Home/Catalog/IOMEGANAS-MIB

IOMEGANAS-MIB

AI MIB Summary

The IOMEGANAS-MIB enables SNMP-based monitoring and management of Iomega Network Attached Storage (NAS) appliances, specifically exposing hardware status indicators, interface statistics, and storage subsystem metrics such as disk health, volume utilization, and system temperature.

MIB for Iomega NAS
Main OID:
lenovoemc.1.3.6.1.4.1.11369
86
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

86 total
Object Name
org
OBJECT IDENTIFIER
.1.3
dod
OBJECT IDENTIFIER
.1.3.6
internet
OBJECT IDENTIFIER
.1.3.6.1
private
OBJECT IDENTIFIER
.1.3.6.1.4
enterprises
OBJECT IDENTIFIER
.1.3.6.1.4.1
lenovoemcMIB for Iomega NAS
MODULE-IDENTITY
.1.3.6.1.4.1.11369
iomegaNAS
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10
iomegaNASInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.1
deviceDescrDescription of this device.ro
DisplayString ( SIZE ( 0 .. 255 ) )
.1.3.6.1.4.1.11369.10.1.1
deviceNameIomega NAS host name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11369.10.1.2
netConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.1.3
dns0The first DNS serverro
IpAddress
.1.3.6.1.4.1.11369.10.1.3.1
dns1Backup DNS serverro
IpAddress
.1.3.6.1.4.1.11369.10.1.3.2
wins0The first wins serverro
IpAddress
.1.3.6.1.4.1.11369.10.1.3.3
wins1Backup wins serverro
IpAddress
.1.3.6.1.4.1.11369.10.1.3.4
systemPerformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.2
ioTableA table of disk I/O performance.
SEQUENCE OF IoEntry
.1.3.6.1.4.1.11369.10.2.1
ioEntryAn entry of one disk I/O performance.
IoEntry
.1.3.6.1.4.1.11369.10.2.1.1
ioIndexioIndex
Integer32
.1.3.6.1.4.1.11369.10.2.1.1.1
diskNameDisk names such as sda and so onro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.2
ioMgrsRead merges per second.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.3
ioMgwsWrite merges per second.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.4
ioReqrsRead io requests per second.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.5
ioReqwsWrite io requests per second.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.6
ioKbrsKilobytes read per second.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.7
ioKbwsKilobytes written per second.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.8
ioAvgQueueAverage queue length.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.9
ioAvgWaitAverage waiting time (queue + service)ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.10
ioAvgSvcAverage service time at disk.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.11
ioAvgUtilAverage disk utilization.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.12
ioCpuTimePercentage of CPU time during which I/O requests were issued to the device.ro
OCTET STRING
.1.3.6.1.4.1.11369.10.2.1.1.13
iomegaNASFunctionStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.3
bkupTableA table of backup status.
SEQUENCE OF BkupEntry
.1.3.6.1.4.1.11369.10.3.1
bkupEntryAn entry of backup status.
BkupEntry
.1.3.6.1.4.1.11369.10.3.1.1
bkupIndexRecord backup status
Integer32
.1.3.6.1.4.1.11369.10.3.1.1.1
bkupClientClient Namero
OCTET STRING
.1.3.6.1.4.1.11369.10.3.1.1.2
bkupltStatusLast backup statusro
OCTET STRING
.1.3.6.1.4.1.11369.10.3.1.1.3
bkupTotalSpaceTotal spacero
OCTET STRING
.1.3.6.1.4.1.11369.10.3.1.1.4
remoteAccess
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.3.2
raEnabledWhether RA is enabled 0 Disable 1 Enablero
Integer32
.1.3.6.1.4.1.11369.10.3.2.1
conTableTable for connected client count
SEQUENCE OF ConEntry
.1.3.6.1.4.1.11369.10.3.3
conEntryEntry for connected client count
ConEntry
.1.3.6.1.4.1.11369.10.3.3.1
conIndexIndex for entry
Integer32 ( -2147483648 .. 2147483647 )
.1.3.6.1.4.1.11369.10.3.3.1.1
conCountConnected client count for a given protocolro
