Home/Catalog/EGENERA-MIB

EGENERA-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for EGENERA-MIB.

1246
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

1246 total
Object Name
egenera
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559
RFC-1215
Unknown
.1.3.6.1.4.1.7559
bladeFrameUpTrapThe notification generated when a BladeFrame enters the Egenera PAN (generally when powered on). This trap is driven by the 'frame.discover' event type. This event type occurs early during PAN Manager startup, and indicates that the BladeFrame has been discovered and that the physical model is being constructed. This trap is primarily intended for environments where multiple BladeFrames are managed in the same PAN, however multi- BladeFrame management is not yet supported. This event type is not user visible, and will not appear in CLI or GUI event queries. The trap exists to satisfy early requirements documents. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.101
bladeFrameDownTrapThe notification generated when a BladeFrame departs the Egenera PAN (generally when powered off). This trap is currently not driven by any event, and thus is not emmitted. The trap is intended to communicate when a BladeFrame departs from a BladeFarm in environments where multiple BladeFrames are managed in the same PAN, however multi-BladeFrame management is not yet supported. The trap exists to satisfy early requirements documents.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.102
bladeFrameDeviceIdMismatchTrapThe notification generated Master and Slave cBlades do not agree on SCSI device IDs. This trap is driven by the 'PAN Manager Device ID Mismatch' event type. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.103
bladeFramePowerOverCommitTrapThe notification generated when a power domain has been overcommited. This trap is driven by 'BladeFrame <framename> Power Domain <A|B|C|D> Over Attached Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.104
bladeFramePowerOverDrawTrapThe notification generated when a power domain has been over drawn. This trap is driven by 'BladeFrame <framename> Power Domain <A|B|C|D> Over Powered Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.105
bladeFramePowerDeniedTrapThe notification generated when a blade power-on is denied due to lack of power. This trap is driven by 'BladeFrame <framename> Power Domain <A|B|C|D> Power On Denied Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.106
bfArchiveCreateTrapThe notification generated when an archive has been created. This trap is driven by the 'Archive creation' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.107
bfArchiveDeleteTrapThe notification generated when an archive has been deleted. This trap is driven by the 'Archive deletion' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.108
bfArchiveSchedCreateTrapThe notification generated when an archive schedule has been created. This trap is driven by the 'Archive schedule creation' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.109
bfArchiveSchedDeleteTrapThe notification generated when an archive schedule has been deleted. This trap is driven by the 'Archive schedule deletion' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.110
bfArchiveSchedFailedTrapThe notification generated when a scheduled archive fails in the PAN. This trap is driven by the 'Archive schedule failed' event type. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.111
bfArchiveSchedModifiedTrapThe notification generated when an archive schedule has been modified. This trap is driven by the 'Archive schedule modification' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.112
bfArchiveSchedRunningTrapThe notification generated when an archive schedule is run. This trap is driven by the 'Archive schedule running' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.113
bladeFrameMasterRecoveredTrapThe notification generated when a BladeFrame is available after a failover . This trap is driven by the 'BladeFrame Master Recovered Event' event type. This trap is deprecate as of 4.0.0. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.114
bladeFrameREthMisconfigTrapThe notification generated when a REth misconfiguration is detected. This trap is driven by the 'Reth Misconfiguration Event' event type. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.115
bfPANManagerDowntimeTrapThe notification generated when a PAN Manager reports its own downtime. This trap is driven by the 'PAN Manager <bladeframe>/c<1|2> Downtime Report Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.116
bfRccReportPeriodStartTrapThe notification generated when the Resource Configuration Collector begins a reporting period. This trap is driven by the 'RCC Reporting Period Started Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.117
bfRccReportPeriodEndTrapThe notification generated when the Resource Configuration Collector ends a reporting period. This trap is driven by the 'RCC Reporting Period Ended Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.118
bfRccExpiredFilesDeletedTrapThe notification generated when the Resource Configuration Collector deletes expired files. This trap is driven by the 'RCC Expired Files Deleted' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.119
chassisOOBFailureTrapThe notification generated when there is a failure to execute an Out of Band control operation on the chassis. This trap is driven by the 'Chassis OOB Failure' event type. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.120
bladeFramePanJoinTrapThe notification generated when the bladeFrame joined PAN. This trap is driven by the 'PAN Join Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.120
bladeDiscoveryCompletedTrapThe notification generated when we finish the hardware discovery process of a blade successfully. This trap will not be generated on all hardware platforms. This trap is driven by the 'Blade Discovery Completed' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.121
bladeDiscoveryFailedTrapThe notification generated when we finish the hardware discovery process of a blade unsuccessfully. This trap will not be generated on all hardware platforms. This trap is driven by the 'Blade Discovery Failed' event type. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.122
bladeUndiscoveryCompletedTrapThe notification generated when we finish the hardware undiscovery process of a blade successfully. This trap will not be generated on all hardware platforms. This trap is driven by the 'Blade Undiscovery Completed' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.123
bladeUndiscoveryFailedTrapThe notification generated when we finish the hardware undiscovery process of a blade unsuccessfully. This trap will not be generated on all hardware platforms. This trap is driven by the 'Blade Undiscovery Failed' event type. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.124
bfIArchiveExportStartTrapThe notification generated when a blade frame image archive export starts. This trap is driven by the 'Image Archive Export Start' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.125
bfIArchiveExportFinishTrapThe notification generated when a blade frame image archive export finishes. This trap is driven by the 'Image Archive Export Finish' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.126
bfIArchiveExportFailureTrapThe notification generated when a blade frame image archive export fails. This trap is driven by the 'Image Archive Export Failure' event type. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.127
bfIArchiveRestoreStartTrapThe notification generated when a blade frame image archive restore starts. This trap is driven by the 'Image Archive Restore Start' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.128
bfIArchiveRestoreFinishTrapThe notification generated when a blade frame image archive restore finishes. This trap is driven by the 'Image Archive Restore Finish' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.129
bfIArchiveRestoreFailureTrapThe notification generated when a blade frame image archive restore fails. This trap is driven by the 'Image Archive Restore Failure' event type. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.130
licenseAcquiredTrapThe notification generated when a license is used / acquired. This trap is driven by the 'License Acquired' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.131
licenseReleasedTrapThe notification generated when a license is released. This trap is driven by the 'License Released' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.132
licenseAcquireFailedTrapThe notification generated when a license acquire attempt fails. This trap is driven by the 'License Acquire Failed' event type. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.133
licenseAddedTrapThe notification generated when a license is added. This trap is driven by the 'License Added' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.134
licenseUpdatedTrapThe notification generated when a license is updated. This trap is driven by the 'License Updated' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.135
licenseRemovedTrapThe notification generated when a license is removed. This trap is driven by the 'License Removed' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.136
licenseInvalidTrapThe notification generated when a license is found to be invalid. This trap is driven by the 'License Invalid' event type. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.137
rethStatusRedundantTrapThe notification when a Redundant Ethernet transitions to the Redundant state (both Eths are known not to be Failed). This trap is driven by the 'reth <rethname> Redundant Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.150
rethStatusNotRedundantTrapThe notification when a Redundant Ethernet transitions to the Not-Redundant state (One Eth is known not to be Failed, the other Eth is either Failed or Unknown). This trap is driven by the 'reth <rethname> Not-Redundant Event' event type. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.151
rethStatusDegradedTrapThe notification when a Redundant Ethernet transitions to the Degraded state (One Eth is known to be Failed, the other Eth is Unknown). This trap is driven by the 'reth <rethname> Degraded Event' event type. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.152
rethStatusFailedTrapThe notification when a Redundant Ethernet transitions to the Failed state (both Eths are known to be Failed). This trap is driven by the 'reth <rethname> Failed Event' event type. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.153
cBladeInsertedTrapThe notification generated when a cBlade is inserted into a BladeFrame. This trap is driven by 'BladeFrame <framename> Blade Inserted Event' event types that describe cBlade insertions. Since the underlying event type describes pBlade, cBlade, and sBlade insertions, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeInsertedTrap and sBladeInsertedTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.201
cBladeRemovedTrapThe notification generated when a cBlade is removed from a BladeFrame. This trap is driven by 'BladeFrame <framename> Blade Removed Event' event types that describe cBlade removal events. Since the underlying event type describes pBlade, cBlade, and sBlade removal, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeRemovedTrap and sBladeRemovedTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.202
cBladePowerOnTrapThe notification generated when a cBlade is powered on. This trap is driven by 'Blade <framename>/c<1|2> Power Status Event' event types describing power on events. Since the underlying event type describes cBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePowerOffTrap. On BladeFrame ES Systems, this event type also comminicates power events for the cBlade daughter switch card, and thus enabling/disabling this trap is bound to enabling/disabling cBladeSwitchCardOnTrap and cBladeSwitchCardOffTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.203
cBladePowerOffTrapThe notification generated when a cBlade is powered off. This trap is driven by 'Blade <framename>/c<1|2> Power Status Event' event types describing power off events. Since the underlying event type describes cBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePowerOnTrap. On BladeFrame ES Systems, this event type also comminicates power events for the cBlade daughter switch card, and thus enabling/disabling this trap is bound to enabling/disabling cBladeSwitchCardOnTrap and cBladeSwitchCardOffTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.204
cBladeBootedTrapThe notification generated when a cBlade has successfully booted. This trap is driven by 'blade.status.monitor.event' event types that describe a cBlade transition from the booting state to the running state. This event type is not user visible, and will not appear in CLI or GUI event queries. The trap exists to satisfy early requirements documents. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.205
cBladeShutdownTrapThe notification generated when a cBlade has been shut down. This trap is driven by 'blade.status.monitor.event' event types that describe a cBlade transition from the shutting down state to the shutdown state. This event type is not user visible, and will not appear in CLI or GUI event queries. The trap exists to satisfy early requirements documents. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.206
cBladeEnabledTrapThe notification generated when a cBlade has been enabled (returns to service). This trap is driven by 'Blade <framename>/c<1|2> Out of Service Status false Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.207
cBladeDisabledTrapThe notification generated when a cBlade has been disabled (removed from service). This trap is driven by 'Blade <framename>/c<1|2> Out of Service Status true Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.208
cBladeSelectedTrapThe notification generated when a cBlade has been selected. This trap is driven by 'Blade <framename>/c<1|2> Selected Status true Event' even types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.209
cBladeDeselectedTrapThe notification generated when a cBlade has been unselected. This trap is driven by 'Blade <framename>/c<1|2> Selected Status false Event' even types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.210
cBladeMasterTrapThe notification generated when a cBlade has assumed the role of PAN Master. This trap is driven by 'PAN Manager <framename>/c<1|2> Start Event' event types that describe PAN Master initialization. Since the underlying event type describes PAN Manager started and master or slave initialization, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeSlaveTrap and cBladePanManagerStartedTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.211
cBladeSlaveTrapThe notification generated when a cBlade has assumed the role of a PAN Slave. This trap is driven by 'PAN Manager <framename>/c<1|2> Start Event' event types that describe PAN Slave initialization. Since the underlying event type describes PAN Manager started and master or slave initialization, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeMasterTrap and cBladePanManagerStartedTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.212
cBladeHwEventTrapEncapsulates generic events from hardware. This trap is driven by 'Blade <framename>/c<1|2> non-sensor Event' event types that do not indicate panic, commanded shutdown, commanded reboot, or init level events. Examples message contents include: OEM Type 0xe0, value = 0x64:0x21:0xce:0xe0:0x1d:0x00:0x00:0x00... bmc reset deasserted, value = 0x0211 system booted Contact EES for more specific information. Since the underlying event type describes cBlade all non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePanicTrap, cBladeCmdShutdownTrap, cBladeCmdRebootTrap, cBladeCmdHaltTrap, and cBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.213
cBladeSwitchCardOnTrapInicates the daughter switch card of cBladeES blades has been powered on. This trap is only emitted from BladeFrame ES systems. This trap is driven by 'Blade <framename>/c<1|2> Power Status Event' event types describing cBladeES daughter switch card power on events. Since the underlying event type describes cBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeSwitchCardOffTrap, cBladePowerOnTrap, and cBladePowerOffTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.215
cBladeSwitchCardOffTrapInicates the daughter switch card of cBladeES blades has been powered on. This trap is only emitted from BladeFrame ES systems. This trap is driven by 'Blade <framename>/c<1|2> Power Status Event' event types describing cBladeES daughter switch card power off events. Since the underlying event type describes cBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeSwitchCardOnTrap, cBladePowerOnTrap, and cBladePowerOffTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.216
cBladeFailureTrapThe notification generated when a cBlade fails. This trap is driven by 'PAN Manager cBlade Failure Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.217
cBladeMasterFailoverTrapThe notification generated when a cBlade has assumed the role of PAN Master after a failover. This trap is driven by 'PAN Manager <framename>/c<1|2> Failover Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.218
cBladeStonithTrapThe notification generated when one cBlade has stonithed the other. This trap is driven by 'PAN Manager cBlade Stonithed Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.219
cBladeSyslogEventTrapThe notification sent when a syslog target string is emmited from the system logger. This trap is driven by 'Blade <framename>/c<1|2> Custom Linux System Message <1..10>' event types. See 'eventtype -l' for more information. There are 10 cBlade syslog event types. This trap can be enabled/disabled for each syslog event type independently. Severity: (configurable by EES, generally 1, 2 or 3)
TRAP-TYPE
.1.3.6.1.4.1.7559.0.220
cBladeSyslogDroppedTrapThe notification sent when a syslog target string message is dropped due to rate limiting. This trap is driven by 'Blade <framename>/c<1|2> Custom Linux System Messages dropped' event types. System message events are subject to rate limiting. By default, no more than 5 messages can be emitted during a 5 minute period. If more than 5 target strings are encountered, events will only be created for the first 5 messages, subsequent messages will be dropped. At the end of the 5 minute period, a 'Messages Dropped' event will be emmitted to indicate the number of dropped messages during the 5 minute period. Contact EES for more information. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.221
cBladeSyslogPollingStoppedTrapThe notification sent when a syslog polling has stopped due to rate limiting. This trap is driven by the 'Blade MyBladeFrame/c1 Custom Linux System Messages polling stopped' event type. System message events are subject to rate limiting. By default, no more than 5 messages can be emitted during a 5 minute period. If more than 5 target strings are encountered, events will only be created for the first 5 messages, subsequent messages will be dropped. If messages are dropped for 5 consecutive 5 minute periods, syslog message polling will be disabled on that cBlade. Contact EES for more information. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.222
cBladePedDeadlockTrapPED deadlock message. This trap is driven by 'Blade <framename>/c<1|2> PED Deadlock Avoidance Message' event types. This trap encapsulates the following PED message types: EM24585 EM24586 Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.223
cBladePedFabricTrapPED fabric message. This trap is driven by 'Blade <framename>/c<1|2> PED Fabric Message event types. This trap encapsulates the following PED message types: EM16387 EM16388 EM16389 EM16390 EM16391 EM16392 EM24576 EM24580 EM24581 EM24582 EM24583 EM24584 EM24587 EM24588 EM24589 EM24590 EM24591 EM24592 Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.224
cBladePedLegacyTrapPED legacy message This trap is driven by 'Blade <framename>/c<1|2> PED Legacy Message event types. This trap encapsulates the following PED message types: EM24595 Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.225
cBladePedOtherTrapPED other message. This trap is driven by 'Blade <framename>/c<1|2> PED Message' event types. This trap encapsulates any PED message not contained in any other specific PED event/trap types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.226
cBladePedNodeTrapPED node message. This trap is driven by 'Blade <framename>/c<1|2> PED Node Message' event types. This trap encapsulates the following PED message types: EM16385 EM16386 Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.227
cBladePedPathErrorTrapPED path error message. This trap is driven by 'Blade <framename>/c<1|2> PED Path Error Message' event types. This trap encapsulates the following PED message types: EM24593 EM24594 Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.228
cBladePedSerialBitTrapPED serial bit message. This trap is driven by 'Blade <framename>/c<1|2> PED Serial Bit Message' event types. This trap encapsulates the following PED message types: EM24577 EM24578 EM24579 Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.229
cBladePedSwitchTrapPED serial bit message. This trap is driven by 'Blade <framename>/c<1|2> PED Switch Message' event types. This trap encapsulates the following PED message types: EM16384 EM16393 EM16394 EM16395 EM16396 EM16397 EM16398 EM16399 EM16400 Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.230
cBladePanicTrapEncapsulates hardware events identifying cBlade panics that cause the cBlade to enter KDB, reboot, or halt' This trap is driven by 'Blade <framename>/c<1|2> non-sensor Event' event types that describe kernel panics. Contact EES for more specific information. Since the underlying event type describes cBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeHwEventTrap, cBladeCmdShutdownTrap, cBladeCmdRebootTrap, cBladeCmdHaltTrap, and cBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.231
cBladeCmdHaltTrapEncapsulates hardware events indicating intentional cBlade halt. This trap is driven by 'Blade <framename>/c<1|2> non-sensor Event' event types that describe commanded halts. Contact EES for more specific information. Since the underlying event type describes cBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeHwEventTrap, cBladeCmdShutdownTrap, cBladeCmdRebootTrap, cBladePanicTrap, and cBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.232
cBladeCmdRebootTrapEncapsulates hardware events indicating intentional cBlade reboot. This trap is driven by 'Blade <framename>/c<1|2> non-sensor Event' event types that describe commanded reboots. Contact EES for more specific information. Since the underlying event type describes cBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeHwEventTrap, cBladeCmdShutdownTrap, cBladeCmdHaltTrap, cBladePanicTrap, and cBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.233
cBladeInitTrapEncapsulates hardware events indicating intentional cBlade has reached an init level. This trap is driven by 'Blade <framename>/c<1|2> non-sensor Event' event types that describe init level reached. Contact EES for more specific information. Since the underlying event type describes cBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeHwEventTrap, cBladeCmdShutdownTrap, cBladeCmdHaltTrap, cBladeCmdRebootTrap, and cBladePanicTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.234
cBladeVoltageUpperTrapEncapsulates cBlade critical high voltage sensor events. This trap is driven by 'Blade <framename>/c<1|2> <voltage-sensor-name> Critical High Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces cBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.235
cBladeVoltageLowerTrapEncapsulates cBlade critical low voltage sensor events. This trap is driven by 'Blade <framename>/c<1|2> <voltage-sensor-name> Critical Low Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces cBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.236
cBladeFanSpeedUpperTrapEncapsulates cBlade critical high fan speed sensor events. This trap is driven by 'Blade <framename>/c<1|2> <fan-sensor-name> Critical High Event' event types. This trap replaces cBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.237
cBladeFanSpeedLowerTrapEncapsulates cBlade critical low fan speed sensor events. This trap is driven by 'Blade <framename>/c<1|2> <fan-sensor-name> Critical Low Event' event types. This trap replaces cBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.238
cBladeTempUpperTrapEncapsulates cBlade critical high temperature sensor events. This trap is driven by 'Blade <framename>/c<1|2> <temp-sensor-name> Critical High Event' event types. This trap replaces cBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.239
cBladeTempLowerTrapEncapsulates cBlade critical low temperature sensor events. This trap is driven by 'Blade <framename>/c<1|2> <temp-sensor-name> Critical Low Event' event types. This trap replaces cBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.240
cBladePowerOnOpTrapEncapsulates cBlade power on operation event. This trap is driven by 'cBlade <framename>/c<1|2> Hardware Operation Event' event types. Since the underlying event type describes cBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePowerOffOpTrap, cBladePowerCycleTrap, cBladeResetOpTrap, and cBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.241
cBladePowerOffOpTrapEncapsulates cBlade power off operation event. This trap is driven by 'cBlade <framename>/c<1|2> Hardware Operation Event' event types. Since the underlying event type describes cBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePowerOnOpTrap, cBladePowerCycleTrap, cBladeResetOpTrap, and cBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.242
cBladePowerCycleOpTrapEncapsulates cBlade power cycle operation event. This trap is driven by 'cBlade <framename>/c<1|2> Hardware Operation Event' event types. Since the underlying event type describes cBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePowerOnOpTrap, cBladePowerCycleTrap, cBladeResetOpTrap, and cBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.243
cBladeResetOpTrapEncapsulates cBlade reset operation event. This trap is driven by 'cBlade <framename>/c<1|2> Hardware Operation Event' event types. Since the underlying event type describes cBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePowerOnOpTrap, cBladePowerCycleTrap, cBladePowerCycleOpTrap, and cBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.244
cBladeNMIOpTrapEncapsulates cBlade reset operation event. This trap is driven by 'cBlade <framename>/c<1|2> Hardware Operation Event' event types. Since the underlying event type describes cBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladePowerOnOpTrap, cBladePowerCycleTrap, cBladePowerCycleOpTrap, and cBladeResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.245
cBladePedErrorTrapPED error message. This trap is driven by 'Blade <framename>/c<1|2> PED Error Message' event types. This trap encapsulates the following PED message types: EM24596 EM24597 EM24598 Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.246
cBladeSystemThresholdHighTrapThe notification generated when a cBlade system monitor has exceeded its high threshold, or returns below the high threshold. This trap is driven by 'cBlade <bladeframe>/c<1|2> <monitorname> event' event types. Note that a severity 3 event is emmitted when the threshold is crossed in the rising direction, while a severity 5 event is emmitted when the monitored value returns below the threshold. Thus it is possible to recieve a severity 5 cBladeSystemThresholdHighTrap with a message like: sagan/c1 5 Minute Load Average returned below 10.0 on average for 300 seconds, Current value = 4.79 Severity: 3/5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.250
cBladeNonFatalHwErrorTrapThe notification generated when cBlade hardware detects a non-fatal error, such as a correctable ECC memory error. This trap is driven by 'cBlade <bladeframe>/c<1|2> NonFatal Hardware Error Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.251
cBladeFatalHwErrorTrapThe notification generated when cBlade hardware detects a fatal error, such as an uncorrectable ECC memory error. This trap is driven by 'cBlade <bladeframe>/c<1|2> Fatal Hardware Error Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.252
cBladePanManagerStartedTrapThe notification generated when the PAN Manager has been started on a cBlade. This trap is driven by 'PAN Manager <bladeframe>/c<1|2> Start Event' event types that do not indicate Master or Slave initialization. Since the underlying event type describes PAN Manager started and master or slave initialization, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of cBladeMasterTrap and cBladeSlaveTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.253
cBladeNonUniqueDiskIdTrapThe notification generated when a cBlade detects multiple disks with the same Unique ID. This trap is driven by 'Non-unique disk ID Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.254
cBladeOutOfServicePendingTrapThe notification generated when a cBlade enters the 'out of service pending' state. This trap is driven by 'cBlade <bladeframe>/c<1|2> Out of Service Pending Event' event types Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.255
