ESI-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for ESI-MIB.
300
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
300 total| Object Name |
|---|
esi OBJECT IDENTIFIER .1.3.6.1.4.1.683 |
general OBJECT IDENTIFIER .1.3.6.1.4.1.683.1 |
genGroupVersionThe version for the general group.ro INTEGER .1.3.6.1.4.1.683.1.1 |
genMIBVersionThe version of the MIB.ro INTEGER .1.3.6.1.4.1.683.1.2 |
genProductNameA textual description of the device.ro DisplayString .1.3.6.1.4.1.683.1.3 |
genProductNumberThe product number of the device.ro DisplayString .1.3.6.1.4.1.683.1.4 |
genSerialNumberThe serial number of the device.ro DisplayString .1.3.6.1.4.1.683.1.5 |
genHWAddressThe device's hardware address.ro OCTET STRING .1.3.6.1.4.1.683.1.6 |
genCableTypeIndicates the network cable type connected to the
device.ro Enumeration .1.3.6.1.4.1.683.1.7 |
genDateCodeThe device's datecode.ro DisplayString .1.3.6.1.4.1.683.1.8 |
genVersionA string indicating the version of the firmware.ro DisplayString .1.3.6.1.4.1.683.1.9 |
genConfigurationDirtyA variable's value has been changed which will
require that the device be reset or power cycled
before it will take effect.
Set cmdReset to take this action.
A list of critical variables that will cause
genConfigurationDirty to be set follows:
snmpGetCommunityName,
snmpSetCommunityName,
trPriority,
trEarlyTokenRelease,
trPacketSize,
trRouting,
trLocallyAdminAddr,
psJetAdminEnabled,
outputType,
outputHandshake,
tcpipEnabled,
tcpipIPAddress,
tcpipDefaultGateway,
tcpipSubnetMask,
tcpipUsingNetProtocols,
tcpipBootProtocolsEnabled,
tcpipRawPortNumber,
tcpipMLPTCPPort,
tcpipMLPPort,
nwEnabled,
nwSetFrameFormat,
nwMode,
nwPrintServerName,
nwPrintServerPassword,
nwQueueScanTime,
nwFileServerName,
nwPortPrinterNumber,
nwPortFontDownload,
nwPortPCLQueue,
nwPortPSQueue,
nwPortFormsOn,
nwPortNotification,
bvEnabled,
bvSetSequencedRouting,
bvLoginName,
bvLoginPassword,
bvPrintServiceName,
bvPrintServiceRouting,
lmEnabled,
eTalkEnabledro Enumeration .1.3.6.1.4.1.683.1.10 |
genCompanyNameA string indicating the manufacturer of the device.ro DisplayString .1.3.6.1.4.1.683.1.11 |
genCompanyLocA string indicating the location of the manufacturer
of the device.ro DisplayString .1.3.6.1.4.1.683.1.12 |
genCompanyPhoneA string indicating the phone number of the
manufacturer of the device.ro DisplayString .1.3.6.1.4.1.683.1.13 |
genCompanyTechSupportA string indicating the technical support information
for the device.ro DisplayString .1.3.6.1.4.1.683.1.14 |
genProtocols OBJECT IDENTIFIER .1.3.6.1.4.1.683.1.15 |
genNumProtocolsThe number of network protocols supported on the
device.ro INTEGER .1.3.6.1.4.1.683.1.15.1 |
genProtocolTableA list of network protocols. The number of
entries is given by the value of genNumProtocols. SEQUENCE OF GenProtocolEntry .1.3.6.1.4.1.683.1.15.2 |
genProtocolEntryA network protocol supported on the device. GenProtocolEntry .1.3.6.1.4.1.683.1.15.2.1 |
genProtocolIndexA unique value for each network protocol. Its
value ranges between 1 and the value of
genNumProtocols. The value for each protocol must
remain constant at least from one re-initialization
of the entity's network management system to the next
re-initialization.ro INTEGER .1.3.6.1.4.1.683.1.15.2.1.1 |
genProtocolDescrA textual string describing the network protocol.ro DisplayString .1.3.6.1.4.1.683.1.15.2.1.2 |
genProtocolIDA unique identification number for the network
protocol.ro Enumeration .1.3.6.1.4.1.683.1.15.2.1.3 |
genSysUpTimeStringA string indicating the system up time for the device.ro DisplayString .1.3.6.1.4.1.683.1.16 |
commands OBJECT IDENTIFIER .1.3.6.1.4.1.683.2 |
cmdGroupVersionThe version for the commands group.ro INTEGER .1.3.6.1.4.1.683.2.1 |
cmdResetA value of 2 will reset the device. The following
list of variables will also cause the device to reset
itself.
cmdRestoreDefaults,
snmpRestoreDefaults,
trRestoreDefaults,
outputRestoreDefaults,
tcpipRestoreDefaults,
tcpipFirmwareUpgrade,
nwRestoreDefaults,
nwFirmwareUpgrade,
bvRestoreDefaults,
bvFirmwareUpgrade,
eTalkRestoreDefaultsrw Enumeration .1.3.6.1.4.1.683.2.2 |
cmdPrintConfigA value of 2 will cause the device to print a
configuration page.rw Enumeration .1.3.6.1.4.1.683.2.3 |
cmdRestoreDefaultsA value of 2 will restore all parameters on the device
to factory defaults, as well as reset the device.rw Enumeration .1.3.6.1.4.1.683.2.4 |
esiSNMP OBJECT IDENTIFIER .1.3.6.1.4.1.683.3 |
snmpGroupVersionThe version for the snmp group.ro INTEGER .1.3.6.1.4.1.683.3.1 |
esiSNMPCommands OBJECT IDENTIFIER .1.3.6.1.4.1.683.3.2 |
snmpRestoreDefaultsA value of 2 will restore all SNMP parameters
on the device to factory defaults, as well as reset
the device.rw Enumeration .1.3.6.1.4.1.683.3.2.1 |
snmpGetCommunityNameGet community name for the managed node.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.3.3 |
snmpSetCommunityNameSet community name for the managed node. This value
cannot be read, just set.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.3.4 |
snmpTrapCommunityNameTrap community name for the managed node.rw DisplayString .1.3.6.1.4.1.683.3.5 |
driver OBJECT IDENTIFIER .1.3.6.1.4.1.683.4 |
driverGroupVersionThe version for the driver group.ro INTEGER .1.3.6.1.4.1.683.4.1 |
driverRXPacketsThe number of packets received.ro Counter .1.3.6.1.4.1.683.4.2 |
driverTXPacketsThe number of packets transmitted.ro Counter .1.3.6.1.4.1.683.4.3 |
driverRXPacketsUnavailableThe number of inbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being deliverable to a
higher-layer protocol due to a lack of buffer space.ro Counter .1.3.6.1.4.1.683.4.4 |
driverRXPacketErrorsThe number of inbound packets that contained
errors preventing them from being deliverable to a
higher-layer protocol.ro Counter .1.3.6.1.4.1.683.4.5 |
driverTXPacketErrorsThe number of outbound packets that could not be
transmitted because of errors.ro Counter .1.3.6.1.4.1.683.4.6 |
driverTXPacketRetriesThe number of retransmitted packets.ro Counter .1.3.6.1.4.1.683.4.7 |
driverChecksumErrorsThe number of packets containing checksum errors
received.ro Counter .1.3.6.1.4.1.683.4.8 |
tokenRing OBJECT IDENTIFIER .1.3.6.1.4.1.683.5 |
trGroupVersionThe version for the tokenRing group.ro INTEGER .1.3.6.1.4.1.683.5.1 |
trCommands OBJECT IDENTIFIER .1.3.6.1.4.1.683.5.2 |
trRestoreDefaultsA value of 2 will restore all token-ring parameters
on the device to factory defaults, as well as reset
the device.rw Enumeration .1.3.6.1.4.1.683.5.2.1 |
trConfigure OBJECT IDENTIFIER .1.3.6.1.4.1.683.5.3 |
trPriorityThe token which is passed around the ring until a
station needs it can be assigned a priority from 0 to
6. Priority 0 is the lowest and 6 is the highest. The
priority of the device can be increased to improve
performance. However, the performance of file servers
and crucial stations could be affected.
