Home/Catalog/EATON-EPDU-PU-SW-MIB

EATON-EPDU-PU-SW-MIB

AI MIB Summary

The EATON-EPDU-PU-SW-MIB enables SNMP-based monitoring and control of Eaton Switched Enclosed Power Distribution Units, specifically exposing switch port status, power outlet states, and circuit breaker configurations for remote power management.

The MIB module for Eaton Switched ePDUs (Enclosed Power Distribution Units.)
Main OID:
pulizzi.1.3.6.1.4.1.20677
517
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

517 total
Object Name
pulizziThe MIB module for Eaton Switched ePDUs (Enclosed Power Distribution Units.)
MODULE-IDENTITY
.1.3.6.1.4.1.20677
ipv3600
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2
unitConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.1
unitNameDescriptive name of unit.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.1.1
strappingIdID of unit when connected in a strapping configuration.ro
Integer32
.1.3.6.1.4.1.20677.2.1.2
unitTimeTime hh:mmrw
OCTET STRING
.1.3.6.1.4.1.20677.2.1.3
unitDateToday's date mm/dd/yyyyrw
OCTET STRING
.1.3.6.1.4.1.20677.2.1.4
unitDayOfWeekToday's day of week. This is important when scheduling logs to be sent on a particular week day.rw
Enumeration
.1.3.6.1.4.1.20677.2.1.5
vaLoggingIntervalInterval for updating the VA log.rw
Enumeration
.1.3.6.1.4.1.20677.2.1.6
loginTimeoutTimeout (in seconds) for serial, telnet, and web interfaces.rw
Integer32
.1.3.6.1.4.1.20677.2.1.7
invertDisplaySelect the orientation of the local 7-segment display.rw
Enumeration
.1.3.6.1.4.1.20677.2.1.8
fahrenheitOrCelsiusUnits for temperature readings.rw
Enumeration
.1.3.6.1.4.1.20677.2.1.9
networkSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.2
unitIPAddressNetwork IP addressro
IpAddress
.1.3.6.1.4.1.20677.2.2.1
subnetMaskNetwork subnet maskro
IpAddress
.1.3.6.1.4.1.20677.2.2.2
defaultGatewayNetwork default gatewayro
IpAddress
.1.3.6.1.4.1.20677.2.2.3
webPortPort number for non-secure (http) web interface.rw
Integer32
.1.3.6.1.4.1.20677.2.2.4
webEnabledEnables or disables the web interface (both secure and non-secure).rw
Enumeration
.1.3.6.1.4.1.20677.2.2.5
macAddressHardware network addressro
OCTET STRING
.1.3.6.1.4.1.20677.2.2.6
enablePingEnables ping watchdog feature. If enabled, the IP address for each outlet (if non-zero) will be pinged periodically; the outlet will be rebooted if there is no ping response.rw
Enumeration
.1.3.6.1.4.1.20677.2.2.7
pingIntervalInterval (in minutes) beween attempts to ping the IP address corresponding to an outlet.rw
Integer32
.1.3.6.1.4.1.20677.2.2.8
logManagerConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.3
mailServerIPAddressIP address of mail server for sending logs and alerts.rw
IpAddress
.1.3.6.1.4.1.20677.2.3.1
sendLogFromEmail address (x@y.z format) to be used as the from address for logs and alerts.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.3.2
sendLogToUser1AddressEmail address to which to send unit logs.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.3.3
sendLogToUser2AddressSecond email address to which to send unit logs.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.3.4
sendAlertsToUser1AddressEmail address to which to send unit alerts.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.3.5
sendAlertsToUser2AddressSecond email address to which to send unit alerts.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.3.6
sendLogFrequencyFrequency with which to send logs via email.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.7
sendLogTimeTime of day to send logs via email. Not applicable if sendLogFrequency is set to whenFull or never.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.3.8
userLogInLogOutEnabled setting to log or send an alert when a user logs in or logs out of the serial, telnet, or web interfaces.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.9
userLogInLogOutFailedEnabled setting to log or send an alert when a user attempts to log in but fails because of a username or password mismatch.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.10
outletActivityEnabled setting to log or send an alert each time an outlet changes state.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.11
systemOnOffEnabled setting to log or send an alert each time the unit powers up.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.12
outletSection1AlertEnabled setting to send an email alert when section 1 thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.13
outletSection2AlertEnabled setting to send an email alert when section 2 thresholds are brached.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.14
outletSection3AlertEnabled setting to send an email alert when section 3 thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.15
tempSensor1AlertEnabled setting to send an email alert when temperature sensor 1 thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.16
tempSensor2AlertEnabled setting to send an email alert when temperature sensor 2 thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.17
humSensor1AlertEnabled setting to send an email alert when humidity sensor thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.18
contactClosure1AlertEnabled setting to send an email alert when contact sensor 1 changes state.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.19
contactClosure2AlertEnabled setting to send an email alert when contact sensor 2 changes state.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.20
contactClosure3AlertEnabled setting to send an email alert when contact sensor 3 changes state.rw
Enumeration
.1.3.6.1.4.1.20677.2.3.21
serialSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.4
baudRateSerial baud rate, does not take effect unless unit is soft-rebooted.rw
Enumeration
.1.3.6.1.4.1.20677.2.4.1
telnetSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.5
telnetPortTelnet interface port, default is 23.rw
Integer32
.1.3.6.1.4.1.20677.2.5.1
telnetEnabledEnabled setting for the telnet interface. This can be disabled for security.rw
Enumeration
.1.3.6.1.4.1.20677.2.5.2
outletMngt
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6
outletConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1
outlet1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.1
outlet1NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.1.1
outlet1PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.1.2
outlet1SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.1.4
outlet1RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.1.5
outlet2
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.2