cBladeDiskIOAvailableTrapThe notification generated when disk I/O becomes available on a cBlade. This trap is driven by 'Device IO Available Event' event types that describe Disk I/O availability. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.256
cBladeDiskIOUnvailableTrapThe notification generated when disk I/O becomes unavailable on a cBlade. This trap is driven by 'Device IO Unvailable Event' event types that describe disk I/O unavailability. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.257
cBladeEthIOAvailableTrapThe notification generated when ethernet I/O becomes available on a cBlade. This trap is driven by 'Device IO Available Event' event types that describe ethernet I/O availability. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.258
cBladeEthIOUnvailableTrapThe notification generated when ethernet I/O becomes unavailable on a cBlade. This trap is driven by 'Device IO Unvailable Event' event types that describe ethernet I/O unavailability. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.259
cBladeCDROMIOAvailableTrapThe notification generated when cd-rom I/O becomes available on a cBlade. This trap is driven by 'Device IO Available Event' event types that describe cd-rom I/O availability. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.260
cBladeCDROMIOUnvailableTrapThe notification generated when cd-rom I/O becomes unavailable on a cBlade. This trap is driven by 'Device IO Unvailable Event' event types that describe cd-rom I/O unavailability. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.261
cBladeEthLinkUpTrapThe notification generated when a cBlade Eth Link Status is detected to be Up. This trap is driven by 'ethernet <ethname>@<framename>/c<1|2> Link Up Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.262
cBladeEthLinkDownTrapThe notification generated when a cBlade Eth Link Status is detected to be Down. This trap is driven by 'ethernet <ethname>@<framename>/c<1|2> Link Down Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.263
cBladeEthStatusActiveTrapThe notification generated when a cBlade Eth Reth Status is detected to be Active. This trap is driven by 'ethernet <ethname>@<framename>/c<1|2> Reth Status Active Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.264
cBladeEthStatusStandbyTrapThe notification generated when a cBlade Eth Reth Status is detected to be Standby. This trap is driven by 'ethernet <ethname>@<framename>/c<1|2> Reth Status Standby Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.265
cBladeEthStatusFailedTrapThe notification generated when a cBlade Eth Reth Status is detected to be Failed. This trap is driven by 'ethernet <ethname>@<framename>/c<1|2> Reth Status Failed Event' event type. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.266
cBladeEthStatusUnconfiguredTrapThe notification generated when a cBlade Eth Reth Status is detected to be Unconfigured (not part of a Reth). An Unconfigured cBlade Eth has Link Status Down. This trap is driven by 'ethernet <ethname>@<framename>/c<1|2> Reth Status Unconfigured Event' event type. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.267
cBladeHbaEnabledTrapThe notification generated when a cBlade HBA set to enabled. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.268
cBladeHbaDisabledTrapThe notification generated when a cBlade HBA set to disabled. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.269
cBladeHbaStatusDownTrapThe notification generated when a cBlade HBA status is down. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.270
cBladeHbaStatusChangedTrapThe notification generated when a cBlade HBA status is changed. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.271
sBladeInsertedTrapThe notification generated when an sBlade is inserted into a BladeFrame. This trap is driven by 'BladeFrame <framename> Blade Inserted Event' event types that describe sBlade insertions. Since the underlying event type describes pBlade, cBlade, and sBlade insertions, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeInsertedTrap and cBladeInsertedTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.301
sBladeRemovedTrapThe notification generated when an sBlade is removed from a BladeFrame. This trap is driven by 'BladeFrame <framename> Blade Removed Event' event types that describe sBlade removal events. Since the underlying event type describes pBlade, cBlade, and sBlade removal, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeRemovedTrap and cBladeRemovedTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.302
sBladePowerOnTrapThe notification generated when an sBlade is powered on. This trap is driven by 'Blade <framename>/s<1|2> Power Status Event' event types describing power on events. Since the underlying event type describes sBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladePowerOffTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. BladeFrame ES systems emit the cBladeSwitchCardOnTrap to indicate the switch card of the cBlade has been powered on. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.303
sBladePowerOffTrapThe notification generated when an sBlade is powered off. This trap is driven by 'Blade <framename>/s<1|2> Power Status Event' event types describing power on events. Since the underlying event type describes sBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladePowerOnTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. BladeFrame ES systems emit the cBladeSwitchCardOffTrap to indicate the switch card of the cBlade has been powered off. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.304
sBladeEnabledTrapThe notification generated when an sBlade is enabled (returns to service). This trap is driven by 'Blade <framename>/s<1|2> Out of Service Status false Event' event types. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.305
sBladeDisabledTrapThe notification generated when an SBlade is disabled. (removed from service). This trap is driven by 'Blade <framename>/s<1|2> Out of Service Status true Event' event types. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.306
sBladeSelectedTrapThe notification generated when an sBlade has been selected. This trap is driven by 'Blade <framename>/s<1|2> Selected Status true Event' even types. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.307
sBladeDeselectedTrapThe notification generated when a sBlade has been de-selected. This trap is driven by 'Blade <framename>/s<1|2> Selected Status false Event' even types. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.308
sBladeHwEventTrapEncapsulates generic events from hardware. This trap is driven by 'Blade <framename>/s<1|2> non-sensor Event' event types Examples message contents include: bmc reset Contact EES for more specific information. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.310
sBladeVoltageUpperTrapEncapsulates sBlade critical high voltage sensor events. This trap is driven by 'Blade <framename>/s<1|2> <voltage-sensor-name> Critical High Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.311
sBladeVoltageLowerTrapEncapsulates sBlade critical low voltage sensor events. This trap is driven by 'Blade <framename>/s<1|2> <voltage-sensor-name> Critical Low Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.312
sBladeFanSpeedUpperTrapEncapsulates sBlade critical high fan speed sensor events. This trap is driven by 'Blade <framename>/s<1|2> <fan-sensor-name> Critical High Event' event types. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.313
sBladeFanSpeedLowerTrapEncapsulates sBlade critical low fan speed sensor events. This trap is driven by 'Blade <framename>/s<1|2> <fan-sensor-name> Critical Low Event' event types. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.314
sBladeTempUpperTrapEncapsulates cBlade critical high temperature sensor events. This trap is driven by 'Blade <framename>/s<1|2> <temp-sensor-name> Critical High Event' event types. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.315
sBladeTempLowerTrapEncapsulates sBlade critical low temperature sensor events. This trap is driven by 'Blade <framename>/s<1|2> <temp-sensor-name> Critical Low Event' event types. This trap replaces sBladeHwThreshTrap. Since BladeFrame ES Systems do not utilize dedicated sBlades, this trap is not relevant to BladeFrame ES systems. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.316
sBladePowerOnOpTrapEncapsulates sBlade power on operation event. This trap is driven by 'sBlade <framename>/s<1|2> Hardware Operation Event' event types. Since the underlying event type describes sBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladePowerOffOpTrap, sBladePowerCycleTrap, and sBladeResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.317
sBladePowerOffOpTrapEncapsulates sBlade power off operation event. This trap is driven by 'sBlade <framename>/s<1|2> Hardware Operation Event' event types. Since the underlying event type describes sBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladePowerOnOpTrap, sBladePowerCycleTrap, and sBladeResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.318
sBladePowerCycleOpTrapEncapsulates sBlade power cycle operation event. This trap is driven by 'sBlade <framename>/s<1|2> Hardware Operation Event' event types. Since the underlying event type describes sBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladePowerOnOpTrap, sBladePowerCycleTrap, and sBladeResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.319
sBladeResetOpTrapEncapsulates sBlade reset operation event. This trap is driven by 'sBlade <framename>/s<1|2> Hardware Operation Event' event types. Since the underlying event type describes sBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladePowerOnOpTrap, sBladePowerCycleTrap, and sBladePowerCycleOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.320
sBladeNonFatalHwErrorTrapThe notification generated when sBlade hardware detects a non-fatal error. This trap is driven by 'sBlade <bladeframe>/s<1|2> NonFatal Hardware Error Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.321
sBladeFatalHwErrorTrapThe notification generated when sBlade hardware detects a fatal error. This trap is driven by 'sBlade <bladeframe>/s<1|2> Fatal Hardware Error Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.322
sBladeOutOfServicePendingTrapThe notification generated when a sBlade enters the 'out of service pending' state. This trap is driven by 'cBlade <bladeframe>/s<1|2> Out of Service Pending Event' event types Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.323
pBladeInsertedTrapThe notification generated when a pBlade is inserted into a BladeFrame. This trap is driven by 'BladeFrame <framename> Blade Inserted Event' event types that describe pBlade insertions. Since the underlying event type describes pBlade, sBlade, and sBlade insertions, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladeInsertedTrap and sBladeInsertedTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.401
pBladeRemovedTrapThe notification generated when a pBlade is removed from a BladeFrame. This trap is driven by 'BladeFrame <framename> Blade Removed Event' event types that describe pBlade removal events. Since the underlying event type describes pBlade, cBlade, and sBlade removal, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of sBladeRemovedTrap and cBladeRemovedTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.402
pBladePowerOnTrapThe notification generated when a pBlade is powered on. This trap is driven by 'Blade <framename>/p<1..24> Power Status Event' event types describing power on events. Since the underlying event type describes pBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePowerOffTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.403
pBladePowerOffTrapThe notification generated when a pBlade is powered off. This trap is driven by 'Blade <framename>/p<1..24> Power Status Event' event types describing power on events. Since the underlying event type describes sBlade power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePowerOnTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.404
pBladeBootedTrapThe notification generated when a pBlade has successfully booted. This trap is driven by 'blade.status.monitor.event' event types that describe a pBlade transition from the booting state to the running state. This event type is not user visible, and will not appear in CLI or GUI event queries. The trap exists to satisfy early requirements documents. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.405
pBladeShutdownTrapThe notification generated when a pBlade has been shut down. This trap is driven by 'blade.status.monitor.event' event types that describe a pBlade transition from the shutting down state to the shutdown state. This event type is not user visible, and will not appear in CLI or GUI event queries. The trap exists to satisfy early requirements documents. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.406
pBladeEnabledTrapThe notification generated when a pBlade has been enabled (returns to service). This trap is driven by 'Blade <framename>/p<1..24> Out of Service Status false Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.407
pBladeDisabledTrapThe notification generated when a pBlade has been disabled (removed from service). This trap is driven by 'Blade <framename>/p<1..24> Out of Service Status true Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.408
pBladeSelectedTrapThe notification generated when a pBlade has been selected. This trap is driven by 'Blade <framename>/p<1..24> Selected Status true Event' even types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.409
pBladeDeselectedTrapThe notification generated when a pBlade has been unselected. This trap is driven by 'Blade <framename>/p<1..24> Selected Status false Event' even types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.410
pBladeHwEventTrapEncapsulates generic events from hardware. This trap is driven by 'Blade <framename>/p<1..24> non-sensor Event' event types that do not indicate panic, commanded shutdown, commanded reboot, or init level events. Examples message contents include: OEM Type 0xe0, value = 0x64:0x21:0xce:0xe0:0x1d:0x00:0x00:0x00... bmc reset deasserted, value = 0x0211 system booted Contact EES for more specific information. Since the underlying event type describes pBlade all non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePanicTrap, pBladeCmdShutdownTrap, pBladeCmdRebootTrap, pBladeCmdHaltTrap, and pBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.411
pBladePanicTrapEncapsulates hardware events identifying pBlade panics that cause the cBlade to enter KDB, reboot, or halt' This trap is driven by 'Blade <framename>/p<1..24> non-sensor Event' event types that describe kernel panics. Contact EES for more specific information. Since the underlying event type describes pBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeHwEventTrap, pBladeCmdShutdownTrap, pBladeCmdRebootTrap, pBladeCmdHaltTrap, and pBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.413
pBladeCmdHaltTrapEncapsulates hardware events indicating intentional pBlade halt. This trap is driven by 'Blade <framename>/p<1..24> non-sensor Event' event types that describe commanded halts. Contact EES for more specific information. Since the underlying event type describes pBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeHwEventTrap, pBladeCmdShutdownTrap, pBladeCmdRebootTrap, pBladePanicTrap, and pBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.414
pBladeCmdRebootTrapEncapsulates hardware events indicating intentional pBlade reboot. This trap is driven by 'Blade <framename>/p<1..24> non-sensor Event' event types that describe commanded reboots. Contact EES for more specific information. Since the underlying event type describes pBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeHwEventTrap, pBladeCmdShutdownTrap, pBladeCmdHaltTrap, pBladePanicTrap, and pBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.415
pBladeInitTrapEncapsulates hardware events indicating intentional pBlade has reached an init level. This trap is driven by 'Blade <framename>/p<1..24> non-sensor Event' event types that describe init level reached. Contact EES for more specific information. Since the underlying event type describes pBlade non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladeHwEventTrap, pBladeCmdShutdownTrap, pBladeCmdHaltTrap, pBladeCmdRebootTrap, and pBladePanicTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.416
pBladeVoltageUpperTrapEncapsulates pBlade critical high voltage sensor events. This trap is driven by 'Blade <framename>/p<1..24> <voltage-sensor-name> Critical High Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces pBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.417
pBladeVoltageLowerTrapEncapsulates pBlade critical low voltage sensor events. This trap is driven by 'Blade <framename>/p<1..24> <voltage-sensor-name> Critical Low Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces pBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.418
pBladeFanSpeedUpperTrapEncapsulates pBlade critical high fan speed sensor events. This trap is driven by 'Blade <framename>/p<1..24> <fan-sensor-name> Critical High Event' event types. This trap replaces pBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.419
pBladeFanSpeedLowerTrapEncapsulates pBlade critical low fan speed sensor events. This trap is driven by 'Blade <framename>/p<1..24> <fan-sensor-name> Critical Low Event' event types. This trap replaces pBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.420
pBladeTempUpperTrapEncapsulates pBlade critical high temperature sensor events. This trap is driven by 'Blade <framename>/p<1..24> <temp-sensor-name> Critical High Event' event types. This trap replaces pBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.421
pBladeTempLowerTrapEncapsulates pBlade critical low temperature sensor events. This trap is driven by 'Blade <framename>/p<1..24> <temp-sensor-name> Critical Low Event' event types. This trap replaces pBladeHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.422
pBladeWinkoutTrapEncapsulates pBlade wink-out events.. This trap is driven by 'pBlade <framename>/p<1..24> Winked Out Event event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.423
pBladePowerOnOpTrapEncapsulates pBlade power on operation event. This trap is driven by 'pBlade <framename>/p<1..24> Hardware Operation Event' event types. Since the underlying event type describes pBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePowerOffOpTrap, pBladePowerCycleTrap, pBladeResetOpTrap, and pBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.424
pBladePowerOffOpTrapEncapsulates pBlade power off operation event. This trap is driven by 'pBlade <framename>/p<1..24> Hardware Operation Event' event types. Since the underlying event type describes pBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePowerOnOpTrap, pBladePowerCycleTrap, pBladeResetOpTrap, and pBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.425
pBladePowerCycleOpTrapEncapsulates pBlade power cycle operation event. This trap is driven by 'pBlade <framename>/p<1..24> Hardware Operation Event' event types. Since the underlying event type describes pBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePowerOnOpTrap, pBladePowerCycleTrap, pBladeResetOpTrap, and pBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.426
pBladeResetOpTrapEncapsulates pBlade reset operation event. This trap is driven by 'pBlade <framename>/p<1..24> Hardware Operation Event' event types. Since the underlying event type describes pBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePowerOnOpTrap, pBladePowerCycleTrap, pBladePowerCycleOpTrap, and pBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.427
pBladeNMIOpTrapEncapsulates pBlade reset operation event. This trap is driven by 'pBlade <framename>/p<1..24> Hardware Operation Event' event types. Since the underlying event type describes pBlade power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pBladePowerOnOpTrap, pBladePowerCycleTrap, pBladePowerCycleOpTrap, and pBladeResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.428
pBladeNonFatalHwErrorTrapThe notification generated when pBlade hardware detects a non-fatal error, such as a correctable ECC memory error. This trap is driven by 'pBlade <bladeframe>/p<1..24> NonFatal Hardware Error Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.429
pBladeFatalHwErrorTrapThe notification generated when pBlade hardware detects a fatal error, such as an uncorrectable ECC memory error. This trap is driven by 'pBlade <bladeframe>/p<1..24> Fatal Hardware Error Event' event types. Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.430
pBladeHwErrorThresholdTrapThe notification generated when pBlade is shutdown and marked out-of-service due to excessive fatal hardware errors This trap is driven by 'pBlade <bladeframe>/p<1..24> Hardware Error Threshold Event' event types Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.431
pBladeOutOfServicePendingTrapThe notification generated when a pBlade enters the 'out of service pending' state. This trap is driven by 'cBlade <bladeframe>/p<1..24> Out of Service Pending Event' event types Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.432
pBladeBootImageChangedTrapThe notification generated when a pBlade boot image is changed. This trap is driven by 'pBlade <bladeframe>/p<1..24> Boot Image Changed Event' event types Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.433
pBladeVbladeRamOvercommitTrapThe notification generated when vBlade RAM is overcommited on pBlade insert. This trap is driven by 'pBlade <bladeframe>/p<1..24> vBlade RAM Overcommit Event' event types Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.434
pBladeIpmiCeccThresholdTrapThe notification generated when a pBlade has met the Correctable ECC Event Threshold. This trap is driven by 'pBlade <bladeframe>/p<1..24> Ipmi Cecc Threshold Event' event types Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.435
pBladeWarmedTrapThe notification generated when a pBlade is set to the warm state. This trap is driven by 'pBlade <framename>/p<1..24> Warmed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.438
lPanCreatedTrapThe notification generated when an LPAN is created. This trap is driven by 'LPAN <lpanname> create event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.501
lPanDeletedTrapThe notification generated when an LPAN is deleted. This trap is driven by 'LPAN <lpanname> delete event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.502
lPanBootedTrapThe notification generated when an LPAN is booted. This trap is driven by 'LPAN <lpanname> boot event' event types. This trap is deprecate as of 4.0.0. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.503
lPanShutdownTrapThe notification generated when an LPAN is shutdown. This trap is driven by 'LPAN <lpanname> shutdown event' event types. This trap is deprecate as of 4.0.0. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.504
lPanResourceUnavailableTrapThe notification generated when a resource required by the LPAN is unavailable. This trap is driven by 'LPAN <lpanname> resource unavailable event' This trap is deprecate as of 4.0.0. event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.505
lPanModifyTrapThe notification generated when when a logical PAN is modified. This trap is driven by 'LPAN <lpanname> Configuration Change Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.506
lPanActivatedTrapThe notification generated when when an LPAN is activated. This trap is driven by 'LPAN <lpanname> Activated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.507
lPanDeactivatedTrapThe notification generated when when an LPAN is deactivated. This trap is driven by 'LPAN <lpanname> Deactivated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.508
lPanDeviceAvailableTrapThe notification generated when when a device becomes available to an LPAN. This trap is driven by 'LPAN <lpanname> Device Available Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.509
lPanDeviceUnavailableTrapThe notification generated when when a device becomes unavailable to an LPAN. This trap is driven by 'LPAN <lpanname> Device Unavailable Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.510
lPanPBladeAvailableTrapThe notification generated when when a pBlade becomes available to an LPAN. This trap is driven by 'LPAN <lpanname> pBlade Available Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.511
lPanPBladeUnavailableTrapThe notification generated when when a pBlade becomes unavailable to an LPAN. This trap is driven by 'LPAN <lpanname> pBlade Unavailable Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.512
lPanPBladeAllocatedTrapThe notification generated when when a pBlade is allocated to an LPAN. This trap is driven by 'pBlade <framename>/p<1..24> Allocated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.513
lPanPBladeDeallocatedTrapThe notification generated when when a pBlade is deallocated from an LPAN. This trap is driven by 'pBlade <framename>/p<1..24> Deallocated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.514
lPanUserMonitorCreatedTrapThe notification generated when when a User Defined Monitor is created in an LPAN. This trap is driven by 'LPAN <lpanname> User Monitor Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.515
lPanUserMonitorModifiedTrapThe notification generated when when a User Defined Monitor is modified in an LPAN. This trap is driven by 'LPAN <lpanname> User Monitor Modified Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.516
lPanUserMonitorDeletedTrapThe notification generated when when a User Defined Monitor is deleted in an LPAN. This trap is driven by 'LPAN <lpanname> User Monitor Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.517
lPanOperationStartedTrapThe notification generated when LPAN operation is initiated. This trap is driven by 'LPAN <lpanname> Operation Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.518
lPanOperationCompletedTrapThe notification generated when LPAN operation completes. This trap is driven by 'LPAN <lpanname> Operation Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.519
lPanOperationAbortedTrapThe notification generated when LPAN operation is aborted. This trap is driven by 'LPAN <lpanname> Operation Aborted Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.520
pServerBootedTrapThe notification generated when a pServer is booted. This trap is driven by 'pServer <lpanname>/<pservername> boot event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.601
pServerShutdownTrapThe notification generated when a pServer is shutdown. This trap is driven by 'pServer <lpanname>/<pservername> shutdown event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.602
pServerBootFailedTrapThe notification generated when a pServer fails to boot. This trap is driven by 'pServer <lpanname>/<pservername> Boot Failed Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.603
pServerSyslogEventTrapThe notification sent when a syslog target string is emmited from the system logger. This trap is driven by 'pServer <lpanname>/<pservername> Custom Linux System Message <1..10>' event types. See 'eventtype -l' for more information. There are 10 pServer syslog event types. This trap can be enabled/disabled for each syslog event type independently. Severity: (configurable by EES, generally 1, 2 or 3)
TRAP-TYPE
.1.3.6.1.4.1.7559.0.604
pServerDebuggerEnterTrapThe notification generated when the debbugger has been invoked on the pServer. This trap is driven by 'blade.status.monitor.event' event types that describe a pBlade transition to the 'in kdb' state. This event type is not user visible, and will not appear in CLI or GUI event queries. The trap exists to satisfy early requirements documents. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.605
pServerDebuggerExitTrapThe notification generated when the debbugger has been exited on the pServer. This trap is driven by 'blade.status.monitor.event' event types that describe a pBlade transition from the 'in kdb' state. This event type is not user visible, and will not appear in CLI or GUI event queries. The trap exists to satisfy early requirements documents. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.606
pServerResourceUnavailableTrapThis trap is deprecated as of PAN Manager release 4.0.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.607
pServerSystemThresholdHighTrapThe notification generated when a pServer system monitor has exceeded its high threshold, or returns below the high threshold. This trap is driven by 'pServer <lpanname>/<pservername> <monitorname> event' event types. Note that a severity 3 event is emmitted when the threshold is crossed in the rising direction, while a severity 5 event is emmitted when the monitored value returns below the threshold. Thus it is possible to recieve a severity 5 pServerSystemThresholdHighTrap with a message like: pcw/p2 pServer pcw/p2 5 Minute Load Average returned below 10.0 on average for 300 seconds, Current value = 4.79 Severity: 3/5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.608
pServerSystemThresholdlowTrapThe notification generated when a pServer system monitor has exceeded its low threshold, or returns above the low threshold. Currently, no software values are monitored for critically low values, and this trap is not emitted. Because there is no driving event type, there is no severity.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.609