In order for changes to this variable to take effect,
the device must be reset. See cmdReset to do this.rw INTEGER .1.3.6.1.4.1.683.5.3.1 |
trEarlyTokenReleaseEarly token release allows the device to release the
token immediately after transmitting data but only on
16 Mbps systems. This feature enhances ring performance.
In order for changes to this variable to take effect,
the device must be reset. See cmdReset to do this.rw Enumeration .1.3.6.1.4.1.683.5.3.2 |
trPacketSizeYou should only change the packet size if you are
using a driver for your Token Ring adapter which
allows packet sizes greater than One_K.
In order for changes to this variable to take effect,
the device must be reset. See cmdReset to do this.rw Enumeration .1.3.6.1.4.1.683.5.3.3 |
trRoutingSet this variable to change the source routing
configuration on the device.
Off: No source routing.
All, None: All-routes broadcast, nonbroadcast return.
The frame will be transmitted on every route within
the network resulting in multiple copies on a given ring.
Single, All: Single-route broadcast, all routes
broadcast return. The frame will be transmitted across
the designated bridges, which will result in the frame
appearing only once on each ring. The response frame
is on all routes broadcast to the originator.
Single, None: Single-route broadcast, nonbroadcast
return. The frame will be transmitted across designated
bridges, which will result in the frame appearing only
once each ring.
In order for changes to this variable to take effect,
the device must be reset. See cmdReset to do this.rw Enumeration .1.3.6.1.4.1.683.5.3.4 |
trLocallyAdminAddrThis is the locally administered node address for the
device. Valid values are 000000000000 and between
400000000000 and 7FFFFFFFFFFF. A value of 000000000000
indicates that a locally administered address is not in
use.rw OCTET STRING .1.3.6.1.4.1.683.5.3.5 |
printServers OBJECT IDENTIFIER .1.3.6.1.4.1.683.6 |
trapPrinterOnlineThe printer is on-line. This trap will be sent
out after a printer error condition has been cleared. TRAP-TYPE .1.3.6.1.4.1.683.6.0.1 |
trapPrinterOfflineThe printer is off-line. TRAP-TYPE .1.3.6.1.4.1.683.6.0.2 |
trapNoPrinterAttachedNo printer is attached to the output port. TRAP-TYPE .1.3.6.1.4.1.683.6.0.3 |
trapPrinterTonerLowThe printer toner is low. TRAP-TYPE .1.3.6.1.4.1.683.6.0.4 |
trapPrinterPaperOutThe printer is out of paper. TRAP-TYPE .1.3.6.1.4.1.683.6.0.5 |
trapPrinterPaperJamThe printer has a paper jam. TRAP-TYPE .1.3.6.1.4.1.683.6.0.6 |
trapPrinterDoorOpenThe printer door is open. TRAP-TYPE .1.3.6.1.4.1.683.6.0.7 |
trapPrinterErrorGeneral printer error. TRAP-TYPE .1.3.6.1.4.1.683.6.0.16 |
psGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.1 |
psGroupVersionThe version for the psGeneral group.ro INTEGER .1.3.6.1.4.1.683.6.1.1 |
psJetAdminEnabledIndicates whether or not the JetAdmin support is
enabled on the print server.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.1.2 |
psVerifyConfigurationThis variable is used to force the print server to verify valid configuration
settings. Setting the variable to the appropriate enumeration will cause the
print server to verify the settings for that enumeration. If the settings are
valid, the result of the set will be OK. If the settings are not valid, the
result will be BadValue. Gets on this variable will always return 0.
1 - Indicates whether or not the current serial configuration is
valid.
Valid configurations - If the serial port is set in bidirectional mode,
the baud rate must be less than 115200 and the handshaking must be set to
hardware handshaking.
2 - Not used yet.rw Enumeration .1.3.6.1.4.1.683.6.1.3 |
psOutput OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.2 |
outputGroupVersionThe version for the output group.ro INTEGER .1.3.6.1.4.1.683.6.2.1 |
outputCommands OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.2.2 |
outputRestoreDefaultsA value of 2 will restore all output parameters on
the print server to factory defaults, as well as reset
the print server.rw Enumeration .1.3.6.1.4.1.683.6.2.2.1 |
outputCommandsTableA list of physical output ports. The number of
entries is given by the value of outputNumPorts. SEQUENCE OF OutputCommandsEntry .1.3.6.1.4.1.683.6.2.2.2 |
outputCommandsEntryA physical output port on the print server. OutputCommandsEntry .1.3.6.1.4.1.683.6.2.2.2.1 |
outputCancelCurrentJobA value of 2 will cancel the job currently printing
on that port.rw Enumeration .1.3.6.1.4.1.683.6.2.2.2.1.1 |
outputConfigure OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.2.3 |
outputNumPortsThe number of physical output ports on the print
server.ro INTEGER .1.3.6.1.4.1.683.6.2.3.1 |
outputTableA list of physical output ports. The number of
entries is given by the value of outputNumPorts. SEQUENCE OF OutputEntry .1.3.6.1.4.1.683.6.2.3.2 |
outputEntryA physical output port on the print server. OutputEntry .1.3.6.1.4.1.683.6.2.3.2.1 |
outputIndexA unique value for each physical output port.