outlet2NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.2.1
outlet2PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.2.2
outlet2SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.2.4
outlet2RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.2.5
outlet3
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.3
outlet3NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.3.1
outlet3PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.3.2
outlet3SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.3.4
outlet3RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.3.5
outlet4
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.4
outlet4NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.4.1
outlet4PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.4.2
outlet4SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.4.4
outlet4RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.4.5
outlet5
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.5
outlet5NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.5.1
outlet5PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.5.2
outlet5SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.5.4
outlet5RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.5.5
outlet6
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.6
outlet6NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.6.1
outlet6PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.6.2
outlet6SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.6.4
outlet6RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.6.5
outlet7
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.7
outlet7NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.7.1
outlet7PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.7.2
outlet7SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.7.4
outlet7RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.7.5
outlet8
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.8
outlet8NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.8.1
outlet8PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.8.2
outlet8SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.8.4
outlet8RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.8.5
outlet9
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.9
outlet9NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.9.1
outlet9PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.9.2
outlet9SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.9.4
outlet9RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.9.5
outlet10
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.10
outlet10NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.10.1
outlet10PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.10.2
outlet10SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.10.4
outlet10RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.10.5
outlet11
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.11
outlet11NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.11.1
outlet11PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.11.2
outlet11SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.11.4
outlet11RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.11.5
outlet12
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.12
outlet12NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.12.1
outlet12PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.12.2
outlet12SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.12.4
outlet12RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.12.5
outlet13
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.13
outlet13NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.13.1
outlet13PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.13.2
outlet13SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.13.4
outlet13RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.13.5
outlet14
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.14
outlet14NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.14.1
outlet14PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.14.2
outlet14SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.14.4
outlet14RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.14.5
outlet15
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.15
outlet15NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.15.1
outlet15PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.15.2
outlet15SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.15.4
outlet15RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.15.5
outlet16
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.16
outlet16NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.16.1
outlet16PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.16.2
outlet16SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.16.4
outlet16RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.16.5
outlet17
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.17
outlet17NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.17.1
outlet17PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.17.2
outlet17SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.17.4
outlet17RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.17.5
outlet18
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.18
outlet18NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.18.1
outlet18PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.18.2
outlet18SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.18.4
outlet18RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.18.5
outlet19
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.19
outlet19NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.19.1
outlet19PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.19.2
outlet19SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.19.4
outlet19RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.19.5
outlet20
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.20
outlet20NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.20.1
outlet20PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.20.2
outlet20SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.20.4
outlet20RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.20.5
outlet21
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.21
outlet21NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.21.1
outlet21PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.21.2
outlet21SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.21.4
outlet21RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.21.5