pServerFailedTrapThe notification generated when a booted pServer fails. This trap is driven by 'pServer <lpanname>/<pservername> failed event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.610
pServerRecoverTrapThe notification generated when a failed pServer has been successfully recovered, generally due to pBlade failover. This trap is driven by 'pServer <lpanname>/<pservername> recover event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.611
pServerBootingTrapThe notification generated when a pServer begins the process of booting. This trap is driven by 'pServer <lpanname>/<pservername> Booting Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.612
pServerCreatedTrapThe notification generated when a pServer is created. This trap is driven by 'pServer <lpanname>/<pservername> create event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.613
pServerDeletedTrapThe notification generated when a pServer is deleted. This trap is driven by 'pServer <lpanname>/<pservername> delete event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.614
pServerFailoverTrapThe notification generated when a pServer begins the process of failing over. This trap is driven by 'pServer <lpanname>/<pservername> Failover attempted Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.615
pServerModifiedTrapThe notification generated when a pServer configuration is modified. This trap is driven by 'pServer <lpanname>/<pservername> Configuration Change Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.616
pServerRebootingTrapThe notification generated when a pServer reboot has initiated. This trap is driven by 'pServer decker/ps1 Rebooting Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.617
pServerShuttingDownTrapThe notification generated when a pServer shutdown has initiated. This trap is driven by 'pServer <lpanname>/<pservername> Shutting Down Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.618
pServerAgentArrivedTrapThe notification generated when a pServer agent has arrived. This trap is driven by 'pServer <lpanname>/<pservername> Agent Available Event' event types Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.619
pServerAgentDepartedTrapThe notification generated when a pServer agent has departed. This trap is driven by 'pServer <lpanname>/<pservername> PAN Agent Unavailable Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.620
pServerSyslogDroppedTrapThe notification sent when a syslog target string message is dropped due to rate limiting. This trap is driven by 'pServer <lpanname>/<pservername> Custom Linux System Messages dropped' event types. System message events are subject to rate limiting. By default, no more than 5 messages can be emitted during a 5 minute period. If more than 5 target strings are encountered, events will only be created for the first 5 messages, subsequent messages will be dropped. At the end of the 5 minute period, a 'Messages Dropped' event will be emmitted to indicate the number of dropped messages during the 5 minute period. Contact EES for more information. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.621
pServerSyslogPollingStoppedTrapThe notification sent when a syslog polling has stopped due to rate limiting. This trap is driven by the 'pServer <lpanname>/<pservername> Custom Linux System Messages polling stopped' event type. System message events are subject to rate limiting. By default, no more than 5 messages can be emitted during a 5 minute period. If more than 5 target strings are encountered, events will only be created for the first 5 messages, subsequent messages will be dropped. If messages are dropped for 5 consecutive 5 minute periods, syslog message polling will be disabled on that cBlade. Contact EES for more information. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.622
pServerShutdownFailedTrapThe notification sent when a pServer shutdown fails. This trap is driven by the 'pServer <lpanname>/<pservername> Shutdown Failed Event' event type. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.623
pServerPBladeAllocatedTrapThe notification generated when when a pBlade is allocated to a pServer. This trap is driven by 'pBlade <framename>/p<1..24> Allocated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.624
pServerPBladeDeallocatedTrapThe notification generated when when a pBlade is deallocated from a pServer. This trap is driven by 'pBlade <framename>/p<1..24> Deallocated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.625
pServerPanicCycleTrapThe notification generated when when a pServer panic cycle is detected. This trap is driven by 'pServer <lpanname>/<pservername> Panic Cycle Event' Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.626
pServerUserMonitorTrapThe notification generated when a user defined monitor rule is matched. This trap is driven by 'pServer <lpanname>/<pservername> User Monitor Event: <lpanname>/<pservername>/<monitorname> Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.627
pServerHardwareOnlineTrapThe notification generated when hardware for a pServer agent goes online. This trap is driven by 'pServer <lpanname>/<pservername> Hardware Online Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.628
pServerHardwareOfflineTrapThe notification generated when hardware for a pServer agent goes offline. This trap is driven by 'pServer <lpanname>/<pservername> Hardware Offline Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.629
pServerRecoveredTrapThe notification generated when pServer recovers from a failure. This trap is driven by 'pServer <lpanname>/<pservername> Recovered Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.630
pServerDiskAvailableTrapThe notification generated when a disk on a pServer becomes available. This trap is driven by 'pServer <lpanname>/<pservername> Disk Available Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.631
pServerDiskUnavailableTrapThe notification generated when a disk on a pServer is unavailable at boot time. This trap is driven by 'pServer <lpanname>/<pservername> Disk Unavailable Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.632
pServerOperationStartedTrapThe notification generated when a pServer operation has been invoked. This trap is driven by 'pServer <lpanname>/<pservername> Operation Started' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.633
pServerPBladeAvailableTrapThe notification generated when a pServer pBlade becomes available. This trap is driven by 'pServer <lpanname>/<pservername> pBlade Available Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.634
pServerMigratingTrapThe notification generated when a pServer starts to migrate. This trap is driven by 'pServer <lpanname>/<pservername> Migrating Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.635
pServerMigratedTrapThe notification generated when a pServer is migrated. This trap is driven by 'pServer <lpanname>/<pservername> Migrate Succeeded Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.636
pServerMigrateFailedTrapThe notification generated when a pServer fails to migrate. This trap is driven by 'pServer <lpanname>/<pservername> Migrate Failed Event' event types.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.637
pServerSuspendingTrapThe notification generated when a pServer starts to suspend. This trap is driven by 'pServer <lpanname>/<pservername> Suspending Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.638
pServerSuspendedTrapThe notification generated when a pServer suspend is completed. This trap is driven by 'pServer <lpanname>/<pservername> Suspend Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.639
pServerSuspendFailedTrapThe notification generated when a pServer fails to suspend. This trap is driven by 'pServer <lpanname>/<pservername> Suspend Failed Event' event types.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.640
pServerResumingTrapThe notification generated when a pServer starts to resume. This trap is driven by 'pServer <lpanname>/<pservername> Resume Started Event' event types.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.641
pServerResumedTrapThe notification generated when a pServer resume is completed. This trap is driven by 'pServer <lpanname>/<pservername> Resume Completed Event' event types.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.642
pServerResumeFailedTrapThe notification generated when a pServer fails to resume. This trap is driven by 'pServer <lpanname>/<pservername> Resume Failed Event' event types.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.643
pServerUserMonitorFailedTrapThe notification generated when a user defined monitor is failed. This trap is driven by 'pServer <lpanname>/<pservername> User Monitor Failed Event: <lpanname>/<pservername>/<monitorname> Severity: 1
TRAP-TYPE
.1.3.6.1.4.1.7559.0.644
pServerVBladeAllocatedTrapThe notification generated when when a vBlade is allocated to a pServer. This trap is driven by 'vBlade <framename>/p<1..24-1..n> Allocated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.645
pServerVBladeDeallocatedTrapThe notification generated when when a pBlade is deallocated from a pServer. This trap is driven by 'vBlade <framename>/p<1..24-1..n> Deallocated Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.646
pServerAgentGetDataFailedTrapThe notification generated when a pServer agent does not return requests for statistical data. This trap is driven by 'pServer <lpanname>/<pservername> PAN Agent ' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.647
failoverPoolExaustedTrapThe notification generated when a failover blade pool is exhausted. This trap is deprecated because there is no underlying event to drive the trap. The trap definition exists to satisfy early requirements documents.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.701
applicationStartedTrapThe notification generated when an application has started successfully. This trap is driven by 'application <lpanname>/<appname> Start Completed Event ' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.801
applicationStoppedTrapThe notification generated when an application has been successfully stopped. This trap is driven by 'application <lpanname>/<appname> Stop Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.802
applicationRestartedTrapThe notification generated when an application failures have been detected by the health monitor, and the 'restart' threshold has been reached or exceeded. This results in an attempt to restart the application, for which further traps will be generated: applicationStartingTrap applicationStartedTrap applicationStartFailedTrap This trap is driven by 'application <lpanname>/<appname> Health Monitor Restart Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.803
applicationFailoverTrapThe notification generated when an application failures have been detected by the health monitor, and the 'failover' threshold has been reached or exceeded. This results in an attempt to failover the application, for which further traps will be generated: applicationMovingTrap applicationMovedTrap applicationMoveFailedTrap This trap is driven by 'application <lpanname>/<appname> Health Monitor Failover Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.804
applicationGiveupTrapThe notification generated when an application failures have been detected by the health monitor, and the 'giveup' threshold has been reached or exceeded. This results in the PAN Manager stop, for which further traps will be generated: applicationStoppingTrap applicationStoppedTrap applicationStopFailed This trap is driven by 'application <lpanname>/<appname> Health Monitor GiveUp Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.805
applicationFailedTrapThis trap is deprecated as of PAN Manager release 4.0. See the following more specific traps: applicationStartFailedTrap applicationStopFailed applicationMoveFailedTrap applicationRestartedTrap applicationFailoverTrap applicationGiveupTrap
TRAP-TYPE
.1.3.6.1.4.1.7559.0.809
applicationMonitorFailedTrapThe notification generated when an application monitor failed, generally due to a missing PAN Agent. This trap is driven by 'application <lpanname>/<appname> Health Monitor Failed Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.814
applicationMonitorRecoveredTrapThe notification generated when an application monitor recovers, generally due to a restored PAN Agent. This trap is driven by 'application <lpanname>/<appname> Health Monitor Recovered Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.815
applicationMonitorInvalidTrapThe notification generated when an application monitor is, discovered to be invalid, generally due to misconfiguration. This trap is driven by 'application <lpanname>/<appname> Health Monitor Invalid Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.816
applicationCreatedTrapThe notification generated when an application has been created. This trap is driven by 'LPAN <lpanname> application Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.817
applicationModifyTrapThe notification generated when an application is modified. This trap is driven by 'application <lpanname>/<appname> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.818
applicationDeletedTrapThe notification generated when an application has been deleted. This trap is driven by 'LPAN <lpanname> application Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.819
applicationStartingTrapThe notification generated when an application start has been initiated. This trap is driven by 'application <lpanname>/<appname> Start Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.820
applicationStartFailedTrapThe notification generated when an application start attempt has failed. This trap is driven by 'application <lpanname>/<appname> Start Failed Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.821
applicationStoppingTrapThe notification generated when an application stop has been initiated. This trap is driven by 'application <lpanname>/<appname> Stop Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.822
applicationStopFailedTrapThe notification generated when an application has failed to stop. This trap is driven by 'application <lpanname>/<appname> Stop Failed Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.823
applicationMovingTrapThe notification generated when an application move has been initiated. This trap is driven by 'application <lpanname>/<appname> Move Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.824
applicationMovedTrapThe notification generated when an application move has successfully completed. This trap is driven by 'application <lpanname>/<appname> Move Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.825
applicationMoveFailedTrapThe notification generated when an application move has failed. This trap is driven by 'application <lpanname>/<appname> Move Failed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.826
applicationFailingOverTrapThe notification generated when an application failover has been initiated. This trap is driven by 'application <lpanname>/<appname> Failover Started Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.827
applicationFailedOverTrapThe notification generated when an application failover has successfully completed. This trap is driven by 'application <lpanname>/<appname> Failover Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.828
applicationFailoverFailedTrapThe notification generated when an application failover has failed. This trap is driven by 'application <lpanname>/<appname> Failover Failed Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.829
applicationFailureDetectedTrapThe notification generated when an application health monitor has detected an application failure. These failures are counted, and compared to 'restart after', 'failover after', and 'giveup after' thresholds of the health monitor to trigger application actions. This trap is driven by 'application <lpanname>/<appname> Health Monitor Detected Failure Event' event types. Severity: 4
TRAP-TYPE
.1.3.6.1.4.1.7559.0.830
applicationConfigWarningTrapThe notification generated when an application is potentially misconfigured. This trap is driven by 'application <lpanname>/<appname> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.831
applicationStatusWarningTrapThe notification generated when an application operation results in a potentially inappropriate state. This trap is driven by 'application <lpanname>/<appname> Status Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.832
loadBalancerCreatedTrapThe notification generated when a load balancer has been created. This trap is driven by 'LPAN <lpanname> load balancer Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.840
loadBalancerModifyTrapThe notification generated when a load balancer is modified. This trap is driven by 'load balancer <lpanname>/<lbname> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.841
loadBalancerDeletedTrapThe notification generated when a load balancer has been deleted. This trap is driven by 'LPAN <lpanname> load balancer Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.842
loadBalancerStartingTrapThe notification generated when a load balancer start has been initiated. This trap is driven by 'load balancer <lpanname>/<lbname> Start Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.843
loadBalancerStartedTrapThe notification generated when a load balancer has started successfully. This trap is driven by 'load balancer <lpanname>/<lbname> Start Completed Event ' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.844
loadBalancerStartFailedTrapThe notification generated when a load balancer start attempt has failed. This trap is driven by 'load balancer <lpanname>/<lbname> Start Failed Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.845
loadBalancerStoppingTrapThe notification generated when a load balancer stop has been initiated. This trap is driven by 'load balancer <lpanname>/<lbname> Stop Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.846
loadBalancerStoppedTrapThe notification generated when a load balancer has been successfully stopped. This trap is driven by 'load balancer <lpanname>/<lbname> Stop Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.847
loadBalancerStopFailedTrapThe notification generated when a load balancer has failed to stop. This trap is driven by 'load balancer <lpanname>/<lbname> Stop Failed Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.848
loadBalancerMovingTrapThe notification generated when a load balancer move has been initiated. This trap is driven by 'load balancer <lpanname>/<lbname> Move Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.849
loadBalancerMovedTrapThe notification generated when a load balancer move has successfully completed. This trap is driven by 'load balancer <lpanname>/<lbname> Move Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.850
loadBalancerMoveFailedTrapThe notification generated when a load balancer move has failed. This trap is driven by 'load balancer <lpanname>/<lbname> Move Failed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.851
loadBalancerFailingOverTrapThe notification generated when a load balancer failover has been initiated. This trap is driven by 'load balancer <lpanname>/<lbname> Failover Started Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.852
loadBalancerFailedOverTrapThe notification generated when a load balancer failover has successfully completed. This trap is driven by 'load balancer <lpanname>/<lbname> Failover Completed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.853
loadBalancerFailoverFailedTrapThe notification generated when a load balancer failover has failed. This trap is driven by 'load balancer <lpanname>/<lbname> Failover Failed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.854
loadBalancerRestartedTrapThe notification generated when a load balancer failures have been detected by the health monitor, and the 'restart' threshold has been reached or exceeded. This results in an attempt to restart the load balancer, for which further traps will be generated: loadBalancerStartingTrap loadBalancerStartedTrap loadBalancerStartFailedTrap This trap is driven by 'load balancer <lpanname>/<lbname> Health Monitor Restart Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.855
loadBalancerFailoverTrapThe notification generated when a load balancer failures have been detected by the health monitor, and the 'failover' threshold has been reached or exceeded. This results in an attempt to failover the load balancer, for which further traps will be generated: loadBalancerMovingTrap loadBalancerMovedTrap loadBalancerMoveFailedTrap This trap is driven by 'load balancer <lpanname>/<lbname> Health Monitor Failover Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.856
loadBalancerGiveupTrapThe notification generated when a load balancer failures have been detected by the health monitor, and the 'giveup' threshold has been reached or exceeded. This results in the PAN Manager stop, for which further traps will be generated: loadBalancerStoppingTrap loadBalancerStoppedTrap loadBalancerStopFailed This trap is driven by 'load balancer <lpanname>/<lbname> Health Monitor GiveUp Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.857
loadBalancerMonitorFailedTrapThe notification generated when a load balancer monitor failed, generally due to a missing PAN Agent. This trap is driven by 'load balancer <lpanname>/<lbname> Health Monitor Failed Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.858
loadBalancerMonitorRecoveredTrapThe notification generated when a load balancer monitor recovers, generally due to a restored PAN Agent. This trap is driven by 'load balancer <lpanname>/<lbname> Health Monitor Recovered Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.859
loadBalancerMonitorInvalidTrapThe notification generated when a load balancer monitor is, discovered to be invalid, generally due to misconfiguration. This trap is driven by 'load balancer <lpanname>/<lbname> Health Monitor Invalid Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.860
loadBalancerFailureDetectedTrapThe notification generated when a load balancer health monitor has detected a load balancer failure. These failures are counted, and compared to 'restart after', 'failover after', and 'giveup after' thresholds of the health monitor to trigger load balancer actions. This trap is driven by 'load balancer <lpanname>/<lbname> Health Monitor Detected Failure Event' event types. Severity: 4
TRAP-TYPE
.1.3.6.1.4.1.7559.0.861
loadBalancerConfigWarningTrapThe notification generated when a load balancer is potentially misconfigured. This trap is driven by 'application <lpanname>/<appname> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.862
loadBalancerStatusWarningTrapThe notification generated when an application operation results in a potentially inappropriate state. This trap is driven by 'application <lpanname>/<appname> Status Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.863
nfsResourceCreateTrapThe notification generated when an nfs resource is created. This trap is driven by 'LPAN <lpanname> NFS resource Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.871
nfsResourceModifyTrapThe notification generated when an nfs resource is created. This trap is driven by 'NFS resource <resourcename> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.872
nfsResourceDeleteTrapThe notification generated when an nfs resource is deleted. This trap is driven by 'LPAN <lpanname> NFS resource Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.873
scsiDiskResourceCreateTrapThe notification generated when a scsi disk resource is created. This trap is driven by 'LPAN <lpanname> SCSI disk resource Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.874
scsiDiskResourceModifyTrapThe notification generated when a scsi disk resource is modified. This trap is driven by 'SCSI disk resource <resourcename> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.875
scsiDiskResourceDeleteTrapThe notification generated when a scsi disk resource is deleted. This trap is driven by 'LPAN <lpanname> SCSI disk resource Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.876
networkResourceCreateTrapThe notification generated when a network resource is created. This trap is driven by 'LPAN <lpanname> network resource Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.877
networkResourceModifyTrapThe notification generated when a network resource is created. This trap is driven by 'network resource <resourcename> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.878
networkResourceDeleteTrapThe notification generated when a network resource is deleted. This trap is driven by 'LPAN <lpanname> network resource Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.879
failoverPolicyCreateTrapThe notification generated when a failover policy is created. This trap is driven by 'LPAN <lpanname> failover policy Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.880
failoverPolicyModifyTrapThe notification generated when a failover policy is created. This trap is driven by 'failover policy <resourcename> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.881
failoverPolicyDeleteTrapThe notification generated when a failover policy is deleted. This trap is driven by 'LPAN <lpanname> failover policy Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.882
executableResourceCreateTrapThe notification generated when an executable resource is created. This trap is driven by 'LPAN <lpanname> executable resource Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.883
executableResourceModifyTrapThe notification generated when an executable resource is modified. This trap is driven by 'executable resource <resourcename> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.884
executableResourceDeleteTrapThe notification generated when an executable resource is deleted. This trap is driven by 'LPAN <lpanname> executable resource Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.885
healthMonitorCreateTrapThe notification generated when an health monitor is created. This trap is driven by 'LPAN <lpanname> health monitor Create Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.886
healthMonitorModifyTrapThe notification generated when an health monitor is created. This trap is driven by 'health monitor <resourcename> Changed Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.887
healthMonitorDeleteTrapThe notification generated when an health monitor is deleted. This trap is driven by 'LPAN <lpanname> health monitor Delete Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.888
nfsResourceConfigWarningTrapThe notification generated when an nfs resource is potentially misconfigured. This trap is driven by 'NFS resource <resourcename> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.889
scsiDiskResourceConfigWarningTrapThe notification generated when a scsi disk resource is potentially misconfigured. This trap is driven by 'SCSI disk resource <resourcename> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.890
networkResourceConfigWarningTrapThe notification generated when a network resource is potentially misconfigured. This trap is driven by 'network resource <resourcename> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.891
failoverPolicyConfigWarningTrapThe notification generated when a failover policy is potentially misconfigured. This trap is driven by 'failover policy <resourcename> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.892
executableResourceConfigWarningTrapThe notification generated when an executable resource is potentially misconfigured. This trap is driven by 'executable resource <resourcename> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.893
healthMonitorConfigWarningTrapThe notification generated when a health monitor is potentially misconfigured. This trap is driven by 'health monitor <resourcename> Configuration Warning Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.894
userCreatedTrapThe notification generated when a user has been created. This trap is driven by 'User Added Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.901
userDeletedTrapThe notification generated when a user has been deleted. This trap is driven by 'User Deleted Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.902
userLoginTrapThe notification generated when a user has logged in to the PAN Manager. This trap is deprecated, as there is no underlying even to drive the trap. The definition exists to satisfy early requirements documents.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.903
userLogoutTrapThe notification generated when a user has logged out of the PAN Manager. This trap is deprecated, as there is no underlying even to drive the trap. The definition exists to satisfy early requirements documents.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.904
userModifiedTrapThe notification generated when a user has been modified. This trap is driven by 'User Modified Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.905
invalidManagerRequestTrapThe notification generated when an unauthorized SNMP manager sends a request to the agent. This event is driven by incoming SNMP packets, and currently is not logged.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1001
invalidCommStringRequestTrapThe notification generated when an authorized SNMP manager sends a request containing an invalid community string. This event is driven by incoming SNMP packets, and currently is not logged.