Its value ranges between 1 and the value of
outputNumPorts. The value for each protocol must
remain constant at least from one re-initialization
of the entity's network management system to the next
re-initialization.ro INTEGER .1.3.6.1.4.1.683.6.2.3.2.1.1 |
outputNameA textual description of the output port.rw DisplayString .1.3.6.1.4.1.683.6.2.3.2.1.2 |
outputStatusStringA string indicating the status of the physical
output port.ro DisplayString .1.3.6.1.4.1.683.6.2.3.2.1.3 |
outputStatusIndicates status of the printer. Get
outputExtendedStatus for further information.ro Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.4 |
outputExtendedStatusIndicates printer status to be used in conjunction with
outputStatus.ro Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.5 |
outputPrinterThe type of printer the output port is attached to.
Even if the group is supported, this variable may not
be supported.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.6 |
outputLanguageSwitchingIndicates the language switching option for the physical
port.
Even if the group is supported, this variable may not be
supported.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.7 |
outputConfigLanguageIndicates the language that configuration pages will be
printed in.
If set to off, a config sheet will not be printed on this
port.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.8 |
outputPCLStringThis string will be sent out the physical port if
(1) outputLanguageSwitching is set to PCL or
outputLanguageSwitching is set to Auto and the job is
determined to be PCL, and (2) outputPrinter is set to
No_Specific_Printer.
Even if the group is supported, this variable may not be
supported.rw OCTET STRING .1.3.6.1.4.1.683.6.2.3.2.1.9 |
outputPSStringThis string will be sent out the physical port if
(1) outputLanguageSwitching is set to PostScript or
outputLanguageSwitching is set to Auto and the job is
determined to be PostScript, and (2) outputPrinter is
set to No_Specific_Printer.
Even if the group is supported, this variable may not be
supported.rw OCTET STRING .1.3.6.1.4.1.683.6.2.3.2.1.10 |
outputCascadedA value of 2 indicates that the physical output port is
connected to an Extended System's printer sharing device.
Even if the group is supported, this variable may not be
supported.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.11 |
outputSettingIndicates the type (and optionally speed) for the
physical output port. Setting this variable to physical
connections (such as Parallel) will result in an error.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.12 |
outputOwnerIndicates which protocol or task currently is printing on
the port.ro Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.13 |
outputBIDIStatusEnabledA value of 2 indicates that the BIDI status system is
enabled.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.14 |
outputPrinterModelA string indicating the printer model attached to the output port.ro DisplayString .1.3.6.1.4.1.683.6.2.3.2.1.15 |
outputPrinterDisplayA string indicating the message on the attached printer front panel.ro DisplayString .1.3.6.1.4.1.683.6.2.3.2.1.16 |
outputCapabilitiesThis field is implemented as a BIT mask. If the bit is set then
the port is capable of functioning in this mode.
Bit Property
0 Serial Unidirectional Baud 9600
1 Serial Unidirectional Baud 19200
2 Serial Unidirectional Baud 38400
3 Serial Unidirectional Baud 57600
4 Serial Unidirectional Baud 115200
5 Serial Bidirectional Baud 9600
6 Serial Bidirectional Baud 19200
7 Serial Bidirectional Baud 38400
8 Serial Bidirectional Baud 57600
19 Infrared Input on serial port
20 Serial Input
21 Serial Configuration Settings
22 Parallel Compatibility Mode (no bidi)
23 IEEE 1284 Standard Nibble Mode
24 ZLink
25 Bidirectional Support (PJL status)
26 Serial Software Handshaking
27 Serial Output
28 Extended Link Technology
29 Printer Internal (MIO)
30 IEEE 1284 ECP or Fast Nibble Modero Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.17 |
outputHandshakeIf the port in serial mode operation this indicates the
handshaking method being used. Setting this value to 'not-
supported' will result in an error. Setting this value on
non serial capable ports will result in an error.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.18 |
outputDataBitsIf the port in serial mode operation this indicates the
number of data bits being used. Setting this value to 'not-
supported' will result in an error. Setting this value on
non serial capable ports will result in an error.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.19 |
outputStopBitsIf the port in serial mode operation this indicates the
number of stop bits being used. Setting this value to 'not-
supported' will result in an error. Setting this value on
non serial capable ports will result in an error.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.20 |
outputParityIf the port in serial mode operation this indicates the
parity checking method being used. Setting this value to 'not-
supported' will result in an error. Setting this value on
non serial capable ports will result in an error.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.21 |
outputBaudRateIf the port in serial mode operation this indicates the
baud rate being used. Setting this value on
non serial capable ports will result in an error.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.22 |
outputProtocolManagerIndicates the type of output protocol manager being used on the
port. Protocol-none means either there is no printer attached or
the print server has not yet determined which output managers are
supported on the printer. Protocol-compatibility means the printer
does not support any of the protocol managers supported by the print
server. Protocol-1284-4 means the output is using the 1284.4 logical
port protocol manager.ro Enumeration .1.3.6.1.4.1.683.6.2.3.2.1.23 |
outputDisplayMaskBit mask describing what should be displayed by the utilities
bit Description
-
0 outputCancelCurrentJob (Includes all CancelCurrentJob info)
1 outputName
2 outputStatusString
3 outputStatus
4 outputExtendedStatus
5 outputPrinter
6 outputLanguageSwitching
7 outputConfigLanguage
8 outputString (Includes outputPCLString and outputPSString)
9 outputCascaded
10 outputSetting
11 outputOwner
12 outputBIDIStatusEnabled
13 outputPrinterModel
14 outputPrinterDisplay
15 outputHandshake
16 outputJobLog (includes all job logging)
17 outputSerialConfigro INTEGER .1.3.6.1.4.1.683.6.2.4 |
outputAvailableTrapsMaskBit mask describing what output printer traps are available
bit Description
-
0 online
1 offline
2 printer attached
3 toner low
4 paper out
5 paper jam
6 door open
7 printer errorro INTEGER .1.3.6.1.4.1.683.6.2.5 |
outputJobLog OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.2.6 |
outputNumLogEntriesThe number of job log entries per output port.ro INTEGER .1.3.6.1.4.1.683.6.2.6.1 |
outputJobLogTableA 2 dimensional list of Job log entries indexed by the output port
number and the log entry index (1 through outputNumJobLogEntries).
The number of entries per output port is given by the value of
outputNumJobLogEntries. SEQUENCE OF OutputJobLogEntry .1.3.6.1.4.1.683.6.2.6.2 |
outputJobLogEntryA Job log entry. OutputJobLogEntry .1.3.6.1.4.1.683.6.2.6.2.1 |
outputJobLogInformationA textual description of print job information.
The protocol, source, and file size are always included.
Other information such as File Server, Queue, File Name, etc
will be included if available.ro DisplayString .1.3.6.1.4.1.683.6.2.6.2.1.1 |
outputJobLogTimeA string indicating the elasped time since the last job was
printed. Reported in form X hours X minutes X seconds.ro DisplayString .1.3.6.1.4.1.683.6.2.6.2.1.2 |
outputTotalJobTableTable showing the total number of jobs printed for each port. SEQUENCE OF OutputTotalJobEntry .1.3.6.1.4.1.683.6.2.6.3 |
outputTotalJobEntryAn entry in the outputTotalJobTable. OutputTotalJobEntry .1.3.6.1.4.1.683.6.2.6.3.1 |
outputTotalJobIndexA unique value for entry in the outputTotalJobTable.