outlet22
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.22
outlet22NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.22.1
outlet22PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.22.2
outlet22SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.22.4
outlet22RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.22.5
outlet23
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.23
outlet23NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.23.1
outlet23PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.23.2
outlet23SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.23.4
outlet23RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.23.5
outlet24
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.24
outlet24NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.24.1
outlet24PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.24.2
outlet24SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.24.4
outlet24RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.24.5
outlet25
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.25
outlet25NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.25.1
outlet25PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.25.2
outlet25SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.25.4
outlet25RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.25.5
outlet26
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.26
outlet26NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.26.1
outlet26PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.26.2
outlet26SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.26.4
outlet26RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.26.5
outlet27
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.27
outlet27NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.27.1
outlet27PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.27.2
outlet27SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.27.4
outlet27RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.27.5
outlet28
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.28
outlet28NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.28.1
outlet28PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.28.2
outlet28SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.28.4
outlet28RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.28.5
outlet29
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.29
outlet29NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.29.1
outlet29PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.29.2
outlet29SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.29.4
outlet29RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.29.5
outlet30
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.30
outlet30NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.30.1
outlet30PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.30.2
outlet30SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.30.4
outlet30RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.30.5
outlet31
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.31
outlet31NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.31.1
outlet31PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.31.2
outlet31SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.31.4
outlet31RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.31.5
outlet32
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.32
outlet32NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.32.1
outlet32PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.32.2
outlet32SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.32.4
outlet32RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.32.5
outlet33
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.33
outlet33NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.33.1
outlet33PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.33.2
outlet33SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.33.4
outlet33RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.33.5
outlet34
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.34
outlet34NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.34.1
outlet34PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.34.2
outlet34SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.34.4
outlet34RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.34.5
outlet35
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.35
outlet35NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.35.1
outlet35PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.35.2
outlet35SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.35.4
outlet35RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.35.5
outlet36
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.1.36
outlet36NameDescriptive outlet namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.6.1.36.1
outlet36PingIpAddressPing watchdog IP addressrw
IpAddress
.1.3.6.1.4.1.20677.2.6.1.36.2
outlet36SequenceTimeTime in seconds for the outlet to delay turning on after a Sequence On command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.36.4
outlet36RebootTimeTime in seconds for the outlet to remain off when a Reboot command is issued.rw
Integer32
.1.3.6.1.4.1.20677.2.6.1.36.5
outletControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.2
globalCommandIssue a command to all outlets on this unit.rw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.1
outlet1CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.2
outlet2CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.3
outlet3CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.4
outlet4CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.5
outlet5CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.6
outlet6CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.7
outlet7CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.8
outlet8CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.9
outlet9CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.10
outlet10CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.11
outlet11CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.12
outlet12CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.13
outlet13CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.14
outlet14CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.15
outlet15CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.16
outlet16CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.17
outlet17CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.18