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1002
pimSelectedTrapThe notification generated when a pim has been selected. This trap is driven by 'PIM <framename>/pim<1..4> Selected Status false Event' even types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1101
pimDeselectedTrapThe notification generated when a pim has been unselected. This trap is driven by 'PIM <framename>/pim<1..4> Selected Status false Event' even types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1102
pimPowerThresholdHighTrapThe notification generated when a pim's power threshold is high. This trap is driven by 'PIM <framename>/pim<1..4> Power Threshold High' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1103
pimCurrentThresholdHighTrapThe notification generated when a pim's current threshold is high. This trap is driven by 'PIM <framename>/pim<1..4> Current Threshold High' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1104
pimSourceTransitionTrapThe notification generated when a pim's source transition happened. This trap is driven by 'PIM <framename>/pim<1..4> Source Transition' event types. Severity: 4
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1105
pimInsertedTrapThe notification generated when a pim is inserted. This trap is driven by 'PIM <framename>/pim<1..4> Inserted' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1106
pimRemovedTrapThe notification generated when a pim is ejected. This trap is driven by 'PIM <framename>/pim<1..4> Removed' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1107
pimSourcePreferenceConfiguredTrapThe notification generated when a pim source preference is configured. This trap is driven by 'PIM <framename>/pim<1..4> Source Preference Configured' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1108
pimConfigErrorTrapThe notification generated when a pim encounters an error activating a configuration changea. This trap is driven by 'PIM <framename>/pim<1..4> Config Error Event' event types. Severity: 2
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1109
pimPowerOnTrapThe notification generated when an pim is powered on. This trap is driven by 'Blade <framename>/pim<1..4> Power Status Event' event types describing power on events. Since the underlying event type describes pim power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pimPowerOffTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1110
pimPowerOffTrapThe notification generated when an pim is powered off. This trap is driven by 'Blade <framename>/pim<1..4> Power Status Event' event types describing power on events. Since the underlying event type describes pim power on and off events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pimPowerOnTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1111
pimEnabledTrapThe notification generated when an pim is enabled (returns to service). This trap is driven by 'Blade <framename>/pim<1..4> Out of Service Status false Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1112
pimDisabledTrapThe notification generated when an pim is disabled. (removed from service). This trap is driven by 'Blade <framename>/pim<1..4> Out of Service Status true Event' event types. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1113
pimOutOfServicePendingTrapThe notification generated when a pBlade enters the 'out of service pending' state. This trap is driven by 'cBlade <bladeframe>/pim<1..4> Out of Service Pending Event' event types Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1114
pimPowerOnOpTrapEncapsulates pim power on operation event. This trap is driven by 'pim <framename>/pim<1..4> Hardware Operation Event' event types. Since the underlying event type describes pim power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pimPowerOffOpTrap, pimPowerCycleTrap, and pimResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1115
pimPowerOffOpTrapEncapsulates pim power off operation event. This trap is driven by 'pim <framename>/pim<1..4> Hardware Operation Event' event types. Since the underlying event type describes pim power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pimPowerOnOpTrap, pimPowerCycleTrap, and pimResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1116
pimPowerCycleOpTrapEncapsulates pim power cycle operation event. This trap is driven by 'pim <framename>/pim<1..4> Hardware Operation Event' event types. Since the underlying event type describes pim power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pimPowerOnOpTrap, pimPowerCycleTrap, and pimResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1117
pimResetOpTrapEncapsulates pim reset operation event. This trap is driven by 'pim <framename>/pim<1..4> Hardware Operation Event' event types. Since the underlying event type describes pim power on and off operation events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of pimPowerOnOpTrap, pimPowerCycleTrap, and pimPowerCycleOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1118
pimHwEventTrapEncapsulates generic events from hardware. This trap is driven by 'Blade <framename>/pim<1..4> non-sensor Event' event types. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1119
pimVoltageUpperTrapEncapsulates pim critical high voltage sensor events. This trap is driven by 'Blade <framename>/pim<1..4> <voltage-sensor-name> Critical High Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces pimHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1120
pimVoltageLowerTrapEncapsulates pim critical low voltage sensor events. This trap is driven by 'Blade <framename>/pim<1..4> <voltage-sensor-name> Critical Low Event' event types. The sensorValue and sensorThreshold fields are ingeter representations of real numbers. The real numbers are multiplied by 100 and rounded to produce an integer, thus 0.530 => 53. This trap replaces pimHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1121
pimFanSpeedUpperTrapEncapsulates pim critical high fan speed sensor events. This trap is driven by 'Blade <framename>/pim<1..4> <fan-sensor-name> Critical High Event' event types. This trap replaces pimHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1122
pimFanSpeedLowerTrapEncapsulates pim critical low fan speed sensor events. This trap is driven by 'Blade <framename>/pim<1..4> <fan-sensor-name> Critical Low Event' event types. This trap replaces pimHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1123
pimTempUpperTrapEncapsulates pim critical high temperature sensor events. This trap is driven by 'Blade <framename>/pim<1..4> <temp-sensor-name> Critical High Event' event types. This trap replaces pimHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1124
pimTempLowerTrapEncapsulates pim critical low temperature sensor events. This trap is driven by 'Blade <framename>/pim<1..4> <temp-sensor-name> Critical Low Event' event types. This trap replaces pimHwThreshTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1125
globalPoolCreatedTrapThe notification generated when a global pool is created. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1201
globalPoolDeletedTrapThe notification generated when a global pool is deleted. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1202
localPoolCreatedTrapThe notification generated when a local pool is created. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1203
localPoolDeletedTrapThe notification generated when a local pool is deleted. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1204
poolConfigChangedTrapThe notification generated when a pool configuration is changed. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1205
poolPBladeArrivedTrapThe notification generated when a pool pBlade is arrived. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1206
poolPBladeDepartedTrapThe notification generated when a pool pBlade is departed. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1207
diskPartitionedTrapThe notification generated when a disk is partitioned. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1301
diskWinPeTrapThe notification generated when the WinPe image is installed on a disk. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1302
diskRootedTrapThe notification generated when a root image is installed on a disk. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1303
diskOpTrapThe notification generated when an operation is performed on a disk Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1304
vBladePowerOnTrapThe notification generated when a vBlade is powered on. This trap is driven by 'Blade <framename>/p<1|2> Power Status Trap' Trap types describing power on Traps. Since the underlying Trap type describes vBlade power on and off Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladePowerOffTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1403
vBladePowerOffTrapThe notification generated when a vBlade is powered off. This trap is driven by 'Blade <framename>/p<1|2> Power Status Trap' Trap types describing power on Traps. Since the underlying Trap type describes sBlade power on and off Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladePowerOnTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1404
vBladeShutdownTrapThe notification generated when a vBlade has been shut down. This trap is driven by 'blade.status.monitor.Trap' Trap types that describe a vBlade transition from the shutting down state to the shutdown state. This Trap type is not user visible, and will not appear in CLI or GUI Trap quieries. The trap exists to satisfy early requirements documents. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1406
vBladeHwEventTrapEncapsulates generic events from hardware. This trap is driven by 'Blade <framename>/p<1..24> non-sensor Event' event types that do not indicate panic, commanded shutdown, commanded reboot, or init level events. Examples message contents include: OEM Type 0xe0, value = 0x64:0x21:0xce:0xe0:0x1d:0x00:0x00:0x00... bmc reset deasserted, value = 0x0211 system booted Contact EES for more specific information. Since the underlying event type describes vBlade all non-sensor hardware events, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level events, enabling/disabling this SNMP trap as an event action is bound to the enabling/disabling of vBladePanicTrap, vBladeCmdShutdownTrap, vBladeCmdRebootTrap, vBladeCmdHaltTrap, and vBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1411
vBladeCmdRebootTrapEncapsulates hardware Traps indicating intentional vBlade reboot. This trap is driven by 'Blade <framename>/p<1..24> non-sensor Trap' Trap types that describe commanded reboots. Contact EES for more specific information. Since the underlying Trap type describes vBlade non-sensor hardware Traps, and since there are specific traps for panic, commanded shutdown, commanded reboot, and init level Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladeHwTrapTrap, vBladeCmdShutdownTrap, vBladeCmdHaltTrap, vBladePanicTrap, and vBladeInitTrap. Severity: 3
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1415
vBladePowerOnOpTrapEncapsulates vBlade power on operation Trap. This trap is driven by 'vBlade <framename>/c<1|2> Hardware Operation Trap' Trap types. Since the underlying Trap type describes vBlade power on and off operation Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladePowerOffOpTrap, vBladePowerCycleTrap, vBladeResetOpTrap, and vBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1424
vBladePowerOffOpTrapEncapsulates vBlade power off operation Trap. This trap is driven by 'vBlade <framename>/c<1|2> Hardware Operation Trap' Trap types. Since the underlying Trap type describes vBlade power on and off operation Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladePowerOnOpTrap, vBladePowerCycleTrap, vBladeResetOpTrap, and vBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1425
vBladePowerCycleOpTrapEncapsulates vBlade power cycle operation Trap. This trap is driven by 'vBlade <framename>/c<1|2> Hardware Operation Trap' Trap types. Power cycle operations are currently not supported for vBlades. Since the underlying Trap type describes vBlade power on and off operation Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladePowerOnOpTrap, vBladePowerCycleTrap, vBladeResetOpTrap, and vBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1426
vBladeResetOpTrapEncapsulates vBlade reset operation Trap. This trap is driven by 'vBlade <framename>/c<1|2> Hardware Operation Trap' Trap types. Since the underlying Trap type describes vBlade power on and off operation Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladePowerOnOpTrap, vBladePowerCycleTrap, vBladePowerCycleOpTrap, and vBladeNMIOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1427
vBladeNMIOpTrapEncapsulates vBlade reset operation Trap. This trap is driven by 'vBlade <framename>/c<1|2> Hardware Operation Trap' Trap types. NMI operations are currently not supported for vBlades. Since the underlying Trap type describes vBlade power on and off operation Traps, enabling/disabling this SNMP trap as an Trap action is bound to the enabling/disabling of vBladePowerOnOpTrap, vBladePowerCycleTrap, vBladePowerCycleOpTrap, and vBladeResetOpTrap. Severity: 5
TRAP-TYPE
.1.3.6.1.4.1.7559.0.1428
management
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1
panManager
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1
panManagerPANNameA textual string identifying the Egenera PAN represented by this PAN Manager agent.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.1
panManagerIdA textual string uniquely identifying the PAN Manager agent.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.2
panManagerHostnameA textual string identifying the hostname on which the master PAN Manager agent is running.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.3
panManagerAgentTypeAn OID representing the agent type of the agent. Possible values include PAN, LPAN, and BladeFrame. NOTE: BladeFrame agent types are deprecated and subject to removal.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.4
agentTypes
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.5
pan
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.5.1
lPan
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.5.2
bladeFrame
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.5.3
roles
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.9
panRoles
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.9.1
panRoleTableA table of PAN panRoles.
SEQUENCE OF PanRoleEntry
.1.3.6.1.4.1.7559.1.1.9.1.1
panRoleEntryA panRoleEntry contains general information about each PAN Role.
PanRoleEntry
.1.3.6.1.4.1.7559.1.1.9.1.1.1
panRoleIndexAn integer value uniquely identifying the PAN role: 1: Administrator, 2: Operator, 3: Monitorro
INTEGER
.1.3.6.1.4.1.7559.1.1.9.1.1.1.1
panRoleNameThe human readable name of the PAN role.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.9.1.1.1.2
panRoleDescriptionThe human readable description of the PAN role.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.9.1.1.1.3
bladeFrameRoles
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.9.2
bladeFrameRoleTableA table of BladeFrame roles. NOTE: BladeFrame roles are deprecated and subject to removal.
SEQUENCE OF BladeFrameRoleEntry
.1.3.6.1.4.1.7559.1.1.9.2.1
bladeFrameRoleEntryA bladeFrameRoleEntry contains general information about each BladeFrame Role. NOTE: BladeFrame roles are deprecated and subject to removal.
BladeFrameRoleEntry
.1.3.6.1.4.1.7559.1.1.9.2.1.1
bladeFrameRoleIndexAn integer value uniquely identifying the BladeFrame role: 1: Administrator, 2: Operator, 3: Monitor NOTE: BladeFrame roles are deprecated and subject to removal.ro
INTEGER
.1.3.6.1.4.1.7559.1.1.9.2.1.1.1
bladeFrameRoleBladeFrameIndexThe bladeFrameIndex value of the BladeFrame that this role applies to. NOTE: BladeFrame roles are deprecated and subject to removal.ro
INTEGER
.1.3.6.1.4.1.7559.1.1.9.2.1.1.2
bladeFrameRoleNameThe human readable name of the BladeFrame role. NOTE: BladeFrame roles are deprecated and subject to removal.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.9.2.1.1.3
bladeFrameRoleDescriptionThe human readable description of the BladeFrame role. NOTE: BladeFrame roles are deprecated and subject to removal.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.9.2.1.1.4
lpanRoles
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.9.3
lpanRoleTableA table of LPAN roles.
SEQUENCE OF LpanRoleEntry
.1.3.6.1.4.1.7559.1.1.9.3.1
lpanRoleEntryA lpanRoleEntry contains general information about each LPAN Role.
LpanRoleEntry
.1.3.6.1.4.1.7559.1.1.9.3.1.1
lpanRoleIndexAn integer value uniquely identifying the LPAN role: 1: Administrator, 2: Operator, 3: Monitorro
INTEGER
.1.3.6.1.4.1.7559.1.1.9.3.1.1.1
lpanRoleLpanIndexThe lpanIndex of value of the LPAN that this role applies to.ro
INTEGER
.1.3.6.1.4.1.7559.1.1.9.3.1.1.2
lpanRoleNameThe human readable name of the LPAN role.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.9.3.1.1.3
lpanRoleDescriptionThe human readable description of the BladeFrame role.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.9.3.1.1.4
userTableA table of PAN users.
SEQUENCE OF UserEntry
.1.3.6.1.4.1.7559.1.1.10
userEntryA UserEntry contains general information about each user in the Egenera PAN.
UserEntry
.1.3.6.1.4.1.7559.1.1.10.1
userIndexAn integer value uniquely identifying the user.ro
INTEGER
.1.3.6.1.4.1.7559.1.1.10.1.1
userNameThe username for this user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.10.1.2
userFullNameThe full name for this user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.10.1.3
userTitleThe title of this user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.10.1.4
userDescriptionThe description of this user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.10.1.5
userDepartmentThe department of this user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.10.1.6
userEmailThe email address for this user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1.10.1.7
userRoleTableA table indicating the set of roles that each user belongs to. There are three types of roles; Administrator, Operator, and Monitor. Each of these roles exists for each LPAN, for each BladeFrame, and for the PAN. NOTE: BladeFrame roles are deprecated and subject to removal.
SEQUENCE OF UserRoleEntry
.1.3.6.1.4.1.7559.1.1.12
userRoleEntryEach UserRoleEntry indicates a role that a user belongs to.
UserRoleEntry
.1.3.6.1.4.1.7559.1.1.12.1
userRoleUserIndexThe userIndex of the user that belongs to this role.ro
INTEGER
.1.3.6.1.4.1.7559.1.1.12.1.1
userRoleIndexAn integer index identifying this user/role relationship.ro
INTEGER
.1.3.6.1.4.1.7559.1.1.12.1.2
userRoleRoleOidThe fully qualified index OID of the role assigned to this user. The OID will uniquely identify a panRoleIndex, bladeFrameRoleIndex, or lpanRoleIndex instance. NOTE: BladeFrame roles are deprecated and subject to removal.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1.12.1.3
bladeFrames
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.2
bladeFramesInPANThe number of BladeFrames in the Egenera PAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.1
bladeFrameTableA list of BladeFrame entries. The number of entries is given by the value of bladeFramesInPAN. This is a sparse table.
SEQUENCE OF BladeFrameEntry
.1.3.6.1.4.1.7559.1.2.2
bladeFrameEntryA BladeFrame entry contains general information about each BladeFrame in the Egenera PAN.
BladeFrameEntry
.1.3.6.1.4.1.7559.1.2.2.1
bladeFrameIndexAn integer value uniquely identifying the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.1
bladeFrameNameA textual string identifying the BladeFrame.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.2.1.2
bladeFrameHealthStatusAn indication of the health of the BladeFrame.ro
HealthStatusType
.1.3.6.1.4.1.7559.1.2.2.1.3
bladeFrameUpTimeThe amount of time that the BladeFrame has been up.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.2.2.1.4
bladeFrameNumControlBladesThe number of cBlades present in the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.5
bladeFrameMaxControlBladesThe maximum number of cBlades that may be present in the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.6
bladeFrameNumSwitchBladesThe number of sBlades contained in the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.7
bladeFrameMaxSwitchBladesThe maximum number of sBlades that may be contained in the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.8
bladeFrameNumProcessingBladesThe number of pBlades contained in the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.9
bladeFrameMaxProcessingBladesThe maximum number of pBlades that may be contained in the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.10
bladeFrameTypeThe type of BladeFrame managed by this agent.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.2.1.11
bladeFramePIMVoltageTriggerIf the BladeFrame is equiped with PIMs, this column will represent the PIM voltage threshold for PIM power failoverro
INTEGER
.1.3.6.1.4.1.7559.1.2.2.1.12
bladeFrameRoleThe role of this BladeFrame in the PAN; either pan-bf-master(1) or bf-master(3)ro
PlatformRole
.1.3.6.1.4.1.7559.1.2.2.1.13
blades
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.2.3
cBlades
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.2.3.1
cBladeTableA list of cBlade entries conaining information for Control Blades in the Egenera PAN.
SEQUENCE OF CBladeEntry
.1.3.6.1.4.1.7559.1.2.3.1.1
cBladeEntryA cBlade entry contains information for cBlades in the Egenera PAN.
CBladeEntry
.1.3.6.1.4.1.7559.1.2.3.1.1.1
cBladeIndexAn integer value uniquely identifying the cBlade within the BladeFrame. This corresponds to the physical location of the cBlade within the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.1.1.1
cBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the Blade Frame that hosts this cBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.1.1.2
cBladeNameA textual string identifying cBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.3
cBladeSerialNumberDescribes the serial number of this cBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.4
cBladePartNumberDescribes the part number of this cBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.5
cBladePowerStatusThe power status of the cBlade.ro
PowerStatusType
.1.3.6.1.4.1.7559.1.2.3.1.1.1.6
cBladePowerSupplyThe name of the power supply used by this cBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.7
cBladeMasterStatusTrue if this cBlade is a Frame master, false if this cBlade is a Frame slavero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.8
cBladeActiveStatusIndicates whether or not the cBlade is active.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.9
cBladeEnabledStatusIndicates whether the cBlade is enabled or disabled.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.10
cBladeSelectedStatusIndicates whether the cBlade is selected.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.11
cBladeRecognizedStatusIndicates whether the blade has been recognized by the PAN Manager.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.12
cBladeHealthStatusAn indication of the health of the BladeFrame.ro
HealthStatusType
.1.3.6.1.4.1.7559.1.2.3.1.1.1.13
cBladeUpTimeThe amount of time that the BladeFrame has been up.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.2.3.1.1.1.14
cBladeSwitchPowerStatusIndicates the power status of the daughter switch card for cBlade ES blades in the BladeFrame ES. This object does not appear on non BladeFrame ES systems.ro
PowerStatusType
.1.3.6.1.4.1.7559.1.2.3.1.1.1.15
cBladeRoleIndicates the role of the cBlade in the PAN.ro
PlatformRole
.1.3.6.1.4.1.7559.1.2.3.1.1.1.16
cBladeStatsTableA list of cBlade Monitor entries containing runtime statistics for cBlades.
SEQUENCE OF CBladeStatsEntry
.1.3.6.1.4.1.7559.1.2.3.1.2
cBladeStatsEntryA cBlade Monitor entry contains runtime statistics for cBlades.
CBladeStatsEntry
.1.3.6.1.4.1.7559.1.2.3.1.2.1
cBladeStatsUpTimeThe uptime in 1/100ths of a second for this cBlade.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.2.3.1.2.1.1
cBladeStatsLoadAvg1100 * the average number of jobs in the run queue over the previous minute.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.2
cBladeStatsLoadAvg5100 * the average number of jobs in the run queue over the previous five minutes.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.3
cBladeStatsLoadAvg15100 * the average number of jobs in the run queue over the previous fifteen minutes.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.4
cBladeStatsCpuUserThe number of (1/100)ths of a second that the cBlade spent in user mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.5
cBladeStatsCpuSystemThe number of (1/100)ths of a second that the cBlade spent in system mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.6
cBladeStatsCpuIdleThe number of (1/100)ths of a second that the cBlade spent in idle mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.7
cBladeStatsLoadScaleThe load scale.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.8
cBladeStatsNumProcsThe number of processes running on the cBlade.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.9
cBladeStatsLastPidThe highest allocated process ID on the cBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.2.1.10
cBladeStatsContextSwitchThe number of context switches undergone by this cBlade since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.11
cBladeStatsInterruptThe number of interrupts encountered by this cBlade since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.12
cBladeStatsMemTotalThe total amount of physical RAM in kB for this cBlade.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.13
cBladeStatsMemFreeThe amount of free physcial RAM in kB for this cBlade.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.14
cBladeStatsSwapTotalThe total amount of configured swap memory in kB for this cBlade.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.15
cBladeStatsSwapFreeThe amount of free swap memory in kB for this cBlade.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.2.1.16
cBladeStatsPageInThe number of pages paged in since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.17
cBladeStatsPageOutThe number of pages paged out since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.18
cBladeStatsSwapInThe number of swap pages paged in since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.19
cBladeStatsSwapOutThe number of swap pages paged out since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.20
cBladeStatsDiskReadsThe number of disk reads since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.21
cBladeStatsDiskWritesThe number of disk writes since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.22
cBladeStatsDiskBlkReadsThe number of 1 kB blocks read from disk since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.23
cBladeStatsDiskBlkWritesThe number of of 1 kB blocks written to disk since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.24
cBladeStatsCpuUserNiceThe number of (1/100)ths of a second that the pServer spent in user nice mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.2.1.25
cBladeCpuTableA list of CPU statisitcs for each CPU on each cBlade.
SEQUENCE OF CBladeCpuEntry
.1.3.6.1.4.1.7559.1.2.3.1.3
cBladeCpuEntryStatistics for each CPU on the cBlade.
CBladeCpuEntry
.1.3.6.1.4.1.7559.1.2.3.1.3.1
cBladeCpuIndexAn integer uniquely identifying this CPU within the cBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.3.1.1
cBladeCpuCBladeIndexAn integer value identifying the cBladeIndex value of the cBlade that hosts this CPU.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.3.1.2
cBladeCpuLPanIndexThis object is deprecated.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.3.1.3
cBladeCpuModelNameA textual string representing the CPU model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.3.1.4
cBladeCpuModelAn integer value representing the CPU model.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.3.1.5
cBladeCpuFamilyAn integer value representing the CPU family.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.3.1.6
cBladeCpuVendorIdA textual string representing the CPU vendor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.3.1.7
cBladeCpuMhzThe speed of the CPU in Mhz.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.3.1.8
cBladeCpuCacheSizeThe cache size of the CPU in MB.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.3.1.9
cBladeCpuNameA textual string uniquely identifying this CPU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.3.1.10
cBladeCpuUserThe number of (1/100)ths of a second that this CPU spent in user mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.3.1.11
cBladeCpuUserNiceThe number of (1/100)ths of a second that this CPU spent in user nice mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.3.1.12
cBladeCpuSystemThe number of (1/100)ths of a second that this CPU spent in system mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.3.1.13
cBladeCpuIdleThe number of (1/100)ths of a second that this CPU spent in idle mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.3.1.14
cBladeDiskTableA list of disk statisitcs for each disk on the cBlade.
SEQUENCE OF CBladeDiskEntry
.1.3.6.1.4.1.7559.1.2.3.1.4
cBladeDiskEntryDisk statisitcs for each disk on the cBlade.
CBladeDiskEntry
.1.3.6.1.4.1.7559.1.2.3.1.4.1
cBladeDiskNameOctetsAn octet string representing the device special file name representing this disk.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.2.3.1.4.1.1
cBladeDiskCBladeIndexAn integer value identifying the cBladeIndex value of the cBlade that utilizes this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.4.1.2
cBladeDiskBladeFrameIndexAn integer value indentifying the bladeFrameIndex value of the BladeFrame that hosts this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.4.1.3
cBladeDiskNameThe human readable device special file name representing this disk.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.4.1.4
cBladeDiskBlocksThe size of this disk in 1kB blocksro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.4.1.5
cBladeDiskMajorThe major ID of this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.4.1.6
cBladeDiskMinorThe minor ID of this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.4.1.7
cBladePartitionTableA list of partition statisitcs for each partition on the cBlade.