Its value ranges between 1 and the value of
numPorts.ro INTEGER .1.3.6.1.4.1.683.6.2.6.3.1.1 |
outputTotalJobsLoggedThe total number of jobs printed by the port since the
print server was powered on.ro INTEGER .1.3.6.1.4.1.683.6.2.6.3.1.2 |
psProtocols OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3 |
tcpip OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.1 |
tcpipGroupVersionThe version for the tcpip group.ro INTEGER .1.3.6.1.4.1.683.6.3.1.1 |
tcpipEnabledIndicates whether or not the tcpip protocol stack is
enabled on the print server.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.1.2 |
tcpipCommands OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.1.3 |
tcpipRestoreDefaultsA value of 2 will restore all tcpip parameters on
the print server to factory defaults, as well as reset
the print server.rw Enumeration .1.3.6.1.4.1.683.6.3.1.3.1 |
tcpipFirmwareUpgradeA value of 2 will put the print server into firmware
upgrade mode waiting to receive a firmware upgrade file
via tftp.rw Enumeration .1.3.6.1.4.1.683.6.3.1.3.2 |
tcpipConfigure OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.1.4 |
tcpipIPAddressThe Internet Address.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.1 |
tcpipDefaultGatewayThe default gateway for the print server.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.2 |
tcpipSubnetMaskThe subnet mask for the print server.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.3 |
tcpipUsingNetProtocolsA value of 2 indicates that the print server is using
a combination of RARP, BOOTP, default IP address, or
gleaning to determine its IP address.
See tcpipBootProtocolsEnabled to determine which boot
protocols are enabled. If the value of
tcpipUsingNetProtocols is 1, the IP address is stored
permanently in flash memory.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.1.4.4 |
tcpipBootProtocolsEnabledThis is the 16 bit mask which determines which boot
protocols will be used to determine the print server's
IP address.
BIT Boot Protocol Enabled
0 RARP
1 BootP
2 DHCP
3 Gleaning
4 Default Address Enabled (If no address after 2 minutes
timeout and go to 198.102.102.254)
A value of 31 indicates that all boot protocols are
enabled. These protocols will only be used if
tcpipUsingNetProtocols is set to 2.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.5 |
tcpipIPAddressSourceThis variable indicates how the IP address for the
print server was determined.ro Enumeration .1.3.6.1.4.1.683.6.3.1.4.6 |
tcpipIPAddressServerAddressThis variable indicates the source of the IP address
if a boot protocol was used. This value will be
0.0.0.0 if no boot server was used.ro IpAddress .1.3.6.1.4.1.683.6.3.1.4.7 |
tcpipTimeoutCheckingA value of 2 indicates that a packet timeout
will be active on all tcp connections. If a packet has
not been received from the connection within this timeout the
connection will be reset.
To set this timeout, see tcpipTimeoutCheckingValuerw Enumeration .1.3.6.1.4.1.683.6.3.1.4.8 |
tcpipNumTrapsThe number of UDP trap destinations.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.9 |
tcpipTrapTableA list of UDP trap definitions. The number of
entries is given by the value of tcpipNumTraps. SEQUENCE OF TcpipTrapEntry .1.3.6.1.4.1.683.6.3.1.4.10 |
tcpipTrapEntryAn entry in the tcpipTrapTable. TcpipTrapEntry .1.3.6.1.4.1.683.6.3.1.4.10.1 |
tcpipTrapIndexA unique value for entry in the tcpipTrapTable.
Its value ranges between 1 and the value of
tcpipNumTraps.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.10.1.1 |
tcpipTrapDestinationThis is the IP address that traps are sent to.
A value of 0.0.0.0 will disable traps over UDP.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.10.1.2 |
tcpipProtocolTrapMaskThis is the 16 bit mask which determines which protocol
specific traps will be sent out via UDP.
Currently no protocol specific traps are supported.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.10.1.3 |
tcpipPrinterTrapMaskThis is the 16 bit mask which determines which printer
specific traps will be sent out via UDP.
A value of 65535 indicates that all printer specific
traps should be reported via UDP.
BIT CONDITION
0 On-line (Condition cleared)
1 Off-line
2 No printer attached
3 Toner Low
4 Paper Out
5 Paper Jam
6 Door Open
15 Printer Errorrw INTEGER .1.3.6.1.4.1.683.6.3.1.4.10.1.4 |
tcpipOutputTrapMaskThis is the 16 bit mask which determines which physical
output ports will be checked when generating printer
specific traps to be sent out via UDP.
A value of 65535 indicates that all physical output ports
will generate traps.
BIT CONDITION
0 Port 1
1 Port 2
2 Port 3
3 Port 4
... ...rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.10.1.5 |
tcpipBannersA value of 2 indicates that banners will be printed
with tcpip jobs.
Even if the group is supported, this variable may not be
supported.rw Enumeration .1.3.6.1.4.1.683.6.3.1.4.11 |
tcpipWinsAddressThe IP address of the WINS server.
The print server will register its sysName to
this WINS server.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.12 |
tcpipWinsAddressSourceThe source of the WINS server address.
If set to dhcp, the print server will use the
WINS address supplied with dhcp.
If it is set to permanent, it will use the
WINS address stored in flash.rw Enumeration .1.3.6.1.4.1.683.6.3.1.4.13 |
tcpipConfigPasswordThe print server html/telnet configuration password.
This value cannot be read, just set.rw DisplayString .1.3.6.1.4.1.683.6.3.1.4.14 |
tcpipTimeoutCheckingValueThe TCP connection timeout in seconds.
A value of 0 has the same effect as disabling
timeout checking.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.15 |
tcpipArpIntervalThe ARP interval in minutes.
The print server will ARP itself once when
this timer expires. Set to 0 to disable.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.16 |
tcpipRawPortNumberThe raw TCP port number the print server will listen
for print jobs on. On multiple port devices, additional
ports will sequentially follow this port number.
The default port is 9100. Setting this value to a TCP
port that is in use by another TCP application will
return an error.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.17 |
tcpipNumSecurityThe number of secure IP address ranges.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.18 |
tcpipSecurityTableA list of secure IP address ranges. This adds security for both
printing and admin rights.
AdminEnabled: When the admin enabled field is set to yes for a secure
address range, the print server may only be configured via IP from
IP address within that range. If the admin field is not set for any address
ranges, the print server will accept admin commands from any IP address
which has the valid community names and/or passwords.
PortMask: When there is a port mask set for a secure IP address range, the
print server will only accept TCP/IP print jobs from hosts that are in the
secure address range. If there are no ranges with a port mask set, the print
server will accept TCP/IP print jobs from any host.
