DNMSALARM-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for DNMSALARM-MIB.
9
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
9 total| Object Name |
|---|
dnmsAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.384.2.1 |
RFC1213-MIB Unknown .1.3.6.1.4.1.384.2.1 |
dnmsAlarmTrapAn SNMP Trap to encapsulate the Dynatech Communications
DN25 style alarms into an SNMP managed environment. TRAP-TYPE .1.3.6.1.4.1.384.2.1.0.1 |
dnmsAlarmEnableThe on/off switch for the dnms style alarms
as SNMP traps. When enabled, any condition that
would generate an alarm in the DynaTech proprietary
management systems would instead generate a SNMP
style trap.rw Enumeration .1.3.6.1.4.1.384.2.1.1 |
dnmsAlarmTableThe table of Dynatech proprietary alarms. SEQUENCE OF DnmsAlarmEntry .1.3.6.1.4.1.384.2.1.2 |
dnmsAlarmEntryAn entry for each of the Dynatech proprietary alarms
supported by the product. DnmsAlarmEntry .1.3.6.1.4.1.384.2.1.2.1 |
dnmsAlarmEntryIndexArbitrary number assigned to each alarm. Not all
CPX equipment will support all alarms.ro Enumeration .1.3.6.1.4.1.384.2.1.2.1.1 |
dnmsAlarmEntryEnableEach alarm can be enabled/disabled individually.
This is expected to matter more as equivalent SNMP
style traps are implemented in MIBS for CPX boxes.
The overlapping traps (e.g. rfc1215's linkDown and
linkUp overlapping the X25 link down and ups) could
result in superfluous trap messages. These can be
avoided by selectively disabling some of these
traps.rw Enumeration .1.3.6.1.4.1.384.2.1.2.1.2 |
dnmsAlarmEntryDescrTextual Description of the alarm condition.ro DisplayString .1.3.6.1.4.1.384.2.1.2.1.3 |