SEQUENCE OF CBladePartitionEntry
.1.3.6.1.4.1.7559.1.2.3.1.5
cBladePartitionEntryPartition statisitcs for each partition on the cBlade.
CBladePartitionEntry
.1.3.6.1.4.1.7559.1.2.3.1.5.1
cBladePartitionNameOctetsAn octet string representing the device special file name representing this disk.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.2.3.1.5.1.1
cBladePartitionCBladeIndexAn integer value identifying the cBladeIndex value of the cBlade that utilizes this disk partition.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.5.1.2
cBladePartitionLPanIndexThis object is deprecated.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.5.1.3
cBladePartitionNameA textual string identifying the device file that represents this partition.ro
DisplayString
.1.3.6.1.4.1.7559.1.2.3.1.5.1.4
cBladePartitionBlocksThe size of this partition in 1kB blocksro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.5.1.5
cBladePartitionMajorThe major ID of this partition.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.5.1.6
cBladePartitionMinorThe minor ID of this partition.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.5.1.7
cBladePartitionFSBlocksIf the partition contains a mounted filesystem, filesystem size in 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.5.1.8
cBladePartitionFSUsedBlocksIf the partition contains a mounted filesystem, the number of used 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.5.1.9
cBladePartitionFSAvailableBlocksIf the partition contains a mounted filesystem, the number of available 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.5.1.10
cBladePartitionFSUtilIf the partition contains a mounted filesystem, the number of available 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.2.3.1.5.1.11
cBladeEthTablephysical Network Interface Cards (NICs) on a BladeFrame's cBlades (cBlades), used for creating rEths. This table provides information similar to that found with the 'eth' command. Note that this excludes eth0, the management NIC. cBlades contain Ethernet NICs for IP communication. This can include: o Gigabit Ethernet connections, either copper or fibre (for I/O) o 10/100/1000 Ethernet connections (for management) For more information about cBlade configuration options, refer to the Egenera web site (www.egenera.com) or contact Egenera Enterprise Services (EES).
SEQUENCE OF CBladeEthEntry
.1.3.6.1.4.1.7559.1.2.3.1.6
cBladeEthEntryInformation specific to each cBlade Eth in the PAN.
CBladeEthEntry
.1.3.6.1.4.1.7559.1.2.3.1.6.1
cBladeEthIndexAn integer value uniquely identifying the cBladeEth within the cBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.6.1.1
cBladeEthCBladeIndexAn integer value identifying the cBladeIndex value of the cBlade that hosts this Eth.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.6.1.2
cBladeEthBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this Eth.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.6.1.3
cBladeEthNameA human readable string uniquely identifying the cBlade Eth.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.4
cBladeEthFullNameA human readable string uniquely identifying the cBlade Eth, including the host cBlade and BladeFrame.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.5
cBladeEthHwMACAddressOctetsAn encoding of the cBlade Eth hardware MAC address.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.6
cBladeEthHwMACAddressStringA human readable string representing the cBlade Eth hardware MAC address in the form: '6E:4A:1F:00:01:06'.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.7
cBladeEthSwMACAddressOctetsThis object is deprecated. As of release 5.0, software MA addresses are not supported on cBlade eths.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.8
cBladeEthSwMACAddressStringThis object is deprecated. As of release 5.0, software MA addresses are not supported on cBlade eths.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.9
cBladeEthNICTypeSpecifies the cBlade ETH NIC type, such as e100 or e1000.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.10
cBladeEthFilteredThis object is deprecated. As of release 5.0, filtered mode is not supported on cBlade eths.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.11
cBladeEthUplinkNameA human readable string that a PAN or BladeFrame Administrator assigns to describe the uplink port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.6.1.12
cBladeEthUplinkPortAn integer value that a PAN or BladeFrame Administrator assigns to identify the uplink port.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.6.1.13
cBladeEthLinkStateThe Link State of the Eth.ro
InterfaceOperStatus
.1.3.6.1.4.1.7559.1.2.3.1.6.1.14
cBladeEthRethStatusThe State of the Eth with respect to REth membership.ro
EthRethStatus
.1.3.6.1.4.1.7559.1.2.3.1.6.1.15
cBladeEthVLANTableA list of VLAN IDs and descriptions associated with each Eth.
SEQUENCE OF CBladeEthVLANEntry
.1.3.6.1.4.1.7559.1.2.3.1.7
cBladeEthVLANEntryInformation specific to each VLAN for cBlade cBladeEths.
CBladeEthVLANEntry
.1.3.6.1.4.1.7559.1.2.3.1.7.1
cBladeEthVLANIdspecifies a VLAN ID assigned to the uplink port on the physical network component connected to the cBlade NICro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.7.1.1
cBladeEthVLANEthIndexAn integer value identifying the cBladeEthIndex value of the cBlade Eth that hosts this Eth VLAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.7.1.2
cBladeEthVLANcBladeIndexAn integer value identifying the cBladeIndex value of the cBlade that hosts this Eth VLAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.7.1.3
cBladeEthVLANBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this Eth VLAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.7.1.4
cBladeEthVLANEthNameThe full name of the ethernet interface associated with this VLAN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.7.1.5
cBladeEthVLANNameA human readable string that a PAN or BladeFrame Administrator assigns to the VLAN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.7.1.6
cBladeVEthStatsTableA list of interface statisitcs for each virtual interface in the cBlade. Since REths remove their composit Eths from the Linux network stack, physical Eth statistics are not avaialble. This table exports statistics for cBlade Eths, including the internal and external management network VEths.
SEQUENCE OF CBladeVEthStatsEntry
.1.3.6.1.4.1.7559.1.2.3.1.8
cBladeVEthStatsEntryVEthStats statisitcs for each virtual interface in the cBlade.
CBladeVEthStatsEntry
.1.3.6.1.4.1.7559.1.2.3.1.8.1
cBladeVEthIndexAn integer value uniquely identifying the VEth within the cBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.8.1.1
cBladeVEthCBladeIndexThe cBladeIndex value of the cBlade hosting this VEth.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.8.1.2
cBladeVEthBladeFrameIndexThe bladeFrameIndex value of the BladeFrame hosting this VEth.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.8.1.3
cBladeVEthNameA string uniquely identifying this VEth on this cBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.8.1.4
cBladeVEthStatsInBytesThe number of bytes received on this interface since interface resetro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.5
cBladeVEthStatsInPacketsThe number of packets received on this interface since interface resetro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.6
cBladeVEthStatsInErrsThe number of errors received on this interface since interface resetro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.7
cBladeVEthStatsInDropsThe number of dropped incoming packets on this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.8
cBladeVEthStatsInOverrunThe number of overrun incoming packets on this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.9
cBladeVEthStatsInMulticastThe number of multicast packets received on this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.10
cBladeVEthStatsOutBytesThe number of bytes transmitted from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.11
cBladeVEthStatsOutPacketsThe number of packets transmitted from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.12
cBladeVEthStatsOutErrsThe number of errors encountered while transmitting from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.13
cBladeVEthStatsOutDropsThe number of dropped packets intended for transmission from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.14
cBladeVEthStatsOutOverrunThe number of overrun packets intended for transmission from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.15
cBladeVEthStatsOutCollisionsThe number of collisions detetced while transmitting from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.16
cBladeVEthStatsOutCarrierDctFailThe number of carrier detect failures detetced while transmitting from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.17
cBladeVEthStatsOutCompressedThe number of compressed packets transmitted from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.2.3.1.8.1.18
cBladeVEthStatsOperStatusThe operational state of the interface.ro
InterfaceOperStatus
.1.3.6.1.4.1.7559.1.2.3.1.8.1.19
cBladeVEthIpTableA list of IP addresses, broadcast addresses, and nework masks configured on each cBlade VEth interface.
SEQUENCE OF CBladeVEthIpEntry
.1.3.6.1.4.1.7559.1.2.3.1.9
cBladeVEthIpEntrythe IP address, broadcast address, and network mask for a cBlade VEth cBlade or alias.
CBladeVEthIpEntry
.1.3.6.1.4.1.7559.1.2.3.1.9.1
cBladeVEthIpAliasNameThe name of this network interface or alias, i.e. lo, vVEth31, VEth10:1ro
DisplayString
.1.3.6.1.4.1.7559.1.2.3.1.9.1.1
cBladeVEthIpVEthIndexAn integer value identifying the cBladeVEthIndex of the cBlade VEth that hosts this IP configuraion.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.9.1.2
cBladeVEthIpCBladeIndexAn integer value identifying the cBladeIndex of the cBlade that hosts this IP configuraion.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.9.1.3
cBladeVEthIpBladeFrameIndexAn integer value identifying the bladeFrameIndex of the BladeFrame that hosts this IP configuraion.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.9.1.4
cBladeVEthIpAddressThe IP address configured on this cBlade VEth (or alias)ro
IpAddress
.1.3.6.1.4.1.7559.1.2.3.1.9.1.5
cBladeVEthIpBroadcastThe broadcast address configured on this cBlade VEth (or alias)ro
IpAddress
.1.3.6.1.4.1.7559.1.2.3.1.9.1.6
cBladeVEthIpMaskThe network mask configured on this cBlade VEth (or alias)ro
IpAddress
.1.3.6.1.4.1.7559.1.2.3.1.9.1.7
cBladeControlTableA list of cBlade entries containing controls for Control Blades in discovered Egenera BladeFrames.
SEQUENCE OF CBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.1.10
cBladeControlEntryAn cBlade Control entry contains controls for Control Blades in the Egenera PAN.
CBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.1.10.1
cBladeControlPowerUpWhen set to 1, initiates a power up operation on this Control Blade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.1
cBladeControlPowerDownWhen set to 1, initiates a power down operation on this Control Blade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.2
cBladeControlColdResetWhen set to 1, initiates a cold reset operation on this Control Blade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.3
cBladeControlWarmResetWhen set to 1, initiates a warm reset operation on this Control Blade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.4
cBladeControlNmiWhen set to 1, initiates an non-maskable interrupt operation on this cBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.5
cBladeControlSwitchPowerUpWhen set to 1, initiates a power down operation on the switch component of this cBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.6
cBladeControlSwitchPowerDownWhen set to 1, initiates a power up operation on the switch component of this cBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.7
cBladeControlSwitchPowerCycleWhen set to 1, initiates a power cycle operation on the switch component of this cBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.10.1.8
cBladeHwMonitorTableA list of cBlade monitor entries for each cBlade in the PAN. Voltage is measured in Volts, Temperature in degrees Celcius, and fan speed in Revolutions Per Minute
SEQUENCE OF CBladeMonitorEntry
.1.3.6.1.4.1.7559.1.2.3.1.11
cBladeMonitorEntryAttributes of a specific cBlade hardware monitor.
CBladeMonitorEntry
.1.3.6.1.4.1.7559.1.2.3.1.11.1
cBladeHwMonitorIndexAn integer value uniquely identifying the monitor within the cBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.11.1.1
cBladeHwMonitorNameAn String identifying the name of the hardware monitor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.11.1.2
cBladeHwMonitorTypeAn integer encoding of the monitor type; voltage, temperature, or fanspeed.ro
HardwareMonitorType
.1.3.6.1.4.1.7559.1.2.3.1.11.1.3
cBladeHwMonitorValueThe integer representation of the current hardware sensor value. Voltage values are multiplied by 100 and rounted to convert from float to integer. Thus 0.530 => 53ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.11.1.4
cBladeHwMonitorValueDenomonatorThe integer representation of the denomonator required to convert the integer incoding of the sensor value to the float value. For voltage sensors, this value is 100, for all other sensors, this value is 1.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.11.1.5
cBladeHbaTablephysical HBA on a BladeFrame's cBlades (cBlades).
SEQUENCE OF CBladeHbaEntry
.1.3.6.1.4.1.7559.1.2.3.1.12
cBladeHbaEntryInformation specific to each HBA in the PAN.
CBladeHbaEntry
.1.3.6.1.4.1.7559.1.2.3.1.12.1
cBladeHbaIndexAn integer value uniquely identifying the HBA within the cBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.12.1.1
cBladeHbaCBladeIndexAn integer value identifying the cBladeIndex value of the cBlade that hosts this HBA.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.12.1.2
cBladeHbaBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this HBA.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.1.12.1.3
cBladeHbaNameA human readable string uniquely identifying the cBlade HBA.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.12.1.4
cBladeHbaStatusA human readable string identifying the status of the cBlade HBA.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.12.1.5
cBladeHbaEnableStateIndicates whether the cBlade HBA is enabled.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.1.12.1.6
sBlades
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.2.3.2
sBladeTableA list of sBlade entries containing information for Switch Blades in the Egenera PAN.
SEQUENCE OF SBladeEntry
.1.3.6.1.4.1.7559.1.2.3.2.1
sBladeEntryA sBlade entry contains information for sBlades in the Egenera PAN.
SBladeEntry
.1.3.6.1.4.1.7559.1.2.3.2.1.1
sBladeIndexAn integer value uniquely identifying the sBlade within the BladeFrame. This corresponds to the physical location of the sBlade within the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.1.1.1
sBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this sBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.1.1.2
sBladeNameA textual string identifying the sBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.3
sBladeSerialNumberDescribes the serial number of this sBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.4
sBladePartNumberDescribes the part number of this sBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.5
sBladePowerStatusThe power status of the sBlade.ro
PowerStatusType
.1.3.6.1.4.1.7559.1.2.3.2.1.1.6
sBladePowerSupplyThe name of the power supply used by this sBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.7
sBladeMasterStatusIndicates that the switch is acting as the master switch.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.8
sBladeActiveStatusIndicates whether or not the sBlade is active.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.9
sBladeEnabledStatusIndicates whether the sBlade is enabled or disabled.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.10
sBladeSelectedStatusIndicates whether the sBlade is selected.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.11
sBladeRecognizedStatusIndicates whether the blade has been recognized by the PAN Manager.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.12
sBladeHealthStatusAn indication of the health of the BladeFrame.ro
HealthStatusType
.1.3.6.1.4.1.7559.1.2.3.2.1.1.13
sBladeUpTimeThe amount of time that the BladeFrame has been up.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.2.3.2.1.1.14
sBladeControlTableA list of sBlade Control entries containing controls for sBlades the Egenera PAN.
SEQUENCE OF SBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.2.2
sBladeControlEntryA sBlade Control entry contains controls for sBlades in the Egenera PAN.
SBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.2.2.1
sBladeControlPowerUpWhen set to 1, initiates a power up operation on this sBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.2.1.1
sBladeControlPowerDownWhen set to 1, initiates a power down operation on this sBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.2.1.2
sBladeHwMonitorTableA list of sBlade monitor entries for each sBlade in the PAN.
SEQUENCE OF SBladeMonitorEntry
.1.3.6.1.4.1.7559.1.2.3.2.3
sBladeMonitorEntryAttributes of a specific sBlade hardware monitor.
SBladeMonitorEntry
.1.3.6.1.4.1.7559.1.2.3.2.3.1
sBladeHwMonitorIndexAn integer value uniquely identifying the monitor within the sBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.3.1.1
sBladeHwMonitorNameAn String identifying the name of the hardware monitor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.3.1.2
sBladeHwMonitorTypeAn integer encoding of the monitor type; voltage, temperature, or fanspeed.ro
HardwareMonitorType
.1.3.6.1.4.1.7559.1.2.3.2.3.1.3
sBladeHwMonitorValueThe integer representation of the current hardware sensor value. Voltage values are multiplied by 100 and rounted to convert from float to integer. Thus 0.530 => 53ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.3.1.4
sBladeHwMonitorValueDenomonatorThe integer representation of the denomonator required to convert the integer incoding of the sensor value to the float value. For voltage sensors, this value is 100, for all other sensors, this value is 1.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.3.1.5
sBladeEthTablephysical Network Interface Cards (NICs) on a BladeFrame's sBlades (sBlades).
SEQUENCE OF SBladeEthEntry
.1.3.6.1.4.1.7559.1.2.3.2.4
sBladeEthEntryInformation specific to each sBlade Eth in the PAN.
SBladeEthEntry
.1.3.6.1.4.1.7559.1.2.3.2.4.1
sBladeEthIndexAn integer value uniquely identifying the sBlade within the sBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.4.1.1
sBladeEthSBladeIndexAn integer value identifying the sBladeIndex value of the sBlade that hosts this Eth.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.4.1.2
sBladeEthBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this Eth.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.4.1.3
sBladeEthNameA human readable string uniquely identifying the sBlade Eth.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.4.1.4
sBladeEthFullNameA human readable string uniquely identifying the sBlade Eth, including the host sBlade and BladeFrame.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.4.1.5
sBladeEthHwMACAddressOctetsAn encoding of the sBlade Eth hardware MAC address.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.4.1.6
sBladeEthHwMACAddressStringA human readable string representing the sBlade Eth hardware MAC address in the form: '6E:4A:1F:00:01:06'.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.4.1.7
sBladeEthNICTypeSpecifies the sBlade ETH NIC type, such as e100 or e1000.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.4.1.10
sBladeEthFilteredindicates whether filtered mode is enabled. unfiltered mode allows the sBlade NICs to admit all external network traffic sent by their connecting switch. Filtered mode enables the sBlade NICs to filter incoming traffic based on a single MAC address assigned to the NIC. Unfiltered mode is the default configuration.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.4.1.11
sBladeEthUplinkNameA human readable string that a PAN or BladeFrame Administrator assigns to describe the uplink port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.4.1.12
sBladeEthUplinkPortAn integer value that a PAN or BladeFrame Administrator assigns to identify the uplink port.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.4.1.13
sBladeEthLinkStateThe Link State of the Eth.ro
InterfaceOperStatus
.1.3.6.1.4.1.7559.1.2.3.2.4.1.14
sBladeEthRethStatusThe State of the Eth with respect to REth membership.ro
EthRethStatus
.1.3.6.1.4.1.7559.1.2.3.2.4.1.15
sBladeEthVLANTableA list of VLAN IDs and descriptions associated with each Eth.
SEQUENCE OF SBladeEthVLANEntry
.1.3.6.1.4.1.7559.1.2.3.2.5
sBladeEthVLANEntryInformation specific to each VLAN for sBlade sBladeEths.
SBladeEthVLANEntry
.1.3.6.1.4.1.7559.1.2.3.2.5.1
sBladeEthVLANIdspecifies a VLAN ID assigned to the uplink port on the physical network component connected to the sBlade NICro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.5.1.1
sBladeEthVLANEthIndexAn integer value identifying the sBladeEthIndex value of the sBlade Eth that hosts this Eth VLAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.5.1.2
sBladeEthVLANsBladeIndexAn integer value identifying the sBladeIndex value of the sBlade that hosts this Eth VLAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.5.1.3
sBladeEthVLANBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this Eth VLAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.2.5.1.4
sBladeEthVLANEthNameThe full name of the ethernet interface associated with this VLAN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.5.1.5
sBladeEthVLANNameA human readable string that a PAN or BladeFrame Administrator assigns to the VLAN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.2.5.1.6
pBlades
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.2.3.3
pBladeTableA list of pBlade entries containing information for pBlades the Egenera PAN.
SEQUENCE OF PBladeEntry
.1.3.6.1.4.1.7559.1.2.3.3.1
pBladeEntryAn pBlade entry contains information for Processing Blades in the Egenera PAN.
PBladeEntry
.1.3.6.1.4.1.7559.1.2.3.3.1.1
pBladeIndexAn integer value uniquely identifying the pBlade within the BladeFrame. This corresponds to the physical location of the pBlade within the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.1
pBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this pBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.2
pBladePServerIndexAn integer value identifying the pServerIndex of the pServer running on this pBlade, or -1 if the pBlade is not occupied by a pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.3
pBladeLPanIndexAn integer value identifying the lPanIndex of the LPAN containing the pServer running on this pBlade, or -1 if the pBlade is not occupied by a pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.4
pBladeNameA textual string identifying this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.5
pBladeBladeFrameNameA textual string identifying the BladeFrame containing this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.6
pBladePServerNameA textual string identifying the pServer running on this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.7
pBladeLPanNameA textual string identifying the LPAN containing the pServer running on this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.8
pBladeDescriptionA textual string describing this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.9
pBladeHostNameThe hostname of the PServer running on this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.10
pBladeNumCpusThe number of CPUs on the pBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.11
pBladeCpuSpeedThe speed of the CPUs on the pBlade in Mhz.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.12
pBladeCpuModelA textual string representing the CPU model this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.13
pBladeMemorySizeThe size of the physical RAM installed on the pBlade, in MB.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.14
pBladeCacheThe size of the CPU cache installed on the pBlade, in kB.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.15
pBladeArchitectureDescribes the pBlade hardware architecture.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.16
pBladeSerialNumberDescribes the serial number of this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.17
pBladePartNumberDescribes the part number of this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.18
pBladePowerStatusThe power status of the pBlade.ro
PowerStatusType
.1.3.6.1.4.1.7559.1.2.3.3.1.1.19
pBladePowerSupplyThe name of the power supply used by this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.20
pBladeActiveStatusIndicates whether or not the blade is active.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.21
pBladeAllocationStatusIndicates whether or not the blade is allocated.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.22
pBladeEnabledStatusIndicates whether the blade is enabled or disabled.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.23
pBladeSelectedStatusIndicates whether the blade is selected.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.24
pBladeRecognizedStatusIndicates whether the blade has been recognized by the PAN Manager.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.25
pBladeHealthStatusAn indication of the health of the BladeFrame.ro
HealthStatusType
.1.3.6.1.4.1.7559.1.2.3.3.1.1.26
pBladeInDebuggerIndicates whether or not the kernel kernel on the pBlade has entered the debugger.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.27
pBladeOutOfServiceIndicates whether this pBlade has been designated 'Out Of Service'.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.28
pBladeOutOfServicePendingIndicates whether this pBlade has a pending designation of 'Out Of Service'.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.29
pBladeBootStatusIndicates the boot status of this pBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.30
pBladeUpTimeThe amount of time that the pBlade has been up.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.2.3.3.1.1.31
pBladePoolIndexAn integer value identifying the poolindex of the pool containing the pBlade .ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.1.1.32
pBladeControlTableA list of pBlade entries containing controls for pBlades in the Egenera PAN.
SEQUENCE OF PBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.3.2
pBladeControlEntryAn pBlade entry contains controls for Processing Blades in the Egenera PAN.
PBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.3.2.1
pBladeControlPowerUpWhen set to 1, initiates a power up operation on this Processing Blade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.2.1.1
pBladeControlPowerDownWhen set to 1, initiates a power down operation on this pBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.2.1.2
pBladeControlColdResetWhen set to 1, initiates a cold reset operation on this pBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.2.1.3
pBladeControlWarmResetWhen set to 1, initiates a warm reset operation on this pBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.2.1.4
pBladeControlNmiWhen set to 1, initiates a non-maskable interrupt operation on this pBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.2.1.5
pBladeHwMonitorTableA list of pBlade monitor entries for each pBlade in the PAN.