The number of entries is given by the value of tcpipNumSecurity. SEQUENCE OF TcpipSecurityEntry .1.3.6.1.4.1.683.6.3.1.4.19 |
tcpipSecurityEntryAn entry in the tcpipSecurityTable. TcpipSecurityEntry .1.3.6.1.4.1.683.6.3.1.4.19.1 |
tcpipSecurityIndexA unique value for entry in the tcpipSecurityTable.
Its value ranges between 1 and the value of
tcpipNumSecurity.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.19.1.1 |
tcpipSecureStartIPAddressThis is the starting IP address for the secure IP
address range. A value of 0.0.0.0 for both
tcpipStartIPAddress and tcpipEndIPAddress will
disable the address range.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.19.1.2 |
tcpipSecureEndIPAddressThis is the ending IP address for the secure IP
address range. A value of 0.0.0.0 for both
tcpipStartIPAddress and tcpipEndIPAddress will
disable the address range.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.19.1.3 |
tcpipSecurePrinterMaskThis is the 8 bit mask which determines which physical
output ports this range of IP addresses can print to.
A value of 127 indicates that the range of IP addresses
can print to any of the output ports.
This value can not be configured until a valid start and
end address range have been configured.
BIT CONDITION
0 Port 1
1 Port 2
2 Port 3
3 Port 4
... ...
8 Reserved, must be set to 0.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.19.1.4 |
tcpipSecureAdminEnabledThis allows an advanced level of admin security for IP. Setting this will
restrict which IP addresses can configure the print server. The
correct community names and passwords are still required if this is used, it
just adds another level of security.
Indicates whether or not admin rights are enabled for this range of
IP addresses. If no range of addresses has this enabled, then any IP address
can configure the print server if it has the correct community names and/or
passwords. If this field is set to yes for any range of addresses, the
print server will only be configurable via IP from that range of addresses.
This value can not be configured until a valid start and end address range
have been configured.rw Enumeration .1.3.6.1.4.1.683.6.3.1.4.19.1.5 |
tcpipLowBandwidthA value of 2 will optimize the TCP stack for low bandwidth
networks. A value of 1 will optimize the TCP stack for high
bandwidth networks.rw Enumeration .1.3.6.1.4.1.683.6.3.1.4.20 |
tcpipNumLogicalPrintersThe number of available logical printers.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.21 |
tcpipMLPTableA table of the available logical printers.
The number of entries is given by the value of tcpipNumLogicalPrinters. SEQUENCE OF TcpipMLPEntry .1.3.6.1.4.1.683.6.3.1.4.22 |
tcpipMLPEntryAn entry in the tcpipMLPTable. TcpipMLPEntry .1.3.6.1.4.1.683.6.3.1.4.22.1 |
tcpipMLPIndexA unique value for entry in the tcpipMLPTable.
Its value ranges between 1 and the value of
tcpipNumLogicalPrinters.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.22.1.1 |
tcpipMLPNameContains the name of the logical printer. This name is also
the LPR remote queue name associated with the logical printer.rw DisplayString .1.3.6.1.4.1.683.6.3.1.4.22.1.2 |
tcpipMLPPortThe number of the physical output port associated with the logical
printer.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.22.1.3 |
tcpipMLPTCPPortThe TCP port associated with the logical printer. Any print data
sent to this TCP port will be processed through this logical
printer entry.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.22.1.4 |
tcpipMLPPreStringThis contains any data that should be sent down to the printer
at the beginning of jobs sent to this logical printer. To enter
non-printable ascii characters in the string, enclose the decimal
value inside of <>. For example, to enter an ESC-E the string would
be '<27>E'.rw DisplayString .1.3.6.1.4.1.683.6.3.1.4.22.1.5 |
tcpipMLPPostStringThis contains any data that should be sent down to the printer
at the end of jobs sent to this logical printer. To enter
non-printable ascii characters in the string, enclose the decimal
value inside of <>. For example, to enter an ESC-E the string would
be '<27>E'.rw DisplayString .1.3.6.1.4.1.683.6.3.1.4.22.1.6 |
tcpipMLPDeleteBytesThe number of bytes that will be deleted from the beginning of
jobs sent to this logical printer.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.22.1.7 |
tcpipSmtpServerAddrThe IP address of the e-mail server which will be used to send e-mail
notification of printer status conditions. This address must contain the
valid IP address of an e-mail server before any of the contents of the
SmtpTable are used.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.23 |
tcpipNumSmtpDestinationsThe number of configurable e-mail destinations to receive
printer status conditions.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.24 |
tcpipSmtpTableA list of SMTP e-mail addresses and printer status conditions
to send e-mails for. The number of entries is given by the
value of tcpipNumSmtpDestinations. SEQUENCE OF TcpipSmtpEntry .1.3.6.1.4.1.683.6.3.1.4.25 |
tcpipSmtpEntryAn entry in the tcpipSmtpTable. TcpipSmtpEntry .1.3.6.1.4.1.683.6.3.1.4.25.1 |
tcpipSmtpIndexA unique value for entry in the tcpipSmtpTable.
Its value ranges between 1 and the value of
tcpipNumSmtpDestinations.ro INTEGER .1.3.6.1.4.1.683.6.3.1.4.25.1.1 |
tcpipSmtpEmailAddrThis is the e-mail address that printer status conditions
are sent to. If this string is empty the status conditions will
not be sent.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.25.1.2 |
tcpipSmtpProtocolMaskThis is the 16 bit mask which determines which protocol
specific conditions will be sent out via e-mail.
Currently no protocol specific conditions are supported.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.25.1.3 |
tcpipSmtpPrinterMaskThis is the 16 bit mask which determines which printer
specific conditions will be sent out via e-mail.
A value of 65535 indicates that all printer specific
conditions should be reported via e-mail.
BIT CONDITION
0 On-line (Condition cleared)
1 Off-line
2 No printer attached
3 Toner Low
4 Paper Out
5 Paper Jam
6 Door Open
15 Printer Errorrw INTEGER .1.3.6.1.4.1.683.6.3.1.4.25.1.4 |
tcpipSmtpOutputMaskThis is the 16 bit mask which determines which physical
output ports will be checked when generating printer
specific conditions to be sent out via e-mail.
A value of 65535 indicates that all physical output ports
will generate e-mails upon a change in status.