outlet18CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.19
outlet19CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.20
outlet20CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.21
outlet21CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.22
outlet22CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.23
outlet23CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.24
outlet24CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.25
outlet25CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.26
outlet26CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.27
outlet27CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.28
outlet28CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.29
outlet29CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.30
outlet30CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.31
outlet31CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.32
outlet32CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.33
outlet33CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.34
outlet34CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.35
outlet35CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.36
outlet36CommandIssue an outlet commandrw
Enumeration
.1.3.6.1.4.1.20677.2.6.2.37
outletStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.6.3
outlet1StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.1
outlet2StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.2
outlet3StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.3
outlet4StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.4
outlet5StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.5
outlet6StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.6
outlet7StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.7
outlet8StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.8
outlet9StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.9
outlet10StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.10
outlet11StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.11
outlet12StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.12
outlet13StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.13
outlet14StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.14
outlet15StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.15
outlet16StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.16
outlet17StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.17
outlet18StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.18
outlet19StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.19
outlet20StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.20
outlet21StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.21
outlet22StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.22
outlet23StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.23
outlet24StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.24
outlet25StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.25
outlet26StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.26
outlet27StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.27
outlet28StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.28
outlet29StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.29
outlet30StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.30
outlet31StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.31
outlet32StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.32
outlet33StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.33
outlet34StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.34
outlet35StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.35
outlet36StatusGet the outlet statusro
Enumeration
.1.3.6.1.4.1.20677.2.6.3.36
snmpSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.7
publicCommunityNameEnter the read-only community name. Default publicobsolete
OCTET STRING
.1.3.6.1.4.1.20677.2.7.1
privateCommunityNameEnter the read-write community name. Default privateobsolete
OCTET STRING
.1.3.6.1.4.1.20677.2.7.2
trapCommunityNameEnter the Trap community name. Default publicobsolete
OCTET STRING
.1.3.6.1.4.1.20677.2.7.3
publicCommunityPasswordEnter the read-only community password. Default publicobsolete
OCTET STRING
.1.3.6.1.4.1.20677.2.7.4
privateCommunityPasswordEnter the read-write community password. Default privateobsolete
OCTET STRING
.1.3.6.1.4.1.20677.2.7.5
trapIpAddressEnter the IP address to which to send SNMP traps.rw
IpAddress
.1.3.6.1.4.1.20677.2.7.6
snmpEnabledEnabled setting for SNMP interfaceobsolete
Enumeration
.1.3.6.1.4.1.20677.2.7.7
snmpTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.7.8
trapUserLoginLogoutEnabled setting to send an SNMP trap when a user logs in/out of the serial, telnet, or web interfaces.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.1
trapFailedLoginEnabled setting to send an SNMP trap when a user fails to log into the serial, telnet, or web interfaces because of a username or password mismatch.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.2
trapOutletActivityEnabled setting to send an SNMP trap whenever an outlet changes state.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.3
trapSystemOnOffEnabled setting to send an SNMP trap when the PDU powers up.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.4
trapOutletSection1ThresholdEnabled setting to send an SNMP trap when the section 1 thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.5
trapOutletSection2ThresholdEnabled setting to send an SNMP trap when the section 2 thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.6
trapOutletSection3ThresholdEnabled setting to send an SNMP trap when the section 3 thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.7
trapTemperatureSensor1ThresholdEnabled setting to send an SNMP trap when the temperature 1 sensor thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.8
trapTemperatureSensor2ThresholdEnabled setting to send an SNMP trap when the temperature 2 sensor thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.9
trapHumiditySensorThresholdEnabled setting to send an SNMP trap when the humidity sensor thresholds are breached.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.10
trapContactClosure1ThresholdEnabled setting to send an SNMP trap when the contact sensor 1 state changes.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.11
trapContactClosure2ThresholdEnabled setting to send an SNMP trap when the contact sensor 2 state changes.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.12