SEQUENCE OF PBladeMonitorEntry
.1.3.6.1.4.1.7559.1.2.3.3.3
pBladeMonitorEntryA list of pBlade monitor entries for each pBlade in the PAN. Voltage is measured in Volts, Temperature in degrees Celcius, and fan speed in Revolutions Per Minute
PBladeMonitorEntry
.1.3.6.1.4.1.7559.1.2.3.3.3.1
pBladeHwMonitorIndexAn integer value uniquely identifying the monitor within the pBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.3.1.1
pBladeHwMonitorNameAn String identifying the name of the hardware monitor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.3.1.2
pBladeHwMonitorTypeAn integer encoding of the monitor type; voltage, temperature, or fanspeed.ro
HardwareMonitorType
.1.3.6.1.4.1.7559.1.2.3.3.3.1.3
pBladeHwMonitorValueThe integer representation of the current hardware sensor value. Voltage values are multiplied by 100 and rounted to convert from float to integer. Thus 0.530 => 53ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.3.1.4
pBladeHwMonitorValueDenomonatorThe integer representation of the denomonator required to convert the integer incoding of the sensor value to the float value. For voltage sensors, this value is 100, for all other sensors, this value is 1.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.3.1.5
pBladeHwMonitorUnitsMonitor units.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.3.1.6
vBladeTableA list of vBlade entries containing information for vBlades the Egenera PAN.
SEQUENCE OF VBladeEntry
.1.3.6.1.4.1.7559.1.2.3.3.4
vBladeEntryAn vBlade entry contains information for Processing Blades in the Egenera PAN.
VBladeEntry
.1.3.6.1.4.1.7559.1.2.3.3.4.1
vBladeIndexAn integer value uniquely identifying the vBlade within the pBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.1
vBladePBladeIndexAn integer value uniquely identifying the pBladeIndex value of the pBlade hosting this vBlade. The pBladeIndex is the slot of the pBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.2
vBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this vBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.3
vBladePServerIndexAn integer value identifying the pServerIndex of the pServer running on this vBlade, or -1 if the vBlade is not occupied by a pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.4
vBladeLPanIndexAn integer value identifying the lPanIndex of the LPAN containing the pServer running on this vBlade, or -1 if the vBlade is not occupied by a pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.5
vBladeNameA textual string identifying this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.6
vBladeBladeFrameNameA textual string identifying the BladeFrame containing this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.7
vBladePServerNameA textual string identifying the pServer running on this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.8
vBladeLPanNameA textual string identifying the LPAN containing the pServer running on this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.9
vBladeDescriptionA textual string describing this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.10
vBladeHostNameThe hostname of the PServer running on this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.11
vBladeNumCpusThe number of CPUs on the vBlade.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.12
vBladeCpuSpeedThe speed of the CPUs on the vBlade in Mhz.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.13
vBladeCpuModelA textual string representing the CPU model this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.14
vBladeMemorySizeThe size of the physical RAM installed on the vBlade, in MB.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.15
vBladeCacheThe size of the CPU cache installed on the vBlade, in kB.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.16
vBladeArchitectureDescribes the vBlade hardware architecture.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.17
vBladeSerialNumberDescribes the serial number of this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.18
vBladePartNumberDescribes the part number of this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.19
vBladePowerStatusThe power status of the vBlade.ro
PowerStatusType
.1.3.6.1.4.1.7559.1.2.3.3.4.1.20
vBladePowerSupplyThe name of the power supply used by this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.21
vBladeActiveStatusIndicates whether or not the blade is active.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.22
vBladeAllocationStatusIndicates whether or not the blade is allocated.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.23
vBladeHealthStatusAn indication of the health of the BladeFrame.ro
HealthStatusType
.1.3.6.1.4.1.7559.1.2.3.3.4.1.24
vBladeInDebuggerIndicates whether or not the kernel kernel on the vBlade has entered the debugger.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.25
vBladeBootStatusIndicates the boot status of this vBlade.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.26
vBladeUpTimeThe amount of time that the vBlade has been up.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.2.3.3.4.1.27
vBladePoolIndexAn integer value identifying the poolindex of the pool containing the vBlade .ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.4.1.28
vBladeControlTableA list of vBlade entries containing controls for vBlades in the Egenera PAN.
SEQUENCE OF VBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.3.5
vBladeControlEntryAn vBlade entry contains controls for Processing Blades in the Egenera PAN.
VBladeControlEntry
.1.3.6.1.4.1.7559.1.2.3.3.5.1
vBladeControlBootWhen set to 1, initiates a boot operation on this Processing Blade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.5.1.1
vBladeControlShutdownWhen set to 1, initiates a shutdown operation on this vBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.5.1.2
vBladeControlRebootWhen set to 1, initiates a reboot operation on this vBlade. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.5.1.3
vBladeControlNmiWhen set to 1, initiates a non-maskable interrupt operation on this vBlade. When read, returns 0. NMI is currently not supported, this is a no op.rw
INTEGER
.1.3.6.1.4.1.7559.1.2.3.3.5.1.4
pims
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.2.3.4
pimTableA list of PIM entries containing information for PIMs the Egenera PAN.
SEQUENCE OF PIMEntry
.1.3.6.1.4.1.7559.1.2.3.4.1
pimEntryAn PIM entry contains information for PIMs in the Egenera PAN.
PIMEntry
.1.3.6.1.4.1.7559.1.2.3.4.1.1
pimIndexAn integer value uniquely identifying the PIM within the BladeFrame. This corresponds to the physical location of the PIM within the BladeFrame.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.1
pimFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this PIM.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.2
pimNameA textual string identifying this PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.3
pimBladeFrameNameA textual string identifying the BladeFrame containing this PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.4
pimSerialNumberDescribes the serial number of this PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.5
pimPartNumberDescribes the part number of this PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.6
pimFirmWareThe firmware of the PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.7
pimSelectedPowerThe selected power of the PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.8
pimOutputPowerThe output power of the PIM.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.9
pimOutputCurrentThe outpur current of the PIM.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.10
pimPreferredPowerThe preferred power of the PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.11
pimManualPowerPreferenceThe manual power preference of the PIM.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.12
pimCurrentLimitThe current limit of the PIM.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.13
pimPowerLimitThe power limit of the PIM.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.14
pimInputVoltageAThe input voltage A of the PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.15
pimInputVoltageBThe InputVoltageB of the PIM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.16
pimInputFreqThe input frequency of the PIM.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.17
pimVoltageFailoverTriggerRangeThis attribute is deprecated. The trigger value is fixed at 85% of PIM maximum voltagero
INTEGER
.1.3.6.1.4.1.7559.1.2.3.4.1.1.18
pimSelectedStatusIndicates whether or not the PIM is selected.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.3.4.1.1.19
chassisTableA list of Chassis entries describing attributes of non-egenera hardware chassis contained in the PAN. This is a sparse table.
SEQUENCE OF ChassisEntry
.1.3.6.1.4.1.7559.1.2.4
chassisEntryA Chassis entry contains general information about each Chassis in the Egenera PAN.
ChassisEntry
.1.3.6.1.4.1.7559.1.2.4.1
chassisIndexAn integer value uniquely identifying the hardware chassis.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.4.1.1
chassisBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that this chassis contributes to.ro
INTEGER
.1.3.6.1.4.1.7559.1.2.4.1.2
chassisNameA textual string identifying the chassis.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.4.1.3
chassisTypeA textual string identifying the type chassis.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.2.4.1.4
chassisManagementIpThe management IP address of the chassis.ro
IpAddress
.1.3.6.1.4.1.7559.1.2.4.1.5
devices
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3
cdroms
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.1
cdromTableA list of cdrom entries containing information about each cdrom allocated to this LPAN.
SEQUENCE OF CDRomEntry
.1.3.6.1.4.1.7559.1.3.1.1
cdromEntryInformation specific to each cdrom in the PAN, or allocated to the LPAN if LPAN agent.
CDRomEntry
.1.3.6.1.4.1.7559.1.3.1.1.1
cdromIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.1.1.1.1
cdromCBladeIndexThe cBladeIndex value of the cBlade hosting this CD-Rom.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.1.1.2
cdromBladeFrameIndexThe bladeFrameIndex value of the BladeFrame hosting this CD-Rom.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.1.1.3
cdromIdA human readable string consisting of dot separated values of HBA number, BUS ID, target device ID and LUN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.1.1.1.4
cdromLPANIndexThe lpanIndex value of the LPAN this cdrom is allocated to, or 0 if not allocated.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.1.1.5
cdromMajorThe minor number of this CD-Rom device.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.1.1.6
cdromMinorThe minor number of this CD-Rom device.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.1.1.7
cdromVendorA textual string identifying the cdrom vendor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.1.1.1.8
cdromModelA textual string identifying the cdrom model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.1.1.1.9
cdromSerialNumberA textual string providing the serial number of the cdrom.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.1.1.1.10
cdromRevThe firmare revision used by this CD-ROM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.1.1.1.11
cdromEnabledIndicates wether the cdrom is enabled (true), or disabled (false).ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.1.1.1.12
cdromCapacityThe storage capacity of the cdrom in megabytes.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.1.1.13
cdromLPanAllocTableA list of LPAN indicies identifying LPAN cdrom allocations.
SEQUENCE OF CDRomLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.1.2
cdromLPanAllocEntryInformation specific to each pServer cdrom allocation.
CDRomLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.1.2.1
cdromLPanAllocIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN of the cdrom.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.1.2.1.1
cdromLPanAllocBladeFrameIndexThe bladeFrameIndex value of the BladeFrame hosting this CD-ROM.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.2.1.2
cdromLPanAllocCBladeIndexThe cBladeIndex value of the cBlade hosting this CD-ROM.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.2.1.3
cdromLPanAllocLPanIndexThe lpanIndex of the LPAN hosting the LPAN this cdrom is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.2.1.4
cdromLPanAllocEnabledIndicates whether the LPAN cdrom mapping is currently enabled.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.1.2.1.5
cdromPSvrAllocTableA list of LPAN, pServer index pairs identifying pServer cdrom allocations.
SEQUENCE OF CDRomPSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.1.3
cdromPSvrAllocEntryInformation specific to each pServer cdrom allocation.
CDRomPSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.1.3.1
cdromPSvrAllocIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN of the cdrom.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.1.3.1.1
cdromPSvrAllocBladeFrameIndexThe bladeFrameIndex value of the BladeFrame hosting this CD-ROM.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.3.1.2
cdromPSvrAllocCBladeIndexThe cBladeIndex value of the cBlade hosting this CD-ROM.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.3.1.3
cdromPSvrAllocLPanIndexThe lpanIndex of the LPAN hosting the pServer this cdrom is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.3.1.4
cdromPSvrAllocpSvrIndexThe lpanIndex of the pServer hosting the pServer this cdrom is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.1.3.1.5
disks
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.2
diskTableA list of disk entries containing information about each disk allocated to this LPAN.
SEQUENCE OF DiskEntry
.1.3.6.1.4.1.7559.1.3.2.1
diskEntryInformation specific to each disk in the PAN, or allocated to the LPAN if LPAN agent.
DiskEntry
.1.3.6.1.4.1.7559.1.3.2.1.1
diskIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.2.1.1.1
diskIdA human readable string consisting of dot separated values of HBA number, BUS ID, target device ID and LUN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.1.1.2
diskMajorThe major number of this disk device. This object is deprecated and will be removed in future releases.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.2.1.1.3
diskMinorThe minor number of this disk device. This object is deprectated and will be removed in future releasesro
INTEGER
.1.3.6.1.4.1.7559.1.3.2.1.1.4
diskVendorA textual string identifying the disk vendor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.1.1.5
diskModelA textual string identifying the disk model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.1.1.6
diskSerialNumberA textual string providing the serial number of the diskro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.1.1.7
diskRevThe firmare revision used by this disk.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.1.1.8
diskEnabledIndicates wether the disk is enabled (true), or disabled (false).ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.1.1.9
diskCapacityThe storage capacity of the disk in megabytes.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.2.1.1.10
diskDescriptionDisk description string.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.1.1.11
diskLPanAllocTableA list of LPAN indicies identifying LPAN disk allocations.
SEQUENCE OF DiskLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.2.2
diskLPanAllocEntryInformation specific to each LPAN disk allocation.
DiskLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.2.2.1
diskLPanAllocIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN of the disk.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.2.2.1.1
diskLPanAllocLPanIndexThe lpanIndex of the LPAN hosting the LPAN this disk is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.2.2.1.2
diskLPanAllocEnabledIndicates whether the disk is currently enabled within the LPAN.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.2.2.1.3
diskPSvrAllocTableA list of LPAN, pServer index pairs identifying pServer disk allocations.
SEQUENCE OF DiskPSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.2.3
diskPSvrAllocEntryInformation specific to each pServer disk allocation.
DiskPSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.2.3.1
diskPSvrAllocIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN of the disk.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.2.3.1.1
diskPSvrAllocPSvrIndexThe lpanIndex of the pServer hosting the pServer this disk is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.2.3.1.2
diskPSvrAllocLPanIndexThe lpanIndex of the LPAN hosting the pServer this disk is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.2.3.1.3
rEths
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.3
rEthTableA list of rEth entries containing information about each redundant Ethernet (rEth) in the PAN. A rEth is a pair of Ethernet Network Interface Cards (NICs), one on each cBlade, with the same configuration and external connectivity. A rEth provides redundant load-balancing and failover capability for BladeFrame network connectivity. Egenera rEth Naming Conventions ethx@bladeframename/cn Reference to a cBlade Network Interface Card (NIC). BladeFrame naming conventions require you to use a '/' between the BladeFrame name and cBlade number. For example eth1 on cBlade 2 on the BladeFrame named Egenera, would be referred to as 'eth1@Egenera/c2'.
SEQUENCE OF REthEntry
.1.3.6.1.4.1.7559.1.3.3.1
rEthEntryInformation specific to each rEth in the PAN.
REthEntry
.1.3.6.1.4.1.7559.1.3.3.1.1
rEthIndexAn integer value uniquely identifying the rEth within the PANro
INTEGER
.1.3.6.1.4.1.7559.1.3.3.1.1.1
rEthNameA human readable string uniquely identifying the rEth.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.2
rEthPrimaryEthIdentifies the primary Eth of the Reth.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.3
rEthPrimaryEthIndexOidAn encoding of the cBlade Eth BladeFrameIndex, cBladeIndex, and cBladeEth index, uniquely identifying the cBlade Eth configured as the primary Eth.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.3.1.1.4
rEthInterface1Specifies the first cBlade NIC of a rEth.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.5
rEthInterface1IndexOidAn encoding of the cBlade Eth BladeFrameIndex, cBladeIndex, and cBladeEth index, uniquely identifying the cBlade Eth configured as 'interface1'.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.3.1.1.6
rEthInterface2Specifies the second cBlade NIC of a rEth.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.7
rEthInterface2IndexOidAn encoding of the cBlade Eth BladeFrameIndex, cBladeIndex, and cBladeEth index, uniquely identifying the cBlade Eth configured as 'interface2'.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.3.1.1.8
rEthMACAddressOctetsThis object is deprecatedro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.9
rEthMACAddressStringThis object is deprecatedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.10
rEthFlowControlOnIndicates whether flow-control is currently enabled for this rEth.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.11
rEthAutoMACAssignThis object is deprecatedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.3.1.1.12
rEthLoadBalancePolicyDescribes the rEth Load Balancing Policy: pair(1) (default) packets are transmitted on the same cBlade that is receiving packets. inverse(2) packets are transmitted on the failover partner not currently enabled balance(3) packets are transmitted via either cBlade. With this option, a pBlade attempts to load-balance between both cBlades. NOTE: Certain external switches may not allow this configuration. undefined(999)ro
LoadBalanceType
.1.3.6.1.4.1.7559.1.3.3.1.1.13
rEthStateDescribes the current State of the REth: redundant(1) both eths are not failed not-redundant(2) one of the two eths is known to be failed degraded(3) one of the two eths is known to be failed, and the other is unknown failed(4) both eths are known to be failed unknown(999)ro
REthStateType
.1.3.6.1.4.1.7559.1.3.3.1.1.14
rEthFrameIndexAn integer value uniquely identifying the BladeFrame that hosts this rEth. Prior to PAN Manager 5.0, all rEths belonged to the same BladeFrame. With BladeFarms, we need to identify the BladeFrame that hosts each rEth.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.3.1.1.15
rEthMTUSizeDefines the MTU size of a rEth.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.3.1.1.16
vSwitches
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.4
vSwitchTableA Table of information specific to vSwitches within the PAN. vSwitches establish connectivity between pServers and external networks or between pServers. Internal Connectivity - LPAN Administrators can create Eths for pBlade-to-pBlade communication using any vSwitch they have permission to access. If two pServers connect to the same vSwitch, the two pServers can communicate via IP. External Connectivity - BladeFrame architecture only supports external network communication through a Redundant Ethernet (rEth) configuration. PAN or BladeFrame Administrators can only create vSwitches for external connectivity using an uplink configured with the 'reth' command.
SEQUENCE OF VSwitchEntry
.1.3.6.1.4.1.7559.1.3.4.1
vSwitchEntryInformation specific to each vSwitch in the PAN, or allocated to the LPAN if LPAN agent.
VSwitchEntry
.1.3.6.1.4.1.7559.1.3.4.1.1
vSwitchIndexAn integer value uniquely identifying this vSwitchro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.1.1.1
vSwitchNameA human readable string uniquely identifying this switch.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.2
vSwitchRedundantindicates whether or not this vSwitch is configured for uplink redundancy.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.3
vSwitchExternalindicates whether or not this vSwitch is configured provide external IP connectivity.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.4
vSwitchRouterIpThis object is deprecated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.5
vSwitchDHCPProxyIpThis object is deprecated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.6
vSwitchRethNameA textual string identifying the name of the rEth uplink, if configured.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.7
vSwitchRethIndexAn encoding of the rEthIndex value of the rEth uplink, or -1 if none.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.1.1.8
vSwitchUplinkNameThis object is deprecated. As of release 4.0, uplink names and ports are associated with cBlade eths, not vSwitches.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.9
vSwitchUplinkPortThis object is deprecated. As of release 4.0, uplink names and ports are associated with cBlade eths, not vSwitches.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.1.1.10
vSwitchVLANIdspecifies a VLAN ID assigned to the uplink port of this vSwitch, or -1 for nonero
INTEGER
.1.3.6.1.4.1.7559.1.3.4.1.1.11
vSwitchVLANNamespecifies a VLAN Name assigned to the uplink port of this vSwitch.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.12
vSwitchMRethNameA textual string identifying the name of the Mega REth uplink, if configured.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.4.1.1.13
vSwitchMRethIndexAn encoding of the megaREthIndex value of the Mega REth uplink, or -1 if none.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.1.1.14
vSwitchLPanAllocTableA list of LPAN indicies identifying LPAN vSwitch allocations.
SEQUENCE OF VSwitchLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.4.2
vSwitchLPanAllocEntryInformation specific to each LPAN vSwitch allocation.
VSwitchLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.4.2.1
vSwitchLPanAllocVSwitchIndexAn integer index unquely identifying the vSwitch within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.2.1.1
vSwitchLPanAllocLPanIndexThe lpanIndex of the LPAN hosting the LPAN this vSwitch is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.2.1.2
vSwitchPSvrAllocTableA list of LPAN, pServer index pairs identifying pServer vSwitch allocations.
SEQUENCE OF VSwitchPSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.4.3
vSwitchPSvrAllocEntryInformation specific to each pServer vSwitch allocation.
VSwitchPSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.4.3.1
vSwitchPSvrAllocVSwitchIndexThe vSwitchIndex value of the switch that this allocation applies to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.3.1.1
vSwitchPSvrAllocLPanIndexThe lpanIndex of the LPAN hosting the pServer this vSwitch is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.3.1.2
vSwitchPSvrAllocPSvrIndexThe pServerIndex value of the pServer hosting the pServer this vSwitch is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.3.1.3
vSwtichPSvrAllocEthIndexThe pServerEthIndex value of the Eth on the pServer indicated by vSwitchPSvrAllocLPanIndex, vSwitchPSvrAllocPSvrIndex that this vSwitch is mapped to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.4.3.1.4
tapes
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.5
tapeTableA list of tape entries containing information about each tape allocated to this LPAN.
SEQUENCE OF TapeEntry
.1.3.6.1.4.1.7559.1.3.5.1
tapeEntryInformation specific to each tape in the PAN, or allocated to the LPAN if LPAN agent.
TapeEntry
.1.3.6.1.4.1.7559.1.3.5.1.1
tapeIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.5.1.1.1
tapeIdA human readable string consisting of dot separated values of HBA number, BUS ID, target device ID and LUN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.5.1.1.2
tapeMajorThe major number of this tape device.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.5.1.1.3
tapeMinorThe minor number of this tape device.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.5.1.1.4
tapeVendorA textual string identifying the tape vendor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.5.1.1.5
tapeModelA textual string identifying the tape model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.5.1.1.6
tapeSerialNumberA textual string providing the serial number of the tapero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.5.1.1.7
tapeRevThe firmare revision used by this tape.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.5.1.1.8
tapeEnabledIndicates wether the tape is enabled (true), or disabled (false).ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.5.1.1.9
tapeLPanAllocTableA list of LPAN indicies identifying LPAN tape allocations.
SEQUENCE OF TapeLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.5.2
tapeLPanAllocEntryInformation specific to each LPAN tape allocation.
TapeLPanAllocEntry
.1.3.6.1.4.1.7559.1.3.5.2.1
tapeLPanAllocIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN of the tape.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.5.2.1.1
tapeLPanAllocLPanIndexThe lpanIndex of the LPAN hosting the LPAN this tape is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.5.2.1.2
tapeLPanAllocEnabledIndicates whether the tape is currently enabled within the LPAN.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.5.2.1.3
tapePSvrAllocTableA list of LPAN, pServer index pairs identifying pServer tape allocations.
SEQUENCE OF TapePSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.5.3
tapePSvrAllocEntryInformation specific to each pServer tape allocation.
TapePSvrAllocEntry
.1.3.6.1.4.1.7559.1.3.5.3.1
tapePSvrAllocIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN of the tape.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.3.5.3.1.1
tapePSvrAllocPSvrIndexThe lpanIndex of the pServer hosting the pServer this tape is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.5.3.1.2
tapePSvrAllocLPanIndexThe lpanIndex of the LPAN hosting the pServer this tape is allocated to.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.5.3.1.3
megaREths
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.3.6
megaREthTableA list of MegaREth entries containing information about each Mega REth in the PAN. An MegaREth consists of zero or more REths, usually each on a different Frame.
SEQUENCE OF MegaREthEntry
.1.3.6.1.4.1.7559.1.3.6.1
megaREthEntryInformation specific to each rEth in the PAN.
