The ETV-AlarmTrap-MIB module defines SNMP trap definitions for Ericsson Television Limited hardware to report critical system fault conditions and alarm states. It enables network management systems to receive asynchronous notifications regarding device failures, service disruptions, or threshold violations specific to Ericsson television infrastructure.
Traps MIB for Ericsson Television Limited devices.
Main OID:
traps.1.3.6.1.4.1.1773.1.1.11
37
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
37 total| Object Name |
|---|
alarm2TrapTableThis table holds the last 20 enterprise specific TRAP messages sent (1 to 6, and 100). This table replace the old trapTable ( general 5 ) SEQUENCE OF Alarm2TrapEntry .1.3.6.1.4.1.1773.1.1.9 |
alarm2TrapEntryAn entry in the alarm2TrapTable. Alarm2TrapEntry .1.3.6.1.4.1.1773.1.1.9.1 |
trapTableIndex2This is the index to the trap table.ro INTEGER .1.3.6.1.4.1.1773.1.1.9.1.1 |
trapSequence2This is the sequence number of the trap.ro Counter32 .1.3.6.1.4.1.1773.1.1.9.1.2 |
referenceNumberT2Code for easy matching of alarms changing state.ro Uint32 .1.3.6.1.4.1.1773.1.1.9.1.3 |
positionNumberT2Identifies the alarm source position.ro Uint32 .1.3.6.1.4.1.1773.1.1.9.1.4 |
portNumberT2This identifies the port on the board sending the trap.ro Uint32 .1.3.6.1.4.1.1773.1.1.9.1.5 |
alarmIdT2Code which indicates an error or event in a module, as defined in the individual modules.ro INTEGER .1.3.6.1.4.1.1773.1.1.9.1.6 |
alarmTypeT2This indicates the type of alarm/event. Input type indicates a alarm/event that could be caused by a faulty input signal Internal alarms are most likely a problem in the reporting device. The reserved value is not to be used.ro Enumeration .1.3.6.1.4.1.1773.1.1.9.1.7 |
alarmTextT2The default alarm text. This will be used to describe the alarm if the receiving application is not configured to override the default text. Understanding the semantics of this field is not required for interpretation of the notificationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1773.1.1.9.1.8 |
sourceTextT2The default source text. This will be used to describe the source causing the alarm if the receiving application is not configured to override the default text. Understanding the semantics of this field is not required for interpretation of the notificationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1773.1.1.9.1.9 |
severityLevelT2From X.733: This parameter defines six severity levels, which provide an indication of how it is perceived that the capability of the managed object has been affected. Those severity levels which represent service affecting conditions ordered from most severe to least severe are Critical, Major, Minor and Warning. The levels defined for use with this current parameter are -cleared: The Cleared severity level indicates the clearing of one or more previously reported alarms. This alarm clears all alarms for this managed object that have the same Alarm type, Probable cause and Specific problems (if given). -indeterminate: The Indeterminate severity level indicates that the severity level cannot be determined. -critical: The Critical severity level indicates that a service affecting condition has occurred and an immediate corrective action is required. Such a severity can be reported, for example, when a managed object becomes totally out of service and its capability must be restored. -major: The Major severity level indicates that a service affecting condition has developed and an urgent corrective action is required. Such a severity can be reported, for example, when there is a severe degradation in the capability of the managed object and its full capability must be restored. minor: The Minor severity level indicates the existence of a non-service affecting fault condition and that corrective action should be taken in order to prevent a more serious (for example, service affecting) fault. Such a severity can be reported, for example, when the detected alarm condition is not currently degrading the capacity of the managed object. -warning: The Warning severity level indicates the detection of a potential or impending service affecting fault, before any significant effects have been felt. Action should be taken to further diagnose (if necessary) and correct the problem in order to prevent it from becoming a more serious service affecting fault.ro Enumeration .1.3.6.1.4.1.1773.1.1.9.1.10 |
moduleTypeT2Identified the source module causing the alarm.ro ModuleType .1.3.6.1.4.1.1773.1.1.9.1.11 |
alarm2CurrentTableThis table holds a list of all currently active alarms in the unit SEQUENCE OF Alarm2CurrentEntry .1.3.6.1.4.1.1773.1.1.10 |
alarm2CurrentEntryAn entry in the currentAlarmTable. Alarm2CurrentEntry .1.3.6.1.4.1.1773.1.1.10.1 |
currentTableIndex2This is the index to the trap table.ro Uint32 .1.3.6.1.4.1.1773.1.1.10.1.1 |
positionNumberC2Identifies the alarm source position.ro Uint32 .1.3.6.1.4.1.1773.1.1.10.1.2 |
portNumberC2This identifies the port of the alarm source.ro Uint32 .1.3.6.1.4.1.1773.1.1.10.1.3 |
alarmIdC2Code which indicates an error or event in a module, as defined in the individual modules.ro Uint32 .1.3.6.1.4.1.1773.1.1.10.1.4 |