trapContactClosure3ThresholdEnabled setting to send an SNMP trap when the contact sensor 3 state changes.rw
Enumeration
.1.3.6.1.4.1.20677.2.7.8.13
environmentalSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8
temperatureSensorConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.1
tempSensor1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.1.1
tempSensor1NameDescriptive sensor namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.1.1.1
tempSensor1EnableWhen disabled, the sensor measurement is not displayed and the thresholds are ignored.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.1.1.2
tempSensor1HighThreshSensor high thresholdrw
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.8.1.1.3
tempSensor1LowThreshSensor low thresholdrw
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.8.1.1.4
tempSensor1ControlOutletEnabled setting to control an outlet or group based on the sensor thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.1.1.5
tempSensor1OutletNameOutlet or group name to control based on the sensor measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.1.1.6
tempSensor1OutletStateturnOutletOn setting will turn the outlet/group on when the thresholds are breached and off when between the thresholds. turnOutletOff setting will turn the outlet/group off when the thresholds are breached and on when between the thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.1.1.7
tempSensor2
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.1.2
tempSensor2NameDescriptive sensor namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.1.2.1
tempSensor2EnableWhen disabled, the sensor measurement is not displayed and the thresholds are ignored.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.1.2.2
tempSensor2HighThreshSensor high thresholdrw
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.8.1.2.3
tempSensor2LowThreshSensor low thresholdrw
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.8.1.2.4
tempSensor2ControlOutletEnabled setting to control an outlet or group based on the sensor thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.1.2.5
tempSensor2OutletNameOutlet or group name to control based on the sensor measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.1.2.6
tempSensor2OutletStateturnOutletOn setting will turn the outlet/group on when the thresholds are breached and off when between the thresholds. turnOutletOff setting will turn the outlet/group off when the thresholds are breached and on when between the thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.1.2.7
humiditySensorConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.2
humSensor1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.2.1
humSensor1NameDescriptive sensor namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.2.1.1
humSensor1EnableWhen disabled, the sensor measurement is not displayed and the thresholds are ignored.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.2.1.2
humSensor1HighThreshSensor high thresholdrw
Integer32
.1.3.6.1.4.1.20677.2.8.2.1.3
humSensor1LowThreshSensor low thresholdrw
Integer32
.1.3.6.1.4.1.20677.2.8.2.1.4
humSensor1ControlOutletEnabled setting to control an outlet or group based on the sensor thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.2.1.5
humSensor1OutletNameOutlet or group name to control based on the sensor measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.2.1.6
humSensor1OutletStateturnOutletOn setting will turn the outlet/group on when the thresholds are breached and off when between the thresholds. turnOutletOff setting will turn the outlet/group off when the thresholds are breached and on when between the thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.2.1.7
contactClosureConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.3
contactClosure1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.3.1
contactClosure1NameDescriptive sensor namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.3.1.1
contactClosure1EnableWhen disabled, the sensor measurement is not displayed and the contact state is ignored.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.1.2
contactClosure1ControlOutletEnabled setting to control an outlet or group based on the contact state.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.1.3
contactClosure1OutletNameOutlet or group name to control based on the contact state.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.3.1.4
contactClosure1OutletStateturnOutletOn setting will turn the outlet/group on when the contact is closed and off when the contact is open. turnOutletOff setting will turn the outlet/group off when the contact is open and on when the contact is closed.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.1.5
contactClosure2
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.3.2
contactClosure2NameDescriptive sensor namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.3.2.1
contactClosure2EnableWhen disabled, the sensor measurement is not displayed and the contact state is ignored.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.2.2
contactClosure2ControlOutletEnabled setting to control an outlet or group based on the contact state.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.2.3
contactClosure2OutletNameOutlet or group name to control based on the contact state.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.3.2.4
contactClosure2OutletStateturnOutletOn setting will turn the outlet/group on when the contact is closed and off when the contact is open. turnOutletOff setting will turn the outlet/group off when the contact is open and on when the contact is closed.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.2.5
contactClosure3
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.3.3
contactClosure3NameDescriptive sensor namerw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.3.3.1
contactClosure3EnableWhen disabled, the sensor measurement is not displayed and the contact state is ignored.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.3.2
contactClosure3ControlOutletEnabled setting to control an outlet or group based on the contact state.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.3.3
contactClosure3OutletNameOutlet or group name to control based on the contact state.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.3.3.4
contactClosure3OutletStateturnOutletOn setting will turn the outlet/group on when the contact is closed and off when the contact is open. turnOutletOff setting will turn the outlet/group off when the contact is open and on when the contact is closed.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.3.3.5
outletSectionConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.4
outletSection1Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.4.1
outletSection1VoltageHighThresholdUpper threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.1.1
outletSection1VoltageLowThresholdLower threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.1.2
outletSection1CurrentHighThresholdUpper threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.1.3
outletSection1CurrentLowThresholdLower threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.1.4
outletSection1ControlOutletEnabled setting to control an outlet or group based on the section voltage and current thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.4.1.5
outletSection1OutletNameOutlet or group name to control based on the section voltage and current measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.4.1.6
outletSection2Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.4.2
outletSection2VoltageHighThresholdUpper threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.2.1
outletSection2VoltageLowThresholdLower threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.2.2
outletSection2CurrentHighThresholdUpper threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.2.3
outletSection2CurrentLowThresholdLower threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.2.4
outletSection2ControlOutletEnabled setting to control an outlet or group based on the section voltage and current thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.4.2.5
outletSection2OutletNameOutlet or group name to control based on the section voltage and current measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.4.2.6
outletSection3Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.4.3
outletSection3VoltageHighThresholdUpper threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.3.1
outletSection3VoltageLowThresholdLower threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.3.2
outletSection3CurrentHighThresholdUpper threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.3.3
outletSection3CurrentLowThresholdLower threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.3.4
outletSection3ControlOutletEnabled setting to control an outlet or group based on the section voltage and current thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.4.3.5
outletSection3OutletNameOutlet or group name to control based on the section voltage and current measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.4.3.6
outletSection4Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.4.4
outletSection4VoltageHighThresholdUpper threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.4.1
outletSection4VoltageLowThresholdLower threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.4.2
outletSection4CurrentHighThresholdUpper threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.4.3
outletSection4CurrentLowThresholdLower threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.4.4
outletSection4ControlOutletEnabled setting to control an outlet or group based on the section voltage and current thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.4.4.5
outletSection4OutletNameOutlet or group name to control based on the section voltage and current measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.4.4.6
outletSection5Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.4.5
outletSection5VoltageHighThresholdUpper threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.5.1
outletSection5VoltageLowThresholdLower threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.5.2
outletSection5CurrentHighThresholdUpper threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.5.3
outletSection5CurrentLowThresholdLower threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.5.4
outletSection5ControlOutletEnabled setting to control an outlet or group based on the section voltage and current thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.4.5.5
outletSection5OutletNameOutlet or group name to control based on the section voltage and current measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.4.5.6
outletSection6Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.4.6
outletSection6VoltageHighThresholdUpper threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.6.1
outletSection6VoltageLowThresholdLower threshold for section voltage measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.6.2
outletSection6CurrentHighThresholdUpper threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.6.3
outletSection6CurrentLowThresholdLower threshold for section current measurementrw
Integer32
.1.3.6.1.4.1.20677.2.8.4.6.4
outletSection6ControlOutletEnabled setting to control an outlet or group based on the section voltage and current thresholds.rw
Enumeration
.1.3.6.1.4.1.20677.2.8.4.6.5
outletSection6OutletNameOutlet or group name to control based on the section voltage and current measurement.rw
OCTET STRING
.1.3.6.1.4.1.20677.2.8.4.6.6
currentSensorValues
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.5
tempSensor1TempTemperature sensor measurement (units are indicated by the fahrenheitOrCelsius leaf under the unitConfig branch)ro
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.8.5.1
tempSensor2TempTemperature sensor measurement (units are indicated by the fahrenheitOrCelsius leaf under the unitConfig branch)ro
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.8.5.2
humSensor1HumidityHumidity sensor measurement (percent relative humidity)ro
Integer32
.1.3.6.1.4.1.20677.2.8.5.3
contactClosure1StateContact sensor statero
Enumeration
.1.3.6.1.4.1.20677.2.8.5.4
contactClosure2StateContact sensor statero
Enumeration
.1.3.6.1.4.1.20677.2.8.5.5
contactClosure3StateContact sensor statero
Enumeration
.1.3.6.1.4.1.20677.2.8.5.6
currentOutletSectionValues
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6
outletSection1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6.1
outletSection1VoltageVoltage measurement 1. This is either the section 1 voltage, the Line X-Y voltage, or the Phase X-N voltage, depending on the PDU hardware.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.1.1
outletSection1CurrentCurrent measurement 1. This is either the section 1 current or the Phase X current, depending on the PDU hardware.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.1.2
outletSection1VaSection 1 VA (or phase X VA, depending on the PDU hardware).ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.1.3
outletSection2