MegaREthEntry
.1.3.6.1.4.1.7559.1.3.6.1.1
megaREthIndexAn integer value uniquely identifying the MegaREth within the PANro
INTEGER
.1.3.6.1.4.1.7559.1.3.6.1.1.1
megaREthNameA human readable string uniquely identifying the MegaREth.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.6.1.1.2
megaREthMemberTableA list of REths belonging to each MegaREth.
SEQUENCE OF MegaREthMemberEntry
.1.3.6.1.4.1.7559.1.3.6.2
megaREthMemberEntryInformation specific to each rEth in the PAN.
MegaREthMemberEntry
.1.3.6.1.4.1.7559.1.3.6.2.1
megaREthMemberMegaREthIndexAn integer value identifying the megaREthIndex value of the MegaREth containing the REth indentified by this entry.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.6.2.1.1
megaREthMemberREthIndexAn integer value identifying the rEthIndex value of the REth contained by the MegaREth indentified by this entry.ro
INTEGER
.1.3.6.1.4.1.7559.1.3.6.2.1.2
megaREthMemberREthNameA human readable string uniquely identifying the REth conainted by the MegaREth identified by this entryro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.3.6.2.1.3
lPans
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4
lPanTableA list of entries containing information and controls for LPANs.
SEQUENCE OF LPanEntry
.1.3.6.1.4.1.7559.1.4.1
lPanEntryA LPAN entry contains information and controls for LPANs.
LPanEntry
.1.3.6.1.4.1.7559.1.4.1.1
lPanIndexAn integer value uniquely identifying the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.1.1.1
lPanNameA textual string identifying the LPAN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.1.1.2
lPanHealthStatusAn indication of the health of the LPAN.ro
HealthStatusType
.1.3.6.1.4.1.7559.1.4.1.1.3
lPanUpTimeDeprecated, as of release 4.0, LPANs no longer have a concept of uptime.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.4.1.1.4
lPanControlTableA list of LPAN control entries containing controls for LPANs in the Egenera PAN.
SEQUENCE OF LPanControlEntry
.1.3.6.1.4.1.7559.1.4.2
lPanControlEntryA logical PAN entry contains controls for LPANs in the Egenera PAN.
LPanControlEntry
.1.3.6.1.4.1.7559.1.4.2.1
lPanBootWhen set to 1, invokes a boot operation on the LPAN. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.2.1.1
lPanRebootWhen set to 1, invokes a reboot operation on the LPAN. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.2.1.2
lPanDoShutdownWhen set to 1, invokes a shutdown operation on the LPAN. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.2.1.3
lPanCheckHealthWhen set to 1, invokes a checkhealth operation on the Logical PAN. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.2.1.4
lPanUpdateWhen set to 1, invokes a update operation on the LPAN. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.2.1.5
pServers
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.3
pServerTableA list of pServer entries containing information about each pServer.
SEQUENCE OF PServerEntry
.1.3.6.1.4.1.7559.1.4.3.1
pServerEntryInformation regarding each pServer.
PServerEntry
.1.3.6.1.4.1.7559.1.4.3.1.1
pServerIndexAn integer value uniquely identifying pServer within Logical PAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.1.1.1
pServerLPanIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.1.1.2
pServerBladeIndexAn integer value identifying the pBladeIndex value of the pBlade that currently hosts this pServer, -1 if no current pBlade. See pServerVBladeIndexro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.7559.1.4.3.1.1.3
pServerBladeFrameIndexAn integer value identifying the bladeFrameIndex value of the BladeFrame that hosts this pServer.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.7559.1.4.3.1.1.4
pServerNameA textual string identifying this pServer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.5
pServerFullNameA textual string fully identifying this pServer and its LPAN.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.6
pServerDescriptionA textual string describing this pServer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.7
pServerBladeFrameNameA textual string identifying the BladeFrame hosting this PServer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.8
pServerPBladeNameA textual string identifying the pBlade currently hosting this pServer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.9
pServerLPanNameA textual string identifying the LPAN containing this pServer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.10
pServerValidBootDiskThis object is deprecatedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.11
pServerHostnameThe hostname of this pServer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.12
pServerAgentAvailableIndicates whether the Egenera management agent is running on the pBlade hosting this pServer.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.13
pServerHealthStatusIndicates the health of the pServer.ro
HealthStatusType
.1.3.6.1.4.1.7559.1.4.3.1.1.14
pServerInDebuggerThis object is deprecated as of PAN Manager release 4.0. The value may be obtained via the pBlade table.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.15
pServerAutoActivateThis object is deprecated as of PAN Manager release 4.0.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.16
pServerAutoBootThis object is deprecated as of PAN Manager release 4.0.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.17
pServerActivateOrderIndicates the order within the LPAN that this pServer is activated.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.1.1.18
pServerActiveThis object is deprecated as of PAN Manager release 4.0.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.19
pServerBootStatusDescribes the boot statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.20
pServerUptimeThe length of time the pServer has been up in 1/100ths of a second.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.4.3.1.1.21
pServerFailedOverThis object is deprecated as of PAN Manager release 4.0.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.22
pServerOptionalIndicates whether this pServer has been designated as optional.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.23
pServerShutdownTimeoutThe amount of time given for the pServer to shutdown before the shutdown operation is deemed to have failed.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.1.1.24
pServerPrimaryPBladeIndexThe pBladeIndex value of the pServer's configured primary pBlade. -1 indicates none, -2 indicates global or local pool.ro
INTEGER (-2..2147483647)
.1.3.6.1.4.1.7559.1.4.3.1.1.25
pServerPrimaryPBladeFrameIndexThe bladeFrameIndex value of BladeFrame hosting the pServer's configured primary pBlade. -1 indicates none, -2 indicates global or local pool.ro
INTEGER (-2..2147483647)
.1.3.6.1.4.1.7559.1.4.3.1.1.26
pServerPrimaryPBladeNameA textual string including the Frame and pBlade name of this pServer's configured primary pBlade. 'pool' indicates global or local pool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.27
pServerFailoverPBladeIndexThe pBladeIndex value of the pServer's configured failover pBlade. -1 indicates none, -2 indicates global or local pool.ro
INTEGER (-2..2147483647)
.1.3.6.1.4.1.7559.1.4.3.1.1.28
pServerFailoverPBladeFrameIndexThe bladeFrameIndex value of BladeFrame hosting the pServer's configured failover pBlade. -1 indicates none, -2 indicates global or local pool.ro
INTEGER (-2..2147483647)
.1.3.6.1.4.1.7559.1.4.3.1.1.29
pServerFailoverPBladeNameA textual string including the Frame and pBlade name of this pServer's configured failover pBlade. 'pool' indicates global or local pool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.1.1.30
pServerVBladeIndexAn integer value identifying the vBladeIndex value of the vBlade that currently hosts this pServer, -1 if no current vBlade, or if the pServer is hosted by a pBlade. See pServerBladeIndexro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.7559.1.4.3.1.1.31
pServerStatsTableA list of pServer Monitor entries containing runtime statistics for pServers.
SEQUENCE OF PServerStatsEntry
.1.3.6.1.4.1.7559.1.4.3.2
pServerStatsEntryA pServer Monitor entry contains runtime statistics for pServers.
PServerStatsEntry
.1.3.6.1.4.1.7559.1.4.3.2.1
pServerStatsUpTimeThe uptime in 1/100ths of a second for this pServer.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.7559.1.4.3.2.1.1
pServerStatsLoadAvg1100 * the average number of jobs in the run queue over the previous minute. Returns 0 for Windows pServers.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.2
pServerStatsLoadAvg5100 * the average number of jobs in the run queue over the previous five minutes. Returns 0 for Windows pServers.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.3
pServerStatsLoadAvg15100 * the average number of jobs in the run queue over the previous fifteen minutes. Returns 0 for Windows pServers.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.4
pServerStatsCpuUserThe number of (1/100)ths of a second that the pServer spent in user mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.5
pServerStatsCpuSystemThe number of (1/100)ths of a second that the pServer spent in system mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.6
pServerStatsCpuIdleThe number of (1/100)ths of a second that the pServer spent in idle mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.7
pServerStatsLoadScaleThe load scale. Returns 0 for Windows pServers.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.8
pServerStatsNumProcsThe number of processes running on the pServer.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.9
pServerStatsLastPidThe highest allocated process ID on the pServer. Returns 0 for Windows pServers.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.2.1.10
pServerStatsContextSwitchThe number of context switches undergone by this pServer since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.11
pServerStatsInterruptThe number of interrupts encountered by this pServer since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.12
pServerStatsMemTotalThe total amount of physical RAM in kB for this pServer.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.13
pServerStatsMemFreeThe amount of free physcial RAM in kB for this pServer.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.14
pServerStatsSwapTotalThe total amount of configured swap memory in kB for this pServer.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.15
pServerStatsSwapFreeThe amount of free swap memory in kB for this pServer.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.2.1.16
pServerStatsPageInThe number of pages paged in since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.17
pServerStatsPageOutThe number of pages paged out since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.18
pServerStatsSwapInThe number of swap pages paged in since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.19
pServerStatsSwapOutThe number of swap pages paged out since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.20
pServerStatsDiskReadsThe number of disk reads since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.21
pServerStatsDiskWritesThe number of disk writes since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.22
pServerStatsDiskBlkReadsThe number of 1 kB blocks read from disk since boot. Returns 0 for Windows pServers.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.23
pServerStatsDiskBlkWritesThe number of of 1 kB blocks written to disk since boot. Returns 0 for Windows pServers.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.24
pServerStatsCpuUserNiceThe number of (1/100)ths of a second that the pServer spent in user nice mode since boot. Returns 0 for Windows pServers.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.2.1.25
pServerCpuTableA list of CPU statisitcs for each CPU on each pServer.
SEQUENCE OF PServerCpuEntry
.1.3.6.1.4.1.7559.1.4.3.3
pServerCpuEntryStatistics for each CPU on the pServer.
PServerCpuEntry
.1.3.6.1.4.1.7559.1.4.3.3.1
pServerCpuIndexAn integer uniquely identifying this CPU within the pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.3.1.1
pServerCpuPServerIndexAn integer value identifying the pServerIndex value of the pServer that hosts this CPU.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.3.1.2
pServerCpuLPanIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this CPU.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.3.1.3
pServerCpuModelNameA textual string representing the CPU model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.3.1.4
pServerCpuModelAn integer value representing the CPU model.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.3.1.5
pServerCpuFamilyAn integer value representing the CPU family.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.3.1.6
pServerCpuVendorIdA textual string representing the CPU vendor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.3.1.7
pServerCpuMhzThe speed of the CPU in Mhz.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.3.1.8
pServerCpuCacheSizeThe cache size of the CPU in MB.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.3.1.9
pServerCpuNameA textual string uniquely identifying this CPU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.3.1.10
pServerCpuUserThe number of (1/100)ths of a second that this CPU spent in user mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.3.1.11
pServerCpuUserNiceThe number of (1/100)ths of a second that this CPU spent in user nice mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.3.1.12
pServerCpuSystemThe number of (1/100)ths of a second that this CPU spent in system mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.3.1.13
pServerCpuIdleThe number of (1/100)ths of a second that this CPU spent in idle mode since boot.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.3.1.14
pServerDiskTableA list of disk statisitcs for each disk on the pServer.
SEQUENCE OF PServerDiskEntry
.1.3.6.1.4.1.7559.1.4.3.4
pServerDiskEntryDisk statisitcs for each disk on the pServer.
PServerDiskEntry
.1.3.6.1.4.1.7559.1.4.3.4.1
pServerDiskNameOctetsAn octet string representing the device special file name representing this disk.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.4.3.4.1.1
pServerDiskPServerIndexAn integer value identifying the pServerIndex value of the pServer that utilizes this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.4.1.2
pServerDiskLPanIndexAn integer value indentifying the lPanIndex value of the LPAN that hosts this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.4.1.3
pServerDiskNameThe human readable device special file name representing this disk.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.4.1.4
pServerDiskBlocksThe size of this disk in 1kB blocksro
Gauge
.1.3.6.1.4.1.7559.1.4.3.4.1.5
pServerDiskMajorThe major ID of this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.4.1.6
pServerDiskMinorThe minor ID of this disk.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.4.1.7
pServerPartitionTableA list of partition statisitcs for each partition on the pServer.
SEQUENCE OF PServerPartitionEntry
.1.3.6.1.4.1.7559.1.4.3.5
pServerPartitionEntryPartition statisitcs for each partition on the pServer.
PServerPartitionEntry
.1.3.6.1.4.1.7559.1.4.3.5.1
pServerPartitionNameOctetsAn octet string representing the device special file name representing this disk.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.4.3.5.1.1
pServerPartitionPServerIndexAn integer value identifying the pServerIndex value of the pServer that utilizes this disk partition.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.5.1.2
pServerPartitionLPanIndexAn integer value indentifying the lPanIndex value of the LPAN that hosts this partition.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.5.1.3
pServerPartitionNameA textual string identifying the device file that represents this partition.ro
DisplayString
.1.3.6.1.4.1.7559.1.4.3.5.1.4
pServerPartitionBlocksThe size of this partition in 1kB blocksro
Gauge
.1.3.6.1.4.1.7559.1.4.3.5.1.5
pServerPartitionMajorThe major ID of this partition.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.5.1.6
pServerPartitionMinorThe minor ID of this partition.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.5.1.7
pServerPartitionFSBlocksIf the partition contains a mounted filesystem, filesystem size in 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.5.1.8
pServerPartitionFSUsedBlocksIf the partition contains a mounted filesystem, the number of used 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.5.1.9
pServerPartitionFSAvailableBlocksIf the partition contains a mounted filesystem, the number of available 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.5.1.10
pServerPartitionFSUtilIf the partition contains a mounted filesystem, the number of available 1k blocks, otherwise 0.ro
Gauge
.1.3.6.1.4.1.7559.1.4.3.5.1.11
pServerEthTableInformation regarding each virtual Eth interface on a pServer.
SEQUENCE OF PServerEthEntry
.1.3.6.1.4.1.7559.1.4.3.6
pServerEthEntryInformation specific to each cBlade Eth in the PAN.
PServerEthEntry
.1.3.6.1.4.1.7559.1.4.3.6.1
pServerEthIndexAn integer uniquely identifying this interface within the pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.6.1.1
pServerEthPServerIndexAn integer value identifying the pServerIndex of the pServer that hosts this interface.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.6.1.2
pServerEthLPanIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this interface.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.6.1.3
pServerEthNameA textual string identifying the network interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.6.1.4
pServerEthMACAddressOctetsAn encoding of the eth MAC address.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.6.1.5
pServerEthMACAddressStringA human readable string representing the eth MAC address in the form: '6E:4A:1F:00:01:06'.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.3.6.1.6
pServerEthRateLimitThe configured rate limit for the pServer Eth in Mbps. 0 indicates unlimited.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.6.1.7
pServerEthStatsTableA list of interface statisitcs for each interface in the pServer.
SEQUENCE OF PServerEthStatsEntry
.1.3.6.1.4.1.7559.1.4.3.7
pServerEthStatsEntryEth statisitcs for each interface in the pServer.
PServerEthStatsEntry
.1.3.6.1.4.1.7559.1.4.3.7.1
pServerEthStatsInBytesThe number of bytes received on this interface since interface resetro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.1
pServerEthStatsInPacketsThe number of packets received on this interface since interface resetro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.2
pServerEthStatsInErrsThe number of errors received on this interface since interface resetro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.3
pServerEthStatsInDropsThe number of dropped incoming packets on this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.4
pServerEthStatsInOverrunThe number of overrun incoming packets on this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.5
pServerEthStatsInMulticastThe number of multicast packets received on this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.6
pServerEthStatsOutBytesThe number of bytes transmitted from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.7
pServerEthStatsOutPacketsThe number of packets transmitted from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.8
pServerEthStatsOutErrsThe number of errors encountered while transmitting from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.9
pServerEthStatsOutDropsThe number of dropped packets intended for transmission from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.10
pServerEthStatsOutOverrunThe number of overrun packets intended for transmission from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.11
pServerEthStatsOutCollisionsThe number of collisions detetced while transmitting from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.12
pServerEthStatsOutCarrierDctFailThe number of carrier detect failures detetced while transmitting from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.13
pServerEthStatsOutCompressedThe number of compressed packets transmitted from this interface since interface reset.ro
Counter
.1.3.6.1.4.1.7559.1.4.3.7.1.14
pServerEthStatsOperStatusThe operational state of the interface.ro
InterfaceOperStatus
.1.3.6.1.4.1.7559.1.4.3.7.1.15
pServerEthIpTableA list of IP addresses, broadcast addresses, and nework masks configured on each pServer Eth interface.
SEQUENCE OF PServerEthIpEntry
.1.3.6.1.4.1.7559.1.4.3.8
pServerEthIpEntryThe IP address, broadcast address, and network mask for a pServer Eth interface or alias.
PServerEthIpEntry
.1.3.6.1.4.1.7559.1.4.3.8.1
pServerEthIpAliasNameThe name of this network interface or alias, i.e. lo, veth31, eht10:1ro
DisplayString
.1.3.6.1.4.1.7559.1.4.3.8.1.1
pServerEthIpEthIndexAn integer value identifying the pServerEthIndex of the pServer Eth that hosts this IP configuraion.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.8.1.2
pServerEthIpPServerIndexAn integer value identifying the pServerIndex of the pServer that hosts this IP configuraion.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.8.1.3
pServerEthIpLPanIndexAn integer value identifying the lpanIndex of the LPAN that hosts this IP configuraion.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.3.8.1.4
pServerEthIpAddressThe IP address configured on this pServer eth (or alias)ro
IpAddress
.1.3.6.1.4.1.7559.1.4.3.8.1.5
pServerEthIpBroadcastThe broadcast address configured on this pServer eth (or alias)ro
IpAddress
.1.3.6.1.4.1.7559.1.4.3.8.1.6
pServerEthIpMaskThe network mask configured on this pServer eth (or alias)ro
IpAddress
.1.3.6.1.4.1.7559.1.4.3.8.1.7
pServerControlTableA list of pServer controls for each pServer.
SEQUENCE OF PServerControlEntry
.1.3.6.1.4.1.7559.1.4.3.9
pServerControlEntryControls for each pServer.
PServerControlEntry
.1.3.6.1.4.1.7559.1.4.3.9.1
pServerControlPowerUpThis object is deprecated as of PAN Manager release 4.0. This control is available via the pBladeControlTablerw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.1
pServerControlPowerDownThis object is deprecated as of PAN Manager release 4.0. This control is available via the pBladeControlTablerw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.2
pServerControlColdResetThis object is deprecated as of PAN Manager release 4.0. This control is available via the pBladeControlTablerw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.3
pServerControlWarmResetThis object is deprecated as of PAN Manager release 4.0. This control is available via the pBladeControlTablerw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.4
pServerControlNmiThis object is deprecated as of PAN Manager release 4.0. This control is available via the pBladeControlTablerw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.5
pServerBootWhen set to 1, initiates a boot operation on this pServer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.6
pServerShutdownWhen set to 1, initiates a shutdown operation on this pServer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.7
pServerForceShutdownWhen set to 1, initiates a force shutdown operation on this pServer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.8
pServerRebootWhen set to 1, initiates a reboot operation on this pServer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.9
pServerForceRebootWhen set to 1, initiates a force reboot operation on this pServer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.3.9.1.10
applications
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.4
applicationTableA list of Application entries containing information about each application configured for PAN Manager control.
SEQUENCE OF ApplicationEntry
.1.3.6.1.4.1.7559.1.4.4.1
applicationEntryInformation regarding each application.
ApplicationEntry
.1.3.6.1.4.1.7559.1.4.4.1.1
applicationIndexAn integer value uniquely identifying the application within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.1.1.1
applicationLPanIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.1.1.2
applicationNameA textual string identifying the application.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.4.1.1.3
applicationDescriptionA textual string describing the application.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.4.1.1.4
applicationStatusA textual string describing the operational status of the application.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.4.1.1.5
applicationHealthThis object is deprecatedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.4.1.1.6
appCurrentPServerIndexAn integer value identifying the pServerIndex value of the pServer currently hosting this application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.1.1.7
appPrimaryPServerIndexAn integer value identifying the pServerIndex value of the pServer configured as the application's primary pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.1.1.8
applicationControlTableA list of application entries containing controls for each application configured for PAN Manager control.
SEQUENCE OF ApplicationControlEntry
.1.3.6.1.4.1.7559.1.4.4.2
applicationControlEntryControls for each application.
ApplicationControlEntry
.1.3.6.1.4.1.7559.1.4.4.2.1
applicationStartWhen set to 1, initiates a start operation on this application. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.4.2.1.1
applicationStopWhen set to 1, initiates a stop operation on this application. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.4.2.1.2
applicationForceStopWhen set to 1, initiates a force stop operation on this application. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.4.2.1.3
applicationMoveWhen set to 1, initiates a move operation on this application. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.4.2.1.4
applicationFOPTableA list of Application failover policy assignments.
SEQUENCE OF ApplicationFOPEntry
.1.3.6.1.4.1.7559.1.4.4.3
applicationFOPEntryIndicates a failover policy to application assignment by identifying failoverPolicyIndex of the failover policy assigned to the application
ApplicationFOPEntry
.1.3.6.1.4.1.7559.1.4.4.3.1
applicationFOPIndexAn integer value identifying the failoverPolicyIndex of the failover policy mapped to the application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.3.1.1
applicationHMONTableA list of Application health monitor assignments.
SEQUENCE OF ApplicationHMONEntry
.1.3.6.1.4.1.7559.1.4.4.4
applicationHMONEntryIndicates a health monitor to application assignment by identifying healthMonitorIndex of the health monitor assigned to the application
ApplicationHMONEntry
.1.3.6.1.4.1.7559.1.4.4.4.1
applicationHMONIndexAn integer value identifying the healthMonitorIndex of the health monitor mapped to the application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.4.1.1
applicationExResTableA list of Application executable resource assignments.
SEQUENCE OF ApplicationExResEntry
.1.3.6.1.4.1.7559.1.4.4.5
applicationExResEntryIndicates a executable resource to application assignment by identifying executableResourceIndex of the executable resource assigned to the application
ApplicationExResEntry
.1.3.6.1.4.1.7559.1.4.4.5.1
applicationExResIndexAn integer value identifying the executableResourceIndex of the executable resource mapped to the application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.5.1.1
applicationSCSIResTableA list of Application SCSI disk resource assignments.
SEQUENCE OF ApplicationSCSIResEntry
.1.3.6.1.4.1.7559.1.4.4.6
applicationSCSIResEntryIndicates a SCSIRes disk resource to application assignment by identifying scsiDiskResourceIndex of the SCSI disk resource assigned to the application
ApplicationSCSIResEntry
.1.3.6.1.4.1.7559.1.4.4.6.1
applicationSCSIResIndexAn integer value identifying the scsiDiskResourceIndex of the SCSI disk resource mapped to the application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.6.1.1
applicationNFSResTableA list of Application NFS resource assignments.
