IOMEGANAS-MIB
AI MIB Summary
The IOMEGANAS-MIB enables SNMP-based monitoring and management of Iomega Network Attached Storage (NAS) appliances, specifically exposing hardware status indicators, interface statistics, and storage subsystem metrics such as disk health, volume utilization, and system temperature.
MIB for Iomega NAS
Main OID:
lenovoemc.1.3.6.1.4.1.11369
86
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
86 total| Object Name |
|---|
org OBJECT IDENTIFIER .1.3 |
dod OBJECT IDENTIFIER .1.3.6 |
internet OBJECT IDENTIFIER .1.3.6.1 |
private OBJECT IDENTIFIER .1.3.6.1.4 |
enterprises OBJECT IDENTIFIER .1.3.6.1.4.1 |
lenovoemcMIB for Iomega NAS MODULE-IDENTITY .1.3.6.1.4.1.11369 |
iomegaNAS OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10 |
iomegaNASInfo OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.1 |
deviceDescrDescription of this device.ro DisplayString ( SIZE ( 0 .. 255 ) ) .1.3.6.1.4.1.11369.10.1.1 |
deviceNameIomega NAS host name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11369.10.1.2 |
netConfig OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.1.3 |
dns0The first DNS serverro IpAddress .1.3.6.1.4.1.11369.10.1.3.1 |
dns1Backup DNS serverro IpAddress .1.3.6.1.4.1.11369.10.1.3.2 |
wins0The first wins serverro IpAddress .1.3.6.1.4.1.11369.10.1.3.3 |
wins1Backup wins serverro IpAddress .1.3.6.1.4.1.11369.10.1.3.4 |
systemPerformance OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.2 |
ioTableA table of disk I/O performance. SEQUENCE OF IoEntry .1.3.6.1.4.1.11369.10.2.1 |
ioEntryAn entry of one disk I/O performance. IoEntry .1.3.6.1.4.1.11369.10.2.1.1 |
ioIndexioIndex Integer32 .1.3.6.1.4.1.11369.10.2.1.1.1 |
diskNameDisk names such as sda and so onro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.2 |
ioMgrsRead merges per second.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.3 |
ioMgwsWrite merges per second.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.4 |
ioReqrsRead io requests per second.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.5 |
ioReqwsWrite io requests per second.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.6 |
ioKbrsKilobytes read per second.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.7 |
ioKbwsKilobytes written per second.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.8 |
ioAvgQueueAverage queue length.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.9 |
ioAvgWaitAverage waiting time (queue + service)ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.10 |
ioAvgSvcAverage service time at disk.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.11 |
ioAvgUtilAverage disk utilization.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.12 |
ioCpuTimePercentage of CPU time during which I/O requests were issued to the device.ro OCTET STRING .1.3.6.1.4.1.11369.10.2.1.1.13 |
iomegaNASFunctionStatus OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.3 |
bkupTableA table of backup status. SEQUENCE OF BkupEntry .1.3.6.1.4.1.11369.10.3.1 |
bkupEntryAn entry of backup status. BkupEntry .1.3.6.1.4.1.11369.10.3.1.1 |
bkupIndexRecord backup status Integer32 .1.3.6.1.4.1.11369.10.3.1.1.1 |
bkupClientClient Namero OCTET STRING .1.3.6.1.4.1.11369.10.3.1.1.2 |
bkupltStatusLast backup statusro OCTET STRING .1.3.6.1.4.1.11369.10.3.1.1.3 |
bkupTotalSpaceTotal spacero OCTET STRING .1.3.6.1.4.1.11369.10.3.1.1.4 |
remoteAccess OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.3.2 |
raEnabledWhether RA is enabled
0 Disable
1 Enablero Integer32 .1.3.6.1.4.1.11369.10.3.2.1 |
conTableTable for connected client count SEQUENCE OF ConEntry .1.3.6.1.4.1.11369.10.3.3 |
conEntryEntry for connected client count ConEntry .1.3.6.1.4.1.11369.10.3.3.1 |
conIndexIndex for entry Integer32 ( -2147483648 .. 2147483647 ) .1.3.6.1.4.1.11369.10.3.3.1.1 |
conCountConnected client count for a given protocolro Integer32 .1.3.6.1.4.1.11369.10.3.3.1.2 |