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6.2
outletSection2VoltageVoltage measurement 2. This is either the section 2 voltage, the Line Y-Z voltage, or the Phase Y-N voltage, depending on the PDU hardware.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.2.1
outletSection2CurrentCurrent measurement 2. This is either the section 2 current or the Phase Y current, depending on the PDU hardware.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.2.2
outletSection2VaSection 2 VA (or phase Y VA, depending on the PDU hardware).ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.2.3
outletSection3
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6.3
outletSection3VoltageVoltage measurement 3. This is either the section 3 voltage, the Line Z-X voltage, or the Phase Z-N voltage, depending on the PDU hardware.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.3.1
outletSection3CurrentCurrent measurement 3. This is either the section 3 current or the Phase Z current, depending on the PDU hardware.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.3.2
outletSection3VaSection 3 VA (or phase Z VA, depending on the PDU hardware).ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.3.3
total
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6.4
totalVoltageNoneroobsolete
Integer32
.1.3.6.1.4.1.20677.2.8.6.4.1
totalCurrentSum of current for all outlet sections (or phases)ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.4.2
totalVaTotal PDU VAro
Integer32
.1.3.6.1.4.1.20677.2.8.6.4.3
outletSection4
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6.5
outletSection4VoltageVoltage measurement 4 (section 4 voltage). This object will not be present if the PDU hardware measures Line-to-Line voltage or Phase voltage.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.5.1
outletSection4CurrentCurrent measurement 4. This is the section 4 current.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.5.2
outletSection4VaSection 4 VAro
Integer32
.1.3.6.1.4.1.20677.2.8.6.5.3
outletSection5
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6.6
outletSection5VoltageVoltage measurement 5 (section 5 voltage). This object will not be present if the PDU hardware measures Line-to-Line voltage or Phase voltage.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.6.1
outletSection5CurrentCurrent measurement 5. This is the section 5 current.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.6.2
outletSection5VaSection 5 VAro
Integer32
.1.3.6.1.4.1.20677.2.8.6.6.3
outletSection6
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.8.6.7
outletSection6VoltageVoltage measurement 6 (section 6 voltage). This object will not be present if the PDU hardware measures Line-to-Line voltage or Phase voltage.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.7.1
outletSection6CurrentCurrent measurement 6. This is the section 6 current.ro
Integer32
.1.3.6.1.4.1.20677.2.8.6.7.2
outletSection6VaSection 6 VAro
Integer32
.1.3.6.1.4.1.20677.2.8.6.7.3
events
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.9
notifyOutletStateOutlet state has changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.1
notifyCurrentThresholdCurrent measurement has exceeded a threshold or returned from crossing a threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.2
notifyVoltageThresholdVoltage measurement has exceeded a threshold or returned from crossing a threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.3
notifyTempSensorThresholdTemperature measurement has exceeded a threshold or returned from crossing a threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.4
notifyHumidSensorThresholdHumidity measurement has exceeded a threshold or returned from crossing a threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.5
notifyContactSensorThresholdContact sensor has changed state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.6
notifyUserLoginA user has logged in.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.7
notifyUserLogoutA user has logged out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.8
notifyFailedLoginA login failure occurred.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.9
notifyOutletWatchdogFailedAn outlet watchdog has failed and the corresponding outlet is being rebooted.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20677.2.9.10
eventInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.10
infoItemIdxNumerical index of the item that caused the notification. For example, if the notification was related to the state of outlet 5, this value will be 5 no matter what the customized outlet name is. Similarly, if the notification was related to a voltage threshold being exceeded for voltage measurement 2, this value will be 2.ro
Integer32
.1.3.6.1.4.1.20677.2.10.1
infoItemNameTextual name of the item that caused the notification. For example, if an outlet state change caused the notification, this will be the customized name of the outlet. If a voltage threshold caused the notification, this will be the fixed name of the voltage measurement (e.g., Line X-Y).ro
OCTET STRING
.1.3.6.1.4.1.20677.2.10.2
infoOutletStateThe new state of an outlet.ro
Enumeration
.1.3.6.1.4.1.20677.2.10.3
infoThresholdStateThe new state of a measurement that has upper and lower thresholds.ro
Enumeration
.1.3.6.1.4.1.20677.2.10.4
infoThresholdValueThe threshold which has been crossed.ro
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.10.5
infoMeasuredValueThe actual measured value.ro
Integer32 (-100..300)
.1.3.6.1.4.1.20677.2.10.6
infoContactStateThe new state of a contact switch sensor.ro
Enumeration
.1.3.6.1.4.1.20677.2.10.7
infoUserNameLogin name of a user.ro
OCTET STRING
.1.3.6.1.4.1.20677.2.10.8
conformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.25
compliancesThe requirements for conforming to the Switched ePDU MIB.
Unknown
.1.3.6.1.4.1.20677.2.25.1
oldCompliancesDeprecated requirements for conforming to the Switched ePDU MIB.deprecated
Unknown
.1.3.6.1.4.1.20677.2.25.2
obsoleteCompliancesObsoleted requirements for conforming to the Switched ePDU MIB.obsolete
Unknown
.1.3.6.1.4.1.20677.2.25.3
groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.20677.2.25.5
allObjectsThe object group.
Unknown
.1.3.6.1.4.1.20677.2.25.5.1
oldObjectsThe deprecated objects group.deprecated
Unknown
.1.3.6.1.4.1.20677.2.25.5.2
obsoleteObjectsThe obsoleted objects group.obsolete
Unknown
.1.3.6.1.4.1.20677.2.25.5.3
allNotificationsThe notifications group.
Unknown
.1.3.6.1.4.1.20677.2.25.5.4
EATON-EPDU-PU-SW-MIB - SNMP MIB Reference | MIBs Explorer