BIT CONDITION
0 Port 1
1 Port 2
2 Port 3
3 Port 4
... ...rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.25.1.5 |
tcpipWebAdminNameThis is the admin name used by web configuration for login.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.26 |
tcpipWebAdminPasswordThis is the admin password used by web configuration for login.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.27 |
tcpipWebUserNameThis is the user name used by web configuration for login. Not
currently used.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.28 |
tcpipWebUserPasswordThis is the user password used by web configuration for login. Not
currently used.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.29 |
tcpipWebHtttpPortThe port number used to communicate over http. Must be between 0 and
65535. It must not be the same as any other port used. Other ports used are
20, 21, 23, 515, & raw port numbers (9100, 9101, ... if at default)rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.30 |
tcpipWebFaqURLThis is the URL for FAQ at the ESI (or other OEM) website.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.31 |
tcpipWebUpdateURLThis is the URL for finding firmware updates at the ESI
(or other OEM) website.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.32 |
tcpipWebCustomLinkNameThis is the name assigned to the custom link defined by the user.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.33 |
tcpipWebCustomLinkURLThis is the URL for a custom link specified by the user.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.34 |
tcpipPOP3ServerAddressThe IP address of the POP3 server from which email will be retrieved.
This address must contain the valid IP address of a POP3 server before
any attempts to retrieve email will be made.rw IpAddress .1.3.6.1.4.1.683.6.3.1.4.35 |
tcpipPOP3PollIntervalThe number of seconds between attempts to retrieve mail from the
POP3 server.rw INTEGER .1.3.6.1.4.1.683.6.3.1.4.36 |
tcpipPOP3UserNameThis is the user name for the print server's email account on
the POP3 server.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.37 |
tcpipPOP3PasswordThis is the password for the print server's email account on
the POP3 server.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.38 |
tcpipDomainNameThis is the Domain name used by POP3 and SMTP.rw OCTET STRING .1.3.6.1.4.1.683.6.3.1.4.39 |
tcpipStatus OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.1.5 |
tcpipErrorContains any tcpip specific error information.ro DisplayString .1.3.6.1.4.1.683.6.3.1.5.1 |
tcpipDisplayMaskBit mask describing what should be displayed by the utilities
bit Description
-
0 tcpipAddress (Includes tcpipDefaultGateway and tcpipSubnetMask)
1 tcpipUsingNetProtocols (Includes tcpipBootProtocolsEnabled, tcpipAddressSource, tcpipAddressServerAddress)
2 tcpipTimeoutChecking
3 tcpipTraps (Includes all trap info)
4 tcpipBanners
5 tcpipSecurity (Includes all security info)
6 tcpipWinsAddress (Includes tcpipWinsAddressSource)
7 tcpipConfigPassword
8 tcpipTimeoutCheckingValue
9 tcpipArpInterval
10 tcpipRawPortNumber
11 tcpipError
12 tcpipLowBandwidth
13 tcpipMLP (Includes all logical printer settings)ro INTEGER .1.3.6.1.4.1.683.6.3.1.6 |
netware OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.2 |
nwGroupVersionThe version for the netware group.ro INTEGER .1.3.6.1.4.1.683.6.3.2.1 |
nwEnabledIndicates whether or not the NetWare protocol stack is
enabled on the print server.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.2.2 |
nwCommands OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.2.3 |
nwRestoreDefaultsA value of 2 will restore all NetWare parameters on
the print server to factory defaults, as well as reset
the print server.rw Enumeration .1.3.6.1.4.1.683.6.3.2.3.1 |
nwFirmwareUpgradeA value of 2 will put the print server into firmware
upgrade mode.rw Enumeration .1.3.6.1.4.1.683.6.3.2.3.2 |
nwConfigure OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.2.4 |
nwFrameFormatIndicates the frame format that the print server is
using. See nwSetFrameFormat to determine which frame
frame format the print server is configured for.ro Enumeration .1.3.6.1.4.1.683.6.3.2.4.1 |
nwSetFrameFormatIndicates the frame format that the print server is
using. Setting this value to 1 (Auto_Sense) indicates
that automatic frame format sensing will be used.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.2.4.2 |
nwModeMode the print server is running in.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.2.4.3 |
nwPrintServerNameContains print server name.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.4 |
nwPrintServerPasswordThe print server password. This value cannot be read,
just set.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.5 |
nwQueueScanTimeDetermines how often, in tenths of a second that the
print server will scan the queues for jobs.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw INTEGER .1.3.6.1.4.1.683.6.3.2.4.6 |
nwNetworkNumberThe print server's network number.ro OCTET STRING .1.3.6.1.4.1.683.6.3.2.4.7 |
nwMaxFileServersThe print server maximum number of file servers which
it can be attached to at once.ro INTEGER .1.3.6.1.4.1.683.6.3.2.4.8 |
nwFileServerTableA table of file servers to service. SEQUENCE OF NwFileServerEntry .1.3.6.1.4.1.683.6.3.2.4.9 |
nwFileServerEntryA file server for the print server to service. NwFileServerEntry .1.3.6.1.4.1.683.6.3.2.4.9.1 |
nwFileServerIndexA unique value for each file server. Its value
ranges between 1 and the value of nwMaxFileServers.
The value for each server must remain constant at
least from one re-initialization of the entity's
network management system to the next
re-initialization. The first entry in the table is
the default file server.ro INTEGER .1.3.6.1.4.1.683.6.3.2.4.9.1.1 |
nwFileServerNameThe file server name. This name will be NULL if there
is no file server to be serviced. Only the default
file server (the first entry in the table) can be set.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.9.1.2 |
nwFileServerConnectionStatusThe value describes the status of the connection
between the file server and the print server.ro Enumeration .1.3.6.1.4.1.683.6.3.2.4.9.1.3 |
nwPortTableA table of NetWare port specific information. SEQUENCE OF NwPortEntry .1.3.6.1.4.1.683.6.3.2.4.10 |
nwPortEntryAn entry of NetWare port specific information. NwPortEntry .1.3.6.1.4.1.683.6.3.2.4.10.1 |
nwPortIndexA unique value for each physical output port. Its
value ranges between 1 and the value of outputNumPorts.
The value for each port must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization.ro INTEGER .1.3.6.1.4.1.683.6.3.2.4.10.1.1 |
nwPortStatusA string indicating the NetWare specific status of the
physical output port.ro DisplayString .1.3.6.1.4.1.683.6.3.2.4.10.1.2 |
nwPortPrinterNumberIndicates the printer number for the print server to
use when running in RPRinter mode. A value of 255
indicates that the port is unconfigured for RPRinter
mode.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw INTEGER .1.3.6.1.4.1.683.6.3.2.4.10.1.3 |
nwPortFontDownloadThis variable controls the font downloading feature
of the print server.
Disabled - Do not download fonts.
Enabled, without Printer Sense - Only download fonts
after the print server has been reset or power cycled.