SEQUENCE OF ApplicationNFSResEntry
.1.3.6.1.4.1.7559.1.4.4.7
applicationNFSResEntryIndicates an NFS resource to application assignment by identifying nfsResourceIndex of the NFS resource assigned to the application
ApplicationNFSResEntry
.1.3.6.1.4.1.7559.1.4.4.7.1
applicationNFSResIndexAn integer value identifying the nfsResourceIndex of the NFS resource mapped to the application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.7.1.1
applicationNetResTableA list of Application Network resource assignments.
SEQUENCE OF ApplicationNetResEntry
.1.3.6.1.4.1.7559.1.4.4.8
applicationNetResEntryIndicates a Network resource to application assignment by identifying networkResourceIndex of the Network resource assigned to the application
ApplicationNetResEntry
.1.3.6.1.4.1.7559.1.4.4.8.1
applicationNetResIndexAn integer value identifying the networkResourceIndex of the executable resource mapped to the application.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.4.8.1.1
loadBalancers
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.5
loadBalancerTableA list of load balancer entries containing information about each load balancer configured for PAN Manager control.
SEQUENCE OF LoadBalancerEntry
.1.3.6.1.4.1.7559.1.4.5.1
loadBalancerEntryInformation regarding each load balancer.
LoadBalancerEntry
.1.3.6.1.4.1.7559.1.4.5.1.1
loadBalancerIndexAn integer value uniquely identifying the load balancer within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.1.1.1
loadBalancerLPanIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this loadBalancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.1.1.2
loadBalancerNameA textual string identifying the load balancer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.5.1.1.3
loadBalancerDescriptionA textual string describing the load balancer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.5.1.1.4
loadBalancerStatusA textual string describing the operational status of the loadBalancer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.5.1.1.5
lbCurrentPServerIndexAn integer value identifying the pServerIndex value of the pServer currently hosting this load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.1.1.6
lbPrimaryPServerIndexAn integer value identifying the pServerIndex value of the pServer configured as the load balancer's primare pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.1.1.7
loadBalancerAutoStartA boolean value indicating whether or not the load balancer is configured for auto-start.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.5.1.1.8
loadBalancerControlTableA list of load balancer entries containing controls for each load balancer configured for PAN Manager control.
SEQUENCE OF LoadBalancerControlEntry
.1.3.6.1.4.1.7559.1.4.5.2
loadBalancerControlEntryControls for each load balancer.
LoadBalancerControlEntry
.1.3.6.1.4.1.7559.1.4.5.2.1
loadBalancerStartWhen set to 1, initiates a start operation on this load balancer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.5.2.1.1
loadBalancerStopWhen set to 1, initiates a stop operation on this load balancer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.5.2.1.2
loadBalancerForceStopWhen set to 1, initiates a force stop operation on this load balancer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.5.2.1.3
loadBalancerMoveWhen set to 1, initiates a move operation on this load balancer. When read, returns 0.rw
INTEGER
.1.3.6.1.4.1.7559.1.4.5.2.1.4
loadBalancerConnectionTableA list of configured connections to the load balancer service.
SEQUENCE OF LoadBalancerConnectionEntry
.1.3.6.1.4.1.7559.1.4.5.3
loadBalancerConnectionEntryAttributes of each load balancer connection
LoadBalancerConnectionEntry
.1.3.6.1.4.1.7559.1.4.5.3.1
loadBalancerConnectionIndexAn integer value uniquely identifying the connection within the load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.3.1.1
loadBalancerConnectionProtoIndicates the connection protocol; TCP or UDP.ro
ProtocolType
.1.3.6.1.4.1.7559.1.4.5.3.1.2
loadBalancerConnectionPortIndicates the connection port.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.3.1.3
lbConnectionStartSchedPolicyIndicates the scheduling policy for the connection. - rr-round robin (default): distribute jobs equally among available pServers. - wrr-weighted-round-robin: assign relatively more jobs to pServers with larger capacity. - lc-least-connection-assign: relatively more jobs to pServers with fewer scheduled jobs. - wlc-weighted-least-connected: assign relatively more jobs to pServers with less scheduled jobs relative to their capacity.ro
SchedulePolicyType
.1.3.6.1.4.1.7559.1.4.5.3.1.4
loadBalancerPersistConnectionIndicates the whether or not established connections from clients should always be serviced by the same load balancer member.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.5.3.1.5
loadBalancerMemberTableA list of applications that are members of the load balancer service.
SEQUENCE OF LoadBalancerMemberEntry
.1.3.6.1.4.1.7559.1.4.5.4
loadBalancerMemberEntryAttributes of each application that is a member of the load balancer service.
LoadBalancerMemberEntry
.1.3.6.1.4.1.7559.1.4.5.4.1
loadBalancerMemberIndexAn integer value identifying the applicationIndex value of the application that is a member of this load balancer service.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.4.1.1
loadBalancerMemberWeightAn integer value identifying the weight criteria for the member, a member with weight 2 will handle twice the load as a member of weight 1.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.4.1.2
lbMemberStartWithServiceIndicates whether or not this member is configured to start when the load balancer service is started.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.5.4.1.3
loadBalancerFOPTableA list of load balancer failover policy assignments.
SEQUENCE OF LoadBalancerFOPEntry
.1.3.6.1.4.1.7559.1.4.5.5
loadBalancerFOPEntryIndicates a failover policy to load balancer assignment by identifying failoverPolicyIndex of the failover policy assigned to the load balancer
LoadBalancerFOPEntry
.1.3.6.1.4.1.7559.1.4.5.5.1
loadBalancerFOPIndexAn integer value identifying the failoverPolicyIndex of the failover policy mapped to the load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.5.1.1
loadBalancerHMONTableA list of load balancer health monitor assignments.
SEQUENCE OF LoadBalancerHMONEntry
.1.3.6.1.4.1.7559.1.4.5.6
loadBalancerHMONEntryIndicates a health monitor to load balancer assignment by identifying healthMonitorIndex of the health monitor assigned to the load balancer
LoadBalancerHMONEntry
.1.3.6.1.4.1.7559.1.4.5.6.1
loadBalancerHMONIndexAn integer value identifying the healthMonitorIndex of the health monitor mapped to the load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.6.1.1
loadBalancerExResTableA list of load balancer executable resource assignments.
SEQUENCE OF LoadBalancerExResEntry
.1.3.6.1.4.1.7559.1.4.5.7
loadBalancerExResEntryIndicates a executable resource to load balancer assignment by identifying executableResourceIndex of the executable resource assigned to the load balancer
LoadBalancerExResEntry
.1.3.6.1.4.1.7559.1.4.5.7.1
loadBalancerExResIndexAn integer value identifying the executableResourceIndex of the executable resource mapped to the load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.7.1.1
loadBalancerSCSIResTableA list of load balancer SCSI disk resource assignments.
SEQUENCE OF LoadBalancerSCSIResEntry
.1.3.6.1.4.1.7559.1.4.5.8
loadBalancerSCSIResEntryIndicates a SCSIRes disk resource to load balancer assignment by identifying scsiDiskResourceIndex of the SCSI disk resource assigned to the load balancer
LoadBalancerSCSIResEntry
.1.3.6.1.4.1.7559.1.4.5.8.1
loadBalancerSCSIResIndexAn integer value identifying the scsiDiskResourceIndex of the SCSI disk resource mapped to the load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.8.1.1
loadBalancerNFSResTableA list of load balancer NFS resource assignments.
SEQUENCE OF LoadBalancerNFSResEntry
.1.3.6.1.4.1.7559.1.4.5.9
loadBalancerNFSResEntryIndicates an NFS resource to load balancer assignment by identifying nfsResourceIndex of the NFS resource assigned to the load balancer
LoadBalancerNFSResEntry
.1.3.6.1.4.1.7559.1.4.5.9.1
loadBalancerNFSResIndexAn integer value identifying the nfsResourceIndex of the NFS resource mapped to the load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.9.1.1
loadBalancerNetResTableA list of load balancer Network resource assignments.
SEQUENCE OF LoadBalancerNetResEntry
.1.3.6.1.4.1.7559.1.4.5.10
loadBalancerNetResEntryIndicates a Network resource to load balancer assignment by identifying networkResourceIndex of the Network resource assigned to the load balancer
LoadBalancerNetResEntry
.1.3.6.1.4.1.7559.1.4.5.10.1
loadBalancerNetResIndexAn integer value identifying the networkResourceIndex of the executable resource mapped to the load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.5.10.1.1
applicationResources
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.6
failoverPolicies
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.6.1
failoverPolicyTableA list of entries describing failover policies.
SEQUENCE OF FailoverPolicyEntry
.1.3.6.1.4.1.7559.1.4.6.1.1
failoverPolicyEntryA list of attributes describing a failover policy
FailoverPolicyEntry
.1.3.6.1.4.1.7559.1.4.6.1.1.1
failoverPolicyIndexAn integer value identifying the failover policy within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.1.1.1.1
failoverPolicyLPANIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this failover policy.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.1.1.1.2
failoverPolicyNameA textual String identifying the failover policy.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.1.1.1.3
failoverPolicyDescriptionA textual string describing the failover policy.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.1.1.1.4
failoverPolicySelectionPolicyIndicates the selection policy used by the failover policy to determine the next pServer to host the application or load balancer.ro
FOPSelectionPolicyType
.1.3.6.1.4.1.7559.1.4.6.1.1.1.5
failoverPolicyAutoFailbackIndicates whether or not the failover policy is configured for auto-failbackro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.1.1.1.6
failoverPolicyRebootPServerIndicates wether or not the pServer failed over from should be rebootedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.1.1.1.7
failoverPolicyPServerTableA list of entries describing failover policy member pServers.
SEQUENCE OF FailoverPolicyPServerEntry
.1.3.6.1.4.1.7559.1.4.6.1.2
failoverPolicyPServerEntryA list of attributes describing each failover policy pServer member
FailoverPolicyPServerEntry
.1.3.6.1.4.1.7559.1.4.6.1.2.1
failoverPolicyPServerIndexAn integer value identifying the pServerIndex value of the pServer member of this failover policy.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.1.2.1.1
failoverPolicyPServerOrderAn integer value identifying the activation order of this pServer within the failover policy.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.1.2.1.2
healthMonitors
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.6.2
healthMonitorTableA list of entries describing application/load balancer health monitors.
SEQUENCE OF HealthMonitorEntry
.1.3.6.1.4.1.7559.1.4.6.2.1
healthMonitorEntryA list of attributes describing a failover policy
HealthMonitorEntry
.1.3.6.1.4.1.7559.1.4.6.2.1.1
healthMonitorIndexAn integer value identifying the health monitor within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.1.1.1
healthMonitorLPANIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this health monitor.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.1.1.2
healthMonitorNameA textual string identifying the health monitor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.2.1.1.3
healthMonitorDescriptionA textual string describing the health monitor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.2.1.1.4
healthMonitorScriptThe health monitor script (and arguments) used to test the health of the application.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.2.1.1.5
healthMonitorRestartPolicyIndicates whether any health monitor or all health monitors must reach the configured threshold before a restart is invoked.ro
HealthMonPolicyType
.1.3.6.1.4.1.7559.1.4.6.2.1.1.6
healthMonitorRestartThresholdThe number of consecutive health monitor detected failures required before a restart is invoked on the monitored application or load balancerro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.1.1.7
healthMonitorFailoverPolicyIndicates whether any health monitor or all health monitors must reach the configured threshold before a failover is invoked.ro
HealthMonPolicyType
.1.3.6.1.4.1.7559.1.4.6.2.1.1.8
healthMonitorFailoverThresholdThe number of consecutive health monitor detected failures required before a failover is invoked on the monitored application or load balancerro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.1.1.9
healthMonitorGiveupPolicyIndicates whether any health monitor or all health monitors must reach the configured threshold before a give-up occurs.ro
HealthMonPolicyType
.1.3.6.1.4.1.7559.1.4.6.2.1.1.10
healthMonitorGiveupThresholdThe number of consecutive health monitor detected failures required before a givup occurs for the monitored application or load balancerro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.1.1.11
healthMonitorPServerTableA list of entries describing pServers that host this health monitor.
SEQUENCE OF HealthMonitorPServerEntry
.1.3.6.1.4.1.7559.1.4.6.2.2
healthMonitorPServerEntryA list of attributes describing a health monitor host pServer.
HealthMonitorPServerEntry
.1.3.6.1.4.1.7559.1.4.6.2.2.1
healthMonitorPServerIndexAn integer value identifying the pServerIndex value of the pServer that hosts this health monitor. The value 999 is used to identify the 'local' pServer. If local settings are configured, the health monitor will use these settings whenever the monitor and the monitored application or load balancer are hosted by the same pServer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.2.1.1
healthMonitorIntervalThe polling frequency in seconds that this monitor test an application or loadbalancer health.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.2.1.2
healthMonitorStartupDelayThe startup dely in seconds that this monitor waits after application or loadbalancer start before the monitor begins checking the health of the application or load balancer.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.2.2.1.3
executableResources
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.6.3
executableResourceTableA list of entries describing application/load balancer executable resources.
SEQUENCE OF ExecutableResourceEntry
.1.3.6.1.4.1.7559.1.4.6.3.1
executableResourceEntryA list of attributes describing an executable resource.
ExecutableResourceEntry
.1.3.6.1.4.1.7559.1.4.6.3.1.1
executableResourceIndexAn integer value identifying the executable resource within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.3.1.1.1
executableResourceLPANIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this executable resource.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.3.1.1.2
executableResourceNameA textual string identifying the executable resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.3.1.1.3
executableResourceDescriptionA textual string describing the executable resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.3.1.1.4
executableResourceUserA textual string identifying the user that will execute the resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.3.1.1.5
executableResourceCommandA textual string identifying the command used to start, stop, or execute the application or resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.3.1.1.6
executableResourceStartArgsA textual string identifying the arguments passed to the command when starting an application or resoruce.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.3.1.1.7
executableResourceStopArgsA textual string identifying the arguments passed to the command when stopping an application or resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.3.1.1.8
executableResourceExecuteArgsA textual string identifying the arguments passed to the command when executing an application or resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.3.1.1.9
scsiDiskResources
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.6.4
scsiDiskResourceTableA list of entries describing SCSI disk resources.
SEQUENCE OF ScsiDiskResourceEntry
.1.3.6.1.4.1.7559.1.4.6.4.1
scsiDiskResourceEntryA list of attributes describing each SCSI disk resource.
ScsiDiskResourceEntry
.1.3.6.1.4.1.7559.1.4.6.4.1.1
scsiDiskResourceIndexAn integer value identifying the SCSI disk resource within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.4.1.1.1
scsiDiskResourceLPANIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this SCSI disk resource.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.4.1.1.2
scsiDiskResourceNameA textual string identifying the SCSI disk resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.1.1.3
scsiDiskResourceDescriptionA textual string describing the SCSI disk resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.1.1.4
scsiDiskResourceDiskIdA human readable string consisting of dot separated values of HBA number, BUS ID, target device ID and LUN of the SCSI disk contained in this resource. 0.0.0.0 indicates an unconfigured disk.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.1.1.5
scsiDiskResourceDiskIdOctetsA sequence of 4 bytes encoding the values of HBA number, BUS ID, target device ID and LUN of the SCSI disk contained in this resource. 0.0.0.0 indicates an unconfigured disk.ro
OCTET STRING
.1.3.6.1.4.1.7559.1.4.6.4.1.1.6
scsiDiskResMountPtTableA list of entries describing SCSI disk resources mount points.
SEQUENCE OF ScsiDiskResMountPtEntry
.1.3.6.1.4.1.7559.1.4.6.4.2
scsiDiskResMountPtEntryA list of attributes describing each SCSI disk resource mount point
ScsiDiskResMountPtEntry
.1.3.6.1.4.1.7559.1.4.6.4.2.1
scsiDiskResMountPtIndexAn integer value identifying the SCSI disk resource mount point within the SCSI disk resource.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.4.2.1.1
scsiDiskResMountPtNameThe path name of the mount pointro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.2.1.2
scsiDiskResMountPtPartitionAn integer value identifying the partition number on the SCSI disk containing the file system to be mounted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.2.1.3
scsiDiskResMountPtAccessModeIndicates whether the file system is mounted read-only or read-write.ro
AccessMode
.1.3.6.1.4.1.7559.1.4.6.4.2.1.4
scsiDiskResMountPtCreateMountIndicates whether or not the mount point should be created if it does not exist.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.2.1.5
scsiDiskResMountPtScanDiskIndicates whether or not the disk should be scanned prior to mounting.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.2.1.6
scsiDiskResMountPtOrderIndicates the order in which the file system should be mounted. 0 indicates unordered mounting.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.4.2.1.7
scsiDiskResMountPtMountOptionIndicates any options to be used when mounting the filesystem.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.4.2.1.8
nfsResources
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.6.5
nfsResourceTableA list of entries describing NFS resources.
SEQUENCE OF NfsResourceEntry
.1.3.6.1.4.1.7559.1.4.6.5.1
nfsResourceEntryA list of attributes describing each NFS resource.
NfsResourceEntry
.1.3.6.1.4.1.7559.1.4.6.5.1.1
nfsResourceIndexAn integer value identifying the NFS resource resource within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.5.1.1.1
nfsResourceLPANIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this NFS resource.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.5.1.1.2
nfsResourceNameA textual string identifying the NFS resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.3
nfsResourceDescriptionA textual string describing the NFS resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.4
nfsResourceHostNameA textual string identifying the host name (or IP address) that hosts this resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.5
nfsResourceHostFileSystemThe path name of the exported NFS filesystem.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.7
nfsResourceAccessModeIndicates whether the NFS filesystem is mounted read-only or read-write.ro
AccessMode
.1.3.6.1.4.1.7559.1.4.6.5.1.1.8
nfsResourceUserA textual string identifying the user that will mount the NFS resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.9
nfsResourceMountPointThe path of the mount point for the NFS resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.10
nfsResourceCreateMountPtIndicates whether or not the mount point should be created if it doesn't already exist.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.11
nfsResourceMountOptionIndicates any options to be used when mounting the NFS resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.5.1.1.12
networkResources
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.4.6.6
networkResourceTableA list of entries describing NFS resources.
SEQUENCE OF NetworkResourceEntry
.1.3.6.1.4.1.7559.1.4.6.6.1
networkResourceEntryA list of attributes describing each NFS resource.
NetworkResourceEntry
.1.3.6.1.4.1.7559.1.4.6.6.1.1
networkResourceIndexAn integer value identifying the network resource within the LPAN.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.6.1.1.1
networkResourceLPANIndexAn integer value identifying the lPanIndex value of the LPAN that hosts this network resource.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.6.1.1.2
networkResourceNameA textual string identifying the network resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.6.1.1.3
networkResourceDescriptionA textual string describing the network resource.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.6.1.1.4
networkResourceTypeIndicates whether the network resource is assigned to a specific vEth or to a specific vSwitch.ro
NetworkResourceType
.1.3.6.1.4.1.7559.1.4.6.6.1.1.5
networkResourceMACAddressOctetsAn encoding of the network resource MAC address.ro
PhysAddress (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.6.1.1.6
networkResourceMACAddressStringA human readable string representing the newtork resource MAC address in the form: '6E:4A:1F:00:01:06'.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.4.6.6.1.1.7
networkResourceRateLimitThe configured rate limit for the network resource in Mbps, 0 indicates none or not applicable.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.6.1.1.8
networkResourceIPTableA list of IP entries associated with each network resource.
SEQUENCE OF NetworkResourceIPEntry
.1.3.6.1.4.1.7559.1.4.6.6.2
networkResourceIPEntryA list of attributes describing IP addresses associated with each network resource.
NetworkResourceIPEntry
.1.3.6.1.4.1.7559.1.4.6.6.2.1
networkResourceIPIndexAn integer value identifying the network resource IP address within the network resource.ro
INTEGER
.1.3.6.1.4.1.7559.1.4.6.6.2.1.1
networkResourceIPAddressThe IP address configured on this network resourcero
IpAddress
.1.3.6.1.4.1.7559.1.4.6.6.2.1.2
networkResourceIPBroadcastThe broadcast address configured on this network resource)ro
IpAddress
.1.3.6.1.4.1.7559.1.4.6.6.2.1.3
networkResourceIPMaskThe network mask configured on this network resourcero
IpAddress
.1.3.6.1.4.1.7559.1.4.6.6.2.1.4
pools
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.5
poolTableA list of entries containing information for Global Pools and Local Pools.
SEQUENCE OF PoolEntry
.1.3.6.1.4.1.7559.1.5.1
poolEntryA Pool entry contains information for Global Pools and Local Pools.
PoolEntry
.1.3.6.1.4.1.7559.1.5.1.1
poolIndexAn integer value uniquely identifying the pool.ro
INTEGER
.1.3.6.1.4.1.7559.1.5.1.1.1
poolNameA textual string identifying the pool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.5.1.1.2
poolDescriptionA textual string describing the pool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.5.1.1.3
poolLinkedIndexFor local pools, the poolIndex of the global pool that the local pool is linked to, or -1 if not linked. For Global Pools, this value is -1.ro
INTEGER
.1.3.6.1.4.1.7559.1.5.1.1.4
poolTypeIndicates the type of pool (global or local).ro
PoolType
.1.3.6.1.4.1.7559.1.5.1.1.5
poolAvailableBladesIndicates the number of blades currently available in the pool.ro
INTEGER
.1.3.6.1.4.1.7559.1.5.1.1.6
egeneraNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1000
egeneraNotificationObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.1.1000.1
egeneraTrapSeverityAn integer variable identifying trap severity. This value is set and packaged in every notification or trap sent.ro
INTEGER
.1.3.6.1.4.1.7559.1.1000.1.1
egeneraTrapMessageAn string containing a message associated with each trap. This value is set and packaged in every notification or trap sent.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1000.1.2
snmpManagerAddressA string containing the source IP address of illegal SNMP requests.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1000.1.3
sensorNameThe textual name of the hardware sensor contained in pBlade, cBlade and sBlade voltage, temperature, and fanspeed hardware sensor threshold eventsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1000.1.6
sensorThresholdThe integer representation of the hardware threshold exceeded contained in hardware sensor threshold events. Voltage values are multiplied by 100 and rounded to convert from float to integer, thus 2.98 => 298ro
INTEGER
.1.3.6.1.4.1.7559.1.1000.1.7
sensorValueThe integer representation of the hardware sensor value contained in hardware sensor threshold events. Voltage values are multiplied by 100 and rounted to convert from float to integer. Thus 0.530 => 53ro
INTEGER
.1.3.6.1.4.1.7559.1.1000.1.8
monitorNameThe textual name of User Defined Monitor driving pServerUserMonitorTraps.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1000.1.9
ruleNameThe textual name of User Defined Monitor Rule that was matched that drives pServerUserMonitorTraps.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.7559.1.1000.1.10
thirdParty
OBJECT IDENTIFIER
.1.3.6.1.4.1.7559.100