size of Non Volatile Ram memory measured in number of bytes.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.10 |
mgmnt5vCurrentThe actual voltage level of this 3.3 volt input as measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.11 |
mgmnt5vMinThe minimum operating voltage level of this 5 volt input, measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.12 |
mgmnt5vMaxThe maximum operating voltage level of this 5 volt input, measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.13 |
mgmnt3pt3vCurrentThe actual voltage level of this 3.3 volt input as measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.14 |
mgmnt3pt3vMinThe minimum operating voltage level of this 3.3 volt input, measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.15 |
mgmnt3pt3vMaxThe maximum operating voltage level of this 3.3 volt input, measured in millivolts.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.2.1.16 |
mgmntDiagnosticBootErrorThis object indicates the status of the diagnostic boot tests. An error is indicated by turning the error indicator on the management module is on.ro Enumeration .1.3.6.1.4.1.2745.1.2.5.2.1.17 |
singleTwisterTableA table of information common to single twister modules. SEQUENCE OF SingleTwisterTableEntry .1.3.6.1.4.1.2745.1.2.5.3 |
singleTwisterTableEntryAn entry in the single Twister table of information. SingleTwisterTableEntry .1.3.6.1.4.1.2745.1.2.5.3.1 |
stwEntityIndexA unique value, the entPhysicalIndex from the entity MIB, that identifies a single twister module for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.3.1.1 |
stwLinkLossCarryForwardThe ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.3.1.2 |
dualTwisterTableA table of information common to dual twister modules. SEQUENCE OF DualTwisterTableEntry .1.3.6.1.4.1.2745.1.2.5.4 |
dualTwisterTableEntryAn entry in the dual Twister table of information. DualTwisterTableEntry .1.3.6.1.4.1.2745.1.2.5.4.1 |
dtwEntityIndexA unique value, the entPhysicalIndex from the entity MIB, that identifies a dual twister module for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.4.1.1 |
dtwLinkLossCarryForwardThe ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.4.1.2 |
redundantTwisterTableA table of information common to redundant twister modules. SEQUENCE OF RedundantTwisterTableEntry .1.3.6.1.4.1.2745.1.2.5.5 |
redundantTwisterTableEntryAn entry in the table containing redundant twister information. RedundantTwisterTableEntry .1.3.6.1.4.1.2745.1.2.5.5.1 |
rtwEntityIndexA unique value, the entPhysicalIndex from the entity MIB, that identifies a redundant twister module for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.5.5.1.1 |
rtwAutoRestorePrimaryThis object controls the ability to perform auto restoration back to the primary circuit if a secondary switchover had previously occurred. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not selectable.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.2 |
rtwLinkLossCarryForwardThe ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.3 |
rtwActivePortThis object reflects the port that is both receiving and transmitting packets. If the active port is the secondary then the secondary led indicator will be turned on.ro Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.4 |
rtwRedundantTransmissionThe ability of the primary and secondary output ports to transmit the received main input signal simultaneously. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not-applicable.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.5 |
rtwSecondarySwitchOverThis object reflects whether an automatic switch from the primary port to the secondary port has taken place.ro Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.6 |
rtwLinkPulseControlThis object controls the forwarding of the link test pulse to both the primary and secondary ports or the slected port in rtwActivePort. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not-applicable.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.7 |
rtwModeControlThis objects selects the operational mode. Redundant mode provides automatic switchover for port failure redundancy while ABSelect provides a basic A/B port selector.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.8 |
rtwABSelectThis object selects the output port that will send and receive packets. If the design of this module does not include the abiltiy to select the mode, then this object will default to not-selectable and no sets to this object will be allowed.rw Enumeration .1.3.6.1.4.1.2745.1.2.5.5.1.9 |
ePortGroup OBJECT IDENTIFIER .1.3.6.1.4.1.2745.1.2.6 |
ePortTableA table of relevant information about the ports(s) contained within a module. SEQUENCE OF EPortTableEntry .1.3.6.1.4.1.2745.1.2.6.1 |
ePortTableEntryAn entry in the table containing port related information within a module. EPortTableEntry .1.3.6.1.4.1.2745.1.2.6.1.1 |
ePortEntityIndexA unique value, the entPhysicalIndex from the entity MIB, that identifies a port for which this entry contains information.ro Integer32 .1.3.6.1.4.1.2745.1.2.6.1.1.1 |