Enabled, with Printer Sense - Download fonts after the
print server has been reset or power-cycled, or after
the printer has been power-cycled. This option is only
available on certain print servers.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.2.4.10.1.4 |
nwPortPCLQueueA string indicating the name of the queue containing
the PCL fonts to download when font downloading is
enabled.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.10.1.5 |
nwPortPSQueueA string indicating the name of the queue containing
the PS fonts to download when font downloading is
enabled.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.10.1.6 |
nwPortFormsOnA value of 2 will enable forms checking.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.2.4.10.1.7 |
nwPortFormNumberIndicates the form number to check jobs against
when nwPortFormsOn is enabled.rw INTEGER .1.3.6.1.4.1.683.6.3.2.4.10.1.8 |
nwPortNotificationA value of 2 will enable job notification.rw Enumeration .1.3.6.1.4.1.683.6.3.2.4.10.1.9 |
nwNumTrapsThe number of IPX trap destinations.ro INTEGER .1.3.6.1.4.1.683.6.3.2.4.11 |
nwTrapTableA list of IPX trap definitions. The number of
entries is given by the value of nwNumTraps. SEQUENCE OF NwTrapEntry .1.3.6.1.4.1.683.6.3.2.4.12 |
nwTrapEntryAn entry in the nwTrapTable. NwTrapEntry .1.3.6.1.4.1.683.6.3.2.4.12.1 |
nwTrapIndexA unique value for entry in the nwTrapTable.
Its value ranges between 1 and the value of
nwNumTraps.ro INTEGER .1.3.6.1.4.1.683.6.3.2.4.12.1.1 |
nwTrapDestinationThis is the network address that IPX traps are sent to.
A value of 00 00 00 00 00 00 in conjunction with a
nwTrapDestinationNet of 00 00 00 00 will disable traps
over IPX.rw OCTET STRING .1.3.6.1.4.1.683.6.3.2.4.12.1.2 |
nwTrapDestinationNetThis is the network number that IPX traps are sent to.
A value of 00 00 00 00 in conjunction with a
nwTrapDestination of 00 00 00 00 00 00 will disable
traps over IPX.rw OCTET STRING .1.3.6.1.4.1.683.6.3.2.4.12.1.3 |
nwProtocolTrapMaskThis is the 16 bit mask which determines which protocol
specific traps will be sent out via IPX.
Currently no protocol specific traps are supported.rw INTEGER .1.3.6.1.4.1.683.6.3.2.4.12.1.4 |
nwPrinterTrapMaskThis is the 16 bit mask which determines which printer
specific traps will be sent out via IPX.
A value of 65535 indicates that all printer specific
traps should be reported via IPX.
BIT CONDITION
0 On-line (Condition cleared)
1 Off-line
2 No printer attached
3 Toner Low
4 Paper Out
5 Paper Jam
6 Door Open
15 Printer Errorrw INTEGER .1.3.6.1.4.1.683.6.3.2.4.12.1.5 |
nwOutputTrapMaskThis is the 16 bit mask which determines which physical
output ports will be checked when generating printer
specific traps to be sent out via IPX.
A value of 65535 indicates that all physical output ports
will generate traps.
BIT CONDITION
0 Port 1
1 Port 2
2 Port 3
3 Port 4
... ...rw INTEGER .1.3.6.1.4.1.683.6.3.2.4.12.1.6 |
nwNDSPrintServerNameDirectory Services object used by the print server to
connect to the NDS tree. This string contains the entire
canonicalized name.
NOTE: This variable must be stored in Unicode.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.13 |
nwNDSPreferredDSTreeDirectory Services tree to which the NDS print server
initially connects.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.14 |
nwNDSPreferredDSFileServerThe NetWare server to which the NDS print server initially
makes a bindery connection.rw DisplayString .1.3.6.1.4.1.683.6.3.2.4.15 |
nwNDSPacketCheckSumEnabledCompute the checksum for packets.
1 = disabled
2 = enabledrw INTEGER .1.3.6.1.4.1.683.6.3.2.4.16 |
nwNDSPacketSignatureLevelPacket signature is a security method to prevent
packet forging.
1 = disabled
2 = enabled
3 = preferred
4 = requiredrw INTEGER .1.3.6.1.4.1.683.6.3.2.4.17 |
nwAvailablePrintModesReports which NetWare print modes are available.
BIT CONDITION
0 PServer
1 RPrinter
2 NDS
3 SPX Direct
4 JetAdminro INTEGER .1.3.6.1.4.1.683.6.3.2.4.18 |
nwDirectPrintEnabledIndicates whether or not direct mode ipx/spx
printing is enabled.rw Enumeration .1.3.6.1.4.1.683.6.3.2.4.19 |
nwJAConfigIndicates whether or not JetAdmin was used to configure
the netware settings.ro Enumeration .1.3.6.1.4.1.683.6.3.2.4.20 |
nwDisableSAPIndicates whether or not SAPs are enabled.rw Enumeration .1.3.6.1.4.1.683.6.3.2.4.21 |
nwStatus OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.2.5 |
nwErrorContains any NetWare specific error information.ro DisplayString .1.3.6.1.4.1.683.6.3.2.5.1 |
nwDisplayMaskBit mask describing what should be displayed by the utilities
bit Description
-
0 nwFrameFormat
1 nwJetAdmin
2 nwFileServer (Includes all file server info)
3 nwMode
4 nwPrintServerName
5 nwPrintServerPassword
6 nwQueueScanTime
7 nwNetworkNumber
8 nwPortStatus
9 nwPortPrinterNumber
10 nwPortFontDownload (Includes nwPortPCLQueue and nwPortPSQueue)
11 nwPortFormsOn (Includes nwPortFormsNumber)
12 nwPortNotification
13 nwTraps (Includes all trap info)
14 nwNDSPrintServerName
15 nwNDSPreferredDSTree
16 nwNDSPreferredDSFileServer
17 nwNDSPacketCheckSumEnabled
18 nwNDSPacketSignatureLevel
19 nwDirectPrintEnabled
20 nwError
21 nwSapDisablero INTEGER .1.3.6.1.4.1.683.6.3.2.6 |
vines OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.3 |
bvGroupVersionThe version for the vines group.ro INTEGER .1.3.6.1.4.1.683.6.3.3.1 |
bvEnabledIndicates whether or not the Banyan VINES protocol
stack is enabled on the print server.rw Enumeration .1.3.6.1.4.1.683.6.3.3.2 |
bvCommands OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.3.3 |
bvRestoreDefaultsA value of 2 will restore all VINES parameters on
the print server to factory defaults, as well as reset
the device.rw Enumeration .1.3.6.1.4.1.683.6.3.3.3.1 |
bvFirmwareUpgradeA value of 2 will put the print server into firmware
upgrade mode.rw Enumeration .1.3.6.1.4.1.683.6.3.3.3.2 |
bvSetSequenceRoutingSets the VINES Routing selection.
Automatic - Utilizes Sequenced Routing if available,
otherwise uses Non-Sequenced Routing.
Force-Sequenced - Will only use Sequenced Routing.
Force-Non-Sequenced - Will only use Non-Sequenced Routing
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.
WARNING - Sequential Routing requires a VINES 5.5 or
greater server on the same subnet.rw Enumeration .1.3.6.1.4.1.683.6.3.3.3.3 |
bvDisableVPManA value of 2 will disable VPMan access to the print
server for one minute.rw Enumeration .1.3.6.1.4.1.683.6.3.3.3.4 |
bvConfigure OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.3.4 |
bvLoginNameThe StreetTalk name the device will use to login with.
