Home/Catalog/IFOTEC-SMI

IFOTEC-SMI

The Structure of Management Information for the IFOTEC enterprise.
Main OID:
ifotec.1.3.6.1.4.1.21362
38
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

38 total
Object Name
ifotecThe Structure of Management Information for the IFOTEC enterprise.
MODULE-IDENTITY
.1.3.6.1.4.1.21362
ifotecGeneralGeneral informations about the IFOTEC product.
OBJECT IDENTIFIER
.1.3.6.1.4.1.21362.101
ifotecSystemIFOTEC System informations.
OBJECT IDENTIFIER
.1.3.6.1.4.1.21362.101.1
ifoSysProductIndexThe ifoSysIndex of the product.ro
Integer32
.1.3.6.1.4.1.21362.101.1.1
ifoSysTablelist of systems present.
SEQUENCE OF IfoSysEntry
.1.3.6.1.4.1.21362.101.1.2
ifoSysEntryAn entry containing system informations.
IfoSysEntry
.1.3.6.1.4.1.21362.101.1.2.1
ifoSysIndexA unique value, greater than zero, for each product.
Integer32
.1.3.6.1.4.1.21362.101.1.2.1.1
ifoSysRefProduct referencero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.2
ifoSysInfoProduct informationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.3
ifoSysFamillyProduct famillyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.4
ifoSysSerialNumberSerial numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.5
ifoSysDateCodeDate codero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.6
ifoSysFirmwareFirmware versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.7
ifoSysBootloaderBootloader versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.8
ifoSysDescrAdministratively-assigned name (sysName)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.9
ifoSysLocationPhysical location (sysLocation)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.10
ifoSysContactPhysical location (sysContact)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.2.1.11
ifoSysUpTimeThe time (in hundredths of a second) since the network management portion of the system was last re-initialized (sysUpTime).ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.21362.101.1.2.1.12
ifoSysMibTablelist of mibs presents in the system.
SEQUENCE OF IfoSysMibEntry
.1.3.6.1.4.1.21362.101.1.3
ifoSysMibEntryAn entry containing mib informations.
IfoSysMibEntry
.1.3.6.1.4.1.21362.101.1.3.1
ifoSysORIfoSysIndexThe index value which uniquely identifies the system in ifoSysMibTable. It is the same value used by ifoSysIndex.
Integer32
.1.3.6.1.4.1.21362.101.1.3.1.1
ifoSysORIndexA unique value, greater than zero, for each mib presents in the system.
Integer32
.1.3.6.1.4.1.21362.101.1.3.1.2
ifoSysORIDAn unique identifier to designate the mib.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.21362.101.1.3.1.3
ifoSysORDescrDescription of the mib.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.1.3.1.4
ifotecTemperaturesIFOTEC Temperature Sensors.
OBJECT IDENTIFIER
.1.3.6.1.4.1.21362.101.2
ifoTemperatureTableA list of sensors.
SEQUENCE OF IfoTemperatureEntry
.1.3.6.1.4.1.21362.101.2.1
ifoTemperatureEntryAn entry containing sensor informations.
IfoTemperatureEntry
.1.3.6.1.4.1.21362.101.2.1.1
ifoTempIfoSysIndexThe index value which uniquely identifies the system in ifoSysMibTable. It is the same value used by ifoSysIndex.
Integer32
.1.3.6.1.4.1.21362.101.2.1.1.1
ifoTempIndexA unique value, greater than zero, for each temperature sensor.
Integer32
.1.3.6.1.4.1.21362.101.2.1.1.2
ifoTempNameThe name of the temperature sensor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.2.1.1.3
ifoTempDescrThe description of the temeprature sensor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21362.101.2.1.1.4
ifoTempValuethe value of the sensor in 0.1 degree Celsius.ro
Integer32
.1.3.6.1.4.1.21362.101.2.1.1.5
ifoTempAlarmStatusIndicates the sensor alarm status.ro
IfotecDataStatus
.1.3.6.1.4.1.21362.101.2.1.1.6
ifoTempLowThldAlarmthe value in 0.1 degree Celsius of the low threshold alarm.ro
Integer32
.1.3.6.1.4.1.21362.101.2.1.1.7
ifoTempHighThldAlarmthe value in 0.1 degree Celsius of the high threshold alarm.ro
Integer32
.1.3.6.1.4.1.21362.101.2.1.1.8
ifoTempLowThldWarningthe value in 0.1 degree Celsius of the low threshold warning.ro
Integer32
.1.3.6.1.4.1.21362.101.2.1.1.9
ifoTempHighThldWarningthe value in 0.1 degree Celsius of the high threshold warning.ro
Integer32
.1.3.6.1.4.1.21362.101.2.1.1.10
ifotecModulesifotecModules provides a root object identifier from which MODULE-IDENTITY values may be assigned.
OBJECT IDENTIFIER
.1.3.6.1.4.1.21362.102