Integer32
.1.3.6.1.4.1.11369.10.3.3.1.2
conProtocolProtocol used by this kind of clientsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11369.10.3.3.1.3
mediaService
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.3.4
mediaServiceEnabledWhether media service is enabled 0 disable 1 enablero
Integer32
.1.3.6.1.4.1.11369.10.3.4.1
iomegaNASStorage
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.4
raidStatusDescription of raid status. There are five different status: NORMAL REBUILDING DEGRADED REBUILDFS FAULTEDro
OCTET STRING
.1.3.6.1.4.1.11369.10.4.1
raidLevelRaid level(5/10)ro
Integer32 ( -2147483648 .. 2147483647 )
.1.3.6.1.4.1.11369.10.4.2
diskTableThe table of disks that build the RAID.
SEQUENCE OF DiskEntry
.1.3.6.1.4.1.11369.10.4.3
diskEntryAn entry of one disk.
DiskEntry
.1.3.6.1.4.1.11369.10.4.3.1
diskIndexIndex of disk entry
Integer32 ( -2147483648 .. 2147483647 )
.1.3.6.1.4.1.11369.10.4.3.1.1
diskIDID of disk in arrayro
OCTET STRING
.1.3.6.1.4.1.11369.10.4.3.1.2
diskSizeCapacity of diskro
OCTET STRING
.1.3.6.1.4.1.11369.10.4.3.1.3
diskStatusStatus of Disk. There are four status: NORMAL FOREIGN FAULTED MISSINGro
OCTET STRING
.1.3.6.1.4.1.11369.10.4.3.1.4
iomegaNASDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.5
usbTableTable of connected usb devices.
SEQUENCE OF UsbEntry
.1.3.6.1.4.1.11369.10.5.1
usbEntryEntry for connected USB device
UsbEntry
.1.3.6.1.4.1.11369.10.5.1.1
usbIndexIndex for entry in the table
Integer32
.1.3.6.1.4.1.11369.10.5.1.1.1
usbManufactureManufucture of the devicero
DisplayString ( SIZE ( 0 .. 255 ) )
.1.3.6.1.4.1.11369.10.5.1.1.2
usbModelModel of the USB devicero
DisplayString ( SIZE ( 0 .. 255 ) )
.1.3.6.1.4.1.11369.10.5.1.1.3
usbTypeUSB device type(such UPS(3), PTP(6), printer(7) and so on)ro
Integer32
.1.3.6.1.4.1.11369.10.5.1.1.4
iomegaNASSensor
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.6
fanTableTable for fan sensors
SEQUENCE OF FanEntry
.1.3.6.1.4.1.11369.10.6.1
fanEntryEntry for fan sensor
FanEntry
.1.3.6.1.4.1.11369.10.6.1.1
fanIndexIndex for the entry
Integer32
.1.3.6.1.4.1.11369.10.6.1.1.1
fanNameName of the fan sensorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11369.10.6.1.1.2
fanValueRotation speed of the fan in RPMro
Gauge32
.1.3.6.1.4.1.11369.10.6.1.1.3
tempTableTable for temperature sensor
SEQUENCE OF TempEntry
.1.3.6.1.4.1.11369.10.6.2
tempEntryEntry for temperature sensor
TempEntry
.1.3.6.1.4.1.11369.10.6.2.1
tempIndexIndex for entry
Integer32
.1.3.6.1.4.1.11369.10.6.2.1.1
tempNameName of the temperature sensorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11369.10.6.2.1.2
tempValueThe temperature of the sensor in mC.ro
Gauge32
.1.3.6.1.4.1.11369.10.6.2.1.3
voltTableTable for volt sensor
SEQUENCE OF VoltEntry
.1.3.6.1.4.1.11369.10.6.3
voltEntryEntry for volt sensor
VoltEntry
.1.3.6.1.4.1.11369.10.6.3.1
voltIndexIndex for the entry
Integer32
.1.3.6.1.4.1.11369.10.6.3.1.1
voltNameName of the volt sensorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11369.10.6.3.1.2
voltValueThe voltage in mVro
Gauge32
.1.3.6.1.4.1.11369.10.6.3.1.3
iomegaNASEvent
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.7
eventIDID of the eventro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11369.10.7.1
eventTextDescription of the event.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11369.10.7.2
iomegaNASNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.11369.10.8
iomegaNASNotificationErrorAn Error EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11369.10.8.1
iomegaNASNotificationWarnA Warning EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11369.10.8.2
iomegaNASNotificationInfoAn Informational EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data.
NOTIFICATION-TYPE
.1.3.6.1.4.1.11369.10.8.3