This value will be ESIxxxxxxxx where xxxxxxx is the Serial
number of the device if it is unconfigured.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.3.4.1 |
bvLoginPasswordThe password for the login name, bvLoginName. This value
cannot be read, just set.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.3.4.2 |
bvNumberPrintServicesThe number of Print Services this device supports.ro INTEGER .1.3.6.1.4.1.683.6.3.3.4.3 |
bvPrintServiceTableTable of Print Services for this device. SEQUENCE OF BvPrintServiceEntry .1.3.6.1.4.1.683.6.3.3.4.4 |
bvPrintServiceEntryPrint Services Table entry. BvPrintServiceEntry .1.3.6.1.4.1.683.6.3.3.4.4.1 |
bvPrintServiceIndexA unique value for each print service.ro INTEGER .1.3.6.1.4.1.683.6.3.3.4.4.1.1 |
bvPrintServiceNameThe StreetTalk Name for this Print Service.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw DisplayString .1.3.6.1.4.1.683.6.3.3.4.4.1.2 |
bvPrintServiceRoutingThe output port that the print service will print to.
This value will range from 0 to the number of output ports,
see outputNumPorts.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw INTEGER .1.3.6.1.4.1.683.6.3.3.4.4.1.3 |
bvPnicDescriptionContains the VINES PNIC description.rw DisplayString .1.3.6.1.4.1.683.6.3.3.4.5 |
bvStatus OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.3.5 |
bvErrorContains any VINES specific error information.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.1 |
bvRoutingThe current VINES Routing being used by the device.ro Enumeration .1.3.6.1.4.1.683.6.3.3.5.2 |
bvNumPrintServicesThe number of Print Services this device supports.ro INTEGER .1.3.6.1.4.1.683.6.3.3.5.3 |
bvPrintServiceStatusTableTable of Print Service Status Entry's. SEQUENCE OF BvPrintServiceStatusEntry .1.3.6.1.4.1.683.6.3.3.5.4 |
bvPrintServiceStatusEntryPrint Service Status Entry. BvPrintServiceStatusEntry .1.3.6.1.4.1.683.6.3.3.5.4.1 |
bvPSStatusIndexA unique value for each status entry.ro INTEGER .1.3.6.1.4.1.683.6.3.3.5.4.1.1 |
bvPSNameThe StreetTalk Name for this Print Service.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.4.1.2 |
bvPSStatusPrint Service Status.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.4.1.3 |
bvPSDestinationPort Destination for this print service.ro INTEGER .1.3.6.1.4.1.683.6.3.3.5.4.1.4 |
bvPrinterStatusPrinter status for this Print Service.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.4.1.5 |
bvJobActiveWhether there is a VINES job active for this print
service.ro Enumeration .1.3.6.1.4.1.683.6.3.3.5.4.1.6 |
bvJobSourceThe active print jobs source.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.4.1.7 |
bvJobTitleThe title of the active print job.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.4.1.8 |
bvJobSizeThe size of the active print job.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.4.1.9 |
bvJobNumberThe VINES job number of the active print job.ro DisplayString .1.3.6.1.4.1.683.6.3.3.5.4.1.10 |
lanManager OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.4 |
lmGroupVersionThe version for the lanManger group.ro INTEGER .1.3.6.1.4.1.683.6.3.4.1 |
lmEnabledIndicates whether or not the Lan Manager protocol
stack is enabled on the print server.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.4.2 |
eTalk OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.5 |
eTalkGroupVersionThe version for the eTalk group.ro INTEGER .1.3.6.1.4.1.683.6.3.5.1 |
eTalkEnabledIndicates whether or not the EtherTalk protocol
stack is enabled on the print server.
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.rw Enumeration .1.3.6.1.4.1.683.6.3.5.2 |
eTalkCommands OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.5.3 |
eTalkRestoreDefaultsA value of 2 will restore all EtherTalk parameters on
the print server to factory defaults, as well as reset
the print server.rw Enumeration .1.3.6.1.4.1.683.6.3.5.3.1 |
eTalkConfigure OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.5.4 |
eTalkNetworkIndicates the EtherTalk network number that the print
server is currently using.ro OCTET STRING .1.3.6.1.4.1.683.6.3.5.4.1 |
eTalkNodeIndicates the EtherTalk node number that the print
server is currently using.ro OCTET STRING .1.3.6.1.4.1.683.6.3.5.4.2 |
eTalkNumPortsIndicates the number of physical output ports that
are EtherTalk compatible.ro INTEGER .1.3.6.1.4.1.683.6.3.5.4.3 |
eTalkPortTableA table of EtherTalk specific port configuration
information. SEQUENCE OF ETalkPortEntry .1.3.6.1.4.1.683.6.3.5.4.4 |
eTalkPortEntryAn entry of EtherTalk port specific information. ETalkPortEntry .1.3.6.1.4.1.683.6.3.5.4.4.1 |
eTalkPortIndexA unique value for each physical output port which is
compatible with EtherTalk. Its value ranges between
1 and the value of eTalkNumPorts. The value for each
port must remain constant at least from one
re-initialization of the entity's network management
system to the next re-initialization.ro INTEGER .1.3.6.1.4.1.683.6.3.5.4.4.1.1 |
eTalkPortEnableIndicates whether or not the physical output port is
enabled to print via EtherTalk and will show up in the
Chooser.rw Enumeration .1.3.6.1.4.1.683.6.3.5.4.4.1.2 |
eTalkNameThis is the EtherTalk name for the print server.rw DisplayString .1.3.6.1.4.1.683.6.3.5.4.4.1.3 |
eTalkActiveNameThis is the EtherTalk name for the print server
that is currently being used.ro DisplayString .1.3.6.1.4.1.683.6.3.5.4.4.1.4 |
eTalkType1Indicates the first EtherTalk type. This type is
mandatory.rw DisplayString .1.3.6.1.4.1.683.6.3.5.4.4.1.5 |
eTalkType2Indicates the second EtherTalk type. This type is
optional. Setting this name to NULL will disable it.rw DisplayString .1.3.6.1.4.1.683.6.3.5.4.4.1.6 |
eTalkZoneIndicates the EtherTalk zone. This must be defined
on the router.rw DisplayString .1.3.6.1.4.1.683.6.3.5.4.4.1.7 |
eTalkActiveZoneIndicates the EtherTalk zone that is currently being
used. This must be defined on the router.ro DisplayString .1.3.6.1.4.1.683.6.3.5.4.4.1.8 |
eTalkStatus OBJECT IDENTIFIER .1.3.6.1.4.1.683.6.3.5.5 |
eTalkErrorShows any errors for the EtherTalk protocol.ro DisplayString .1.3.6.1.4.1.683.6.3.5.5.1 |