ePortIfIndexA unique identifier indicating the MIB-II interface number of this port. NOTE: ports on media translators DO NOT conform to MIB-II definition of an interface.ro Integer32 .1.3.6.1.4.1.2745.1.2.6.1.1.2 |
ePortTypeA unique value that identifies the type of port. Included in the port type is the maximum speed at which this port may operate at and the cable type.ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.3 |
ePortDescriptionA textual description of this type of port.ro DisplayString .1.3.6.1.4.1.2745.1.2.6.1.1.4 |
ePortNameThe user defined name of this port.rw DisplayString .1.3.6.1.4.1.2745.1.2.6.1.1.5 |
ePortLinkStatusThe link status of this port. This status indicates the reception of link test pulse signals generated from an attached device. This object is used in the ePortLinkStatusChangeTrap.ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.6 |
ePortAdminStateThe desired state of this port. If the design of this module does not include the abiltiy to control this port then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then enable and disable are the only valid states that a user can set this object to. This object is used in the PortControlTrap.rw Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.7 |
ePortOperStatusThis object indicates the current operational state of this port.ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.8 |
ePortDuplexAdminThis object specifies the desired state of half or full duplex mode for this port. If the design of this module does not include the ability to select duplex, then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit duplex selection then half and full are the valid states that a user can set this object to.rw Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.9 |
ePortDuplexOperThis object indicates the current duplex mode of this port.ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.10 |
ePortSpeedAdminThis object indicates the current speed that this port is operating at. If the design of this module does not include the abiltiy to control the speed of this then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then all but not-applicable are valid states that a user can set this object to.rw Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.11 |
ePortSpeedOperThis object specifies the desired speed that this port is operating at.ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.12 |
ePortAutoNegotiationAdminThis object indicates the current state of auto negotiation for this port. If the design of this module does not include the ability to select auto negotiation, then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit auto negotiation selection then all but not-applicable are valid states that a user can set this object to.rw Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.13 |
ePortAutoNegotiationOperThis object specifices the desired state of auto negotiation selection. If enabled, this port is capable of auto negotiating full/half duplex and port speed selection.ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.14 |
ePortResetThe trigger to reset this port. If the design of this module does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable.rw Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.15 |
ePortActivityThis object indicates data reception and transmision activity on the active port(s).ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.16 |
ePortConnectorThis object indicates the connector type that this port supports.ro Enumeration .1.3.6.1.4.1.2745.1.2.6.1.1.17 |
ePortParentRelPosThis object indicates this ports relative position in the module to which it is member of.ro Integer32 .1.3.6.1.4.1.2745.1.2.6.1.1.18 |
serialPortGroup OBJECT IDENTIFIER .1.3.6.1.4.1.2745.1.2.7 |
serialPortTableA table of relevent information pertaining to each serial port contained within this system. SEQUENCE OF SerialPortTableEntry .1.3.6.1.4.1.2745.1.2.7.1 |
serialPortTableEntryAn entry in the table, containing relevant information about a specific serial port contained within this system. SerialPortTableEntry .1.3.6.1.4.1.2745.1.2.7.1.1 |
serialPortEntityIndexA unique value, the entPhysicalIndex from the entity MIB, which identifies this serial port.ro Integer32 .1.3.6.1.4.1.2745.1.2.7.1.1.1 |
serialPortDescriptionA textual description of this type of port.ro DisplayString .1.3.6.1.4.1.2745.1.2.7.1.1.2 |
serialPortNameThe user defined name of this port.rw DisplayString .1.3.6.1.4.1.2745.1.2.7.1.1.3 |
serialPortSpeedThe speed that this port transmits and receives at.ro Enumeration .1.3.6.1.4.1.2745.1.2.7.1.1.4 |
serialPortDataBitsThe number of bits in a character.ro Enumeration .1.3.6.1.4.1.2745.1.2.7.1.1.5 |
serialPortParityThe port's sense of a character parity bit.ro Enumeration .1.3.6.1.4.1.2745.1.2.7.1.1.6 |
serialPortStopBitsThe number of stop bits for this port.ro Enumeration .1.3.6.1.4.1.2745.1.2.7.1.1.7 |
serialPortFlowControlThe type of flow control for this port.ro Enumeration .1.3.6.1.4.1.2745.1.2.7.1.1.8 |
serialPortConnectorThis object indicates the connector type that this port supports.ro Enumeration .1.3.6.1.4.1.2745.1.2.7.1.1.9 |