conProtocolProtocol used by this kind of clientsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11369.10.3.3.1.3 |
mediaService OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.3.4 |
mediaServiceEnabledWhether media service is enabled
0 disable
1 enablero Integer32 .1.3.6.1.4.1.11369.10.3.4.1 |
iomegaNASStorage OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.4 |
raidStatusDescription of raid status. There are five different status:
NORMAL
REBUILDING
DEGRADED
REBUILDFS
FAULTEDro OCTET STRING .1.3.6.1.4.1.11369.10.4.1 |
raidLevelRaid level(5/10)ro Integer32 ( -2147483648 .. 2147483647 ) .1.3.6.1.4.1.11369.10.4.2 |
diskTableThe table of disks that build the RAID. SEQUENCE OF DiskEntry .1.3.6.1.4.1.11369.10.4.3 |
diskEntryAn entry of one disk. DiskEntry .1.3.6.1.4.1.11369.10.4.3.1 |
diskIndexIndex of disk entry Integer32 ( -2147483648 .. 2147483647 ) .1.3.6.1.4.1.11369.10.4.3.1.1 |
diskIDID of disk in arrayro OCTET STRING .1.3.6.1.4.1.11369.10.4.3.1.2 |
diskSizeCapacity of diskro OCTET STRING .1.3.6.1.4.1.11369.10.4.3.1.3 |
diskStatusStatus of Disk. There are four status:
NORMAL
FOREIGN
FAULTED
MISSINGro OCTET STRING .1.3.6.1.4.1.11369.10.4.3.1.4 |
iomegaNASDevice OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.5 |
usbTableTable of connected usb devices. SEQUENCE OF UsbEntry .1.3.6.1.4.1.11369.10.5.1 |
usbEntryEntry for connected USB device UsbEntry .1.3.6.1.4.1.11369.10.5.1.1 |
usbIndexIndex for entry in the table Integer32 .1.3.6.1.4.1.11369.10.5.1.1.1 |
usbManufactureManufucture of the devicero DisplayString ( SIZE ( 0 .. 255 ) ) .1.3.6.1.4.1.11369.10.5.1.1.2 |
usbModelModel of the USB devicero DisplayString ( SIZE ( 0 .. 255 ) ) .1.3.6.1.4.1.11369.10.5.1.1.3 |
usbTypeUSB device type(such UPS(3), PTP(6), printer(7) and so on)ro Integer32 .1.3.6.1.4.1.11369.10.5.1.1.4 |
iomegaNASSensor OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.6 |
fanTableTable for fan sensors SEQUENCE OF FanEntry .1.3.6.1.4.1.11369.10.6.1 |
fanEntryEntry for fan sensor FanEntry .1.3.6.1.4.1.11369.10.6.1.1 |
fanIndexIndex for the entry Integer32 .1.3.6.1.4.1.11369.10.6.1.1.1 |
fanNameName of the fan sensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11369.10.6.1.1.2 |
fanValueRotation speed of the fan in RPMro Gauge32 .1.3.6.1.4.1.11369.10.6.1.1.3 |
tempTableTable for temperature sensor SEQUENCE OF TempEntry .1.3.6.1.4.1.11369.10.6.2 |
tempEntryEntry for temperature sensor TempEntry .1.3.6.1.4.1.11369.10.6.2.1 |
tempIndexIndex for entry Integer32 .1.3.6.1.4.1.11369.10.6.2.1.1 |
tempNameName of the temperature sensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11369.10.6.2.1.2 |
tempValueThe temperature of the sensor in mC.ro Gauge32 .1.3.6.1.4.1.11369.10.6.2.1.3 |
voltTableTable for volt sensor SEQUENCE OF VoltEntry .1.3.6.1.4.1.11369.10.6.3 |
voltEntryEntry for volt sensor VoltEntry .1.3.6.1.4.1.11369.10.6.3.1 |
voltIndexIndex for the entry Integer32 .1.3.6.1.4.1.11369.10.6.3.1.1 |
voltNameName of the volt sensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11369.10.6.3.1.2 |
voltValueThe voltage in mVro Gauge32 .1.3.6.1.4.1.11369.10.6.3.1.3 |
iomegaNASEvent OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.7 |
eventIDID of the eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11369.10.7.1 |
eventTextDescription of the event.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11369.10.7.2 |
iomegaNASNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.11369.10.8 |
iomegaNASNotificationErrorAn Error EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. NOTIFICATION-TYPE .1.3.6.1.4.1.11369.10.8.1 |
iomegaNASNotificationWarnA Warning EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. NOTIFICATION-TYPE .1.3.6.1.4.1.11369.10.8.2 |
iomegaNASNotificationInfoAn Informational EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. NOTIFICATION-TYPE .1.3.6.1.4.1.11369.10.8.3 |