alarmTypeC2This indicates the type of alarm/event. Input type indicates a alarm/event that could be caused by a faulty input signal Internal alarms are most likely a problem in the reporting device. The reserved value is not to be used.ro Enumeration .1.3.6.1.4.1.1773.1.1.10.1.5 |
alarmTextC2The default alarm text. This will be used to describe the alarm if the receiving application is not configured to override the default text. Understanding the semantics of this field is not required for interpretation of the notificationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1773.1.1.10.1.6 |
sourceTextC2The default source text. This will be used to describe the source causing the alarm if the receiving application is not configured to override the default text. Understanding the semantics of this field is not required for interpretation of the notificationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1773.1.1.10.1.7 |
severityLevelC2From X.733: This parameter defines six severity levels, which provide an indication of how it is perceived that the capability of the managed object has been affected. Those severity levels which represent service affecting conditions ordered from most severe to least severe are Critical, Major, Minor and Warning. The levels defined for use with this current parameter are -cleared: The Cleared severity level indicates the clearing of one or more previously reported alarms. This alarm clears all alarms for this managed object that have the same Alarm type, Probable cause and Specific problems (if given). -indeterminate: The Indeterminate severity level indicates that the severity level cannot be determined. -critical: The Critical severity level indicates that a service affecting condition has occurred and an immediate corrective action is required. Such a severity can be reported, for example, when a managed object becomes totally out of service and its capability must be restored. -major: The Major severity level indicates that a service affecting condition has developed and an urgent corrective action is required. Such a severity can be reported, for example, when there is a severe degradation in the capability of the managed object and its full capability must be restored. minor: The Minor severity level indicates the existence of a non-service affecting fault condition and that corrective action should be taken in order to prevent a more serious (for example, service affecting) fault. Such a severity can be reported, for example, when the detected alarm condition is not currently degrading the capacity of the managed object. -warning: The Warning severity level indicates the detection of a potential or impending service affecting fault, before any significant effects have been felt. Action should be taken to further diagnose (if necessary) and correct the problem in order to prevent it from becoming a more serious service affecting fault.ro Enumeration .1.3.6.1.4.1.1773.1.1.10.1.8 |
referenceNumberC2Code for easy matching of alarms changing state.ro Uint32 .1.3.6.1.4.1.1773.1.1.10.1.9 |
moduleTypeC2Identified the source module causing the alarm.ro ModuleType .1.3.6.1.4.1.1773.1.1.10.1.10 |
trapsTraps MIB for Ericsson Television Limited devices. MODULE-IDENTITY .1.3.6.1.4.1.1773.1.1.11 |
alarmNormalThis TRAP is sent when an alarm is cleared (severity level 1 according to X.733). May be sent as V1 specific:1 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.1 |
alarmIndeterminateThis TRAP is sent when an alarm with unknown level occur (severity level 2 according to X.733). May be sent as V1 specific:2 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.2 |
alarmWarningThis TRAP is sent when an warning alarm occur (severity level 3 according to X.733). May be sent as V1 specific:3 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.3 |
alarmMinorThis TRAP is sent when an minor alarm occur (severity level 4 according to X.733). May be sent as V1 specific:4 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.4 |
alarmMajorThis TRAP is sent when an major alarm occur (severity level 5 according to X.733). May be sent as V1 specific:5 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.5 |
alarmCriticalThis TRAP is sent when an critical alarm occur (severity level 6 according to X.733). May be sent as V1 specific:6 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.6 |
informationThis TRAP is sent when a devices wishes to send information about an event to the client. These are severity level 100, and are not raised / cleared as with alarm traps. May be sent as V1 specific:100 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.100 |
eventNotifyThis event Trap is sent to notify config changes. May be sent as V1 specific:1 NOTIFICATION-TYPE .1.3.6.1.4.1.1773.1.1.11.101 |
eventTraps OBJECT IDENTIFIER .1.3.6.1.4.1.1773.1.1.15 |
currentEventIndexThis is the index for the last event-trap sent. In essence this is incremented every time the device status changes.ro Uint32 .1.3.6.1.4.1.1773.1.1.15.1 |
currentEventTextA description of the event.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1773.1.1.15.2 |